{"id":42581,"date":"2019-10-29T04:00:00","date_gmt":"2019-10-29T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/comment-bien-choisir-son-tampon-en-mode-hilic\/"},"modified":"2026-01-27T23:38:41","modified_gmt":"2026-01-27T23:38:41","slug":"comment-bien-choisir-son-tampon-en-mode-hilic","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/videos-fr\/gnav4887-fr\/comment-bien-choisir-son-tampon-en-mode-hilic","title":{"rendered":"Comment bien choisir son tampon en mode HILIC ?"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Buffer Choices for HILIC\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/O0WWmQmhzpk?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Description&nbsp;<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">(Sous-titres disponibles en fran\u00e7ais)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La chromatographie liquide d\u2019interaction hydrophile, ou HILIC, est un mode de chromatographie liquide (LC) servant \u00e0 s\u00e9parer des analytes polaires en utilisant des phases stationnaires polaires (elles aussi) et des conditions initiales de phases mobiles \u00e0 fort pourcentage de solvant organique. Les tampons sont tr\u00e8s importants en mode HILIC car les \u00e9tats d\u2019ionisation des analytes ET des phases stationnaires vont impacter la s\u00e9paration. Nous vous expliquons ici comment optimiser les concentrations de ces tampons.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Ressources compl\u00e9mentaires<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/articles\/gnar2716\/how-to-avoid-common-problems-with-hilic-methods\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/fr\/articles-fr\/gnar2716\/how-to-avoid-common-problems-with-hilic-methods\/\" rel=\"noreferrer noopener\">Comment \u00e9viter les probl\u00e8mes courants avec les m\u00e9thodes HILIC ?<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/articles\/gnss2687\/raptor-hilic-si-simplify-the-switch-to-hilic\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/fr\/articles-fr\/gnss2687\/raptor-hilic-si-simplify-the-switch-to-hilic\/\" rel=\"noreferrer noopener\">Simplifiez le passage en mode HILIC avec les colonnes Raptor HILIC-Si<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Produits associ\u00e9s Restek<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/c\/1793\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/c\/1793\" rel=\"noreferrer noopener\">Colonnes Raptor HILIC-Si<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Transcription<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Quand vous commencez votre d\u00e9veloppement de m\u00e9thode HILIC,&nbsp;vous devez choisir les phases mobiles appropri\u00e9es. Une bonne s\u00e9paration en mode HILIC d\u00e9pend des \u00e9tats d\u2019ionisation de la phase stationnaire ET des&nbsp;analytes, qui sont contr\u00f4l\u00e9s par le pH des phases mobiles.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour commencer, nous recommandons de pr\u00e9parer au moins 3 phases mobiles aqueuses \u00e0 diff\u00e9rents pH. La premi\u00e8re est du formiate d\u2019ammonium 10mM ajust\u00e9e \u00e0 pH 3 avec une solution d\u2019acide formique. La seconde est de l\u2019ac\u00e9tate d\u2019ammonium 10mM ajust\u00e9e \u00e0 pH 5 avec une solution d\u2019acide ac\u00e9tique, et la troisi\u00e8me est de l\u2019ac\u00e9tate d\u2019ammonium 10mM ajust\u00e9e \u00e0 pH 6.8 avec une solution d\u2019acide ac\u00e9tique.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En travaillant en&nbsp;isocratique&nbsp;ou en gradient avec des conditions initiales \u00e0 90 \u2013 95% d\u2019ac\u00e9tonitrile,&nbsp;vous devriez savoir quel pH est le plus appropri\u00e9 simplement en regardant les formes\/sym\u00e9tries des pics. Une fois le pH de la phase mobile d\u00e9termin\u00e9, vous pouvez ensuite optimiser la m\u00e9thode en ajustant la concentration du tampon et des conditions d\u2019\u00e9lution. Parfois, vous constaterez qu\u2019une concentration de tampon plus \u00e9lev\u00e9e peut donner de meilleures formes\/sym\u00e9tries de pics. Mais gardez bien en t\u00eate que le sel contenu dans le tampon peut pr\u00e9cipiter en pr\u00e9sence d\u2019une forte teneur en solvant organique. Enfin, pour les \u00e9lutions de gradient, une bonne pratique consiste \u00e0 tamponner la phase mobile aqueuse ET la phase mobile organique pour garder une force ionique constante durant le temps de l\u2019analyse. Si vous prenez soin de bien s\u00e9lectionner le pH et la concentration du tampon de vos phases mobiles,&nbsp;vous commencez alors dans les meilleures conditions.&nbsp;&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Si vous appr\u00e9ciez ces vid\u00e9os, vous pouvez \u201cliker\u201d,&nbsp;partager et vous abonner.&nbsp;<br>Vous pouvez proposer des id\u00e9es pour un futur conseil technique dans les commentaires ci-dessous.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Merci d\u2019avoir regard\u00e9 cette vid\u00e9o et \u00e0 bient\u00f4t.&nbsp;<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Nous vous expliquons ici comment optimiser les concentrations des tampons en mode HILIC.<\/p>\n","protected":false},"author":11,"featured_media":41432,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[771],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2466,2445],"resource-technique":[2318,2354],"ppma_author":[414],"class_list":["post-42581","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-fr","product-library-gestion-de-la-phase-mobile","product-library-produits-pour-la-chromatographie-en-phase-liquide","resource-technique-chromatographie-en-phase-liquide","resource-technique-hilic-fr"],"acf":[],"taxonomy_info":{"category":[{"value":771,"label":"Vid\u00e9os"}],"product-library":[{"value":2466,"label":"Gestion de la phase mobile"},{"value":2445,"label":"Produits pour la chromatographie en phase liquide"}],"resource-technique":[{"value":2318,"label":"Chromatographie en phase liquide"},{"value":2354,"label":"HILIC"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV4887-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":771,"name":"Vid\u00e9os","slug":"videos-fr","term_group":0,"term_taxonomy_id":771,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":771,"category_count":138,"category_description":"","cat_name":"Vid\u00e9os","category_nicename":"videos-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/42581","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=42581"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/42581\/revisions"}],"predecessor-version":[{"id":85021,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/42581\/revisions\/85021"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/41432"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=42581"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=42581"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=42581"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=42581"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=42581"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=42581"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=42581"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=42581"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=42581"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}