{"id":42384,"date":"2019-09-19T04:00:00","date_gmt":"2019-09-19T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/comprendre-la-separation-en-mode-hilic\/"},"modified":"2026-01-28T19:22:45","modified_gmt":"2026-01-28T19:22:45","slug":"comprendre-la-separation-en-mode-hilic","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/videos-fr\/gnav3663-fr\/comprendre-la-separation-en-mode-hilic","title":{"rendered":"Comprendre la s\u00e9paration en mode HILIC"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Understanding the HILIC Separation Method in LC\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/f83U3zgWbPY?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Description<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">(sous-titres disponibles en fran\u00e7ais)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La chromatographie liquide d\u2019interaction hydrophile, ou HILIC, est un mode de chromatographie liquide (LC) servant \u00e0 s\u00e9parer des analytes polaires en utilisant des phases stationnaires polaires (elles aussi) et des conditions initiales de phases mobiles \u00e0 fort pourcentage de solvant organique. Rejoignez-nous pour explorer les s\u00e9parations en mode HILIC.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Ressources compl\u00e9mentaires<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/articles\/how-to-avoid-common-problems-with-hilic-methods\/\" target=\"_blank\" rel=\"noreferrer noopener\">Comment \u00e9viter les probl\u00e8mes courants avec les m\u00e9thodes HILIC ?<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/articles\/raptor-hilic-si-simplify-the-switch-to-hilic\" target=\"_blank\" rel=\"noreferrer noopener\">Simplifiez le passage en mode HILIC avec les colonnes Raptor HILIC-Si<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Produits associ\u00e9s Restek<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/p\/9310A5E\" target=\"_blank\" rel=\"noreferrer noopener\">Colonnes Raptor HILIC-Si<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transcription<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Dans cette s\u00e9rie de \u201cconseils Restek\u201d, nous allons aborder la question du d\u00e9veloppement de m\u00e9thodes HILIC.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Int\u00e9ressons-nous tout d\u2019abord aux m\u00e9canismes de s\u00e9paration du mode HILIC. C\u2019est un mode de s\u00e9paration utilisant des phases stationnaires polaires. Comme la phase stationnaire est polaire, le mode HILIC est tout \u00e0 fait adapt\u00e9 \u00e0 l\u2019analyse des mol\u00e9cules polaires qui sont peu retenues en phase inverse.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les phases mobiles sont les m\u00eames que celles utilis\u00e9es en phase inverse. Cependant, dans les s\u00e9parations HILIC, les conditions initiales de phase mobile contiennent un fort pourcentage d\u2019organique pour cr\u00e9er une couche riche en eau \u00e0 la surface de la phase stationnaire polaire.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Comme les analytes polaires sont solubles dans cette couche aqueuse, ils peuvent interagir avec la phase stationnaire polaire et \u00eatre retenus gr\u00e2ce \u00e0 diff\u00e9rents m\u00e9canismes, dont les liaisons hydrog\u00e8ne, les interactions dip\u00f4le-dip\u00f4le et l\u2019\u00e9change ionique. Avec une r\u00e9partition\/distribution entre les phases stationnaires, la couche aqueuse et les phases mobiles, le m\u00e9lange de compos\u00e9s polaires peut \u00eatre \u00e9lu\u00e9 de mani\u00e8re s\u00e9lective sur la colonne HILIC.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Comme la phase mobile contient un fort pourcentage de solvant organique, la sensibilit\u00e9 est significativement augment\u00e9e en d\u00e9tection MS.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Donc, si vous souhaitez essayer ce mode HILIC, nous vous donnerons dans de prochaines vid\u00e9os des conseils qui vous aideront \u00e0 d\u00e9velopper vos propres m\u00e9thodes HILIC.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si vous appr\u00e9ciez ces vid\u00e9os, s\u2019il vous pla\u00eet, \u201clikez\u201d, partagez et inscrivez-vous. Vous pouvez proposer des id\u00e9es pour un futur conseil technique dans les commentaires ci-dessous. Merci d\u2019avoir regard\u00e9 cette vid\u00e9o et \u00e0 bient\u00f4t.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Cette astuce Restek est la premi\u00e8re partie d&#8217;une s\u00e9rie de vid\u00e9os vous permettant de comprendre et d&#8217;optimiser les s\u00e9parations en mode HILIC.<\/p>\n","protected":false},"author":11,"featured_media":41312,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[771],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2463,2445],"resource-technique":[2318,2354],"ppma_author":[414],"class_list":["post-42384","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-fr","product-library-colonnes-lc","product-library-produits-pour-la-chromatographie-en-phase-liquide","resource-technique-chromatographie-en-phase-liquide","resource-technique-hilic-fr"],"acf":[],"taxonomy_info":{"category":[{"value":771,"label":"Vid\u00e9os"}],"product-library":[{"value":2463,"label":"Colonnes LC"},{"value":2445,"label":"Produits pour la chromatographie en phase liquide"}],"resource-technique":[{"value":2318,"label":"Chromatographie en phase liquide"},{"value":2354,"label":"HILIC"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3663-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":771,"name":"Vid\u00e9os","slug":"videos-fr","term_group":0,"term_taxonomy_id":771,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":771,"category_count":138,"category_description":"","cat_name":"Vid\u00e9os","category_nicename":"videos-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/42384","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=42384"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/42384\/revisions"}],"predecessor-version":[{"id":85667,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/42384\/revisions\/85667"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/41312"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=42384"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=42384"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=42384"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=42384"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=42384"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=42384"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=42384"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=42384"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=42384"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}