{"id":43541,"date":"2020-10-21T00:00:00","date_gmt":"2020-10-21T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/highly-reproducible-detailed-cistrans-fames-analysis-ensured-by-new-optimized-rt-2560-column-manufacturing-and-application-specific-qc-test\/"},"modified":"2026-08-11T15:19:26","modified_gmt":"2026-08-11T15:19:26","slug":"highly-reproducible-detailed-cistrans-fames-analysis-ensured-by-new-optimized-rt-2560-column-manufacturing-and-application-specific-qc-test","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/articles\/ffar2589\/highly-reproducible-detailed-cistrans-fames-analysis-ensured-by-new-optimized-rt-2560-column-manufacturing-and-application-specific-qc-test","title":{"rendered":"Highly Reproducible Detailed <em>cis\/trans<\/em> FAMEs Analysis Ensured by New Optimized Rt-2560 Column Manufacturing and Application-Specific QC Test"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Restek\u2019s Rt-2560 GC column is commonly used for detailed analysis of fatty acid methyl esters (FAMEs) in foods; for the determination of&nbsp;<em>trans<\/em>&nbsp;fat content in foods and edible oils; and for profiling of fatty acids in edible oils. The column is well suited to this purpose as it contains a highly polar, nonbonded, biscyanopropyl polysiloxane stationary phase housed in a 100 m x 0.25 mm x 0.20 \u00b5m column format. The length and polarity of the column allow it to separate FAMES based on chain length and degree of unsaturation, as well as the positional and geometrical isomerism of double bonds. However, as a consequence of the column\u2019s length and high polarity, even minor variations in the manufacturing process can potentially have detrimental effects on column-to-column reproducibility. Restek has optimized the manufacturing process and implemented a new, application-specific, QC-testing procedure for all new Rt-2560 columns (cat.# 13198) in order to ensure consistent performance for detailed&nbsp;<em>cis\/trans<\/em>&nbsp;FAMEs analysis.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Redesigned Process Produces Consistent Column Performance<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The optimized manufacturing process for Rt-2560 columns results in highly consistent performance from one column to the next without affecting important features of the original column, such as selectivity, sample loading capacity, stationary phase bleed, and thermal stability. Figure 1 demonstrates the excellent column-to-column reproducibility that is typically observed across different lots of Rt-2560 polymer. In addition, low bleed levels are consistently obtained, even at the upper temperature limit of 250 \u00b0C.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong>\u00a0Rt-2560 columns manufactured under Restek\u2019s optimized procedure exhibit highly reproducible column-to-column performance for detailed\u00a0<em>cis\/trans<\/em>\u00a0FAMEs analysis.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1263.png\" alt=\"Lot-to-Lot Reproducibility of the Rt-2560 Stationary Phase Polymer\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FF1263<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-4 col-12 peak-33\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(mg\/mL)<\/th><th style=\"text-align: center;width: 75px\">Structural Nomenclature<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl butyrate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/623-42-7\/Methyl butyrate\" target=\"_blank\" rel=\"noopener\">Methyl butyrate<\/a><\/td><td class=\"oth\">11.92<\/td><td class=\"oth\">40<\/td><td class=\"oth\">C4:0<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl caproate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-70-7\/Methyl caproate\" target=\"_blank\" rel=\"noopener\">Methyl caproate<\/a><\/td><td class=\"oth\">14.13<\/td><td class=\"oth\">40<\/td><td class=\"oth\">C6:0<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl octanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111-11-5\/Methyl octanoate\" target=\"_blank\" rel=\"noopener\">Methyl octanoate<\/a><\/td><td class=\"oth\">17.85<\/td><td class=\"oth\">40<\/td><td class=\"oth\">C8:0<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl decanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110-42-9\/Methyl decanoate\" target=\"_blank\" rel=\"noopener\">Methyl decanoate<\/a><\/td><td class=\"oth\">22.80<\/td><td class=\"oth\">40<\/td><td class=\"oth\">C10:0<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl undecanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1731-86-8\/Methyl undecanoate\" target=\"_blank\" rel=\"noopener\">Methyl undecanoate<\/a><\/td><td class=\"oth\">25.46<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C11:0<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl dodecanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111-82-0\/Methyl dodecanoate\" target=\"_blank\" rel=\"noopener\">Methyl dodecanoate<\/a><\/td><td class=\"oth\">28.12<\/td><td class=\"oth\">40<\/td><td class=\"oth\">C12:0<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl tridecanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1731-88-0\/Methyl tridecanoate\" target=\"_blank\" rel=\"noopener\">Methyl tridecanoate<\/a><\/td><td class=\"oth\">30.71<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C13:0<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl myristate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/124-10-7\/Methyl myristate\" target=\"_blank\" rel=\"noopener\">Methyl myristate<\/a><\/td><td class=\"oth\">33.21<\/td><td class=\"oth\">40<\/td><td class=\"oth\">C14:0<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl myristoleate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56219-06-8\/Methyl myristoleate\" target=\"_blank\" rel=\"noopener\">Methyl myristoleate<\/a><\/td><td class=\"oth\">35.22<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C14:1 (c9)<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl pentadecanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7132-64-1\/Methyl pentadecanoate\" target=\"_blank\" rel=\"noopener\">Methyl pentadecanoate<\/a><\/td><td class=\"oth\">35.60<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C15:0<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl pentadecenoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90176-52-6\/Methyl pentadecenoate\" target=\"_blank\" rel=\"noopener\">Methyl pentadecenoate<\/a><\/td><td class=\"oth\">37.57<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C15:1 (c10)<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl palmitate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/112-39-0\/Methyl palmitate\" target=\"_blank\" rel=\"noopener\">Methyl palmitate<\/a><\/td><td class=\"oth\">37.90<\/td><td class=\"oth\">60<\/td><td class=\"oth\">C16:0<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-4 col-12 peak-33\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(mg\/mL)<\/th><th style=\"text-align: center;width: 75px\">Structural Nomenclature<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl palmitoleate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1120-25-8\/Methyl palmitoleate\" target=\"_blank\" rel=\"noopener\">Methyl palmitoleate<\/a><\/td><td class=\"oth\">39.51<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C16:1 (c9)<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl heptadecanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1731-92-6\/Methyl heptadecanoate\" target=\"_blank\" rel=\"noopener\">Methyl heptadecanoate<\/a><\/td><td class=\"oth\">40.09<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C17:0<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl heptadecenoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/75190-82-8\/Methyl heptadecenoate\" target=\"_blank\" rel=\"noopener\">Methyl heptadecenoate<\/a><\/td><td class=\"oth\">41.66<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C17:1 (c10)<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl stearate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/112-61-8\/Methyl stearate\" target=\"_blank\" rel=\"noopener\">Methyl stearate<\/a><\/td><td class=\"oth\">42.19<\/td><td class=\"oth\">40<\/td><td class=\"oth\">C18:0<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl octadecenoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1937-62-8\/Methyl octadecenoate\" target=\"_blank\" rel=\"noopener\">Methyl octadecenoate<\/a><\/td><td class=\"oth\">43.13<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C18:1 (t9)<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl oleate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/112-62-9\/Methyl oleate\" target=\"_blank\" rel=\"noopener\">Methyl oleate<\/a><\/td><td class=\"oth\">43.54<\/td><td class=\"oth\">40<\/td><td class=\"oth\">C18:1 (c9)<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl linoleaidate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2566-97-4\/Methyl linoleaidate\" target=\"_blank\" rel=\"noopener\">Methyl linoleaidate<\/a><\/td><td class=\"oth\">44.60<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C18:2 (t9,t12)<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl linoleate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/112-63-0\/Methyl linoleate\" target=\"_blank\" rel=\"noopener\">Methyl linoleate<\/a><\/td><td class=\"oth\">45.50<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C18:2 (c9,c12)<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl arachidate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1120-28-1\/Methyl arachidate\" target=\"_blank\" rel=\"noopener\">Methyl arachidate<\/a><\/td><td class=\"oth\">46.12<\/td><td class=\"oth\">40<\/td><td class=\"oth\">C20:0<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl linolenate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/301-00-8\/Methyl linolenate\" target=\"_blank\" rel=\"noopener\">Methyl linolenate<\/a><\/td><td class=\"oth\">46.94<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C18:3 (c6,c9,c12)<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl eicosenoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2390-09-2\/Methyl eicosenoate\" target=\"_blank\" rel=\"noopener\">Methyl eicosenoate<\/a><\/td><td class=\"oth\">47.39<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C20:1 (c11)<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl linolenate \" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/301-00-8\/Methyl linolenate \" target=\"_blank\" rel=\"noopener\">Methyl linolenate <\/a><\/td><td class=\"oth\">47.71<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C18:3 (c9,c12,c15)<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-4 col-12 peak-33\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(mg\/mL)<\/th><th style=\"text-align: center;width: 75px\">Structural Nomenclature<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl heneicosanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/6064-90-0\/Methyl heneicosanoate\" target=\"_blank\" rel=\"noopener\">Methyl heneicosanoate<\/a><\/td><td class=\"oth\">47.97<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C21:0<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl eicosadienoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2463-02-7\/Methyl eicosadienoate\" target=\"_blank\" rel=\"noopener\">Methyl eicosadienoate<\/a><\/td><td class=\"oth\">49.26<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C20:2 (c11,c14)<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl behenate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/929-77-1\/Methyl behenate\" target=\"_blank\" rel=\"noopener\">Methyl behenate<\/a><\/td><td class=\"oth\">49.77<\/td><td class=\"oth\">40<\/td><td class=\"oth\">C22:0<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\">Methyl eicosatrienoate <\/td><td class=\"oth\">50.62<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C20:3 (c8,c11,c14)<\/td><\/tr>\n<tr><td class=\"num\">29.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl erucate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1120-34-9\/Methyl erucate\" target=\"_blank\" rel=\"noopener\">Methyl erucate<\/a><\/td><td class=\"oth\">50.98<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C22:1 (c13)<\/td><\/tr>\n<tr><td class=\"num\">30.<\/td><td class=\"cmpd\">Methyl eicosatrienoate <\/td><td class=\"oth\">51.34<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C20:3 (c11,c14,c17)<\/td><\/tr>\n<tr><td class=\"num\">31.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl tricosanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2433-97-8\/Methyl tricosanoate\" target=\"_blank\" rel=\"noopener\">Methyl tricosanoate<\/a><\/td><td class=\"oth\">51.48<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C23:0<\/td><\/tr>\n<tr><td class=\"num\">32.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl arachidonate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2566-89-4\/Methyl arachidonate\" target=\"_blank\" rel=\"noopener\">Methyl arachidonate<\/a><\/td><td class=\"oth\">51.66<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C20:4 (c5,c8,c11,c14)<\/td><\/tr>\n<tr><td class=\"num\">33.<\/td><td class=\"cmpd\">Methyl docosadienoate<\/td><td class=\"oth\">52.75<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C22:2 (c13,c16)<\/td><\/tr>\n<tr><td class=\"num\">34.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl lignocerate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2442-49-1\/Methyl lignocerate\" target=\"_blank\" rel=\"noopener\">Methyl lignocerate<\/a><\/td><td class=\"oth\">53.16<\/td><td class=\"oth\">40<\/td><td class=\"oth\">C24:0<\/td><\/tr>\n<tr><td class=\"num\">35.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl eicosapentaenoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2734-47-6\/Methyl eicosapentaenoate\" target=\"_blank\" rel=\"noopener\">Methyl eicosapentaenoate<\/a><\/td><td class=\"oth\">53.77<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C20:5 (c5,c8,c11,c14,c17)<\/td><\/tr>\n<tr><td class=\"num\">36.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl nervonate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2733-88-2\/Methyl nervonate\" target=\"_blank\" rel=\"noopener\">Methyl nervonate<\/a><\/td><td class=\"oth\">54.33<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C24:1 (C15)<\/td><\/tr>\n<tr><td class=\"num\">37.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl docosahexaenoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2566-90-7\/Methyl docosahexaenoate\" target=\"_blank\" rel=\"noopener\">Methyl docosahexaenoate<\/a><\/td><td class=\"oth\">58.48<\/td><td class=\"oth\">20<\/td><td class=\"oth\">C22:6 (c4,c7,c10,c13,c16,c19)<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rt-2560, 100 m, 0.25 mm ID, 0.20 \u00b5m (<a target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/13198?utm_source=chromatograms&amp;utm_medium=link&amp;utm_campaign=GC_FF1263\" rel=\"noopener\">cat.# 13198<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Food industry FAME mix (<a target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/35077?utm_source=chromatograms&amp;utm_medium=link&amp;utm_campaign=GC_FF1263\" rel=\"noopener\">cat.# 35077<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Hexane\/dichloromethane<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>1,000 \u00b5g\/mL<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 20:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Premium 4 mm Precision liner w\/wool (<a target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23305?utm_source=chromatograms&amp;utm_medium=link&amp;utm_campaign=GC_FF1263\" rel=\"noopener\">cat.# 23305<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>225 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>100 &#176;C (hold 4 min) to 250 &#176;C at 3 &#176;C\/min (hold 30 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.3 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>FID @ 285 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Make-up Gas Flow Rate:<\/th><td>30 mL\/min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Make-up Gas Type:<\/th><td>N<sub>2<\/sub> <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Hydrogen flow:<\/th><td>30 mL\/min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Air flow:<\/th><td>300 mL\/min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Data Rate:<\/th><td>50 Hz<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890B GC<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1263.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">New QC Test Ensures High-Quality, Detailed&nbsp;<em>cis\/trans<\/em>&nbsp;FAMEs Analysis<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In order to verify that the optimized process and original process both produce Rt-2560 columns of equivalent performance, a new application-specific QC test was designed and stringent specifications were set. The test mix used in the new QC test contains both saturated and unsaturated FAMEs that are commonly encountered in fats and oils analysis. Because every column manufactured under the improved process is tested, only high-performance columns suitable for detailed&nbsp;<em>cis\/trans<\/em>&nbsp;FAMEs analysis are certified for sale. Table I lists the components of the test mix and some of the chromatographic performance metrics that are calculated for each. Stationary phase bleed is measured at 250 \u00b0C following elution of the FAMEs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong>&nbsp;Application-specific components in the new QC test are used to verify the performance of Rt-2560 columns (cat.# 13198) by measuring critical chromatographic performance metrics. Components are listed in elution order.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Test Mix Component<\/strong><\/th><th><strong>Structural Nomenclature<\/strong><\/th><th><strong>Performance Metric<\/strong><\/th><\/tr><\/thead><tbody><tr><td>Methyl octadecanoate<\/td><td>C18:0<\/td><td>&nbsp;<\/td><\/tr><tr><td>Methyl elaidate<\/td><td>C18:1-c9<\/td><td>Retention index<\/td><\/tr><tr><td>Methyl oleate<\/td><td>C18:1-c9<\/td><td>&nbsp;<\/td><\/tr><tr><td>Methyl nonadecanoate<\/td><td>C19:0<\/td><td>&nbsp;<\/td><\/tr><tr><td>Methyl eicosanoate<\/td><td>C20:0<\/td><td>Retention factor<\/td><\/tr><tr><td>Methyl eicosenoate<\/td><td>C20:1-c11<\/td><td>Resolution with methyl linolenate<\/td><\/tr><tr><td>Methyl linolenate<\/td><td>C18:3-c9,c12,c15<\/td><td>Retention index<\/td><\/tr><tr><td>Methyl heneicosanoate<\/td><td>C21:0<\/td><td>&nbsp;<\/td><\/tr><tr><td>Methyl docosanoate<\/td><td>C22:0<\/td><td>Retention factor and efficiency<\/td><\/tr><tr><td>Methyl eicosatrienoate<\/td><td>C20:3-c11,c14,c17<\/td><td>Retention index<\/td><\/tr><tr><td>Methyl tricosanoate<\/td><td>C23:0<\/td><td>&nbsp;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">The retention index values measured for the series of unsaturated FAMES are used to characterize stationary phase selectivity and confirm that each column exhibits the same elution pattern and separation capabilities. These indices are measured using the bracketing provided by homologous saturated FAMEs, rather than by&nbsp;<em>n<\/em>-alkanes, in order to avoid potential interfacial adsorption effects on the highly polar stationary phase.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Efficiency and retention factor measurements are used to verify proper stationary phase deposition and consistent separation performance. Columns with low efficiency will show significantly reduced performance in the speciation of&nbsp;<em>trans<\/em>&nbsp;fat, particularly in the separation of the complex C18:1 region, and in the detailed profiling of unsaturated fatty acids.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The baseline resolution of methyl eicosenoate (C20:1-c11) and methyl linolenate (C18:3-c9,c12,c15) is a critical separation required by standard methods, such as AOAC 996.06 and AOCS Ce 1j-07, in order to demonstrate system suitability. Using an optimal column and standard conditions, C18:3-c9, c12, c15 elutes after C20:1-c11 with baseline resolution. If these conditions are met, peaks eluting between C20:0 and C20:1-c11 can be tentatively identified as C18:3 isomers containing at least one&nbsp;<em>trans<\/em>&nbsp;double bond. In Figure 2, the new QC test is analyzed on columns manufactured using the original and the optimized procedures. This comparison demonstrates that equivalent separation characteristics are obtained both before and after process improvement. In addition, Figure 2 shows baseline resolution of C20:1-c11 and C18:3-c9, c12, c15.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong>\u00a0Analysis of the FAMEs QC test mix confirms that Rt-2560 columns from before and after the manufacturing process redesign show equivalent separation characteristics. Baseline resolution of C20:1-c11 and C18:3-c9, c12, c15 as well as\u00a0<em>cis<\/em>\u00a0and\u00a0<em>trans<\/em>\u00a0C18:1-9 isomers is obtained on both columns.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ex1134.png\" alt=\"Unsaturated FAMES QC Test Mix on Rt-2560 Before Manufacturing Process Redesign\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EX1134<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(mg\/mL)<\/th><th style=\"text-align: center;width: 75px\">Structural Nomenclature<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl octadecanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/112-61-8\/Methyl octadecanoate\" target=\"_blank\" rel=\"noopener\">Methyl octadecanoate<\/a><\/td><td class=\"oth\">11.31<\/td><td class=\"oth\">1.1<\/td><td class=\"oth\">C18:0 <\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl elaidate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1937-62-8\/Methyl elaidate\" target=\"_blank\" rel=\"noopener\">Methyl elaidate<\/a><\/td><td class=\"oth\">12.24<\/td><td class=\"oth\">0.8<\/td><td class=\"oth\">C18:1 (t9)<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl oleate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/112-62-9\/Methyl oleate\" target=\"_blank\" rel=\"noopener\">Methyl oleate<\/a><\/td><td class=\"oth\">12.67<\/td><td class=\"oth\">0.6<\/td><td class=\"oth\">C18:1 (c9) <\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl nonadecanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1731-94-8\/Methyl nonadecanoate\" target=\"_blank\" rel=\"noopener\">Methyl nonadecanoate<\/a><\/td><td class=\"oth\">13.40<\/td><td class=\"oth\">1.1<\/td><td class=\"oth\">C19:0 <\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl eicosanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1120-28-1\/Methyl eicosanoate\" target=\"_blank\" rel=\"noopener\">Methyl eicosanoate<\/a><\/td><td class=\"oth\">16.13<\/td><td class=\"oth\">1.1<\/td><td class=\"oth\">C20:0 <\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(mg\/mL)<\/th><th style=\"text-align: center;width: 75px\">Structural Nomenclature<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl eicosenoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2390-09-2\/Methyl eicosenoate\" target=\"_blank\" rel=\"noopener\">Methyl eicosenoate<\/a><\/td><td class=\"oth\">18.25<\/td><td class=\"oth\">0.6<\/td><td class=\"oth\">C20:1 (c11) <\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl linolenate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/301-00-8\/Methyl linolenate\" target=\"_blank\" rel=\"noopener\">Methyl linolenate<\/a><\/td><td class=\"oth\">18.64<\/td><td class=\"oth\">0.8<\/td><td class=\"oth\">C18:3 (c9,c12,c15)<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl heneicosanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/6064-90-0\/Methyl heneicosanoate\" target=\"_blank\" rel=\"noopener\">Methyl heneicosanoate<\/a><\/td><td class=\"oth\">19.70<\/td><td class=\"oth\">1.1<\/td><td class=\"oth\">C21:0 <\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl docosanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/929-77-1\/Methyl docosanoate\" target=\"_blank\" rel=\"noopener\">Methyl docosanoate<\/a><\/td><td class=\"oth\">24.39<\/td><td class=\"oth\">1.1<\/td><td class=\"oth\">C22:0 <\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\">Methyl eicosatrienoate<\/td><td class=\"oth\">27.93<\/td><td class=\"oth\">0.6<\/td><td class=\"oth\">C20:3 (c11,c14,c17) <\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl tricosanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2433-97-8\/Methyl tricosanoate\" target=\"_blank\" rel=\"noopener\">Methyl tricosanoate<\/a><\/td><td class=\"oth\">30.54<\/td><td class=\"oth\">1.1<\/td><td class=\"oth\">C23:0<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rt-2560, 100 m, 0.25 mm ID, 0.20 \u00b5m<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Unsaturated FAMES QC test mix <\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Hexane<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 200:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Premium 4 mm Precision liner w\/wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23305\" rel=\"noopener\">cat.# 23305<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>180 &#176;C (hold 40 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>H<sub>2<\/sub>, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>2.5 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>FID @ 275 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Make-up Gas Flow Rate:<\/th><td>50 mL\/min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Make-up Gas Type:<\/th><td>N<sub>2<\/sub> <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Hydrogen flow:<\/th><td>40 mL\/min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Air flow:<\/th><td>400 mL\/min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Data Rate:<\/th><td>50 Hz<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890B GC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>GC column cat.# 13199 was used to produce this chromatogram, but it has since been discontinued. For assistance choosing a column for this application, contact Restek Technical Service or your local Restek representative.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>23305<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ex1134.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>After Redesign<\/strong><\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_qa0099.png\" alt=\"Unsaturated FAMES QC Test Mix on Rt-2560\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_QA0099<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(mg\/mL)<\/th><th style=\"text-align: center;width: 75px\">Structural Nomenclature<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl octadecanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/112-61-8\/Methyl octadecanoate\" target=\"_blank\" rel=\"noopener\">Methyl octadecanoate<\/a><\/td><td class=\"oth\">11.68<\/td><td class=\"oth\">1.1<\/td><td class=\"oth\">C18:0 <\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl elaidate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1937-62-8\/Methyl elaidate\" target=\"_blank\" rel=\"noopener\">Methyl elaidate<\/a><\/td><td class=\"oth\">12.64<\/td><td class=\"oth\">0.8<\/td><td class=\"oth\">C18:1 (t9)<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl oleate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/112-62-9\/Methyl oleate\" target=\"_blank\" rel=\"noopener\">Methyl oleate<\/a><\/td><td class=\"oth\">13.09<\/td><td class=\"oth\">0.6<\/td><td class=\"oth\">C18:1 (c9) <\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl nonadecanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1731-94-8\/Methyl nonadecanoate\" target=\"_blank\" rel=\"noopener\">Methyl nonadecanoate<\/a><\/td><td class=\"oth\">13.84<\/td><td class=\"oth\">1.1<\/td><td class=\"oth\">C19:0 <\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl eicosanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1120-28-1\/Methyl eicosanoate\" target=\"_blank\" rel=\"noopener\">Methyl eicosanoate<\/a><\/td><td class=\"oth\">16.66<\/td><td class=\"oth\">1.1<\/td><td class=\"oth\">C20:0 <\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(mg\/mL)<\/th><th style=\"text-align: center;width: 75px\">Structural Nomenclature<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl eicosenoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2390-09-2\/Methyl eicosenoate\" target=\"_blank\" rel=\"noopener\">Methyl eicosenoate<\/a><\/td><td class=\"oth\">18.85<\/td><td class=\"oth\">0.6<\/td><td class=\"oth\">C20:1 (c11) <\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl linolenate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/301-00-8\/Methyl linolenate\" target=\"_blank\" rel=\"noopener\">Methyl linolenate<\/a><\/td><td class=\"oth\">19.20<\/td><td class=\"oth\">0.8<\/td><td class=\"oth\">C18:3 (c9,c12,c15) <\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl heneicosanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/6064-90-0\/Methyl heneicosanoate\" target=\"_blank\" rel=\"noopener\">Methyl heneicosanoate<\/a><\/td><td class=\"oth\">20.35<\/td><td class=\"oth\">1.1<\/td><td class=\"oth\">C21:0 <\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl docosanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/929-77-1\/Methyl docosanoate\" target=\"_blank\" rel=\"noopener\">Methyl docosanoate<\/a><\/td><td class=\"oth\">25.17<\/td><td class=\"oth\">1.1<\/td><td class=\"oth\">C22:0 <\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\">Methyl eicosatrienoate<\/td><td class=\"oth\">28.79<\/td><td class=\"oth\">0.6<\/td><td class=\"oth\">C20:3 (c11,c14,c17)<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl tricosanoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2433-97-8\/Methyl tricosanoate\" target=\"_blank\" rel=\"noopener\">Methyl tricosanoate<\/a><\/td><td class=\"oth\">31.49<\/td><td class=\"oth\">1.1<\/td><td class=\"oth\">C23:0<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rt-2560, 100 m, 0.25 mm ID, 0.20 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/13198\" rel=\"noopener\">cat.# 13198<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Unsaturated FAMES QC test mix <\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Hexane<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 200:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Premium 4 mm Precision liner w\/wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23305\" rel=\"noopener\">cat.# 23305<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>180 &#176;C (hold 40 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>H<sub>2<\/sub>, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>2.5 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>FID @ 275 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Make-up Gas Flow Rate:<\/th><td>50 mL\/min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Make-up Gas Type:<\/th><td>N<sub>2<\/sub> <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Hydrogen flow:<\/th><td>40 mL\/min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Air flow:<\/th><td>400 mL\/min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Data Rate:<\/th><td>50 Hz<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890B GC<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>13198<\/li><li>23305<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Detailed FAMES Analysis<\/li><li>FAMES<\/li><li>Fats and Oils<\/li><li>Fatty Acid Profiling<\/li><li>Nutritional Labeling<\/li><li>Trans Fats<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_qa0099.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The improved manufacturing process and application-specific QC test both ensure that Rt-2560 columns provide a consistently high level of performance for detailed&nbsp;<em>cis\/trans<\/em> FAMEs analysis and are suitable for standard methods of fat speciation in food, such as AOAC 996.06 and AOCS Ce 1j-07. Rt-2560 columns produced using the optimized process exhibit the same selectivity expected from a high cyanopropyl column with little column-to-column variability, while the new QC test ensures a high-quality product that meets method performance requirements.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Even minor variations in manufacturing processes can potentially have detrimental effects on column-to-column reproducibility. As shown here, Rt-2560 GC columns produced using a newly updated and optimized manufacturing process exhibit high reproducibility and provide consistent performance for detailed cis\/trans FAMEs analysis.<\/p>\n","protected":false},"author":35,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[7],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[455,513],"class_list":["post-43541","post","type-post","status-publish","format-standard","hentry","category-articles"],"acf":[],"taxonomy_info":{"category":[{"value":7,"label":"Articles"}]},"featured_image_src_large":false,"author_info":{"display_name":"Kristi Sellers","author_link":"https:\/\/discover.restek.com\/fr\/author\/kristi-sellers\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":7,"category_count":510,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":455,"user_id":35,"is_guest":0,"slug":"kristi-sellers","display_name":"Kristi Sellers","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-sellers-kristi.png","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-sellers-kristi.png"},"author_category":"1","first_name":"Kristi","last_name":"Sellers","user_url":"","job_title":"","description":"With over 30 years of experience in chromatography, Kristi has worked for Restek as an applications chemist with experience in both GC and LC method development. She has also worked as a QC chemist and a process chemist in addition to her managerial positions in GC Column manufacturing, QC, the Applied Science Group, and R&amp;D. Kristi is currently a senior product marketing manager for GC columns. She holds a BS in chemistry from Lock Haven University, an MBA from Regis University, and has been a Restek seminar instructor for more than three decades."},{"term_id":513,"user_id":0,"is_guest":1,"slug":"becca-stevens","display_name":"Rebecca Stevens","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Rebecca","last_name":"Stevens","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43541","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/35"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=43541"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43541\/revisions"}],"predecessor-version":[{"id":85331,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43541\/revisions\/85331"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=43541"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=43541"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=43541"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=43541"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=43541"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=43541"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=43541"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=43541"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=43541"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}