{"id":61373,"date":"2026-01-19T19:42:04","date_gmt":"2026-01-19T19:42:04","guid":{"rendered":"https:\/\/discover.restek.com\/?p=61373"},"modified":"2026-04-02T17:35:45","modified_gmt":"2026-04-02T17:35:45","slug":"increase-lab-efficiency-with-an-expanded-trace-level-semivolatiles-method","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/es\/articles\/evfa5253\/increase-lab-efficiency-with-an-expanded-trace-level-semivolatiles-method","title":{"rendered":"Increase Lab Efficiency with an Expanded Trace-Level Semivolatiles Method"},"content":{"rendered":"\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Groundbreaking TriMax deactivation creates a robust and exceptionally inert sample flow path for 150 compounds, including acids, bases, and neutrals.<\/li>\n\n\n\n<li>Maximum inertness improves peak shape for a wide range of semivolatiles, allowing method consolidation and picogram-level sensitivity.<\/li>\n\n\n\n<li>More flexibility\u2014implement our method for 150 semivolatiles or optimize conditions for your own analyte list in seconds with Restek\u2019s free <em>EZ<\/em>GC chromatogram modeler.<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><a href=\"https:\/\/explore.restek.com\/RMX-contact-technical-service\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"170\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-1024x170.png\" alt=\"helpful person on the phone\" class=\"wp-image-79797\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-1024x170.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-300x50.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-768x127.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE.png 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n<\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><a href=\"https:\/\/explore.restek.com\/RMX-contact-sales\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"170\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-1024x170.png\" alt=\"\" class=\"wp-image-79803\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-1024x170.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-300x50.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-768x127.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES.png 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n<\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Semivolatiles analysis is a cornerstone application in environmental testing laboratories around the world. Because semivolatiles vary extensively in compound chemistry and reactivity, they are often analyzed on different columns, which means valuable productivity gains can be made if methods can be consolidated onto a single column. However, successful method consolidation hinges on the effectiveness of the GC column deactivation, and traditional deactivations tend to work well for some compound classes but not for others. Restek has developed a next-generation TriMax deactivation technology that is applied to all RMX columns and has been proven to be broadly effective, outperforming even premium competitor columns [1].<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A recent study showed that RMX-5Sil MS columns produced more symmetrical peak shapes across a wider range of semivolatile classes, which resulted in more compounds meeting data requirements for linearity and recovery [2]. The current application expands on that foundational work by optimizing analytical conditions and extending the target compound list to 150 commonly analyzed semivolatiles, including internal standards and surrogates (Figure 1). As shown in Figure 2, excellent chromatographic results were obtained at trace levels (0.1-10 pg on-column) for semivolatiles across all compound classes, including reactive acidic (pentachlorophenol, 2,4-dinitrophenol) and basic (pyridine, benzidine) compounds that often have data quality requirements for system suitability. In addition, the RMX-5Sil MS column adequately separated neutral polycyclic aromatic hydrocarbons that are difficult to resolve (benzo[b] and [k]fluoroanthene).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">While this consolidated trace-level semivolatiles method demonstrates the effectiveness of an RMX-5Sil MS column across an extensive list of 150 frequently analyzed semivolatiles (cat.# 31907), labs can further adapt it to their needs using free <em>EZ<\/em>GC chromatogram modeling software to instantly create optimized methods for their own specific analyte lists and preferred column dimensions.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-image61373_bbc8c7-2d .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image61373_bbc8c7-2d\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/www.restek.com\/c\/1484\" class=\"kb-advanced-image-link\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"177\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-HTML-Block-with-Topaz-Liners-1024x177.png\" alt=\"ad for RMX columns and Topaz liners\" class=\"kb-img wp-image-89475\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-HTML-Block-with-Topaz-Liners-1024x177.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-HTML-Block-with-Topaz-Liners-300x52.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-HTML-Block-with-Topaz-Liners-768x133.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-HTML-Block-with-Topaz-Liners.png 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1: <\/strong>Expanded Trace-Level Semivolatiles Method for 150 Semivolatiles, Surrogates, and Internal Standards at 100 ppb (10 pg On-Column)<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1527.png\" alt=\"Semivolatiles on RMX-5Sil MS by GC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1527<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Mass 1<\/th><th style=\"text-align: center;width: 75px\">Product 1<\/th><th style=\"text-align: center;width: 75px\">Collision energy 1<\/th><th style=\"text-align: center;width: 75px\">Mass 2<\/th><th style=\"text-align: center;width: 75px\">Product 2<\/th><th style=\"text-align: center;width: 75px\">Collision energy 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Dioxane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/123-91-1\/1,4-Dioxane\" target=\"_blank\" rel=\"noopener\">1,4-Dioxane<\/a><\/td><td class=\"oth\">2.71<\/td><td class=\"oth\">10<\/td><td class=\"oth\">58<\/td><td class=\"oth\">28<\/td><td class=\"oth\">6<\/td><td class=\"oth\">88<\/td><td class=\"oth\">28<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosodimethylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62-75-9\/N-Nitrosodimethylamine\" target=\"_blank\" rel=\"noopener\">N-Nitrosodimethylamine<\/a><\/td><td class=\"oth\">3.02<\/td><td class=\"oth\">10<\/td><td class=\"oth\">74<\/td><td class=\"oth\">44<\/td><td class=\"oth\">6<\/td><td class=\"oth\">74<\/td><td class=\"oth\">42<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyridine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110-86-1\/Pyridine\" target=\"_blank\" rel=\"noopener\">Pyridine<\/a><\/td><td class=\"oth\">3.08<\/td><td class=\"oth\">10<\/td><td class=\"oth\">79<\/td><td class=\"oth\">52<\/td><td class=\"oth\">12<\/td><td class=\"oth\">52<\/td><td class=\"oth\">26<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethyl methacrylate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/97-63-2\/Ethyl methacrylate\" target=\"_blank\" rel=\"noopener\">Ethyl methacrylate<\/a><\/td><td class=\"oth\">3.51<\/td><td class=\"oth\">10<\/td><td class=\"oth\">69<\/td><td class=\"oth\">41<\/td><td class=\"oth\">6<\/td><td class=\"oth\">99<\/td><td class=\"oth\">43<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Picoline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/109-06-8\/2-Picoline\" target=\"_blank\" rel=\"noopener\">2-Picoline<\/a><\/td><td class=\"oth\">3.91<\/td><td class=\"oth\">10<\/td><td class=\"oth\">93<\/td><td class=\"oth\">66<\/td><td class=\"oth\">12<\/td><td class=\"oth\">93<\/td><td class=\"oth\">65<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosomethylethylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/10595-95-6\/N-Nitrosomethylethylamine\" target=\"_blank\" rel=\"noopener\">N-Nitrosomethylethylamine<\/a><\/td><td class=\"oth\">4<\/td><td class=\"oth\">10<\/td><td class=\"oth\">88<\/td><td class=\"oth\">71<\/td><td class=\"oth\">6<\/td><td class=\"oth\">88<\/td><td class=\"oth\">42<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl methanesulfonate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/66-27-3\/Methyl methanesulfonate\" target=\"_blank\" rel=\"noopener\">Methyl methanesulfonate<\/a><\/td><td class=\"oth\">4.39<\/td><td class=\"oth\">10<\/td><td class=\"oth\">80<\/td><td class=\"oth\">65<\/td><td class=\"oth\">8<\/td><td class=\"oth\">80<\/td><td class=\"oth\">48<\/td><td class=\"oth\">28<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\">Acrylamine<\/td><td class=\"oth\">4.44<\/td><td class=\"oth\">10<\/td><td class=\"oth\">71<\/td><td class=\"oth\">55<\/td><td class=\"oth\">6<\/td><td class=\"oth\">71<\/td><td class=\"oth\">44<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Fluorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/367-12-4\/2-Fluorophenol\" target=\"_blank\" rel=\"noopener\">2-Fluorophenol<\/a><\/td><td class=\"oth\">4.62<\/td><td class=\"oth\">10<\/td><td class=\"oth\">112<\/td><td class=\"oth\">92<\/td><td class=\"oth\">6<\/td><td class=\"oth\">92<\/td><td class=\"oth\">63<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosodiethylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/55-18-5\/N-Nitrosodiethylamine\" target=\"_blank\" rel=\"noopener\">N-Nitrosodiethylamine<\/a><\/td><td class=\"oth\">4.94<\/td><td class=\"oth\">10<\/td><td class=\"oth\">102<\/td><td class=\"oth\">85<\/td><td class=\"oth\">6<\/td><td class=\"oth\">102<\/td><td class=\"oth\">44<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethyl methanesulfonate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62-50-0\/Ethyl methanesulfonate\" target=\"_blank\" rel=\"noopener\">Ethyl methanesulfonate<\/a><\/td><td class=\"oth\">5.38<\/td><td class=\"oth\">10<\/td><td class=\"oth\">109<\/td><td class=\"oth\">45<\/td><td class=\"oth\">10<\/td><td class=\"oth\">109<\/td><td class=\"oth\">79<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzaldehyde\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-52-7\/Benzaldehyde\" target=\"_blank\" rel=\"noopener\">Benzaldehyde<\/a><\/td><td class=\"oth\">5.88<\/td><td class=\"oth\">10<\/td><td class=\"oth\">105<\/td><td class=\"oth\">77<\/td><td class=\"oth\">10<\/td><td class=\"oth\">105<\/td><td class=\"oth\">51<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenol-d6\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13127-88-3\/Phenol-d6\" target=\"_blank\" rel=\"noopener\">Phenol-d6<\/a><\/td><td class=\"oth\">6.02<\/td><td class=\"oth\">10<\/td><td class=\"oth\">99<\/td><td class=\"oth\">71<\/td><td class=\"oth\">8<\/td><td class=\"oth\">71<\/td><td class=\"oth\">42<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-95-2\/Phenol\" target=\"_blank\" rel=\"noopener\">Phenol<\/a><\/td><td class=\"oth\">6.04<\/td><td class=\"oth\">10<\/td><td class=\"oth\">94<\/td><td class=\"oth\">66<\/td><td class=\"oth\">10<\/td><td class=\"oth\">94<\/td><td class=\"oth\">39<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62-53-3\/Aniline\" target=\"_blank\" rel=\"noopener\">Aniline<\/a><\/td><td class=\"oth\">6.07<\/td><td class=\"oth\">10<\/td><td class=\"oth\">93<\/td><td class=\"oth\">66<\/td><td class=\"oth\">10<\/td><td class=\"oth\">93<\/td><td class=\"oth\">65<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachloroethane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-01-7\/Pentachloroethane\" target=\"_blank\" rel=\"noopener\">Pentachloroethane<\/a><\/td><td class=\"oth\">6.14<\/td><td class=\"oth\">10<\/td><td class=\"oth\">167<\/td><td class=\"oth\">132<\/td><td class=\"oth\">14<\/td><td class=\"oth\">167<\/td><td class=\"oth\">95<\/td><td class=\"oth\">32<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for bis-(2-Chloroethyl)ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111-44-4\/bis-(2-Chloroethyl)ether\" target=\"_blank\" rel=\"noopener\">bis-(2-Chloroethyl)ether<\/a><\/td><td class=\"oth\">6.18<\/td><td class=\"oth\">10<\/td><td class=\"oth\">93<\/td><td class=\"oth\">63<\/td><td class=\"oth\">6<\/td><td class=\"oth\">63<\/td><td class=\"oth\">27<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Chlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-57-8\/2-Chlorophenol\" target=\"_blank\" rel=\"noopener\">2-Chlorophenol<\/a><\/td><td class=\"oth\">6.25<\/td><td class=\"oth\">10<\/td><td class=\"oth\">128<\/td><td class=\"oth\">64<\/td><td class=\"oth\">14<\/td><td class=\"oth\">128<\/td><td class=\"oth\">63<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Decane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/124-18-5\/Decane\" target=\"_blank\" rel=\"noopener\">Decane<\/a><\/td><td class=\"oth\">6.4<\/td><td class=\"oth\">10<\/td><td class=\"oth\">85<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><td class=\"oth\">71<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,3-Dichlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/541-73-1\/1,3-Dichlorobenzene\" target=\"_blank\" rel=\"noopener\">1,3-Dichlorobenzene<\/a><\/td><td class=\"oth\">6.51<\/td><td class=\"oth\">10<\/td><td class=\"oth\">146<\/td><td class=\"oth\">111<\/td><td class=\"oth\">14<\/td><td class=\"oth\">146<\/td><td class=\"oth\">75<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Dichlorobenzene-d4\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3855-82-1\/1,4-Dichlorobenzene-d4\" target=\"_blank\" rel=\"noopener\">1,4-Dichlorobenzene-d4<\/a><\/td><td class=\"oth\">6.61<\/td><td class=\"oth\">10<\/td><td class=\"oth\">150<\/td><td class=\"oth\">115<\/td><td class=\"oth\">14<\/td><td class=\"oth\">150<\/td><td class=\"oth\">76<\/td><td class=\"oth\">38<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Dichlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-46-7\/1,4-Dichlorobenzene\" target=\"_blank\" rel=\"noopener\">1,4-Dichlorobenzene<\/a><\/td><td class=\"oth\">6.63<\/td><td class=\"oth\">10<\/td><td class=\"oth\">146<\/td><td class=\"oth\">111<\/td><td class=\"oth\">14<\/td><td class=\"oth\">146<\/td><td class=\"oth\">75<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzyl alcohol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-51-6\/Benzyl alcohol\" target=\"_blank\" rel=\"noopener\">Benzyl alcohol<\/a><\/td><td class=\"oth\">6.85<\/td><td class=\"oth\">10<\/td><td class=\"oth\">108<\/td><td class=\"oth\">79<\/td><td class=\"oth\">12<\/td><td class=\"oth\">108<\/td><td class=\"oth\">77<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,2-Dichlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-50-1\/1,2-Dichlorobenzene\" target=\"_blank\" rel=\"noopener\">1,2-Dichlorobenzene<\/a><\/td><td class=\"oth\">6.89<\/td><td class=\"oth\">10<\/td><td class=\"oth\">146<\/td><td class=\"oth\">111<\/td><td class=\"oth\">12<\/td><td class=\"oth\">111<\/td><td class=\"oth\">50<\/td><td class=\"oth\">36<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Indene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-13-6\/Indene\" target=\"_blank\" rel=\"noopener\">Indene<\/a><\/td><td class=\"oth\">7.05<\/td><td class=\"oth\">10<\/td><td class=\"oth\">115<\/td><td class=\"oth\">89<\/td><td class=\"oth\">16<\/td><td class=\"oth\">116<\/td><td class=\"oth\">89<\/td><td class=\"oth\">28<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Methylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-48-7\/2-Methylphenol\" target=\"_blank\" rel=\"noopener\">2-Methylphenol<\/a><\/td><td class=\"oth\">7.06<\/td><td class=\"oth\">10<\/td><td class=\"oth\">108<\/td><td class=\"oth\">80<\/td><td class=\"oth\">8<\/td><td class=\"oth\">108<\/td><td class=\"oth\">77<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,2&amp;apos;-oxybis(1-chloropropane)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-60-1\/2,2&amp;apos;-oxybis(1-chloropropane)\" target=\"_blank\" rel=\"noopener\">2,2&#8242;-oxybis(1-chloropropane)<\/a><\/td><td class=\"oth\">7.11<\/td><td class=\"oth\">10<\/td><td class=\"oth\">121<\/td><td class=\"oth\">45<\/td><td class=\"oth\">6<\/td><td class=\"oth\">77<\/td><td class=\"oth\">51<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosopyrrolidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/930-55-2\/N-Nitrosopyrrolidine\" target=\"_blank\" rel=\"noopener\">N-Nitrosopyrrolidine<\/a><\/td><td class=\"oth\">7.28<\/td><td class=\"oth\">10<\/td><td class=\"oth\">100<\/td><td class=\"oth\">43<\/td><td class=\"oth\">8<\/td><td class=\"oth\">100<\/td><td class=\"oth\">55<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">29.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetophenone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/98-86-2\/Acetophenone\" target=\"_blank\" rel=\"noopener\">Acetophenone<\/a><\/td><td class=\"oth\">7.31<\/td><td class=\"oth\">10<\/td><td class=\"oth\">105<\/td><td class=\"oth\">77<\/td><td class=\"oth\">12<\/td><td class=\"oth\">105<\/td><td class=\"oth\">51<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">30.<\/td><td class=\"cmpd\">3- and 4-Methylphenol<\/td><td class=\"oth\">7.33<\/td><td class=\"oth\">10<\/td><td class=\"oth\">70<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><td class=\"oth\">107<\/td><td class=\"oth\">77<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">31.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosomorpholine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59-89-2\/N-Nitrosomorpholine\" target=\"_blank\" rel=\"noopener\">N-Nitrosomorpholine<\/a><\/td><td class=\"oth\">7.331<\/td><td class=\"oth\">10<\/td><td class=\"oth\">116<\/td><td class=\"oth\">86<\/td><td class=\"oth\">6<\/td><td class=\"oth\">116<\/td><td class=\"oth\">56<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">32.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for o-Toluidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-53-4\/o-Toluidine\" target=\"_blank\" rel=\"noopener\">o-Toluidine<\/a><\/td><td class=\"oth\">7.37<\/td><td class=\"oth\">10<\/td><td class=\"oth\">106<\/td><td class=\"oth\">79<\/td><td class=\"oth\">8<\/td><td class=\"oth\">107<\/td><td class=\"oth\">77<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">33.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachloroethane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/67-72-1\/Hexachloroethane\" target=\"_blank\" rel=\"noopener\">Hexachloroethane<\/a><\/td><td class=\"oth\">7.49<\/td><td class=\"oth\">10<\/td><td class=\"oth\">201<\/td><td class=\"oth\">166<\/td><td class=\"oth\">12<\/td><td class=\"oth\">201<\/td><td class=\"oth\">131<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">34.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nitrobenzene-d5\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/4165-60-0\/Nitrobenzene-d5\" target=\"_blank\" rel=\"noopener\">Nitrobenzene-d5<\/a><\/td><td class=\"oth\">7.57<\/td><td class=\"oth\">10<\/td><td class=\"oth\">128<\/td><td class=\"oth\">82<\/td><td class=\"oth\">12<\/td><td class=\"oth\">82<\/td><td class=\"oth\">54<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">35.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/98-95-3\/Nitrobenzene\" target=\"_blank\" rel=\"noopener\">Nitrobenzene<\/a><\/td><td class=\"oth\">7.62<\/td><td class=\"oth\">10<\/td><td class=\"oth\">123<\/td><td class=\"oth\">77<\/td><td class=\"oth\">10<\/td><td class=\"oth\">123<\/td><td class=\"oth\">51<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">36.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosopiperidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-75-4\/N-Nitrosopiperidine\" target=\"_blank\" rel=\"noopener\">N-Nitrosopiperidine<\/a><\/td><td class=\"oth\">7.88<\/td><td class=\"oth\">10<\/td><td class=\"oth\">114<\/td><td class=\"oth\">84<\/td><td class=\"oth\">6<\/td><td class=\"oth\">114<\/td><td class=\"oth\">97<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">37.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isophorone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78-59-1\/Isophorone\" target=\"_blank\" rel=\"noopener\">Isophorone<\/a><\/td><td class=\"oth\">8.05<\/td><td class=\"oth\">10<\/td><td class=\"oth\">138<\/td><td class=\"oth\">82<\/td><td class=\"oth\">8<\/td><td class=\"oth\">82<\/td><td class=\"oth\">54<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">38.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Nitrophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88-75-5\/2-Nitrophenol\" target=\"_blank\" rel=\"noopener\">2-Nitrophenol<\/a><\/td><td class=\"oth\">8.19<\/td><td class=\"oth\">10<\/td><td class=\"oth\">139<\/td><td class=\"oth\">109<\/td><td class=\"oth\">8<\/td><td class=\"oth\">139<\/td><td class=\"oth\">81<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">39.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzoic acid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/65-85-0\/Benzoic acid\" target=\"_blank\" rel=\"noopener\">Benzoic acid<\/a><\/td><td class=\"oth\">8.31<\/td><td class=\"oth\">10<\/td><td class=\"oth\">122<\/td><td class=\"oth\">77<\/td><td class=\"oth\">20<\/td><td class=\"oth\">105<\/td><td class=\"oth\">77<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">40.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dimethylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/105-67-9\/2,4-Dimethylphenol\" target=\"_blank\" rel=\"noopener\">2,4-Dimethylphenol<\/a><\/td><td class=\"oth\">8.32<\/td><td class=\"oth\">10<\/td><td class=\"oth\">122<\/td><td class=\"oth\">107<\/td><td class=\"oth\">12<\/td><td class=\"oth\">122<\/td><td class=\"oth\">77<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">41.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for O,O,O-Triethyl phosphorothioate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/126-68-1\/O,O,O-Triethyl phosphorothioate\" target=\"_blank\" rel=\"noopener\">O,O,O-Triethyl phosphorothioate<\/a><\/td><td class=\"oth\">8.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">121<\/td><td class=\"oth\">65<\/td><td class=\"oth\">10<\/td><td class=\"oth\">198<\/td><td class=\"oth\">114<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">42.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bis(2-chloroethoxy)methane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111-91-1\/Bis(2-chloroethoxy)methane\" target=\"_blank\" rel=\"noopener\">Bis(2-chloroethoxy)methane<\/a><\/td><td class=\"oth\">8.5<\/td><td class=\"oth\">10<\/td><td class=\"oth\">63<\/td><td class=\"oth\">27<\/td><td class=\"oth\">12<\/td><td class=\"oth\">93<\/td><td class=\"oth\">63<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">43.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dichlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-83-2\/2,4-Dichlorophenol\" target=\"_blank\" rel=\"noopener\">2,4-Dichlorophenol<\/a><\/td><td class=\"oth\">8.64<\/td><td class=\"oth\">10<\/td><td class=\"oth\">98<\/td><td class=\"oth\">63<\/td><td class=\"oth\">8<\/td><td class=\"oth\">162<\/td><td class=\"oth\">98<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">44.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phentermine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/122-09-8\/Phentermine\" target=\"_blank\" rel=\"noopener\">Phentermine<\/a><\/td><td class=\"oth\">8.78<\/td><td class=\"oth\">10<\/td><td class=\"oth\">58<\/td><td class=\"oth\">42<\/td><td class=\"oth\">22<\/td><td class=\"oth\">134<\/td><td class=\"oth\">91<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">45.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,2,4-Trichlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-82-1\/1,2,4-Trichlorobenzene\" target=\"_blank\" rel=\"noopener\">1,2,4-Trichlorobenzene<\/a><\/td><td class=\"oth\">8.8<\/td><td class=\"oth\">10<\/td><td class=\"oth\">180<\/td><td class=\"oth\">145<\/td><td class=\"oth\">12<\/td><td class=\"oth\">180<\/td><td class=\"oth\">109<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">46.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Naphthalene-d8\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1146-65-2\/Naphthalene-d8\" target=\"_blank\" rel=\"noopener\">Naphthalene-d8<\/a><\/td><td class=\"oth\">8.89<\/td><td class=\"oth\">10<\/td><td class=\"oth\">136<\/td><td class=\"oth\">134<\/td><td class=\"oth\">14<\/td><td class=\"oth\">136<\/td><td class=\"oth\">84<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">47.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Naphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-20-3\/Naphthalene\" target=\"_blank\" rel=\"noopener\">Naphthalene<\/a><\/td><td class=\"oth\">8.92<\/td><td class=\"oth\">10<\/td><td class=\"oth\">128<\/td><td class=\"oth\">102<\/td><td class=\"oth\">16<\/td><td class=\"oth\">129<\/td><td class=\"oth\">103<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">48.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-Terpineol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/98-55-5\/\u03b1-Terpineol\" target=\"_blank\" rel=\"noopener\">\u03b1-Terpineol<\/a><\/td><td class=\"oth\">9<\/td><td class=\"oth\">10<\/td><td class=\"oth\">136<\/td><td class=\"oth\">121<\/td><td class=\"oth\">8<\/td><td class=\"oth\">136<\/td><td class=\"oth\">93<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">49.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Chloroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-47-8\/4-Chloroaniline\" target=\"_blank\" rel=\"noopener\">4-Chloroaniline<\/a><\/td><td class=\"oth\">9.06<\/td><td class=\"oth\">10<\/td><td class=\"oth\">127<\/td><td class=\"oth\">100<\/td><td class=\"oth\">10<\/td><td class=\"oth\">127<\/td><td class=\"oth\">65<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">50.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,6-Dichlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/87-65-0\/2,6-Dichlorophenol\" target=\"_blank\" rel=\"noopener\">2,6-Dichlorophenol<\/a><\/td><td class=\"oth\">9.07<\/td><td class=\"oth\">10<\/td><td class=\"oth\">162<\/td><td class=\"oth\">126<\/td><td class=\"oth\">8<\/td><td class=\"oth\">164<\/td><td class=\"oth\">63<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">51.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachloropropene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1888-71-7\/Hexachloropropene\" target=\"_blank\" rel=\"noopener\">Hexachloropropene<\/a><\/td><td class=\"oth\">9.12<\/td><td class=\"oth\">10<\/td><td class=\"oth\">213<\/td><td class=\"oth\">119<\/td><td class=\"oth\">18<\/td><td class=\"oth\">215<\/td><td class=\"oth\">119<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">52.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachlorobutadiene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/87-68-3\/Hexachlorobutadiene\" target=\"_blank\" rel=\"noopener\">Hexachlorobutadiene<\/a><\/td><td class=\"oth\">9.21<\/td><td class=\"oth\">10<\/td><td class=\"oth\">225<\/td><td class=\"oth\">190<\/td><td class=\"oth\">14<\/td><td class=\"oth\">260<\/td><td class=\"oth\">190<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">53.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Quinoline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-22-5\/Quinoline\" target=\"_blank\" rel=\"noopener\">Quinoline<\/a><\/td><td class=\"oth\">9.56<\/td><td class=\"oth\">10<\/td><td class=\"oth\">129<\/td><td class=\"oth\">102<\/td><td class=\"oth\">16<\/td><td class=\"oth\">129<\/td><td class=\"oth\">76<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">54.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Caprolactam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/105-60-2\/Caprolactam\" target=\"_blank\" rel=\"noopener\">Caprolactam<\/a><\/td><td class=\"oth\">9.65<\/td><td class=\"oth\">10<\/td><td class=\"oth\">113<\/td><td class=\"oth\">85<\/td><td class=\"oth\">6<\/td><td class=\"oth\">113<\/td><td class=\"oth\">56<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">55.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Phenylenediamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-50-3\/1,4-Phenylenediamine\" target=\"_blank\" rel=\"noopener\">1,4-Phenylenediamine<\/a><\/td><td class=\"oth\">9.73<\/td><td class=\"oth\">10<\/td><td class=\"oth\">108<\/td><td class=\"oth\">81<\/td><td class=\"oth\">10<\/td><td class=\"oth\">108<\/td><td class=\"oth\">80<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">56.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosodibutylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/924-16-3\/N-Nitrosodibutylamine\" target=\"_blank\" rel=\"noopener\">N-Nitrosodibutylamine<\/a><\/td><td class=\"oth\">9.76<\/td><td class=\"oth\">10<\/td><td class=\"oth\">116<\/td><td class=\"oth\">99<\/td><td class=\"oth\">6<\/td><td class=\"oth\">116<\/td><td class=\"oth\">74<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">57.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Chloro-3-methylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59-50-7\/4-Chloro-3-methylphenol\" target=\"_blank\" rel=\"noopener\">4-Chloro-3-methylphenol<\/a><\/td><td class=\"oth\">10.05<\/td><td class=\"oth\">10<\/td><td class=\"oth\">142<\/td><td class=\"oth\">107<\/td><td class=\"oth\">12<\/td><td class=\"oth\">142<\/td><td class=\"oth\">77<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">58.<\/td><td class=\"cmpd\">Isosafrole I<\/td><td class=\"oth\">10.14<\/td><td class=\"oth\">10<\/td><td class=\"oth\">131<\/td><td class=\"oth\">103<\/td><td class=\"oth\">8<\/td><td class=\"oth\">162<\/td><td class=\"oth\">104<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">59.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Methylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-57-6\/2-Methylnaphthalene\" target=\"_blank\" rel=\"noopener\">2-Methylnaphthalene<\/a><\/td><td class=\"oth\">10.27<\/td><td class=\"oth\">10<\/td><td class=\"oth\">141<\/td><td class=\"oth\">115<\/td><td class=\"oth\">16<\/td><td class=\"oth\">141<\/td><td class=\"oth\">89<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">60.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Methylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90-12-0\/1-Methylnaphthalene\" target=\"_blank\" rel=\"noopener\">1-Methylnaphthalene<\/a><\/td><td class=\"oth\">10.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">141<\/td><td class=\"oth\">115<\/td><td class=\"oth\">16<\/td><td class=\"oth\">141<\/td><td class=\"oth\">89<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">61.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,2,4,5-Tetrachlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-94-3\/1,2,4,5-Tetrachlorobenzene\" target=\"_blank\" rel=\"noopener\">1,2,4,5-Tetrachlorobenzene<\/a><\/td><td class=\"oth\">10.61<\/td><td class=\"oth\">10<\/td><td class=\"oth\">216<\/td><td class=\"oth\">181<\/td><td class=\"oth\">14<\/td><td class=\"oth\">216<\/td><td class=\"oth\">108<\/td><td class=\"oth\">36<\/td><\/tr>\n<tr><td class=\"num\">62.<\/td><td class=\"cmpd\">Hexachloropentadiene<\/td><td class=\"oth\">10.62<\/td><td class=\"oth\">10<\/td><td class=\"oth\">272<\/td><td class=\"oth\">237<\/td><td class=\"oth\">12<\/td><td class=\"oth\">237<\/td><td class=\"oth\">143<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">63.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,3-Dichloroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/608-27-5\/2,3-Dichloroaniline\" target=\"_blank\" rel=\"noopener\">2,3-Dichloroaniline<\/a><\/td><td class=\"oth\">10.83<\/td><td class=\"oth\">10<\/td><td class=\"oth\">161<\/td><td class=\"oth\">90<\/td><td class=\"oth\">16<\/td><td class=\"oth\">163<\/td><td class=\"oth\">90<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">64.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4,6-Trichlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88-06-2\/2,4,6-Trichlorophenol\" target=\"_blank\" rel=\"noopener\">2,4,6-Trichlorophenol<\/a><\/td><td class=\"oth\">10.85<\/td><td class=\"oth\">10<\/td><td class=\"oth\">132<\/td><td class=\"oth\">97<\/td><td class=\"oth\">10<\/td><td class=\"oth\">196<\/td><td class=\"oth\">97<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">65.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4,5-Trichlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-95-4\/2,4,5-Trichlorophenol\" target=\"_blank\" rel=\"noopener\">2,4,5-Trichlorophenol<\/a><\/td><td class=\"oth\">10.95<\/td><td class=\"oth\">10<\/td><td class=\"oth\">132<\/td><td class=\"oth\">97<\/td><td class=\"oth\">10<\/td><td class=\"oth\">196<\/td><td class=\"oth\">97<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">66.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Fluorobiphenyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/321-60-8\/2-Fluorobiphenyl\" target=\"_blank\" rel=\"noopener\">2-Fluorobiphenyl<\/a><\/td><td class=\"oth\">11.03<\/td><td class=\"oth\">10<\/td><td class=\"oth\">172<\/td><td class=\"oth\">171<\/td><td class=\"oth\">12<\/td><td class=\"oth\">172<\/td><td class=\"oth\">170<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">67.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Chloronaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-58-7\/2-Chloronaphthalene\" target=\"_blank\" rel=\"noopener\">2-Chloronaphthalene<\/a><\/td><td class=\"oth\">11.15<\/td><td class=\"oth\">10<\/td><td class=\"oth\">162<\/td><td class=\"oth\">127<\/td><td class=\"oth\">16<\/td><td class=\"oth\">162<\/td><td class=\"oth\">77<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">68.<\/td><td class=\"cmpd\">Isosafrole II<\/td><td class=\"oth\">11.17<\/td><td class=\"oth\">10<\/td><td class=\"oth\">131<\/td><td class=\"oth\">103<\/td><td class=\"oth\">10<\/td><td class=\"oth\">162<\/td><td class=\"oth\">104<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">69.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Safrole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/94-59-7\/Safrole\" target=\"_blank\" rel=\"noopener\">Safrole<\/a><\/td><td class=\"oth\">11.2<\/td><td class=\"oth\">10<\/td><td class=\"oth\">162<\/td><td class=\"oth\">127<\/td><td class=\"oth\">16<\/td><td class=\"oth\">131<\/td><td class=\"oth\">103<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">70.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Biphenyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92-52-4\/Biphenyl\" target=\"_blank\" rel=\"noopener\">Biphenyl<\/a><\/td><td class=\"oth\">11.21<\/td><td class=\"oth\">10<\/td><td class=\"oth\">154<\/td><td class=\"oth\">152<\/td><td class=\"oth\">22<\/td><td class=\"oth\">153<\/td><td class=\"oth\">126<\/td><td class=\"oth\">32<\/td><\/tr>\n<tr><td class=\"num\">71.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Chloronaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90-13-1\/1-Chloronaphthalene\" target=\"_blank\" rel=\"noopener\">1-Chloronaphthalene<\/a><\/td><td class=\"oth\">11.25<\/td><td class=\"oth\">10<\/td><td class=\"oth\">162<\/td><td class=\"oth\">127<\/td><td class=\"oth\">16<\/td><td class=\"oth\">127<\/td><td class=\"oth\">77<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">72.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for o-Nitroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88-74-4\/o-Nitroaniline\" target=\"_blank\" rel=\"noopener\">o-Nitroaniline<\/a><\/td><td class=\"oth\">11.43<\/td><td class=\"oth\">10<\/td><td class=\"oth\">138<\/td><td class=\"oth\">92<\/td><td class=\"oth\">12<\/td><td class=\"oth\">138<\/td><td class=\"oth\">65<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">73.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diphenyl ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/101-84-8\/Diphenyl ether\" target=\"_blank\" rel=\"noopener\">Diphenyl ether<\/a><\/td><td class=\"oth\">11.43<\/td><td class=\"oth\">10<\/td><td class=\"oth\">170<\/td><td class=\"oth\">142<\/td><td class=\"oth\">10<\/td><td class=\"oth\">141<\/td><td class=\"oth\">115<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">74.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Naphthoquinone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/130-15-4\/1,4-Naphthoquinone\" target=\"_blank\" rel=\"noopener\">1,4-Naphthoquinone<\/a><\/td><td class=\"oth\">11.57<\/td><td class=\"oth\">10<\/td><td class=\"oth\">158<\/td><td class=\"oth\">130<\/td><td class=\"oth\">8<\/td><td class=\"oth\">158<\/td><td class=\"oth\">102<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">75.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,2-Dinitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/528-29-0\/1,2-Dinitrobenzene\" target=\"_blank\" rel=\"noopener\">1,2-Dinitrobenzene<\/a><\/td><td class=\"oth\">11.86<\/td><td class=\"oth\">10<\/td><td class=\"oth\">122<\/td><td class=\"oth\">75<\/td><td class=\"oth\">12<\/td><td class=\"oth\">168<\/td><td class=\"oth\">75<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">76.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,3-Dinitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-65-0\/1,3-Dinitrobenzene\" target=\"_blank\" rel=\"noopener\">1,3-Dinitrobenzene<\/a><\/td><td class=\"oth\">11.87<\/td><td class=\"oth\">10<\/td><td class=\"oth\">168<\/td><td class=\"oth\">75<\/td><td class=\"oth\">20<\/td><td class=\"oth\">76<\/td><td class=\"oth\">50<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">77.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diphenyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/84-62-8\/Diphenyl phthalate\" target=\"_blank\" rel=\"noopener\">Diphenyl phthalate<\/a><\/td><td class=\"oth\">11.87<\/td><td class=\"oth\">10<\/td><td class=\"oth\">163<\/td><td class=\"oth\">133<\/td><td class=\"oth\">8<\/td><td class=\"oth\">163<\/td><td class=\"oth\">77<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">78.<\/td><td class=\"cmpd\">1,6-Dinitrotoluene<\/td><td class=\"oth\">11.95<\/td><td class=\"oth\">10<\/td><td class=\"oth\">165<\/td><td class=\"oth\">148<\/td><td class=\"oth\">8<\/td><td class=\"oth\">165<\/td><td class=\"oth\">63<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">79.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Dinitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-25-4\/1,4-Dinitrobenzene\" target=\"_blank\" rel=\"noopener\">1,4-Dinitrobenzene<\/a><\/td><td class=\"oth\">12.01<\/td><td class=\"oth\">10<\/td><td class=\"oth\">168<\/td><td class=\"oth\">51<\/td><td class=\"oth\">14<\/td><td class=\"oth\">76<\/td><td class=\"oth\">63<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">80.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/208-96-8\/Acenaphthylene\" target=\"_blank\" rel=\"noopener\">Acenaphthylene<\/a><\/td><td class=\"oth\">12.02<\/td><td class=\"oth\">10<\/td><td class=\"oth\">152<\/td><td class=\"oth\">126<\/td><td class=\"oth\">24<\/td><td class=\"oth\">152<\/td><td class=\"oth\">76<\/td><td class=\"oth\">36<\/td><\/tr>\n<tr><td class=\"num\">81.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3-Nitroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-09-2\/3-Nitroaniline\" target=\"_blank\" rel=\"noopener\">3-Nitroaniline<\/a><\/td><td class=\"oth\">12.25<\/td><td class=\"oth\">10<\/td><td class=\"oth\">92<\/td><td class=\"oth\">65<\/td><td class=\"oth\">8<\/td><td class=\"oth\">138<\/td><td class=\"oth\">65<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">82.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthene-d10\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/15067-26-2\/Acenaphthene-d10\" target=\"_blank\" rel=\"noopener\">Acenaphthene-d10<\/a><\/td><td class=\"oth\">12.32<\/td><td class=\"oth\">10<\/td><td class=\"oth\">164<\/td><td class=\"oth\">162<\/td><td class=\"oth\">14<\/td><td class=\"oth\">164<\/td><td class=\"oth\">160<\/td><td class=\"oth\">32<\/td><\/tr>\n<tr><td class=\"num\">83.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/83-32-9\/Acenaphthene\" target=\"_blank\" rel=\"noopener\">Acenaphthene<\/a><\/td><td class=\"oth\">12.37<\/td><td class=\"oth\">10<\/td><td class=\"oth\">153<\/td><td class=\"oth\">126<\/td><td class=\"oth\">36<\/td><td class=\"oth\">153<\/td><td class=\"oth\">77<\/td><td class=\"oth\">38<\/td><\/tr>\n<tr><td class=\"num\">84.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dinitrophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51-28-5\/2,4-Dinitrophenol\" target=\"_blank\" rel=\"noopener\">2,4-Dinitrophenol<\/a><\/td><td class=\"oth\">12.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">184<\/td><td class=\"oth\">154<\/td><td class=\"oth\">6<\/td><td class=\"oth\">184<\/td><td class=\"oth\">107<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">85.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Nitrophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-02-7\/4-Nitrophenol\" target=\"_blank\" rel=\"noopener\">4-Nitrophenol<\/a><\/td><td class=\"oth\">12.65<\/td><td class=\"oth\">10<\/td><td class=\"oth\">139<\/td><td class=\"oth\">109<\/td><td class=\"oth\">6<\/td><td class=\"oth\">139<\/td><td class=\"oth\">81<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">86.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/608-93-5\/Pentachlorobenzene\" target=\"_blank\" rel=\"noopener\">Pentachlorobenzene<\/a><\/td><td class=\"oth\">12.66<\/td><td class=\"oth\">10<\/td><td class=\"oth\">250<\/td><td class=\"oth\">215<\/td><td class=\"oth\">16<\/td><td class=\"oth\">250<\/td><td class=\"oth\">142<\/td><td class=\"oth\">38<\/td><\/tr>\n<tr><td class=\"num\">87.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenzofuran\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/132-64-9\/Dibenzofuran\" target=\"_blank\" rel=\"noopener\">Dibenzofuran<\/a><\/td><td class=\"oth\">12.73<\/td><td class=\"oth\">10<\/td><td class=\"oth\">168<\/td><td class=\"oth\">139<\/td><td class=\"oth\">22<\/td><td class=\"oth\">139<\/td><td class=\"oth\">63<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">88.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dinitrotoluene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/121-14-2\/2,4-Dinitrotoluene\" target=\"_blank\" rel=\"noopener\">2,4-Dinitrotoluene<\/a><\/td><td class=\"oth\">12.74<\/td><td class=\"oth\">10<\/td><td class=\"oth\">165<\/td><td class=\"oth\">119<\/td><td class=\"oth\">6<\/td><td class=\"oth\">165<\/td><td class=\"oth\">63<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">89.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Naphthylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/134-32-7\/1-Naphthylamine\" target=\"_blank\" rel=\"noopener\">1-Naphthylamine<\/a><\/td><td class=\"oth\">12.88<\/td><td class=\"oth\">10<\/td><td class=\"oth\">143<\/td><td class=\"oth\">116<\/td><td class=\"oth\">10<\/td><td class=\"oth\">143<\/td><td class=\"oth\">115<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">90.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,3,5,6-Tetrachlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/935-95-5\/2,3,5,6-Tetrachlorophenol\" target=\"_blank\" rel=\"noopener\">2,3,5,6-Tetrachlorophenol<\/a><\/td><td class=\"oth\">12.91<\/td><td class=\"oth\">10<\/td><td class=\"oth\">232<\/td><td class=\"oth\">168<\/td><td class=\"oth\">12<\/td><td class=\"oth\">234<\/td><td class=\"oth\">133<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">91.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,3,4,6-Tetrachlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/58-90-2\/2,3,4,6-Tetrachlorophenol\" target=\"_blank\" rel=\"noopener\">2,3,4,6-Tetrachlorophenol<\/a><\/td><td class=\"oth\">13<\/td><td class=\"oth\">10<\/td><td class=\"oth\">232<\/td><td class=\"oth\">168<\/td><td class=\"oth\">12<\/td><td class=\"oth\">234<\/td><td class=\"oth\">131<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">92.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Naphthylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-59-8\/2-Naphthylamine\" target=\"_blank\" rel=\"noopener\">2-Naphthylamine<\/a><\/td><td class=\"oth\">13.03<\/td><td class=\"oth\">10<\/td><td class=\"oth\">143<\/td><td class=\"oth\">116<\/td><td class=\"oth\">10<\/td><td class=\"oth\">143<\/td><td class=\"oth\">115<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">93.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diethyl Phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/84-66-2\/Diethyl Phthalate\" target=\"_blank\" rel=\"noopener\">Diethyl Phthalate<\/a><\/td><td class=\"oth\">13.3<\/td><td class=\"oth\">10<\/td><td class=\"oth\">177<\/td><td class=\"oth\">149<\/td><td class=\"oth\">8<\/td><td class=\"oth\">149<\/td><td class=\"oth\">65<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">94.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexadecane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/544-76-3\/Hexadecane\" target=\"_blank\" rel=\"noopener\">Hexadecane<\/a><\/td><td class=\"oth\">13.41<\/td><td class=\"oth\">10<\/td><td class=\"oth\">85<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><td class=\"oth\">99<\/td><td class=\"oth\">41<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">95.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluorene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/86-73-7\/Fluorene\" target=\"_blank\" rel=\"noopener\">Fluorene<\/a><\/td><td class=\"oth\">13.41<\/td><td class=\"oth\">10<\/td><td class=\"oth\">165<\/td><td class=\"oth\">139<\/td><td class=\"oth\">26<\/td><td class=\"oth\">167<\/td><td class=\"oth\">166<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">96.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Zinophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/297-97-2\/Zinophos\" target=\"_blank\" rel=\"noopener\">Zinophos<\/a><\/td><td class=\"oth\">13.45<\/td><td class=\"oth\">10<\/td><td class=\"oth\">143<\/td><td class=\"oth\">79<\/td><td class=\"oth\">10<\/td><td class=\"oth\">107<\/td><td class=\"oth\">52<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">97.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 5-Nitro-o-toluidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-55-8\/5-Nitro-o-toluidine\" target=\"_blank\" rel=\"noopener\">5-Nitro-o-toluidine<\/a><\/td><td class=\"oth\">13.45<\/td><td class=\"oth\">10<\/td><td class=\"oth\">152<\/td><td class=\"oth\">106<\/td><td class=\"oth\">10<\/td><td class=\"oth\">152<\/td><td class=\"oth\">77<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">98.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Nitroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-01-6\/4-Nitroaniline\" target=\"_blank\" rel=\"noopener\">4-Nitroaniline<\/a><\/td><td class=\"oth\">13.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">138<\/td><td class=\"oth\">108<\/td><td class=\"oth\">8<\/td><td class=\"oth\">138<\/td><td class=\"oth\">80<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">99.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Chlorophenyl phenyl ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7005-72-3\/4-Chlorophenyl phenyl ether\" target=\"_blank\" rel=\"noopener\">4-Chlorophenyl phenyl ether<\/a><\/td><td class=\"oth\">13.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">204<\/td><td class=\"oth\">77<\/td><td class=\"oth\">22<\/td><td class=\"oth\">141<\/td><td class=\"oth\">115<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">100.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4,6-Dinitro-2-methylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/534-52-1\/4,6-Dinitro-2-methylphenol\" target=\"_blank\" rel=\"noopener\">4,6-Dinitro-2-methylphenol<\/a><\/td><td class=\"oth\">13.54<\/td><td class=\"oth\">10<\/td><td class=\"oth\">198<\/td><td class=\"oth\">168<\/td><td class=\"oth\">6<\/td><td class=\"oth\">198<\/td><td class=\"oth\">121<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">101.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diphenylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/122-39-4\/Diphenylamine\" target=\"_blank\" rel=\"noopener\">Diphenylamine<\/a><\/td><td class=\"oth\">13.7<\/td><td class=\"oth\">10<\/td><td class=\"oth\">169<\/td><td class=\"oth\">66<\/td><td class=\"oth\">22<\/td><td class=\"oth\">169<\/td><td class=\"oth\">77<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">102.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Azobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/103-33-3\/Azobenzene\" target=\"_blank\" rel=\"noopener\">Azobenzene<\/a><\/td><td class=\"oth\">13.76<\/td><td class=\"oth\">10<\/td><td class=\"oth\">182<\/td><td class=\"oth\">105<\/td><td class=\"oth\">6<\/td><td class=\"oth\">182<\/td><td class=\"oth\">77<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">103.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4,6-Tribromophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/118-79-6\/2,4,6-Tribromophenol\" target=\"_blank\" rel=\"noopener\">2,4,6-Tribromophenol<\/a><\/td><td class=\"oth\">13.88<\/td><td class=\"oth\">10<\/td><td class=\"oth\">330<\/td><td class=\"oth\">222<\/td><td class=\"oth\">20<\/td><td class=\"oth\">332<\/td><td class=\"oth\">143<\/td><td class=\"oth\">34<\/td><\/tr>\n<tr><td class=\"num\">104.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Sulfotepp\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3689-24-5\/Sulfotepp\" target=\"_blank\" rel=\"noopener\">Sulfotepp<\/a><\/td><td class=\"oth\">14.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">202<\/td><td class=\"oth\">146<\/td><td class=\"oth\">10<\/td><td class=\"oth\">322<\/td><td class=\"oth\">146<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">105.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,3,5-Trinitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-35-4\/1,3,5-Trinitrobenzene\" target=\"_blank\" rel=\"noopener\">1,3,5-Trinitrobenzene<\/a><\/td><td class=\"oth\">14.23<\/td><td class=\"oth\">10<\/td><td class=\"oth\">213<\/td><td class=\"oth\">167<\/td><td class=\"oth\">8<\/td><td class=\"oth\">213<\/td><td class=\"oth\">74<\/td><td class=\"oth\">38<\/td><\/tr>\n<tr><td class=\"num\">106.<\/td><td class=\"cmpd\">Diallate 1<\/td><td class=\"oth\">14.31<\/td><td class=\"oth\">10<\/td><td class=\"oth\">86<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><td class=\"oth\">234<\/td><td class=\"oth\">150<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">107.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phorate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-02-2\/Phorate\" target=\"_blank\" rel=\"noopener\">Phorate<\/a><\/td><td class=\"oth\">14.32<\/td><td class=\"oth\">10<\/td><td class=\"oth\">75<\/td><td class=\"oth\">47<\/td><td class=\"oth\">8<\/td><td class=\"oth\">121<\/td><td class=\"oth\">47<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">108.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenacetin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62-44-2\/Phenacetin\" target=\"_blank\" rel=\"noopener\">Phenacetin<\/a><\/td><td class=\"oth\">14.35<\/td><td class=\"oth\">10<\/td><td class=\"oth\">179<\/td><td class=\"oth\">137<\/td><td class=\"oth\">8<\/td><td class=\"oth\">179<\/td><td class=\"oth\">109<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">109.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Bromophenyl phenyl ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/101-55-3\/4-Bromophenyl phenyl ether\" target=\"_blank\" rel=\"noopener\">4-Bromophenyl phenyl ether<\/a><\/td><td class=\"oth\">14.41<\/td><td class=\"oth\">10<\/td><td class=\"oth\">248<\/td><td class=\"oth\">141<\/td><td class=\"oth\">14<\/td><td class=\"oth\">141<\/td><td class=\"oth\">115<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">110.<\/td><td class=\"cmpd\">Diallate 2<\/td><td class=\"oth\">14.48<\/td><td class=\"oth\">10<\/td><td class=\"oth\">234<\/td><td class=\"oth\">150<\/td><td class=\"oth\">16<\/td><td class=\"oth\">86<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">111.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/118-74-1\/Hexachlorobenzene\" target=\"_blank\" rel=\"noopener\">Hexachlorobenzene<\/a><\/td><td class=\"oth\">14.5<\/td><td class=\"oth\">10<\/td><td class=\"oth\">284<\/td><td class=\"oth\">249<\/td><td class=\"oth\">14<\/td><td class=\"oth\">288<\/td><td class=\"oth\">216<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">112.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dimethoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60-51-5\/Dimethoate\" target=\"_blank\" rel=\"noopener\">Dimethoate<\/a><\/td><td class=\"oth\">14.6<\/td><td class=\"oth\">10<\/td><td class=\"oth\">93<\/td><td class=\"oth\">63<\/td><td class=\"oth\">8<\/td><td class=\"oth\">125<\/td><td class=\"oth\">47<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">113.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Atrazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1912-24-9\/Atrazine\" target=\"_blank\" rel=\"noopener\">Atrazine<\/a><\/td><td class=\"oth\">14.82<\/td><td class=\"oth\">10<\/td><td class=\"oth\">200<\/td><td class=\"oth\">122<\/td><td class=\"oth\">8<\/td><td class=\"oth\">215<\/td><td class=\"oth\">200<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">114.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/87-86-5\/Pentachlorophenol\" target=\"_blank\" rel=\"noopener\">Pentachlorophenol<\/a><\/td><td class=\"oth\">14.9<\/td><td class=\"oth\">10<\/td><td class=\"oth\">266<\/td><td class=\"oth\">167<\/td><td class=\"oth\">22<\/td><td class=\"oth\">270<\/td><td class=\"oth\">169<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">115.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Aminobiphenyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92-67-1\/4-Aminobiphenyl\" target=\"_blank\" rel=\"noopener\">4-Aminobiphenyl<\/a><\/td><td class=\"oth\">14.93<\/td><td class=\"oth\">10<\/td><td class=\"oth\">168<\/td><td class=\"oth\">141<\/td><td class=\"oth\">8<\/td><td class=\"oth\">168<\/td><td class=\"oth\">167<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">116.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachloronitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/82-68-8\/Pentachloronitrobenzene\" target=\"_blank\" rel=\"noopener\">Pentachloronitrobenzene<\/a><\/td><td class=\"oth\">14.93<\/td><td class=\"oth\">10<\/td><td class=\"oth\">295<\/td><td class=\"oth\">265<\/td><td class=\"oth\">8<\/td><td class=\"oth\">237<\/td><td class=\"oth\">143<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">117.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propyzamide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/23950-58-5\/Propyzamide\" target=\"_blank\" rel=\"noopener\">Propyzamide<\/a><\/td><td class=\"oth\">15.13<\/td><td class=\"oth\">10<\/td><td class=\"oth\">173<\/td><td class=\"oth\">145<\/td><td class=\"oth\">14<\/td><td class=\"oth\">254<\/td><td class=\"oth\">191<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">118.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenanthrene-d10\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1517-22-2\/Phenanthrene-d10\" target=\"_blank\" rel=\"noopener\">Phenanthrene-d10<\/a><\/td><td class=\"oth\">15.24<\/td><td class=\"oth\">10<\/td><td class=\"oth\">188<\/td><td class=\"oth\">160<\/td><td class=\"oth\">20<\/td><td class=\"oth\">184<\/td><td class=\"oth\">154<\/td><td class=\"oth\">32<\/td><\/tr>\n<tr><td class=\"num\">119.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Octadecane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/593-45-3\/Octadecane\" target=\"_blank\" rel=\"noopener\">Octadecane<\/a><\/td><td class=\"oth\">15.27<\/td><td class=\"oth\">10<\/td><td class=\"oth\">85<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><td class=\"oth\">99<\/td><td class=\"oth\">41<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">120.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenanthrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85-01-8\/Phenanthrene\" target=\"_blank\" rel=\"noopener\">Phenanthrene<\/a><\/td><td class=\"oth\">15.29<\/td><td class=\"oth\">10<\/td><td class=\"oth\">178<\/td><td class=\"oth\">152<\/td><td class=\"oth\">18<\/td><td class=\"oth\">178<\/td><td class=\"oth\">151<\/td><td class=\"oth\">32<\/td><\/tr>\n<tr><td class=\"num\">121.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dinoseb\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88-85-7\/Dinoseb\" target=\"_blank\" rel=\"noopener\">Dinoseb<\/a><\/td><td class=\"oth\">15.34<\/td><td class=\"oth\">10<\/td><td class=\"oth\">163<\/td><td class=\"oth\">116<\/td><td class=\"oth\">14<\/td><td class=\"oth\">240<\/td><td class=\"oth\">117<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">122.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Disulfoton\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-04-4\/Disulfoton\" target=\"_blank\" rel=\"noopener\">Disulfoton<\/a><\/td><td class=\"oth\">15.36<\/td><td class=\"oth\">10<\/td><td class=\"oth\">88<\/td><td class=\"oth\">60<\/td><td class=\"oth\">6<\/td><td class=\"oth\">97<\/td><td class=\"oth\">65<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">123.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-12-7\/Anthracene\" target=\"_blank\" rel=\"noopener\">Anthracene<\/a><\/td><td class=\"oth\">15.39<\/td><td class=\"oth\">10<\/td><td class=\"oth\">178<\/td><td class=\"oth\">152<\/td><td class=\"oth\">18<\/td><td class=\"oth\">178<\/td><td class=\"oth\">151<\/td><td class=\"oth\">32<\/td><\/tr>\n<tr><td class=\"num\">124.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carbazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/86-74-8\/Carbazole\" target=\"_blank\" rel=\"noopener\">Carbazole<\/a><\/td><td class=\"oth\">15.741<\/td><td class=\"oth\">10<\/td><td class=\"oth\">167<\/td><td class=\"oth\">166<\/td><td class=\"oth\">12<\/td><td class=\"oth\">167<\/td><td class=\"oth\">139<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">125.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl Parathion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-00-0\/Methyl Parathion\" target=\"_blank\" rel=\"noopener\">Methyl Parathion<\/a><\/td><td class=\"oth\">16.08<\/td><td class=\"oth\">10<\/td><td class=\"oth\">263<\/td><td class=\"oth\">109<\/td><td class=\"oth\">10<\/td><td class=\"oth\">263<\/td><td class=\"oth\">79<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">126.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for di-n-Butyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/84-74-2\/di-n-Butyl phthalate\" target=\"_blank\" rel=\"noopener\">di-n-Butyl phthalate<\/a><\/td><td class=\"oth\">16.58<\/td><td class=\"oth\">10<\/td><td class=\"oth\">149<\/td><td class=\"oth\">121<\/td><td class=\"oth\">12<\/td><td class=\"oth\">149<\/td><td class=\"oth\">65<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">127.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Nitroquinoline-N-oxide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-57-5\/4-Nitroquinoline-N-oxide\" target=\"_blank\" rel=\"noopener\">4-Nitroquinoline-N-oxide<\/a><\/td><td class=\"oth\">16.83<\/td><td class=\"oth\">10<\/td><td class=\"oth\">190<\/td><td class=\"oth\">160<\/td><td class=\"oth\">8<\/td><td class=\"oth\">101<\/td><td class=\"oth\">75<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">128.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethyl Parathion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-38-2\/Ethyl Parathion\" target=\"_blank\" rel=\"noopener\">Ethyl Parathion<\/a><\/td><td class=\"oth\">16.89<\/td><td class=\"oth\">10<\/td><td class=\"oth\">109<\/td><td class=\"oth\">81<\/td><td class=\"oth\">10<\/td><td class=\"oth\">291<\/td><td class=\"oth\">81<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">129.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methapyrilene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-80-5\/Methapyrilene\" target=\"_blank\" rel=\"noopener\">Methapyrilene<\/a><\/td><td class=\"oth\">17.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">97<\/td><td class=\"oth\">53<\/td><td class=\"oth\">16<\/td><td class=\"oth\">190<\/td><td class=\"oth\">97<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">130.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isodrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/465-73-6\/Isodrin\" target=\"_blank\" rel=\"noopener\">Isodrin<\/a><\/td><td class=\"oth\">17.36<\/td><td class=\"oth\">10<\/td><td class=\"oth\">261<\/td><td class=\"oth\">226<\/td><td class=\"oth\">16<\/td><td class=\"oth\">261<\/td><td class=\"oth\">191<\/td><td class=\"oth\">28<\/td><\/tr>\n<tr><td class=\"num\">131.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/206-44-0\/Fluoranthene\" target=\"_blank\" rel=\"noopener\">Fluoranthene<\/a><\/td><td class=\"oth\">17.65<\/td><td class=\"oth\">10<\/td><td class=\"oth\">202<\/td><td class=\"oth\">176<\/td><td class=\"oth\">26<\/td><td class=\"oth\">184<\/td><td class=\"oth\">156<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">132.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/206-44-0\/Fluoranthene\" target=\"_blank\" rel=\"noopener\">Fluoranthene<\/a><\/td><td class=\"oth\">17.65<\/td><td class=\"oth\">10<\/td><td class=\"oth\">202<\/td><td class=\"oth\">152<\/td><td class=\"oth\">30<\/td><td class=\"oth\">200<\/td><td class=\"oth\">174<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">133.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92-87-5\/Benzidine\" target=\"_blank\" rel=\"noopener\">Benzidine<\/a><\/td><td class=\"oth\">17.99<\/td><td class=\"oth\">10<\/td><td class=\"oth\">184<\/td><td class=\"oth\">166<\/td><td class=\"oth\">16<\/td><td class=\"oth\">200<\/td><td class=\"oth\">149<\/td><td class=\"oth\">34<\/td><\/tr>\n<tr><td class=\"num\">134.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/129-00-0\/Pyrene\" target=\"_blank\" rel=\"noopener\">Pyrene<\/a><\/td><td class=\"oth\">18.08<\/td><td class=\"oth\">10<\/td><td class=\"oth\">200<\/td><td class=\"oth\">150<\/td><td class=\"oth\">26<\/td><td class=\"oth\">212<\/td><td class=\"oth\">208<\/td><td class=\"oth\">36<\/td><\/tr>\n<tr><td class=\"num\">135.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for p-Terphenyl-d14\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1718-51-0\/p-Terphenyl-d14\" target=\"_blank\" rel=\"noopener\">p-Terphenyl-d14<\/a><\/td><td class=\"oth\">18.5<\/td><td class=\"oth\">10<\/td><td class=\"oth\">244<\/td><td class=\"oth\">242<\/td><td class=\"oth\">14<\/td><td class=\"oth\">244<\/td><td class=\"oth\">240<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">136.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aramite 1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/140-57-8\/Aramite 1\" target=\"_blank\" rel=\"noopener\">Aramite 1<\/a><\/td><td class=\"oth\">18.55<\/td><td class=\"oth\">10<\/td><td class=\"oth\">319<\/td><td class=\"oth\">185<\/td><td class=\"oth\">6<\/td><td class=\"oth\">175<\/td><td class=\"oth\">107<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">137.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aramite 2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/140-57-8\/Aramite 2\" target=\"_blank\" rel=\"noopener\">Aramite 2<\/a><\/td><td class=\"oth\">18.7<\/td><td class=\"oth\">10<\/td><td class=\"oth\">185<\/td><td class=\"oth\">63<\/td><td class=\"oth\">12<\/td><td class=\"oth\">319<\/td><td class=\"oth\">185<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">138.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for p-Dimethylaminoazobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60-11-7\/p-Dimethylaminoazobenzene\" target=\"_blank\" rel=\"noopener\">p-Dimethylaminoazobenzene<\/a><\/td><td class=\"oth\">18.79<\/td><td class=\"oth\">10<\/td><td class=\"oth\">225<\/td><td class=\"oth\">148<\/td><td class=\"oth\">6<\/td><td class=\"oth\">120<\/td><td class=\"oth\">77<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">139.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorobenzilate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/510-15-6\/Chlorobenzilate\" target=\"_blank\" rel=\"noopener\">Chlorobenzilate<\/a><\/td><td class=\"oth\">18.93<\/td><td class=\"oth\">10<\/td><td class=\"oth\">251<\/td><td class=\"oth\">139<\/td><td class=\"oth\">12<\/td><td class=\"oth\">251<\/td><td class=\"oth\">111<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">140.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Famphur\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52-85-7\/Famphur\" target=\"_blank\" rel=\"noopener\">Famphur<\/a><\/td><td class=\"oth\">19.4<\/td><td class=\"oth\">10<\/td><td class=\"oth\">218<\/td><td class=\"oth\">109<\/td><td class=\"oth\">14<\/td><td class=\"oth\">125<\/td><td class=\"oth\">79<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">141.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3,3&amp;apos;-Dimethylbenzidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/119-93-7\/3,3&amp;apos;-Dimethylbenzidine\" target=\"_blank\" rel=\"noopener\">3,3&#8242;-Dimethylbenzidine<\/a><\/td><td class=\"oth\">19.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">211<\/td><td class=\"oth\">196<\/td><td class=\"oth\">8<\/td><td class=\"oth\">211<\/td><td class=\"oth\">195<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">142.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Kepone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/143-50-0\/Kepone\" target=\"_blank\" rel=\"noopener\">Kepone<\/a><\/td><td class=\"oth\">19.47<\/td><td class=\"oth\">10<\/td><td class=\"oth\">272<\/td><td class=\"oth\">237<\/td><td class=\"oth\">12<\/td><td class=\"oth\">237<\/td><td class=\"oth\">143<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">143.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzyl butyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85-68-7\/Benzyl butyl phthalate\" target=\"_blank\" rel=\"noopener\">Benzyl butyl phthalate<\/a><\/td><td class=\"oth\">19.56<\/td><td class=\"oth\">10<\/td><td class=\"oth\">206<\/td><td class=\"oth\">149<\/td><td class=\"oth\">8<\/td><td class=\"oth\">149<\/td><td class=\"oth\">121<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">144.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bis(2-ethylhexyl) adipate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/103-23-1\/Bis(2-ethylhexyl) adipate\" target=\"_blank\" rel=\"noopener\">Bis(2-ethylhexyl) adipate<\/a><\/td><td class=\"oth\">19.81<\/td><td class=\"oth\">10<\/td><td class=\"oth\">129<\/td><td class=\"oth\">55<\/td><td class=\"oth\">14<\/td><td class=\"oth\">129<\/td><td class=\"oth\">83<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">145.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Acetylaminofluorene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53-96-3\/2-Acetylaminofluorene\" target=\"_blank\" rel=\"noopener\">2-Acetylaminofluorene<\/a><\/td><td class=\"oth\">19.93<\/td><td class=\"oth\">10<\/td><td class=\"oth\">223<\/td><td class=\"oth\">181<\/td><td class=\"oth\">10<\/td><td class=\"oth\">181<\/td><td class=\"oth\">152<\/td><td class=\"oth\">34<\/td><\/tr>\n<tr><td class=\"num\">146.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benz[a]anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-55-3\/Benz[a]anthracene\" target=\"_blank\" rel=\"noopener\">Benz[a]anthracene<\/a><\/td><td class=\"oth\">20.5<\/td><td class=\"oth\">10<\/td><td class=\"oth\">228<\/td><td class=\"oth\">202<\/td><td class=\"oth\">22<\/td><td class=\"oth\">226<\/td><td class=\"oth\">200<\/td><td class=\"oth\">28<\/td><\/tr>\n<tr><td class=\"num\">147.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chrysene-d12\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1719-03-5\/Chrysene-d12\" target=\"_blank\" rel=\"noopener\">Chrysene-d12<\/a><\/td><td class=\"oth\">20.51<\/td><td class=\"oth\">10<\/td><td class=\"oth\">240<\/td><td class=\"oth\">238<\/td><td class=\"oth\">14<\/td><td class=\"oth\">240<\/td><td class=\"oth\">236<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">148.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3,3&amp;apos;-Dichlorobenzidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-94-1\/3,3&amp;apos;-Dichlorobenzidine\" target=\"_blank\" rel=\"noopener\">3,3&#8242;-Dichlorobenzidine<\/a><\/td><td class=\"oth\">20.51<\/td><td class=\"oth\">10<\/td><td class=\"oth\">252<\/td><td class=\"oth\">181<\/td><td class=\"oth\">22<\/td><td class=\"oth\">252<\/td><td class=\"oth\">182<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">149.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4,4&amp;apos;-Methylenebis(2-chloroaniline)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/101-14-4\/4,4&amp;apos;-Methylenebis(2-chloroaniline)\" target=\"_blank\" rel=\"noopener\">4,4&#8242;-Methylenebis(2-chloroaniline)<\/a><\/td><td class=\"oth\">20.53<\/td><td class=\"oth\">10<\/td><td class=\"oth\">231<\/td><td class=\"oth\">195<\/td><td class=\"oth\">16<\/td><td class=\"oth\">266<\/td><td class=\"oth\">231<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">150.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chrysene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/218-01-9\/Chrysene\" target=\"_blank\" rel=\"noopener\">Chrysene<\/a><\/td><td class=\"oth\">20.56<\/td><td class=\"oth\">10<\/td><td class=\"oth\">228<\/td><td class=\"oth\">202<\/td><td class=\"oth\">22<\/td><td class=\"oth\">228<\/td><td class=\"oth\">201<\/td><td class=\"oth\">36<\/td><\/tr>\n<tr><td class=\"num\">151.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bis(2-ethylhexyl) phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/117-81-7\/Bis(2-ethylhexyl) phthalate\" target=\"_blank\" rel=\"noopener\">Bis(2-ethylhexyl) phthalate<\/a><\/td><td class=\"oth\">20.78<\/td><td class=\"oth\">10<\/td><td class=\"oth\">167<\/td><td class=\"oth\">149<\/td><td class=\"oth\">8<\/td><td class=\"oth\">149<\/td><td class=\"oth\">121<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">152.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 6-Methylchrysene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1705-85-7\/6-Methylchrysene\" target=\"_blank\" rel=\"noopener\">6-Methylchrysene<\/a><\/td><td class=\"oth\">21.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">242<\/td><td class=\"oth\">226<\/td><td class=\"oth\">28<\/td><td class=\"oth\">239<\/td><td class=\"oth\">213<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">153.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Di-n-octyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/117-84-0\/Di-n-octyl phthalate\" target=\"_blank\" rel=\"noopener\">Di-n-octyl phthalate<\/a><\/td><td class=\"oth\">22.08<\/td><td class=\"oth\">10<\/td><td class=\"oth\">149<\/td><td class=\"oth\">121<\/td><td class=\"oth\">12<\/td><td class=\"oth\">149<\/td><td class=\"oth\">93<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">154.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[b]fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/205-99-2\/Benzo[b]fluoranthene\" target=\"_blank\" rel=\"noopener\">Benzo[b]fluoranthene<\/a><\/td><td class=\"oth\">22.68<\/td><td class=\"oth\">10<\/td><td class=\"oth\">252<\/td><td class=\"oth\">226<\/td><td class=\"oth\">22<\/td><td class=\"oth\">250<\/td><td class=\"oth\">224<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">155.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 7,12-Dimethylbenz[a]anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57-97-6\/7,12-Dimethylbenz[a]anthracene\" target=\"_blank\" rel=\"noopener\">7,12-Dimethylbenz[a]anthracene<\/a><\/td><td class=\"oth\">22.69<\/td><td class=\"oth\">10<\/td><td class=\"oth\">256<\/td><td class=\"oth\">241<\/td><td class=\"oth\">12<\/td><td class=\"oth\">241<\/td><td class=\"oth\">226<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">156.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[k]fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/207-08-9\/Benzo[k]fluoranthene\" target=\"_blank\" rel=\"noopener\">Benzo[k]fluoranthene<\/a><\/td><td class=\"oth\">22.74<\/td><td class=\"oth\">10<\/td><td class=\"oth\">252<\/td><td class=\"oth\">226<\/td><td class=\"oth\">22<\/td><td class=\"oth\">250<\/td><td class=\"oth\">224<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">157.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[a]pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-32-8\/Benzo[a]pyrene\" target=\"_blank\" rel=\"noopener\">Benzo[a]pyrene<\/a><\/td><td class=\"oth\">23.41<\/td><td class=\"oth\">10<\/td><td class=\"oth\">252<\/td><td class=\"oth\">226<\/td><td class=\"oth\">22<\/td><td class=\"oth\">250<\/td><td class=\"oth\">224<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">158.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perylene-d12\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1520-96-3\/Perylene-d12\" target=\"_blank\" rel=\"noopener\">Perylene-d12<\/a><\/td><td class=\"oth\">23.55<\/td><td class=\"oth\">10<\/td><td class=\"oth\">264<\/td><td class=\"oth\">262<\/td><td class=\"oth\">20<\/td><td class=\"oth\">264<\/td><td class=\"oth\">260<\/td><td class=\"oth\">34<\/td><\/tr>\n<tr><td class=\"num\">159.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3-Methylcholanthrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-49-5\/3-Methylcholanthrene\" target=\"_blank\" rel=\"noopener\">3-Methylcholanthrene<\/a><\/td><td class=\"oth\">24.32<\/td><td class=\"oth\">10<\/td><td class=\"oth\">268<\/td><td class=\"oth\">253<\/td><td class=\"oth\">14<\/td><td class=\"oth\">252<\/td><td class=\"oth\">226<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">160.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenz(a,h)acridine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/226-36-8\/Dibenz(a,h)acridine\" target=\"_blank\" rel=\"noopener\">Dibenz(a,h)acridine<\/a><\/td><td class=\"oth\">25.8<\/td><td class=\"oth\">10<\/td><td class=\"oth\">279<\/td><td class=\"oth\">252<\/td><td class=\"oth\">34<\/td><td class=\"oth\">278<\/td><td class=\"oth\">250<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">161.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenz[a,j]acridine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/224-42-0\/Dibenz[a,j]acridine\" target=\"_blank\" rel=\"noopener\">Dibenz[a,j]acridine<\/a><\/td><td class=\"oth\">25.88<\/td><td class=\"oth\">10<\/td><td class=\"oth\">279<\/td><td class=\"oth\">277<\/td><td class=\"oth\">30<\/td><td class=\"oth\">278<\/td><td class=\"oth\">250<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">162.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Indeno[1,2,3-cd]pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/193-39-5\/Indeno[1,2,3-cd]pyrene\" target=\"_blank\" rel=\"noopener\">Indeno[1,2,3-cd]pyrene<\/a><\/td><td class=\"oth\">26.32<\/td><td class=\"oth\">10<\/td><td class=\"oth\">138<\/td><td class=\"oth\">125<\/td><td class=\"oth\">12<\/td><td class=\"oth\">276<\/td><td class=\"oth\">250<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">163.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenz[a,h]anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53-70-3\/Dibenz[a,h]anthracene\" target=\"_blank\" rel=\"noopener\">Dibenz[a,h]anthracene<\/a><\/td><td class=\"oth\">26.43<\/td><td class=\"oth\">10<\/td><td class=\"oth\">139<\/td><td class=\"oth\">126<\/td><td class=\"oth\">8<\/td><td class=\"oth\">139<\/td><td class=\"oth\">113<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">164.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[ghi]perylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/191-24-2\/Benzo[ghi]perylene\" target=\"_blank\" rel=\"noopener\">Benzo[ghi]perylene<\/a><\/td><td class=\"oth\">27.05<\/td><td class=\"oth\">10<\/td><td class=\"oth\">138<\/td><td class=\"oth\">125<\/td><td class=\"oth\">12<\/td><td class=\"oth\">138<\/td><td class=\"oth\">124<\/td><td class=\"oth\">28<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>RMX-5Sil MS, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/17323\" rel=\"noopener\">cat.# 17323<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>SVOC MegaMix 150 kit (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31907\" rel=\"noopener\">cat.# 31907<\/a>)<\/td><\/tr><tr><td><\/td><td>Revised SV internal standard mix (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31886\" rel=\"noopener\">cat.# 31886<\/a>)<\/td><\/tr><tr><td><\/td><td>Base neutral surrogate mix (4\/89 SOW) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31024\" rel=\"noopener\">cat.# 31024<\/a>)<\/td><\/tr><tr><td><\/td><td>Acid surrogate mix (4\/89 SOW) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31025\" rel=\"noopener\">cat.# 31025<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Dichloromethane<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>100 ppb <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 10:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 4.0 mm ID Precision liner w\/wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23267\" rel=\"noopener\">cat.# 23267<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Split Vent Flow Rate:<\/th><td>12 mL\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>40 &#176;C (hold 1 min) to 280 &#176;C at 12 &#176;C\/min to 310 &#176;C at 3 &#176;C\/min (hold 1 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.2 mL\/min @ 40 \u00b0C<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>SRM\/MRM<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>330 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Triple Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Collision Gas:<\/th><td>Ar <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>PFTBA <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Emission Current:<\/th><td>70 \u03bcA<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Thermo Scientific TSQ 8000 Triple Quadrupole GC-MS<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Standards were combined and diluted to a concentration of 100 ppb.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31907<\/li><li>31886<\/li><li>31024<\/li><li>31025<\/li><li>17323<\/li><li>23267<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>8270<\/li><li>8270e<\/li><li>RMX-library<\/li><li>environmental<\/li><li>semivolatile<\/li><li>semivolatiles-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1527.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> Highly inert RMX-5Sil MS columns help you meet data requirements for a wide range of challenging semivolatiles at extremely low levels.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1526.png\" alt=\"Select Semivolatiles at Low Levels on RMX-5Sil MS by GC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1526<\/p><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>RMX-5Sil MS, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/17323\" rel=\"noopener\">cat.# 17323<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>SVOC MegaMix 150 kit (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31907\" rel=\"noopener\">cat.# 31907<\/a>)<\/td><\/tr><tr><td><\/td><td>Revised SV internal standard mix (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31886\" rel=\"noopener\">cat.# 31886<\/a>)<\/td><\/tr><tr><td><\/td><td>Base neutral surrogate mix (4\/89 SOW) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31024\" rel=\"noopener\">cat.# 31024<\/a>)<\/td><\/tr><tr><td><\/td><td>Acid surrogate mix (4\/89 SOW) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31025\" rel=\"noopener\">cat.# 31025<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Dichloromethane<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>1, 10, 100 ppb <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 10:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 4.0 mm ID Precision liner w\/wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23267\" rel=\"noopener\">cat.# 23267<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Split Vent Flow Rate:<\/th><td>12 mL\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>40 &#176;C (hold 1 min) to 280 &#176;C at 12 &#176;C\/min to 310 &#176;C at 3 &#176;C\/min (hold 1 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.2 mL\/min @ 40 \u00b0C<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>SRM\/MRM<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>330 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Triple Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Collision Gas:<\/th><td>Ar <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>PFTBA <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Emission Current:<\/th><td>70 \u03bcA<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Thermo Scientific TSQ 8000 Triple Quadrupole GC-MS<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31907<\/li><li>31886<\/li><li>31024<\/li><li>31025<\/li><li>17323<\/li><li>23267<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>RMX-library<\/li><li>semivolatiles<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1526.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>References<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>RMX GC columns brochure, GNBR4923-UNV, Restek Corporation, 2026. <a href=\"https:\/\/discover.restek.com\/articles\/gnbr4923\/rmx-gc-columns-unleash-your-performance\">https:\/\/discover.restek.com\/articles\/gnbr4923\/rmx-gc-columns-unleash-your-performance<\/a><\/li>\n\n\n\n<li>E. Pack, J. Hoisington, C. English, R. Dhandapani, and C. Myers, Comprehensive trace-level semivolatiles analysis by GC-MS\/MS (EPA Method 8270E), Application note, EVAN4919-US, Restek Corporation, 2025. <a href=\"https:\/\/discover.restek.com\/application-notes\/evan4919\/comprehensive-trace-level-gc-ms-ms-semivolatiles-method-epa-method-8270e\">https:\/\/discover.restek.com\/application-notes\/evan4919\/comprehensive-trace-level-gc-ms-ms-semivolatiles-method-epa-method-8270e<\/a><\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><a href=\"https:\/\/discover.restek.com\/articles\/GNOT3445\/ezgc-online-tools\"><img loading=\"lazy\" decoding=\"async\" width=\"1340\" height=\"312\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up.png\" alt=\"EZGC software ad\" class=\"wp-image-61667\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up.png 1340w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up-300x70.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up-1024x238.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up-768x179.png 768w\" sizes=\"auto, (max-width: 1340px) 100vw, 1340px\" \/><\/a><\/figure>\n<\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><a href=\"https:\/\/discover.restek.com\/RMX\"><img loading=\"lazy\" decoding=\"async\" width=\"1340\" height=\"1220\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1.png\" alt=\"RMX benefits graphic\" class=\"wp-image-61438\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1.png 1340w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-300x273.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-1024x932.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-768x699.png 768w\" sizes=\"auto, (max-width: 1340px) 100vw, 1340px\" \/><\/a><\/figure>\n<\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Products Mentioned<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/17323\">                                Catalog No. 17323                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">RMX-5Sil MS GC Capillary Column, 30 m, 0.25 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/17323\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23267\">                                Catalog No. 23267                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Precision Inlet Liner, 4.0 mm x 6.3 x 78.5, for Thermo TRACE 1300\/1310, 1600\/1610 GCs w\/SSL Inlets, Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23267\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">                                Catalog No. 28500                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Restek Electronic Leak Detector<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31907\">                                Catalog No. 31907                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">SVOC MegaMix 150 Kit, 1 mL\/ampul; 6 ampuls\/kit<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31907\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31615\">                                Catalog No. 31615                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">GC-MS Tuning Mix, 1000 \u00b5g\/mL, Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31615\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31025\">                                Catalog No. 31025                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Acid Surrogate Mix (4\/89 SOW), 2000 \u00b5g\/mL, Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31025\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31024\">                                Catalog No. 31024                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Base Neutral Surrogate Mix (4\/89 SOW), 1000 \u00b5g\/mL, Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31024\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31886\">                                Catalog No. 31886                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Revised SV Internal Standard Mix, 4000 \u00b5g\/mL, Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31886\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Maximize lab productivity with this expanded trace-level semivolatiles method for 150 target analytes. Broadly effective, RMX-5Sil MS columns help you meet data quality requirements down to 0.1 pg on-column for a wide range of challenging semivolatiles.<\/p>\n","protected":false},"author":34,"featured_media":62374,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[7],"tags":[2738],"industries-application":[2163,2161,2668,2166],"post-badge":[29],"resource-type":[2623],"product-library":[2372,2384],"resource-technique":[2294,2301,2302],"ppma_author":[454,441,2657,452],"class_list":["post-61373","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles","tag-rmx-resources","industries-application-drinking-water-wastewater-testing","industries-application-environmental","industries-application-semivolatiles","industries-application-soil-sediment-biota-testing","post-badge-new","resource-type-featured-application","product-library-gas-chromatography-products","product-library-gc-columns","resource-technique-gas-chromatography-gc","resource-technique-mass-spectrometry-ms","resource-technique-ms-ms"],"acf":[],"taxonomy_info":{"category":[{"value":7,"label":"Articles"}],"post_tag":[{"value":2738,"label":"RMX Resources"}],"industries-application":[{"value":2163,"label":"Drinking Water &amp; Wastewater Testing"},{"value":2161,"label":"Environmental"},{"value":2668,"label":"Semivolatiles"},{"value":2166,"label":"Soil, Sediment, Biota Testing"}],"post-badge":[{"value":29,"label":"New"}],"resource-type":[{"value":2623,"label":"Featured Application"}],"product-library":[{"value":2372,"label":"Gas Chromatography Products"},{"value":2384,"label":"GC Columns"}],"resource-technique":[{"value":2294,"label":"Gas Chromatography (GC)"},{"value":2301,"label":"Mass Spectrometry (MS)"},{"value":2302,"label":"MS\/MS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVFA5253-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Erica Pack, PhD","author_link":"https:\/\/discover.restek.com\/es\/author\/erica-pack-phd\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":7,"category_count":510,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":[{"term_id":2738,"name":"RMX Resources","slug":"rmx-resources","term_group":0,"term_taxonomy_id":2738,"taxonomy":"post_tag","description":"Explore RMX Resources Now","parent":0,"count":23,"filter":"raw"}],"authors":[{"term_id":454,"user_id":34,"is_guest":0,"slug":"erica-pack-phd","display_name":"Erica Pack, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg"},"author_category":"1","first_name":"Erica","last_name":"Pack","user_url":"https:\/\/www.linkedin.com\/in\/ericapack\/","job_title":"Senior Scientist, GC Applied","description":"Erica is an interdisciplinary GC applications and technologies scientist at Restek. She obtained her bachelor's degree in forensic biology from The Pennsylvania State University, and her doctorate from Virginia Tech in plant pathology, physiology, and weed science. Since joining Restek in 2021, she has worked with a wide variety of GC columns, including fused silica, MXT, PLOT, and packed columns as well as accessories, such as liners, valves, and methanizers."},{"term_id":441,"user_id":21,"is_guest":0,"slug":"chris-english","display_name":"Chris English","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-english-chris.png","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-english-chris.png"},"author_category":"1","first_name":"Chris","last_name":"English","user_url":"https:\/\/www.linkedin.com\/in\/chris-english-28214912\/","job_title":"Sr. R&D Manager","description":"Since 2004, Chris has managed a team of chemists in Restek's innovations laboratory who perform new product testing, method development, and applications work. Before taking the reins of our lab, he spent seven years as an environmental chemist and was critical to the development of Restek\u2019s current line of volatile GC columns. Prior to joining Restek, he operated a variety of gas chromatographic detectors conducting method development and sample analysis. Chris holds a BS in environmental science from Saint Michael's College."},{"term_id":2657,"user_id":70,"is_guest":0,"slug":"ramkumar-dhandapani-phd","display_name":"Ramkumar Dhandapani, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Dhandapani_Ramkumar_Profile.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Dhandapani_Ramkumar_Profile.jpg"},"author_category":"1","first_name":"Ramkumar","last_name":"Dhandapani","user_url":"https:\/\/www.linkedin.com\/in\/dr-ramkumar-dhandapani-b9012424\/?skipRedirect=true&enhance=null","job_title":"Director of Product Management","description":"Dr. Ramkumar Dhandapani\u00a0is a seasoned analytical chemist with over\u00a023 years of experience\u00a0in the chromatography industry and a Ph.D. in analytical chemistry. During his career, he has specialized in method development, validation, and the troubleshooting of chromatography methods. He has developed numerous regulatory-compliant methods across diverse sectors, including\u00a0environmental analysis, food quality and safety, pharmaceutical, fuels, and chemical industries. Currently, Dr. Dhandapani is the Director of Product Management at Restek, he is keen on innovation in chromatography and scaling breakthrough innovations\u00a0to market as commercial products."},{"term_id":452,"user_id":32,"is_guest":0,"slug":"colton-myers","display_name":"Colton Myers","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg"},"author_category":"1","first_name":"Colton","last_name":"Myers","user_url":"https:\/\/www.linkedin.com\/in\/myerscolton\/","job_title":"Product Manager - New Product Development","description":"Colton Myers is a Product Manager for GC columns at Restek Corporation with over 10 years of experience in research and development. He specializes in driving new GC column technologies from concept to market, combining deep technical expertise with a strong focus on innovation and commercialization. Colton holds a BS in chemistry from Juniata College and a Master of Management in Corporate Innovation and Entrepreneurship from Penn State University."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/61373","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/users\/34"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/comments?post=61373"}],"version-history":[{"count":48,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/61373\/revisions"}],"predecessor-version":[{"id":105093,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/61373\/revisions\/105093"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media\/62374"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media?parent=61373"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/categories?post=61373"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/tags?post=61373"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/industries-application?post=61373"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/post-badge?post=61373"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-type?post=61373"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/product-library?post=61373"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-technique?post=61373"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/ppma_author?post=61373"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}