{"id":3489,"date":"2025-07-31T18:09:08","date_gmt":"2025-07-31T18:09:08","guid":{"rendered":"https:\/\/discover.restek.com\/?p=3489"},"modified":"2025-12-08T18:58:14","modified_gmt":"2025-12-08T18:58:14","slug":"can-restek-repair-canisters-and-controllers","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/faq\/gnot4979\/can-restek-repair-canisters-and-controllers","title":{"rendered":"Can Restek repair canisters and controllers?"},"content":{"rendered":"\n<p>Repair services are available for most of our current canister and controller products (excluding RAVEqc quick-connect air valves). Custom catalog numbers (cat.#) and details for these repairs are presented in the table below.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Equipment to Repair<\/strong><\/td><td><strong>Order cat.#<\/strong><\/td><td><strong>Service Includes<\/strong><\/td><\/tr><tr><td>Sampling kit \/ flow controller<\/td><td>550131<\/td><td>all new rubber seals in the flow controller and orifice as well as frit replacement<\/td><\/tr><tr><td>Restek canisters with RAVE valves<\/td><td>569419<\/td><td>valve replacement, leak testing, and cleaning<\/td><\/tr><tr><td>Restek canisters with Swagelok valves<\/td><td>563801<\/td><td>valve replacement, leak testing, and cleaning<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p>Reconditioning services are also available for our current generation canisters. We will replace the valve and clean and leak test the canister at a cost that is less than replacing the entire canister. To request reconditioning services, please follow these steps:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Contact Restek\u2019s customer service team or your local international representative to place an order for custom cat.# 569419 (RAVE diaphragm valve) using a purchase order.<\/li>\n\n\n\n<li>Obtain a service authorization number (SRV#) to place on the shipping container.<\/li>\n\n\n\n<li>Clean the canister before shipment to Restek.<\/li>\n\n\n\n<li>Include a completed &#8220;<a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Health-and-Safety-Declaration.pdf\">Health and Safety Declaration<\/a>.&#8221;<\/li>\n\n\n\n<li>Return the canister intact. Do not remove valves, gauges, or parts from the canister.<\/li>\n<\/ol>\n\n\n\n<p>To request any of these repair services, simply contact our&nbsp;<a href=\"https:\/\/www.restek.com\/contact-us\" target=\"_blank\" rel=\"noopener\">Customer Service Team<\/a>&nbsp;or your local&nbsp;<a href=\"https:\/\/www.restek.com\/contact-us\" target=\"_blank\" rel=\"noopener\">Restek International Representative<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Repair services are available for most of our current canister and controller products (excluding RAVEqc quick-connect air valves). Custom catalog numbers (cat.#) and details for these repairs are presented in the table below. Equipment to Repair Order cat.# Service Includes Sampling kit \/ flow controller 550131 all new rubber seals in the flow controller and&#8230;<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[23],"tags":[2677,2691],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2479,2485],"resource-technique":[],"hf_cat_post":[625],"ppma_author":[414],"class_list":["post-3489","post","type-post","status-publish","format-standard","hentry","category-faq","tag-faq-air-sampling","tag-faq-air-sampling-canisters","product-library-produkte-zur-luft-gasprobenahme","product-library-kanister-zubehor"],"acf":[],"taxonomy_info":{"category":[{"value":23,"label":"FAQ"}],"post_tag":[{"value":2677,"label":"FAQ: Air Sampling"},{"value":2691,"label":"FAQ: Air Sampling Canisters"}],"product-library":[{"value":2479,"label":"Produkte zur Luft- &amp; Gasprobenahme"},{"value":2485,"label":"Kanister &amp; Zubeh\u00f6r"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":23,"name":"FAQ","slug":"faq","term_group":0,"term_taxonomy_id":23,"taxonomy":"category","description":"","parent":0,"count":271,"filter":"raw","cat_ID":23,"category_count":271,"category_description":"","cat_name":"FAQ","category_nicename":"faq","category_parent":0}],"tag_info":[{"term_id":2677,"name":"FAQ: Air Sampling","slug":"faq-air-sampling","term_group":0,"term_taxonomy_id":2677,"taxonomy":"post_tag","description":"Browse frequently asked questions for air sampling products.","parent":0,"count":39,"filter":"raw"},{"term_id":2691,"name":"FAQ: Air Sampling Canisters","slug":"faq-air-sampling-canisters","term_group":0,"term_taxonomy_id":2691,"taxonomy":"post_tag","description":"Browse frequently asked questions for air sampling canisters.","parent":0,"count":6,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/3489","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=3489"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/3489\/revisions"}],"predecessor-version":[{"id":72204,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/3489\/revisions\/72204"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=3489"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=3489"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=3489"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=3489"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=3489"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=3489"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=3489"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=3489"},{"taxonomy":"hf_cat_post","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/hf_cat_post?post=3489"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=3489"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}