{"id":43378,"date":"2020-10-12T00:00:00","date_gmt":"2020-10-12T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/ameliorez-vos-screenings-toxicologiques-a-laide-des-colonnes-lc-raptor-biphenyl\/"},"modified":"2026-10-02T13:27:25","modified_gmt":"2026-10-02T13:27:25","slug":"ameliorez-vos-screenings-toxicologiques-a-laide-des-colonnes-lc-raptor-biphenyl","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/articles-fr\/cfss2310-fr\/ameliorez-vos-screenings-toxicologiques-a-laide-des-colonnes-lc-raptor-biphenyl","title":{"rendered":"Am\u00e9liorez vos Screenings Toxicologiques \u00e0 l\u2019aide des Colonnes LC Raptor Biphenyl"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>231 compos\u00e9s dont plus de 40 isobares, 10 familles de m\u00e9dicaments et 22 compos\u00e9s en ESI-, en moins de 10 minutes.<\/li>\n\n\n\n<li>La particule SPP Raptor combin\u00e9e \u00e0 la s\u00e9lectivit\u00e9 \u00e9prouv\u00e9e de la chimie Biphenyl de Restek vous offre la colonne LC la plus polyvalente du march\u00e9.<\/li>\n\n\n\n<li>Obtenez une excellente s\u00e9paration des isobares critiques, sans tra\u00een\u00e9es de pics.<\/li>\n\n\n\n<li>Obtenez des m\u00e9thodes LC-MS\/MS rapides et fiables, \u00e0 haute cadence d\u2019analyses et avec des phases mobiles simples, tout en ayant une sensibilit\u00e9 accrue.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">La prise de m\u00e9dicaments anti-douleur est en constante augmentation. En cons\u00e9quence, les h\u00f4pitaux et laboratoires de r\u00e9f\u00e9rence constatent une augmentation du nombre d\u2019\u00e9chantillons de patient qui doivent \u00eatre test\u00e9s pour rechercher ces m\u00e9dicaments anti-douleur afin de pr\u00e9venir tout abus et d\u2019assurer la s\u00e9curit\u00e9 des patients ainsi que le respect de leur traitement m\u00e9dicamenteux. Le suivi th\u00e9rapeutique peut \u00eatre difficile en raison de faibles concentrations, d\u2019interf\u00e9rences potentielles provenant de la matrice et de la pr\u00e9sence de compos\u00e9s isobares. Pour relever ces d\u00e9fis, de nombreux laboratoires analysant ces m\u00e9dicaments se tournent vers la chromatographie liquide coupl\u00e9e \u00e0 la spectrom\u00e9trie de masse (LC-MS\/MS) pour sa vitesse, sa sensibilit\u00e9 et sa sp\u00e9cificit\u00e9 accrues.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Comme le montre l\u2019analyse ci-dessous, la colonne Restek Raptor Biphenyl est id\u00e9ale pour le d\u00e9veloppement de m\u00e9thodes de screening toxicologique rapides et efficaces. Gr\u00e2ce \u00e0 sa r\u00e9tention tr\u00e8s \u00e9lev\u00e9e et sa s\u00e9lectivit\u00e9 unique, 231 compos\u00e9s et m\u00e9tabolites \u2013 dont plus de 40 isobares \u2013 de diff\u00e9rentes familles peuvent \u00eatre analys\u00e9s en seulement 10 minutes. De plus, des panels distincts ont \u00e9t\u00e9 optimis\u00e9s sur la colonne Raptor Biphenyl pour les&nbsp;<a href=\"https:\/\/www.restek.com\/global\/fr\/chromatogram-detail\/LC_CF0610\" target=\"_blank\" rel=\"noopener\">opio\u00efdes<\/a>, les&nbsp;<a href=\"https:\/\/www.restek.com\/global\/fr\/chromatogram-detail\/LC_CF0615\" target=\"_blank\" rel=\"noopener\">antianxiolytiques<\/a>, les&nbsp;<a href=\"https:\/\/www.restek.com\/global\/fr\/chromatogram-detail\/LC_CF0619\" target=\"_blank\" rel=\"noopener\">barbituriques<\/a>, les&nbsp;<a href=\"https:\/\/www.restek.com\/global\/fr\/chromatogram-detail\/LC_CF0620\" target=\"_blank\" rel=\"noopener\">AINS et analg\u00e9siques<\/a>, les&nbsp;<a href=\"https:\/\/www.restek.com\/global\/fr\/chromatogram-detail\/LC_CF0609\" target=\"_blank\" rel=\"noopener\">antid\u00e9presseurs<\/a>, les&nbsp;<a href=\"https:\/\/www.restek.com\/global\/fr\/chromatogram-detail\/LC_CF0616\" target=\"_blank\" rel=\"noopener\">anti\u00e9pileptiques<\/a>, les&nbsp;<a href=\"https:\/\/www.restek.com\/global\/fr\/chromatogram-detail\/LC_CF0608\" target=\"_blank\" rel=\"noopener\">antipsychotiques<\/a>, les&nbsp;<a href=\"https:\/\/www.restek.com\/global\/fr\/chromatogram-detail\/LC_CF0607\" target=\"_blank\" rel=\"noopener\">hallucinog\u00e8nes<\/a>&nbsp;et les&nbsp;<a href=\"https:\/\/www.restek.com\/global\/fr\/chromatogram-detail\/LC_CF0617\" target=\"_blank\" rel=\"noopener\">stimulants<\/a>&nbsp;\u00e0 utiliser pour des analyses de confirmation quantitatives.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0621.png\" alt=\"Multiclass Drug Panel on Raptor Biphenyl by LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0621<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for trans-3-Hydroxycotinine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/34834-67-8\/trans-3-Hydroxycotinine\" target=\"_blank\" rel=\"noopener\">trans-3-Hydroxycotinine<\/a><\/td><td class=\"oth\">1.32<\/td><td class=\"oth\">25<\/td><td class=\"oth\">193.1<\/td><td class=\"oth\">80.0<\/td><td class=\"oth\">134.0<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norcotinine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/17708-87-1\/Norcotinine\" target=\"_blank\" rel=\"noopener\">Norcotinine<\/a><\/td><td class=\"oth\">1.33<\/td><td class=\"oth\">25<\/td><td class=\"oth\">163.1<\/td><td class=\"oth\">80.1<\/td><td class=\"oth\">118.1<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nicotine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/54-11-5\/Nicotine\" target=\"_blank\" rel=\"noopener\">Nicotine<\/a><\/td><td class=\"oth\">1.40<\/td><td class=\"oth\">25<\/td><td class=\"oth\">163.2<\/td><td class=\"oth\">130.1<\/td><td class=\"oth\">117.1<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for BZP\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2759-28-6\/BZP\" target=\"_blank\" rel=\"noopener\">BZP<\/a><\/td><td class=\"oth\">1.47<\/td><td class=\"oth\">25<\/td><td class=\"oth\">177.2<\/td><td class=\"oth\">91.1<\/td><td class=\"oth\">65.1<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Anabasine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/40774-73-0\/Anabasine\" target=\"_blank\" rel=\"noopener\">Anabasine<\/a><\/td><td class=\"oth\">1.53<\/td><td class=\"oth\">25<\/td><td class=\"oth\">163.2<\/td><td class=\"oth\">120.1<\/td><td class=\"oth\">80.1<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Noroxymorphone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/33522-95-1\/Noroxymorphone\" target=\"_blank\" rel=\"noopener\">Noroxymorphone<\/a><\/td><td class=\"oth\">1.78<\/td><td class=\"oth\">25<\/td><td class=\"oth\">288.1<\/td><td class=\"oth\">270.1<\/td><td class=\"oth\">212.9<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Lisdexamfetamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/608137-33-3\/Lisdexamfetamine\" target=\"_blank\" rel=\"noopener\">Lisdexamfetamine<\/a><\/td><td class=\"oth\">1.79<\/td><td class=\"oth\">25<\/td><td class=\"oth\">264.2<\/td><td class=\"oth\">84.1<\/td><td class=\"oth\">91.0<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenelzine sulfate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/156-51-4\/Phenelzine sulfate\" target=\"_blank\" rel=\"noopener\">Phenelzine sulfate<\/a><\/td><td class=\"oth\">1.90<\/td><td class=\"oth\">25<\/td><td class=\"oth\">137.2<\/td><td class=\"oth\">105.1<\/td><td class=\"oth\">77.1<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetaminophen\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/103-90-2\/Acetaminophen\" target=\"_blank\" rel=\"noopener\">Acetaminophen<\/a><\/td><td class=\"oth\">1.93<\/td><td class=\"oth\">100<\/td><td class=\"oth\">152.2<\/td><td class=\"oth\">93.0<\/td><td class=\"oth\">65.0<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pregabalin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/148553-50-8\/Pregabalin\" target=\"_blank\" rel=\"noopener\">Pregabalin<\/a><\/td><td class=\"oth\">2.21<\/td><td class=\"oth\">25<\/td><td class=\"oth\">160.2<\/td><td class=\"oth\">142.1<\/td><td class=\"oth\">55.0<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cotinine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/486-56-6\/Cotinine\" target=\"_blank\" rel=\"noopener\">Cotinine<\/a><\/td><td class=\"oth\">2.27<\/td><td class=\"oth\">25<\/td><td class=\"oth\">177.2<\/td><td class=\"oth\">80.0<\/td><td class=\"oth\">98.1<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Morphine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57-27-2\/Morphine\" target=\"_blank\" rel=\"noopener\">Morphine<\/a><\/td><td class=\"oth\">2.27<\/td><td class=\"oth\">25<\/td><td class=\"oth\">286.2<\/td><td class=\"oth\">152.1<\/td><td class=\"oth\">165.0<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (+)-Ephedrine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/321-98-2\/(+)-Ephedrine\" target=\"_blank\" rel=\"noopener\">(+)-Ephedrine<\/a><\/td><td class=\"oth\">2.37<\/td><td class=\"oth\">25<\/td><td class=\"oth\">166.2<\/td><td class=\"oth\">148.1<\/td><td class=\"oth\">115.0<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Oxymorphone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-41-5\/Oxymorphone\" target=\"_blank\" rel=\"noopener\">Oxymorphone<\/a><\/td><td class=\"oth\">2.38<\/td><td class=\"oth\">25<\/td><td class=\"oth\">302.1<\/td><td class=\"oth\">227.2<\/td><td class=\"oth\">198.2<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hydromorphone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/466-99-9\/Hydromorphone\" target=\"_blank\" rel=\"noopener\">Hydromorphone<\/a><\/td><td class=\"oth\">2.61<\/td><td class=\"oth\">25<\/td><td class=\"oth\">286.2<\/td><td class=\"oth\">184.9<\/td><td class=\"oth\">156.9<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Amphetamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/300-62-9\/Amphetamine\" target=\"_blank\" rel=\"noopener\">Amphetamine<\/a><\/td><td class=\"oth\">2.63<\/td><td class=\"oth\">25<\/td><td class=\"oth\">136.2<\/td><td class=\"oth\">91.0<\/td><td class=\"oth\">65.1<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for DMAA\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/123-82-0\/DMAA\" target=\"_blank\" rel=\"noopener\">DMAA<\/a><\/td><td class=\"oth\">2.65<\/td><td class=\"oth\">25<\/td><td class=\"oth\">116.1<\/td><td class=\"oth\">57.1<\/td><td class=\"oth\">99.2<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Gabapentin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60142-96-3\/Gabapentin\" target=\"_blank\" rel=\"noopener\">Gabapentin<\/a><\/td><td class=\"oth\">2.71<\/td><td class=\"oth\">25<\/td><td class=\"oth\">172.2<\/td><td class=\"oth\">154.0<\/td><td class=\"oth\">137.1<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methylephedrine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/552-79-4\/Methylephedrine\" target=\"_blank\" rel=\"noopener\">Methylephedrine<\/a><\/td><td class=\"oth\">2.83<\/td><td class=\"oth\">25<\/td><td class=\"oth\">180.2<\/td><td class=\"oth\">162.0<\/td><td class=\"oth\">115.1<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Levetiracetam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/102767-28-2\/Levetiracetam\" target=\"_blank\" rel=\"noopener\">Levetiracetam<\/a><\/td><td class=\"oth\">2.84<\/td><td class=\"oth\">25<\/td><td class=\"oth\">171.1<\/td><td class=\"oth\">125.9<\/td><td class=\"oth\">69.2<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Desmethylolanzapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/161696-76-0\/Desmethylolanzapine\" target=\"_blank\" rel=\"noopener\">Desmethylolanzapine<\/a><\/td><td class=\"oth\">2.94<\/td><td class=\"oth\">25<\/td><td class=\"oth\">299.1<\/td><td class=\"oth\">256.1<\/td><td class=\"oth\">198.0<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norcodeine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/467-15-2\/Norcodeine\" target=\"_blank\" rel=\"noopener\">Norcodeine<\/a><\/td><td class=\"oth\">2.96<\/td><td class=\"oth\">25<\/td><td class=\"oth\">286.1<\/td><td class=\"oth\">151.9<\/td><td class=\"oth\">115.0<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Olanzapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/132539-06-1\/Olanzapine\" target=\"_blank\" rel=\"noopener\">Olanzapine<\/a><\/td><td class=\"oth\">3.12<\/td><td class=\"oth\">25<\/td><td class=\"oth\">313.2<\/td><td class=\"oth\">256.1<\/td><td class=\"oth\">198.1<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methamphetamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/537-46-2\/Methamphetamine\" target=\"_blank\" rel=\"noopener\">Methamphetamine<\/a><\/td><td class=\"oth\">3.13<\/td><td class=\"oth\">25<\/td><td class=\"oth\">150.3<\/td><td class=\"oth\">91.1<\/td><td class=\"oth\">119.0<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for MDA\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/4764-17-4\/MDA\" target=\"_blank\" rel=\"noopener\">MDA<\/a><\/td><td class=\"oth\">3.18<\/td><td class=\"oth\">25<\/td><td class=\"oth\">180.1<\/td><td class=\"oth\">163.1<\/td><td class=\"oth\">105.2<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (-)-Naloxone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/465-65-6\/(-)-Naloxone\" target=\"_blank\" rel=\"noopener\">(-)-Naloxone<\/a><\/td><td class=\"oth\">3.27<\/td><td class=\"oth\">25<\/td><td class=\"oth\">328.3<\/td><td class=\"oth\">310.1<\/td><td class=\"oth\">212.3<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phentermine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/122-09-8\/Phentermine\" target=\"_blank\" rel=\"noopener\">Phentermine<\/a><\/td><td class=\"oth\">3.29<\/td><td class=\"oth\">25<\/td><td class=\"oth\">150.2<\/td><td class=\"oth\">91.1<\/td><td class=\"oth\">133.1<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Noroxycodone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57664-96-7\/Noroxycodone\" target=\"_blank\" rel=\"noopener\">Noroxycodone<\/a><\/td><td class=\"oth\">3.32<\/td><td class=\"oth\">25<\/td><td class=\"oth\">302.1<\/td><td class=\"oth\">227.0<\/td><td class=\"oth\">197.9<\/td><\/tr>\n<tr><td class=\"num\">29.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methylone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/186028-79-5\/Methylone\" target=\"_blank\" rel=\"noopener\">Methylone<\/a><\/td><td class=\"oth\">3.36<\/td><td class=\"oth\">25<\/td><td class=\"oth\">208.1<\/td><td class=\"oth\">160.1<\/td><td class=\"oth\">132.1<\/td><\/tr>\n<tr><td class=\"num\">30.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for O-Desmethyl-cis-tramadol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/144830-14-8\/O-Desmethyl-cis-tramadol\" target=\"_blank\" rel=\"noopener\">O-Desmethyl-cis-tramadol<\/a><\/td><td class=\"oth\">3.37<\/td><td class=\"oth\">25<\/td><td class=\"oth\">250.1<\/td><td class=\"oth\">58.0<\/td><td class=\"oth\">42.0<\/td><\/tr>\n<tr><td class=\"num\">31.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (-)-Dihydrocodeine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/125-28-0\/(-)-Dihydrocodeine\" target=\"_blank\" rel=\"noopener\">(-)-Dihydrocodeine<\/a><\/td><td class=\"oth\">3.38<\/td><td class=\"oth\">25<\/td><td class=\"oth\">302.2<\/td><td class=\"oth\">199.0<\/td><td class=\"oth\">128.2<\/td><\/tr>\n<tr><td class=\"num\">32.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norhydrocodone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5083-62-5\/Norhydrocodone\" target=\"_blank\" rel=\"noopener\">Norhydrocodone<\/a><\/td><td class=\"oth\">3.43<\/td><td class=\"oth\">25<\/td><td class=\"oth\">286.1<\/td><td class=\"oth\">199.0<\/td><td class=\"oth\">128.2<\/td><\/tr>\n<tr><td class=\"num\">33.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Codeine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-57-3\/Codeine\" target=\"_blank\" rel=\"noopener\">Codeine<\/a><\/td><td class=\"oth\">3.43<\/td><td class=\"oth\">25<\/td><td class=\"oth\">300.2<\/td><td class=\"oth\">152.0<\/td><td class=\"oth\">165.1<\/td><\/tr>\n<tr><td class=\"num\">34.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 6-Acetylmorphine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2784-73-8\/6-Acetylmorphine\" target=\"_blank\" rel=\"noopener\">6-Acetylmorphine<\/a><\/td><td class=\"oth\">3.47<\/td><td class=\"oth\">25<\/td><td class=\"oth\">328.2<\/td><td class=\"oth\">165.0<\/td><td class=\"oth\">211.0<\/td><\/tr>\n<tr><td class=\"num\">35.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for MDMA\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/42542-10-9\/MDMA\" target=\"_blank\" rel=\"noopener\">MDMA<\/a><\/td><td class=\"oth\">3.60<\/td><td class=\"oth\">25<\/td><td class=\"oth\">194.2<\/td><td class=\"oth\">163.0<\/td><td class=\"oth\">135.1<\/td><\/tr>\n<tr><td class=\"num\">36.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Desomorphine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/427-00-9\/Desomorphine\" target=\"_blank\" rel=\"noopener\">Desomorphine<\/a><\/td><td class=\"oth\">3.61<\/td><td class=\"oth\">25<\/td><td class=\"oth\">272.1<\/td><td class=\"oth\">152.1<\/td><td class=\"oth\">165.0<\/td><\/tr>\n<tr><td class=\"num\">37.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Oxycodone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-42-6\/Oxycodone\" target=\"_blank\" rel=\"noopener\">Oxycodone<\/a><\/td><td class=\"oth\">3.64<\/td><td class=\"oth\">25<\/td><td class=\"oth\">316.2<\/td><td class=\"oth\">298.0<\/td><td class=\"oth\">169.0<\/td><\/tr>\n<tr><td class=\"num\">38.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Naltrexone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/16590-41-3\/Naltrexone\" target=\"_blank\" rel=\"noopener\">Naltrexone<\/a><\/td><td class=\"oth\">3.71<\/td><td class=\"oth\">25<\/td><td class=\"oth\">342.2<\/td><td class=\"oth\">324.0<\/td><td class=\"oth\">267.0<\/td><\/tr>\n<tr><td class=\"num\">39.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Levamisole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/14769-73-4\/Levamisole\" target=\"_blank\" rel=\"noopener\">Levamisole<\/a><\/td><td class=\"oth\">3.75<\/td><td class=\"oth\">25<\/td><td class=\"oth\">205.1<\/td><td class=\"oth\">178.0<\/td><td class=\"oth\">91.1<\/td><\/tr>\n<tr><td class=\"num\">40.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hydrocodone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/125-29-1\/Hydrocodone\" target=\"_blank\" rel=\"noopener\">Hydrocodone<\/a><\/td><td class=\"oth\">3.76<\/td><td class=\"oth\">25<\/td><td class=\"oth\">300.1<\/td><td class=\"oth\">199.0<\/td><td class=\"oth\">128.0<\/td><\/tr>\n<tr><td class=\"num\">41.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diethylpropion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90-84-6\/Diethylpropion\" target=\"_blank\" rel=\"noopener\">Diethylpropion<\/a><\/td><td class=\"oth\">3.80<\/td><td class=\"oth\">25<\/td><td class=\"oth\">206.2<\/td><td class=\"oth\">105.1<\/td><td class=\"oth\">100.1<\/td><\/tr>\n<tr><td class=\"num\">42.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mephedrone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1189726-22-4\/Mephedrone\" target=\"_blank\" rel=\"noopener\">Mephedrone<\/a><\/td><td class=\"oth\">3.80<\/td><td class=\"oth\">25<\/td><td class=\"oth\">178.2<\/td><td class=\"oth\">145.0<\/td><td class=\"oth\">160.1<\/td><\/tr>\n<tr><td class=\"num\">43.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Oxo-3-hydroxy-LSD\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111295-09-1\/2-Oxo-3-hydroxy-LSD\" target=\"_blank\" rel=\"noopener\">2-Oxo-3-hydroxy-LSD<\/a><\/td><td class=\"oth\">3.82<\/td><td class=\"oth\">25<\/td><td class=\"oth\">356.3<\/td><td class=\"oth\">237.0<\/td><td class=\"oth\">222.0<\/td><\/tr>\n<tr><td class=\"num\">44.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for o-Desmethylvenlafaxine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/93413-62-8\/o-Desmethylvenlafaxine\" target=\"_blank\" rel=\"noopener\">o-Desmethylvenlafaxine<\/a><\/td><td class=\"oth\">3.84<\/td><td class=\"oth\">25<\/td><td class=\"oth\">264.1<\/td><td class=\"oth\">58.1<\/td><td class=\"oth\">107.0<\/td><\/tr>\n<tr><td class=\"num\">45.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 6-\u03b2-Naltrexol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/49625-89-0\/6-\u03b2-Naltrexol\" target=\"_blank\" rel=\"noopener\">6-\u03b2-Naltrexol<\/a><\/td><td class=\"oth\">3.91<\/td><td class=\"oth\">25<\/td><td class=\"oth\">344.3<\/td><td class=\"oth\">326.1<\/td><td class=\"oth\">308.1<\/td><\/tr>\n<tr><td class=\"num\">46.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tapentadol-\u03b2-D-glucuronide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1300037-86-8\/Tapentadol-\u03b2-D-glucuronide\" target=\"_blank\" rel=\"noopener\">Tapentadol-\u03b2-D-glucuronide<\/a><\/td><td class=\"oth\">3.91<\/td><td class=\"oth\">25<\/td><td class=\"oth\">398.3<\/td><td class=\"oth\">222.1<\/td><td class=\"oth\">107.0<\/td><\/tr>\n<tr><td class=\"num\">47.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 7-Aminonitrazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/4928-02-3\/7-Aminonitrazepam\" target=\"_blank\" rel=\"noopener\">7-Aminonitrazepam<\/a><\/td><td class=\"oth\">3.95<\/td><td class=\"oth\">25<\/td><td class=\"oth\">252.2<\/td><td class=\"oth\">121.1<\/td><td class=\"oth\">94.2<\/td><\/tr>\n<tr><td class=\"num\">48.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for MDEA\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/82801-81-8\/MDEA\" target=\"_blank\" rel=\"noopener\">MDEA<\/a><\/td><td class=\"oth\">4.00<\/td><td class=\"oth\">25<\/td><td class=\"oth\">208.1<\/td><td class=\"oth\">163.0<\/td><td class=\"oth\">105.2<\/td><\/tr>\n<tr><td class=\"num\">49.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for m-Hydroxybenzoylecgonine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/129944-99-6\/m-Hydroxybenzoylecgonine\" target=\"_blank\" rel=\"noopener\">m-Hydroxybenzoylecgonine<\/a><\/td><td class=\"oth\">4.02<\/td><td class=\"oth\">25<\/td><td class=\"oth\">306.1<\/td><td class=\"oth\">168.1<\/td><td class=\"oth\">121.0<\/td><\/tr>\n<tr><td class=\"num\">50.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Lamotrigine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/84057-84-1\/Lamotrigine\" target=\"_blank\" rel=\"noopener\">Lamotrigine<\/a><\/td><td class=\"oth\">4.09<\/td><td class=\"oth\">25<\/td><td class=\"oth\">256.0<\/td><td class=\"oth\">211.1<\/td><td class=\"oth\">145.0<\/td><\/tr>\n<tr><td class=\"num\">51.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ritalinic acid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/54631-24-2\/Ritalinic acid\" target=\"_blank\" rel=\"noopener\">Ritalinic acid<\/a><\/td><td class=\"oth\">4.11<\/td><td class=\"oth\">25<\/td><td class=\"oth\">220.1<\/td><td class=\"oth\">84.1<\/td><td class=\"oth\">56.2<\/td><\/tr>\n<tr><td class=\"num\">52.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Desmethyltapentadol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1246819-18-0\/N-Desmethyltapentadol\" target=\"_blank\" rel=\"noopener\">N-Desmethyltapentadol<\/a><\/td><td class=\"oth\">4.16<\/td><td class=\"oth\">25<\/td><td class=\"oth\">208.1<\/td><td class=\"oth\">121.2<\/td><td class=\"oth\">107.1<\/td><\/tr>\n<tr><td class=\"num\">53.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norbuprenorphine glucuronide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/469887-29-4\/Norbuprenorphine glucuronide\" target=\"_blank\" rel=\"noopener\">Norbuprenorphine glucuronide<\/a><\/td><td class=\"oth\">4.18<\/td><td class=\"oth\">25<\/td><td class=\"oth\">590.5<\/td><td class=\"oth\">414.3<\/td><td class=\"oth\">165.0<\/td><\/tr>\n<tr><td class=\"num\">54.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Zonisamide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/68291-97-4\/Zonisamide\" target=\"_blank\" rel=\"noopener\">Zonisamide<\/a><\/td><td class=\"oth\">4.23<\/td><td class=\"oth\">25<\/td><td class=\"oth\">212.9<\/td><td class=\"oth\">132.1<\/td><td class=\"oth\">77.1<\/td><\/tr>\n<tr><td class=\"num\">55.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for mCPP\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/6640-24-0\/mCPP\" target=\"_blank\" rel=\"noopener\">mCPP<\/a><\/td><td class=\"oth\">4.26<\/td><td class=\"oth\">25<\/td><td class=\"oth\">197.1<\/td><td class=\"oth\">154.0<\/td><td class=\"oth\">118.1<\/td><\/tr>\n<tr><td class=\"num\">56.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norketamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/79499-59-5\/Norketamine\" target=\"_blank\" rel=\"noopener\">Norketamine<\/a><\/td><td class=\"oth\">4.28<\/td><td class=\"oth\">25<\/td><td class=\"oth\">224.1<\/td><td class=\"oth\">125.0<\/td><td class=\"oth\">89.1<\/td><\/tr>\n<tr><td class=\"num\">57.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nalbuphine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/20594-83-6\/Nalbuphine\" target=\"_blank\" rel=\"noopener\">Nalbuphine<\/a><\/td><td class=\"oth\">4.33<\/td><td class=\"oth\">25<\/td><td class=\"oth\">358.2<\/td><td class=\"oth\">340.1<\/td><td class=\"oth\">115.0<\/td><\/tr>\n<tr><td class=\"num\">58.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norfentanyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1609-66-1\/Norfentanyl\" target=\"_blank\" rel=\"noopener\">Norfentanyl<\/a><\/td><td class=\"oth\">4.33<\/td><td class=\"oth\">25<\/td><td class=\"oth\">233.1<\/td><td class=\"oth\">84.1<\/td><td class=\"oth\">55.0<\/td><\/tr>\n<tr><td class=\"num\">59.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (+\/-)-Hydroxybupropion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92264-81-8\/(+_-)-Hydroxybupropion\" target=\"_blank\" rel=\"noopener\">(+\/-)-Hydroxybupropion<\/a><\/td><td class=\"oth\">4.35<\/td><td class=\"oth\">25<\/td><td class=\"oth\">256.0<\/td><td class=\"oth\">130.2<\/td><td class=\"oth\">166.0<\/td><\/tr>\n<tr><td class=\"num\">60.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tapentadol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/175591-23-8\/Tapentadol\" target=\"_blank\" rel=\"noopener\">Tapentadol<\/a><\/td><td class=\"oth\">4.37<\/td><td class=\"oth\">25<\/td><td class=\"oth\">222.1<\/td><td class=\"oth\">107.1<\/td><td class=\"oth\">121.0<\/td><\/tr>\n<tr><td class=\"num\">61.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Lacosamide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/175481-36-4\/Lacosamide\" target=\"_blank\" rel=\"noopener\">Lacosamide<\/a><\/td><td class=\"oth\">4.47<\/td><td class=\"oth\">25<\/td><td class=\"oth\">251.5<\/td><td class=\"oth\">91.1<\/td><td class=\"oth\">108.1<\/td><\/tr>\n<tr><td class=\"num\">62.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dextrorphan\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/125-73-5\/Dextrorphan\" target=\"_blank\" rel=\"noopener\">Dextrorphan<\/a><\/td><td class=\"oth\">4.50<\/td><td class=\"oth\">25<\/td><td class=\"oth\">258.2<\/td><td class=\"oth\">157.0<\/td><td class=\"oth\">201.2<\/td><\/tr>\n<tr><td class=\"num\">63.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Levorphanol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/77-07-6\/Levorphanol\" target=\"_blank\" rel=\"noopener\">Levorphanol<\/a><\/td><td class=\"oth\">4.50<\/td><td class=\"oth\">25<\/td><td class=\"oth\">258.2<\/td><td class=\"oth\">156.8<\/td><td class=\"oth\">199.2<\/td><\/tr>\n<tr><td class=\"num\">64.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 7-Hydroxyquetiapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/139079-39-3\/7-Hydroxyquetiapine\" target=\"_blank\" rel=\"noopener\">7-Hydroxyquetiapine<\/a><\/td><td class=\"oth\">4.51<\/td><td class=\"oth\">25<\/td><td class=\"oth\">400.3<\/td><td class=\"oth\">269.0<\/td><td class=\"oth\">208.0<\/td><\/tr>\n<tr><td class=\"num\">65.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Molindone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7416-34-4\/Molindone\" target=\"_blank\" rel=\"noopener\">Molindone<\/a><\/td><td class=\"oth\">4.51<\/td><td class=\"oth\">25<\/td><td class=\"oth\">277.2<\/td><td class=\"oth\">100.1<\/td><td class=\"oth\">70.2<\/td><\/tr>\n<tr><td class=\"num\">66.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tramadol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/27203-92-5\/Tramadol\" target=\"_blank\" rel=\"noopener\">Tramadol<\/a><\/td><td class=\"oth\">4.52<\/td><td class=\"oth\">25<\/td><td class=\"oth\">264.2<\/td><td class=\"oth\">58.0<\/td><td class=\"oth\">77.1<\/td><\/tr>\n<tr><td class=\"num\">67.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Zolpidem phenyl-4-carboxylic acid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/109461-65-6\/Zolpidem phenyl-4-carboxylic acid\" target=\"_blank\" rel=\"noopener\">Zolpidem phenyl-4-carboxylic acid<\/a><\/td><td class=\"oth\">4.60<\/td><td class=\"oth\">25<\/td><td class=\"oth\">338.2<\/td><td class=\"oth\">265.1<\/td><td class=\"oth\">219.0<\/td><\/tr>\n<tr><td class=\"num\">68.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Felbamate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/25451-15-4\/Felbamate\" target=\"_blank\" rel=\"noopener\">Felbamate<\/a><\/td><td class=\"oth\">4.62<\/td><td class=\"oth\">25<\/td><td class=\"oth\">239.1<\/td><td class=\"oth\">117.1<\/td><td class=\"oth\">177.8<\/td><\/tr>\n<tr><td class=\"num\">69.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Desmethyl-cis-tramadol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1018989-94-0\/N-Desmethyl-cis-tramadol\" target=\"_blank\" rel=\"noopener\">N-Desmethyl-cis-tramadol<\/a><\/td><td class=\"oth\">4.65<\/td><td class=\"oth\">25<\/td><td class=\"oth\">250.2<\/td><td class=\"oth\">44.0<\/td><td class=\"oth\">232.1<\/td><\/tr>\n<tr><td class=\"num\">70.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ketamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/6740-88-1\/Ketamine\" target=\"_blank\" rel=\"noopener\">Ketamine<\/a><\/td><td class=\"oth\">4.66<\/td><td class=\"oth\">25<\/td><td class=\"oth\">238.1<\/td><td class=\"oth\">125.1<\/td><td class=\"oth\">89.1<\/td><\/tr>\n<tr><td class=\"num\">71.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzoylecgonine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/519-09-5\/Benzoylecgonine\" target=\"_blank\" rel=\"noopener\">Benzoylecgonine<\/a><\/td><td class=\"oth\">4.67<\/td><td class=\"oth\">25<\/td><td class=\"oth\">290.1<\/td><td class=\"oth\">168.1<\/td><td class=\"oth\">77.1<\/td><\/tr>\n<tr><td class=\"num\">72.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methylphenidate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/113-45-1\/Methylphenidate\" target=\"_blank\" rel=\"noopener\">Methylphenidate<\/a><\/td><td class=\"oth\">4.68<\/td><td class=\"oth\">25<\/td><td class=\"oth\">234.1<\/td><td class=\"oth\">84.1<\/td><td class=\"oth\">56.1<\/td><\/tr>\n<tr><td class=\"num\">73.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Normeperidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/77-17-8\/Normeperidine\" target=\"_blank\" rel=\"noopener\">Normeperidine<\/a><\/td><td class=\"oth\">4.76<\/td><td class=\"oth\">25<\/td><td class=\"oth\">234.1<\/td><td class=\"oth\">160.2<\/td><td class=\"oth\">91.0<\/td><\/tr>\n<tr><td class=\"num\">74.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Meprobamate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57-53-4\/Meprobamate\" target=\"_blank\" rel=\"noopener\">Meprobamate<\/a><\/td><td class=\"oth\">4.79<\/td><td class=\"oth\">25<\/td><td class=\"oth\">219.1<\/td><td class=\"oth\">158.2<\/td><td class=\"oth\">97.0<\/td><\/tr>\n<tr><td class=\"num\">75.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Meperidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57-42-1\/Meperidine\" target=\"_blank\" rel=\"noopener\">Meperidine<\/a><\/td><td class=\"oth\">4.80<\/td><td class=\"oth\">25<\/td><td class=\"oth\">248.1<\/td><td class=\"oth\">220.1<\/td><td class=\"oth\">174.1<\/td><\/tr>\n<tr><td class=\"num\">76.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bupropion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/34911-55-2\/Bupropion\" target=\"_blank\" rel=\"noopener\">Bupropion<\/a><\/td><td class=\"oth\">4.81<\/td><td class=\"oth\">25<\/td><td class=\"oth\">240.0<\/td><td class=\"oth\">184.1<\/td><td class=\"oth\">130.2<\/td><\/tr>\n<tr><td class=\"num\">77.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Heroin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/561-27-3\/Heroin\" target=\"_blank\" rel=\"noopener\">Heroin<\/a><\/td><td class=\"oth\">4.85<\/td><td class=\"oth\">25<\/td><td class=\"oth\">370.4<\/td><td class=\"oth\">328.2<\/td><td class=\"oth\">164.9<\/td><\/tr>\n<tr><td class=\"num\">78.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cocaine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-36-2\/Cocaine\" target=\"_blank\" rel=\"noopener\">Cocaine<\/a><\/td><td class=\"oth\">5.01<\/td><td class=\"oth\">25<\/td><td class=\"oth\">304.2<\/td><td class=\"oth\">182.0<\/td><td class=\"oth\">77.1<\/td><\/tr>\n<tr><td class=\"num\">79.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 7-Aminoclonazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/4959-17-5\/7-Aminoclonazepam\" target=\"_blank\" rel=\"noopener\">7-Aminoclonazepam<\/a><\/td><td class=\"oth\">5.02<\/td><td class=\"oth\">25<\/td><td class=\"oth\">286.1<\/td><td class=\"oth\">121.2<\/td><td class=\"oth\">250.1<\/td><\/tr>\n<tr><td class=\"num\">80.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Zopiclone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/43200-80-2\/Zopiclone\" target=\"_blank\" rel=\"noopener\">Zopiclone<\/a><\/td><td class=\"oth\">5.04<\/td><td class=\"oth\">25<\/td><td class=\"oth\">389.2<\/td><td class=\"oth\">245.0<\/td><td class=\"oth\">217.2<\/td><\/tr>\n<tr><td class=\"num\">81.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Desmethylmirtazapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/61337-68-6\/N-Desmethylmirtazapine\" target=\"_blank\" rel=\"noopener\">N-Desmethylmirtazapine<\/a><\/td><td class=\"oth\">5.10<\/td><td class=\"oth\">25<\/td><td class=\"oth\">252.1<\/td><td class=\"oth\">195.1<\/td><td class=\"oth\">209.2<\/td><\/tr>\n<tr><td class=\"num\">82.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norcocaine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/18717-72-1\/Norcocaine\" target=\"_blank\" rel=\"noopener\">Norcocaine<\/a><\/td><td class=\"oth\">5.11<\/td><td class=\"oth\">25<\/td><td class=\"oth\">290.1<\/td><td class=\"oth\">168.0<\/td><td class=\"oth\">136.1<\/td><\/tr>\n<tr><td class=\"num\">83.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenobarbital*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-06-6\/Phenobarbital\" target=\"_blank\" rel=\"noopener\">Phenobarbital*<\/a><\/td><td class=\"oth\">5.11<\/td><td class=\"oth\">500<\/td><td class=\"oth\">230.9<\/td><td class=\"oth\">187.8<\/td><td class=\"oth\">85.0<\/td><\/tr>\n<tr><td class=\"num\">84.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Buprenorphine glucuronide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/101224-22-0\/Buprenorphine glucuronide\" target=\"_blank\" rel=\"noopener\">Buprenorphine glucuronide<\/a><\/td><td class=\"oth\">5.12<\/td><td class=\"oth\">25<\/td><td class=\"oth\">644.3<\/td><td class=\"oth\">468.2<\/td><td class=\"oth\">55.1<\/td><\/tr>\n<tr><td class=\"num\">85.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for MDPV\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/24622-62-6\/MDPV\" target=\"_blank\" rel=\"noopener\">MDPV<\/a><\/td><td class=\"oth\">5.15<\/td><td class=\"oth\">25<\/td><td class=\"oth\">276.2<\/td><td class=\"oth\">135.1<\/td><td class=\"oth\">126.1<\/td><\/tr>\n<tr><td class=\"num\">86.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Venlafaxine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/93413-69-5\/Venlafaxine\" target=\"_blank\" rel=\"noopener\">Venlafaxine<\/a><\/td><td class=\"oth\">5.15<\/td><td class=\"oth\">25<\/td><td class=\"oth\">278.4<\/td><td class=\"oth\">260.4<\/td><td class=\"oth\">121.2<\/td><\/tr>\n<tr><td class=\"num\">87.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Milnacipran\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92623-85-3\/Milnacipran\" target=\"_blank\" rel=\"noopener\">Milnacipran<\/a><\/td><td class=\"oth\">5.24<\/td><td class=\"oth\">25<\/td><td class=\"oth\">247.2<\/td><td class=\"oth\">100.1<\/td><td class=\"oth\">129.1<\/td><\/tr>\n<tr><td class=\"num\">88.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentazocine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/359-83-1\/Pentazocine\" target=\"_blank\" rel=\"noopener\">Pentazocine<\/a><\/td><td class=\"oth\">5.29<\/td><td class=\"oth\">25<\/td><td class=\"oth\">286.2<\/td><td class=\"oth\">218.1<\/td><td class=\"oth\">69.2<\/td><\/tr>\n<tr><td class=\"num\">89.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mirtazapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85650-52-8\/Mirtazapine\" target=\"_blank\" rel=\"noopener\">Mirtazapine<\/a><\/td><td class=\"oth\">5.31<\/td><td class=\"oth\">25<\/td><td class=\"oth\">266.1<\/td><td class=\"oth\">195.1<\/td><td class=\"oth\">72.1<\/td><\/tr>\n<tr><td class=\"num\">90.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Butalbital*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/77-26-9\/Butalbital\" target=\"_blank\" rel=\"noopener\">Butalbital*<\/a><\/td><td class=\"oth\">5.31<\/td><td class=\"oth\">500<\/td><td class=\"oth\">223.0<\/td><td class=\"oth\">180.0<\/td><td class=\"oth\">84.9<\/td><\/tr>\n<tr><td class=\"num\">91.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norbuprenorphine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78715-23-8\/Norbuprenorphine\" target=\"_blank\" rel=\"noopener\">Norbuprenorphine<\/a><\/td><td class=\"oth\">5.35<\/td><td class=\"oth\">50<\/td><td class=\"oth\">414.3<\/td><td class=\"oth\">152.2<\/td><td class=\"oth\">165.2<\/td><\/tr>\n<tr><td class=\"num\">92.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for LSD\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-37-3\/LSD\" target=\"_blank\" rel=\"noopener\">LSD<\/a><\/td><td class=\"oth\">5.39<\/td><td class=\"oth\">25<\/td><td class=\"oth\">324.3<\/td><td class=\"oth\">223.1<\/td><td class=\"oth\">208.0<\/td><\/tr>\n<tr><td class=\"num\">93.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Butorphanol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/42408-82-2\/Butorphanol\" target=\"_blank\" rel=\"noopener\">Butorphanol<\/a><\/td><td class=\"oth\">5.43<\/td><td class=\"oth\">25<\/td><td class=\"oth\">328.3<\/td><td class=\"oth\">310.3<\/td><td class=\"oth\">131.2<\/td><\/tr>\n<tr><td class=\"num\">94.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fosphenytoin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/93390-81-9\/Fosphenytoin\" target=\"_blank\" rel=\"noopener\">Fosphenytoin<\/a><\/td><td class=\"oth\">5.43<\/td><td class=\"oth\">25<\/td><td class=\"oth\">363.1<\/td><td class=\"oth\">265.9<\/td><td class=\"oth\">207.8<\/td><\/tr>\n<tr><td class=\"num\">95.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Topiramate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/97240-79-4\/Topiramate\" target=\"_blank\" rel=\"noopener\">Topiramate<\/a><\/td><td class=\"oth\">5.44<\/td><td class=\"oth\">25<\/td><td class=\"oth\">340.2<\/td><td class=\"oth\">264.2<\/td><td class=\"oth\">223.9<\/td><\/tr>\n<tr><td class=\"num\">96.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cocaethylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/529-38-4\/Cocaethylene\" target=\"_blank\" rel=\"noopener\">Cocaethylene<\/a><\/td><td class=\"oth\">5.48<\/td><td class=\"oth\">25<\/td><td class=\"oth\">318.2<\/td><td class=\"oth\">196.1<\/td><td class=\"oth\">82.0<\/td><\/tr>\n<tr><td class=\"num\">97.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Clozapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5786-21-0\/Clozapine\" target=\"_blank\" rel=\"noopener\">Clozapine<\/a><\/td><td class=\"oth\">5.48<\/td><td class=\"oth\">25<\/td><td class=\"oth\">328.2<\/td><td class=\"oth\">271.1<\/td><td class=\"oth\">193.1<\/td><\/tr>\n<tr><td class=\"num\">98.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 9-Hydroxyrisperidone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/144598-75-4\/9-Hydroxyrisperidone\" target=\"_blank\" rel=\"noopener\">9-Hydroxyrisperidone<\/a><\/td><td class=\"oth\">5.51<\/td><td class=\"oth\">25<\/td><td class=\"oth\">427.3<\/td><td class=\"oth\">207.1<\/td><td class=\"oth\">110.2<\/td><\/tr>\n<tr><td class=\"num\">99.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetyl fentanyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3258-84-2\/Acetyl fentanyl\" target=\"_blank\" rel=\"noopener\">Acetyl fentanyl<\/a><\/td><td class=\"oth\">5.58<\/td><td class=\"oth\">25<\/td><td class=\"oth\">323.3<\/td><td class=\"oth\">188.0<\/td><td class=\"oth\">105.0<\/td><\/tr>\n<tr><td class=\"num\">100.<\/td><td class=\"cmpd\">Didesmethyl citalopram HCl<\/td><td class=\"oth\">5.73<\/td><td class=\"oth\">25<\/td><td class=\"oth\">297.1<\/td><td class=\"oth\">261.9<\/td><td class=\"oth\">109.1<\/td><\/tr>\n<tr><td class=\"num\">101.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 7-Aminoflunitrazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/34084-50-9\/7-Aminoflunitrazepam\" target=\"_blank\" rel=\"noopener\">7-Aminoflunitrazepam<\/a><\/td><td class=\"oth\">5.75<\/td><td class=\"oth\">25<\/td><td class=\"oth\">284.1<\/td><td class=\"oth\">135.0<\/td><td class=\"oth\">227.1<\/td><\/tr>\n<tr><td class=\"num\">102.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Amobarbital*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57-43-2\/Amobarbital\" target=\"_blank\" rel=\"noopener\">Amobarbital*<\/a><\/td><td class=\"oth\">5.75<\/td><td class=\"oth\">500<\/td><td class=\"oth\">225.0<\/td><td class=\"oth\">182.0<\/td><td class=\"oth\">84.8<\/td><\/tr>\n<tr><td class=\"num\">103.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Zolpidem\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/82626-48-0\/Zolpidem\" target=\"_blank\" rel=\"noopener\">Zolpidem<\/a><\/td><td class=\"oth\">5.76<\/td><td class=\"oth\">25<\/td><td class=\"oth\">308.2<\/td><td class=\"oth\">235.2<\/td><td class=\"oth\">218.9<\/td><\/tr>\n<tr><td class=\"num\">104.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Desmethylcitalopram\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62498-67-3\/N-Desmethylcitalopram\" target=\"_blank\" rel=\"noopener\">N-Desmethylcitalopram<\/a><\/td><td class=\"oth\">5.77<\/td><td class=\"oth\">25<\/td><td class=\"oth\">311.1<\/td><td class=\"oth\">262.1<\/td><td class=\"oth\">109.1<\/td><\/tr>\n<tr><td class=\"num\">105.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isocarboxazid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59-63-2\/Isocarboxazid\" target=\"_blank\" rel=\"noopener\">Isocarboxazid<\/a><\/td><td class=\"oth\">5.77<\/td><td class=\"oth\">25<\/td><td class=\"oth\">232.0<\/td><td class=\"oth\">91.1<\/td><td class=\"oth\">65.2<\/td><\/tr>\n<tr><td class=\"num\">106.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentobarbital*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-74-4\/Pentobarbital\" target=\"_blank\" rel=\"noopener\">Pentobarbital*<\/a><\/td><td class=\"oth\">5.79<\/td><td class=\"oth\">500<\/td><td class=\"oth\">225.0<\/td><td class=\"oth\">182.0<\/td><td class=\"oth\">84.9<\/td><\/tr>\n<tr><td class=\"num\">107.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Escitalopram\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/128196-01-0\/Escitalopram\" target=\"_blank\" rel=\"noopener\">Escitalopram<\/a><\/td><td class=\"oth\">5.80<\/td><td class=\"oth\">25<\/td><td class=\"oth\">325.3<\/td><td class=\"oth\">109.1<\/td><td class=\"oth\">261.9<\/td><\/tr>\n<tr><td class=\"num\">108.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Citalopram\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59729-33-8\/Citalopram\" target=\"_blank\" rel=\"noopener\">Citalopram<\/a><\/td><td class=\"oth\">5.80<\/td><td class=\"oth\">25<\/td><td class=\"oth\">325.2<\/td><td class=\"oth\">109.1<\/td><td class=\"oth\">262.0<\/td><\/tr>\n<tr><td class=\"num\">109.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diphenhydramine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/58-73-1\/Diphenhydramine\" target=\"_blank\" rel=\"noopener\">Diphenhydramine<\/a><\/td><td class=\"oth\">5.80<\/td><td class=\"oth\">25<\/td><td class=\"oth\">256.1<\/td><td class=\"oth\">167.0<\/td><td class=\"oth\">152.1<\/td><\/tr>\n<tr><td class=\"num\">110.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Desmethyldoxepin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1225-56-5\/Desmethyldoxepin\" target=\"_blank\" rel=\"noopener\">Desmethyldoxepin<\/a><\/td><td class=\"oth\">5.88<\/td><td class=\"oth\">25<\/td><td class=\"oth\">266.1<\/td><td class=\"oth\">107.1<\/td><td class=\"oth\">115.0<\/td><\/tr>\n<tr><td class=\"num\">111.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ezogabine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/150812-12-7\/Ezogabine\" target=\"_blank\" rel=\"noopener\">Ezogabine<\/a><\/td><td class=\"oth\">5.91<\/td><td class=\"oth\">25<\/td><td class=\"oth\">304.0<\/td><td class=\"oth\">230.1<\/td><td class=\"oth\">109.1<\/td><\/tr>\n<tr><td class=\"num\">112.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Doxepin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1668-19-5\/Doxepin\" target=\"_blank\" rel=\"noopener\">Doxepin<\/a><\/td><td class=\"oth\">5.96<\/td><td class=\"oth\">25<\/td><td class=\"oth\">280.1<\/td><td class=\"oth\">107.2<\/td><td class=\"oth\">77.1<\/td><\/tr>\n<tr><td class=\"num\">113.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Haloperidol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52-86-8\/Haloperidol\" target=\"_blank\" rel=\"noopener\">Haloperidol<\/a><\/td><td class=\"oth\">5.96<\/td><td class=\"oth\">25<\/td><td class=\"oth\">377.2<\/td><td class=\"oth\">123.0<\/td><td class=\"oth\">95.1<\/td><\/tr>\n<tr><td class=\"num\">114.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluvoxamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/54739-18-3\/Fluvoxamine\" target=\"_blank\" rel=\"noopener\">Fluvoxamine<\/a><\/td><td class=\"oth\">5.97<\/td><td class=\"oth\">25<\/td><td class=\"oth\">319.3<\/td><td class=\"oth\">71.1<\/td><td class=\"oth\">257.8<\/td><\/tr>\n<tr><td class=\"num\">115.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Trazodone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/19794-93-5\/Trazodone\" target=\"_blank\" rel=\"noopener\">Trazodone<\/a><\/td><td class=\"oth\">5.99<\/td><td class=\"oth\">25<\/td><td class=\"oth\">372.3<\/td><td class=\"oth\">176.1<\/td><td class=\"oth\">148.0<\/td><\/tr>\n<tr><td class=\"num\">116.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norfluoxetine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56161-73-0\/Norfluoxetine\" target=\"_blank\" rel=\"noopener\">Norfluoxetine<\/a><\/td><td class=\"oth\">6.01<\/td><td class=\"oth\">25<\/td><td class=\"oth\">296.3<\/td><td class=\"oth\">134.3<\/td><td class=\"oth\">104.9<\/td><\/tr>\n<tr><td class=\"num\">117.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fentanyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/437-38-7\/Fentanyl\" target=\"_blank\" rel=\"noopener\">Fentanyl<\/a><\/td><td class=\"oth\">6.02<\/td><td class=\"oth\">25<\/td><td class=\"oth\">337.3<\/td><td class=\"oth\">188.0<\/td><td class=\"oth\">105.1<\/td><\/tr>\n<tr><td class=\"num\">118.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Oxcarbazepine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/28721-07-5\/Oxcarbazepine\" target=\"_blank\" rel=\"noopener\">Oxcarbazepine<\/a><\/td><td class=\"oth\">6.02<\/td><td class=\"oth\">25<\/td><td class=\"oth\">253.1<\/td><td class=\"oth\">180.0<\/td><td class=\"oth\">208.1<\/td><\/tr>\n<tr><td class=\"num\">119.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Risperidone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106266-06-2\/Risperidone\" target=\"_blank\" rel=\"noopener\">Risperidone<\/a><\/td><td class=\"oth\">6.03<\/td><td class=\"oth\">25<\/td><td class=\"oth\">411.2<\/td><td class=\"oth\">191.0<\/td><td class=\"oth\">110.1<\/td><\/tr>\n<tr><td class=\"num\">120.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Buprenorphine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52485-79-7\/Buprenorphine\" target=\"_blank\" rel=\"noopener\">Buprenorphine<\/a><\/td><td class=\"oth\">6.04<\/td><td class=\"oth\">50<\/td><td class=\"oth\">468.3<\/td><td class=\"oth\">55.1<\/td><td class=\"oth\">414.2<\/td><\/tr>\n<tr><td class=\"num\">121.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluoxetine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/54910-89-3\/Fluoxetine\" target=\"_blank\" rel=\"noopener\">Fluoxetine<\/a><\/td><td class=\"oth\">6.05<\/td><td class=\"oth\">25<\/td><td class=\"oth\">310.1<\/td><td class=\"oth\">148.0<\/td><td class=\"oth\">115.1<\/td><\/tr>\n<tr><td class=\"num\">122.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Secobarbital*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-73-3\/Secobarbital\" target=\"_blank\" rel=\"noopener\">Secobarbital*<\/a><\/td><td class=\"oth\">6.08<\/td><td class=\"oth\">500<\/td><td class=\"oth\">237.0<\/td><td class=\"oth\">193.9<\/td><td class=\"oth\">84.8<\/td><\/tr>\n<tr><td class=\"num\">123.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenytoin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57-41-0\/Phenytoin\" target=\"_blank\" rel=\"noopener\">Phenytoin<\/a><\/td><td class=\"oth\">6.12<\/td><td class=\"oth\">25<\/td><td class=\"oth\">253.0<\/td><td class=\"oth\">103.9<\/td><td class=\"oth\">181.7<\/td><\/tr>\n<tr><td class=\"num\">124.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carisoprodol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78-44-4\/Carisoprodol\" target=\"_blank\" rel=\"noopener\">Carisoprodol<\/a><\/td><td class=\"oth\">6.13<\/td><td class=\"oth\">25<\/td><td class=\"oth\">261.1<\/td><td class=\"oth\">176.0<\/td><td class=\"oth\">62.0<\/td><\/tr>\n<tr><td class=\"num\">125.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flurazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/17617-23-1\/Flurazepam\" target=\"_blank\" rel=\"noopener\">Flurazepam<\/a><\/td><td class=\"oth\">6.14<\/td><td class=\"oth\">25<\/td><td class=\"oth\">388.2<\/td><td class=\"oth\">315.2<\/td><td class=\"oth\">183.0<\/td><\/tr>\n<tr><td class=\"num\">126.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlordiazepoxide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/58-25-3\/Chlordiazepoxide\" target=\"_blank\" rel=\"noopener\">Chlordiazepoxide<\/a><\/td><td class=\"oth\">6.14<\/td><td class=\"oth\">25<\/td><td class=\"oth\">300.1<\/td><td class=\"oth\">282.0<\/td><td class=\"oth\">227.0<\/td><\/tr>\n<tr><td class=\"num\">127.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dextromethorphan\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/125-71-3\/Dextromethorphan\" target=\"_blank\" rel=\"noopener\">Dextromethorphan<\/a><\/td><td class=\"oth\">6.16<\/td><td class=\"oth\">25<\/td><td class=\"oth\">272.2<\/td><td class=\"oth\">215.1<\/td><td class=\"oth\">170.9<\/td><\/tr>\n<tr><td class=\"num\">128.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for PCP\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/77-10-1\/PCP\" target=\"_blank\" rel=\"noopener\">PCP<\/a><\/td><td class=\"oth\">6.18<\/td><td class=\"oth\">25<\/td><td class=\"oth\">244.2<\/td><td class=\"oth\">86.1<\/td><td class=\"oth\">159.1<\/td><\/tr>\n<tr><td class=\"num\">129.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tenoxicam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59804-37-4\/Tenoxicam\" target=\"_blank\" rel=\"noopener\">Tenoxicam<\/a><\/td><td class=\"oth\">6.18<\/td><td class=\"oth\">25<\/td><td class=\"oth\">338.1<\/td><td class=\"oth\">121.0<\/td><td class=\"oth\">95.0<\/td><\/tr>\n<tr><td class=\"num\">130.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Buspirone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/36505-84-7\/Buspirone\" target=\"_blank\" rel=\"noopener\">Buspirone<\/a><\/td><td class=\"oth\">6.20<\/td><td class=\"oth\">25<\/td><td class=\"oth\">386.3<\/td><td class=\"oth\">122.1<\/td><td class=\"oth\">95.0<\/td><\/tr>\n<tr><td class=\"num\">131.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Quetiapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111974-69-7\/Quetiapine\" target=\"_blank\" rel=\"noopener\">Quetiapine<\/a><\/td><td class=\"oth\">6.28<\/td><td class=\"oth\">25<\/td><td class=\"oth\">384.2<\/td><td class=\"oth\">253.0<\/td><td class=\"oth\">221.2<\/td><\/tr>\n<tr><td class=\"num\">132.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norpropoxyphene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/32501-12-5\/Norpropoxyphene\" target=\"_blank\" rel=\"noopener\">Norpropoxyphene<\/a><\/td><td class=\"oth\">6.29<\/td><td class=\"oth\">25<\/td><td class=\"oth\">326.4<\/td><td class=\"oth\">252.0<\/td><td class=\"oth\">91.1<\/td><\/tr>\n<tr><td class=\"num\">133.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propoxyphene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/469-62-5\/Propoxyphene\" target=\"_blank\" rel=\"noopener\">Propoxyphene<\/a><\/td><td class=\"oth\">6.30<\/td><td class=\"oth\">25<\/td><td class=\"oth\">340.3<\/td><td class=\"oth\">265.9<\/td><td class=\"oth\">58.1<\/td><\/tr>\n<tr><td class=\"num\">134.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Asenapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85650-56-2\/Asenapine\" target=\"_blank\" rel=\"noopener\">Asenapine<\/a><\/td><td class=\"oth\">6.35<\/td><td class=\"oth\">25<\/td><td class=\"oth\">286.2<\/td><td class=\"oth\">165.1<\/td><td class=\"oth\">229.1<\/td><\/tr>\n<tr><td class=\"num\">135.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ziprasidone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/146939-27-7\/Ziprasidone\" target=\"_blank\" rel=\"noopener\">Ziprasidone<\/a><\/td><td class=\"oth\">6.40<\/td><td class=\"oth\">25<\/td><td class=\"oth\">413.2<\/td><td class=\"oth\">194.1<\/td><td class=\"oth\">130.0<\/td><\/tr>\n<tr><td class=\"num\">136.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Protriptyline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/438-60-8\/Protriptyline\" target=\"_blank\" rel=\"noopener\">Protriptyline<\/a><\/td><td class=\"oth\">6.42<\/td><td class=\"oth\">25<\/td><td class=\"oth\">264.1<\/td><td class=\"oth\">191.1<\/td><td class=\"oth\">165.2<\/td><\/tr>\n<tr><td class=\"num\">137.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Promazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/58-40-2\/Promazine\" target=\"_blank\" rel=\"noopener\">Promazine<\/a><\/td><td class=\"oth\">6.42<\/td><td class=\"oth\">25<\/td><td class=\"oth\">285.1<\/td><td class=\"oth\">58.0<\/td><td class=\"oth\">86.0<\/td><\/tr>\n<tr><td class=\"num\">138.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Midazolam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59467-70-8\/Midazolam\" target=\"_blank\" rel=\"noopener\">Midazolam<\/a><\/td><td class=\"oth\">6.43<\/td><td class=\"oth\">25<\/td><td class=\"oth\">326.2<\/td><td class=\"oth\">291.1<\/td><td class=\"oth\">248.9<\/td><\/tr>\n<tr><td class=\"num\">139.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Desipramine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-47-5\/Desipramine\" target=\"_blank\" rel=\"noopener\">Desipramine<\/a><\/td><td class=\"oth\">6.43<\/td><td class=\"oth\">25<\/td><td class=\"oth\">267.1<\/td><td class=\"oth\">72.1<\/td><td class=\"oth\">193.1<\/td><\/tr>\n<tr><td class=\"num\">140.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Amoxapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/14028-44-5\/Amoxapine\" target=\"_blank\" rel=\"noopener\">Amoxapine<\/a><\/td><td class=\"oth\">6.44<\/td><td class=\"oth\">25<\/td><td class=\"oth\">314.2<\/td><td class=\"oth\">271.0<\/td><td class=\"oth\">193.1<\/td><\/tr>\n<tr><td class=\"num\">141.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Sufentanil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56030-54-7\/Sufentanil\" target=\"_blank\" rel=\"noopener\">Sufentanil<\/a><\/td><td class=\"oth\">6.48<\/td><td class=\"oth\">25<\/td><td class=\"oth\">387.2<\/td><td class=\"oth\">238.1<\/td><td class=\"oth\">111.1<\/td><\/tr>\n<tr><td class=\"num\">142.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Imipramine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-49-7\/Imipramine\" target=\"_blank\" rel=\"noopener\">Imipramine<\/a><\/td><td class=\"oth\">6.51<\/td><td class=\"oth\">25<\/td><td class=\"oth\">281.1<\/td><td class=\"oth\">86.2<\/td><td class=\"oth\">58.1<\/td><\/tr>\n<tr><td class=\"num\">143.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Paroxetine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/61869-08-7\/Paroxetine\" target=\"_blank\" rel=\"noopener\">Paroxetine<\/a><\/td><td class=\"oth\">6.51<\/td><td class=\"oth\">25<\/td><td class=\"oth\">330.2<\/td><td class=\"oth\">192.2<\/td><td class=\"oth\">70.1<\/td><\/tr>\n<tr><td class=\"num\">144.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Loxapine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1977-10-2\/Loxapine\" target=\"_blank\" rel=\"noopener\">Loxapine<\/a><\/td><td class=\"oth\">6.52<\/td><td class=\"oth\">25<\/td><td class=\"oth\">328.1<\/td><td class=\"oth\">271.1<\/td><td class=\"oth\">193.0<\/td><\/tr>\n<tr><td class=\"num\">145.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Maprotiline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/10262-69-8\/Maprotiline\" target=\"_blank\" rel=\"noopener\">Maprotiline<\/a><\/td><td class=\"oth\">6.52<\/td><td class=\"oth\">25<\/td><td class=\"oth\">278.1<\/td><td class=\"oth\">250.2<\/td><td class=\"oth\">191.0<\/td><\/tr>\n<tr><td class=\"num\">146.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Duloxetine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/136434-34-9\/Duloxetine\" target=\"_blank\" rel=\"noopener\">Duloxetine<\/a><\/td><td class=\"oth\">6.52<\/td><td class=\"oth\">25<\/td><td class=\"oth\">298.1<\/td><td class=\"oth\">154.1<\/td><td class=\"oth\">188.2<\/td><\/tr>\n<tr><td class=\"num\">147.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Metaxalone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1665-48-1\/Metaxalone\" target=\"_blank\" rel=\"noopener\">Metaxalone<\/a><\/td><td class=\"oth\">6.52<\/td><td class=\"oth\">25<\/td><td class=\"oth\">222.1<\/td><td class=\"oth\">161.1<\/td><td class=\"oth\">77.1<\/td><\/tr>\n<tr><td class=\"num\">148.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carbamazepine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-46-4\/Carbamazepine\" target=\"_blank\" rel=\"noopener\">Carbamazepine<\/a><\/td><td class=\"oth\">6.55<\/td><td class=\"oth\">10<\/td><td class=\"oth\">237.1<\/td><td class=\"oth\">194.1<\/td><td class=\"oth\">165.0<\/td><\/tr>\n<tr><td class=\"num\">149.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cyclobenzaprine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/303-53-7\/Cyclobenzaprine\" target=\"_blank\" rel=\"noopener\">Cyclobenzaprine<\/a><\/td><td class=\"oth\">6.56<\/td><td class=\"oth\">25<\/td><td class=\"oth\">276.2<\/td><td class=\"oth\">215.0<\/td><td class=\"oth\">189.0<\/td><\/tr>\n<tr><td class=\"num\">150.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for EDDP\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/30223-73-5\/EDDP\" target=\"_blank\" rel=\"noopener\">EDDP<\/a><\/td><td class=\"oth\">6.57<\/td><td class=\"oth\">25<\/td><td class=\"oth\">278.2<\/td><td class=\"oth\">234.3<\/td><td class=\"oth\">249.2<\/td><\/tr>\n<tr><td class=\"num\">151.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nortriptyline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72-69-5\/Nortriptyline\" target=\"_blank\" rel=\"noopener\">Nortriptyline<\/a><\/td><td class=\"oth\">6.58<\/td><td class=\"oth\">25<\/td><td class=\"oth\">264.1<\/td><td class=\"oth\">91.1<\/td><td class=\"oth\">115.2<\/td><\/tr>\n<tr><td class=\"num\">152.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mitragynine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/4098-40-2\/Mitragynine\" target=\"_blank\" rel=\"noopener\">Mitragynine<\/a><\/td><td class=\"oth\">6.59<\/td><td class=\"oth\">25<\/td><td class=\"oth\">399.3<\/td><td class=\"oth\">174.2<\/td><td class=\"oth\">159.0<\/td><\/tr>\n<tr><td class=\"num\">153.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Eslicarbazepine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/236395-14-5\/Eslicarbazepine\" target=\"_blank\" rel=\"noopener\">Eslicarbazepine<\/a><\/td><td class=\"oth\">6.60<\/td><td class=\"oth\">25<\/td><td class=\"oth\">297.2<\/td><td class=\"oth\">194.0<\/td><td class=\"oth\">237.1<\/td><\/tr>\n<tr><td class=\"num\">154.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Amitriptyline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-48-6\/Amitriptyline\" target=\"_blank\" rel=\"noopener\">Amitriptyline<\/a><\/td><td class=\"oth\">6.65<\/td><td class=\"oth\">25<\/td><td class=\"oth\">278.1<\/td><td class=\"oth\">91.1<\/td><td class=\"oth\">202.1<\/td><\/tr>\n<tr><td class=\"num\">155.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-Hydroxymidazolam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59468-90-5\/\u03b1-Hydroxymidazolam\" target=\"_blank\" rel=\"noopener\">\u03b1-Hydroxymidazolam<\/a><\/td><td class=\"oth\">6.70<\/td><td class=\"oth\">25<\/td><td class=\"oth\">342.2<\/td><td class=\"oth\">324.1<\/td><td class=\"oth\">202.9<\/td><\/tr>\n<tr><td class=\"num\">156.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Trimipramine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/739-71-9\/Trimipramine\" target=\"_blank\" rel=\"noopener\">Trimipramine<\/a><\/td><td class=\"oth\">6.75<\/td><td class=\"oth\">25<\/td><td class=\"oth\">295.2<\/td><td class=\"oth\">100.2<\/td><td class=\"oth\">58.2<\/td><\/tr>\n<tr><td class=\"num\">157.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Desmethylflunitrazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2558-30-7\/N-Desmethylflunitrazepam\" target=\"_blank\" rel=\"noopener\">N-Desmethylflunitrazepam<\/a><\/td><td class=\"oth\">6.80<\/td><td class=\"oth\">25<\/td><td class=\"oth\">300.1<\/td><td class=\"oth\">254.1<\/td><td class=\"oth\">198.1<\/td><\/tr>\n<tr><td class=\"num\">158.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Lorazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/846-49-1\/Lorazepam\" target=\"_blank\" rel=\"noopener\">Lorazepam<\/a><\/td><td class=\"oth\">6.82<\/td><td class=\"oth\">25<\/td><td class=\"oth\">321.1<\/td><td class=\"oth\">275.0<\/td><td class=\"oth\">229.0<\/td><\/tr>\n<tr><td class=\"num\">159.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mesoridazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5588-33-0\/Mesoridazine\" target=\"_blank\" rel=\"noopener\">Mesoridazine<\/a><\/td><td class=\"oth\">6.83<\/td><td class=\"oth\">25<\/td><td class=\"oth\">387.2<\/td><td class=\"oth\">126.1<\/td><td class=\"oth\">98.2<\/td><\/tr>\n<tr><td class=\"num\">160.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tiagabine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/115103-54-3\/Tiagabine\" target=\"_blank\" rel=\"noopener\">Tiagabine<\/a><\/td><td class=\"oth\">6.89<\/td><td class=\"oth\">25<\/td><td class=\"oth\">376.2<\/td><td class=\"oth\">246.8<\/td><td class=\"oth\">111.1<\/td><\/tr>\n<tr><td class=\"num\">161.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ketorolac\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/74103-06-3\/Ketorolac\" target=\"_blank\" rel=\"noopener\">Ketorolac<\/a><\/td><td class=\"oth\">6.90<\/td><td class=\"oth\">25<\/td><td class=\"oth\">256.1<\/td><td class=\"oth\">104.9<\/td><td class=\"oth\">77.0<\/td><\/tr>\n<tr><td class=\"num\">162.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorpromazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-53-3\/Chlorpromazine\" target=\"_blank\" rel=\"noopener\">Chlorpromazine<\/a><\/td><td class=\"oth\">6.91<\/td><td class=\"oth\">25<\/td><td class=\"oth\">320.1<\/td><td class=\"oth\">58.1<\/td><td class=\"oth\">86.1<\/td><\/tr>\n<tr><td class=\"num\">163.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Loxoprofen*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/68767-14-6\/Loxoprofen\" target=\"_blank\" rel=\"noopener\">Loxoprofen*<\/a><\/td><td class=\"oth\">6.93<\/td><td class=\"oth\">200<\/td><td class=\"oth\">245.0<\/td><td class=\"oth\">83.2<\/td><td class=\"oth\">80.9<\/td><\/tr>\n<tr><td class=\"num\">164.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Clomipramine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/303-49-1\/Clomipramine\" target=\"_blank\" rel=\"noopener\">Clomipramine<\/a><\/td><td class=\"oth\">6.95<\/td><td class=\"oth\">25<\/td><td class=\"oth\">315.3<\/td><td class=\"oth\">86.0<\/td><td class=\"oth\">58.0<\/td><\/tr>\n<tr><td class=\"num\">165.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Oxazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/604-75-1\/Oxazepam\" target=\"_blank\" rel=\"noopener\">Oxazepam<\/a><\/td><td class=\"oth\">6.96<\/td><td class=\"oth\">25<\/td><td class=\"oth\">287.1<\/td><td class=\"oth\">241.2<\/td><td class=\"oth\">268.8<\/td><\/tr>\n<tr><td class=\"num\">166.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methadone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-99-3\/Methadone\" target=\"_blank\" rel=\"noopener\">Methadone<\/a><\/td><td class=\"oth\">6.98<\/td><td class=\"oth\">25<\/td><td class=\"oth\">310.2<\/td><td class=\"oth\">264.9<\/td><td class=\"oth\">105.1<\/td><\/tr>\n<tr><td class=\"num\">167.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Sertraline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/79617-96-2\/Sertraline\" target=\"_blank\" rel=\"noopener\">Sertraline<\/a><\/td><td class=\"oth\">6.98<\/td><td class=\"oth\">25<\/td><td class=\"oth\">306.2<\/td><td class=\"oth\">158.9<\/td><td class=\"oth\">275.1<\/td><\/tr>\n<tr><td class=\"num\">168.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dehydro aripiprazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/129722-25-4\/Dehydro aripiprazole\" target=\"_blank\" rel=\"noopener\">Dehydro aripiprazole<\/a><\/td><td class=\"oth\">7.01<\/td><td class=\"oth\">25<\/td><td class=\"oth\">446.2<\/td><td class=\"oth\">285.0<\/td><td class=\"oth\">98.1<\/td><\/tr>\n<tr><td class=\"num\">169.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Clonazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1622-61-3\/Clonazepam\" target=\"_blank\" rel=\"noopener\">Clonazepam<\/a><\/td><td class=\"oth\">7.01<\/td><td class=\"oth\">25<\/td><td class=\"oth\">316.1<\/td><td class=\"oth\">270.0<\/td><td class=\"oth\">214.1<\/td><\/tr>\n<tr><td class=\"num\">170.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nitrazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/146-22-5\/Nitrazepam\" target=\"_blank\" rel=\"noopener\">Nitrazepam<\/a><\/td><td class=\"oth\">7.01<\/td><td class=\"oth\">25<\/td><td class=\"oth\">282.1<\/td><td class=\"oth\">235.9<\/td><td class=\"oth\">180.1<\/td><\/tr>\n<tr><td class=\"num\">171.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Lornoxicam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/70374-39-9\/Lornoxicam\" target=\"_blank\" rel=\"noopener\">Lornoxicam<\/a><\/td><td class=\"oth\">7.02<\/td><td class=\"oth\">100<\/td><td class=\"oth\">373.1<\/td><td class=\"oth\">121.1<\/td><td class=\"oth\">95.0<\/td><\/tr>\n<tr><td class=\"num\">172.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 25I-NBOMe\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/919797-19-6\/25I-NBOMe\" target=\"_blank\" rel=\"noopener\">25I-NBOMe<\/a><\/td><td class=\"oth\">7.05<\/td><td class=\"oth\">25<\/td><td class=\"oth\">428.1<\/td><td class=\"oth\">121.2<\/td><td class=\"oth\">91.1<\/td><\/tr>\n<tr><td class=\"num\">173.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Salsalate*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/552-94-3\/Salsalate\" target=\"_blank\" rel=\"noopener\">Salsalate*<\/a><\/td><td class=\"oth\">7.05<\/td><td class=\"oth\">100<\/td><td class=\"oth\">256.8<\/td><td class=\"oth\">136.8<\/td><td class=\"oth\">92.9<\/td><\/tr>\n<tr><td class=\"num\">174.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Desalkylflurazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2886-65-9\/Desalkylflurazepam\" target=\"_blank\" rel=\"noopener\">Desalkylflurazepam<\/a><\/td><td class=\"oth\">7.09<\/td><td class=\"oth\">25<\/td><td class=\"oth\">289.0<\/td><td class=\"oth\">140.1<\/td><td class=\"oth\">104.0<\/td><\/tr>\n<tr><td class=\"num\">175.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tolmetin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/26171-23-3\/Tolmetin\" target=\"_blank\" rel=\"noopener\">Tolmetin<\/a><\/td><td class=\"oth\">7.10<\/td><td class=\"oth\">25<\/td><td class=\"oth\">258.1<\/td><td class=\"oth\">119.1<\/td><td class=\"oth\">91.0<\/td><\/tr>\n<tr><td class=\"num\">176.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-Hydroxytriazolam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/37115-45-0\/\u03b1-Hydroxytriazolam\" target=\"_blank\" rel=\"noopener\">\u03b1-Hydroxytriazolam<\/a><\/td><td class=\"oth\">7.12<\/td><td class=\"oth\">25<\/td><td class=\"oth\">359.1<\/td><td class=\"oth\">330.9<\/td><td class=\"oth\">175.9<\/td><\/tr>\n<tr><td class=\"num\">177.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluphenazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/69-23-8\/Fluphenazine\" target=\"_blank\" rel=\"noopener\">Fluphenazine<\/a><\/td><td class=\"oth\">7.16<\/td><td class=\"oth\">25<\/td><td class=\"oth\">438.3<\/td><td class=\"oth\">171.1<\/td><td class=\"oth\">143.2<\/td><\/tr>\n<tr><td class=\"num\">178.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Hydroxyethylflurazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/20971-53-3\/2-Hydroxyethylflurazepam\" target=\"_blank\" rel=\"noopener\">2-Hydroxyethylflurazepam<\/a><\/td><td class=\"oth\">7.16<\/td><td class=\"oth\">25<\/td><td class=\"oth\">333.1<\/td><td class=\"oth\">211.1<\/td><td class=\"oth\">109.0<\/td><\/tr>\n<tr><td class=\"num\">179.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ketoprofen*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/22071-15-4\/Ketoprofen\" target=\"_blank\" rel=\"noopener\">Ketoprofen*<\/a><\/td><td class=\"oth\">7.17<\/td><td class=\"oth\">100<\/td><td class=\"oth\">253.0<\/td><td class=\"oth\">209.0<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">180.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Naproxen*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/22204-53-1\/Naproxen\" target=\"_blank\" rel=\"noopener\">Naproxen*<\/a><\/td><td class=\"oth\">7.17<\/td><td class=\"oth\">200<\/td><td class=\"oth\">229.0<\/td><td class=\"oth\">168.9<\/td><td class=\"oth\">184.9<\/td><\/tr>\n<tr><td class=\"num\">181.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for EMDP\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/102177-18-4\/EMDP\" target=\"_blank\" rel=\"noopener\">EMDP<\/a><\/td><td class=\"oth\">7.19<\/td><td class=\"oth\">25<\/td><td class=\"oth\">264.2<\/td><td class=\"oth\">235.2<\/td><td class=\"oth\">220.3<\/td><\/tr>\n<tr><td class=\"num\">182.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aripiprazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/129722-12-9\/Aripiprazole\" target=\"_blank\" rel=\"noopener\">Aripiprazole<\/a><\/td><td class=\"oth\">7.20<\/td><td class=\"oth\">25<\/td><td class=\"oth\">448.2<\/td><td class=\"oth\">285.0<\/td><td class=\"oth\">176.1<\/td><\/tr>\n<tr><td class=\"num\">183.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perphenazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/58-39-9\/Perphenazine\" target=\"_blank\" rel=\"noopener\">Perphenazine<\/a><\/td><td class=\"oth\">7.22<\/td><td class=\"oth\">25<\/td><td class=\"oth\">404.2<\/td><td class=\"oth\">171.1<\/td><td class=\"oth\">143.2<\/td><\/tr>\n<tr><td class=\"num\">184.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Etoricoxib\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/202409-33-4\/Etoricoxib\" target=\"_blank\" rel=\"noopener\">Etoricoxib<\/a><\/td><td class=\"oth\">7.24<\/td><td class=\"oth\">25<\/td><td class=\"oth\">359.2<\/td><td class=\"oth\">280.0<\/td><td class=\"oth\">279.2<\/td><\/tr>\n<tr><td class=\"num\">185.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methaqualone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72-44-6\/Methaqualone\" target=\"_blank\" rel=\"noopener\">Methaqualone<\/a><\/td><td class=\"oth\">7.24<\/td><td class=\"oth\">25<\/td><td class=\"oth\">251.1<\/td><td class=\"oth\">91.1<\/td><td class=\"oth\">132.2<\/td><\/tr>\n<tr><td class=\"num\">186.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-Hydroxyalprazolam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/37115-43-8\/\u03b1-Hydroxyalprazolam\" target=\"_blank\" rel=\"noopener\">\u03b1-Hydroxyalprazolam<\/a><\/td><td class=\"oth\">7.25<\/td><td class=\"oth\">25<\/td><td class=\"oth\">325.1<\/td><td class=\"oth\">297.0<\/td><td class=\"oth\">216.2<\/td><\/tr>\n<tr><td class=\"num\">187.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Trifluoperazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/117-89-5\/Trifluoperazine\" target=\"_blank\" rel=\"noopener\">Trifluoperazine<\/a><\/td><td class=\"oth\">7.28<\/td><td class=\"oth\">25<\/td><td class=\"oth\">408.2<\/td><td class=\"oth\">141.2<\/td><td class=\"oth\">113.1<\/td><\/tr>\n<tr><td class=\"num\">188.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Piroxicam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/36322-90-4\/Piroxicam\" target=\"_blank\" rel=\"noopener\">Piroxicam<\/a><\/td><td class=\"oth\">7.34<\/td><td class=\"oth\">25<\/td><td class=\"oth\">332.1<\/td><td class=\"oth\">95.2<\/td><td class=\"oth\">78.1<\/td><\/tr>\n<tr><td class=\"num\">189.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ibuprofen*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/15687-27-1\/Ibuprofen\" target=\"_blank\" rel=\"noopener\">Ibuprofen*<\/a><\/td><td class=\"oth\">7.34<\/td><td class=\"oth\">200<\/td><td class=\"oth\">205.0<\/td><td class=\"oth\">160.9<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">190.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Prochlorperazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/58-38-8\/Prochlorperazine\" target=\"_blank\" rel=\"noopener\">Prochlorperazine<\/a><\/td><td class=\"oth\">7.36<\/td><td class=\"oth\">25<\/td><td class=\"oth\">374.1<\/td><td class=\"oth\">141.0<\/td><td class=\"oth\">113.1<\/td><\/tr>\n<tr><td class=\"num\">191.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Etodolac*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/41340-25-4\/Etodolac\" target=\"_blank\" rel=\"noopener\">Etodolac*<\/a><\/td><td class=\"oth\">7.36<\/td><td class=\"oth\">50<\/td><td class=\"oth\">286.0<\/td><td class=\"oth\">241.9<\/td><td class=\"oth\">212.0<\/td><\/tr>\n<tr><td class=\"num\">192.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nordiazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1088-11-5\/Nordiazepam\" target=\"_blank\" rel=\"noopener\">Nordiazepam<\/a><\/td><td class=\"oth\">7.37<\/td><td class=\"oth\">25<\/td><td class=\"oth\">271.0<\/td><td class=\"oth\">139.9<\/td><td class=\"oth\">208.0<\/td><\/tr>\n<tr><td class=\"num\">193.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51753-57-2\/Phenazepam\" target=\"_blank\" rel=\"noopener\">Phenazepam<\/a><\/td><td class=\"oth\">7.39<\/td><td class=\"oth\">25<\/td><td class=\"oth\">349.1<\/td><td class=\"oth\">206.2<\/td><td class=\"oth\">179.0<\/td><\/tr>\n<tr><td class=\"num\">194.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenoprofen*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/29679-58-1\/Fenoprofen\" target=\"_blank\" rel=\"noopener\">Fenoprofen*<\/a><\/td><td class=\"oth\">7.40<\/td><td class=\"oth\">200<\/td><td class=\"oth\">240.9<\/td><td class=\"oth\">92.8<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">195.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Zaleplon\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/151319-34-5\/Zaleplon\" target=\"_blank\" rel=\"noopener\">Zaleplon<\/a><\/td><td class=\"oth\">7.43<\/td><td class=\"oth\">25<\/td><td class=\"oth\">306.1<\/td><td class=\"oth\">264.0<\/td><td class=\"oth\">236.0<\/td><\/tr>\n<tr><td class=\"num\">196.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Clobazam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/22316-47-8\/Clobazam\" target=\"_blank\" rel=\"noopener\">Clobazam<\/a><\/td><td class=\"oth\">7.43<\/td><td class=\"oth\">25<\/td><td class=\"oth\">301.0<\/td><td class=\"oth\">259.1<\/td><td class=\"oth\">224.0<\/td><\/tr>\n<tr><td class=\"num\">197.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flurbiprofen*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5104-49-4\/Flurbiprofen\" target=\"_blank\" rel=\"noopener\">Flurbiprofen*<\/a><\/td><td class=\"oth\">7.48<\/td><td class=\"oth\">200<\/td><td class=\"oth\">243.0<\/td><td class=\"oth\">199.0<\/td><td class=\"oth\">196.8<\/td><\/tr>\n<tr><td class=\"num\">198.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Thiothixene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5591-45-7\/Thiothixene\" target=\"_blank\" rel=\"noopener\">Thiothixene<\/a><\/td><td class=\"oth\">7.50<\/td><td class=\"oth\">25<\/td><td class=\"oth\">444.2<\/td><td class=\"oth\">221.2<\/td><td class=\"oth\">235.0<\/td><\/tr>\n<tr><td class=\"num\">199.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flunitrazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1622-62-4\/Flunitrazepam\" target=\"_blank\" rel=\"noopener\">Flunitrazepam<\/a><\/td><td class=\"oth\">7.55<\/td><td class=\"oth\">25<\/td><td class=\"oth\">314.2<\/td><td class=\"oth\">267.9<\/td><td class=\"oth\">239.1<\/td><\/tr>\n<tr><td class=\"num\">200.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Meloxicam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/71125-38-7\/Meloxicam\" target=\"_blank\" rel=\"noopener\">Meloxicam<\/a><\/td><td class=\"oth\">7.55<\/td><td class=\"oth\">25<\/td><td class=\"oth\">352.1<\/td><td class=\"oth\">115.0<\/td><td class=\"oth\">141.0<\/td><\/tr>\n<tr><td class=\"num\">201.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Triazolam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/28911-01-5\/Triazolam\" target=\"_blank\" rel=\"noopener\">Triazolam<\/a><\/td><td class=\"oth\">7.58<\/td><td class=\"oth\">25<\/td><td class=\"oth\">343.1<\/td><td class=\"oth\">307.9<\/td><td class=\"oth\">315.0<\/td><\/tr>\n<tr><td class=\"num\">202.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Estazolam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/29975-16-4\/Estazolam\" target=\"_blank\" rel=\"noopener\">Estazolam<\/a><\/td><td class=\"oth\">7.58<\/td><td class=\"oth\">25<\/td><td class=\"oth\">295.1<\/td><td class=\"oth\">266.9<\/td><td class=\"oth\">205.1<\/td><\/tr>\n<tr><td class=\"num\">203.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Celecoxib\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/169590-42-5\/Celecoxib\" target=\"_blank\" rel=\"noopener\">Celecoxib<\/a><\/td><td class=\"oth\">7.60<\/td><td class=\"oth\">25<\/td><td class=\"oth\">382.2<\/td><td class=\"oth\">362.0<\/td><td class=\"oth\">300.1<\/td><\/tr>\n<tr><td class=\"num\">204.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Parecoxib\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/198470-84-7\/Parecoxib\" target=\"_blank\" rel=\"noopener\">Parecoxib<\/a><\/td><td class=\"oth\">7.60<\/td><td class=\"oth\">25<\/td><td class=\"oth\">371.2<\/td><td class=\"oth\">234.0<\/td><td class=\"oth\">165.1<\/td><\/tr>\n<tr><td class=\"num\">205.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Temazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/846-50-4\/Temazepam\" target=\"_blank\" rel=\"noopener\">Temazepam<\/a><\/td><td class=\"oth\">7.61<\/td><td class=\"oth\">25<\/td><td class=\"oth\">301.1<\/td><td class=\"oth\">255.1<\/td><td class=\"oth\">282.9<\/td><\/tr>\n<tr><td class=\"num\">206.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Sulindac\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/38194-50-2\/Sulindac\" target=\"_blank\" rel=\"noopener\">Sulindac<\/a><\/td><td class=\"oth\">7.70<\/td><td class=\"oth\">25<\/td><td class=\"oth\">357.2<\/td><td class=\"oth\">233.1<\/td><td class=\"oth\">248.0<\/td><\/tr>\n<tr><td class=\"num\">207.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Alprazolam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/28981-97-7\/Alprazolam\" target=\"_blank\" rel=\"noopener\">Alprazolam<\/a><\/td><td class=\"oth\">7.72<\/td><td class=\"oth\">25<\/td><td class=\"oth\">309.1<\/td><td class=\"oth\">280.9<\/td><td class=\"oth\">204.9<\/td><\/tr>\n<tr><td class=\"num\">208.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flufenamic acid*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/530-78-9\/Flufenamic acid\" target=\"_blank\" rel=\"noopener\">Flufenamic acid*<\/a><\/td><td class=\"oth\">7.75<\/td><td class=\"oth\">50<\/td><td class=\"oth\">279.9<\/td><td class=\"oth\">236.1<\/td><td class=\"oth\">176.2<\/td><\/tr>\n<tr><td class=\"num\">209.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Thioridazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-52-2\/Thioridazine\" target=\"_blank\" rel=\"noopener\">Thioridazine<\/a><\/td><td class=\"oth\">7.76<\/td><td class=\"oth\">25<\/td><td class=\"oth\">371.2<\/td><td class=\"oth\">126.1<\/td><td class=\"oth\">98.1<\/td><\/tr>\n<tr><td class=\"num\">210.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diclofenac*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/15307-86-5\/Diclofenac\" target=\"_blank\" rel=\"noopener\">Diclofenac*<\/a><\/td><td class=\"oth\">7.78<\/td><td class=\"oth\">100<\/td><td class=\"oth\">293.9<\/td><td class=\"oth\">249.8<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">211.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nabumetone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/42924-53-8\/Nabumetone\" target=\"_blank\" rel=\"noopener\">Nabumetone<\/a><\/td><td class=\"oth\">7.80<\/td><td class=\"oth\">25<\/td><td class=\"oth\">229.1<\/td><td class=\"oth\">171.1<\/td><td class=\"oth\">128.1<\/td><\/tr>\n<tr><td class=\"num\">212.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Oxaprozin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/21256-18-8\/Oxaprozin\" target=\"_blank\" rel=\"noopener\">Oxaprozin<\/a><\/td><td class=\"oth\">7.87<\/td><td class=\"oth\">25<\/td><td class=\"oth\">294.1<\/td><td class=\"oth\">103.0<\/td><td class=\"oth\">234.2<\/td><\/tr>\n<tr><td class=\"num\">213.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for HU-211\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/112924-45-5\/HU-211\" target=\"_blank\" rel=\"noopener\">HU-211<\/a><\/td><td class=\"oth\">8.03<\/td><td class=\"oth\">25<\/td><td class=\"oth\">387.3<\/td><td class=\"oth\">155.9<\/td><td class=\"oth\">128.1<\/td><\/tr>\n<tr><td class=\"num\">214.<\/td><td class=\"cmpd\">JWH\u2010200<\/td><td class=\"oth\">8.04<\/td><td class=\"oth\">25<\/td><td class=\"oth\">385.3<\/td><td class=\"oth\">155.0<\/td><td class=\"oth\">127.1<\/td><\/tr>\n<tr><td class=\"num\">215.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/439-14-5\/Diazepam\" target=\"_blank\" rel=\"noopener\">Diazepam<\/a><\/td><td class=\"oth\">8.04<\/td><td class=\"oth\">25<\/td><td class=\"oth\">285.1<\/td><td class=\"oth\">192.9<\/td><td class=\"oth\">153.9<\/td><\/tr>\n<tr><td class=\"num\">216.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mefenamic acid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/61-68-7\/Mefenamic acid\" target=\"_blank\" rel=\"noopener\">Mefenamic acid<\/a><\/td><td class=\"oth\">8.04<\/td><td class=\"oth\">25<\/td><td class=\"oth\">242.1<\/td><td class=\"oth\">224.1<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">217.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tolfenamic acid*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13710-19-5\/Tolfenamic acid\" target=\"_blank\" rel=\"noopener\">Tolfenamic acid*<\/a><\/td><td class=\"oth\">8.17<\/td><td class=\"oth\">50<\/td><td class=\"oth\">259.9<\/td><td class=\"oth\">215.8<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">218.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Meclofenamic acid*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/644-62-2\/Meclofenamic acid\" target=\"_blank\" rel=\"noopener\">Meclofenamic acid*<\/a><\/td><td class=\"oth\">8.18<\/td><td class=\"oth\">200<\/td><td class=\"oth\">293.9<\/td><td class=\"oth\">257.8<\/td><td class=\"oth\">177.7<\/td><\/tr>\n<tr><td class=\"num\">219.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (+\/-)-CP 47,497*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/70434-82-1\/(+_-)-CP 47,497\" target=\"_blank\" rel=\"noopener\">(+\/-)-CP 47,497*<\/a><\/td><td class=\"oth\">8.27<\/td><td class=\"oth\">200<\/td><td class=\"oth\">317.1<\/td><td class=\"oth\">245.1<\/td><td class=\"oth\">159.0<\/td><\/tr>\n<tr><td class=\"num\">220.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Indomethacin*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53-86-1\/Indomethacin\" target=\"_blank\" rel=\"noopener\">Indomethacin*<\/a><\/td><td class=\"oth\">8.29<\/td><td class=\"oth\">50<\/td><td class=\"oth\">356.0<\/td><td class=\"oth\">311.8<\/td><td class=\"oth\">296.9<\/td><\/tr>\n<tr><td class=\"num\">221.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perampanel\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/380917-97-5\/Perampanel\" target=\"_blank\" rel=\"noopener\">Perampanel<\/a><\/td><td class=\"oth\">8.32<\/td><td class=\"oth\">25<\/td><td class=\"oth\">350.2<\/td><td class=\"oth\">219.1<\/td><td class=\"oth\">247.1<\/td><\/tr>\n<tr><td class=\"num\">222.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (+\/-)-CP 47,497 C8 homologue*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/70434-92-3\/(+_-)-CP 47,497 C8 homologue\" target=\"_blank\" rel=\"noopener\">(+\/-)-CP 47,497 C8 homologue*<\/a><\/td><td class=\"oth\">8.42<\/td><td class=\"oth\">200<\/td><td class=\"oth\">331.1<\/td><td class=\"oth\">259.0<\/td><td class=\"oth\">159.1<\/td><\/tr>\n<tr><td class=\"num\">223.<\/td><td class=\"cmpd\">11-Nor-9-carboxy-delta-9-THC*<\/td><td class=\"oth\">8.44<\/td><td class=\"oth\">25<\/td><td class=\"oth\">343.0<\/td><td class=\"oth\">298.9<\/td><td class=\"oth\">244.8<\/td><\/tr>\n<tr><td class=\"num\">224.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Prazepam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2955-38-6\/Prazepam\" target=\"_blank\" rel=\"noopener\">Prazepam<\/a><\/td><td class=\"oth\">8.51<\/td><td class=\"oth\">25<\/td><td class=\"oth\">325.2<\/td><td class=\"oth\">271.0<\/td><td class=\"oth\">139.9<\/td><\/tr>\n<tr><td class=\"num\">225.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for XLR-11\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1364933-54-9\/XLR-11\" target=\"_blank\" rel=\"noopener\">XLR-11<\/a><\/td><td class=\"oth\">8.60<\/td><td class=\"oth\">25<\/td><td class=\"oth\">330.3<\/td><td class=\"oth\">125.2<\/td><td class=\"oth\">144.0<\/td><\/tr>\n<tr><td class=\"num\">226.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03949-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1972-08-3\/\u03949-THC\" target=\"_blank\" rel=\"noopener\">\u03949-THC<\/a><\/td><td class=\"oth\">8.76<\/td><td class=\"oth\">25<\/td><td class=\"oth\">315.2<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.2<\/td><\/tr>\n<tr><td class=\"num\">227.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for UR-144\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1199943-44-6\/UR-144\" target=\"_blank\" rel=\"noopener\">UR-144<\/a><\/td><td class=\"oth\">8.78<\/td><td class=\"oth\">25<\/td><td class=\"oth\">312.3<\/td><td class=\"oth\">125.1<\/td><td class=\"oth\">214.1<\/td><\/tr>\n<tr><td class=\"num\">228.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for JWH-250\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/864445-43-2\/JWH-250\" target=\"_blank\" rel=\"noopener\">JWH-250<\/a><\/td><td class=\"oth\">8.96<\/td><td class=\"oth\">25<\/td><td class=\"oth\">336.3<\/td><td class=\"oth\">120.9<\/td><td class=\"oth\">91.1<\/td><\/tr>\n<tr><td class=\"num\">229.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for THCA-A*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/23978-85-0\/THCA-A\" target=\"_blank\" rel=\"noopener\">THCA-A*<\/a><\/td><td class=\"oth\">9.12<\/td><td class=\"oth\">25<\/td><td class=\"oth\">357.1<\/td><td class=\"oth\">312.9<\/td><td class=\"oth\">245.0<\/td><\/tr>\n<tr><td class=\"num\">230.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for JWH-073\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/208897-48-8\/JWH-073\" target=\"_blank\" rel=\"noopener\">JWH-073<\/a><\/td><td class=\"oth\">9.21<\/td><td class=\"oth\">25<\/td><td class=\"oth\">328.2<\/td><td class=\"oth\">155.0<\/td><td class=\"oth\">127.1<\/td><\/tr>\n<tr><td class=\"num\">231.<\/td><td class=\"cmpd\">JWH\u2010018<\/td><td class=\"oth\">9.35<\/td><td class=\"oth\">25<\/td><td class=\"oth\">342.3<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">155.1<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">*Analyzed using negative polarity.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor Biphenyl  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9309A12\" rel=\"noopener\">cat.# 9309A12<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>Raptor Biphenyl EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9309A0252\" rel=\"noopener\">cat.# 9309A0252<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>30 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Water<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water + 0.1% formic acid + 2 mM ammonium formate <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td> Methanol + 0.1% formic acid + 2 mM ammonium formate <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.6<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>9.00<\/td><td>0.6<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>10.00<\/td><td>0.6<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>10.01<\/td><td>0.6<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>12.00<\/td><td>0.6<\/td><td>95<\/td><td>5<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+\/ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>Scheduled MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>UHPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>1. Positive and negative polarity data were collected simultaneously from a single injection. <br \/>2. Ibuprofen, fosphenytoin, and topiramate degrade quickly in solution.<br \/>3. Levorphanol and dextrorphan are enantiomers and are not resolved.<br \/>4. Escitalopram is a pure enantiomer and citalopram is a racemic mixture of both enantiomers.  These compounds are not resolved.<br \/>5. DMAA consists of 4 stereoisomers, 2 of which are partially resolved.<br \/>6. Doxepin and desmethylydoxepin consist of a mixture of <i>cis\/trans<\/i> isomers.  The isomers are fully resolved and the retention time identifies the main isomer component.<br \/>7. Lornoxicam, meloxicam, etodolac, oxaprozin, indomethacin, and mefenamic acid can be detected by positive or negative polarity.  The polarity chosen in this chromatogram provides optimal response.<br \/><\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9309A0252<\/li><li>9309A12<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0621.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Comme le montre cette application, la colonne Restek Raptor Biphenyl est id\u00e9ale pour le d\u00e9veloppement de m\u00e9thodes de screening toxicologique rapides et efficaces. Gr\u00e2ce \u00e0 sa r\u00e9tention tr\u00e8s \u00e9lev\u00e9e et sa s\u00e9lectivit\u00e9 unique, 231 compos\u00e9s et m\u00e9tabolites \u2013 dont plus de 40 isobares \u2013 de diff\u00e9rentes familles peuvent \u00eatre analys\u00e9s en seulement 10 minutes!<\/p>\n","protected":false},"author":11,"featured_media":70275,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[462,7],"tags":[],"industries-application":[2203],"post-badge":[],"resource-type":[],"product-library":[2391],"resource-technique":[2318,2362],"ppma_author":[414],"class_list":["post-43378","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-fr","category-articles","industries-application-toxicologie-clinique","product-library-lc-columns","resource-technique-chromatographie-en-phase-liquide","resource-technique-ms-ms-fr"],"acf":[],"taxonomy_info":{"category":[{"value":462,"label":"Articles"},{"value":7,"label":"Articles"}],"industries-application":[{"value":2203,"label":"Toxicologie Clinique"}],"product-library":[{"value":2391,"label":"LC Columns"}],"resource-technique":[{"value":2318,"label":"Chromatographie en phase liquide"},{"value":2362,"label":"MS\/MS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-CFSS2310-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":462,"name":"Articles","slug":"articles-fr","term_group":0,"term_taxonomy_id":462,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":462,"category_count":510,"category_description":"","cat_name":"Articles","category_nicename":"articles-fr","category_parent":0},{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":7,"category_count":510,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43378","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=43378"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43378\/revisions"}],"predecessor-version":[{"id":85650,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43378\/revisions\/85650"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/70275"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=43378"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=43378"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=43378"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=43378"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=43378"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=43378"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=43378"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=43378"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=43378"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}