{"id":43487,"date":"2026-08-28T13:38:50","date_gmt":"2026-08-28T13:38:50","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/nouvelle-phase-stationnaire-pour-lanalyse-des-pfas\/"},"modified":"2026-04-29T13:46:50","modified_gmt":"2026-04-29T13:46:50","slug":"nouvelle-phase-stationnaire-pour-lanalyse-des-pfas","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/articles-fr\/evfa3197-fr\/nouvelle-phase-stationnaire-pour-lanalyse-des-pfas","title":{"rendered":"Nouvelle phase stationnaire pour l\u2019analyse des PFAS"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>Phase stationnaire unique permettant \u00e0 la fois la r\u00e9tention des PFAS polaires \u00e0 chaines ultra-courtes et des PFAS \u00e0 chaines courtes et longues.<\/li>\n\n\n\n<li>M\u00e9thode isocratique LC-MS\/MS simple permettant un dosage rapide des PFAS.<\/li>\n\n\n\n<li>R\u00e9sultats fiables gr\u00e2ce \u00e0 des performances reproductibles.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Les m\u00e9thodes LCMSMS actuelles d\u2019analyse des substances polyfluoroalkyles (PFAS) sont focalis\u00e9es sur les compos\u00e9s \u00e0 chaines courtes (C4-C6) et \u00e0 chaines longues (C8 et au-del\u00e0), ainsi que sur les substances de remplacement de ces compos\u00e9s. Elles n\u2019incluent pas les nouveaux compos\u00e9s d\u2019int\u00e9r\u00eat que sont les PFAS \u00e0 chaines ultra-courtes (C2 et C3). Ces compos\u00e9s gagnent en importance car ils sont omnipr\u00e9sents dans les eaux environnementales (ex. les eaux de pluie, de rivi\u00e8re ou les nappes phr\u00e9atiques) et repr\u00e9sentent au moins 40% de la quantit\u00e9 totale des PFAS pr\u00e9sents dans les \u00e9chantillons d\u2019eaux. Les PFAS \u00e0 chaines ultra-courtes incluent l\u2019acide trifluoroac\u00e9tique (TFA), l\u2019acide perfluoropropanoique (PFPrA), le sulfonate de perfluoro\u00e9thane (PFEtS) et le sulfonate de perfluoropropane (PFPrS), le TFA \u00e9tant \u00e0 la fois le compos\u00e9 le plus abondant et l\u2019un des plus complexes \u00e0 analyser. La mise au point de m\u00e9thodes r\u00e9ellement compl\u00e8tes, permettant d\u2019obtenir des r\u00e9sultats fiables pour les PFAS \u00e0 chaines ultra-courtes (dont le TFA), ainsi que pour les PFAS conventionnels et leurs mol\u00e9cules alternatives, s\u2019av\u00e8re donc essentielle pour les programmes de surveillance des eaux.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les principales difficult\u00e9s li\u00e9es \u00e0 l\u2019analyse du TFA sont ses faibles qualit\u00e9s de r\u00e9tention et d\u2019\u00e9lution sur les colonnes en phase inverse ou en mode HILIC. Les colonnes alternatives reposant sur des m\u00e9canismes d\u2019\u00e9change ionique fort peuvent poser le probl\u00e8me inverse, \u00e0 savoir une r\u00e9tention trop forte et une forme de pic d\u00e9grad\u00e9e. Par opposition, le TFA peut \u00eatre analys\u00e9 de mani\u00e8re fiable sur les colonnes Raptor Polar X, car elles pr\u00e9sentent un greffon hybride innovant combinant les m\u00e9canismes de r\u00e9tention HILIC et d\u2019\u00e9change d\u2019ions. Ce document pr\u00e9sente une m\u00e9thode LCMSMS simple et rapide d\u2019analyse globale des PFAS, incluant les cha\u00eenes C2, C3, C4, C6, C8, et les PFAS alternatifs. L\u2019analyse de chaines encore plus longues est \u00e9galement possible. Cette m\u00e9thode peut \u00eatre appliqu\u00e9e \u00e0 l\u2019analyse des eaux potables comme \u00e0 celle des eaux non-potables, et permettra aux laboratoires d\u2019ajouter les compos\u00e9s \u00e0 chaines ultra-courtes \u00e0 leurs m\u00e9thodes existantes d\u2019analyse de PFAS.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Analyse globale des PFAS \u00e0 chaines ultra-courtes (C2,C3), PFAS conventionnels et compos\u00e9s alternatifs<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0569.png\" alt=\"Ultrashort- Through Long-Chain and Alternative PFAS on Raptor Polar X\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0569<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/L)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\">11-Chloroeicosafluoro-3-oxanonane-1-sulfonate (11CL-PF3OUdS)<\/td><td class=\"oth\">1.25<\/td><td class=\"oth\">400<\/td><td class=\"oth\">630.78<\/td><td class=\"oth\">450.80<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\">9-Chlorohexadecafluoro-3-oxanonane-1-sulfonate (9Cl-PF3ONS)<\/td><td class=\"oth\">1.34<\/td><td class=\"oth\">400<\/td><td class=\"oth\">530.78<\/td><td class=\"oth\">350.85<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorooctanesulfonic acid (PFOS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1763-23-1\/Perfluorooctanesulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorooctanesulfonic acid (PFOS)<\/a><\/td><td class=\"oth\">1.38<\/td><td class=\"oth\">400<\/td><td class=\"oth\">498.84<\/td><td class=\"oth\">79.97<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorohexanesulfonic acid (PFHxS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/355-46-4\/Perfluorohexanesulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorohexanesulfonic acid (PFHxS)<\/a><\/td><td class=\"oth\">1.49<\/td><td class=\"oth\">400<\/td><td class=\"oth\">398.90<\/td><td class=\"oth\">79.97<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorobutanesulfonic acid (PFBS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-73-5\/Perfluorobutanesulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorobutanesulfonic acid (PFBS)<\/a><\/td><td class=\"oth\">1.64<\/td><td class=\"oth\">400<\/td><td class=\"oth\">298.97<\/td><td class=\"oth\">79.97<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\">Perfluoropropanesulfonic acid (PFPrS)<\/td><td class=\"oth\">1.73<\/td><td class=\"oth\">400<\/td><td class=\"oth\">248.97<\/td><td class=\"oth\">79.98<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\">Perfluoroethanesulfonic acid (PFEtS)<\/td><td class=\"oth\">1.86<\/td><td class=\"oth\">400<\/td><td class=\"oth\">198.98<\/td><td class=\"oth\">79.92<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/L)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexafluoropropylene oxide dimer acid (HFPO-DA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13252-13-6\/Hexafluoropropylene oxide dimer acid\" target=\"_blank\" rel=\"noopener\">Hexafluoropropylene oxide dimer acid (HFPO-DA)<\/a><\/td><td class=\"oth\">2.06<\/td><td class=\"oth\">400<\/td><td class=\"oth\">284.97<\/td><td class=\"oth\">168.92<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorooctanoic acid (PFOA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/335-67-1\/Perfluorooctanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorooctanoic acid (PFOA)<\/a><\/td><td class=\"oth\">2.11<\/td><td class=\"oth\">400<\/td><td class=\"oth\">412.90<\/td><td class=\"oth\">368.91<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ammonium 4,8-dioxa-3H-perfluorononanoate (ADONA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/919005-14-4\/Ammonium 4,8-dioxa-3H-perfluorononanoate\" target=\"_blank\" rel=\"noopener\">Ammonium 4,8-dioxa-3H-perfluorononanoate (ADONA)<\/a><\/td><td class=\"oth\">2.15<\/td><td class=\"oth\">400<\/td><td class=\"oth\">376.90<\/td><td class=\"oth\">250.93<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorohexanoic acid (PFHxA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/307-24-4\/Perfluorohexanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorohexanoic acid (PFHxA)<\/a><\/td><td class=\"oth\">2.36<\/td><td class=\"oth\">400<\/td><td class=\"oth\">312.97<\/td><td class=\"oth\">268.90<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorobutanoic acid (PFBA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-22-4\/Perfluorobutanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorobutanoic acid (PFBA)<\/a><\/td><td class=\"oth\">2.76<\/td><td class=\"oth\">400<\/td><td class=\"oth\">212.97<\/td><td class=\"oth\">168.97<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\">Perfluoropropionic acid (PFPrA)<\/td><td class=\"oth\">3.06<\/td><td class=\"oth\">400<\/td><td class=\"oth\">163.03<\/td><td class=\"oth\">119.01<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Trifluoroacetic acid (TFA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-05-1\/Trifluoroacetic acid\" target=\"_blank\" rel=\"noopener\">Trifluoroacetic acid (TFA)<\/a><\/td><td class=\"oth\">3.77<\/td><td class=\"oth\">400<\/td><td class=\"oth\">113.03<\/td><td class=\"oth\">69.01<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor Polar X  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9311A52\" rel=\"noopener\">cat.# 9311A52<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>50 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>50:50 Water:methanol<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>400  ng\/L<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>10 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 10 mM ammonium formate, 0.05% formic acid   <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>60:40 Acetonitrile:methanol, 0.05% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.5<\/td><td>15<\/td><td>85<\/td><\/tr><tr><td>8.00<\/td><td>0.5<\/td><td>15<\/td><td>85<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>UHPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>To achieve more stable and robust performance with Polar X columns, the recommended LC conditions have changed from those that were used here. The new recommended conditions are an aqueous mobile phase (mobile phase A) consisting of 5 mM or 10 mM ammonium formate with 0.1% formic acid in water and an organic mobile phase (mobile phase B) of 100% acetonitrile. Higher ammonium formate concentrations will result in reduced analyte retention. Therefore, laboratories can optimize retention by adjusting both the ammonium formate concentration and the flow rate to best meet their analytical requirements. In addition, it is recommended that labs evaluate different isocratic conditions by varying the amount of mobile phase B between 70% and 85% acetonitrile. This approach can help labs identify the most suitable separation conditions for their specific target analytes and sample matrices of interest.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9311A52<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>PFAS<\/li><li>PFAS-library<\/li><li>ultrashort-chain<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0569.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Dans cette m\u00e9thode LC-MS\/MS isocratique, les colonnes Raptor Polar X permettent \u00e0 la fois la r\u00e9tention des PFAS polaires \u00e0 chaines ultra-courtes et des PFAS \u00e0 chaines courtes et longues.<\/p>\n","protected":false},"author":11,"featured_media":6717,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[462],"tags":[2782],"industries-application":[2212,2210,2208,2758],"post-badge":[],"resource-type":[],"product-library":[2463,2445],"resource-technique":[2318,2362],"ppma_author":[414],"class_list":["post-43487","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-fr","tag-pfas","industries-application-analyse-de-pfas","industries-application-eau-potable-eaux-usees","industries-application-environnement","industries-application-semivolatiles","product-library-colonnes-lc","product-library-produits-pour-la-chromatographie-en-phase-liquide","resource-technique-chromatographie-en-phase-liquide","resource-technique-ms-ms-fr"],"acf":[],"taxonomy_info":{"category":[{"value":462,"label":"Articles"}],"post_tag":[{"value":2782,"label":"PFAS"}],"industries-application":[{"value":2212,"label":"Analyse de PFAS"},{"value":2210,"label":"Eau potable et eaux us\u00e9es"},{"value":2208,"label":"Environnement"},{"value":2758,"label":"Semivolatiles"}],"product-library":[{"value":2463,"label":"Colonnes LC"},{"value":2445,"label":"Produits pour la chromatographie en phase liquide"}],"resource-technique":[{"value":2318,"label":"Chromatographie en phase liquide"},{"value":2362,"label":"MS\/MS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVFA3197-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":462,"name":"Articles","slug":"articles-fr","term_group":0,"term_taxonomy_id":462,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":462,"category_count":511,"category_description":"","cat_name":"Articles","category_nicename":"articles-fr","category_parent":0}],"tag_info":[{"term_id":2782,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2782,"taxonomy":"post_tag","description":"","parent":0,"count":124,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43487","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=43487"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43487\/revisions"}],"predecessor-version":[{"id":94016,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43487\/revisions\/94016"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/6717"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=43487"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=43487"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=43487"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=43487"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=43487"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=43487"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=43487"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=43487"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=43487"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}