{"id":3439,"date":"2025-07-31T16:43:48","date_gmt":"2025-07-31T16:43:48","guid":{"rendered":"https:\/\/discover.restek.com\/?p=3439"},"modified":"2025-12-08T23:28:54","modified_gmt":"2025-12-08T23:28:54","slug":"how-do-i-install-a-gc-column-into-the-new-flip-seal-adaptor-nut","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/faq\/gnot4962\/how-do-i-install-a-gc-column-into-the-new-flip-seal-adaptor-nut","title":{"rendered":"How do I install a GC column into the new Flip Seal adaptor nut?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Insert the GC column through the 1\/16\u201d adaptor sealing nut and a standard 1\/16\u201d graphite or graphite-Vespel capillary ferrule. Make a clean cut across the GC column. Install the column into the adaptor 30-32 mm from the bottom of the 1\/16\u201d nut, which places the column end a few millimeters above the bottom of the inlet seal, the perfect installation distance! Don\u2019t forget to leak check with a Restek Electronic Leak Detector (<a href=\"https:\/\/www.restek.com\/p\/28500\" target=\"_blank\" rel=\"noopener\">cat.# 28500<\/a>) after tightening the adaptor nut to seal the GC column to the inlet and re-pressurizing the inlet.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"900\" height=\"367\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3285-04.jpg\" alt=\"Column sealing nut shown 30-32 mm from the end of the column.\" class=\"wp-image-21160\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3285-04.jpg 900w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3285-04-300x122.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3285-04-768x313.jpg 768w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Seat the column sealing nut so that<br>the bottom is 30-32 mm from<br>the end of the column.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"900\" height=\"819\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3285-05.jpg\" alt=\"Column being inserted into the adaptor fitting.\" class=\"wp-image-21166\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3285-05.jpg 900w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3285-05-300x273.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3285-05-768x699.jpg 768w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Insert the column into the adaptor fitting.<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"900\" height=\"819\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3285-06.jpg\" alt=\"Sealing nut being tightened onto the adaptor fitting.\" class=\"wp-image-35975\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3285-06.jpg 900w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3285-06-300x273.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3285-06-768x699.jpg 768w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Tighten the sealing nut onto the adaptor fitting.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"900\" height=\"819\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3285-01.jpg\" alt=\"Flip Seal inlet seal in adaptor fitting.\" class=\"wp-image-21142\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3285-01.jpg 900w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3285-01-300x273.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR3285-01-768x699.jpg 768w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Perfect installation distance for column in adaptor fitting.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Insert the GC column through the 1\/16\u201d adaptor sealing nut and a standard 1\/16\u201d graphite or graphite-Vespel capillary ferrule. Make a clean cut across the GC column. Install the column into the adaptor 30-32 mm from the bottom of the 1\/16\u201d nut, which places the column end a few millimeters above the bottom of the&#8230;<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[23],"tags":[2680],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-3439","post","type-post","status-publish","format-standard","hentry","category-faq","tag-faq-flip-seal-inlet-seals"],"acf":[],"taxonomy_info":{"category":[{"value":23,"label":"FAQ"}],"post_tag":[{"value":2680,"label":"FAQ: Flip Seal Inlet Seals"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":23,"name":"FAQ","slug":"faq","term_group":0,"term_taxonomy_id":23,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":23,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq","category_parent":0}],"tag_info":[{"term_id":2680,"name":"FAQ: Flip Seal Inlet Seals","slug":"faq-flip-seal-inlet-seals","term_group":0,"term_taxonomy_id":2680,"taxonomy":"post_tag","description":"Browse frequently asked questions for flip seal inlet seals.","parent":0,"count":8,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/3439","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=3439"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/3439\/revisions"}],"predecessor-version":[{"id":70490,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/3439\/revisions\/70490"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=3439"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=3439"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=3439"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=3439"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=3439"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=3439"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=3439"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=3439"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=3439"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}