{"id":42434,"date":"2019-10-01T04:00:00","date_gmt":"2019-10-01T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/comment-conditionner-votre-colonne-et-systeme-lc-pour-le-mode-hilic\/"},"modified":"2026-01-28T14:45:14","modified_gmt":"2026-01-28T14:45:14","slug":"comment-conditionner-votre-colonne-et-systeme-lc-pour-le-mode-hilic","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/videos-fr\/gnav3575-fr\/comment-conditionner-votre-colonne-et-systeme-lc-pour-le-mode-hilic","title":{"rendered":"Comment conditionner votre colonne et syst\u00e8me LC pour le mode HILIC ?"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Conditioning Your LC Instrument and Column for HILIC\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/znIAVFtVjOI?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Description&nbsp;<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Sous-titres disponibles en fran\u00e7ais.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La chromatographie liquide d\u2019interaction hydrophile, ou HILIC, est un mode de chromatographie liquide (LC) servant \u00e0 s\u00e9parer des analytes polaires en utilisant des phases stationnaires polaires et des conditions initiales de phases mobiles \u00e0 tr\u00e8s fort pourcentage de solvant organique. De par ces conditions initiales fortement organiques, il est donc important de bien conditionner votre syst\u00e8me et votre colonne afin d\u2019obtenir les meilleures performances chromatographiques. Nous allons discuter de ces conditionnements dans cette vid\u00e9o.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Ressources compl\u00e9mentaires<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/articles\/gnar2716\/how-to-avoid-common-problems-with-hilic-methods\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/fr\/articles-fr\/gnar2716\/how-to-avoid-common-problems-with-hilic-methods\/\" rel=\"noreferrer noopener\">Comment \u00e9viter les probl\u00e8mes courants avec les m\u00e9thodes HILIC ?<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/articles\/gnss2687\/raptor-hilic-si-simplify-the-switch-to-hilic\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/fr\/articles-fr\/gnss2687\/raptor-hilic-si-simplify-the-switch-to-hilic\/\" rel=\"noreferrer noopener\">Simplifiez le passage en mode HILIC avec les colonnes Raptor HILIC-Si<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Produits associ\u00e9s Restek<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/c\/1793\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/c\/1793\" rel=\"noreferrer noopener\">Colonnes Raptor HILIC-Si<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transcription<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Vous avez une nouvelle colonne HILIC et souhaitez d\u00e9velopper une m\u00e9thode d\u2019analyse avec ce mode.&nbsp;<br>Par quoi commencer ?&nbsp;&nbsp;<br>Comme nous en avons discut\u00e9 au pr\u00e9alable, pour les s\u00e9parations HILIC,&nbsp;on utilise des conditions initiales \u00e0 fort pourcentage d\u2019organique&nbsp;pour cr\u00e9er une couche riche en eau \u00e0 la surface de la phase stationnaire polaire.&nbsp;Il est donc n\u00e9cessaire de conditionner puis d\u2019\u00e9quilibrer la colonne entre chaque analyse&nbsp;pour r\u00e9tablir la couche aqueuse \u00e0 la surface des particules.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Quand vous commencez \u00e0 utiliser une nouvelle colonne HILIC ou quand vous changez la composition des phases mobiles,&nbsp;nous vous recommandons de rincer la colonne avec au moins 50 volumes de colonne de phase mobile.&nbsp;De plus, au moins 10 injections de blanc,&nbsp;dans les conditions d\u2019analyse, doivent \u00eatre effectu\u00e9es lorsque vous d\u00e9marrez une nouvelle s\u00e9quence d\u2019analyses.&nbsp;Le temps d\u2019\u00e9quilibration entre chaque injection&nbsp;est tr\u00e8s d\u00e9pendant de l\u2019analyte, donc assurez-vous de bien observer la reproductibilit\u00e9 des temps de r\u00e9tention&nbsp;pour d\u00e9terminer le temps n\u00e9cessaire \u00e0 la&nbsp;r\u00e9-\u00e9quilibration.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Maintenant, en plus de la colonne,&nbsp;nous tenons \u00e0 vous rappeler que&nbsp;votre syst\u00e8me LC doit \u00e9galement \u00eatre conditionn\u00e9 pour les analyses en mode HILIC.&nbsp;Nous savons qu\u2019une grande majorit\u00e9 des syst\u00e8mes LC sont utilis\u00e9s en phase inverse.&nbsp;Donc avant de passer \u00e0 des analyses HILIC,&nbsp;assurez-vous de rincer le syst\u00e8me avec une phase mobile fortement organique&nbsp;sur une p\u00e9riode de 30 \u00e0 60 minutes.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Maintenant que vous avez conditionn\u00e9 votre colonne et votre syst\u00e8me pour les analyses HILIC,&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vous \u00eates pr\u00eats !&nbsp;<br>Si vous appr\u00e9ciez ces vid\u00e9os, vous pouvez&nbsp;\u00ab&nbsp;liker&nbsp;\u00bb, partager&nbsp;et&nbsp;vous abonner.&nbsp;<br>Vous pouvez&nbsp;proposer&nbsp;des id\u00e9es pour un futur conseil technique dans les commentaires ci-dessous.&nbsp;<br>Merci d\u2019avoir regard\u00e9 cette vid\u00e9o et \u00e0 bient\u00f4t.&nbsp;<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Dans cette vid\u00e9o, nous parlerons du bon conditionnement de votre colonne et de votre syst\u00e8me pour travailler en mode HILIC.<\/p>\n","protected":false},"author":11,"featured_media":41024,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[771],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2463,2445],"resource-technique":[2318,2354],"ppma_author":[414],"class_list":["post-42434","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-fr","product-library-colonnes-lc","product-library-produits-pour-la-chromatographie-en-phase-liquide","resource-technique-chromatographie-en-phase-liquide","resource-technique-hilic-fr"],"acf":[],"taxonomy_info":{"category":[{"value":771,"label":"Vid\u00e9os"}],"product-library":[{"value":2463,"label":"Colonnes LC"},{"value":2445,"label":"Produits pour la chromatographie en phase liquide"}],"resource-technique":[{"value":2318,"label":"Chromatographie en phase liquide"},{"value":2354,"label":"HILIC"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3575-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":771,"name":"Vid\u00e9os","slug":"videos-fr","term_group":0,"term_taxonomy_id":771,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":771,"category_count":138,"category_description":"","cat_name":"Vid\u00e9os","category_nicename":"videos-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/42434","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=42434"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/42434\/revisions"}],"predecessor-version":[{"id":85177,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/42434\/revisions\/85177"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/41024"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=42434"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=42434"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=42434"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=42434"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=42434"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=42434"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=42434"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=42434"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=42434"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}