{"id":43461,"date":"2025-10-03T21:13:17","date_gmt":"2025-10-03T21:13:17","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/pfas-analysis-by-iso-21675-2019-for-water\/"},"modified":"2026-08-07T14:37:25","modified_gmt":"2026-08-07T14:37:25","slug":"pfas-analysis-by-iso-21675-2019-for-water","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/articles\/evar4300\/pfas-analysis-by-iso-21675-2019-for-water","title":{"rendered":"PFAS Analysis by ISO 21675:2019 for Water"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li><strong>Sample Matrix:<\/strong> water containing &lt;2 g\/L solids<\/li>\n\n\n\n<li><strong>Sample Preparation: <\/strong>WAX solid-phase extraction<\/li>\n\n\n\n<li><strong>Detection Technique: <\/strong>LC-MS\/MS<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Determination of perfluoroalkyl and polyfluoroalkyl substances (PFAS) in water\u2014Method using solid phase extraction and liquid chromatography-tandem mass spectrometry (LC-MS\/MS)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ISO 21675:2019 is used for the analysis of 30 PFAS in water containing &lt;2 g\/L solids. It is not available from Restek but may be purchased from other sources. The full analyte list and recommended products for ISO 21675:2019 are provided below. In addition, you can register and directly&nbsp;<a href=\"https:\/\/explore.restek.com\/PFAS-Guides\" target=\"_blank\" rel=\"noreferrer noopener\">compare analyte lists and matrices across PFAS analysis methods here<\/a>&nbsp;or visit&nbsp;<a href=\"https:\/\/discover.restek.com\/pfas-analysis\/\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/pfas-analysis\/\">www.restek.com\/PFAS<\/a> to explore our technical resources for PFAS analysis.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Analyte List for ISO 21675:2019 for PFAS Analysis<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PFAS acronyms, compound names, and CAS numbers vary across methods and guidelines, and they also depend on compound form (e.g., neutral vs. salt). The following list uses standardized terminology to allow easy comparison across the methods and guidelines in our <a href=\"https:\/\/explore.restek.com\/PFAS-Guides\" target=\"_blank\" rel=\"noreferrer noopener\">comprehensive guide<\/a>. Please refer to ISO 21675:2019 for method-specific nomenclature.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Acronym<\/strong><\/td><td><strong>PFAS Name<\/strong><\/td><td><strong>CAS<\/strong><\/td><\/tr><tr><td>NEtFOSAA<\/td><td><em>N<\/em>-Ethyl perfluorooctanesulfonamidoacetic acid<\/td><td>2991-50-6<\/td><\/tr><tr><td>NMeFOSAA<\/td><td><em>N<\/em>-Methyl perfluorooctanesulfonamidoacetic acid<\/td><td>2355-31-9<\/td><\/tr><tr><td>PFBS<\/td><td>Perfluoro-1-butanesulfonic acid<\/td><td>375-73-5<\/td><\/tr><tr><td>PFDA<\/td><td>Perfluorodecanoic acid<\/td><td>335-76-2<\/td><\/tr><tr><td>PFDoA<\/td><td>Perfluorododecanoic acid<\/td><td>307-55-1<\/td><\/tr><tr><td>PFHpA<\/td><td>Perfluoroheptanoic acid<\/td><td>375-85-9<\/td><\/tr><tr><td>PFHxS<\/td><td>Perfluoro-1-hexanesulfonic acid<\/td><td>355-46-4<\/td><\/tr><tr><td>PFHxA<\/td><td>Perfluorohexanoic acid<\/td><td>307-24-4<\/td><\/tr><tr><td>PFNA<\/td><td>Perfluorononanoic acid<\/td><td>375-95-1<\/td><\/tr><tr><td>PFOS<\/td><td>Perfluorooctanesulfonic acid<\/td><td>1763-23-1<\/td><\/tr><tr><td>PFOA<\/td><td>Perfluorooctanoic acid<\/td><td>335-67-1<\/td><\/tr><tr><td>PFTeDA<\/td><td>Perfluorotetradecanoic acid<\/td><td>376-06-7<\/td><\/tr><tr><td>PFTrDA<\/td><td>Perfluorotridecanoic acid<\/td><td>72629-94-8<\/td><\/tr><tr><td>PFUnA<\/td><td>Perfluoroundecanoic acid<\/td><td>2058-94-8<\/td><\/tr><tr><td>HFPO-DA, GenX<\/td><td>Hexafluoropropylene oxide dimer acid<\/td><td>13252-13-6<\/td><\/tr><tr><td>PFBA<\/td><td>Perfluorobutanoic acid<\/td><td>375-22-4<\/td><\/tr><tr><td>PFPeA<\/td><td>Perfluoropentanoic acid<\/td><td>2706-90-3<\/td><\/tr><tr><td>PFDS<\/td><td>Perfluoro-1-decanesulfonic acid<\/td><td>335-77-3<\/td><\/tr><tr><td>PFHpS<\/td><td>Perfluoro-1-heptanesulfonic acid<\/td><td>375-92-8<\/td><\/tr><tr><td>FOSA<\/td><td>Perfluoro-1-octanesulfonamide<\/td><td>754-91-6<\/td><\/tr><tr><td>6:2 FTS<\/td><td>1<em>H<\/em>,1<em>H<\/em>,2<em>H<\/em>,2<em>H<\/em>-Perfluorooctane sulfonic acid<\/td><td>27619-97-2<\/td><\/tr><tr><td>8:2 FTS<\/td><td>1<em>H<\/em>,1<em>H<\/em>,2<em>H<\/em>,2<em>H<\/em>-Perfluorodecane sulfonic acid<\/td><td>39108-34-4<\/td><\/tr><tr><td>8:2 FTUCA, FOUEA<\/td><td>2<em>H<\/em>-Perfluoro-2-decenoic acid (8:2)<\/td><td>70887-84-2<\/td><\/tr><tr><td>8:2 diPAP<\/td><td>8:2 Polyfluoroalkyl phosphate diester<\/td><td>678-41-1<\/td><\/tr><tr><td>NMeFOSA<\/td><td><em>N<\/em>-Methylperfluorooctanesulfonamide<\/td><td>31506-32-8<\/td><\/tr><tr><td>NEtFOSA<\/td><td><em>N<\/em>-Ethylperfluorooctanesulfonamide<\/td><td>4151-50-2<\/td><\/tr><tr><td>PFHxDA<\/td><td>Perfluoro-<em>n<\/em>-hexadecanoic acid<\/td><td>67905-19-5<\/td><\/tr><tr><td>PFODA<\/td><td>Perfluoro-<em>n<\/em>-octadecanoic acid<\/td><td>16517-11-6<\/td><\/tr><tr><td>9Cl-PF3ONS<\/td><td>9-Chlorohexadecafluoro-3-oxanonane-1-sulfonic acid (F-53B Major)<\/td><td>756426-58-1<\/td><\/tr><tr><td>ADONA<\/td><td>4,8-Dioxa-3<em>H<\/em>-perfluorononanoic acid<\/td><td>919005-14-4<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-background wp-element-button\" href=\"https:\/\/explore.restek.com\/PFAS-Guides\" style=\"background-color:#015e9a;padding-right:50px;padding-left:50px\" target=\"_blank\" rel=\"noreferrer noopener\">Want to compare analyte lists? <em>Check out our guide!<\/em><\/a><\/div>\n<\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Recommended Products for ISO 21675:2019 for PFAS Analysis<\/h3>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Analytical LC Columns:<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A52\">                                R\u00e9f. 9304A52                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Colonne Raptor C18 2.7\u00b5m, 50 x 2.1 mm<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A52\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9634252\">                                R\u00e9f. 9634252                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Colonne LC Force C18, 1,8 \u03bcm 50 mm x 2.1 mm<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9634252\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Delay Columns:<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">                                R\u00e9f. 27854                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">\u201cColonne-retard\u201d PFAS HPLC, 5 \u00b5m, 50 x 2.1 mm<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">PFAS delay column: 5 \u00b5m, 50 x 3.0 mm (cat.# 580959 [custom product])<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Guard Columns:<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25809\">                                R\u00e9f. 25809                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Filtre\/pr\u00e9colonne UltraShield UHPLC, fritt\u00e9 0.2 \u03bcm, l\u2019unit\u00e9<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25809\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25808\">                                R\u00e9f. 25808                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Support de cartouche \u00e0 connexion directe EXP, livr\u00e9 avec un \u00e9crou et 2 ferrules<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25808\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A0252\">                                R\u00e9f. 9304A0252                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Cartouche de garde Raptor C18 EXP, 2.7 \u00b5m, L 5\u00a0x DI 2.1 mm, lot de 3<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A0252\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Sample Prep:<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23981\">                                R\u00e9f. 23981                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Filtres pour seringues\u00a030 mm, porosit\u00e9 0.45\u00a0\u00b5m, nylon, rose, lot de 100<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23981\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23980\">                                R\u00e9f. 23980                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Filtres pour seringues\u00a030 mm, porosit\u00e9 0.22\u00a0\u00b5m, nylon, rose, lot de 100<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23980\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28268\">                                R\u00e9f. 28268                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Cartouche SPE Polym\u00e9rique Resprep WAX, 6ml\/500mg, 30\u03bcm, pack de 30<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28268\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28292\">                                R\u00e9f. 28292                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Cartouche SPE Polym\u00e9rique Resprep WAX, 6ml\/200mg, 30\u03bcm, pack de 30<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28292\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26015\">                                R\u00e9f. 26015                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Tubes vides en polypropyl\u00e8ne pour SPE, r\u00e9servoir de 75 ml, lot de 12<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26015\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26007\">                                R\u00e9f. 26007                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Connecteurs pour cartouches SPE, 1, 3, 6, 10 ou 15\u00a0ml, polypropyl\u00e8ne, lot de 15<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26007\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<p class=\"wp-block-paragraph\">*Note that a glass fiber filter is mentioned in the method. However, nylon and polypropylene are widely accepted filter membrane materials for PFAS analysis.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Vacuum Manifolds:<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28299-VM\">                                R\u00e9f. 28299-VM                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Manifold sous-vide Resprep QR-24<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28299-VM\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28298-VM\">                                R\u00e9f. 28298-VM                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Manifold sous-vide Resprep QR-12<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28298-VM\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Vacuum Pumps:<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27426\">                                R\u00e9f. 27426                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Pompe \u00e0 vide Chemker 300 en PTFE, 20 L\/min, AC110 V, 60 Hz<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27426\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27427\">                                R\u00e9f. 27427                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Pompe \u00e0 vide Chemker 300 PTFE, 18 l\/min, 220 V, 50 Hz<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27427\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">General Lab Supplies:<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23243\">                                R\u00e9f. 23243                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Flacon \u00e0 volume limit\u00e9 \u00e0 visser, polypropyl\u00e8ne, 9\u00a0mm, 700\u00a0\u03bcl, 12 x 32\u00a0mm, lot de 100<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23243\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23246\">                                R\u00e9f. 23246                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Flacon \u00e0 volume limit\u00e9 \u00e0 visser, polypropyl\u00e8ne, 9\u00a0mm, 700\u00a0\u03bcl, 12 x 32\u00a0mm, lot de 1000<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23246\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23244\">                                R\u00e9f. 23244                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Bouchon \u00e0 visser, poly\u00e9thyl\u00e8ne (solide), membrane de 0.254 mm, transparent, 2.0\u00a0ml, 9 mm, lot de 100<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23244\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23247\">                                R\u00e9f. 23247                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Bouchon \u00e0 visser, poly\u00e9thyl\u00e8ne (solide), membrane de 0.254 mm, transparent, 2.0\u00a0ml, 9 mm, lot de 1000<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23247\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25846\">                                R\u00e9f. 25846                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Tubes vides en polypropyl\u00e8ne pour centrifugation de 50 ml, avec bouchons, lot de 50<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25846\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28290\">                                R\u00e9f. 28290                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Tubes vides en polypropyl\u00e8ne pour centrifugation de 50 ml, avec bouchons, lot de 500<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28290\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22775\">                                R\u00e9f. 22775                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Seringues NORM-JECT en plastique, 10 ml, embout &quot;luer lock&quot;, lot de 100<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22775\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22774\">                                R\u00e9f. 22774                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Seringues NORM-JECT en plastique, 5 ml, embout &quot;luer lock&quot;, lot de 100<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22774\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div class=\"wp-block-group hub-fullwidth-container has-theme-palette-9-background-color has-background\" style=\"margin-top:0px;margin-bottom:0px;padding-top:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><style>.kadence-column102266_b11f32-a2 > .kt-inside-inner-col{padding-top:45px;padding-right:0px;padding-bottom:45px;padding-left:0px;}.kadence-column102266_b11f32-a2 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column102266_b11f32-a2 > .kt-inside-inner-col{flex-direction:column;}.kadence-column102266_b11f32-a2 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column102266_b11f32-a2 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column102266_b11f32-a2{position:relative;}@media all and (max-width: 1024px){.kadence-column102266_b11f32-a2 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column102266_b11f32-a2 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column102266_b11f32-a2 hub-guttered-centered-container\"><div class=\"kt-inside-inner-col\"><style>.kb-row-layout-id102266_d863fc-6c > .kt-row-column-wrap{align-content:start;}:where(.kb-row-layout-id102266_d863fc-6c > .kt-row-column-wrap) > .wp-block-kadence-column{justify-content:start;}.kb-row-layout-id102266_d863fc-6c > .kt-row-column-wrap{column-gap:var(--global-kb-gap-md, 2rem);row-gap:var(--global-kb-gap-md, 2rem);padding-top:20px;padding-right:20px;padding-bottom:20px;padding-left:20px;grid-template-columns:minmax(0, 1fr);}.kb-row-layout-id102266_d863fc-6c{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;overflow:clip;isolation:isolate;}.kb-row-layout-id102266_d863fc-6c > .kt-row-layout-overlay{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;}.kb-row-layout-id102266_d863fc-6c > .kt-row-layout-overlay{opacity:0.30;}@media all and (max-width: 1024px){.kb-row-layout-id102266_d863fc-6c > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}@media all and (max-width: 767px){.kb-row-layout-id102266_d863fc-6c > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}<\/style><div class=\"kb-row-layout-wrap kb-row-layout-id102266_d863fc-6c alignnone wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-1-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<style>.kadence-column102266_19753c-12 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column102266_19753c-12 > .kt-inside-inner-col{flex-direction:column;}.kadence-column102266_19753c-12 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column102266_19753c-12 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column102266_19753c-12{position:relative;}@media all and (max-width: 1024px){.kadence-column102266_19753c-12 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column102266_19753c-12 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column102266_19753c-12\"><div class=\"kt-inside-inner-col\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-1024x1024.png\" alt=\"Icon depicting customer service person.\" class=\"wp-image-95744\" style=\"width:100px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-1024x1024.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-300x300.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-150x150.png 150w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-768x768.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic.png 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73, .wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73[data-kb-block=\"kb-adv-heading102266_a727d9-73\"]{margin-top:20px;text-align:center;font-size:48px;line-height:55px;font-weight:400;font-style:normal;font-family:'Open Sans';}.wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73, .wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73[data-kb-block=\"kb-adv-heading102266_a727d9-73\"] .kb-adv-text-inner{background-image:linear-gradient(270deg,rgb(4,137,214) 0%,rgb(1,94,155) 100%);background-clip:text;-webkit-box-decoration-break:clone;box-decoration-break:clone;-webkit-background-clip:text;-webkit-text-fill-color:transparent;}.wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73[data-kb-block=\"kb-adv-heading102266_a727d9-73\"] mark.kt-highlight{font-style:normal;-webkit-text-fill-color:initial !important;-webkit-background-clip:initial !important;background-clip:initial !important;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73[data-kb-block=\"kb-adv-heading102266_a727d9-73\"] img.kb-inline-image{width:150px;vertical-align:baseline;}@media all and (max-width: 1024px){.wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73, .wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73[data-kb-block=\"kb-adv-heading102266_a727d9-73\"]{font-size:40px;}}@media all and (max-width: 767px){.wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73, .wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73[data-kb-block=\"kb-adv-heading102266_a727d9-73\"]{font-size:36px;}}<\/style><h2 class=\"kt-adv-heading102266_a727d9-73 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading102266_a727d9-73\"><span class=\"kb-adv-text-inner\">Vous avez besoin d&#8217;aide pour vos analyses de PFAS ?<\/span><\/h2>\n\n\n<p class=\"has-text-align-center has-17-font-size has-theme-palette-3-color has-text-color has-link-color wp-elements-1 wp-block-paragraph\" style=\"padding-right:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);font-size:23px\">De la s\u00e9lection de la m\u00e9thode aux recommandations de produits, nos experts PFAS vous accompagnent pour d\u00e9velopper vos protocoles complexes et obtenir des r\u00e9sultats fiables et pr\u00e9cis.<\/p>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns102266_ef75ca-34{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns102266_ef75ca-34 .kt-button{font-weight:normal;font-style:normal;}.kt-btns102266_ef75ca-34 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns102266_ef75ca-34 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns102266_ef75ca-34 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns102266_ef75ca-34 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns102266_ef75ca-34 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns102266_ef75ca-34 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns102266_ef75ca-34 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns102266_ef75ca-34\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn102266_2ad5bb-ba.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn102266_2ad5bb-ba.kb-button{color:var(--global-palette9, #ffffff);background:#61b522;font-size:var(--global-kb-font-size-md, 1.25rem);border-top-left-radius:10px;border-top-right-radius:10px;border-bottom-right-radius:10px;border-bottom-left-radius:10px;border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}.kb-btn102266_2ad5bb-ba.kb-button .kb-svg-icon-wrap{color:var(--global-palette9, #ffffff);}.kb-btn102266_2ad5bb-ba.kb-button:hover .kb-svg-icon-wrap, .kb-btn102266_2ad5bb-ba.kb-button:focus .kb-svg-icon-wrap{color:#61b522;}.wp-block-kadence-advancedbtn .kb-btn102266_2ad5bb-ba.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn102266_2ad5bb-ba.kb-button:focus{color:#61b522;background:var(--global-palette9, #ffffff);border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn102266_2ad5bb-ba.kb-button{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn102266_2ad5bb-ba.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn102266_2ad5bb-ba.kb-button:focus{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}@media all and (max-width: 767px){.wp-block-kadence-advancedbtn .kb-btn102266_2ad5bb-ba.kb-button{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}.wp-block-kadence-advancedbtn .kb-btn102266_2ad5bb-ba.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn102266_2ad5bb-ba.kb-button:focus{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}<\/style><a class=\"kb-button kt-button button kb-btn102266_2ad5bb-ba kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-true wp-block-kadence-singlebtn kb-preset--outline\" href=\"https:\/\/explore.restek.com\/PFAS-FR\" target=\"_blank\" rel=\"noopener\"><span class=\"kt-btn-inner-text\"><strong>Contactez un expert PFAS<\/strong><\/span><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_arrowRight kt-btn-icon-side-right\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg><\/span><\/a><\/div>\n<\/div><\/div>\n\n<\/div><\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Discover More Solutions for PFAS Analysis!<\/h3>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns43461_f609fd-35{gap:var(--global-kb-gap-md, 2rem);justify-content:center;align-items:center;}.kt-btns43461_f609fd-35 .kt-button{font-weight:normal;font-style:normal;}.kt-btns43461_f609fd-35 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns43461_f609fd-35 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns43461_f609fd-35 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43461_f609fd-35 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns43461_f609fd-35 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns43461_f609fd-35 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43461_f609fd-35 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns43461_f609fd-35\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn43461_fd6840-92.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn43461_fd6840-92.kb-button{padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn43461_fd6840-92.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn43461_fd6840-92.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn43461_fd6840-92 kt-btn-size-large kt-btn-width-type-full kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/discover.restek.com\/articles\/evar3552\/guide-to-pfas-testing-methods\"><span class=\"kt-btn-inner-text\">Access Other PFAS Methods<\/span><\/a>\n\n<style>ul.menu .wp-block-kadence-advancedbtn .kb-btn43461_93414e-eb.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn43461_93414e-eb.kb-button{padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn43461_93414e-eb.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn43461_93414e-eb.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn43461_93414e-eb kt-btn-size-large kt-btn-width-type-full kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/discover.restek.com\/articles\/EVAR3498\/lab-supplies-for-pfas-analysis\/\"><span class=\"kt-btn-inner-text\">Compare Product Lists<\/span><\/a>\n\n<style>ul.menu .wp-block-kadence-advancedbtn .kb-btn43461_380462-3e.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn43461_380462-3e.kb-button{padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn43461_380462-3e.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn43461_380462-3e.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn43461_380462-3e kt-btn-size-large kt-btn-width-type-full kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/discover.restek.com\/pfas-analysis\/\"><span class=\"kt-btn-inner-text\">Explore More Technical Resources<\/span><\/a><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group hub-fullwidth-container\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><style>.kadence-column43461_0211bf-2f > .kt-inside-inner-col,.kadence-column43461_0211bf-2f > .kt-inside-inner-col:before{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;}.kadence-column43461_0211bf-2f > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column43461_0211bf-2f > .kt-inside-inner-col{flex-direction:column;}.kadence-column43461_0211bf-2f > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column43461_0211bf-2f > .kt-inside-inner-col{background-color:var(--global-palette2, #2B6CB0);background-image:url('https:\/\/discover.restek.com\/wp-content\/uploads\/GNLP4243-ad-ezlc-for-PFAS-desktop-1.jpg');background-size:cover;background-position:50% 0%;background-attachment:scroll;background-repeat:no-repeat;}.kadence-column43461_0211bf-2f > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column43461_0211bf-2f{position:relative;}.kadence-column43461_0211bf-2f, .kt-inside-inner-col > .kadence-column43461_0211bf-2f:not(.specificity){margin-top:45px;margin-bottom:10px;}@media all and (max-width: 1024px){.kadence-column43461_0211bf-2f > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column43461_0211bf-2f > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column43461_0211bf-2f kvs-sm-false hub-guttered-centered-container\"><div class=\"kt-inside-inner-col\"><style>.kb-row-layout-id43461_250607-e2 > .kt-row-column-wrap{align-content:start;}:where(.kb-row-layout-id43461_250607-e2 > .kt-row-column-wrap) > .wp-block-kadence-column{justify-content:start;}.kb-row-layout-id43461_250607-e2 > .kt-row-column-wrap{column-gap:var(--global-kb-gap-md, 2rem);row-gap:var(--global-kb-gap-md, 2rem);padding-top:48px;padding-right:48px;padding-bottom:48px;padding-left:48px;grid-template-columns:minmax(0, calc(65% - ((var(--global-kb-gap-md, 2rem) * 1 )\/2)))minmax(0, calc(35% - ((var(--global-kb-gap-md, 2rem) * 1 )\/2)));}.kb-row-layout-id43461_250607-e2 > .kt-row-layout-overlay{opacity:0.30;}@media all and (max-width: 1024px){.kb-row-layout-id43461_250607-e2 > .kt-row-column-wrap{grid-template-columns:minmax(0, 2fr) minmax(0, 1fr);}}@media all and (max-width: 767px){.kb-row-layout-id43461_250607-e2 > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}<\/style><div class=\"kb-row-layout-wrap kb-row-layout-id43461_250607-e2 alignnone wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-2-columns kt-row-layout-left-golden kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<style>.kadence-column43461_877228-bf > .kt-inside-inner-col{display:flex;}.kadence-column43461_877228-bf > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column43461_877228-bf > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column43461_877228-bf > .kt-inside-inner-col > .aligncenter{width:100%;}.kt-row-column-wrap > .kadence-column43461_877228-bf{align-self:center;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column43461_877228-bf{align-self:auto;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column43461_877228-bf > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column43461_877228-bf > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column43461_877228-bf{position:relative;}@media all and (max-width: 1024px){.kt-row-column-wrap > .kadence-column43461_877228-bf{align-self:center;}}@media all and (max-width: 1024px){.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column43461_877228-bf{align-self:auto;}}@media all and (max-width: 1024px){.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column43461_877228-bf > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 1024px){.kadence-column43461_877228-bf > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kt-row-column-wrap > .kadence-column43461_877228-bf{align-self:center;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column43461_877228-bf{align-self:auto;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column43461_877228-bf > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column43461_877228-bf > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column43461_877228-bf\"><div class=\"kt-inside-inner-col\"><\/div><\/div>\n\n\n<style>.kadence-column43461_810ac3-9d > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column43461_810ac3-9d > .kt-inside-inner-col{flex-direction:column;}.kadence-column43461_810ac3-9d > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column43461_810ac3-9d > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column43461_810ac3-9d{position:relative;}@media all and (max-width: 1024px){.kadence-column43461_810ac3-9d > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column43461_810ac3-9d > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column43461_810ac3-9d\"><div class=\"kt-inside-inner-col\"><style>.wp-block-kadence-advancedheading.kt-adv-heading43461_5b2e78-40, .wp-block-kadence-advancedheading.kt-adv-heading43461_5b2e78-40[data-kb-block=\"kb-adv-heading43461_5b2e78-40\"]{text-align:center;font-size:48px;line-height:54px;font-weight:400;font-style:normal;font-family:Inter;text-transform:none;}.wp-block-kadence-advancedheading.kt-adv-heading43461_5b2e78-40 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading43461_5b2e78-40[data-kb-block=\"kb-adv-heading43461_5b2e78-40\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading43461_5b2e78-40 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading43461_5b2e78-40[data-kb-block=\"kb-adv-heading43461_5b2e78-40\"] img.kb-inline-image{width:150px;vertical-align:baseline;}@media all and (max-width: 767px){.wp-block-kadence-advancedheading.kt-adv-heading43461_5b2e78-40, .wp-block-kadence-advancedheading.kt-adv-heading43461_5b2e78-40[data-kb-block=\"kb-adv-heading43461_5b2e78-40\"]{font-size:36px;}}<\/style>\n<h2 class=\"kt-adv-heading43461_5b2e78-40 wp-block-kadence-advancedheading has-theme-palette-9-color has-text-color\" data-kb-block=\"kb-adv-heading43461_5b2e78-40\">Start Saving <br>Time Today<\/h2>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading43461_78f02e-72, .wp-block-kadence-advancedheading.kt-adv-heading43461_78f02e-72[data-kb-block=\"kb-adv-heading43461_78f02e-72\"]{text-align:center;font-size:20px;font-weight:400;font-style:normal;font-family:'Open Sans';color:#dee2e6;}.wp-block-kadence-advancedheading.kt-adv-heading43461_78f02e-72 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading43461_78f02e-72[data-kb-block=\"kb-adv-heading43461_78f02e-72\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading43461_78f02e-72 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading43461_78f02e-72[data-kb-block=\"kb-adv-heading43461_78f02e-72\"] img.kb-inline-image{width:150px;vertical-align:baseline;}@media all and (max-width: 767px){.wp-block-kadence-advancedheading.kt-adv-heading43461_78f02e-72, .wp-block-kadence-advancedheading.kt-adv-heading43461_78f02e-72[data-kb-block=\"kb-adv-heading43461_78f02e-72\"]{font-size:16px;}}<\/style>\n<p class=\"kt-adv-heading43461_78f02e-72 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading43461_78f02e-72\">Develop PFAS Methods in Minutes with our Pro&nbsp;<em>EZ<\/em>LC Chromatogram Modeler<\/p>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns43461_897dc8-8a{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns43461_897dc8-8a .kt-button{font-weight:normal;font-style:normal;}.kt-btns43461_897dc8-8a .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns43461_897dc8-8a .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns43461_897dc8-8a .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43461_897dc8-8a .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns43461_897dc8-8a .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns43461_897dc8-8a .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43461_897dc8-8a .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns43461_897dc8-8a\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn43461_185328-a7.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn43461_185328-a7.kb-button{color:#0c115b;background:var(--global-palette9, #ffffff);font-size:16px;line-height:20px;font-family:'Open Sans';font-weight:600;border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-right-radius:8px;border-bottom-left-radius:8px;border-top:1px solid #015e9a;border-right:1px solid #015e9a;border-bottom:1px solid #015e9a;border-left:1px solid #015e9a;padding-top:12px;padding-right:16px;padding-bottom:12px;padding-left:16px;}.kb-btn43461_185328-a7.kb-button .kb-svg-icon-wrap{font-size:16px;--kb-button-icon-size:16px;}.wp-block-kadence-advancedbtn .kb-btn43461_185328-a7.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn43461_185328-a7.kb-button:focus{color:#0c115b;background:var(--global-palette9, #ffffff);}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn43461_185328-a7.kb-button{border-top:1px solid #015e9a;border-right:1px solid #015e9a;border-bottom:1px solid #015e9a;border-left:1px solid #015e9a;}}@media all and (max-width: 767px){.wp-block-kadence-advancedbtn .kb-btn43461_185328-a7.kb-button{border-top:1px solid #015e9a;border-right:1px solid #015e9a;border-bottom:1px solid #015e9a;border-left:1px solid #015e9a;}}<\/style><a class=\"kb-button kt-button button kb-btn43461_185328-a7 kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-true wp-block-kadence-singlebtn kb-preset--outline\" href=\"https:\/\/ez.restek.com\/proezlc\" target=\"_blank\" rel=\"noopener\"><span class=\"kt-btn-inner-text\">www.restek.com\/ezlc<\/span><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_arrowRight kt-btn-icon-side-right\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg><\/span><\/a><\/div>\n<\/div><\/div>\n\n<\/div><\/div><\/div><\/div>\n\n\n<style>.kadence-column43461_008cce-cd > .kt-inside-inner-col{display:flex;}.kadence-column43461_008cce-cd > .kt-inside-inner-col{padding-top:20px;padding-right:20px;padding-bottom:20px;padding-left:20px;}.kadence-column43461_008cce-cd > .kt-inside-inner-col,.kadence-column43461_008cce-cd > .kt-inside-inner-col:before{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;}.kadence-column43461_008cce-cd > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column43461_008cce-cd > .kt-inside-inner-col{flex-direction:column;justify-content:center;align-items:center;}.kadence-column43461_008cce-cd > .kt-inside-inner-col > .kb-image-is-ratio-size{align-self:stretch;}.kadence-column43461_008cce-cd > .kt-inside-inner-col > .wp-block-kadence-advancedgallery{align-self:stretch;}.kadence-column43461_008cce-cd > .kt-inside-inner-col > .aligncenter{width:100%;}.kt-row-column-wrap > .kadence-column43461_008cce-cd{align-self:center;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column43461_008cce-cd{align-self:auto;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column43461_008cce-cd > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column43461_008cce-cd > .kt-inside-inner-col{background-color:var(--global-palette2, #2B6CB0);}.kadence-column43461_008cce-cd > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column43461_008cce-cd{position:relative;}.kadence-column43461_008cce-cd, .kt-inside-inner-col > .kadence-column43461_008cce-cd:not(.specificity){margin-top:45px;margin-bottom:10px;}@media all and (max-width: 1024px){.kt-row-column-wrap > .kadence-column43461_008cce-cd{align-self:center;}}@media all and (max-width: 1024px){.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column43461_008cce-cd{align-self:auto;}}@media all and (max-width: 1024px){.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column43461_008cce-cd > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 1024px){.kadence-column43461_008cce-cd > .kt-inside-inner-col{flex-direction:column;justify-content:center;align-items:center;}}@media all and (max-width: 767px){.kt-row-column-wrap > .kadence-column43461_008cce-cd{align-self:center;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column43461_008cce-cd{align-self:auto;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column43461_008cce-cd > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column43461_008cce-cd > .kt-inside-inner-col{flex-direction:column;justify-content:center;align-items:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column43461_008cce-cd kvs-lg-false kvs-md-false hub-guttered-centered-container\"><div class=\"kt-inside-inner-col\"><style>.wp-block-kadence-advancedheading.kt-adv-heading43461_88e5cf-78, .wp-block-kadence-advancedheading.kt-adv-heading43461_88e5cf-78[data-kb-block=\"kb-adv-heading43461_88e5cf-78\"]{text-align:center;font-size:48px;line-height:54px;font-weight:400;font-style:normal;font-family:Inter;text-transform:none;}.wp-block-kadence-advancedheading.kt-adv-heading43461_88e5cf-78 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading43461_88e5cf-78[data-kb-block=\"kb-adv-heading43461_88e5cf-78\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading43461_88e5cf-78 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading43461_88e5cf-78[data-kb-block=\"kb-adv-heading43461_88e5cf-78\"] img.kb-inline-image{width:150px;vertical-align:baseline;}@media all and (max-width: 767px){.wp-block-kadence-advancedheading.kt-adv-heading43461_88e5cf-78, .wp-block-kadence-advancedheading.kt-adv-heading43461_88e5cf-78[data-kb-block=\"kb-adv-heading43461_88e5cf-78\"]{font-size:36px;}}<\/style>\n<h2 class=\"kt-adv-heading43461_88e5cf-78 wp-block-kadence-advancedheading has-theme-palette-9-color has-text-color\" data-kb-block=\"kb-adv-heading43461_88e5cf-78\">Start Saving Time Today<\/h2>\n\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading43461_5363d4-b4, .wp-block-kadence-advancedheading.kt-adv-heading43461_5363d4-b4[data-kb-block=\"kb-adv-heading43461_5363d4-b4\"]{text-align:center;font-size:20px;font-weight:400;font-style:normal;font-family:'Open Sans';color:#dee2e6;}.wp-block-kadence-advancedheading.kt-adv-heading43461_5363d4-b4 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading43461_5363d4-b4[data-kb-block=\"kb-adv-heading43461_5363d4-b4\"] mark.kt-highlight{font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading43461_5363d4-b4 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading43461_5363d4-b4[data-kb-block=\"kb-adv-heading43461_5363d4-b4\"] img.kb-inline-image{width:150px;vertical-align:baseline;}@media all and (max-width: 767px){.wp-block-kadence-advancedheading.kt-adv-heading43461_5363d4-b4, .wp-block-kadence-advancedheading.kt-adv-heading43461_5363d4-b4[data-kb-block=\"kb-adv-heading43461_5363d4-b4\"]{font-size:16px;}}<\/style>\n<p class=\"kt-adv-heading43461_5363d4-b4 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading43461_5363d4-b4\">Develop PFAS Methods in Minutes with our Pro&nbsp;<em>EZ<\/em>LC Chromatogram Modeler<\/p>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns43461_80f851-f2{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns43461_80f851-f2 .kt-button{font-weight:normal;font-style:normal;}.kt-btns43461_80f851-f2 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns43461_80f851-f2 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns43461_80f851-f2 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43461_80f851-f2 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns43461_80f851-f2 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns43461_80f851-f2 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns43461_80f851-f2 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns43461_80f851-f2\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn43461_104ba9-22.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn43461_104ba9-22.kb-button{color:#0c115b;background:var(--global-palette9, #ffffff);font-size:16px;line-height:20px;font-family:'Open Sans';font-weight:600;border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-right-radius:8px;border-bottom-left-radius:8px;border-top:1px solid #015e9a;border-right:1px solid #015e9a;border-bottom:1px solid #015e9a;border-left:1px solid #015e9a;padding-top:12px;padding-right:16px;padding-bottom:12px;padding-left:16px;}.kb-btn43461_104ba9-22.kb-button .kb-svg-icon-wrap{font-size:16px;--kb-button-icon-size:16px;}.wp-block-kadence-advancedbtn .kb-btn43461_104ba9-22.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn43461_104ba9-22.kb-button:focus{color:#0c115b;background:var(--global-palette9, #ffffff);}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn43461_104ba9-22.kb-button{border-top:1px solid #015e9a;border-right:1px solid #015e9a;border-bottom:1px solid #015e9a;border-left:1px solid #015e9a;}}@media all and (max-width: 767px){.wp-block-kadence-advancedbtn .kb-btn43461_104ba9-22.kb-button{border-top:1px solid #015e9a;border-right:1px solid #015e9a;border-bottom:1px solid #015e9a;border-left:1px solid #015e9a;}}<\/style><a class=\"kb-button kt-button button kb-btn43461_104ba9-22 kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-true wp-block-kadence-singlebtn kb-preset--outline\" href=\"https:\/\/ez.restek.com\/proezlc\" target=\"_blank\" rel=\"noopener\"><span class=\"kt-btn-inner-text\">www.restek.com\/ezlc<\/span><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_arrowRight kt-btn-icon-side-right\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg><\/span><\/a><\/div>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Simplify your ISO 21675:2019 testing workflow with this high-level overview and convenient list of recommended products for analyzing PFAS in water containing <2 g\/L solids.\n<\/p>\n","protected":false},"author":11,"featured_media":6673,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[7],"tags":[2782],"industries-application":[2255,2253,2257,2766],"post-badge":[],"resource-type":[567],"product-library":[2535,2517,2544,2519,2546,2549],"resource-technique":[2334,2364,2337],"ppma_author":[414],"class_list":["post-43461","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles","tag-pfas","industries-application-acque-potabili-acque-reflue","industries-application-ambientale","industries-application-analisi-dei-pfas","industries-application-semivolatiles","resource-type-selection-guides","product-library-colonne-lc","product-library-prodotti-per-cromatografia-liquida","product-library-prodotti-quechers","product-library-prodotti-per-la-preparazione-del-campione","product-library-spe-sle-prodotti","product-library-vial-accessori","resource-technique-cromatografia-liquida-lc","resource-technique-ms-ms-it","resource-technique-estrazione-in-fase-solida-spe"],"acf":[],"taxonomy_info":{"category":[{"value":7,"label":"Articles"}],"post_tag":[{"value":2782,"label":"PFAS"}],"industries-application":[{"value":2255,"label":"Acque Potabili e Acque Reflue"},{"value":2253,"label":"Ambientale"},{"value":2257,"label":"Analisi dei PFAS"},{"value":2766,"label":"Semivolatiles"}],"resource-type":[{"value":567,"label":"Selection Guides"}],"product-library":[{"value":2535,"label":"Colonne LC"},{"value":2517,"label":"Prodotti per Cromatografia Liquida"},{"value":2544,"label":"Prodotti QuEChERS"},{"value":2519,"label":"Prodotti per la Preparazione del Campione"},{"value":2546,"label":"SPE &amp; SLE"},{"value":2549,"label":"Vial e Accessori"}],"resource-technique":[{"value":2334,"label":"Cromatografia Liquida (LC)"},{"value":2364,"label":"MS\/MS"},{"value":2337,"label":"Estrazione in Fase Solida (SPE)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVAR4300-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":506,"filter":"raw","cat_ID":7,"category_count":506,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":[{"term_id":2782,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2782,"taxonomy":"post_tag","description":"","parent":0,"count":126,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43461","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=43461"}],"version-history":[{"count":12,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43461\/revisions"}],"predecessor-version":[{"id":100637,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43461\/revisions\/100637"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/6673"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=43461"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=43461"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=43461"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=43461"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=43461"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=43461"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=43461"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=43461"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=43461"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}