{"id":43528,"date":"2022-05-30T14:30:00","date_gmt":"2022-05-30T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/identifiez-les-composes-semi-volatils-grace-a-la-fiabilite-et-a-la-robustesse-de-nos-colonnes-rxi-svocms\/"},"modified":"2026-01-28T14:39:07","modified_gmt":"2026-01-28T14:39:07","slug":"identifiez-les-composes-semi-volatils-grace-a-la-fiabilite-et-a-la-robustesse-de-nos-colonnes-rxi-svocms","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/articles-fr\/evss3820-fr\/identifiez-les-composes-semi-volatils-grace-a-la-fiabilite-et-a-la-robustesse-de-nos-colonnes-rxi-svocms","title":{"rendered":"Identifiez les compos\u00e9s semi-volatils gr\u00e2ce \u00e0 la fiabilit\u00e9 et \u00e0 la robustesse de nos colonnes Rxi-SVOCms"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>Exceptionnelle inertie garantissant des \u00e9talonnages r\u00e9ussis et une productivit\u00e9 maximale.<\/li>\n\n\n\n<li>Excellente r\u00e9solution des paires critiques pour plus de pr\u00e9cision.<\/li>\n\n\n\n<li>Performances constantes d\u2019une colonne \u00e0 l\u2019autre.<\/li>\n\n\n\n<li>Grande long\u00e9vit\u00e9.<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-border-color has-text-color has-link-color wp-elements-746a89d13185a18e93d4dfd8399d4c01 is-layout-flow wp-block-column-is-layout-flow\" style=\"border-color:#e67e23;border-width:1px;color:#e67e23;padding-top:10px;padding-right:20px;padding-bottom:10px;padding-left:20px;flex-basis:75%\">\n<p class=\"wp-block-paragraph\"><strong><em>Notre colonne GC Rxi-SVOCms a \u00e9t\u00e9 d\u00e9sign\u00e9e meilleur nouveau produit de l&#8217;ann\u00e9e (&#8220;Best New Analytical Science Product&#8221;) dans le cadre des SelectScience Scientists&#8217; Choice Awards.&nbsp;<\/em><\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Sp\u00e9cialement con\u00e7ues pour les analyses de compos\u00e9s semi-volatils, les nouvelles colonnes Restek Rxi-SVOCms garantissent des performances constantes qui pr\u00e9servent l\u2019\u00e9talonnage de la colonne afin de prolonger les temps d\u2019analyse au maximum avant de devoir r\u00e9\u00e9talonner l\u2019instrument ou remplacer la colonne. Gr\u00e2ce \u00e0 leur nouveau polym\u00e8re et \u00e0 leur nouvelle d\u00e9sactivation, ces colonnes tr\u00e8s inertes \u00e0 la s\u00e9lectivit\u00e9 \u00e9troitement contr\u00f4l\u00e9e offrent des performances exceptionnelles pour une grande vari\u00e9t\u00e9 d\u2019analytes (acides, basiques et neutres).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Les colonnes Rxi-SVOCms sont sp\u00e9cifiquement ajust\u00e9es pour am\u00e9liorer la forme des pics de certains COSV difficiles, comme le pentachloroph\u00e9nol, la pyridine et la benzidine, et pour garantir une r\u00e9solution optimale des hydrocarbures aromatiques polycycliques (HAP) difficiles \u00e0 s\u00e9parer. La Figure 1 montre que les analytes r\u00e9actifs les plus probl\u00e9matiques pr\u00e9sentent des pics gaussiens. En outre, une excellente r\u00e9solution (R \u2265 85 %) est obtenue pour le benzo(b)fluoranth\u00e8ne et le benzo(k)fluoranth\u00e8ne, deux HAP isobares qui doivent \u00eatre s\u00e9par\u00e9s par la chromatographie, ainsi que pour l\u2019indeno(1,2,3-c,d)pyr\u00e8ne et le dibenz[a,h]anthrac\u00e8ne.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour les chimistes du secteur environnemental qui sont limit\u00e9s par les performances variables des colonnes, les \u00e9checs d\u2019\u00e9talonnage fr\u00e9quents et les dur\u00e9es de vie courtes, le passage aux robustes colonnes Rxi-SVOCms peut garantir que les exigences relatives aux donn\u00e9es sont respect\u00e9es plus longtemps, et que les temps d\u2019arr\u00eat sont r\u00e9duits au minimum.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1 :<\/strong>\u00a0Les colonnes Rxi-SVOCms offrent des performances chromatographiques exceptionnelles. Elles produisent \u00e0 chaque fois des pics fins et une bonne r\u00e9solution, m\u00eame pour les compos\u00e9s probl\u00e9matiques. L\u2019injection &#8220;split&#8221; est recommand\u00e9e, si possible, car elle r\u00e9duit la contamination dans l\u2019injecteur et lors du transfert de l\u2019\u00e9chantillon vers la colonne analytique.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1604.png\" alt=\"Semivolatiles Analysis on Rxi-SVOCms\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1604<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-4 col-12 peak-33\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (IS) 1,4-Dioxane-d8\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/17647-74-4\/(IS) 1,4-Dioxane-d8\" target=\"_blank\" rel=\"noopener\">(IS) 1,4-Dioxane-d8<\/a><\/td><td class=\"oth\">1.87<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\">&lt;a class=&quot;cmpd_link&quot; title=&quot;View compound information for <i>N<\/i>-Nitrosodimethylamine&#8221; title=&#8221;View compound information for <i>N<\/i>-Nitrosodimethylamine&#8221; href=&#8221;https:\/\/ez.restek.com\/compound\/view\/en\/62-75-9\/<i>N-Nitrosodimethylamine&#8221;&gt;<i>N<\/i>-Nitrosodimethylamine<\/a><\/td><td class=\"oth\">2.00<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyridine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110-86-1\/Pyridine\" target=\"_blank\" rel=\"noopener\">Pyridine<\/a><\/td><td class=\"oth\">2.03<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (SS) 2-Fluorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/367-12-4\/(SS) 2-Fluorophenol\" target=\"_blank\" rel=\"noopener\">(SS) 2-Fluorophenol<\/a><\/td><td class=\"oth\">2.67<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (SS) Phenol-d6\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13127-88-3\/(SS) Phenol-d6\" target=\"_blank\" rel=\"noopener\">(SS) Phenol-d6<\/a><\/td><td class=\"oth\">3.29<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-95-2\/Phenol\" target=\"_blank\" rel=\"noopener\">Phenol<\/a><\/td><td class=\"oth\">3.30<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62-53-3\/Aniline\" target=\"_blank\" rel=\"noopener\">Aniline<\/a><\/td><td class=\"oth\">3.36<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bis(2-chloroethyl) ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111-44-4\/Bis(2-chloroethyl) ether\" target=\"_blank\" rel=\"noopener\">Bis(2-chloroethyl) ether<\/a><\/td><td class=\"oth\">3.40<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Chlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-57-8\/2-Chlorophenol\" target=\"_blank\" rel=\"noopener\">2-Chlorophenol<\/a><\/td><td class=\"oth\">3.46<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,3-Dichlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/541-73-1\/1,3-Dichlorobenzene\" target=\"_blank\" rel=\"noopener\">1,3-Dichlorobenzene<\/a><\/td><td class=\"oth\">3.59<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (IS) 1,4-Dichlorobenzene-D4\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3855-82-1\/(IS) 1,4-Dichlorobenzene-D4\" target=\"_blank\" rel=\"noopener\">(IS) 1,4-Dichlorobenzene-D4<\/a><\/td><td class=\"oth\">3.63<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Dichlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-46-7\/1,4-Dichlorobenzene\" target=\"_blank\" rel=\"noopener\">1,4-Dichlorobenzene<\/a><\/td><td class=\"oth\">3.65<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzyl alcohol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-51-6\/Benzyl alcohol\" target=\"_blank\" rel=\"noopener\">Benzyl alcohol<\/a><\/td><td class=\"oth\">3.72<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,2-Dichlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-50-1\/1,2-Dichlorobenzene\" target=\"_blank\" rel=\"noopener\">1,2-Dichlorobenzene<\/a><\/td><td class=\"oth\">3.78<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Methylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-48-7\/2-Methylphenol\" target=\"_blank\" rel=\"noopener\">2-Methylphenol<\/a><\/td><td class=\"oth\">3.80<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bis(2-Chloroisopropyl)ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-60-1\/Bis(2-Chloroisopropyl)ether\" target=\"_blank\" rel=\"noopener\">Bis(2-Chloroisopropyl)ether<\/a><\/td><td class=\"oth\">3.84<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Methylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-44-5\/4-Methylphenol\" target=\"_blank\" rel=\"noopener\">4-Methylphenol<\/a><\/td><td class=\"oth\">3.93<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3-Methylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-39-4\/3-Methylphenol\" target=\"_blank\" rel=\"noopener\">3-Methylphenol<\/a><\/td><td class=\"oth\">3.93<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\">&lt;a class=&quot;cmpd_link&quot; title=&quot;View compound information for <i>N<\/i>-Nitrosodi-<i>N<\/i>-propylamine&#8221; title=&#8221;View compound information for <i>N<\/i>-Nitrosodi-<i>N<\/i>-propylamine&#8221; href=&#8221;https:\/\/ez.restek.com\/compound\/view\/en\/621-64-7\/<i>N-Nitrosodi-<i>N-propylamine&#8221;&gt;<i>N<\/i>-Nitrosodi-<i>N<\/i>-propylamine<\/a><\/td><td class=\"oth\">3.95<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachloroethane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/67-72-1\/Hexachloroethane\" target=\"_blank\" rel=\"noopener\">Hexachloroethane<\/a><\/td><td class=\"oth\">4.07<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (SS) Nitrobenzene-D5\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/4165-60-0\/(SS) Nitrobenzene-D5\" target=\"_blank\" rel=\"noopener\">(SS) Nitrobenzene-D5<\/a><\/td><td class=\"oth\">4.10<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/98-95-3\/Nitrobenzene\" target=\"_blank\" rel=\"noopener\">Nitrobenzene<\/a><\/td><td class=\"oth\">4.11<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isophorone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78-59-1\/Isophorone\" target=\"_blank\" rel=\"noopener\">Isophorone<\/a><\/td><td class=\"oth\">4.32<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Nitrophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88-75-5\/2-Nitrophenol\" target=\"_blank\" rel=\"noopener\">2-Nitrophenol<\/a><\/td><td class=\"oth\">4.40<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dimethylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/105-67-9\/2,4-Dimethylphenol\" target=\"_blank\" rel=\"noopener\">2,4-Dimethylphenol<\/a><\/td><td class=\"oth\">4.42<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzoic acid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/65-85-0\/Benzoic acid\" target=\"_blank\" rel=\"noopener\">Benzoic acid<\/a><\/td><td class=\"oth\">4.46<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bis(2-chloroethoxy)methane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111-91-1\/Bis(2-chloroethoxy)methane\" target=\"_blank\" rel=\"noopener\">Bis(2-chloroethoxy)methane<\/a><\/td><td class=\"oth\">4.51<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dichlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-83-2\/2,4-Dichlorophenol\" target=\"_blank\" rel=\"noopener\">2,4-Dichlorophenol<\/a><\/td><td class=\"oth\">4.61<\/td><\/tr>\n<tr><td class=\"num\">29.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,2,4-Trichlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-82-1\/1,2,4-Trichlorobenzene\" target=\"_blank\" rel=\"noopener\">1,2,4-Trichlorobenzene<\/a><\/td><td class=\"oth\">4.70<\/td><\/tr>\n<tr><td class=\"num\">30.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (IS) Naphthalene-D8\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1146-65-2\/(IS) Naphthalene-D8\" target=\"_blank\" rel=\"noopener\">(IS) Naphthalene-D8<\/a><\/td><td class=\"oth\">4.76<\/td><\/tr>\n<tr><td class=\"num\">31.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Naphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-20-3\/Naphthalene\" target=\"_blank\" rel=\"noopener\">Naphthalene<\/a><\/td><td class=\"oth\">4.78<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-4 col-12 peak-33\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">32.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Chloroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-47-8\/4-Chloroaniline\" target=\"_blank\" rel=\"noopener\">4-Chloroaniline<\/a><\/td><td class=\"oth\">4.82<\/td><\/tr>\n<tr><td class=\"num\">33.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachlorobutadiene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/87-68-3\/Hexachlorobutadiene\" target=\"_blank\" rel=\"noopener\">Hexachlorobutadiene<\/a><\/td><td class=\"oth\">4.89<\/td><\/tr>\n<tr><td class=\"num\">34.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Chloro-3-methylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59-50-7\/4-Chloro-3-methylphenol\" target=\"_blank\" rel=\"noopener\">4-Chloro-3-methylphenol<\/a><\/td><td class=\"oth\">5.26<\/td><\/tr>\n<tr><td class=\"num\">35.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Methylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-57-6\/2-Methylnaphthalene\" target=\"_blank\" rel=\"noopener\">2-Methylnaphthalene<\/a><\/td><td class=\"oth\">5.43<\/td><\/tr>\n<tr><td class=\"num\">36.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Methylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90-12-0\/1-Methylnaphthalene\" target=\"_blank\" rel=\"noopener\">1-Methylnaphthalene<\/a><\/td><td class=\"oth\">5.53<\/td><\/tr>\n<tr><td class=\"num\">37.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachlorocyclopentadiene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/77-47-4\/Hexachlorocyclopentadiene\" target=\"_blank\" rel=\"noopener\">Hexachlorocyclopentadiene<\/a><\/td><td class=\"oth\">5.59<\/td><\/tr>\n<tr><td class=\"num\">38.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4,6-Trichlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88-06-2\/2,4,6-Trichlorophenol\" target=\"_blank\" rel=\"noopener\">2,4,6-Trichlorophenol<\/a><\/td><td class=\"oth\">5.70<\/td><\/tr>\n<tr><td class=\"num\">39.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4,5-Trichlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-95-4\/2,4,5-Trichlorophenol\" target=\"_blank\" rel=\"noopener\">2,4,5-Trichlorophenol<\/a><\/td><td class=\"oth\">5.73<\/td><\/tr>\n<tr><td class=\"num\">40.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (SS) 2-Fluorobiphenyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/321-60-8\/(SS) 2-Fluorobiphenyl\" target=\"_blank\" rel=\"noopener\">(SS) 2-Fluorobiphenyl<\/a><\/td><td class=\"oth\">5.79<\/td><\/tr>\n<tr><td class=\"num\">41.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Chloronaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-58-7\/2-Chloronaphthalene\" target=\"_blank\" rel=\"noopener\">2-Chloronaphthalene<\/a><\/td><td class=\"oth\">5.91<\/td><\/tr>\n<tr><td class=\"num\">42.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Nitroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88-74-4\/2-Nitroaniline\" target=\"_blank\" rel=\"noopener\">2-Nitroaniline<\/a><\/td><td class=\"oth\">6.00<\/td><\/tr>\n<tr><td class=\"num\">43.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Dinitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-25-4\/1,4-Dinitrobenzene\" target=\"_blank\" rel=\"noopener\">1,4-Dinitrobenzene<\/a><\/td><td class=\"oth\">6.13<\/td><\/tr>\n<tr><td class=\"num\">44.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dimethyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/131-11-3\/Dimethyl phthalate\" target=\"_blank\" rel=\"noopener\">Dimethyl phthalate<\/a><\/td><td class=\"oth\">6.18<\/td><\/tr>\n<tr><td class=\"num\">45.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,3-Dinitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-65-0\/1,3-Dinitrobenzene\" target=\"_blank\" rel=\"noopener\">1,3-Dinitrobenzene<\/a><\/td><td class=\"oth\">6.20<\/td><\/tr>\n<tr><td class=\"num\">46.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,6-Dinitrotoluene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/606-20-2\/2,6-Dinitrotoluene\" target=\"_blank\" rel=\"noopener\">2,6-Dinitrotoluene<\/a><\/td><td class=\"oth\">6.24<\/td><\/tr>\n<tr><td class=\"num\">47.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,2-Dinitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/528-29-0\/1,2-Dinitrobenzene\" target=\"_blank\" rel=\"noopener\">1,2-Dinitrobenzene<\/a><\/td><td class=\"oth\">6.29<\/td><\/tr>\n<tr><td class=\"num\">48.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/208-96-8\/Acenaphthylene\" target=\"_blank\" rel=\"noopener\">Acenaphthylene<\/a><\/td><td class=\"oth\">6.31<\/td><\/tr>\n<tr><td class=\"num\">49.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3-Nitroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-09-2\/3-Nitroaniline\" target=\"_blank\" rel=\"noopener\">3-Nitroaniline<\/a><\/td><td class=\"oth\">6.40<\/td><\/tr>\n<tr><td class=\"num\">50.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (IS) Acenaphthene-D10\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/15067-26-2\/(IS) Acenaphthene-D10\" target=\"_blank\" rel=\"noopener\">(IS) Acenaphthene-D10<\/a><\/td><td class=\"oth\">6.45<\/td><\/tr>\n<tr><td class=\"num\">51.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/83-32-9\/Acenaphthene\" target=\"_blank\" rel=\"noopener\">Acenaphthene<\/a><\/td><td class=\"oth\">6.48<\/td><\/tr>\n<tr><td class=\"num\">52.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dinitrophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51-28-5\/2,4-Dinitrophenol\" target=\"_blank\" rel=\"noopener\">2,4-Dinitrophenol<\/a><\/td><td class=\"oth\">6.50<\/td><\/tr>\n<tr><td class=\"num\">53.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Nitrophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-02-7\/4-Nitrophenol\" target=\"_blank\" rel=\"noopener\">4-Nitrophenol<\/a><\/td><td class=\"oth\">6.55<\/td><\/tr>\n<tr><td class=\"num\">54.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dinitrotoluene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/121-14-2\/2,4-Dinitrotoluene\" target=\"_blank\" rel=\"noopener\">2,4-Dinitrotoluene<\/a><\/td><td class=\"oth\">6.63<\/td><\/tr>\n<tr><td class=\"num\">55.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenzofuran\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/132-64-9\/Dibenzofuran\" target=\"_blank\" rel=\"noopener\">Dibenzofuran<\/a><\/td><td class=\"oth\">6.65<\/td><\/tr>\n<tr><td class=\"num\">56.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,3,5,6-Tetrachlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/935-95-5\/2,3,5,6-Tetrachlorophenol\" target=\"_blank\" rel=\"noopener\">2,3,5,6-Tetrachlorophenol<\/a><\/td><td class=\"oth\">6.73<\/td><\/tr>\n<tr><td class=\"num\">57.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,3,4,6-Tetrachlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/58-90-2\/2,3,4,6-Tetrachlorophenol\" target=\"_blank\" rel=\"noopener\">2,3,4,6-Tetrachlorophenol<\/a><\/td><td class=\"oth\">6.77<\/td><\/tr>\n<tr><td class=\"num\">58.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diethyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/84-66-2\/Diethyl phthalate\" target=\"_blank\" rel=\"noopener\">Diethyl phthalate<\/a><\/td><td class=\"oth\">6.88<\/td><\/tr>\n<tr><td class=\"num\">59.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Chlorophenyl phenyl ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7005-72-3\/4-Chlorophenyl phenyl ether\" target=\"_blank\" rel=\"noopener\">4-Chlorophenyl phenyl ether<\/a><\/td><td class=\"oth\">6.99<\/td><\/tr>\n<tr><td class=\"num\">60.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluorene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/86-73-7\/Fluorene\" target=\"_blank\" rel=\"noopener\">Fluorene<\/a><\/td><td class=\"oth\">6.99<\/td><\/tr>\n<tr><td class=\"num\">61.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Nitroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-01-6\/4-Nitroaniline\" target=\"_blank\" rel=\"noopener\">4-Nitroaniline<\/a><\/td><td class=\"oth\">7.00<\/td><\/tr>\n<tr><td class=\"num\">62.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4,6-Dinitro-2-methylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/534-52-1\/4,6-Dinitro-2-methylphenol\" target=\"_blank\" rel=\"noopener\">4,6-Dinitro-2-methylphenol<\/a><\/td><td class=\"oth\">7.03<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-4 col-12 peak-33\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">63.<\/td><td class=\"cmpd\">&lt;a class=&quot;cmpd_link&quot; title=&quot;View compound information for <i>N<\/i>-Nitrosodiphenylamine&#8221; title=&#8221;View compound information for <i>N<\/i>-Nitrosodiphenylamine&#8221; href=&#8221;https:\/\/ez.restek.com\/compound\/view\/en\/86-30-6\/<i>N-Nitrosodiphenylamine&#8221;&gt;<i>N<\/i>-Nitrosodiphenylamine<\/a><\/td><td class=\"oth\">7.10<\/td><\/tr>\n<tr><td class=\"num\">64.<\/td><td class=\"cmpd\">&lt;a class=&quot;cmpd_link&quot; title=&quot;View compound information for <i>N,N<\/i>-Diphenylhydrazine&#8221; title=&#8221;View compound information for <i>N,N<\/i>-Diphenylhydrazine&#8221; href=&#8221;https:\/\/ez.restek.com\/compound\/view\/en\/530-50-7\/<i>N,N-Diphenylhydrazine&#8221;&gt;<i>N,N<\/i>-Diphenylhydrazine<\/a><\/td><td class=\"oth\">7.15<\/td><\/tr>\n<tr><td class=\"num\">65.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (SS) 2,4,6-Tribromophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/118-79-6\/(SS) 2,4,6-Tribromophenol\" target=\"_blank\" rel=\"noopener\">(SS) 2,4,6-Tribromophenol<\/a><\/td><td class=\"oth\">7.23<\/td><\/tr>\n<tr><td class=\"num\">66.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Bromophenyl phenyl ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/101-55-3\/4-Bromophenyl phenyl ether\" target=\"_blank\" rel=\"noopener\">4-Bromophenyl phenyl ether<\/a><\/td><td class=\"oth\">7.47<\/td><\/tr>\n<tr><td class=\"num\">67.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/118-74-1\/Hexachlorobenzene\" target=\"_blank\" rel=\"noopener\">Hexachlorobenzene<\/a><\/td><td class=\"oth\">7.53<\/td><\/tr>\n<tr><td class=\"num\">68.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/87-86-5\/Pentachlorophenol\" target=\"_blank\" rel=\"noopener\">Pentachlorophenol<\/a><\/td><td class=\"oth\">7.72<\/td><\/tr>\n<tr><td class=\"num\">69.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (IS) Phenanthrene-D10\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1517-22-2\/(IS) Phenanthrene-D10\" target=\"_blank\" rel=\"noopener\">(IS) Phenanthrene-D10<\/a><\/td><td class=\"oth\">7.92<\/td><\/tr>\n<tr><td class=\"num\">70.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenanthrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85-01-8\/Phenanthrene\" target=\"_blank\" rel=\"noopener\">Phenanthrene<\/a><\/td><td class=\"oth\">7.94<\/td><\/tr>\n<tr><td class=\"num\">71.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-12-7\/Anthracene\" target=\"_blank\" rel=\"noopener\">Anthracene<\/a><\/td><td class=\"oth\">7.99<\/td><\/tr>\n<tr><td class=\"num\">72.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carbazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/86-74-8\/Carbazole\" target=\"_blank\" rel=\"noopener\">Carbazole<\/a><\/td><td class=\"oth\">8.15<\/td><\/tr>\n<tr><td class=\"num\">73.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for di-n-Butyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/84-74-2\/di-n-Butyl phthalate\" target=\"_blank\" rel=\"noopener\">di-n-Butyl phthalate<\/a><\/td><td class=\"oth\">8.49<\/td><\/tr>\n<tr><td class=\"num\">74.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/206-44-0\/Fluoranthene\" target=\"_blank\" rel=\"noopener\">Fluoranthene<\/a><\/td><td class=\"oth\">9.12<\/td><\/tr>\n<tr><td class=\"num\">75.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92-87-5\/Benzidine\" target=\"_blank\" rel=\"noopener\">Benzidine<\/a><\/td><td class=\"oth\">9.24<\/td><\/tr>\n<tr><td class=\"num\">76.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (SS) Pyrene-D10\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1718-52-1\/(SS) Pyrene-D10\" target=\"_blank\" rel=\"noopener\">(SS) Pyrene-D10<\/a><\/td><td class=\"oth\">9.32<\/td><\/tr>\n<tr><td class=\"num\">77.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/129-00-0\/Pyrene\" target=\"_blank\" rel=\"noopener\">Pyrene<\/a><\/td><td class=\"oth\">9.34<\/td><\/tr>\n<tr><td class=\"num\">78.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (SS) p-Terphenyl-d14\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1718-51-0\/(SS) p-Terphenyl-d14\" target=\"_blank\" rel=\"noopener\">(SS) p-Terphenyl-d14<\/a><\/td><td class=\"oth\">9.49<\/td><\/tr>\n<tr><td class=\"num\">79.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3,3&amp;apos;-Dimethylbenzidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/119-93-7\/3,3&amp;apos;-Dimethylbenzidine\" target=\"_blank\" rel=\"noopener\">3,3&#8242;-Dimethylbenzidine<\/a><\/td><td class=\"oth\">9.98<\/td><\/tr>\n<tr><td class=\"num\">80.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Butyl benzyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85-68-7\/Butyl benzyl phthalate\" target=\"_blank\" rel=\"noopener\">Butyl benzyl phthalate<\/a><\/td><td class=\"oth\">10.00<\/td><\/tr>\n<tr><td class=\"num\">81.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bis(2-ethylhexyl) adipate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/103-23-1\/Bis(2-ethylhexyl) adipate\" target=\"_blank\" rel=\"noopener\">Bis(2-ethylhexyl) adipate<\/a><\/td><td class=\"oth\">10.09<\/td><\/tr>\n<tr><td class=\"num\">82.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3,3&amp;apos;-Dichlorobenzidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-94-1\/3,3&amp;apos;-Dichlorobenzidine\" target=\"_blank\" rel=\"noopener\">3,3&#8242;-Dichlorobenzidine<\/a><\/td><td class=\"oth\">10.62<\/td><\/tr>\n<tr><td class=\"num\">83.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benz[a]anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-55-3\/Benz[a]anthracene\" target=\"_blank\" rel=\"noopener\">Benz[a]anthracene<\/a><\/td><td class=\"oth\">10.66<\/td><\/tr>\n<tr><td class=\"num\">84.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (IS) Chrysene-D12\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1719-03-5\/(IS) Chrysene-D12\" target=\"_blank\" rel=\"noopener\">(IS) Chrysene-D12<\/a><\/td><td class=\"oth\">10.67<\/td><\/tr>\n<tr><td class=\"num\">85.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chrysene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/218-01-9\/Chrysene\" target=\"_blank\" rel=\"noopener\">Chrysene<\/a><\/td><td class=\"oth\">10.71<\/td><\/tr>\n<tr><td class=\"num\">86.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bis(2-ethylhexyl) phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/117-81-7\/Bis(2-ethylhexyl) phthalate\" target=\"_blank\" rel=\"noopener\">Bis(2-ethylhexyl) phthalate<\/a><\/td><td class=\"oth\">10.71<\/td><\/tr>\n<tr><td class=\"num\">87.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Di-n-octyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/117-84-0\/Di-n-octyl phthalate\" target=\"_blank\" rel=\"noopener\">Di-n-octyl phthalate<\/a><\/td><td class=\"oth\">11.68<\/td><\/tr>\n<tr><td class=\"num\">88.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[b]fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/205-99-2\/Benzo[b]fluoranthene\" target=\"_blank\" rel=\"noopener\">Benzo[b]fluoranthene<\/a><\/td><td class=\"oth\">12.30<\/td><\/tr>\n<tr><td class=\"num\">89.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[k]fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/207-08-9\/Benzo[k]fluoranthene\" target=\"_blank\" rel=\"noopener\">Benzo[k]fluoranthene<\/a><\/td><td class=\"oth\">12.34<\/td><\/tr>\n<tr><td class=\"num\">90.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[a]pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-32-8\/Benzo[a]pyrene\" target=\"_blank\" rel=\"noopener\">Benzo[a]pyrene<\/a><\/td><td class=\"oth\">12.89<\/td><\/tr>\n<tr><td class=\"num\">91.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (IS) Perylene-D12\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1520-96-3\/(IS) Perylene-D12\" target=\"_blank\" rel=\"noopener\">(IS) Perylene-D12<\/a><\/td><td class=\"oth\">13.00<\/td><\/tr>\n<tr><td class=\"num\">92.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Indeno[1,2,3-cd]pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/193-39-5\/Indeno[1,2,3-cd]pyrene\" target=\"_blank\" rel=\"noopener\">Indeno[1,2,3-cd]pyrene<\/a><\/td><td class=\"oth\">15.32<\/td><\/tr>\n<tr><td class=\"num\">93.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenz[a,h]anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53-70-3\/Dibenz[a,h]anthracene\" target=\"_blank\" rel=\"noopener\">Dibenz[a,h]anthracene<\/a><\/td><td class=\"oth\">15.40<\/td><\/tr>\n<tr><td class=\"num\">94.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[ghi]perylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/191-24-2\/Benzo[ghi]perylene\" target=\"_blank\" rel=\"noopener\">Benzo[ghi]perylene<\/a><\/td><td class=\"oth\">15.95<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">All compounds are 2 ng on column.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rxi-SVOCms, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/16623\" rel=\"noopener\">cat.# 16623<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>8270 MegaMix standard (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31850\" rel=\"noopener\">cat.# 31850<\/a>)<\/td><\/tr><tr><td><\/td><td>8270 Benzidines mix (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31852\" rel=\"noopener\">cat.# 31852<\/a>)<\/td><\/tr><tr><td><\/td><td>Benzoic acid  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31879\" rel=\"noopener\">cat.# 31879<\/a>)<\/td><\/tr><tr><td><\/td><td>Revised SV internal standard mix (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31886\" rel=\"noopener\">cat.# 31886<\/a>)<\/td><\/tr><tr><td><\/td><td>Revised B\/N surrogate mix (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31888\" rel=\"noopener\">cat.# 31888<\/a>)<\/td><\/tr><tr><td><\/td><td>Acid surrogate mix (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31063\" rel=\"noopener\">cat.# 31063<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Dichloromethane<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>20 \u00b5g\/mL<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 10:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 4.0 mm ID single taper inlet liner with wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23303\" rel=\"noopener\">cat.# 23303<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Split Vent Flow Rate:<\/th><td>12 mL\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>60 &#176;C (hold 0.5 min) to 285 &#176;C at 25 &#176;C\/min to 305 &#176;C at 3 &#176;C\/min to 330 &#176;C at 20 &#176;C\/min (hold 5 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.2 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>Scan<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Scan Program:<\/th><td><\/td><\/tr><tr><td style=\"text-align:left\" colspan=\"2\"><table class=\"conditions_sim\"><thead><tr><th style=\"padding: 0 5px\">Group<\/th><th style=\"padding: 0 5px\">Start Time<br \/>(min)<\/th><th style=\"padding: 0 5px\">Scan Range<br \/>(amu)<\/th><th style=\"padding: 0 5px\">Scan Rate<br \/>(scans\/sec)<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>1.55<\/td><td>35-500<\/td><td>5.9<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Type:<\/th><td>Inert <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Drawout Plate:<\/th><td>6 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>330 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Quad Temp.:<\/th><td>180 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Electron Energy:<\/th><td>70 eV<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>DFTPP <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890A GC &amp; 5975C MSD<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Samples were aliquoted into amber 2 mL, 9 mm short-cap, screw-thread vials (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21143\" rel=\"noopener\">cat.# 21143<\/a>) containing glass Big Mouth inserts (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21782\" rel=\"noopener\">cat.# 21782<\/a>) and sealed with 2.0 mL, 9 mm short-cap, screw-vial closures (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23842\" rel=\"noopener\">cat.# 23842<\/a>).<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31850<\/li><li>31852<\/li><li>31879<\/li><li>31886<\/li><li>31888<\/li><li>31063<\/li><li>16623<\/li><li>23303<\/li><li>21143<\/li><li>21782<\/li><li>23842<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>SVOC<\/li><li>semivolatile<\/li><li>semivolatiles<\/li><li>semivolatiles-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1604.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<h2 class=\"wp-block-heading\">Des \u00e9talonnages stables pour plus de productivit\u00e9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les \u00e9checs d\u2019\u00e9talonnage impliquent une perte de productivit\u00e9, puisque l\u2019analyse d\u2019\u00e9chantillons doit \u00eatre suspendue pendant les longues op\u00e9rations de maintenance et d\u2019\u00e9talonnage. La meilleure inertie des colonnes Rxi-SVOCms contourne ce probl\u00e8me et permet de limiter l\u2019\u00e9cart-type relatif (%RSD) du facteur de r\u00e9ponse moyen \u00e0 seulement 6 % par rapport \u00e0 l\u2019\u00e9talonnage initial de six colonnes, pour tous les compos\u00e9s et toutes les colonnes (Tableau I). Ces \u00e9carts-types relatifs extr\u00eamement faibles et r\u00e9guliers des facteurs de r\u00e9ponse garantissent une long\u00e9vit\u00e9 de l\u2019\u00e9talonnage et permet d\u2019analyser davantage d&#8217;\u00e9chantillons avant de devoir r\u00e9\u00e9talonner. La Figure 2 montre des pics et des temps de r\u00e9tention r\u00e9guliers m\u00eame \u00e0 diff\u00e9rentes concentrations de pyridine et de pentachloroph\u00e9nol, connus comme \u00e9tant des compos\u00e9s probl\u00e9matiques car ils ont tendance \u00e0 produire des tra\u00een\u00e9es de pics et ne respectent souvent pas les crit\u00e8res d\u2019\u00e9talonnage sur les colonnes peu inertes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Tableau I :<\/strong>&nbsp;Des performances stables entra\u00eenent des \u00e9talonnages moins fr\u00e9quents et laissent plus de temps pour analyser les \u00e9chantillons, ce qui am\u00e9liore la productivit\u00e9 du laboratoire. Le vert indique que les \u00e9talonnages initiaux sont r\u00e9ussis (n = 6 colonnes).<\/p>\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr>\n<td><strong>Compos\u00e9<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>Plage d&#8217;\u00e9talonnage (\u00b5g\/ml)<\/strong><\/td>\n<td style=\"text-align: center;\"><strong>\u00c9cart-type relatif<br role=\"presentation\" data-uw-rm-sr=\"\" \/>moyen (%)<br role=\"presentation\" data-uw-rm-sr=\"\" \/>des facteurs de r\u00e9ponse<\/strong><\/td>\n<\/tr>\n<tr>\n<td>N-Nitrosodimethylamine<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.70%<\/td>\n<\/tr>\n<tr>\n<td>Pyridine<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">6.10%<\/td>\n<\/tr>\n<tr>\n<td>(SS) 2-Fluorophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">1.70%<\/td>\n<\/tr>\n<tr>\n<td>(SS) Phenol-d6<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">2.10%<\/td>\n<\/tr>\n<tr>\n<td>Phenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.20%<\/td>\n<\/tr>\n<tr>\n<td>Aniline<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.10%<\/td>\n<\/tr>\n<tr>\n<td>Bis(2-chloroethyl)ether<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">2.40%<\/td>\n<\/tr>\n<tr>\n<td>2-chlorophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">2.80%<\/td>\n<\/tr>\n<tr>\n<td>1,3-dichlorobenzene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">2.60%<\/td>\n<\/tr>\n<tr>\n<td>1,4-Dichlorobenzene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">2.10%<\/td>\n<\/tr>\n<tr>\n<td>Benzyl alcohol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.30%<\/td>\n<\/tr>\n<tr>\n<td>1,2-Dichlorobenzene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">2.70%<\/td>\n<\/tr>\n<tr>\n<td>2-Methylphenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.30%<\/td>\n<\/tr>\n<tr>\n<td>Bis(2-chloroisopropyl)ether<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">2.40%<\/td>\n<\/tr>\n<tr>\n<td>4-Methylphenol\/3-methylphenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.30%<\/td>\n<\/tr>\n<tr>\n<td>N-nitroso-di-<em>n<\/em>-propylamine<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.80%<\/td>\n<\/tr>\n<tr>\n<td>Hexachloroethane<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.00%<\/td>\n<\/tr>\n<tr>\n<td>(SS) Nitrobenzene-D5<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">1.60%<\/td>\n<\/tr>\n<tr>\n<td>Nitrobenzene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">2.60%<\/td>\n<\/tr>\n<tr>\n<td>Isophorone<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.40%<\/td>\n<\/tr>\n<tr>\n<td>2-Nitrophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">7.00%<\/td>\n<\/tr>\n<tr>\n<td>2,4-Dimethylphenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.70%<\/td>\n<\/tr>\n<tr>\n<td>Benzoic acid<\/td>\n<td style=\"text-align: center;\">2.5 &#8211; 120<\/td>\n<td style=\"background-color: #fdc362; text-align: center;\">25.00%<\/td>\n<\/tr>\n<tr>\n<td>Bis(2-chloroethoxy)methane<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.60%<\/td>\n<\/tr>\n<tr>\n<td>2,4-Dichlorophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.10%<\/td>\n<\/tr>\n<tr>\n<td>1,2,4-Trichlorobenzene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">2.80%<\/td>\n<\/tr>\n<tr>\n<td>Naphthalene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.20%<\/td>\n<\/tr>\n<tr>\n<td>4-Chloroaniline<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.90%<\/td>\n<\/tr>\n<tr>\n<td>Hexachlorobutadiene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.70%<\/td>\n<\/tr>\n<tr>\n<td>4-Chloro-3-methylphenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.40%<\/td>\n<\/tr>\n<tr>\n<td>2-Methylnaphthalene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.40%<\/td>\n<\/tr>\n<tr>\n<td>1-Methylnaphthalene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.60%<\/td>\n<\/tr>\n<tr>\n<td>Hexachlorocyclopentadiene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">6.90%<\/td>\n<\/tr>\n<tr>\n<td>2,4,6-Trichlorophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">5.90%<\/td>\n<\/tr>\n<tr>\n<td>2,4,5-Trichlorophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">6.20%<\/td>\n<\/tr>\n<tr>\n<td>(SS) 2-Fluorobiphenyl<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">1.10%<\/td>\n<\/tr>\n<tr>\n<td>2-Chloronaphthalene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">2.80%<\/td>\n<\/tr>\n<tr>\n<td>2-Nitroaniline<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">7.80%<\/td>\n<\/tr>\n<tr>\n<td>1,4-Dinitrobenzene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">11.10%<\/td>\n<\/tr>\n<tr>\n<td>Dimethyl phthalate<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.40%<\/td>\n<\/tr>\n<tr>\n<td>1,3-Dinitrobenzene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">10.80%<\/td>\n<\/tr>\n<tr>\n<td>2,6-Dinitrotoluene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">7.80%<\/td>\n<\/tr>\n<tr>\n<td>Acenaphthylene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.10%<\/td>\n<\/tr>\n<tr>\n<td>1,2-Dinitrobenzene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">8.10%<\/td>\n<\/tr>\n<tr>\n<td>3-Nitroaniline<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">5.80%<\/td>\n<\/tr>\n<tr>\n<td>Acenaphthene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.30%<\/td>\n<\/tr>\n<tr>\n<td>2,4-Dinitrophenol<\/td>\n<td style=\"text-align: center;\">2.5 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">17.30%<\/td>\n<\/tr>\n<tr>\n<td>4-Nitrophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">7.90%<\/td>\n<\/tr>\n<tr>\n<td>Dibenzofuran<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.50%<\/td>\n<\/tr>\n<tr>\n<td>2,4-Dinitrotoluene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">11.60%<\/td>\n<\/tr>\n<tr>\n<td>2,3,5,6-Tetrachlorophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">10.40%<\/td>\n<\/tr>\n<tr>\n<td>2,3,4,6-Tetrachlorophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">7.30%<\/td>\n<\/tr>\n<tr>\n<td>Diethyl phthalate<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.50%<\/td>\n<\/tr>\n<tr>\n<td>4-Chlorophenyl phenyl ether<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.60%<\/td>\n<\/tr>\n<tr>\n<td>Fluorene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.40%<\/td>\n<\/tr>\n<tr>\n<td>4-Nitroaniline<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">9.10%<\/td>\n<\/tr>\n<tr>\n<td>4,6-Dinitro-2-methylphenol<\/td>\n<td style=\"text-align: center;\">2.5 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">15.10%<\/td>\n<\/tr>\n<tr>\n<td>N-nitrosodiphenylamine<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.60%<\/td>\n<\/tr>\n<tr>\n<td>Diphenylhydrazine<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.60%<\/td>\n<\/tr>\n<tr>\n<td>(SS) 2,4,6-Tribromophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">5.50%<\/td>\n<\/tr>\n<tr>\n<td>4-Bromophenyl phenyl ether<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">5.50%<\/td>\n<\/tr>\n<tr>\n<td>Hexachlorobenzene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.30%<\/td>\n<\/tr>\n<tr>\n<td>Pentachlorophenol<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">10.60%<\/td>\n<\/tr>\n<tr>\n<td>Phenanthrene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.70%<\/td>\n<\/tr>\n<tr>\n<td>Anthracene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.80%<\/td>\n<\/tr>\n<tr>\n<td>Carbazole<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">5.30%<\/td>\n<\/tr>\n<tr>\n<td>di-<em>n<\/em>-Butyl phthalate<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">7.90%<\/td>\n<\/tr>\n<tr>\n<td>Fluoranthene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">5.10%<\/td>\n<\/tr>\n<tr>\n<td>Benzidine<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">9.30%<\/td>\n<\/tr>\n<tr>\n<td>(SS) Pyrene-D10<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">1.50%<\/td>\n<\/tr>\n<tr>\n<td>Pyrene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.30%<\/td>\n<\/tr>\n<tr>\n<td>(SS)\u00a0<em>p<\/em>-Terphenyl-d14<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">1.80%<\/td>\n<\/tr>\n<tr>\n<td>3,3&#8242;-Dimethylbenzidine<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">9.50%<\/td>\n<\/tr>\n<tr>\n<td>Butyl benzyl phthalate<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">8.60%<\/td>\n<\/tr>\n<tr>\n<td>Bis(2-ethylhexyl)adipate<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">10.50%<\/td>\n<\/tr>\n<tr>\n<td>3,3&#8242;-Dichlorobenzidine<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">8.50%<\/td>\n<\/tr>\n<tr>\n<td>Benz[a]anthracene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.20%<\/td>\n<\/tr>\n<tr>\n<td>Chrysene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">3.70%<\/td>\n<\/tr>\n<tr>\n<td>Bis(2-ethylhexyl)phthalate<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">10.40%<\/td>\n<\/tr>\n<tr>\n<td>Di-<em>n<\/em>-octyl phthalate<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">13.20%<\/td>\n<\/tr>\n<tr>\n<td>Benzo[b]fluoranthene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">5.60%<\/td>\n<\/tr>\n<tr>\n<td>Benzo[k]fluoranthene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">4.90%<\/td>\n<\/tr>\n<tr>\n<td>Benzo[a]pyrene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">6.30%<\/td>\n<\/tr>\n<tr>\n<td>Indeno[123-cd]pyrene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">7.20%<\/td>\n<\/tr>\n<tr>\n<td>Dibenz[a,h]anthracene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">7.50%<\/td>\n<\/tr>\n<tr>\n<td>Benzo[ghi]perylene<\/td>\n<td style=\"text-align: center;\">1 &#8211; 120<\/td>\n<td style=\"background-color: #daecd4; text-align: center;\">6.40%<\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td style=\"text-align: center;\"><strong>Average %RSD:<\/strong><\/td>\n<td style=\"background-color: #daecd4; text-align: center;\"><strong>6.00%<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2 :<\/strong>\u00a0Tr\u00e8s inertes, les colonnes Rxi-SVOCms produisent des pics d\u2019une grande finesse et des temps de r\u00e9tention r\u00e9guliers, m\u00eame pour les faibles quantit\u00e9s de compos\u00e9s r\u00e9actifs qui ont tendance \u00e0 \u00e9chouer, comme la pyridine (amine basique) et le pentachloroph\u00e9nol (ph\u00e9nol acide).<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1605.png\" alt=\"Balanced Rxi-SVOCms Column Chemistry Produces Symmetrical Peaks and Stable Retention Times as Mass on Column Varies\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1605<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-4 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyridine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110-86-1\/Pyridine\" target=\"_blank\" rel=\"noopener\">Pyridine<\/a><\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/87-86-5\/Pentachlorophenol\" target=\"_blank\" rel=\"noopener\">Pentachlorophenol<\/a><\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>16623<\/li><li>23303<\/li><li>21143<\/li><li>21782<\/li><li>23842<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>SVOC<\/li><li>semivolatile<\/li><li>semivolatiles<\/li><li>semivolatiles-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1605.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<h2 class=\"wp-block-heading\">Des performances restaur\u00e9es facilement avec les colonnes robustes et longue dur\u00e9e Rxi-SVOCms<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019accumulation de compos\u00e9s provenant d\u2019\u00e9chantillons environnementaux tr\u00e8s complexes est un d\u00e9fi du quotidien, mais cela ne d\u00e9t\u00e9riore pas n\u00e9cessairement les colonnes. La phase am\u00e9lior\u00e9e garantit la durabilit\u00e9 des performances des colonnes Rxi-SVOCms, m\u00eame en conditions tr\u00e8s agressives. La Figure 3 montre les performances d\u2019\u00e9talonnage pour des colonnes soumises \u00e0 des injections r\u00e9p\u00e9t\u00e9es d\u2019un \u00e9chantillon complexe et dont les parties contamin\u00e9es \u00e9taient coup\u00e9es apr\u00e8s 30 injections. M\u00eame apr\u00e8s 300 injections, les performances \u00e9taient restaur\u00e9es facilement au moyen d\u2019un rapide raccourcissement de colonne, comme en t\u00e9moignent les moins de 10 % de compos\u00e9s concern\u00e9s par un \u00e9chec de la v\u00e9rification de l&#8217;\u00e9talonnage apr\u00e8s la coupe. En restaurant les performances gr\u00e2ce \u00e0 une simple op\u00e9ration de maintenance de routine, le nombre d&#8217;\u00e9chantillons analys\u00e9s augmente car les temps d\u2019arr\u00eat et les remplacements de colonnes sont moins fr\u00e9quents.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3 :<\/strong>\u00a0Apr\u00e8s une exposition r\u00e9p\u00e9t\u00e9e \u00e0 un \u00e9chantillon tr\u00e8s complexe, les performances des colonnes sont enti\u00e8rement restaur\u00e9es par un raccourcissement en t\u00eate de colonne. Les robustes colonnes Rxi-SVOCms retrouvent alors leurs performances initiales pour vous permettre de continuer les analyses au lieu de changer de colonne et de r\u00e9\u00e9talonner.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<p class=\"wp-block-paragraph\"><em>Caract\u00e9ristiques exp\u00e9rimentales du test de robustesse avec 300 \u00e9chantillons<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Chaque jour, 30 injections d\u2019extrait de particules de gasoil (NIST SRM 1975) ont \u00e9t\u00e9 r\u00e9alis\u00e9es, et un contr\u00f4le CCV (Continuing Calibration Validation) a \u00e9t\u00e9 utilis\u00e9 toutes les 10 injections d&#8217;\u00e9chantillon. Apr\u00e8s la troisi\u00e8me analyse CCV quotidienne, l\u2019extr\u00e9mit\u00e9 de la colonne a \u00e9t\u00e9 coup\u00e9e et l\u2019insert, le septum et le plancher d&#8217;injecteur ont \u00e9t\u00e9 remplac\u00e9s. Cette s\u00e9quence a \u00e9t\u00e9 r\u00e9it\u00e9r\u00e9e pendant 10 jours et l\u2019exp\u00e9rience a \u00e9t\u00e9 r\u00e9p\u00e9t\u00e9e sur une deuxi\u00e8me colonne<\/em><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong><em>La courbe bleue<\/em><\/strong><em>&nbsp;repr\u00e9sente toutes les injections de CCV et montre que les performances ont commenc\u00e9 par baisser, comme pr\u00e9vu, en raison de la contamination par la matrice de l\u2019\u00e9chantillon, puis ont \u00e9t\u00e9 restaur\u00e9es apr\u00e8s la maintenance.<\/em><\/li>\n\n\n\n<li><strong><em>La courbe verte<\/em><\/strong><em>&nbsp;repr\u00e9sente seulement les injections de CCV cons\u00e9cutives \u00e0 la maintenance et indique une stabilit\u00e9 des performances de l\u2019\u00e9talonnage<\/em><\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"742\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVSS3820-03-1024x742.jpg\" alt=\"\" class=\"wp-image-18058\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVSS3820-03-1024x742.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVSS3820-03-300x217.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVSS3820-03-768x556.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVSS3820-03-1536x1113.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-EVSS3820-03.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div><\/div><\/div>\n\n\n<h2 class=\"wp-block-heading\">Des performances constantes et pr\u00e9cises int\u00e9gr\u00e9es dans chaque colonne<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Du polym\u00e8re exclusif au contr\u00f4le qualit\u00e9 du produit final, chaque aspect de la fabrication des colonnes Rxi-SVOCms est \u00e9troitement contr\u00f4l\u00e9 et fait l\u2019objet d\u2019essais r\u00e9p\u00e9titifs exigeants. Il en r\u00e9sulte des performances extr\u00eamement constantes d\u2019une colonne \u00e0 l\u2019autre, pour obtenir des analyses chromatographiques identiques de chaque colonne install\u00e9e. Les colonnes Rxi-SVOCms se caract\u00e9risent par des temps de r\u00e9tention stables, m\u00eame pour le 2,4-dinitroph\u00e9nol, un compos\u00e9 actif souvent probl\u00e9matique, et par des profils de &#8220;bleeding&#8221; extr\u00eamement faible (Figure 4).<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4 :<\/strong>\u00a0Chaque colonne Rxi-SVOCms fournit des temps de r\u00e9tention r\u00e9guliers et un faible &#8220;bleeding&#8221; pour des r\u00e9sultats chromatographiques fiables avec chaque colonne.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1215.png\" alt=\"Rxi-SVOCms Column-to-Column Reproducibility\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1215<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Picoline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-89-4\/4-Picoline\" target=\"_blank\" rel=\"noopener\">4-Picoline<\/a><\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Ethylhexanoic acid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/149-57-5\/2-Ethylhexanoic acid\" target=\"_blank\" rel=\"noopener\">2-Ethylhexanoic acid<\/a><\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,6-Hexanediol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/629-11-8\/1,6-Hexanediol\" target=\"_blank\" rel=\"noopener\">1,6-Hexanediol<\/a><\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Chlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-48-9\/4-Chlorophenol\" target=\"_blank\" rel=\"noopener\">4-Chlorophenol<\/a><\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for n-Tridecane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/629-50-5\/n-Tridecane\" target=\"_blank\" rel=\"noopener\">n-Tridecane<\/a><\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Methylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90-12-0\/1-Methylnaphthalene\" target=\"_blank\" rel=\"noopener\">1-Methylnaphthalene<\/a><\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Undecanol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/112-42-5\/1-Undecanol\" target=\"_blank\" rel=\"noopener\">1-Undecanol<\/a><\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for n-Tetradecane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/629-59-4\/n-Tetradecane\" target=\"_blank\" rel=\"noopener\">n-Tetradecane<\/a><\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dicyclohexylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/101-83-7\/Dicyclohexylamine\" target=\"_blank\" rel=\"noopener\">Dicyclohexylamine<\/a><\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthene-d10\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/15067-26-2\/Acenaphthene-d10\" target=\"_blank\" rel=\"noopener\">Acenaphthene-d10<\/a><\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dinitrophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51-28-5\/2,4-Dinitrophenol\" target=\"_blank\" rel=\"noopener\">2,4-Dinitrophenol<\/a><\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/87-86-5\/Pentachlorophenol\" target=\"_blank\" rel=\"noopener\">Pentachlorophenol<\/a><\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92-87-5\/Benzidine\" target=\"_blank\" rel=\"noopener\">Benzidine<\/a><\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">200:1 split results in approximately 1 ng on column.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rxi-SVOCms, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/16623\" rel=\"noopener\">cat.# 16623<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Low-level activity test mix<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Dichloromethane<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>200 \u00b5g\/mL<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 200:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 4.0 mm ID Precision inlet liner with wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23305\" rel=\"noopener\">cat.# 23305<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Split Vent Flow Rate:<\/th><td>236 mL\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>125 &#176;C (hold 12.5 min) to 340 &#176;C at 20 &#176;C\/min (hold 4 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Linear Velocity:<\/th><td>32 cm\/sec @ 125 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dead Time:<\/th><td>1.5885  min @ 125 \u00b0C<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>FID @ 350 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Make-up Gas Flow Rate:<\/th><td>40 mL\/min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Make-up Gas Type:<\/th><td>N<sub>2<\/sub> <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Hydrogen flow:<\/th><td>40 mL\/min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Air flow:<\/th><td>400 mL\/min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Data Rate:<\/th><td>50 Hz<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890B GC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Samples were aliquoted into amber 2 mL, 9 mm short-cap, screw-thread vials (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21143\" rel=\"noopener\">cat.# 21143<\/a>) containing glass Big Mouth inserts (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21782\" rel=\"noopener\">cat.# 21782<\/a>) and sealed with 2.0 mL, 9 mm short-cap, screw-vial closures (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23842\" rel=\"noopener\">cat.# 23842<\/a>).<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>16623<\/li><li>23305<\/li><li>21143<\/li><li>21782<\/li><li>23842<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>SVOC<\/li><li>semivolatile<\/li><li>semivolatiles<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1215.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<h2 class=\"wp-block-heading\">R\u00e9solution fiable des HAP dans l\u2019environnement<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Les hydrocarbures aromatiques polycycliques (HAP) font partie des compos\u00e9s les plus difficiles \u00e0 s\u00e9parer avec les m\u00e9thodes de d\u00e9tection des compos\u00e9s semi-volatils. L\u2019obtention de r\u00e9sultats pr\u00e9cis pour les analyses de traces n\u00e9cessite une colonne tr\u00e8s s\u00e9lective et efficace, capable de s\u00e9parer des compos\u00e9s avec des temps de r\u00e9tention proches. La Figure 5 montre que la colonne Rxi-SVOCms offre une r\u00e9solution optimis\u00e9e pour 23 polluants prioritaires, notamment le benzo(b)fluoranth\u00e8ne et le benzo(k)fluoranth\u00e8ne, qui doivent \u00eatre s\u00e9par\u00e9s par la chromatographie pour pouvoir les quantifier individuellement.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5 :<\/strong>\u00a0Les colonnes Rxi-SVOCms fournissent une s\u00e9paration optimis\u00e9e pour des HAP dont les temps de r\u00e9tention sont tr\u00e8s proches, notamment des isobares qui ne peuvent pas \u00eatre identifi\u00e9s seulement par la MS.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1609.png\" alt=\"Priority PAH Pollutants on Rxi-SVOCms (SIM)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1609<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Naphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-20-3\/Naphthalene\" target=\"_blank\" rel=\"noopener\">Naphthalene<\/a><\/td><td class=\"oth\">6.27<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Methylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-57-6\/2-Methylnaphthalene\" target=\"_blank\" rel=\"noopener\">2-Methylnaphthalene<\/a><\/td><td class=\"oth\">7.09<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Methylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90-12-0\/1-Methylnaphthalene\" target=\"_blank\" rel=\"noopener\">1-Methylnaphthalene<\/a><\/td><td class=\"oth\">7.20<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Biphenyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92-52-4\/Biphenyl\" target=\"_blank\" rel=\"noopener\">Biphenyl<\/a><\/td><td class=\"oth\">7.65<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,6-Dimethylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/581-42-0\/2,6-Dimethylnaphthalene\" target=\"_blank\" rel=\"noopener\">2,6-Dimethylnaphthalene<\/a><\/td><td class=\"oth\">7.84<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/208-96-8\/Acenaphthylene\" target=\"_blank\" rel=\"noopener\">Acenaphthylene<\/a><\/td><td class=\"oth\">8.17<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/83-32-9\/Acenaphthene\" target=\"_blank\" rel=\"noopener\">Acenaphthene<\/a><\/td><td class=\"oth\">8.38<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,3,5-Trimethylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2245-38-7\/2,3,5-Trimethylnaphthalene\" target=\"_blank\" rel=\"noopener\">2,3,5-Trimethylnaphthalene<\/a><\/td><td class=\"oth\">8.85<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluorene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/86-73-7\/Fluorene\" target=\"_blank\" rel=\"noopener\">Fluorene<\/a><\/td><td class=\"oth\">9.01<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenzothiophene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/132-65-0\/Dibenzothiophene\" target=\"_blank\" rel=\"noopener\">Dibenzothiophene<\/a><\/td><td class=\"oth\">10.02<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenanthrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85-01-8\/Phenanthrene\" target=\"_blank\" rel=\"noopener\">Phenanthrene<\/a><\/td><td class=\"oth\">10.18<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-12-7\/Anthracene\" target=\"_blank\" rel=\"noopener\">Anthracene<\/a><\/td><td class=\"oth\">10.24<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Methylphenanthrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/832-69-9\/1-Methylphenanthrene\" target=\"_blank\" rel=\"noopener\">1-Methylphenanthrene<\/a><\/td><td class=\"oth\">10.94<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/206-44-0\/Fluoranthene\" target=\"_blank\" rel=\"noopener\">Fluoranthene<\/a><\/td><td class=\"oth\">11.64<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/129-00-0\/Pyrene\" target=\"_blank\" rel=\"noopener\">Pyrene<\/a><\/td><td class=\"oth\">11.91<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benz[a]anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-55-3\/Benz[a]anthracene\" target=\"_blank\" rel=\"noopener\">Benz[a]anthracene<\/a><\/td><td class=\"oth\">13.45<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chrysene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/218-01-9\/Chrysene\" target=\"_blank\" rel=\"noopener\">Chrysene<\/a><\/td><td class=\"oth\">13.50<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[b]fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/205-99-2\/Benzo[b]fluoranthene\" target=\"_blank\" rel=\"noopener\">Benzo[b]fluoranthene<\/a><\/td><td class=\"oth\">15.13<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[k]fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/207-08-9\/Benzo[k]fluoranthene\" target=\"_blank\" rel=\"noopener\">Benzo[k]fluoranthene<\/a><\/td><td class=\"oth\">15.18<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[a]pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-32-8\/Benzo[a]pyrene\" target=\"_blank\" rel=\"noopener\">Benzo[a]pyrene<\/a><\/td><td class=\"oth\">15.69<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Indeno[1,2,3-cd]pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/193-39-5\/Indeno[1,2,3-cd]pyrene\" target=\"_blank\" rel=\"noopener\">Indeno[1,2,3-cd]pyrene<\/a><\/td><td class=\"oth\">17.77<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenz[a,h]anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53-70-3\/Dibenz[a,h]anthracene\" target=\"_blank\" rel=\"noopener\">Dibenz[a,h]anthracene<\/a><\/td><td class=\"oth\">17.82<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[ghi]perylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/191-24-2\/Benzo[ghi]perylene\" target=\"_blank\" rel=\"noopener\">Benzo[ghi]perylene<\/a><\/td><td class=\"oth\">18.26<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">The internal standard and surrogate standard mass on column is 20 pg.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rxi-SVOCms, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/16623\" rel=\"noopener\">cat.# 16623<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Custom PAH SIM standard<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Dichloromethane<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>40 \u00b5g\/mL<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 20:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 4.0 mm ID single taper inlet liner with wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23303\" rel=\"noopener\">cat.# 23303<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Split Vent Flow Rate:<\/th><td>24 mL\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>40 &#176;C (hold 0.5 min) to 280 &#176;C at 20 &#176;C\/min to 330 &#176;C at 6 &#176;C\/min (hold 4 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.2 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>SIM<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">SIM Program:<\/th><td><\/td><\/tr><tr><td style=\"text-align:left\" colspan=\"2\"><table class=\"conditions_sim\"><thead><tr><th style=\"padding: 0 5px\">Group<\/th><th style=\"padding: 0 5px\">Start Time<br \/>(min)<\/th><th style=\"padding: 0 5px\">Ion(s) (m\/z)<\/th><th style=\"padding: 0 5px\">Dwell (ms)<\/th><\/tr><\/thead><tbody><tr><td style=\"vertical-align:top\">1<\/td><td style=\"vertical-align:top\">5.00<\/td><td>127.05, 128.05, 129.00 <\/td><td>25<\/td><\/tr><tr><td style=\"vertical-align:top\">2<\/td><td style=\"vertical-align:top\">6.75<\/td><td>115.10, 139.00, 141.00, 142.05 <\/td><td>25<\/td><\/tr><tr><td style=\"vertical-align:top\">3<\/td><td style=\"vertical-align:top\">7.47<\/td><td>141.00, 152.00, 153.05, 154.05, 155.05, 156.10, 162.10, 164.10 <\/td><td>15<\/td><\/tr><tr><td style=\"vertical-align:top\">4<\/td><td style=\"vertical-align:top\">8.03<\/td><td>150.00, 151.05, 152.05, 153.05, 154.10, 162.10, 164.10 <\/td><td>15<\/td><\/tr><tr><td style=\"vertical-align:top\">5<\/td><td style=\"vertical-align:top\">8.66<\/td><td>153.05, 155.10, 163.05, 164.10, 165.05, 166.05, 169.10, 170.10 <\/td><td>15<\/td><\/tr><tr><td style=\"vertical-align:top\">6<\/td><td style=\"vertical-align:top\">9.62<\/td><td>139.00, 151.95, 176.10, 177.10, 178.10, 179.10, 183.95, 185.00, 188.10, 189.10 <\/td><td>15<\/td><\/tr><tr><td style=\"vertical-align:top\">7<\/td><td style=\"vertical-align:top\">10.71<\/td><td>189.05, 190.05, 191.10, 192.10 <\/td><td>25<\/td><\/tr><tr><td style=\"vertical-align:top\">8<\/td><td style=\"vertical-align:top\">11.37<\/td><td>200.10, 201.10, 202.10, 203.05 <\/td><td>20<\/td><\/tr><tr><td style=\"vertical-align:top\">9<\/td><td style=\"vertical-align:top\">11.81<\/td><td>200.10, 201.05, 202.05, 203.05 <\/td><td>20<\/td><\/tr><tr><td style=\"vertical-align:top\">10<\/td><td style=\"vertical-align:top\">12.84<\/td><td>114.00, 120.00, 226.10, 227.10, 228.10, 229.10, 240.10 <\/td><td>15<\/td><\/tr><tr><td style=\"vertical-align:top\">11<\/td><td style=\"vertical-align:top\">14.48<\/td><td>126.00, 132.00, 250.10, 252.10, 253.10, 264.00 <\/td><td>15<\/td><\/tr><tr><td style=\"vertical-align:top\">12<\/td><td style=\"vertical-align:top\">15.51<\/td><td>126.00, 132.00, 250.05, 252.05, 253.05, 264.00 <\/td><td>20<\/td><\/tr><tr><td style=\"vertical-align:top\">13<\/td><td style=\"vertical-align:top\">16.95<\/td><td>134.50, 137.95, 139.00, 274.05, 276.10, 277.10, 278.10, 279.10 <\/td><td>20<\/td><\/tr><tr><td style=\"vertical-align:top\">14<\/td><td style=\"vertical-align:top\">18.10<\/td><td>138.00, 139.00, 274.05, 276.10, 277.10, 278.1 <\/td><td>25<\/td><\/tr><tr><td style=\"vertical-align:top\">15<\/td><td style=\"vertical-align:top\">18.80<\/td><td>150.00, 151.00, 156.00, 600.00, 302.00, 312.00 <\/td><td>25<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Type:<\/th><td>Extractor <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Extractor Lens:<\/th><td>6 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>330 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Quad Temp.:<\/th><td>150 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>DFTPP <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890B GC &amp; 5977A MSD<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>200 ppm standard diluted 5x, then analyzed at 20:1 split. Samples were aliquoted into amber 2 mL, 9 mm short-cap, screw-thread vials (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21143\" rel=\"noopener\">cat.# 21143<\/a>) containing glass Big Mouth inserts (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21782\" rel=\"noopener\">cat.# 21782<\/a>) and sealed with 2.0 mL, 9 mm short-cap, screw-vial closures (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23842\" rel=\"noopener\">cat.# 23842<\/a>).<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>16623<\/li><li>23303<\/li><li>21143<\/li><li>21782<\/li><li>23842<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>PAH<\/li><li>aromatic<\/li><li>hydrocarbons<\/li><li>polycyclic<\/li><li>semivolatiles-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1609.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Related Products<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31907\">                                R\u00e9f. 31907                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Kit de solutions-\u00e9talons SVOC MegaMix 150, 1 ml\/ampoule ; 6 ampoules\/kit<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31907\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31908\">                                R\u00e9f. 31908                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Kit de solutions-\u00e9talons SVOC MegaMix 100, 1 ml\/ampoule ; 3 ampoules\/kit<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31908\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Sp\u00e9cialement con\u00e7ues pour les analyses de compos\u00e9s semi-volatils, les nouvelles colonnes Restek Rxi-SVOCms garantissent des performances constantes qui pr\u00e9servent l\u2019\u00e9talonnage de la colonne afin de prolonger les temps d\u2019analyse au maximum avant de devoir r\u00e9\u00e9talonner l\u2019instrument ou remplacer la colonne.<\/p>\n","protected":false},"author":11,"featured_media":25644,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[462],"tags":[],"industries-application":[2210,2208,2668],"post-badge":[],"resource-type":[],"product-library":[2456,2444],"resource-technique":[2316,2320],"ppma_author":[414],"class_list":["post-43528","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-fr","industries-application-eau-potable-eaux-usees","industries-application-environnement","industries-application-semivolatiles","product-library-colonnes-gc","product-library-produits-pour-la-chromatographie-en-phase-gazeuse","resource-technique-chromatographie-en-phase-gazeuse-gc","resource-technique-spectrometrie-de-masse-ms"],"acf":[],"taxonomy_info":{"category":[{"value":462,"label":"Articles"}],"industries-application":[{"value":2210,"label":"Eau potable et eaux us\u00e9es"},{"value":2208,"label":"Environnement"},{"value":2668,"label":"Semivolatiles"}],"product-library":[{"value":2456,"label":"Colonnes GC"},{"value":2444,"label":"Produits pour la chromatographie en phase gazeuse"}],"resource-technique":[{"value":2316,"label":"Chromatographie en phase gazeuse (GC)"},{"value":2320,"label":"Spectrom\u00e9trie de masse (MS)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/header-article-EVSS3820-1024x466.jpg",1024,466,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":462,"name":"Articles","slug":"articles-fr","term_group":0,"term_taxonomy_id":462,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":462,"category_count":511,"category_description":"","cat_name":"Articles","category_nicename":"articles-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43528","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=43528"}],"version-history":[{"count":9,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43528\/revisions"}],"predecessor-version":[{"id":85149,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43528\/revisions\/85149"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/25644"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=43528"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=43528"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=43528"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=43528"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=43528"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=43528"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=43528"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=43528"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=43528"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}