   {"id":58409,"date":"2020-02-28T21:38:00","date_gmt":"2020-02-28T21:38:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=58409"},"modified":"2026-01-22T14:39:22","modified_gmt":"2026-01-22T14:39:22","slug":"analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/es\/blogs-zh\/ffbl5257\/analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out","title":{"rendered":"Analyzing avocado: How to deal with lack of water and keep the fats out"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Avocados are a popular produce item. In fact, the consumption of avocados rose by 450% since&nbsp;<a href=\"https:\/\/www.statista.com\/statistics\/591263\/average-avocado-consumption-us-per-week\/\" target=\"_blank\" rel=\"noopener\">2000<\/a>! Avocado may be delicious, but it is difficult to deal with in the lab. The good news \u2013 avocados are ranked number 1 on the&nbsp;<a href=\"https:\/\/www.ewg.org\/foodnews\/clean-fifteen.php\" target=\"_blank\" rel=\"noopener\">clean 15 list<\/a>, meaning they have the least amount of pesticide residues. With so many avocados on the market, the testing is as important as ever, which may not be that easy. Avocados are a commodity that consists of approximately 70% water and 15 % fat. High-fat content and a lack of water mean adjustments must be made in order to ensure accurate pesticide residue results. Here, we explore several QuEChERS extraction and cleanup options and present a recommended approach.&nbsp; For GC-MS\/MS analysis, most of the fat needs to be removed because excess fat can lead to poor analyte recoveries and an increase in instrument maintenance.<\/p>\n\n\n<style>.kb-image58409_393840-e9 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image58409_393840-e9\"><figure class=\"aligncenter size-medium_large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"512\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-01-768x512.jpg\" alt=\"\" class=\"kb-img wp-image-58425\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-01-768x512.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-01-300x200.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-01-1024x683.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-01.jpg 1050w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><figcaption>Image source: https:\/\/daily.jstor.org\/the-illustrious-history-of-the-avocado\/<\/figcaption><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Fats can be removed during extraction by using a non-polar solvent such as hexane. This approach can be used in junction with QuEChERS, but there is a caveat. Unfortunately, using hexane with QuEChERS may lead to analyte loss since some of the pesticide residues are also non-polar and could be dissolved in the hexane with the fats. Because I\u2019m analyzing avocados by GC-MS\/MS, this would be a problem, so that leaves us with \u201cjust\u201d regular QuEChERS. Due to its low water content, avocado needs to be hydrated before the extraction. There are two ways to accomplish this: the first is to add enough water to already homogenized avocados to get 10 mL of total water content, i.e. 3 mL for every 10 g of avocados; the second approach is taken from&nbsp;<a href=\"https:\/\/www.en-standard.eu\/bs-en-15662-2018-foods-of-plant-origin-multimethod-for-the-determination-of-pesticide-residues-using-gc-and-lc-based-analysis-following-acetonitrile-extraction-partitioning-and-clean-up-by-dispersive-spe-modular-quechers-method\/?gclid=Cj0KCQiAkePyBRCEARIsAMy5ScsUB_oJNWH2qFBbVpGMzumlVbPksFMq4K27A4AsRY301Q7Fb_mMV_UaAgHlEALw_wcB\" target=\"_blank\" rel=\"noopener\">EN method 15662:2018<\/a>&nbsp;and is for commodities with intermediate water content (40-80%) and high matrix load or high oil content (&gt;5%). This method samples 5 grams of commodity and adds 6 mL of water, which is then extracted with 10 mL of acetonitrile (ACN). As in my previous blogs, I used the&nbsp;QuEChERS performance mix&nbsp;to compare these two methods. For this comparison I used the&nbsp;EN method salts&nbsp;(Fig 2).<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\">Figure 2: Comparison of pesticide recoveries (area\/area of internal standard) with two extraction methods. Method 1: 10 g avocados and 3 mL water; method 2: 5 g avocados and 6 mL water.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image58409_9c0610-a1 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image58409_9c0610-a1\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"396\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-02.png\" alt=\"\" class=\"kb-img wp-image-58431\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-02.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-02-300x116.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-02-768x297.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">While the first method (10 g of avocados and 3 mL water) had better recoveries for some pesticide residues, the&nbsp;<a href=\"https:\/\/www.en-standard.eu\/bs-en-15662-2018-foods-of-plant-origin-multimethod-for-the-determination-of-pesticide-residues-using-gc-and-lc-based-analysis-following-acetonitrile-extraction-partitioning-and-clean-up-by-dispersive-spe-modular-quechers-method\/?gclid=Cj0KCQiAkePyBRCEARIsAMy5ScsUB_oJNWH2qFBbVpGMzumlVbPksFMq4K27A4AsRY301Q7Fb_mMV_UaAgHlEALw_wcB\" target=\"_blank\" rel=\"noopener\">EN method 15662:2018<\/a>&nbsp;(5 g&nbsp; avocados and 6 mL water) method had better overall recoveries (Fig 2). Next, I compared the&nbsp;EN, Original, and AOAC salts&nbsp;following the same ratio of water and avocados, i.e. 6 ml and 5 g for the EN and original unbuffered methods and 9 ml and 7.5 g for the AOAC method (Fig 3).<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\">Figure 3: Comparison of pesticide recoveries (area\/area of internal standard) with different extraction salts.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image58409_c0a1cc-87 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image58409_c0a1cc-87\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"377\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-03.png\" alt=\"\" class=\"kb-img wp-image-58437\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-03.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-03-300x110.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-03-768x283.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The recoveries (area\/area of internal standard) were comparable, however, if we normalize them to the EN salts results, the AOAC salts have the highest maximum and mean recovery (Table 1).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Table 1: Comparison of pesticide recoveries with different extraction salt (normalized to EN salts)<\/p>\n\n\n<style>.kb-image58409_2df3f6-0f:not(.kb-image-is-ratio-size) .kb-img, .kb-image58409_2df3f6-0f.kb-image-is-ratio-size{padding-top:var(--global-kb-spacing-xs, 1rem);padding-bottom:var(--global-kb-spacing-sm, 1.5rem);}.kb-image58409_2df3f6-0f .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image58409_2df3f6-0f size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"721\" height=\"180\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-04.png\" alt=\"\" class=\"kb-img wp-image-58443\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-04.png 721w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-04-300x75.png 300w\" sizes=\"auto, (max-width: 721px) 100vw, 721px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Because we still need to remove the oils, the selection of dSPE is crucial. The end-capped C18 (EC-C18) containing dSPE is designed to remove the remaining fats. With this in mind, I compared four different dSPE tubes which varied by their PSA, EC-C18, and GCB (graphitized carbon black) content (Table 2, Fig 4).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Table 1: Comparison of pesticide recoveries with different extraction salt (normalized to EN salts)<\/p>\n\n\n<style>.kb-image58409_7322a2-86:not(.kb-image-is-ratio-size) .kb-img, .kb-image58409_7322a2-86.kb-image-is-ratio-size{padding-top:var(--global-kb-spacing-xs, 1rem);padding-bottom:var(--global-kb-spacing-xs, 1rem);}.kb-image58409_7322a2-86 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image58409_7322a2-86 size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"979\" height=\"293\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-05.png\" alt=\"\" class=\"kb-img wp-image-58449\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-05.png 979w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-05-300x90.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-05-768x230.png 768w\" sizes=\"auto, (max-width: 979px) 100vw, 979px\" \/><\/figure>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\">Figure 4: Comparison of pesticide recoveries (area\/area of internal standard) with different dSPE clean-up. See Table 4 for dSPE content.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image58409_ede761-69 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image58409_ede761-69\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"864\" height=\"352\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-06.png\" alt=\"\" class=\"kb-img wp-image-58455\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-06.png 864w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-06-300x122.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analyzing-avocado-how-to-deal-with-lack-of-water-and-keep-the-fats-out-06-768x313.png 768w\" sizes=\"auto, (max-width: 864px) 100vw, 864px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">From the comparison of the recoveries in figure 4, we can immediately notice that dSPE&nbsp;#26219&nbsp;has significantly higher recoveries for 2-phenylphenol, malathion, and myclobutanil, but, has much lower recoveries for cyprodinil, chlorpyrifos, and thiabendazole. This means&nbsp;#26219&nbsp;is not a suitable candidate for this analysis. The other dSPE tubes have much more similar responses, with slightly better recoveries for&nbsp;#26125. The dSPE&nbsp;#26242&nbsp;has similar recoveries to dSPE #26125, but the absence of PSA (Table 2) may cause trouble with a wider range of pesticides.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To summarize, for my further pesticide work I chose to work with&nbsp;AOAC salts&nbsp;with an adjusted ratio of avocados to water (7.5 g to 9 mL) using&nbsp;#26125&nbsp;dSPE.<\/p>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Products Mentioned<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26125\">                                Catalog No. 26125                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Q-sep QuEChERS dSPE 2 mL Centrifuge Tube, Contains 150 mg MgSO4, 50 mg PSA, 50 mg C18-EC, 100 Tubes<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26125\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Avocados are a popular produce item. In fact, the consumption of avocados rose by 450% since 2000! Avocado may be delicious, but it is difficult to deal with in the lab. The good news \u2013 avocados are ranked number 1&#8230;<\/p>\n","protected":false},"author":50,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[790],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[591],"class_list":["post-58409","post","type-post","status-publish","format-standard","hentry","category-blogs-zh"],"acf":[],"taxonomy_info":{"category":[{"value":790,"label":"\u535a\u5ba2"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jana Hepner, PhD","author_link":"https:\/\/discover.restek.com\/es\/author\/jana-hepner-phd\/"},"comment_info":0,"category_info":[{"term_id":790,"name":"\u535a\u5ba2","slug":"blogs-zh","term_group":0,"term_taxonomy_id":790,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":790,"category_count":457,"category_description":"","cat_name":"\u535a\u5ba2","category_nicename":"blogs-zh","category_parent":0}],"tag_info":false,"authors":[{"term_id":591,"user_id":50,"is_guest":0,"slug":"jana-hepner-phd","display_name":"Jana Hepner, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hepner-jana.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hepner-jana.jpg"},"author_category":"1","first_name":"Jana","last_name":"Hepner","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/58409","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/users\/50"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/comments?post=58409"}],"version-history":[{"count":8,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/58409\/revisions"}],"predecessor-version":[{"id":76213,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/58409\/revisions\/76213"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media?parent=58409"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/categories?post=58409"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/tags?post=58409"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/industries-application?post=58409"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/post-badge?post=58409"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-type?post=58409"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/product-library?post=58409"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-technique?post=58409"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/ppma_author?post=58409"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}