{"id":43497,"date":"2022-05-11T00:00:00","date_gmt":"2022-05-11T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/analyse-des-hydrocarbures-aromatiques-polycycliques-hap-par-gc-ms\/"},"modified":"2025-12-31T14:50:27","modified_gmt":"2025-12-31T14:50:27","slug":"analyse-des-hydrocarbures-aromatiques-polycycliques-hap-par-gc-ms","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/articles-fr\/evfa3822-fr\/analyse-des-hydrocarbures-aromatiques-polycycliques-hap-par-gc-ms","title":{"rendered":"Analyse des hydrocarbures aromatiques polycycliques (HAP) par GC-MS"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-border-color is-layout-flow wp-block-column-is-layout-flow\" style=\"border-color:#e67e23;border-width:1px;padding-top:10px;padding-right:20px;padding-bottom:10px;padding-left:20px;flex-basis:75%\">\n<p class=\"has-text-color has-link-color wp-elements-be6be55f2a271cf6ab1f2651de37c0fc wp-block-paragraph\" style=\"color:#e67e23\"><strong><em>Notre colonne GC Rxi-SVOCms a \u00e9t\u00e9 d\u00e9sign\u00e9e meilleur nouveau produit de l&#8217;ann\u00e9e (&#8220;Best New Analytical Science Product&#8221;) dans le cadre des SelectScience Scientists&#8217; Choice Awards.<\/em><\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li>La colonne Rxi-SVOCms offre une meilleure s\u00e9paration et une bonne r\u00e9ponse pour les HAP critiques pr\u00e9sents dans l\u2019environnement.<\/li>\n\n\n\n<li>Le faible &#8220;bleeding&#8221; garantit la justesse pour les analytes cibles \u00e9lu\u00e9s tardivement.<\/li>\n\n\n\n<li>L\u2019analyse en mode SIM &#8220;Selected Ion Monitoring&#8221; avec injection &#8220;split&#8221; permet de r\u00e9duire la discrimination dans l\u2019injecteur.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Les hydrocarbures aromatiques polycycliques (HAP) sont des contaminants environnementaux d\u2019origine naturelle ou anthropique omnipr\u00e9sents et issus principalement de la combustion incompl\u00e8te de mati\u00e8res contenant du carbone. Comme certains hydrocarbures aromatiques polycycliques sont class\u00e9s canc\u00e9rog\u00e8nes, la surveillance de leur faible concentration dans les matrices environnementales (air, eau et sol) est essentielle pour \u00e9valuer le taux d\u2019exposition. L\u2019analyse des HAP par GC-MS sur une colonne Rxi-SVOCms dans des conditions optimis\u00e9es, repr\u00e9sent\u00e9e ci-dessous, fournit une d\u00e9tection efficace des compos\u00e9s les plus pertinents.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En mode SIM avec injection &#8220;split&#8221; pour r\u00e9duire la discrimination dans l\u2019injecteur pour un \u00e9chantillon complexe de goudron de houille, les r\u00e9sultats chromatographiques observ\u00e9s \u00e9taient excellents pour une multitude de HAP. Les compos\u00e9s volatils \u00e0 \u00e9lution pr\u00e9coce produisent des pics fins et de bonnes r\u00e9ponses tandis que le faible &#8220;bleeding&#8221; r\u00e9duit les interf\u00e9rences des niveaux de bruit de fond au minimum et am\u00e9liore la sensibilit\u00e9 pour les compos\u00e9s \u00e9lu\u00e9s plus tardivement. De plus, l\u2019efficacit\u00e9 et la s\u00e9lectivit\u00e9 de la colonne Rxi-SVOCms ont abouti \u00e0 une meilleure s\u00e9paration de HAP isobares comme le benzo(b)fluoranth\u00e8ne et le benzo(k)fluoranth\u00e8ne. L\u2019ind\u00e9no[123-cd]pyr\u00e8ne et le dibenz[ah]anthrac\u00e8ne ont \u00e9galement \u00e9t\u00e9 mieux s\u00e9par\u00e9s avec une bonne r\u00e9solution (m\u00eame lorsque la r\u00e9ponse est disproportionn\u00e9e), ce qui r\u00e9duit \u00e9norm\u00e9ment le risque de r\u00e9sultats biais\u00e9s et de faux positifs.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong>\u00a0L\u2019efficacit\u00e9 et la s\u00e9lectivit\u00e9 des colonnes Rxi-SVOCms garantissent une excellente s\u00e9paration des paires critiques pour l\u2019analyse des HAP par GC-MS.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1606.png\" alt=\"Complex Mixture of Polycyclic Aromatic Hydrocarbons from Coal Tar on Rxi-SVOCms (SIM)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1606<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Naphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-20-3\/Naphthalene\" target=\"_blank\" rel=\"noopener\">Naphthalene<\/a><\/td><td class=\"oth\">6.27<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Methylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-57-6\/2-Methylnaphthalene\" target=\"_blank\" rel=\"noopener\">2-Methylnaphthalene<\/a><\/td><td class=\"oth\">7.09<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Methylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90-12-0\/1-Methylnaphthalene\" target=\"_blank\" rel=\"noopener\">1-Methylnaphthalene<\/a><\/td><td class=\"oth\">7.21<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Biphenyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92-52-4\/Biphenyl\" target=\"_blank\" rel=\"noopener\">Biphenyl<\/a><\/td><td class=\"oth\">7.66<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,6-Dimethylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/581-42-0\/2,6-Dimethylnaphthalene\" target=\"_blank\" rel=\"noopener\">2,6-Dimethylnaphthalene<\/a><\/td><td class=\"oth\">7.84<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/208-96-8\/Acenaphthylene\" target=\"_blank\" rel=\"noopener\">Acenaphthylene<\/a><\/td><td class=\"oth\">8.17<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (IS) Acenaphthene-d10\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/15067-26-2\/(IS) Acenaphthene-d10\" target=\"_blank\" rel=\"noopener\">(IS) Acenaphthene-d10<\/a><\/td><td class=\"oth\">8.35<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/83-32-9\/Acenaphthene\" target=\"_blank\" rel=\"noopener\">Acenaphthene<\/a><\/td><td class=\"oth\">8.39<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,3,5-Trimethylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2245-38-7\/2,3,5-Trimethylnaphthalene\" target=\"_blank\" rel=\"noopener\">2,3,5-Trimethylnaphthalene<\/a><\/td><td class=\"oth\">8.86<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluorene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/86-73-7\/Fluorene\" target=\"_blank\" rel=\"noopener\">Fluorene<\/a><\/td><td class=\"oth\">9.02<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenzothiophene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/132-65-0\/Dibenzothiophene\" target=\"_blank\" rel=\"noopener\">Dibenzothiophene<\/a><\/td><td class=\"oth\">10.03<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (IS) Phenanthrene-D10\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1517-22-2\/(IS) Phenanthrene-D10\" target=\"_blank\" rel=\"noopener\">(IS) Phenanthrene-D10<\/a><\/td><td class=\"oth\">10.16<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenanthrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85-01-8\/Phenanthrene\" target=\"_blank\" rel=\"noopener\">Phenanthrene<\/a><\/td><td class=\"oth\">10.19<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-12-7\/Anthracene\" target=\"_blank\" rel=\"noopener\">Anthracene<\/a><\/td><td class=\"oth\">10.25<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Methylphenanthrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/832-69-9\/1-Methylphenanthrene\" target=\"_blank\" rel=\"noopener\">1-Methylphenanthrene<\/a><\/td><td class=\"oth\">10.95<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/206-44-0\/Fluoranthene\" target=\"_blank\" rel=\"noopener\">Fluoranthene<\/a><\/td><td class=\"oth\">11.65<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/129-00-0\/Pyrene\" target=\"_blank\" rel=\"noopener\">Pyrene<\/a><\/td><td class=\"oth\">11.92<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benz[a]anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-55-3\/Benz[a]anthracene\" target=\"_blank\" rel=\"noopener\">Benz[a]anthracene<\/a><\/td><td class=\"oth\">13.46<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (IS) Chrysene-D12\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1719-03-5\/(IS) Chrysene-D12\" target=\"_blank\" rel=\"noopener\">(IS) Chrysene-D12<\/a><\/td><td class=\"oth\">13.47<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chrysene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/218-01-9\/Chrysene\" target=\"_blank\" rel=\"noopener\">Chrysene<\/a><\/td><td class=\"oth\">13.51<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[b]fluoranthene*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/205-99-2\/Benzo[b]fluoranthene\" target=\"_blank\" rel=\"noopener\">Benzo[b]fluoranthene*<\/a><\/td><td class=\"oth\">15.14<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[k]fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/207-08-9\/Benzo[k]fluoranthene\" target=\"_blank\" rel=\"noopener\">Benzo[k]fluoranthene<\/a><\/td><td class=\"oth\">15.19<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (SS) Benzo[a]pyrene-d12\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/63466-71-7\/(SS) Benzo[a]pyrene-d12\" target=\"_blank\" rel=\"noopener\">(SS) Benzo[a]pyrene-d12<\/a><\/td><td class=\"oth\">15.66<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[a]pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-32-8\/Benzo[a]pyrene\" target=\"_blank\" rel=\"noopener\">Benzo[a]pyrene<\/a><\/td><td class=\"oth\">15.70<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Indeno[1,2,3-cd]pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/193-39-5\/Indeno[1,2,3-cd]pyrene\" target=\"_blank\" rel=\"noopener\">Indeno[1,2,3-cd]pyrene<\/a><\/td><td class=\"oth\">17.78<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenz[a,h]anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53-70-3\/Dibenz[a,h]anthracene\" target=\"_blank\" rel=\"noopener\">Dibenz[a,h]anthracene<\/a><\/td><td class=\"oth\">17.83<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[ghi]perylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/191-24-2\/Benzo[ghi]perylene\" target=\"_blank\" rel=\"noopener\">Benzo[ghi]perylene<\/a><\/td><td class=\"oth\">18.27<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">* Benzo[b]fluoranthene and benzo[j]fluoranthene coelution.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rxi-SVOCms, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/16623\" rel=\"noopener\">cat.# 16623<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>NIST SRM 1597a &#8211; complex mixture of polycyclic aromatic hydrocarbons from coal tar<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Dichloromethane<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 20:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 4.0 mm ID single taper inlet liner with wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23303\" rel=\"noopener\">cat.# 23303<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Split Vent Flow Rate:<\/th><td>24 mL\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>40 &#176;C (hold 0.5 min) to 280 &#176;C at 20 &#176;C\/min to 330 &#176;C at 6 &#176;C\/min (hold 4 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.2 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>SIM<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">SIM Program:<\/th><td><\/td><\/tr><tr><td style=\"text-align:left\" colspan=\"2\"><table class=\"conditions_sim\"><thead><tr><th style=\"padding: 0 5px\">Group<\/th><th style=\"padding: 0 5px\">Start Time<br \/>(min)<\/th><th style=\"padding: 0 5px\">Ion(s) (m\/z)<\/th><th style=\"padding: 0 5px\">Dwell (ms)<\/th><\/tr><\/thead><tbody><tr><td style=\"vertical-align:top\">1<\/td><td style=\"vertical-align:top\">5.00<\/td><td>127.05, 128.05, 129.00 <\/td><td>10<\/td><\/tr><tr><td style=\"vertical-align:top\">2<\/td><td style=\"vertical-align:top\">6.75<\/td><td>115.10, 139.00, 141.00, 142.05 <\/td><td>10<\/td><\/tr><tr><td style=\"vertical-align:top\">3<\/td><td style=\"vertical-align:top\">7.47<\/td><td>141.00, 152.00, 153.05, 154.05, 155.05, 156.10, 162.10, 164.10 <\/td><td>10<\/td><\/tr><tr><td style=\"vertical-align:top\">4<\/td><td style=\"vertical-align:top\">8.03<\/td><td>150.00, 151.05, 152.05, 153.05, 154.10, 162.10, 164.10 <\/td><td>10<\/td><\/tr><tr><td style=\"vertical-align:top\">5<\/td><td style=\"vertical-align:top\">8.66<\/td><td>153.05, 155.10, 163.05, 164.10, 165.05, 166.05, 169.10, 170.10 <\/td><td>10<\/td><\/tr><tr><td style=\"vertical-align:top\">6<\/td><td style=\"vertical-align:top\">9.62<\/td><td>139.00, 151.95, 176.10, 177.10, 178.10, 179.10, 183.95, 185.00, 188.10, 189.10 <\/td><td>10<\/td><\/tr><tr><td style=\"vertical-align:top\">7<\/td><td style=\"vertical-align:top\">10.71<\/td><td>189.05, 190.05, 191.10, 192.10 <\/td><td>10<\/td><\/tr><tr><td style=\"vertical-align:top\">8<\/td><td style=\"vertical-align:top\">11.37<\/td><td>200.10, 201.10, 202.10, 203.05 <\/td><td>10<\/td><\/tr><tr><td style=\"vertical-align:top\">9<\/td><td style=\"vertical-align:top\">11.81<\/td><td>200.10, 201.05, 202.05, 203.05 <\/td><td>10<\/td><\/tr><tr><td style=\"vertical-align:top\">10<\/td><td style=\"vertical-align:top\">12.84<\/td><td>114.00, 120.00, 226.10, 227.10, 228.10, 229.10, 240.10 <\/td><td>10<\/td><\/tr><tr><td style=\"vertical-align:top\">11<\/td><td style=\"vertical-align:top\">14.44<\/td><td>126.00, 132.00, 250.10, 252.10, 253.10, 264.00 <\/td><td>10<\/td><\/tr><tr><td style=\"vertical-align:top\">12<\/td><td style=\"vertical-align:top\">15.51<\/td><td>126.00, 132.00, 250.05, 252.05, 253.05, 264.00 <\/td><td>10<\/td><\/tr><tr><td style=\"vertical-align:top\">13<\/td><td style=\"vertical-align:top\">16.95<\/td><td>137.95, 139.00, 274.05, 276.10, 277.10, 278.10, 279.10 <\/td><td>10<\/td><\/tr><tr><td style=\"vertical-align:top\">14<\/td><td style=\"vertical-align:top\">18.10<\/td><td>138.00, 274.05, 276.10, 277.10 <\/td><td>10<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Type:<\/th><td>Extractor <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Extractor Lens:<\/th><td>6 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>330 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Quad Temp.:<\/th><td>150 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>DFTPP <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890B GC &amp; 5977A MSD<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>NIST SRM 1597a was diluted 5x in dichloromethane. Isotope-labeled IS\/SS are 20 pg on-column. Samples were aliquoted into amber 2 mL, 9 mm short-cap, screw-thread vials (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21143\" rel=\"noopener\">cat.# 21143<\/a>) containing glass Big Mouth inserts (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21782\" rel=\"noopener\">cat.# 21782<\/a>) and sealed with 2.0 mL, 9 mm short-cap, screw-vial closures (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23842\" rel=\"noopener\">cat.# 23842<\/a>).<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>The internal standard and surrogate standard mass on column is 20 pg.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>16623<\/li><li>23303<\/li><li>21143<\/li><li>21782<\/li><li>23842<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>PAH<\/li><li>aromatic<\/li><li>hydrocarbons<\/li><li>polycyclic<\/li><li>semivolatiles-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1606.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Les hydrocarbures aromatiques polycycliques (HAP) sont parmi les compos\u00e9s les plus difficiles \u00e0 s\u00e9parer dans les analyses de semi-volatiles. Les colonnes Rxi-SVOCms permettent une r\u00e9solution optimis\u00e9e de 23 contaminants prioritaires dans les conditions \u00e9tablies ici.<\/p>\n","protected":false},"author":11,"featured_media":6729,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[462],"tags":[],"industries-application":[2208],"post-badge":[],"resource-type":[],"product-library":[2456,2458,2444],"resource-technique":[2316,2320],"ppma_author":[414],"class_list":["post-43497","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-fr","industries-application-environnement","product-library-colonnes-gc","product-library-pieces-de-rechange-pour-injecteur","product-library-produits-pour-la-chromatographie-en-phase-gazeuse","resource-technique-chromatographie-en-phase-gazeuse-gc","resource-technique-spectrometrie-de-masse-ms"],"acf":[],"taxonomy_info":{"category":[{"value":462,"label":"Articles"}],"industries-application":[{"value":2208,"label":"Environnement"}],"product-library":[{"value":2456,"label":"Colonnes GC"},{"value":2458,"label":"Pi\u00e8ces de rechange pour injecteur"},{"value":2444,"label":"Produits pour la chromatographie en phase gazeuse"}],"resource-technique":[{"value":2316,"label":"Chromatographie en phase gazeuse (GC)"},{"value":2320,"label":"Spectrom\u00e9trie de masse (MS)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVFA3822-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":462,"name":"Articles","slug":"articles-fr","term_group":0,"term_taxonomy_id":462,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":462,"category_count":511,"category_description":"","cat_name":"Articles","category_nicename":"articles-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43497","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=43497"}],"version-history":[{"count":14,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43497\/revisions"}],"predecessor-version":[{"id":79020,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43497\/revisions\/79020"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/6729"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=43497"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=43497"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=43497"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=43497"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=43497"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=43497"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=43497"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=43497"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=43497"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}