{"id":51838,"date":"2014-03-06T13:30:00","date_gmt":"2014-03-06T13:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/troubleshooting-gc-syringe-issues-part-2\/"},"modified":"2026-08-11T17:04:20","modified_gmt":"2026-08-11T17:04:20","slug":"troubleshooting-gc-syringe-issues-part-2","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/es\/blogs\/gnbl4845\/troubleshooting-gc-syringe-issues-part-2","title":{"rendered":"Troubleshooting GC Syringe Issues \u2013 Part 2"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">In an earlier post titled <a href=\"https:\/\/discover.restek.com\/GNBL4844\/troubleshooting-gc-syringe-issues\/\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/blogs\/troubleshooting-gc-syringe-issues\">Troubleshooting GC Syringe Issues<\/a>&#8220;, I discussed several things to try if sticking plungers are the problem.&nbsp; In this post, I\u2019ll discuss what to do if the syringe is not pulling up the sample properly (or at all).<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"174\" height=\"100\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-troubleshooting-gc-syringe-issues-part-2-01.jpg\" alt=\"\" class=\"wp-image-17344\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">So what can cause a syringe to have problems pulling up a sample?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;The&nbsp;sample is too viscous.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If your sample is viscous, slow the plunger draw speed.&nbsp; Many autosamplers have this functionality.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If this still doesn\u2019t solve the issue, you may need to dilute your sample.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The&nbsp;syringe needle is plugged, or partially plugged.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Find out what is plugging your syringe needle.&nbsp; Is it the sample or septa?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If it is particles in your sample, you may need to add a filtering step before injecting.&nbsp;&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If you discover it is a piece of septum plugging your needle, try a different needle point style (Pt style #5 with side-hole are the least likely to plug).&nbsp;&nbsp;<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"148\" height=\"25\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-troubleshooting-gc-syringe-issues-part-2-02.jpg\" alt=\"\" class=\"wp-image-17350\" title=\"-\"><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\"><br role=\"presentation\" data-uw-rm-sr=\"\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;The&nbsp;plunger is not making a good seal with the syringe barrel.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">How worn is the syringe?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Eventually the plunger to barrel sealing performance of syringes degrades as it gets older and worn-out.&nbsp; This is especially true when using Gas-Tight syringes which have PTFE-tipped plungers.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tip:&nbsp; Never use a PTFE-tipped plunger which has not been prewetted with a solvent.&nbsp; When not in use, do not leave the plunger inside the syringe barrel.&nbsp; Instead, remove the plunger and store separately from the rest of the syringe.&nbsp; When needed, wet the PTFE tip before inserting into the syringe barrel.&nbsp;&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Most syringe manufacturers recommend that you do not use a plunger from one syringe in another (unless using Gas-Tight syringes where plungers are usually interchangeable).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">There&nbsp;is a leak between the needle and barrel.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If using a removable needle syringe, make sure the PTFE seal between the needle and barrel is installed properly and not worn out.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If using a fixed needle syringe, verify that the cement holding the needle to the barrel hasn\u2019t degraded.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The&nbsp;autosampler is not working properly.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Watch the autosampler as it tries to inject the sample.&nbsp; Is the autosampler programmed properly?&nbsp; Does it actually penetrate the sample vial deep enough to withdraw an aliquot?&nbsp; Does the autosampler actually lift the plunger?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hopefully one of these suggestions will help you out the next time your syringe is not pulling up a sample.&nbsp; Thanks for reading.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>In an earlier post titled Troubleshooting GC Syringe Issues, I discussed several things to try if sticking plungers are the problem. In this post, I&rsquo;ll discuss what to do if the syringe is not pulling up the sample properly (or&#8230;<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[2806],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2294],"ppma_author":[582],"class_list":["post-51838","post","type-post","status-publish","format-standard","hentry","category-blogs","resource-technique-gas-chromatography-gc"],"acf":[],"taxonomy_info":{"category":[{"value":2806,"label":"Blogs"}],"resource-technique":[{"value":2294,"label":"Gas Chromatography (GC)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Patrick Gallagher","author_link":"https:\/\/discover.restek.com\/es\/author\/patrick-gallagherrestek-com\/"},"comment_info":0,"category_info":[{"term_id":2806,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":2806,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":2806,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":582,"user_id":0,"is_guest":1,"slug":"alan-sensue","display_name":"Alan Sensue","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Alan","last_name":"Sensue","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/51838","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/comments?post=51838"}],"version-history":[{"count":7,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/51838\/revisions"}],"predecessor-version":[{"id":85510,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/51838\/revisions\/85510"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media?parent=51838"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/categories?post=51838"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/tags?post=51838"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/industries-application?post=51838"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/post-badge?post=51838"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-type?post=51838"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/product-library?post=51838"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-technique?post=51838"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/ppma_author?post=51838"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}