{"id":51718,"date":"2025-01-01T00:00:00","date_gmt":"2025-01-01T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/hplc-stationary-phases-to-have-in-your-toxicology-toolbox\/"},"modified":"2026-09-02T09:18:41","modified_gmt":"2026-09-02T09:18:41","slug":"hplc-stationary-phases-to-have-in-your-toxicology-toolbox","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/es\/blogs\/gnbl4710\/hplc-stationary-phases-to-have-in-your-toxicology-toolbox","title":{"rendered":"HPLC Stationary Phases to Have in Your Toxicology Toolbox"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">When it comes to stationary phases in HPLC, there are a ton of options to choose from. At Restek alone, we offer a catalog of 10+ stationary phases. Each of these phases has its own strengths, weaknesses, and capabilities depending on your intended analysis. When you start working on a new method, you might investigate several different stationary phases to see which one will best suit your list of analytes and their chemical properties. This will be especially important if that analyte list includes critical isomer pairs that need to be resolved.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In a toxicology lab setting, the scope of analytes will usually include drugs of abuse, therapeutic drugs, over the counter drugs, and alcohol metabolites. Varying polarities and structural differences can largely impact how analytes within these large scopes will interact with different stationary phases. Unfortunately, there is no \u201ccatch-all\u201d phase that can effectively analyze all the compounds involved in toxicology testing. Most often, method developers need to employ several different stationary phases to meet their analysis goals for different analyte classes. To find out which ones work for you, you could try them all out one by one\u2014or you can keep reading as we break down what stationary phases all toxicology labs should have in their method development toolbox.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">C18<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Most method developers see C18 columns as a \u201cgeneral-purpose\u201d or \u201cgo-to\u201d column in reversed-phase chromatography. This stationary phase is established, reliable, and is well-suited to handle the large, multi-drug class analyte lists that are common in toxicology testing. C18 phases work through hydrophobic interactions, which makes them a good choice when working with a large list of analytes that have varying polarities. While C18 phases can be used to analyze a wide range of compounds, they lack the selectivity needed to fully resolve some critical isomer pairs that have highly aromatic characteristics.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">There are some difficult separations, however, where the C18 is still a good fit. Differentiating between the d- and l-isomer forms of methamphetamine and amphetamine by LC-MS\/MS typically requires a chiral column, which are expensive and do not have broad utility. For labs that do not wish to go this route, this troublesome separation can be performed on a standard C18 column following a simple derivatization procedure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Even if C18 cannot separate every analyte in a toxicology testing scope, it is a crucial stationary phase that every method developer should have on hand.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> d- &amp; l- Amphetamines in urine on a Raptor C18 column. Both sets of enantiomers are baseline resolved without the use of a chiral column.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0737.png\" alt=\"d &amp; l Amphetamines (DNPA Derivatives) in Urine by LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0737<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion 1<\/th><th style=\"text-align: center;width: 75px\">Product Ion 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for l-Methamphetamine*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/537-46-2\/l-Methamphetamine\" target=\"_blank\" rel=\"noopener\">l-Methamphetamine*<\/a><\/td><td class=\"oth\">3.11<\/td><td class=\"oth\">400.3<\/td><td class=\"oth\">339.0<\/td><td class=\"oth\">323.8<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for d-Methamphetamine*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/537-46-2\/d-Methamphetamine\" target=\"_blank\" rel=\"noopener\">d-Methamphetamine*<\/a><\/td><td class=\"oth\">3.38<\/td><td class=\"oth\">400.3<\/td><td class=\"oth\">339.0<\/td><td class=\"oth\">323.8<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\">l-Amphetamine*<\/td><td class=\"oth\">4.16<\/td><td class=\"oth\">386.1<\/td><td class=\"oth\">325.0<\/td><td class=\"oth\">308.0<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for d-Amphetamine*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51-64-9\/d-Amphetamine\" target=\"_blank\" rel=\"noopener\">d-Amphetamine*<\/a><\/td><td class=\"oth\">4.55<\/td><td class=\"oth\">386.1<\/td><td class=\"oth\">325.0<\/td><td class=\"oth\">308.0<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">*Analytes are DNPA derivatives.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor C18  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9304A12\" rel=\"noopener\">cat.# 9304A12<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>Raptor C18 EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9304A0252\" rel=\"noopener\">cat.# 9304A0252<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>35 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>500 ng\/mL in urine<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>10 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>0.1% Formic acid in water <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>0.1% Formic acid in methanol <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.5<\/td><td>40<\/td><td>60<\/td><\/tr><tr><td>5.00<\/td><td>0.5<\/td><td>40<\/td><td>60<\/td><\/tr><tr><td>5.01<\/td><td>0.5<\/td><td>10<\/td><td>90<\/td><\/tr><tr><td>5.50<\/td><td>0.5<\/td><td>10<\/td><td>90<\/td><\/tr><tr><td>5.51<\/td><td>0.5<\/td><td>40<\/td><td>60<\/td><\/tr><tr><td>7.00<\/td><td>0.5<\/td><td>40<\/td><td>60<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>HPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>A 500 ng\/mL standard (d- and l-amphetamines and methamphetamines) was prepared in pooled urine. Fifty microliters of the standard was aliquoted into a microcentrifuge tube. Ten microliters of a working internal standard (20 \u00b5g\/mL (\u00b1)-amphetamine-D11 and (\u00b1)-methamphetamine-D11 in water) and 20 \u00b5L of 1M NaHCO<sub>3<\/sub> was added and vortexed at 3000 rpm for 10 seconds. After vortexing, 100 \u00b5L of 0.1% (w\/v) Marfey&#8217;s reagent (1-fluoro-2-4-dinitrophenyl-5-L-alanine amide) in acetone was added, vortexed, and heated at 45 \u00b0C for 1 hour. Samples were allowed to cool to room temperature before the addition of 40 \u00b5L of 1M HCl in water. The sample was then vortexed and evaporated to dryness under nitrogen at 45 \u00b0C. Samples were reconstituted in 1 mL of 40:60 water:methanol (v\/v) and filtered using Thomson SINGLE StEP standard filter vials cat.# 25893 prior to analysis.<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Thomson SINGLE StEP standard filter vials cat.# 25893 were used to produce this chromatogram, but have since been discontinued. For assistance choosing a replacement for this application, contact Restek Technical Service or your local Restek representative.<br \/><\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9304A0252<\/li><li>9304A12<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>d-AMP<\/li><li>d-MAMP<\/li><li>l-AMP<\/li><li>l-MAMP<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0737.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Strengths:<\/em> C18 is a versatile, established phase that can handle large lists of analytes with varying polarities.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Weaknesses:<\/em> C18 does not possess the selectivity to adequately resolve many critical isomer pairs in drugs of abuse testing.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Biphenyl<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">While not as widely used as C18, the Biphenyl stationary phase brings many advantages to the table for method developers. The Biphenyl phase\u2019s biggest strength is its ability to separate aromatic compounds, which makes it particularly adept at resolving critical isomer pairs. This enhanced selectivity comes from \u03c0-\u03c0 interactions between the electrons in the aromatic rings of the Biphenyl ligand and the \u03c0-electrons within the structures of the analytes of interest. The true potential of the Biphenyl phase is unlocked when used in conjunction with methanolic mobile phases, as the structure of methanol contains no \u03c0 electrons. This allows the \u03c0-\u03c0 interactions within the stationary phase to occur uninterrupted, resulting in improved separation. The Biphenyl stationary phase can resolve compounds that are difficult to separate or lack adequate retention on C18 or other phenyl phase columns. In some cases, the enhanced selectivity of the Biphenyl phase may also help to minimize matrix interferences.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> 18 Drugs of abuse in urine on a Raptor Biphenyl column. The critical isobars (morphine\/hydromorphone; codeine\/hydrocodone) are fully resolved from each other, as well as from matrix interferences present in human urine. When analyzed by C18 or other phenyl phase chemistries, early eluting isobaric compounds may experience poor resolution and peak shape.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0568.png\" alt=\"Pain Panel in Urine on Raptor Biphenyl (50 x 3.0 mm) by LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0568<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor ion<\/th><th style=\"text-align: center;width: 75px\">Product ion 1<\/th><th style=\"text-align: center;width: 75px\">Product ion 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Morphine*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57-27-2\/Morphine\" target=\"_blank\" rel=\"noopener\">Morphine*<\/a><\/td><td class=\"oth\">1.34<\/td><td class=\"oth\">286.2<\/td><td class=\"oth\">152.3<\/td><td class=\"oth\">165.3<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Oxymorphone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-41-5\/Oxymorphone\" target=\"_blank\" rel=\"noopener\">Oxymorphone<\/a><\/td><td class=\"oth\">1.40<\/td><td class=\"oth\">302.1<\/td><td class=\"oth\">227.3<\/td><td class=\"oth\">198.2<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hydromorphone*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/466-99-9\/Hydromorphone\" target=\"_blank\" rel=\"noopener\">Hydromorphone*<\/a><\/td><td class=\"oth\">1.52<\/td><td class=\"oth\">286.1<\/td><td class=\"oth\">185.3<\/td><td class=\"oth\">128.2<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Amphetamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/300-62-9\/Amphetamine\" target=\"_blank\" rel=\"noopener\">Amphetamine<\/a><\/td><td class=\"oth\">1.62<\/td><td class=\"oth\">136.0<\/td><td class=\"oth\">91.3<\/td><td class=\"oth\">119.2<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methamphetamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/537-46-2\/Methamphetamine\" target=\"_blank\" rel=\"noopener\">Methamphetamine<\/a><\/td><td class=\"oth\">1.84<\/td><td class=\"oth\">150.0<\/td><td class=\"oth\">91.2<\/td><td class=\"oth\">119.3<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Codeine*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-57-3\/Codeine\" target=\"_blank\" rel=\"noopener\">Codeine*<\/a><\/td><td class=\"oth\">1.91<\/td><td class=\"oth\">300.2<\/td><td class=\"oth\">165.4<\/td><td class=\"oth\">153.2<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Oxycodone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-42-6\/Oxycodone\" target=\"_blank\" rel=\"noopener\">Oxycodone<\/a><\/td><td class=\"oth\">2.02<\/td><td class=\"oth\">316.1<\/td><td class=\"oth\">241.3<\/td><td class=\"oth\">256.4<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hydrocodone*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/125-29-1\/Hydrocodone\" target=\"_blank\" rel=\"noopener\">Hydrocodone*<\/a><\/td><td class=\"oth\">2.06<\/td><td class=\"oth\">300.1<\/td><td class=\"oth\">199.3<\/td><td class=\"oth\">128.3<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norbuprenorphine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78715-23-8\/Norbuprenorphine\" target=\"_blank\" rel=\"noopener\">Norbuprenorphine<\/a><\/td><td class=\"oth\">2.59<\/td><td class=\"oth\">414.1<\/td><td class=\"oth\">83.4<\/td><td class=\"oth\">101.0<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor ion<\/th><th style=\"text-align: center;width: 75px\">Product ion 1<\/th><th style=\"text-align: center;width: 75px\">Product ion 2<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Meprobamate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57-53-4\/Meprobamate\" target=\"_blank\" rel=\"noopener\">Meprobamate<\/a><\/td><td class=\"oth\">2.61<\/td><td class=\"oth\">219.0<\/td><td class=\"oth\">158.4<\/td><td class=\"oth\">97.2<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fentanyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/437-38-7\/Fentanyl\" target=\"_blank\" rel=\"noopener\">Fentanyl<\/a><\/td><td class=\"oth\">2.70<\/td><td class=\"oth\">337.2<\/td><td class=\"oth\">188.4<\/td><td class=\"oth\">105.2<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Buprenorphine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52485-79-7\/Buprenorphine\" target=\"_blank\" rel=\"noopener\">Buprenorphine<\/a><\/td><td class=\"oth\">2.70<\/td><td class=\"oth\">468.3<\/td><td class=\"oth\">396.4<\/td><td class=\"oth\">414.5<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flurazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/17617-23-1\/Flurazepam\" target=\"_blank\" rel=\"noopener\">Flurazepam<\/a><\/td><td class=\"oth\">2.73<\/td><td class=\"oth\">388.2<\/td><td class=\"oth\">315.2<\/td><td class=\"oth\">288.3<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Sufentanil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56030-54-7\/Sufentanil\" target=\"_blank\" rel=\"noopener\">Sufentanil<\/a><\/td><td class=\"oth\">2.77<\/td><td class=\"oth\">387.2<\/td><td class=\"oth\">238.5<\/td><td class=\"oth\">111.3<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methadone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-99-3\/Methadone\" target=\"_blank\" rel=\"noopener\">Methadone<\/a><\/td><td class=\"oth\">2.86<\/td><td class=\"oth\">310.2<\/td><td class=\"oth\">265.3<\/td><td class=\"oth\">105.3<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carisoprodol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78-44-4\/Carisoprodol\" target=\"_blank\" rel=\"noopener\">Carisoprodol<\/a><\/td><td class=\"oth\">2.87<\/td><td class=\"oth\">261.2<\/td><td class=\"oth\">176.3<\/td><td class=\"oth\">158.1<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Lorazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/846-49-1\/Lorazepam\" target=\"_blank\" rel=\"noopener\">Lorazepam<\/a><\/td><td class=\"oth\">3.03<\/td><td class=\"oth\">321.0<\/td><td class=\"oth\">275.4<\/td><td class=\"oth\">303.1<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/439-14-5\/Diazepam\" target=\"_blank\" rel=\"noopener\">Diazepam<\/a><\/td><td class=\"oth\">3.31<\/td><td class=\"oth\">285.1<\/td><td class=\"oth\">193.2<\/td><td class=\"oth\">153.9<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">*An extracted ion chromatogram (XIC) of the isobars is presented in the inset.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor Biphenyl  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9309A5E\" rel=\"noopener\">cat.# 9309A5E<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>50 mm x 3.0 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>30 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Urine:mobile phase A:mobile phase B (17:76:7)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>10-100 ng\/mL<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>10 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water + 0.1% formic acid <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol + 0.1% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.6<\/td><td>90<\/td><td>10<\/td><\/tr><tr><td>1.50<\/td><td>0.6<\/td><td>55<\/td><td>45<\/td><\/tr><tr><td>2.50<\/td><td>0.6<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>3.70<\/td><td>0.6<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>3.71<\/td><td>0.6<\/td><td>90<\/td><td>10<\/td><\/tr><tr><td>5.00<\/td><td>0.6<\/td><td>90<\/td><td>10<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>AB SCIEX API 4000 MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Source:<\/th><td>TurboIonSpray<sup>&reg;<\/sup> <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>API LC-MS\/MS<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Lorazepam was prepared at 100 ng\/mL; all other analytes are 10 ng\/mL.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9309A5E<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>drug<\/li><li>drugs<\/li><li>drugs of abuse<\/li><li>illicit drugs<\/li><li>matrix<\/li><li>pain<\/li><li>pain control<\/li><li>pain drugs<\/li><li>pain management<\/li><li>pain management drugs<\/li><li>urine<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0568.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Strengths:<\/em> Biphenyl columns offer superior selectivity over C18 and other phenyl phase columns, allowing for the resolution of critical isomer pairs and matrix interferences.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Weaknesses:<\/em> Biphenyl is not as commonly used as C18, so method development may involve more optimization.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">FluoroPhenyl<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">For method developers working in a toxicology setting, the use C18 and Biphenyl phases is likely a familiar concept. In general, the compounds included in toxicology testing scopes can be successfully analyzed using a combination of C18 and Biphenyl columns. One of the exceptions to this is the analysis of cannabinoid isomers. Typical toxicological testing to determine cannabis use involves analyzing for the major psychoactive component in cannabis, \u03949-THC, and its two metabolites, 11-OH-\u03949-THC and \u03949-THC-COOH. The emergence of \u03948-THC, an isomer of \u03949-THC, has necessitated that labs also include this compound and its metabolites in their scope of testing. This updated compound list of six analytes includes three pairs of isomers which require full resolution for accurate reporting. C18 and Biphenyl columns do not exhibit the selectivity to adequately resolve all three pairs of isomers, but a FluoroPhenyl phase column does.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As we discussed earlier, C18 columns work through hydrophobic interactions and Biphenyl columns through \u03c0-\u03c0 interactions. FluoroPhenyl phases use both mechanisms in addition to dispersion, shape selectivity, cation exchange, and dipole interactions. By using multiple retention mechanisms, FluoroPhenyl phase columns are capable of unique separations. For toxicology labs that encounter THC isomers in their casework, a FluoroPhenyl column is a must for these tough separations.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong>\u00a0\u03948-THC, \u03949-THC, hydroxy- and carboxy-metabolites in whole blood on a Raptor FluoroPhenyl column. All three sets of isomers are fully resolved from each other to ensure accurate reporting.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0826.png\" alt=\"\u03949-THC; \u03948-THC; Hydroxy- and Carboxy- Metabolites in Whole Blood on Raptor FluoroPhenyl\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0826<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor<\/th><th style=\"text-align: center;width: 75px\">Product 1<\/th><th style=\"text-align: center;width: 75px\">Product 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 11-OH-\u03948-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/28646-40-4\/11-OH-\u03948-THC\" target=\"_blank\" rel=\"noopener\">11-OH-\u03948-THC<\/a><\/td><td class=\"oth\">4.66<\/td><td class=\"oth\">50<\/td><td class=\"oth\">331.0<\/td><td class=\"oth\">313.0<\/td><td class=\"oth\">201.1<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 11-OH-\u03949-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/34675-49-5\/11-OH-\u03949-THC\" target=\"_blank\" rel=\"noopener\">11-OH-\u03949-THC<\/a><\/td><td class=\"oth\">5.00<\/td><td class=\"oth\">50<\/td><td class=\"oth\">331.0<\/td><td class=\"oth\">313.0<\/td><td class=\"oth\">201.1<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03948-THC-COOH\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/39690-06-7\/\u03948-THC-COOH\" target=\"_blank\" rel=\"noopener\">\u03948-THC-COOH<\/a><\/td><td class=\"oth\">5.04<\/td><td class=\"oth\">250<\/td><td class=\"oth\">345.1<\/td><td class=\"oth\">327.0<\/td><td class=\"oth\">299.2<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03949-THC-COOH\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56354-06-4\/\u03949-THC-COOH\" target=\"_blank\" rel=\"noopener\">\u03949-THC-COOH<\/a><\/td><td class=\"oth\">5.85<\/td><td class=\"oth\">250<\/td><td class=\"oth\">345.1<\/td><td class=\"oth\">327.0<\/td><td class=\"oth\">299.2<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03948-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5957-75-5\/\u03948-THC\" target=\"_blank\" rel=\"noopener\">\u03948-THC<\/a><\/td><td class=\"oth\">10.88<\/td><td class=\"oth\">50<\/td><td class=\"oth\">315.0<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.2<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03949-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1972-08-3\/\u03949-THC\" target=\"_blank\" rel=\"noopener\">\u03949-THC<\/a><\/td><td class=\"oth\">11.26<\/td><td class=\"oth\">50<\/td><td class=\"oth\">315.0<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.2<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor FluoroPhenyl  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9319A1E\" rel=\"noopener\">cat.# 9319A1E<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 3 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>Raptor FluoroPhenyl EXP guard column cartridge 5 mm, 3 mm ID, 2.7 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9319A0253\" rel=\"noopener\">cat.# 9319A0253<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>\u03948-Tetrahydrocannabinol (\u03948-THC) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34090\" rel=\"noopener\">cat.# 34090<\/a>)<\/td><\/tr><tr><td><\/td><td>\u03949-Tetrahydrocannabinol (\u03949-THC) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34067\" rel=\"noopener\">cat.# 34067<\/a>)<\/td><\/tr><tr><td><\/td><td>(\u00b1)11-nor-9-carboxy-\u0394-9-THC (\u03949-THC-COOH) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34068\" rel=\"noopener\">cat.# 34068<\/a>)<\/td><\/tr><tr><td><\/td><td>Other compounds obtained separately. <\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>40:60 Water:methanol, both with 0.1% formic acid (v\/v)<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 0.1% formic acid <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol, 0.1% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.8<\/td><td>36<\/td><td>64<\/td><\/tr><tr><td>6.50<\/td><td>0.8<\/td><td>36<\/td><td>64<\/td><\/tr><tr><td>6.60<\/td><td>0.8<\/td><td>32<\/td><td>68<\/td><\/tr><tr><td>13.00<\/td><td>0.8<\/td><td>32<\/td><td>68<\/td><\/tr><tr><td>13.10<\/td><td>0.8<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>14.00<\/td><td>0.8<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>14.10<\/td><td>0.8<\/td><td>36<\/td><td>64<\/td><\/tr><tr><td>16.00<\/td><td>0.8<\/td><td>36<\/td><td>64<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Max Pressure:<\/th><td>390 bar<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Shimadzu 8045 MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Shimadzu Nexera X2<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Blank blood was spiked across the calibration range. Five hundred microliters of sample was added to a glass test tube. Fifty microliters of internal standard was added to each sample and vortexed. Samples were extracted by LLE. Five hundred microliters of HPLC grade water was added to each tube and vortexed. One hundred microliters of 10% acetic acid was added to each tube and vortexed. Two-and-a-half milliliters of 80:20 hexanes:ethyl acetate was added to each tube, capped, and vortexed until visibly combined. Samples were centrifuged at 2800 rpm for 15 minutes or until the two layers had completely separated. The supernatant was transferred to a clean test tube. Samples were dried down under nitrogen. Samples were reconstituted in 100 \u03bcL of 40:60 water:methanol, both with 0.1% formic acid, and vortexed. Samples were transferred to 2 mL short-cap, screw-thread vials (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21143\" rel=\"noopener\">cat.# 21143<\/a>) with glass vial inserts (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21776\" rel=\"noopener\">cat.# 21776<\/a>) and capped with short-cap, screw-thread closures (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/24498\" rel=\"noopener\">cat.# 24498<\/a>).<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>The column was stored in 100% acetonitrile when not in use. <\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34090<\/li><li>34067<\/li><li>34068<\/li><li>9319A0253<\/li><li>9319A1E<\/li><li>21143<\/li><li>21776<\/li><li>24498<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>FluoroPhenyl<\/li><li>THC Isomers<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0826.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Strengths:<\/em> FluoroPhenyl columns offer unique selectivity that can achieve the degree of separation needed for THC isomers in toxicology casework.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Weaknesses:<\/em> FluoroPhenyl columns may not provide an effective solution for analyzing large analyte lists like C18 and Biphenyl.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">EtG\/EtS<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">While the analysis of volatiles like ethanol is performed using gas chromatography (GC) methodologies, labs may also choose to monitor for the compounds ethyl glucuronide (EtG) and ethyl sulfate (EtS), which are biomarkers for monitoring alcohol use. The analysis of EtG and EtS can be performed by LC-MS\/MS, though there are some significant challenges associated with it. High polarity, matrix interferences, and analyte suppression all complicate this analysis. Many methods suffer from poor retention, co-elution with matrix interferences, and long run times. The Raptor EtG\/EtS column is a unique, proprietary phase developed by Restek specifically to combat these pain points. The EtG\/EtS column offers robust, consistent retention of both compounds and maintains resolution from matrix interferences. While this column does require some additional conditioning for the most optimized results, it offers a unique selectivity that any lab performing alcohol metabolite analysis should be sure to have.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4:<\/strong> EtG\/EtS in urine on a Raptor EtG\/EtS column. Both analytes are adequately retained on the column and are well resolved from matrix interferences.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0739.png\" alt=\"EtG\/EtS on Raptor EtG\/EtS: Updated Method Conditions (Mobile Phase and Gradient)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0739<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethyl-\u03b2-D-glucuronide-d5 (EtG-d5)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1135070-98-2\/Ethyl-\u03b2-D-glucuronide-d5\" target=\"_blank\" rel=\"noopener\">Ethyl-\u03b2-D-glucuronide-d5 (EtG-d5)<\/a><\/td><td class=\"oth\">1.21<\/td><td class=\"oth\">200<\/td><td class=\"oth\">226.2<\/td><td class=\"oth\">85.0<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethyl-\u03b2-D-glucuronide (EtG)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/17685-04-0\/Ethyl-\u03b2-D-glucuronide\" target=\"_blank\" rel=\"noopener\">Ethyl-\u03b2-D-glucuronide (EtG)<\/a><\/td><td class=\"oth\">1.23<\/td><td class=\"oth\">500<\/td><td class=\"oth\">221.2<\/td><td class=\"oth\">75.1<\/td><td class=\"oth\">85.1<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethyl sulfate-d5 (EtS-d5)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1329611-05-3\/Ethyl sulfate-d5\" target=\"_blank\" rel=\"noopener\">Ethyl sulfate-d5 (EtS-d5)<\/a><\/td><td class=\"oth\">2.36<\/td><td class=\"oth\">50<\/td><td class=\"oth\">130.1<\/td><td class=\"oth\">98.0<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethyl sulfate (EtS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/64-67-5\/Ethyl sulfate\" target=\"_blank\" rel=\"noopener\">Ethyl sulfate (EtS)<\/a><\/td><td class=\"oth\">2.38<\/td><td class=\"oth\">500<\/td><td class=\"oth\">125.1<\/td><td class=\"oth\">97.1<\/td><td class=\"oth\">80.0<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor EtG\/EtS  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9325A12\" rel=\"noopener\">cat.# 9325A12<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>UltraShield UHPLC precolumn filter, 0.2 \u03bcm frit (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/25809\" rel=\"noopener\">cat.# 25809<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>35 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>Ethyl-\u03b2-D-glucuronide-d5 (EtG-d5) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34102\" rel=\"noopener\">cat.# 34102<\/a>)<\/td><\/tr><tr><td><\/td><td>Ethyl-\u03b2-D-glucuronide (EtG) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34101\" rel=\"noopener\">cat.# 34101<\/a>)<\/td><\/tr><tr><td><\/td><td>Ethyl sulfate-d5 sodium salt (EtS-d5) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34104\" rel=\"noopener\">cat.# 34104<\/a>)<\/td><\/tr><tr><td><\/td><td>Ethyl sulfate sodium salt (EtS) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34103\" rel=\"noopener\">cat.# 34103<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>0.01% Formic acid in water<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>500 ng\/mL (40x acetonitrile precipitation sample prep)<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>10 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>0.01% Formic acid in water <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>0.1% Formic acid in acetonitrile <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.5<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>3.00<\/td><td>0.5<\/td><td>65<\/td><td>35<\/td><\/tr><tr><td>3.01<\/td><td>0.5<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>4.50<\/td><td>0.5<\/td><td>95<\/td><td>5<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Source:<\/th><td>Electrospray <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>HPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>A 500 ng\/mL standard was prepared in urine. A 50 \u03bcL aliquot was mixed with 10 \u03bcL of internal standard (20 \u03bcg\/mL EtG-d5 and 5 \u03bcg\/mL EtS-d5 in water) and 150 \u00b5L of acetonitrile by vortexing at 3000 rpm for 10 seconds and centrifuged at 4300 rpm for 10 minutes at 10 \u00b0C. After centrifugation, 100 \u00b5L of the supernatant was diluted with 900 \u00b5L (40x dilution) of 0.01% formic acid in water. The sample was then vortexed at 3000 rpm for 10 seconds and injected for LC-MS\/MS analysis.<br \/><\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34102<\/li><li>34101<\/li><li>34104<\/li><li>34103<\/li><li>25809<\/li><li>9325A12<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>EtG<\/li><li>EtS<\/li><li>Sensitivity<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0739.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Strengths:<\/em> This column offers unique selectivity specifically catered to the analysis of alcohol metabolites.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Weaknesses:<\/em> For optimal results, this column requires conditioning with matrix. See \u201c<a href=\"https:\/\/discover.restek.com\/articles\/CFAR3061\/successful-strategies-for-the-analysis-of-etg-and-ets-in-urine-01\/\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/articles\/CFAR3061\/successful-strategies-for-the-analysis-of-etg-and-ets-in-urine-01\/\">Successful Strategies for the Analysis of EtG and EtS in Urine<\/a>\u201d for more information. Additionally, this column has a specific intended use and is not amendable to large analyte lists.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Summary<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The list of compounds toxicology labs must test for can be extensive and contain analytes that have very different chemical properties. Most of these compounds will be successfully analyzed by using a combination of C18 and Biphenyl columns, which offer complementary selectivity. However, challenging separations like THC isomers and EtG\/EtS will require method developers to utilize alternative column chemistries like FluoroPhenyl or specialty phases like EtG\/EtS. While there is no perfect solution for all analytes, with these four HPLC stationary phases in your toxicology toolbox, you\u2019ll be in great shape to handle any separation that comes your way.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Products Mentioned<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A12\">                                Catalog No. 9304A12                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor C18, 2.7 \u00b5m, 100 x 2.1 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A12\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A0252\">                                Catalog No. 9304A0252                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor C18 EXP Guard Column Cartridge, 2.7 \u00b5m, 5 x 2.1 mm, 3-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A0252\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A5E\">                                Catalog No. 9309A5E                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Biphenyl, 2.7 \u00b5m, 50 x 3.0 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A5E\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A1E\">                                Catalog No. 9319A1E                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor FluoroPhenyl, 2.7 \u00b5m, 100 x 3.0 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A1E\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A0253\">                                Catalog No. 9319A0253                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor FluoroPhenyl EXP Guard Column Cartridge, 2.7 \u00b5m, 5 x 3.0 mm, 3-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A0253\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9325A12\">                                Catalog No. 9325A12                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor EtG\/EtS, 2.7 \u00b5m, 100 x 2.1 mm LC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9325A12\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25809\">                                Catalog No. 25809                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">UltraShield UHPLC PreColumn Filter, 0.2 \u00b5m Frit, ea.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25809\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34090\">                                Catalog No. 34090                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">delta 8-Tetrahydrocannabinol (Delta 8-THC) Standard, 1000 \u00b5g\/mL in P&amp;T Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34090\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34067\">                                Catalog No. 34067                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">delta 9-Tetrahydrocannabinol (Delta 9-THC) Standard, 1000 \u00b5g\/mL, P&amp;T Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34067\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34068\">                                Catalog No. 34068                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">(\u00b1)11-nor-9-carboxy-Delta-9-THC Standard, 100 \u00b5g\/mL, methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34068\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34102\">                                Catalog No. 34102                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Ethyl-beta-D-Glucuronide-d5 (EtG-d5) Standard, 1000 \u00b5g\/mL, Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34102\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34101\">                                Catalog No. 34101                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Ethyl-beta-D-Glucuronide (EtG) Standard, 1000 \u00b5g\/mL, Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34101\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34104\">                                Catalog No. 34104                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Ethyl Sulfate-d5 Sodium Salt (EtS-d5) Standard, 1000 \u00b5g\/mL, Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34104\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34103\">                                Catalog No. 34103                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Ethyl Sulfate Sodium Salt (EtS) Standard, 1000 \u00b5g\/mL, Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34103\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21143\">                                Catalog No. 21143                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Short-Cap Vial with Grad Marking Spot, 9-425 Screw-Thread, 2 mL, 9 mm, 12 x 32 (vial only), Amber, 1000-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21143\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21776\">                                Catalog No. 21776                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Vial Inserts, Glass, Big Mouth w\/Bottom Spring, 250 \u00b5L, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21776\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24498\">                                Catalog No. 24498                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Short Screw Cap, Polypropylene, Screw-Thread, PTFE\/Silicone\/PTFE Septa, Blue, Preassembled, 2.0 mL, 9 mm, 1000-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24498\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Find out which LC stationary phases are essential for toxicology labs. Here are the top four and why you need them.<\/p>\n","protected":false},"author":13,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[9],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[432],"class_list":["post-51718","post","type-post","status-publish","format-standard","hentry","category-blogs"],"acf":[],"taxonomy_info":{"category":[{"value":9,"label":"Blogs"}]},"featured_image_src_large":false,"author_info":{"display_name":"Haley Berkland, MS","author_link":"https:\/\/discover.restek.com\/es\/author\/haley-berkland-ms\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":9,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":432,"user_id":13,"is_guest":0,"slug":"haley-berkland-ms","display_name":"Haley Berkland, MS","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg"},"author_category":"1","first_name":"Haley","last_name":"Berkland","user_url":"https:\/\/www.linkedin.com\/in\/haley-berkland-60b66517b\/","job_title":"LC Applications Scientist","description":"Haley is an LC applications scientist at Restek. She attended Duquesne University, receiving her bachelor's degree in biochemistry and a master's degree in forensic science and law. As a graduate student, she performed research on the detection of drugs of abuse in vitreous humor by LC-MS\/MS. Before joining Restek in 2023, Haley spent four years working as a forensic toxicologist. While in this role, she performed analysis of postmortem toxicology casework, identification of seized drug evidence, and development\/validation of new assays by LC-MS\/MS, GC-MS, and GC-FID."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/51718","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/comments?post=51718"}],"version-history":[{"count":10,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/51718\/revisions"}],"predecessor-version":[{"id":102625,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/51718\/revisions\/102625"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media?parent=51718"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/categories?post=51718"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/tags?post=51718"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/industries-application?post=51718"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/post-badge?post=51718"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-type?post=51718"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/product-library?post=51718"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-technique?post=51718"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/ppma_author?post=51718"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}