{"id":84082,"date":"2026-01-22T21:22:48","date_gmt":"2026-01-22T21:22:48","guid":{"rendered":"https:\/\/discover.restek.com\/?p=84082"},"modified":"2026-01-22T21:22:50","modified_gmt":"2026-01-22T21:22:50","slug":"using-a-virtual-liquid-chromatography-tool-to-develop-methods-for-novel-psychoactive-substances-4","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/es\/posters-presentations-fr\/gnot5376\/using-a-virtual-liquid-chromatography-tool-to-develop-methods-for-novel-psychoactive-substances-4","title":{"rendered":"Using a Virtual Liquid Chromatography Tool to Develop Methods for Novel Psychoactive Substances"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Novel psychoactive substances (NPS) have created a challenge for toxicology laboratories. New NPS are constantly disappearing as fast as they emerge, making it difficult to stay on top of which compounds are necessary to add to laboratory testing scopes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The development and optimization of liquid chromatography (LC) separations is time-consuming and costly, often requiring several steps including literature research, column selection, method scouting, method development, and method optimization.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To alleviate the burden of sacrificing instrument-uptime, labor and materials, an instrument-free software modeling tool was developed to include a comprehensive drugs of abuse (DoA) library. Users can obtain optimized separations while maintaining critical pair resolution by adjusting parameters, such as column dimension, mobile phase, gradient programs, and more, for almost 300 compounds, including the 38 newly added NPS drugs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The primary objective of this study was to use a chromatographic modeling tool to develop effective LC-MS\/MS methods for various NPS compounds, including synthetic opioids, designer benzodiazepines, synthetic cathinones, synthetic cannabinoids, and toxic adulterants.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The online chromatogram modeling tool successfully developed methods for NPS compounds. Developing the methods using the virtual chromatography tool was completed in under ten minutes per method, and based on the acceptance criteria as defined, each NPS method was successfully transferred from the virtual model to an LC-MS\/MS instrument.<\/p>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/discover.restek.com\/wp-content\/uploads\/poster-tiaft-2024-Using-a-Virtual-Chromatography-Tool-to-Develop-Methods-for-Novel-Psychoactive-Substances.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"Embed of poster-tiaft-2024-Using a Virtual Chromatography Tool to Develop Methods for Novel Psychoactive Substances.\"><\/object><a id=\"wp-block-file--media-7fa4435a-a37a-4ac9-9db1-36519b69027d\" href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/poster-tiaft-2024-Using-a-Virtual-Chromatography-Tool-to-Develop-Methods-for-Novel-Psychoactive-Substances.pdf\">poster-tiaft-2024-Using a Virtual Chromatography Tool to Develop Methods for Novel Psychoactive Substances<\/a><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/poster-tiaft-2024-Using-a-Virtual-Chromatography-Tool-to-Develop-Methods-for-Novel-Psychoactive-Substances.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-7fa4435a-a37a-4ac9-9db1-36519b69027d\">Download<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Novel psychoactive substances (NPS) have created a challenge for toxicology laboratories. New NPS are constantly disappearing as fast as they emerge, making it difficult to stay on top of which compounds are necessary to add to laboratory testing scopes. The development and optimization of liquid chromatography (LC) separations is time-consuming and costly, often requiring several&#8230;<\/p>\n","protected":false},"author":13,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[812],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[647,432,459,702,579],"class_list":["post-84082","post","type-post","status-publish","format-standard","hentry","category-posters-presentations-fr"],"acf":[],"taxonomy_info":{"category":[{"value":812,"label":"Posters &amp; Presentations"}]},"featured_image_src_large":false,"author_info":{"display_name":"Haley Berkland, MS","author_link":"https:\/\/discover.restek.com\/es\/author\/haley-berkland-ms\/"},"comment_info":0,"category_info":[{"term_id":812,"name":"Posters &amp; Presentations","slug":"posters-presentations-fr","term_group":0,"term_taxonomy_id":812,"taxonomy":"category","description":"","parent":0,"count":125,"filter":"raw","cat_ID":812,"category_count":125,"category_description":"","cat_name":"Posters &amp; Presentations","category_nicename":"posters-presentations-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":647,"user_id":0,"is_guest":1,"slug":"cyrille-lamboley","display_name":"Cyrille Lamboley","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Cyrille","last_name":"Lamboley","user_url":"","job_title":"","description":""},{"term_id":432,"user_id":13,"is_guest":0,"slug":"haley-berkland-ms","display_name":"Haley Berkland, MS","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg"},"author_category":"1","first_name":"Haley","last_name":"Berkland","user_url":"https:\/\/www.linkedin.com\/in\/haley-berkland-60b66517b\/","job_title":"LC Applications Scientist","description":"Haley is an LC applications scientist at Restek. She attended Duquesne University, receiving her bachelor's degree in biochemistry and a master's degree in forensic science and law. As a graduate student, she performed research on the detection of drugs of abuse in vitreous humor by LC-MS\/MS. Before joining Restek in 2023, Haley spent four years working as a forensic toxicologist. While in this role, she performed analysis of postmortem toxicology casework, identification of seized drug evidence, and development\/validation of new assays by LC-MS\/MS, GC-MS, and GC-FID."},{"term_id":459,"user_id":39,"is_guest":0,"slug":"melinda-urich","display_name":"Melinda Urich","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-ulrich-melinda.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-ulrich-melinda.jpg"},"author_category":"1","first_name":"Melinda","last_name":"Urich","user_url":"https:\/\/www.linkedin.com\/in\/melinda-urich-997b81225\/","job_title":"Advanced Scientist, LC Solutions","description":"Melinda \u201cMel\u201d Urich is an applications scientist in the LC Solutions department. Her primary focus is on the development of novel applications in the cannabis and food markets. In her previous role at Restek as an LC manufacturing chemist, she led the synthesis of silica, bonding of stationary phases as well as new process implementations and improvements. Mel attended Juniata College where she earned her BS in Chemistry and performed research in Atomic Force Microscopy AFM)."},{"term_id":702,"user_id":0,"is_guest":1,"slug":"justin-steimling","display_name":"Justin Steimling","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Justin","last_name":"Steimling","user_url":"https:\/\/www.linkedin.com\/in\/justin-steimling-959729167\/","job_title":"R&D, LC Solutions","description":""},{"term_id":579,"user_id":47,"is_guest":0,"slug":"jamie-l-york-phd","display_name":"Jamie L. York, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/york-jamie-1000x1000-1-e1765483005988.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/york-jamie-1000x1000-1-e1765483005988.jpg"},"author_category":"1","first_name":"Jamie","last_name":"York","user_url":"https:\/\/www.linkedin.com\/in\/jamielyork\/","job_title":"Principal Scientist, LC Solutions","description":"Jamie York is a principal scientist in the Applications Lab at Restek Corporation. She leads the development of innovative analytical methods tailored to the food, clinical, environmental, and cannabis markets. Jamie earned her PhD in chemistry from The University of Texas at Arlington, where she gained extensive expertise in a range of analytical techniques, including gas chromatography\u2013vacuum ultraviolet (GC\u2013VUV); gas chromatography\u2013mass spectrometry (GC\u2013MS); matrix-assisted laser desorption\/ionization (MALDI); and liquid chromatography\u2013 mass spectrometry (LC\u2013MS\/MS); with a research emphasis on food and environmental analysis. Today, her work focuses on complex method development and advanced sample preparation strategies to support the evolving needs of the scientific community."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/84082","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/comments?post=84082"}],"version-history":[{"count":1,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/84082\/revisions"}],"predecessor-version":[{"id":84084,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/84082\/revisions\/84084"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media?parent=84082"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/categories?post=84082"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/tags?post=84082"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/industries-application?post=84082"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/post-badge?post=84082"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-type?post=84082"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/product-library?post=84082"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-technique?post=84082"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/ppma_author?post=84082"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}