{"id":43515,"date":"2020-12-22T00:00:00","date_gmt":"2020-12-22T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/the-rave-family-of-air-sampling-valves-excellence-is-our-standard\/"},"modified":"2026-01-03T16:12:38","modified_gmt":"2026-01-03T16:12:38","slug":"the-rave-family-of-air-sampling-valves-excellence-is-our-standard","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/articles\/evss2105\/the-rave-family-of-air-sampling-valves-excellence-is-our-standard","title":{"rendered":"The RAVE Family of Air Sampling Valves: Excellence Is Our Standard"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>Proven long life<\/li>\n\n\n\n<li>Leak-free performance<\/li>\n\n\n\n<li>Effortless operation<\/li>\n\n\n\n<li>Enhanced damage resistance<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Our family of Restek Air Valve Excellence valves feature&nbsp;proven long life, leak-free performance (helium leak tested&nbsp;to 1&#215;10-6 mL\/sec), and effortless operation. New, highperformance RAVE+ diaphragm valves\u2014redesigned with&nbsp;advanced features designed for reliability and ease of&nbsp;use\u2014are standard on our full line of SilcoCan, TO-Can, and&nbsp;miniature air sampling canisters. RAVEn diaphragm valves&nbsp;bring the high quality of our original RAVE brand to your&nbsp;Entech air canisters. RAVEqc quick-connect air valves offer an&nbsp;even faster, tool-free means of collecting your sample in the&nbsp;field or analyzing it the lab. RAVEqc quick-connect air valves&nbsp;are ideal for both Restek and Entech air cans.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Available options:<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">All RAVE+, RAVEn, and RAVEqc&nbsp;valves are made in the U.S. from&nbsp;rugged stainless steel and are&nbsp;available with or without Siltek&nbsp;treatment for added inertness. RAVE+ and RAVEn diaphragm&nbsp;valves: choose from 2-port or&nbsp;3-port (for optional gauge)&nbsp;models. Rebuild kits available. RAVEqc quick-connect valves:&nbsp;browse our wide selection of&nbsp;valve and fitting options.<\/td><td rowspan=\"2\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-evss2105-01.jpg\" alt=\"figure-article-evss2105-01.jpg\" width=\"300\" height=\"327\" title=\"-\"><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">RAVE+ Diaphragm Air Valves<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Exclusive polymer-free construction means no sample&nbsp;contamination from off-gassing or target compound loss&nbsp;due to adsorption.<\/li>\n\n\n\n<li>Durable, roller-hardened valve port threads provide&nbsp;superior performance\u2014and every valve is helium leak&nbsp;tested to 1&#215;10-6 mL\/sec.<\/li>\n\n\n\n<li>Rugged, work-hardened, proprietary, all-metal valve seats&nbsp;provide protection against particles that cause leaks.<\/li>\n\n\n\n<li>VOC-free, thread-locking adhesive keeps valve knob&nbsp;securely in place.<\/li>\n\n\n\n<li>Hard-stop design prevents users from overturning the&nbsp;valve and locking it open.<\/li>\n\n\n\n<li>Effortless operation\u2014easily finger turn to achieve full&nbsp;valve closure (only 10 in-lb).<\/li>\n\n\n\n<li>Rugged, 100% stainless-steel construction ensures long&nbsp;service life.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Turn to your trusted partner for air sampling and&nbsp;chromatography. Order Restek Air Valve Excellence for&nbsp;your Restek or Entech air sampling canisters today.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Excellence Is Our Standard \u2013 RAVE+ Diaphragm&nbsp;Valves Are Standard on All Restek Air Canisters<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">If you use a traditional diaphragm valve, RAVE+ valves are now standard on our full&nbsp;line of SilcoCan, TO-Can, and miniature air sampling canisters. RAVE+ valves are&nbsp;also available separately for upgrading existing air canisters to improve reliability and&nbsp;performance. Choose RAVE+ valves to upgrade your Restek canisters or RAVEn valves&nbsp;to upgrade your Entech canisters.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">RAVEqc Quick-Connect Air Valves<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Simplify your workflow<\/strong>\u2014tool-free&nbsp;design makes it fast and easy for anyone&nbsp;to make consistent, quality connections.<\/li>\n\n\n\n<li><strong>Extend air canister and valve lifetime<\/strong>\u2014no wrenches means no overtightening or&nbsp;cross-threading damage.<\/li>\n\n\n\n<li><strong>Stand-alone or supporting roles<\/strong>\u2014use&nbsp;alone or pair with a bellows\/diaphragm&nbsp;valve for the ultimate in sample security&nbsp;and convenience.<\/li>\n\n\n\n<li>Compatible with Entech Micro-QT valves.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>CHECK FLOW STATUS&nbsp;AT A GLANCE:<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-evss2105-02.jpg\" alt=\"figure-article-evss2105-02.jpg\" width=\"900\" height=\"700\" title=\"-\"><\/td><td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-evss2105-03.jpg\" alt=\"figure-article-evss2105-03.jpg\" width=\"900\" height=\"700\" title=\"-\"><\/td><\/tr><tr><td>If the parts are&nbsp;connected, the&nbsp;valve is open.<\/td><td>If they\u2019re apart,&nbsp;it\u2019s closed.*<\/td><\/tr><tr><td colspan=\"2\">* Open-position valves also available.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Save Time with RAVEqc Quick-Connect Air Valves<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">In addition to being tool-free, easy to use, and reducing the risk of damage, RAVEqc quick-connect air valves&nbsp;make connecting and disconnecting to other devices faster than with compression fittings. As shown in Table&nbsp;I, a skilled user working confidently and quickly was able to attach 12 canisters with RAVE diaphragm valves to&nbsp;an oven in about 5 minutes. That same user was able to get 12 canisters with RAVEqc quick-connect air valves&nbsp;hooked up in half the time!<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> Connect and disconnect your air canisters in half the time with RAVEqc quick-connect air valves.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Valve<\/strong><\/td><td><strong>Attach (sec)<\/strong><\/td><td><strong>Detach (sec)<\/strong><\/td><td><strong>Total (sec)<\/strong><\/td><td><strong>x12 Canister (sec)<\/strong><\/td><td><strong>Oven Load\/<\/strong><br><strong>Unload (min)<\/strong><\/td><\/tr><tr><td>RAVEqc 1<\/td><td>8.32<\/td><td>5.45<\/td><td>13.77<\/td><td>165.2<\/td><td>&nbsp;<\/td><\/tr><tr><td>RAVEqc 2<\/td><td>6.56<\/td><td>5.22<\/td><td>11.78<\/td><td>141.4<\/td><td>&nbsp;<\/td><\/tr><tr><td>RAVEqc 3<\/td><td>6.65<\/td><td>4.59<\/td><td>11.24<\/td><td>134.9<\/td><td>&nbsp;<\/td><\/tr><tr><td>RAVEqc Avg.<\/td><td>7.18<\/td><td>5.09<\/td><td>12.26<\/td><td>147.2<\/td><td><strong>2.45<\/strong><\/td><\/tr><tr><td>&nbsp;<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><td>&nbsp;<\/td><\/tr><tr><td>RAVE 1<\/td><td>13.70<\/td><td>14.18<\/td><td>27.88<\/td><td>334.6<\/td><td>&nbsp;<\/td><\/tr><tr><td>RAVE 2<\/td><td>12.63<\/td><td>12.25<\/td><td>24.88<\/td><td>298.6<\/td><td>&nbsp;<\/td><\/tr><tr><td>RAVE 3<\/td><td>13.03<\/td><td>10.63<\/td><td>23.66<\/td><td>283.9<\/td><td>&nbsp;<\/td><\/tr><tr><td>RAVE Avg.<\/td><td>13.12<\/td><td>12.35<\/td><td>25.47<\/td><td>305.7<\/td><td><strong>5.09<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Simplify Your Workflow with Tool-Free RAVEqc&nbsp;Quick-Connect Air Valves<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Whether you need to replace your existing bellows\/diaphragm valves or want the&nbsp;extra sample security of using two valves in tandem, RAVEqc quick-connect air&nbsp;valves are a tool-free, easy-to-use option that will make air sampling and analysis&nbsp;much easier. There\u2019s never any question about whether or not the valve is open&nbsp;because you can tell at a glance. If the male and female valves are connected, the&nbsp;flow path is open. If they aren\u2019t, it\u2019s closed. Open-position valves also available.*<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">*&nbsp;Open-position option available to prevent vacuum\/pressure from being trapped by the valve when desired (e.g., when using a vacuum\/pressure gauge). High flow facilitates use with canister-cleaning ovens.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Which RAVEqc Quick-Connect Air Valves Do I Need?<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Use these guidelines to select the perfect RAVEqc quick-connect air valve for your application!<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Every RAVEqc quick-connect air valve has two halves (valve end and fitting end). Match each end to the&nbsp;opposite gender valve or fitting. For fittings, also be sure to match the connection dimension.<br><em>Examples:<\/em><ul><li>To connect directly to a Restek air can with a tube stub&nbsp;\u00bc&#8221; female compression fitting, use a bracket and any&nbsp;RAVEqc air valve with a \u00bc\u201d male compression fitting.<\/li><\/ul><img loading=\"lazy\" decoding=\"async\" width=\"1800\" height=\"549\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-evss2105-04.jpg\" alt=\"figure-article-evss2105-04.jpg\" title=\"-\"><ul><li>To connect to the \u00bc&#8221; male compression fitting on a diaphragm valve that is installed on an air canister, use a&nbsp;RAVEqc quick-connect air valve with a tube end fitting.<\/li><\/ul><img loading=\"lazy\" decoding=\"async\" width=\"1800\" height=\"549\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-evss2105-05.jpg\" alt=\"figure-article-evss2105-05.jpg\" title=\"-\"><\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li>For tube end fittings, choose length based on the clearances you need for installation.<\/li>\n\n\n\n<li>For reactive compounds, use Siltek-treated valves for a highly inert sample path.<\/li>\n\n\n\n<li>Male valves are less expensive than female valves, so use them on your most numerous devices (e.g., air canisters,&nbsp;not cleaning ovens).<\/li>\n<\/ul>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Related Products<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27325\">                                R\u00e9f. 27325                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Vanne \u00e0 membrane 1\/4&quot; RAVE+ (2 voies), acier inoxydable, pour canister Restek<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27325\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27376\">                                R\u00e9f. 27376                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Vanne \u00e0 membrane 1\/4&quot; RAVEn (2 voies), acier inoxydable, pour canister Entech<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27376\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27341\">                                R\u00e9f. 27341                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Vanne Quick-Connect RAVEqc femelle avec raccord m\u00e2le 1\/16&quot;<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27341\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27375\">                                R\u00e9f. 27375                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Platine de maintien RAVEqc pour montage sur les canisters Restek<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27375\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27292\">                                R\u00e9f. 27292                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raccord RAVE+ : acier inoxydable, fritt\u00e9 de 2 \u00b5m et support<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27292\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Restek Air Valve Excellence valves feature proven long life, leak-free performance, and effortless operation.<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[7],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2371,2382],"resource-technique":[2293],"ppma_author":[414],"class_list":["post-43515","post","type-post","status-publish","format-standard","hentry","category-articles","product-library-air-gas-sampling-products","product-library-air-sampling-bottles-valves","resource-technique-air-sampling"],"acf":[],"taxonomy_info":{"category":[{"value":7,"label":"Articles"}],"product-library":[{"value":2371,"label":"Air &amp; Gas Sampling Products"},{"value":2382,"label":"Air Sampling Bottles &amp; Valves"}],"resource-technique":[{"value":2293,"label":"Air Sampling"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":7,"category_count":510,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43515","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=43515"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43515\/revisions"}],"predecessor-version":[{"id":79390,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43515\/revisions\/79390"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=43515"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=43515"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=43515"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=43515"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=43515"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=43515"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=43515"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=43515"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=43515"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}