{"id":60747,"date":"2025-11-07T14:25:37","date_gmt":"2025-11-07T14:25:37","guid":{"rendered":"https:\/\/discover.restek.com\/?p=60747"},"modified":"2026-08-11T18:43:09","modified_gmt":"2026-08-11T18:43:09","slug":"the-evolving-landscape-of-thc-drug-testing-delta-8-vs-delta-9-2","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/es\/posters-presentations-fr\/gnot5313\/the-evolving-landscape-of-thc-drug-testing-delta-8-vs-delta-9-2","title":{"rendered":"The Evolving Landscape of THC Drug Testing, Delta-8 vs. Delta-9"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">When performing drug testing for THC, the carboxy metabolite is historically the analyte used to determine cannabis usage. This compound is detectable in urine or blood for several weeks, but it can be challenging to determine if a user is intoxicated at the time of testing. Labs may be interested in testing for the hydroxy metabolite, the intermediate between THC and the carboxy metabolite. This intermediate is useful in determining time of consumption. Delta8-THC is an isomer of delta9-THC that also has psychoactive effects. Chromatographic separation of delta8\/9-THC and their respective metabolites is required due to their nearly identical structures. Three column chemistries were investigated in this study for the analysis of delta8\/9-THC and their metabolites. Biphenyl, ARC-18, and FluoroPhenyl stationary phases were tested on a 100 x 2.1 mm column dimension using water and methanol as mobile phases, both modified with 0.1% formic acid. The FluoroPhenyl column shows great selectivity for the target analytes and resolved all three pairs of isomers with a 12-minute cycle time. This method could be used to determine THC isomers and metabolite levels in biological fluids.<\/p>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/discover.restek.com\/wp-content\/uploads\/poster-pittcon-2024-The-Evolving-Landscape-of-THC-Drug-testing.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"Embed of poster-pittcon-2024-The Evolving Landscape of THC Drug testing.\"><\/object><a id=\"wp-block-file--media-24d1021d-b5dd-4bcf-85e5-da65bb67ae54\" href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/poster-pittcon-2024-The-Evolving-Landscape-of-THC-Drug-testing.pdf\">poster-pittcon-2024-The Evolving Landscape of THC Drug testing<\/a><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/poster-pittcon-2024-The-Evolving-Landscape-of-THC-Drug-testing.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-24d1021d-b5dd-4bcf-85e5-da65bb67ae54\">Download<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>When performing drug testing for THC, the carboxy metabolite is historically the analyte used to determine cannabis usage. This compound is detectable in urine or blood for several weeks, but it can be challenging to determine if a user is intoxicated at the time of testing. Labs may be interested in testing for the hydroxy metabolite, the intermediate between THC and the carboxy metabolite. This intermediate is useful in determining time of consumption. Delta8-THC is an isomer of delta9-THC that also has psychoactive effects. Chromatographic separation of delta8\/9-THC and their respective metabolites is required due to their nearly identical structures. Three column chemistries were investigated in this study for the analysis of delta8\/9-THC and their metabolites. Biphenyl, ARC-18, and FluoroPhenyl stationary phases were tested on a 100 x 2.1 mm column dimension using water and methanol as mobile phases, both modified with 0.1% formic acid. The FluoroPhenyl column shows great selectivity for the target analytes and resolved all three pairs of isomers with a 12-minute cycle time. This method could be used to determine THC isomers and metabolite levels in biological fluids.<\/p>\n","protected":false},"author":47,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[812],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[579,432],"class_list":["post-60747","post","type-post","status-publish","format-standard","hentry","category-posters-presentations-fr"],"acf":[],"taxonomy_info":{"category":[{"value":812,"label":"Posters &amp; Presentations"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jamie L. York, PhD","author_link":"https:\/\/discover.restek.com\/es\/author\/jamie-l-york-phd\/"},"comment_info":0,"category_info":[{"term_id":812,"name":"Posters &amp; Presentations","slug":"posters-presentations-fr","term_group":0,"term_taxonomy_id":812,"taxonomy":"category","description":"","parent":0,"count":125,"filter":"raw","cat_ID":812,"category_count":125,"category_description":"","cat_name":"Posters &amp; Presentations","category_nicename":"posters-presentations-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":579,"user_id":47,"is_guest":0,"slug":"jamie-l-york-phd","display_name":"Jamie L. York, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/york-jamie-1000x1000-1-e1765483005988.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/york-jamie-1000x1000-1-e1765483005988.jpg"},"author_category":"1","first_name":"Jamie","last_name":"York","user_url":"https:\/\/www.linkedin.com\/in\/jamielyork\/","job_title":"Principal Scientist, LC Solutions","description":"Jamie York is a principal scientist in the Applications Lab at Restek Corporation. She leads the development of innovative analytical methods tailored to the food, clinical, environmental, and cannabis markets. Jamie earned her PhD in chemistry from The University of Texas at Arlington, where she gained extensive expertise in a range of analytical techniques, including gas chromatography\u2013vacuum ultraviolet (GC\u2013VUV); gas chromatography\u2013mass spectrometry (GC\u2013MS); matrix-assisted laser desorption\/ionization (MALDI); and liquid chromatography\u2013 mass spectrometry (LC\u2013MS\/MS); with a research emphasis on food and environmental analysis. Today, her work focuses on complex method development and advanced sample preparation strategies to support the evolving needs of the scientific community."},{"term_id":432,"user_id":13,"is_guest":0,"slug":"haley-berkland-ms","display_name":"Haley Berkland, MS","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg"},"author_category":"1","first_name":"Haley","last_name":"Berkland","user_url":"https:\/\/www.linkedin.com\/in\/haley-berkland-60b66517b\/","job_title":"LC Applications Scientist","description":"Haley is an LC applications scientist at Restek. She attended Duquesne University, receiving her bachelor's degree in biochemistry and a master's degree in forensic science and law. As a graduate student, she performed research on the detection of drugs of abuse in vitreous humor by LC-MS\/MS. Before joining Restek in 2023, Haley spent four years working as a forensic toxicologist. While in this role, she performed analysis of postmortem toxicology casework, identification of seized drug evidence, and development\/validation of new assays by LC-MS\/MS, GC-MS, and GC-FID."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/60747","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/users\/47"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/comments?post=60747"}],"version-history":[{"count":1,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/60747\/revisions"}],"predecessor-version":[{"id":60749,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/60747\/revisions\/60749"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media?parent=60747"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/categories?post=60747"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/tags?post=60747"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/industries-application?post=60747"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/post-badge?post=60747"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-type?post=60747"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/product-library?post=60747"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-technique?post=60747"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/ppma_author?post=60747"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}