{"id":42487,"date":"2018-01-03T05:00:00","date_gmt":"2018-01-03T05:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/troubleshooting-lc-trainees-de-pic-en-hplc-comment-y-remedier\/"},"modified":"2026-01-28T21:52:48","modified_gmt":"2026-01-28T21:52:48","slug":"troubleshooting-lc-trainees-de-pic-en-hplc-comment-y-remedier","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/videos-fr\/gnav3619-fr\/troubleshooting-lc-trainees-de-pic-en-hplc-comment-y-remedier","title":{"rendered":"Troubleshooting LC \u2013 Tra\u00een\u00e9es de pic en HPLC : comment y rem\u00e9dier ?"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"LC Troubleshooting\u2014All of My Peaks are Tailing! What Should I Do?\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/2eRLoGeYvjo?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Description<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">(sous-titres disponibles en fran\u00e7ais)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les interactions des compos\u00e9s d\u2019int\u00e9r\u00eats avec les sites silanols de la colonne sont souvent la cause des tra\u00een\u00e9es de pics observ\u00e9es en chromatographie en phase liquide (LC).&nbsp;&nbsp;&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Retrouvez dans cette vid\u00e9o nos solutions pour r\u00e9duire ou supprimer les tra\u00een\u00e9es de pics ind\u00e9sirables.&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Ressources compl\u00e9mentaires<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/fr\/videos-fr\/gnav3619-fr\/gnav3619\/troubleshooting-lc-trainees-de-pic-en-hplc-comment-y-remedier\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/GNAV3619\/lc-troubleshooting-all-of-my-peaks-are-tailing-what-should-i-do\/\" rel=\"noreferrer noopener\">Tra\u00een\u00e9es&nbsp;de pic en&nbsp;HPLC :&nbsp;comment y&nbsp;rem\u00e9dier ?<\/a><\/li>\n\n\n\n<li>Troubleshooting HPLC \u2013 Tra\u00een\u00e9es de Pic<\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/blogs\/gnbl4865\/when-should-you-use-a-buffer-for-hplc-how-does-it-work-and-which-one-to-use\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/GNBL4865\/when-should-you-use-a-buffer-for-hplc-how-does-it-work-and-which-one-to-use\/\" rel=\"noreferrer noopener\">Quand utiliser un tampon en HPLC ?<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Produits associ\u00e9s Restek<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/c\/1123?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noreferrer noopener\">Accessoires de phase mobile<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transcription<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Merci de nous rejoindre pour un nouveau \u201cconseil Restek\u201d. Nous allons aborder le probl\u00e8me des tra\u00een\u00e9es de pics lors des analyses par LC et proposer des solutions pour surmonter cette difficult\u00e9. Nous savons tous que les train\u00e9es de pics peuvent avoir diff\u00e9rentes origines, notamment les interactions secondaires avec les silanols, la contamination, la surcharge de la colonne\u2026 la liste est longue. Int\u00e9ressons-nous aux interactions secondaires avec les silanols, et aux moyens de les att\u00e9nuer pendant la phase de d\u00e9veloppement. Lorsque je commence \u00e0 examiner les train\u00e9es de pics et \u00e0 chercher ce qui pourrait aider \u00e0 les r\u00e9duire, je commence par observer toutes les conditions analytiques que j\u2019ai mises en place dans ma m\u00e9thode. &nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Une fois pass\u00e9es en revue les phases mobiles que j\u2019ai choisies, le gradient, les temp\u00e9ratures, etc., je m\u2019attarde un peu plus sur la structure des analytes. Si je regarde les analytes, la charge positive des compos\u00e9s, concr\u00e8tement, tout ce qui peut contenir une fonction amine, comme un m\u00e9dicament faiblement basique, peut interagir avec la charge n\u00e9gative des silanols r\u00e9siduels pr\u00e9sents \u00e0 la surface de la silice. &nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">C\u2019est cette interaction qui cr\u00e9e les train\u00e9es de pics. Une fa\u00e7on simple de contourner ce probl\u00e8me est d\u2019ajouter un tampon dans vos phases mobiles. Lors des analyses LC-MS habituelles, nous ajoutons d\u00e9j\u00e0 un acide aux \u00e9luants aqueux et organiques de nos phases mobiles. L\u2019ajout de sels compl\u00e9mentaires, comme le formiate d\u2019ammonium dans l\u2019acide formique, peut vraiment aider \u00e0 r\u00e9duire certaines de ces interactions avec les silanols. &nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En effet, la charge positive du sel tampon que nous ajoutons peut interagir avec la charge n\u00e9gative des silanols \u00e0 la surface de la silice et cr\u00e9er cette interaction. Elle va emp\u00eacher votre analyte d\u2019interagir avec la surface de la silice. Le m\u00e9canisme de r\u00e9tention primaire est provoqu\u00e9 par la phase stationnaire que vous avez choisie. Il ne faut pas oublier d\u2019ajouter les tampons \u00e0 la fois dans les \u00e9luants aqueux et organiques pendant les analyses en mode gradient, afin d\u2019att\u00e9nuer les tra\u00een\u00e9es \u00e0 la fois sur les pics \u00e0 \u00e9lution pr\u00e9coce et tardive. &nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La prochaine fois que vous avez des train\u00e9es de pics pendant l\u2019analyse de petits m\u00e9dicaments basiques, essayez d\u2019ajouter un tampon \u00e0 la phase mobile pour vous en d\u00e9barrasser.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nous vous remercions d\u2019avoir visionn\u00e9 ce \u201cconseil Restek\u201d.&nbsp;<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Les tra\u00een\u00e9es de pics observ\u00e9es en chromatographie en phase liquide (LC) sont un probl\u00e8me fr\u00e9quent. Regardez cette astuce Restek&#8221; pour r\u00e9soudre ce probl\u00e8me.&#8221;<\/p>\n","protected":false},"author":11,"featured_media":41162,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[771],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2463,2445],"resource-technique":[2318],"ppma_author":[414],"class_list":["post-42487","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-fr","product-library-colonnes-lc","product-library-produits-pour-la-chromatographie-en-phase-liquide","resource-technique-chromatographie-en-phase-liquide"],"acf":[],"taxonomy_info":{"category":[{"value":771,"label":"Vid\u00e9os"}],"product-library":[{"value":2463,"label":"Colonnes LC"},{"value":2445,"label":"Produits pour la chromatographie en phase liquide"}],"resource-technique":[{"value":2318,"label":"Chromatographie en phase liquide"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3619-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":771,"name":"Vid\u00e9os","slug":"videos-fr","term_group":0,"term_taxonomy_id":771,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":771,"category_count":138,"category_description":"","cat_name":"Vid\u00e9os","category_nicename":"videos-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/42487","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=42487"}],"version-history":[{"count":8,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/42487\/revisions"}],"predecessor-version":[{"id":85736,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/42487\/revisions\/85736"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/41162"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=42487"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=42487"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=42487"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=42487"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=42487"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=42487"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=42487"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=42487"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=42487"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}