{"id":3478,"date":"2025-07-31T18:00:14","date_gmt":"2025-07-31T18:00:14","guid":{"rendered":"https:\/\/discover.restek.com\/?p=3478"},"modified":"2026-01-27T18:50:34","modified_gmt":"2026-01-27T18:50:34","slug":"what-is-the-difference-between-a-to-can-and-a-silcocan-canister","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/faq\/gnot4977\/what-is-the-difference-between-a-to-can-and-a-silcocan-canister","title":{"rendered":"What is the difference between a TO-Can and a SilcoCan canister?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Restek\u2019s\u00a0<a href=\"https:\/\/www.restek.com\/c\/TO-Can\" target=\"_blank\" rel=\"noreferrer noopener\">TO-Can canisters<\/a>\u00a0(toxic organics) are general-purpose canisters that are intended to be used for methods such as\u00a0<a href=\"https:\/\/www3.epa.gov\/ttnamti1\/files\/ambient\/airtox\/to-14ar.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">TO-14A<\/a>,\u00a0<a href=\"https:\/\/www3.epa.gov\/ttnamti1\/files\/ambient\/airtox\/to-15r.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">TO-15<\/a>, IP-1A, ASTM D5466, OSHA PV 2120, and NJ DEP Low Level TO-15. These canisters feature a proprietary electropolished surface that is designed to maintain compound stability. TO-Can canisters are functional equivalents to \u201cSUMMA\u201d canisters.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.restek.com\/c\/SilcoCan\" target=\"_blank\" rel=\"noreferrer noopener\">SilcoCan canisters<\/a>\u00a0are\u00a0<a href=\"https:\/\/discover.restek.com\/tag\/faq-surface-treatments\/\">Siltek\u00a0<\/a>treated and are more inert than TO-Can canisters. They are ideal for low-level reactive sulfurs (5\u201320 ppb) as well as some of the more challenging\u00a0<a href=\"https:\/\/www3.epa.gov\/ttnamti1\/files\/ambient\/airtox\/to-14ar.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">TO-14A<\/a>\u00a0and\u00a0<a href=\"https:\/\/www3.epa.gov\/ttnamti1\/files\/ambient\/airtox\/to-15r.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">TO-15<\/a>\u00a0compounds. These\u00a0<a href=\"https:\/\/discover.restek.com\/tag\/faq-surface-treatments\/\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/tag\/faq-surface-treatments\/\">Siltek-treated<\/a>\u00a0canisters are typically recommended for the collection and storage of sulfur-containing or brominated compounds. Siltek-treated\u00a0<a href=\"https:\/\/www.restek.com\/search\/canisters-accessories\/_\/N-1848608355?Ns=bestMatch&amp;NttWithIn=siltek\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/search\/canisters-accessories\/_\/N-1848608355?Ns=bestMatch&amp;NttWithIn=siltek\" rel=\"noreferrer noopener\">accessories<\/a> should be used with these canisters to provide the most inert sampling pathway.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Restek\u2019s\u00a0TO-Can canisters\u00a0(toxic organics) are general-purpose canisters that are intended to be used for methods such as\u00a0TO-14A,\u00a0TO-15, IP-1A, ASTM D5466, OSHA PV 2120, and NJ DEP Low Level TO-15. These canisters feature a proprietary electropolished surface that is designed to maintain compound stability. TO-Can canisters are functional equivalents to \u201cSUMMA\u201d canisters. SilcoCan canisters\u00a0are\u00a0Siltek\u00a0treated and are more&#8230;<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[2808],"tags":[2677,2691],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2371,2377],"resource-technique":[],"ppma_author":[414],"class_list":["post-3478","post","type-post","status-publish","format-standard","hentry","category-faq","tag-faq-air-sampling","tag-faq-air-sampling-canisters","product-library-air-gas-sampling-products","product-library-canisters-accessories"],"acf":[],"taxonomy_info":{"category":[{"value":2808,"label":"FAQ"}],"post_tag":[{"value":2677,"label":"FAQ: Air Sampling"},{"value":2691,"label":"FAQ: Air Sampling Canisters"}],"product-library":[{"value":2371,"label":"Air &amp; Gas Sampling Products"},{"value":2377,"label":"Canisters &amp; Accessories"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":2808,"name":"FAQ","slug":"faq","term_group":0,"term_taxonomy_id":2808,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":2808,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq","category_parent":0}],"tag_info":[{"term_id":2677,"name":"FAQ: Air Sampling","slug":"faq-air-sampling","term_group":0,"term_taxonomy_id":2677,"taxonomy":"post_tag","description":"Browse frequently asked questions for air sampling products.","parent":0,"count":36,"filter":"raw"},{"term_id":2691,"name":"FAQ: Air Sampling Canisters","slug":"faq-air-sampling-canisters","term_group":0,"term_taxonomy_id":2691,"taxonomy":"post_tag","description":"Browse frequently asked questions for air sampling canisters.","parent":0,"count":5,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/3478","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=3478"}],"version-history":[{"count":7,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/3478\/revisions"}],"predecessor-version":[{"id":84954,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/3478\/revisions\/84954"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=3478"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=3478"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=3478"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=3478"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=3478"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=3478"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=3478"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=3478"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=3478"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}