{"id":43561,"date":"2021-01-12T13:30:00","date_gmt":"2021-01-12T13:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/analyse-rapide-et-directe-dacides-amines-non-derives-dans-les-preparations-pour-nourrissons\/"},"modified":"2026-01-28T19:17:20","modified_gmt":"2026-01-28T19:17:20","slug":"analyse-rapide-et-directe-dacides-amines-non-derives-dans-les-preparations-pour-nourrissons","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/articles-fr\/fffa3436-fr\/analyse-rapide-et-directe-dacides-amines-non-derives-dans-les-preparations-pour-nourrissons","title":{"rendered":"Analyse rapide et directe d\u2019acides amin\u00e9s non-d\u00e9riv\u00e9s dans les pr\u00e9parations pour nourrissons"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>Pr\u00e9paration d\u2019\u00e9chantillon simple, en une \u00e9tape, pour l\u2019analyse directe d\u2019acides amin\u00e9s non-d\u00e9riv\u00e9s.<\/li>\n\n\n\n<li>Analyse simultan\u00e9e d\u2019acides amin\u00e9s polaires, non polaires, charg\u00e9s positivement et charg\u00e9s n\u00e9gativement, sur un cycle d\u2019analyse court de 10 minutes.<\/li>\n\n\n\n<li>Le gradient sp\u00e9cifiquement d\u00e9velopp\u00e9 permet de s\u00e9parer les contaminants des analytes d\u2019int\u00e9r\u00eat.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Pour garantir la satisfaction des besoins nutritionnels, on a besoin de m\u00e9thodes analytiques fiables pour une d\u00e9termination pr\u00e9cise des acides amin\u00e9s libres dans les pr\u00e9parations pour nourrissons. La d\u00e9rivation pr\u00e9-colonne, suivie d\u2019une d\u2019analyse LC en phase inverse, est une approche typique, cette d\u00e9rivation \u00e9tant n\u00e9cessaire en raison d\u2019une faible r\u00e9tention chromatographique et d\u2019une mauvaise sensibilit\u00e9 pour les acides amin\u00e9s libres. Mais ces m\u00e9thodes sont souvent chronophages et assez laborieuses. L\u2019utilisation d\u2019acides perfluor\u00e9s comme r\u00e9actifs d\u2019appariement d\u2019ions, afin d\u2019am\u00e9liorer la r\u00e9tention des acides amin\u00e9s non-d\u00e9riv\u00e9s sur une colonne C18, est une autre technique courante, mais ce genre d\u2019analyses peut avoir un impact n\u00e9gatif sur le syst\u00e8me chromatographique et le spectrom\u00e8tre de masse.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019approche pr\u00e9sent\u00e9e ici est plus simple, car les acides amin\u00e9s non-d\u00e9riv\u00e9s peuvent \u00eatre analys\u00e9s directement en LC-MS\/MS \u2013 suivant une pr\u00e9paration d\u2019\u00e9chantillons simple en une seule \u00e9tape \u2013 en utilisant une colonne Raptor Polar X. Les colonnes Raptor Polar X sont faites d\u2019une phase hybride (HILIC et \u00c9change Ionique) utilisant diff\u00e9rents m\u00e9canismes d\u2019interactions qui fournissent la r\u00e9tention et la r\u00e9solution n\u00e9cessaires \u00e0 l\u2019analyse simultan\u00e9e d\u2019une grande vari\u00e9t\u00e9 de compos\u00e9s aux chimies et structures diff\u00e9rentes. Comme d\u00e9montr\u00e9 ici, des acides amin\u00e9s non-d\u00e9riv\u00e9s aux cha\u00eenes lat\u00e9rales polaires, non polaires, charg\u00e9es positivement et charg\u00e9es n\u00e9gativement, ont \u00e9t\u00e9 correctement retenus et s\u00e9par\u00e9s avec<br>un gradient court de 10 minutes. Ce dernier a \u00e9galement permis de s\u00e9parer les contaminants du syst\u00e8me des analytes d\u2019int\u00e9r\u00eat, augmentant la robustesse de la m\u00e9thode. En suivant cette m\u00e9thode, les proc\u00e9dures de pr\u00e9paration d\u2019\u00e9chantillons chronophages et laborieuses, qui peuvent inclure de co\u00fbteux kits de d\u00e9rivation, sont remplac\u00e9es par une simple pr\u00e9cipitation de prot\u00e9ines puis une analyse directe de l\u2019extrait. L\u2019analyse directe d\u2019acides amin\u00e9s non-d\u00e9riv\u00e9s sur une colonne Raptor Polar X fournit d\u2019excellents r\u00e9sultats, tout en restant simple et rapide, ce qui en fait une alternative tr\u00e8s avantageuse aux m\u00e9thodes traditionnelles.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ff0579.png\" alt=\"Underivatized Amino Acids Analysis in Baby Formula on Raptor Polar X\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FF0579<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tryptophan\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/54-12-6\/Tryptophan\" target=\"_blank\" rel=\"noopener\">Tryptophan<\/a><\/td><td class=\"oth\">1.17<\/td><td class=\"oth\">205.07<\/td><td class=\"oth\">146.08<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenylalanine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/63-91-2\/Phenylalanine\" target=\"_blank\" rel=\"noopener\">Phenylalanine<\/a><\/td><td class=\"oth\">1.26<\/td><td class=\"oth\">166.13<\/td><td class=\"oth\">120.10<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Leucine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/61-90-5\/Leucine\" target=\"_blank\" rel=\"noopener\">Leucine<\/a><\/td><td class=\"oth\">1.41<\/td><td class=\"oth\">132.13<\/td><td class=\"oth\">86.10<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isoleucine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/73-32-5\/Isoleucine\" target=\"_blank\" rel=\"noopener\">Isoleucine<\/a><\/td><td class=\"oth\">1.55<\/td><td class=\"oth\">132.13<\/td><td class=\"oth\">86.10<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methionine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59-51-8\/Methionine\" target=\"_blank\" rel=\"noopener\">Methionine<\/a><\/td><td class=\"oth\">1.62<\/td><td class=\"oth\">150.07<\/td><td class=\"oth\">104.10<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tyrosine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/556-03-6\/Tyrosine\" target=\"_blank\" rel=\"noopener\">Tyrosine<\/a><\/td><td class=\"oth\">1.69<\/td><td class=\"oth\">182.10<\/td><td class=\"oth\">136.08<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Taurine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/107-35-7\/Taurine\" target=\"_blank\" rel=\"noopener\">Taurine<\/a><\/td><td class=\"oth\">1.91<\/td><td class=\"oth\">126.07<\/td><td class=\"oth\">108.07<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Valine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/516-06-3\/Valine\" target=\"_blank\" rel=\"noopener\">Valine<\/a><\/td><td class=\"oth\">1.98<\/td><td class=\"oth\">118.13<\/td><td class=\"oth\">72.11<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Proline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/609-36-9\/Proline\" target=\"_blank\" rel=\"noopener\">Proline<\/a><\/td><td class=\"oth\">2.29<\/td><td class=\"oth\">116.13<\/td><td class=\"oth\">70.09<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Alanine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/302-72-7\/Alanine\" target=\"_blank\" rel=\"noopener\">Alanine<\/a><\/td><td class=\"oth\">3.00<\/td><td class=\"oth\">90.03<\/td><td class=\"oth\">44.10<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Threonine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/80-68-2\/Threonine\" target=\"_blank\" rel=\"noopener\">Threonine<\/a><\/td><td class=\"oth\">3.12<\/td><td class=\"oth\">120.13<\/td><td class=\"oth\">74.08<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Glycine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-40-6\/Glycine\" target=\"_blank\" rel=\"noopener\">Glycine<\/a><\/td><td class=\"oth\">3.62<\/td><td class=\"oth\">76.10<\/td><td class=\"oth\">30.11<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Glutamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-85-9\/Glutamine\" target=\"_blank\" rel=\"noopener\">Glutamine<\/a><\/td><td class=\"oth\">3.87<\/td><td class=\"oth\">147.13<\/td><td class=\"oth\">84.07<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Serine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/302-84-1\/Serine\" target=\"_blank\" rel=\"noopener\">Serine<\/a><\/td><td class=\"oth\">3.93<\/td><td class=\"oth\">106.07<\/td><td class=\"oth\">60.09<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Asparagine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/70-47-3\/Asparagine\" target=\"_blank\" rel=\"noopener\">Asparagine<\/a><\/td><td class=\"oth\">4.08<\/td><td class=\"oth\">133.13<\/td><td class=\"oth\">74.07<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Arginine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/74-79-3\/Arginine\" target=\"_blank\" rel=\"noopener\">Arginine<\/a><\/td><td class=\"oth\">4.47<\/td><td class=\"oth\">175.17<\/td><td class=\"oth\">70.09<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Histidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/71-00-1\/Histidine\" target=\"_blank\" rel=\"noopener\">Histidine<\/a><\/td><td class=\"oth\">4.66<\/td><td class=\"oth\">156.07<\/td><td class=\"oth\">110.16<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Lysine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-87-1\/Lysine\" target=\"_blank\" rel=\"noopener\">Lysine<\/a><\/td><td class=\"oth\">4.97<\/td><td class=\"oth\">147.13<\/td><td class=\"oth\">84.13<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Glutamic acid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/617-65-2\/Glutamic acid\" target=\"_blank\" rel=\"noopener\">Glutamic acid<\/a><\/td><td class=\"oth\">5.89<\/td><td class=\"oth\">148.10<\/td><td class=\"oth\">84.10<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cystine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-89-3\/Cystine\" target=\"_blank\" rel=\"noopener\">Cystine<\/a><\/td><td class=\"oth\">6.10<\/td><td class=\"oth\">241.13<\/td><td class=\"oth\">152.00<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aspartic acid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/617-45-8\/Aspartic acid\" target=\"_blank\" rel=\"noopener\">Aspartic acid<\/a><\/td><td class=\"oth\">7.12<\/td><td class=\"oth\">134.07<\/td><td class=\"oth\">74.06<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor Polar X  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9311A12\" rel=\"noopener\">cat.# 9311A12<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>30 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>20:80 Water:acetonitrile, 0.01 N HCl<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>  Endogenous amino acids<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 0.5% formic acid <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Mobile Phase B: 9:1 Acetonitrile:20 mM ammonium formate in water (pH 3.0) (The ammonium formate concentration is 20 mM relative to the total volume of mobile phase B. See preparation notes for instructions on diluting a 200 mM aqueous starting solution.) <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.5<\/td><td>12<\/td><td>88<\/td><\/tr><tr><td>3.50<\/td><td>0.5<\/td><td>12<\/td><td>88<\/td><\/tr><tr><td>8.00<\/td><td>0.5<\/td><td>70<\/td><td>30<\/td><\/tr><tr><td>8.01<\/td><td>0.5<\/td><td>12<\/td><td>88<\/td><\/tr><tr><td>10.0<\/td><td>0.5<\/td><td>12<\/td><td>88<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>UHPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>A 200 \u00b5L aliquot of protein hydrolysate formula (Similac ALIMENTUM) was mixed with 800 \u00b5L of acetonitrile and 10 \u00b5L of 1 N HCl. After centrifugation at 4000 rpm for 5 minutes, the supernatant was diluted 20-fold with 20:80 water:acetonitrile (0.01 N HCl) and injected for analysis.<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td><i>Mobile Phase B Preparation:<\/i> To make 500 mL of mobile phase B, measure ~45 mL of water into a small beaker and add 1 mL of 10 M ammonium formate solution. Adjust pH to 3.0 by adding formic acid and then bring the volume to 50 mL with water. Combine this 50 mL ammonium formate solution (pH 3.0) with 450 mL of acetonitrile to complete the preparation.   <\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9311A12<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>amino acid<\/li><li>amino acids<\/li><li>underivatized<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ff0579.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Cette analyse directe par LC-MS\/MS d\u2019acides amin\u00e9s non-d\u00e9riv\u00e9s dans les pr\u00e9parations pour nourrissons fournit d\u2019excellents r\u00e9sultats, tout en restant simple et rapide pour une d\u00e9termination pr\u00e9cise d&#8217;une large gamme d&#8217;acides amin\u00e9s libres.<\/p>\n","protected":false},"author":11,"featured_media":90020,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[462],"tags":[],"industries-application":[2214,2215],"post-badge":[],"resource-type":[],"product-library":[2463,2445],"resource-technique":[2318,2362],"ppma_author":[414],"class_list":["post-43561","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-fr","industries-application-industrie-agroalimentaire","industries-application-qualite-alimentaire","product-library-colonnes-lc","product-library-produits-pour-la-chromatographie-en-phase-liquide","resource-technique-chromatographie-en-phase-liquide","resource-technique-ms-ms-fr"],"acf":[],"taxonomy_info":{"category":[{"value":462,"label":"Articles"}],"industries-application":[{"value":2214,"label":"Industrie Agroalimentaire"},{"value":2215,"label":"Qualit\u00e9 Alimentaire"}],"product-library":[{"value":2463,"label":"Colonnes LC"},{"value":2445,"label":"Produits pour la chromatographie en phase liquide"}],"resource-technique":[{"value":2318,"label":"Chromatographie en phase liquide"},{"value":2362,"label":"MS\/MS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-fffa3436-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":462,"name":"Articles","slug":"articles-fr","term_group":0,"term_taxonomy_id":462,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":462,"category_count":511,"category_description":"","cat_name":"Articles","category_nicename":"articles-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43561","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=43561"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43561\/revisions"}],"predecessor-version":[{"id":85659,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43561\/revisions\/85659"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/90020"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=43561"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=43561"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=43561"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=43561"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=43561"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=43561"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=43561"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=43561"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=43561"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}