{"id":42539,"date":"2018-01-03T05:00:00","date_gmt":"2018-01-03T05:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/using-your-exp-lc-guard-column-protection-system\/"},"modified":"2026-10-01T19:53:07","modified_gmt":"2026-10-01T19:53:07","slug":"using-your-exp-lc-guard-column-protection-system","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/videos\/gnav3664\/using-your-exp-lc-guard-column-protection-system","title":{"rendered":"Using Your EXP LC Guard Column Protection System"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Using Your EXP LC Guard Column Protection System\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/nJgZ1pkYllA?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Description<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The EXP LC Guard Column Protection System is&nbsp;an easy to use and versatile guard cartridge holder that is&nbsp;appropriate for use with Restek Force and Raptor LC column lines.&nbsp;It has a unique design hold the guard cartridges in a specific configuration, so you can never put it together incorrectly. It also&nbsp;has a quick-change feature to make it easy to replace cartridges.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Additional Resources<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/content.restek.com\/content\/published\/api\/v1.1\/assets\/CONTF4B8244D784B4A8A95F7A4CF1157F7AD\/native\/GNSS1774C-UNV.pdf?channelToken=6428daeb0e4e4341beecd8e2b41b4d46&amp;download=false\" target=\"_blank\" rel=\"noreferrer noopener\">E<\/a><a href=\"https:\/\/discover.restek.com\/en\/articles\/gnss1774\/exp-and-exp2-fittings-reusable-fittings-for-easy-reliable-hplc-uhplc-connections\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/en\/articles\/gnss1774\/exp-and-exp2-fittings-reusable-fittings-for-easy-reliable-hplc-uhplc-connections\">XP and EXP2 Fittings<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Restek Recommended Tools &amp; Parts<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/p\/25808\" target=\"_blank\" rel=\"noopener\">EXP Direct Connect Holder<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1821\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/c\/1821\" rel=\"noreferrer noopener\">Raptor EXP Guard Column Cartridges<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1822\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/c\/1822\" rel=\"noreferrer noopener\">Force EXP Guard Column Cartridges<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transcript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hi everyone, thanks for joining us for this Restek tip. Our topic today is the EXP guard column system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This type of guard cartridge and holder is meant for our Force and our Raptor columns, and it&#8217;s really important that you match the phase of the guard to the phase of the analytical column. So, C18 goes with C18, Biphenyl goes with Biphenyl, and so on. The cartridges used are&nbsp;5-millimeter packed bed, and the nice thing about it is they only fit into the holder one way. So, if you&#8217;ve never used them before, or if you feel like you&#8217;re a klutz in the lab, there&#8217;s really no way to screw it up. The holder itself is auto-adjustable, so it can be used with any type of column. It has a reusable ferrule with a PEEK side that fits into the port, and a metal side that faces the nut to securely grip the tubing for tightening.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Now, when it comes time to make all these connections for the line that comes from the autosampler to the guard column inlet, you want to have a wrench-tight seal up to 20,000&nbsp;psi. On the column side, you have a couple of options. You can use a hand-tight to about 9000 psi, or&nbsp;for UHPLC system, you&#8217;d want to go with a wrench-tight connection, which is a quarter to a half turn past hand-tight, and that will seal up to 20,000&nbsp;psi. Now, the coolest thing about this EXP holder is that when it comes time to change the guard cartridge, all you have to do is open the holder, remove the old cartridge, insert the new one, and hand-tight to connect it back together. That&#8217;s really all there is, so it makes this routine maintenance very easy.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Thanks for joining us, and stay tuned for more tech tips from your friends at Restek.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Protect your high-performance Raptor and Force LC columns with the EXP LC column protection system. See how easy they are to use in this Restek Tip.<\/p>\n","protected":false},"author":11,"featured_media":41316,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[8],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-42539","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos"],"acf":[],"taxonomy_info":{"category":[{"value":8,"label":"Videos"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3664-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"Videos","slug":"videos","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":139,"filter":"raw","cat_ID":8,"category_count":139,"category_description":"","cat_name":"Videos","category_nicename":"videos","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/42539","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=42539"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/42539\/revisions"}],"predecessor-version":[{"id":85007,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/42539\/revisions\/85007"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/41316"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=42539"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=42539"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=42539"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=42539"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=42539"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=42539"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=42539"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=42539"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=42539"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}