{"id":43605,"date":"2021-01-12T00:00:00","date_gmt":"2021-01-12T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/analyse-rapide-et-robuste-de-pesticides-polaires-dans-les-epinards\/"},"modified":"2026-01-28T19:17:45","modified_gmt":"2026-01-28T19:17:45","slug":"analyse-rapide-et-robuste-de-pesticides-polaires-dans-les-epinards","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/articles-fr\/fsfa3215-fr\/analyse-rapide-et-robuste-de-pesticides-polaires-dans-les-epinards","title":{"rendered":"Analyse rapide et robuste de pesticides polaires dans les \u00e9pinards"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>Aucune d\u00e9rivation chronophage, pas de technique complexe d\u2019appariement d\u2019ions, et des temps d\u2019\u00e9quilibration tr\u00e8s courts.<\/li>\n\n\n\n<li>La phase stationnaire unique offre une excellente r\u00e9tention, r\u00e9sultant en de meilleures formes\/sym\u00e9tries de pics.<\/li>\n\n\n\n<li>La robustesse de la colonne garantit des r\u00e9sultats chromatographiques fiables.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019analyse directe de pesticides polaires, comme le glyphosate, son principal m\u00e9tabolite l\u2019AMPA, et le glufosinate, est complexe car ces compos\u00e9s sont tr\u00e8s peu retenus sur des colonnes de phase inverse, et leur possible ch\u00e9lation avec les ions m\u00e9talliques pr\u00e9sents dans le syst\u00e8me LC-MS\/MS peut consid\u00e9rablement r\u00e9duire leur signal et donc la sensibilit\u00e9. On utilise souvent des r\u00e9actifs de d\u00e9rivation ou d\u2019appariement d\u2019ions pour am\u00e9liorer les performances chromatographiques mais ces r\u00e9actifs n\u00e9cessitent un temps de pr\u00e9paration d\u2019\u00e9chantillons suppl\u00e9mentaire et peuvent avoir des effets secondaires d\u00e9favorables (pr\u00e9cipit\u00e9s, longs temps d\u2019\u00e9quilibration, contamination du syst\u00e8me, etc.).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Utiliser une colonne Raptor Polar X est la meilleure solution car cette nouvelle phase stationnaire offre une interaction plus forte avec les compos\u00e9s anioniques polaires. Elle propose un mode de r\u00e9tention hybride (HILIC et \u00c9change Ionique) et offre une bonne r\u00e9tention tout en permettant aux compos\u00e9s d\u2019\u00eatre rapidement \u00e9lu\u00e9s sous forme de pics sym\u00e9triques, et ce gr\u00e2ce \u00e0 de simples changements de phase mobile. Dans cette analyse de pesticides polaires dans les \u00e9pinards, on observe d\u2019excellentes performances chromatographiques pour les trois compos\u00e9s, avec un temps total d\u2019analyse de seulement huit minutes.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0547.png\" alt=\"Polar Pesticides in Spinach on Raptor Polar X by LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FS0547<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion 1<\/th><th style=\"text-align: center;width: 75px\">Product Ion 2<\/th><th style=\"text-align: center;width: 75px\">Product Ion 3<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\">AMPA<\/td><td class=\"oth\">100<\/td><td class=\"oth\">110.10<\/td><td class=\"oth\">79.05<\/td><td class=\"oth\">63.10<\/td><td class=\"oth\">81.10<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Glufosinate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51276-47-2\/Glufosinate\" target=\"_blank\" rel=\"noopener\">Glufosinate<\/a><\/td><td class=\"oth\">100<\/td><td class=\"oth\">180.20<\/td><td class=\"oth\">85.15<\/td><td class=\"oth\">95.10<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Glyphosate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1071-83-6\/Glyphosate\" target=\"_blank\" rel=\"noopener\">Glyphosate<\/a><\/td><td class=\"oth\">100<\/td><td class=\"oth\">168.10<\/td><td class=\"oth\">63.05<\/td><td class=\"oth\">79.05<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor Polar X  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9311A32\" rel=\"noopener\">cat.# 9311A32<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>30 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>Raptor Polar X guard column cartridge 5 mm, 2.1 mm ID, 2.7 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9311A0252\" rel=\"noopener\">cat.# 9311A0252<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>35 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Spinach extract<\/td><\/tr>\n<td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>2 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water,  0.5% formic acid <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Acetonitrile, 0.5% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.5<\/td><td>35<\/td><td>65<\/td><\/tr><tr><td>5.0<\/td><td>0.5<\/td><td>90<\/td><td>10<\/td><\/tr><tr><td>6.5<\/td><td>0.5<\/td><td>90<\/td><td>10<\/td><\/tr><tr><td>6.51<\/td><td>0.5<\/td><td>35<\/td><td>65<\/td><\/tr><tr><td>8<\/td><td>0.5<\/td><td>35<\/td><td>65<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>UHPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Frozen spinach was added to a Blixer processor with dry ice (3:1-4:1 ratio) and then ground into a very fine powder. The homogenate was placed into the freezer immediately. A 5.0 gram sample of the spinach powder was weighed into a 50 mL centrifuge tube (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/25846\" rel=\"noopener\">cat.# 25846<\/a>). According to the QuPPe method (Quick Polar Pesticides Method), 5.0 mL of methanol with 1.0% formic acid was added into the centrifuge tube. The tube was shaken by hand for 1 min and then by a mechanical shaker vigorously for 5 min. After centrifuging for 10 min at 4200 rpm, the supernatant was filtered through a 0.22 \u03bcm filter (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23984\" rel=\"noopener\">cat.# 23984<\/a>). The final extract was fortified with the AMPA, glufosinate, and glyphosate at a final concentration of 100 ng\/mL.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9311A0252<\/li><li>9311A32<\/li><li>25846<\/li><li>23984<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0547.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Cette analyse LC-MS\/MS simple et rapide des pesticides polaires dans les \u00e9pinards offre e une excellente r\u00e9tention, r\u00e9sultant en de meilleures formes\/sym\u00e9tries de pics apr\u00e8s des centaines dinjections de matrice sur une colonne Raptor Polar X.<\/p>\n","protected":false},"author":11,"featured_media":70562,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[462],"tags":[],"industries-application":[2214,2216],"post-badge":[],"resource-type":[],"product-library":[2463,2445],"resource-technique":[2318,2362],"ppma_author":[414],"class_list":["post-43605","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-fr","industries-application-industrie-agroalimentaire","industries-application-securite-alimentaire","product-library-colonnes-lc","product-library-produits-pour-la-chromatographie-en-phase-liquide","resource-technique-chromatographie-en-phase-liquide","resource-technique-ms-ms-fr"],"acf":[],"taxonomy_info":{"category":[{"value":462,"label":"Articles"}],"industries-application":[{"value":2214,"label":"Industrie Agroalimentaire"},{"value":2216,"label":"S\u00e9curit\u00e9 alimentaire"}],"product-library":[{"value":2463,"label":"Colonnes LC"},{"value":2445,"label":"Produits pour la chromatographie en phase liquide"}],"resource-technique":[{"value":2318,"label":"Chromatographie en phase liquide"},{"value":2362,"label":"MS\/MS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-FSFA3215-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":462,"name":"Articles","slug":"articles-fr","term_group":0,"term_taxonomy_id":462,"taxonomy":"category","description":"","parent":0,"count":509,"filter":"raw","cat_ID":462,"category_count":509,"category_description":"","cat_name":"Articles","category_nicename":"articles-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43605","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=43605"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43605\/revisions"}],"predecessor-version":[{"id":85660,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43605\/revisions\/85660"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/70562"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=43605"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=43605"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=43605"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=43605"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=43605"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=43605"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=43605"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=43605"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=43605"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}