{"id":42533,"date":"2019-11-26T05:00:00","date_gmt":"2019-11-26T05:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/utiliser-une-fibre-spme-arrow\/"},"modified":"2025-12-16T14:27:03","modified_gmt":"2025-12-16T14:27:03","slug":"utiliser-une-fibre-spme-arrow","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/videos-fr\/gnav3659-fr\/utiliser-une-fibre-spme-arrow","title":{"rendered":"Utiliser une fibre SPME Arrow"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"SPME Arrow Tips\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/wASzuLOd9H8?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Description<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">(sous-titres disponibles en fran\u00e7ais)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Que vous pratiquiez des analyses alimentaires, environnementales ou cliniques, les fibres SPME Arrow Restek sont un outil indispensable. Cette technologie de pr\u00e9paration d\u2019\u00e9chantillons, rapide et automatis\u00e9e, permet de r\u00e9duire la manipulation des \u00e9chantillons, le temps d\u2019extraction et la consommation de solvants.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dans cette vid\u00e9o, nous vous montrons comment utiliser une fibre SPME Arrow. Il est important de suivre la proc\u00e9dure \u00e0 la lettre : voici quelques conseils pour la r\u00e9ussir \u00e0 chaque fois.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Ressources compl\u00e9mentaires<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/chromablography\/spme-arrow-for-acrylamide-in-potato-chips\" target=\"_blank\" rel=\"noreferrer noopener\">SPME Arrow for Acrylamide in Potato Chips<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/chromablography\/spme-arrow-sensitivity--speed\" target=\"_blank\" rel=\"noreferrer noopener\">SPME Arrow Sensitivity = Speed<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Produits associ\u00e9s Restek<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/c\/1354?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noreferrer noopener\">Fibres SPME Arrow Restek pour syst\u00e8mes PAL 3<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1643?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noreferrer noopener\">Accessoires pour les fibres SPME Arrow<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transcription<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bonjour ! Aujourd\u2019hui, nous allons vous montrer comment utiliser le support d\u2019injection manuel SPME Arrow Restek. Il est important de suivre cette proc\u00e9dure correctement, et nous avons quelques astuces \u00e0 vous montrer pour la r\u00e9ussir syst\u00e9matiquement.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Commen\u00e7ons. En ins\u00e9rant le support d\u2019injection SPME Arrow dans un flacon ou un port d\u2019injection, il est important de maintenir la pression vers le haut sur la partie sup\u00e9rieure du support. Cela permettra de garder la fibre Arrow dans la gaine, et de ne pas l\u2019ab\u00eemer au moment o\u00f9 elle perce le flacon ou le septum. Pour maintenir la pression vers le haut facilement, placez votre pouce ou un doigt sur l\u2019attache, comme ceci.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En per\u00e7ant le flacon, continuez de faire pression vers le haut sur la partie sup\u00e9rieure du support jusqu\u2019\u00e0 insertion compl\u00e8te. Vous pouvez alors lib\u00e9rer la fibre Arrow. D\u00e9placez votre main sur l\u2019outil avec pr\u00e9caution afin d\u2019utiliser votre pouce ou un doigt pour faire descendre la partie sup\u00e9rieure de l\u2019outil.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Faites pression jusqu\u2019\u00e0 ce que la fibre soit totalement lib\u00e9r\u00e9e. Une fois l\u2019extraction termin\u00e9e selon votre m\u00e9thode d\u2019\u00e9chantillonnage, vous pouvez retirer la fibre. Naturellement, vous allez vouloir retirer l\u2019outil du flacon directement, mais vous risquez d\u2019endommager le rev\u00eatement de la fibre. Il faut simplement positionner votre pouce ou un doigt sous l\u2019attache, et pousser vers le haut pour r\u00e9tracter la fibre. Ainsi, avec un mouvement souple et lent vers le haut, vous pouvez retirer l\u2019outil du flacon en toute s\u00e9curit\u00e9, en prenant soin de maintenir la pression vers le haut.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Attention \u00e0 ne jamais inverser les \u00e9tapes. N\u2019appuyez jamais sur l\u2019attache en ins\u00e9rant l\u2019outil dans un flacon, cela risquerait d\u2019endommager le rev\u00eatement du septum et d\u2019ab\u00eemer la fibre Arrow. De la m\u00eame mani\u00e8re, n\u2019appuyez jamais sur l\u2019attache en enlevant la fibre Arrow du flacon. Cela risque \u00e9galement d\u2019endommager la fibre Arrow. Et c\u2019est tout ! Le support d\u2019injection SPME Arrow Restek est aussi facile que cela \u00e0 utiliser.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vous pouvez \u201cliker\u201d cette vid\u00e9o et vous abonner et nous vous remercions d\u2019avoir regard\u00e9 cette \u201castuce Restek\u201d.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Utilisez-vous des fibres SPME Arrow ? Vous vous demandez comment les utiliser ? Regardez notre conseil Restek pour apprendre quelques astuces qui vous permettront d&#8217;utiliser correctement cet outil indispensable !<\/p>\n","protected":false},"author":11,"featured_media":41288,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[771],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-42533","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-fr"],"acf":[],"taxonomy_info":{"category":[{"value":771,"label":"Vid\u00e9os"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3659-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":771,"name":"Vid\u00e9os","slug":"videos-fr","term_group":0,"term_taxonomy_id":771,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":771,"category_count":138,"category_description":"","cat_name":"Vid\u00e9os","category_nicename":"videos-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/42533","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=42533"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/42533\/revisions"}],"predecessor-version":[{"id":74715,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/42533\/revisions\/74715"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/41288"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=42533"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=42533"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=42533"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=42533"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=42533"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=42533"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=42533"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=42533"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=42533"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}