{"id":43511,"date":"2020-11-01T13:30:00","date_gmt":"2020-11-01T13:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/sept-methodes-epa-sur-un-kit-de-colonne-avec-un-micro-ecd\/"},"modified":"2026-01-28T21:50:17","modified_gmt":"2026-01-28T21:50:17","slug":"sept-methodes-epa-sur-un-kit-de-colonne-avec-un-micro-ecd","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/articles-fr\/evss1013-fr\/sept-methodes-epa-sur-un-kit-de-colonne-avec-un-micro-ecd","title":{"rendered":"Sept m\u00e9thodes EPA sur un kit de colonne avec un micro-ECD"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Analysez les pesticides, PCB , les herbicides et bien plus sur un seul kit de colonnes Rtx-CLPesticides : utilisation d\u2019un micro-ECD et d\u2019une analyse \u00e0 double colonne.<\/h2>\n\n\n\n<p>Obtenez des s\u00e9parations rapides sans sacrifier la r\u00e9solution en utilisant les colonnes exclusives Restek Rtx-CLPesticides et Rtx-CLPesticides 2 pour de multiples m\u00e9thodes environnementales. Au lieu de changer de colonne entre 2 analyses GC-ECD, vous pouvez gagner du temps en analysant les pesticides chlor\u00e9s, les PCB, les herbicides et d\u2019autres compos\u00e9s halog\u00e9n\u00e9s sur un duo de colonnes \u00e0 l\u2019aide d\u2019une analyse \u00e0 double colonne et d\u2019un micro-ECD Agilent.<\/p>\n\n\n\n<p>Comme illustr\u00e9 ici, les colonnes Rtx-CLPesticides et Rtx-CLPesticides2 ont une selectivit\u00e9 unique et sont id\u00e9ales pour diff\u00e9rentes m\u00e9thodes analytiques en GC-ECD.<\/p>\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<thead>\n<tr style=\"vertical-align: top;\">\n<th><strong>Liste des m\u00e9thodes<br \/>par compos\u00e9<\/strong><\/th>\n<th><strong>Paire de colonnes<\/strong><\/th>\n<th><strong>Temps d&#8217;analyse<br \/>(min)<\/strong><\/th>\n<th><strong>Co\u00e9lutions<\/strong><\/th>\n<th><strong>Avantage Restek<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr style=\"vertical-align: top;\">\n<th rowspan=\"3\"><a href=\"https:\/\/www.restek.com\/global\/fr\/articles\/method-8081B-organochlorine-pesticides-analysis-by-GC\/\" target=\"_blank\" rel=\"noopener\"><strong>8081B<\/strong><\/a><br \/><a href=\"https:\/\/discover.restek.com\/articles\/evar4498\/method-8081b-organochlorine-pesticides-analysis-by-gc\"><strong>(Pesticides<br \/>organochlor\u00e9s)<\/strong><\/a><\/th>\n<td>Rtx-CLPesticides \/<br \/>Rtx-CLPesticides2<\/td>\n<td>7 \/ 7<\/td>\n<td>0 \/ 0<\/td>\n<td rowspan=\"3\">\u2022 Meilleure productivit\u00e9 avec des analyses en 7 min et une s\u00e9paration \u00e0 la ligne de base.<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<td>Concurrent A<br \/>colonne 1 \/ colonne 2<\/td>\n<td>7 \/ 8<\/td>\n<td>0 \/ 1<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<td>Concurrent B<br \/>colonne 1 \/ colonne 2<\/td>\n<td>10 \/ 9<\/td>\n<td>0 \/ 0<\/td>\n<\/tr>\n<tr>\n<th colspan=\"5\">\u00a0<\/th>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<th rowspan=\"3\"><a href=\"https:\/\/discover.restek.com\/articles\/evar4500\/method-8081b-organochlorine-pesticides-analysis-by-gc-extended\"><strong>8081B (\u00e9tendu)<\/strong><strong>(Pesticides<br \/>organochlor\u00e9s)<\/strong><\/a><\/th>\n<td>Rtx-CLPesticides \/<br \/>Rtx-CLPesticides2<\/td>\n<td>24 \/ 23<\/td>\n<td>1 \/ 2<\/td>\n<td rowspan=\"3\">\n<p>\u2022 Meilleur \u00e9quilibre entre la rapidit\u00e9 et la s\u00e9lectivit\u00e9.<\/p>\n<p>\u2022 Tous les compos\u00e9s sont s\u00e9par\u00e9s sur au moins une colonne.<\/p>\n<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<td>Concurrent A<br \/>colonne 1 \/ colonne 2<\/td>\n<td>27 \/ 29<\/td>\n<td>0 \/ 3<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<td>Concurrent B<br \/>colonne 1 \/ colonne 2<\/td>\n<td>NDP \/ 16<\/td>\n<td>NDP \/ 3<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<th colspan=\"5\">\u00a0<\/th>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<th rowspan=\"3\"><a href=\"https:\/\/discover.restek.com\/articles\/evar4502\/method-8082a-polychlorinated-biphenyls-pcbs-analysis-by-gc\"><strong>8082A<br \/>(<\/strong><strong>polychlorobiph\u00e9nyles [PCBs], Aroclors)<\/strong><\/a><\/th>\n<td>Rtx-CLPesticides \/<br \/>Rtx-CLPesticides2<\/td>\n<td>7 \/ 7<\/td>\n<td>n\/a<\/td>\n<td rowspan=\"3\">\u2022 Analyse rapide des PCB.<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<td>Concurrent A<br \/>colonne 1 \/ colonne 2<\/td>\n<td>6 \/ 7<\/td>\n<td>n\/a<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<td>Concurrent B<br \/>colonne 1 \/ colonne 2<\/td>\n<td>24 \/ 21<\/td>\n<td>n\/a<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<th colspan=\"5\">\u00a0<\/th>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<th rowspan=\"3\"><a href=\"https:\/\/discover.restek.com\/articles\/evar4501\/method-8151a-chlorinated-herbicides-analysis-by-gc-using-methylation-or-pentafluorobenzylation-derivatization\"><strong>8151A<br \/>(<\/strong><strong>Herbicides chlor\u00e9s)<\/strong><\/a><\/th>\n<td>Rtx-CLPesticides \/<br \/>Rtx-CLPesticides2<\/td>\n<td>13 \/ 13<\/td>\n<td>1 \/ 0<\/td>\n<td rowspan=\"3\">\u2022 Une plus grande variation des ordres d&#8217;\u00e9lution am\u00e9liore la confiance dans les r\u00e9sultats de confirmation.<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<td>Concurrent A<br \/>colonne 1 \/ colonne 2<\/td>\n<td>13 \/ 13<\/td>\n<td>0 \/ 0<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<td>Concurrent B<br \/>colonne 1 \/ colonne 2<\/td>\n<td>16 \/ 15<\/td>\n<td>1 \/ 1<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<th colspan=\"5\">\u00a0<\/th>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<th rowspan=\"3\"><a href=\"https:\/\/discover.restek.com\/articles\/evar4499\/method-504-1-edb-dbcp-and-123tcp-analysis-in-water-by-microextraction-and-gc\"><strong>504.1<br \/>(EDB, DBCP, TCP)<\/strong><\/a><\/th>\n<td>Rtx-CLPesticides \/<br \/>Rtx-CLPesticides2<\/td>\n<td>6 \/ 6<\/td>\n<td>0 \/ 0<\/td>\n<td rowspan=\"3\">\u2022 S\u00e9paration fiable des analytes et des interf\u00e9rences des trihalom\u00e9thanes.<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<td>Concurrent A<br \/>colonne 1 \/ colonne 2<\/td>\n<td>6 \/ 6<\/td>\n<td>0 \/ 0<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<td>Concurrent B<br \/>colonne 1 \/ colonne 2<\/td>\n<td>NDP<\/td>\n<td>NDP<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<th colspan=\"5\">\u00a0<\/th>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<th rowspan=\"3\"><a href=\"http:\/\/Method 505: Analysis of Organohalide Pesticides\" data-wplink-url-error=\"true\"><strong>505<br \/>(Pesticides organohalog\u00e9n\u00e9s)<\/strong><\/a><\/th>\n<td>Rtx-CLPesticides \/<br \/>Rtx-CLPesticides2<\/td>\n<td>18 \/ 18.5<\/td>\n<td>1 \/ 1<\/td>\n<td rowspan=\"3\">\u2022 Tous les compos\u00e9s sont s\u00e9par\u00e9s sur au moins une colonne.<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<td>Concurrent A<br \/>colonne 1 \/ colonne 2<\/td>\n<td>14 \/ 14<\/td>\n<td>0 \/ 1<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<td>Concurrent B<br \/>colonne 1 \/ colonne 2<\/td>\n<td>35 \/ 36<\/td>\n<td>1 \/ 2<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<th colspan=\"5\">\u00a0<\/th>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<th rowspan=\"3\"><a href=\"https:\/\/discover.restek.com\/articles\/evar4503\/method-508-1-determination-of-chlorinated-pesticides-and-herbicides-analysis-by-liquid-solid-extraction-and-electron-capture-gc\"><strong>508.1<br \/>(Pesticides organo-chlor\u00e9s, herbicides, comp. organohalog\u00e9n\u00e9s)<\/strong><\/a><br \/><strong><br \/><\/strong><\/th>\n<td>Competitor A<br \/>column 1 \/ column 2<\/td>\n<td>21 \/ 23<\/td>\n<td>0 \/ 3<\/td>\n<td rowspan=\"3\">\u2022 Bon \u00e9quilibre entre la rapidit\u00e9 et la r\u00e9solution.<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<td>Concurrent A<br \/>colonne 1 \/ colonne 2<\/td>\n<td>21 \/ 23<\/td>\n<td>0 \/ 3<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<td>Concurrent B<br \/>colonne 1 \/ colonne 2<\/td>\n<td>18 \/ 17<\/td>\n<td>2 \/ 4<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<th colspan=\"5\">\u00a0<\/th>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<th rowspan=\"3\"><a href=\"https:\/\/discover.restek.com\/articles\/evar4505\/method-552-2-determination-of-haloacetic-acids-and-dalapon-analysis-in-drinking-water-by-ion-exchange-liquid-solid-extraction-and-gc-with-an-electron-capture-detector\"><strong>552.2<br \/>(Acide haloac\u00e9tique, dalapon)<\/strong><\/a><br \/><strong><br \/><\/strong><\/th>\n<td>Rtx-CLPesticides \/<br \/>Rtx-CLPesticides2<\/td>\n<td>12 \/ 12<\/td>\n<td>0 \/ 0<\/td>\n<td rowspan=\"3\">\u2022 Absence de co\u00e9lution : r\u00e9sultat pr\u00e9cis pour les compos\u00e9s co\u00e9lu\u00e9s sur les autres colonnes<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<td>Concurrent A<br \/>colonne 1 \/ colonne 2<\/td>\n<td>8 \/ 9<\/td>\n<td>1 \/ 1<\/td>\n<\/tr>\n<tr style=\"vertical-align: top;\">\n<td>Concurrent B<br \/>colonne 1 \/ colonne 2<\/td>\n<td>NDP \/ 10<\/td>\n<td>NDP \/ 1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<p>Comparaison avec les donn\u00e9es publi\u00e9es par les concurrents. Toutes les colonnes test\u00e9es avaient un DI de 0,32 mm. DNP = donn\u00e9es non publi\u00e9es.<\/p>\n\n\n\n<p>REMARQUE : Les analyses d\u2019\u00e9chantillons impurs ou d\u00e9riv\u00e9s peuvent provoquer une contamination de la colonne. Restek ne recommande pas d\u2019analyser les \u00e9chantillons contenant des traces de pesticides \u00e0 la suite d&#8217;\u00e9chantillons d\u00e9riv\u00e9s (par exemple, les m\u00e9thodes 8151A et 552.2) sans avoir r\u00e9alis\u00e9 la maintenance de l\u2019injecteur au pr\u00e9alable. Les \u00e9tapes classiques consistent \u00e0 couper l\u2019extr\u00e9mit\u00e9 de la pr\u00e9colonne et \u00e0 changer l\u2019insert d&#8217;injection, le joint, le plancher d\u2019injecteur et le septum.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Obtenez des s\u00e9parations rapides sans sacrifier la r\u00e9solution en utilisant les colonnes exclusives Restek Rtx-CLPesticides et Rtx-CLPesticides 2 pour de multiples m\u00e9thodes environnementales. Au lieu de changer de colonne entre 2 analyses GC-ECD, vous pouvez gagner du temps en analysant les pesticides chlor\u00e9s, les PCB, les herbicides et d\u2019autres compos\u00e9s halog\u00e9n\u00e9s sur un duo de colonnes \u00e0 l\u2019aide d\u2019une analyse \u00e0 double colonne et d\u2019un micro-ECD Agilent. Les colonnes Rtx-CLPesticides et Rtx-CLPesticides2 ont une selectivit\u00e9 unique et sont id\u00e9ales pour diff\u00e9rentes m\u00e9thodes analytiques en GC-ECD.<\/p>\n","protected":false},"author":11,"featured_media":6753,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[462],"tags":[],"industries-application":[2208],"post-badge":[],"resource-type":[],"product-library":[2456,2444],"resource-technique":[2316],"ppma_author":[414],"class_list":["post-43511","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-fr","industries-application-environnement","product-library-colonnes-gc","product-library-produits-pour-la-chromatographie-en-phase-gazeuse","resource-technique-chromatographie-en-phase-gazeuse-gc"],"acf":[],"taxonomy_info":{"category":[{"value":462,"label":"Articles"}],"industries-application":[{"value":2208,"label":"Environnement"}],"product-library":[{"value":2456,"label":"Colonnes GC"},{"value":2444,"label":"Produits pour la chromatographie en phase gazeuse"}],"resource-technique":[{"value":2316,"label":"Chromatographie en phase gazeuse (GC)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVSS1013-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":462,"name":"Articles","slug":"articles-fr","term_group":0,"term_taxonomy_id":462,"taxonomy":"category","description":"","parent":0,"count":465,"filter":"raw","cat_ID":462,"category_count":465,"category_description":"","cat_name":"Articles","category_nicename":"articles-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43511","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=43511"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43511\/revisions"}],"predecessor-version":[{"id":85731,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43511\/revisions\/85731"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/6753"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=43511"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=43511"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=43511"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=43511"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=43511"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=43511"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=43511"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=43511"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=43511"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}