Articles

VFC Analysis by U.S. EPA Method OTM-50 for Emissions

03 Oct 2025

feature EVAR4331
  • Sample Matrix: emissions from stationary sources
  • Sample Preparation: collection in passivated stainless-steel canisters
  • Detection Technique: GC-MS

Other Test Method 50 (OTM-50): Sampling and Analysis of Volatile Fluorinated Compounds from Stationary Sources Using Passivated Stainless-Steel Canisters

U.S. EPA Method OTM-50 is a performance-based draft method that can be used for the analysis of 30 volatile fluorinated compounds (VFC) in air emissions from stationary sources. It includes multiple short-chain VFC, which may be monitored as indicators of incomplete PFAS decomposition. Emission samples are collected in passivated stainless-steel canisters and then analyzed by GC-MS using a PLOT column. Draft Method OTM-50 was released to encourage a consistent process for facilities, stationary source test teams, research laboratories, and other stakeholders and to promote discussion and further evaluation of the method. The full analyte list and recommended products for collecting volatile fluorinated compounds in emissions for analysis by Method OTM-50 are provided below. 

Analyte List for EPA Method OTM-50 for Volatile Fluorinated Compounds in Emissions

Compound NameCAS#
Carbon tetrafluoride75-73-0
Hexafluoroethane (FC-116)76-16-4
Tetrafluoroethene116-14-3
Trifluoromethane (HFC-23)75-46-7
Octafluoropropane76-19-7
Difluoromethane (HFC-32)75-10-5
Fluoromethane (HFC-41)593-53-3
Pentafluoroethane (HFC-125)354-33-6
Hexafluoropropene116-15-4
Hexafluoropropene oxide (HFPO)428-59-1
Decafluorobutane355-25-9
Dodecafluoropentane678-26-2
Tetradecafluorohexane355-42-0
1H-Perfluoropentane375-61-1
Hexadecafluoroheptane335-57-9
Heptafluoropropyl-1,2,2,2-tetrafluoroethyl ether (E1)3330-15-2
1H-Perfluorohexane355-37-3
1H-Perfluoroheptane375-83-7
2H-Perfluoro-5-methyl-3,6-dioxanonane (E2)3330-14-1
1H-Perfluorooctane335-65-9
Octadecafluorooctane307-34-6
1H-Nonafluorobutane375-17-7
1H-Heptafluoropropane2252-84-8
1,1,1,2-Tetrafluoroethane (HFC-134a)811-97-2
1,1,1-Trifluoroethane (HFC-143a)420-46-2
Chlorodifluoromethane (HCFC-22)75-45-6
Chlorotrifluoromethane (CFC-13)75-72-9
Octafluorocyclobutane (FC-C318)115-25-3
Octafluorocyclopentene (FC-C1418)559-40-0
Trichloromonofluoromethane (CFC-11)75-69-4

Recommended Products for EPA Method OTM-50 for Volatile Fluorinated Compounds in Emissions

Sample Collection


Canister SilcoCan pour échantillonnage d'air, 6 litres, avec vanne RAVE+ 3 voies traitée Siltek avec manomètre
Canister SilcoCan pour échantillonnage d'air, 6 litres, avec vanne RAVE+ 2 voies traitée Siltek
Canister SilcoCan pour échantillonnage d'air, 6 litres, sans vanne
Canister TO-Can pour échantillonnage d'air, 6 litres, avec vanne RAVE+ 3 voies avec manomètre
Canister TO-Can pour échantillonnage d'air, 6 litres, avec vanne RAVE+ 2 voies
Canister TO-Can pour échantillonnage d'air, 6 litres, sans vanne

Discover More Solutions for PFAS Analysis!

Start Saving
Time Today

Develop PFAS Methods in Minutes with our Pro EZLC Chromatogram Modeler

Start Saving Time Today

Develop PFAS Methods in Minutes with our Pro EZLC Chromatogram Modeler

Tags

Auteurs

  • Restek Corporation

    Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions.

    View Articles
EVAR4331
Version : A