{"id":60791,"date":"2025-11-07T15:06:49","date_gmt":"2025-11-07T15:06:49","guid":{"rendered":"https:\/\/discover.restek.com\/?p=60791"},"modified":"2026-01-08T14:22:13","modified_gmt":"2026-01-08T14:22:13","slug":"simultaneous-determination-of-alternaria-toxins-ergot-alkaloid-epimers-and-other-major-mycotoxins-in-various-food-matrices-by-lc-ms-ms-3","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/es\/posters-presentations\/gnot5324\/simultaneous-determination-of-alternaria-toxins-ergot-alkaloid-epimers-and-other-major-mycotoxins-in-various-food-matrices-by-lc-ms-ms-3","title":{"rendered":"Simultaneous Determination of Alternaria Toxins, Ergot Alkaloid Epimers, and Other Major Mycotoxins in Various Food Matrices by LC-MS\/MS"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Various food commodities are vulnerable to different types of fungal pathogens and could be contaminated with differential classes of mycotoxins as a result. It is ideal to implement a generic method for simultaneous determination of multi-mycotoxins in different food matrices or agricultural products. In this study, a simplified sample preparation procedure and a reliable LC-MS\/MS analytical method were developed for comprehensive measurement of 37 regulated and emerging mycotoxins, including 5 Alternaria toxins, 6 major ergot alkaloids, and their corresponding epimers. Four different food matrices (baby wheat cereal, peanut, tomato puree, and blended flour) were chosen for method validation to demonstrate the applicability of this analytical method to a wide range of food types. Sample extraction was performed using a formic acid-acidified 80:20 acetonitrile:water solution followed by extract dry down and reconstitution in a 50:50 water:methanol solution for injection analysis on a biphenyl LC column. Chromatographic analysis was performed using MS friendly acidic mobile phases and completed with a short 11-minute cycling time for proper separation of ergot alkaloid epimers. Method accuracy and precision were evaluated by fortification of food samples at 3 different levels. Accurate quantification was achieved using matrix-matched calibration standards at the range of 0.4 to 400 \u00b5g\/kg. The recoveries of all mycotoxins (except citrinin) in fortified samples were from 70% to 120%, and the relative standard deviation was less than 20%. The established workflow was simple and fast for multi-mycotoxin determination with a unique benefit of simultaneous analysis of Alternaria toxins and ergot alkaloids.<\/p>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/discover.restek.com\/wp-content\/uploads\/poster-aoac-2022-simultaneous-determination-of-alternaria-toxins-ergot-alkaloid-epimers-and-other-major-mycotoxins-in-various-food-matrices-.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"Embed of poster-aoac-2022-simultaneous-determination-of-alternaria-toxins-ergot-alkaloid-epimers-and-other-major-mycotoxins-in-various-food-matrices-.\"><\/object><a id=\"wp-block-file--media-d37ae997-bff9-4a0b-8dab-c4fb0427a92e\" href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/poster-aoac-2022-simultaneous-determination-of-alternaria-toxins-ergot-alkaloid-epimers-and-other-major-mycotoxins-in-various-food-matrices-.pdf\">poster-aoac-2022-simultaneous-determination-of-alternaria-toxins-ergot-alkaloid-epimers-and-other-major-mycotoxins-in-various-food-matrices-<\/a><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/poster-aoac-2022-simultaneous-determination-of-alternaria-toxins-ergot-alkaloid-epimers-and-other-major-mycotoxins-in-various-food-matrices-.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-d37ae997-bff9-4a0b-8dab-c4fb0427a92e\">Download<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Various food commodities are vulnerable to different types of fungal pathogens and could be contaminated with differential classes of mycotoxins as a result. It is ideal to implement a generic method for simultaneous determination of multi-mycotoxins in different food matrices or agricultural products. In this study, a simplified sample preparation procedure and a reliable LC-MS\/MS analytical method were developed for comprehensive measurement of 37 regulated and emerging mycotoxins, including 5 Alternaria toxins, 6 major ergot alkaloids, and their corresponding epimers. Four different food matrices (baby wheat cereal, peanut, tomato puree, and blended flour) were chosen for method validation to demonstrate the applicability of this analytical method to a wide range of food types. Sample extraction was performed using a formic acid-acidified 80:20 acetonitrile:water solution followed by extract dry down and reconstitution in a 50:50 water:methanol solution for injection analysis on a biphenyl LC column. Chromatographic analysis was performed using MS friendly acidic mobile phases and completed with a short 11-minute cycling time for proper separation of ergot alkaloid epimers. Method accuracy and precision were evaluated by fortification of food samples at 3 different levels. Accurate quantification was achieved using matrix-matched calibration standards at the range of 0.4 to 400 \u00b5g\/kg. The recoveries of all mycotoxins (except citrinin) in fortified samples were from 70% to 120%, and the relative standard deviation was less than 20%. The established workflow was simple and fast for multi-mycotoxin determination with a unique benefit of simultaneous analysis of Alternaria toxins and ergot alkaloids.<\/p>\n","protected":false},"author":46,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[12],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[578,579,593,589,702],"class_list":["post-60791","post","type-post","status-publish","format-standard","hentry","category-posters-presentations"],"acf":[],"taxonomy_info":{"category":[{"value":12,"label":"Posters &amp; Presentations"}]},"featured_image_src_large":false,"author_info":{"display_name":"Shun-Hsin Liang, PhD","author_link":"https:\/\/discover.restek.com\/es\/author\/shun-hsin-liang-phd\/"},"comment_info":0,"category_info":[{"term_id":12,"name":"Posters &amp; Presentations","slug":"posters-presentations","term_group":0,"term_taxonomy_id":12,"taxonomy":"category","description":"","parent":0,"count":125,"filter":"raw","cat_ID":12,"category_count":125,"category_description":"","cat_name":"Posters &amp; Presentations","category_nicename":"posters-presentations","category_parent":0}],"tag_info":false,"authors":[{"term_id":578,"user_id":46,"is_guest":0,"slug":"shun-hsin-liang-phd","display_name":"Shun-Hsin Liang, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-liang-shun-hsin-e1765414149534.png","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-liang-shun-hsin-e1765414149534.png"},"author_category":"1","first_name":"Shun-Hsin","last_name":"Liang","user_url":"https:\/\/www.linkedin.com\/in\/shun-hsin-liang-174423123\/","job_title":"Senior Principal Scientist, LC Solution","description":"Shun-Hsin is a senior principal scientist in LC Solutions at Restek. He received his bachelor\u2019s degree from the National Taiwan University in 1988 and obtained his PhD from Michigan State University in 1996. He performed postdoctoral research at the University of Michigan from 1996 to 2000 for oncology studies. In 2001, he was appointed as research faculty at The Pennsylvania State University and focused on molecular toxicology research. In 2006, he joined MPI Research Inc. as a senior research scientist and was a study director for GLP analytical projects. In 2013, Dr. Liang joined the LC Solutions department at Restek and specialized in developing application methods across the fields of environmental, food safety, and life sciences."},{"term_id":579,"user_id":47,"is_guest":0,"slug":"jamie-l-york-phd","display_name":"Jamie L. York, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/york-jamie-1000x1000-1-e1765483005988.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/york-jamie-1000x1000-1-e1765483005988.jpg"},"author_category":"1","first_name":"Jamie","last_name":"York","user_url":"https:\/\/www.linkedin.com\/in\/jamielyork\/","job_title":"Principal Scientist, LC Solutions","description":"Jamie York is a principal scientist in the Applications Lab at Restek Corporation. She leads the development of innovative analytical methods tailored to the food, clinical, environmental, and cannabis markets. Jamie earned her PhD in chemistry from The University of Texas at Arlington, where she gained extensive expertise in a range of analytical techniques, including gas chromatography\u2013vacuum ultraviolet (GC\u2013VUV); gas chromatography\u2013mass spectrometry (GC\u2013MS); matrix-assisted laser desorption\/ionization (MALDI); and liquid chromatography\u2013 mass spectrometry (LC\u2013MS\/MS); with a research emphasis on food and environmental analysis. Today, her work focuses on complex method development and advanced sample preparation strategies to support the evolving needs of the scientific community."},{"term_id":593,"user_id":0,"is_guest":1,"slug":"joe-konschnik","display_name":"Joe Konschnik","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-konschnik-joe.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-konschnik-joe.jpg"},"author_category":"1","first_name":"Joe","last_name":"Konschnik","user_url":"","job_title":"","description":""},{"term_id":589,"user_id":49,"is_guest":0,"slug":"hansjoerg-majer","display_name":"Hansj\u00f6rg Majer, PhD","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Hansj\u00f6rg","last_name":"Majer, PhD","user_url":"","job_title":"","description":""},{"term_id":702,"user_id":0,"is_guest":1,"slug":"justin-steimling","display_name":"Justin Steimling","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Justin","last_name":"Steimling","user_url":"https:\/\/www.linkedin.com\/in\/justin-steimling-959729167\/","job_title":"R&D, LC Solutions","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/60791","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/users\/46"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/comments?post=60791"}],"version-history":[{"count":1,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/60791\/revisions"}],"predecessor-version":[{"id":60793,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/60791\/revisions\/60793"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media?parent=60791"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/categories?post=60791"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/tags?post=60791"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/industries-application?post=60791"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/post-badge?post=60791"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-type?post=60791"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/product-library?post=60791"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-technique?post=60791"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/ppma_author?post=60791"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}