{"id":43611,"date":"2021-03-22T00:00:00","date_gmt":"2021-03-22T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/accelerez-vos-analyses-de-multi-residus-de-pesticides-dans-les-aliments-avec-la-gc-ms-basse-pression\/"},"modified":"2026-10-02T13:53:58","modified_gmt":"2026-10-02T13:53:58","slug":"accelerez-vos-analyses-de-multi-residus-de-pesticides-dans-les-aliments-avec-la-gc-ms-basse-pression","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/articles-fr\/fsfa3504-fr\/accelerez-vos-analyses-de-multi-residus-de-pesticides-dans-les-aliments-avec-la-gc-ms-basse-pression","title":{"rendered":"Acc\u00e9l\u00e9rez vos analyses de multi-r\u00e9sidus de pesticides dans les aliments avec la GC-MS basse pression"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>Analyse des multi-r\u00e9sidus de pesticides dans les aliments 3 fois plus rapide.<\/li>\n\n\n\n<li>Le kit LPGC, assembl\u00e9 en usine et garanti sans fuites, s\u2019installe aussi simplement qu\u2019une colonne.<\/li>\n\n\n\n<li>Id\u00e9al pour les m\u00e9thodes d\u2019analyse GC-MS et fast GC-MS\/MS.<\/li>\n\n\n\n<li>La ligne de transfert int\u00e9gr\u00e9e r\u00e9duit le bruit de fond et le temps de stabilisation.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019analyse des multi-r\u00e9sidus de pesticides est au coeur de la s\u00e9curit\u00e9 alimentaire et les laboratoires sont g\u00e9n\u00e9ralement sous pression du fait des grandes quantit\u00e9s d\u2019\u00e9chantillons \u00e0 analyser dans des d\u00e9lais tr\u00e8s courts. Ils sont donc toujours \u00e0 la recherche de m\u00e9thodes GC-MS et GC-MS\/ MS plus rapides, mais l\u2019approche habituelle n\u00e9cessite des instruments tr\u00e8s on\u00e9reux ou des techniques de \u00ab GC rapide \u00bb qui pr\u00e9sentent des probl\u00e8mes de capacit\u00e9 ou de compatibilit\u00e9 avec MS (lorsque l\u2019hydrog\u00e8ne est utilis\u00e9 comme gaz vecteur). La GC-MS basse pression (LPGC-MS) est une option qui permet d\u2019obtenir un gain de rapidit\u00e9 significatif sans ces inconv\u00e9nients mais jusqu\u2019\u00e0 pr\u00e9sent, sa mise en oeuvre difficile faisait obstacle \u00e0 son adoption. Comme le montre cette analyse de pesticides par LPGC-MS qui porte sur 209 compos\u00e9s dans les fraises, tous les analytes \u00e9luent rapidement, avec 8,33 minutes pour la deltam\u00e9thrine. Ce temps est trois fois plus rapide que notre analyse du m\u00eame extrait sur une colonne de type 5 de 30 m, DI 0,25 mm, 0,25 \u03bcm, o\u00f9 la deltam\u00e9thrine \u00e9tait d\u00e9j\u00e0 le dernier compos\u00e9, avec une \u00e9lution \u00e0 26,34 minutes.<br><br>Cette analyse des pesticides par LPGC-MS utilise un kit de colonnes GC basse pression unique qui se compose d\u2019une colonne r\u00e9ductrice \u00e9troite (5 m x DI 0,18 mm) coupl\u00e9e en usine avec une colonne analytique Rtx-5ms plus large (15 m, DI 0,53 mm, 1 \u03bcm plus 1 m de ligne de transfert int\u00e9gr\u00e9e \u00e0 la sortie). Le raccordement \u00e9tabli en usine est test\u00e9 pour garantir une \u00e9tanch\u00e9it\u00e9 parfaite et il est plus robuste que les raccordements manuels. Ce kit permet d\u2019obtenir les gains de rapidit\u00e9 inh\u00e9rents \u00e0 la LPGC-MS au moyen d\u2019un simple changement de colonne et d\u2019une mise \u00e0 jour de la m\u00e9thode de l\u2019instrument avec les dimensions de la nouvelle colonne, la vitesse de mont\u00e9e en temp\u00e9rature et les d\u00e9bits. \u00c0 noter que pour cette analyse de pesticides par LPGC-MS en particulier, le four GC doit \u00eatre capable de monter en temp\u00e9rature \u00e0 une vitesse de 35 \u00b0C\/min, m\u00eame au-del\u00e0 de 300 \u00b0C. Pour les fours fonctionnant sous 120V, un kit &#8220;Oven Accelerator&#8221; est n\u00e9cessaire pour atteindre cette vitesse.<br><br>Cette configuration de LPGC-MS offre un gain de vitesse significatif mais aussi des pics hauts et \u00e9troits qui peuvent am\u00e9liorer la sensibilit\u00e9, ainsi qu\u2019une grande capacit\u00e9 gr\u00e2ce \u00e0 l\u2019\u00e9paisseur de film dans la colonne analytique. En revanche, le nombre de plateaux th\u00e9oriques est l\u00e9g\u00e8rement inf\u00e9rieur \u00e0 celui des colonnes traditionnelles. Bien que la r\u00e9solution des pics soit inf\u00e9rieure avec la LPGC-MS, le spectrom\u00e8tre de masse peut compenser cet effet en permettant une distinction spectrale de la plupart des analytes cibles. Toutefois, il est important de noter que les compos\u00e9s isobares doivent \u00eatre s\u00e9par\u00e9s par la chromatographie car la MS ne peut pas les r\u00e9soudre. Par exemple, dans cette analyse, les isobares 4-4\u2019-DDD et 2,4\u2019-DDT ne sont pas enti\u00e8rement r\u00e9solus. Si leur s\u00e9paration est critique, alors le d\u00e9veloppement de la m\u00e9thode doit \u00eatre approfondi. Les autres s\u00e9parations pr\u00e9sent\u00e9es concernent des compos\u00e9s qui pr\u00e9sentent des transitions ioniques \u00e0 la fois partag\u00e9es et uniques (trifluraline\/benfluraline et cyhalothrine\/acrinathrine), qui sont s\u00e9par\u00e9s de mani\u00e8re ad\u00e9quate (perm\u00e9thrine cis et trans), ou qui sont couramment pr\u00e9sent\u00e9s comme un groupe (groupes d\u2019isom\u00e8res de la cyfluthrine et de la cyperm\u00e9thrine) et qui restent donc quantifiables&nbsp; m\u00eame si la chromatographie ne permet pas leur r\u00e9solution compl\u00e8te.<br><br>Pour les laboratoires d\u2019analyses alimentaires \u00e0 la recherche de m\u00e9thodes plus rapides, les gains de temps d\u2019analyse de pesticides par LPGC-MS sont un moyen efficace d\u2019augmenter la cadence de traitement des \u00e9chantillons. Cette configuration autrefois compliqu\u00e9e est d\u00e9sormais bien plus simple \u00e0 mettre en oeuvre avec le kit de colonnes GC basse pression de Restek.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_fs0572.png\" alt=\"200+ Pesticides in Strawberry on Low-Pressure GC Column Kit\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FS0572<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><th style=\"text-align: center;width: 75px\">Collision Energy<\/th><th style=\"text-align: center;width: 75px\">Confirmation Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Confirmation Product Ion<\/th><th style=\"text-align: center;width: 75px\">Collision Energy<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Allidochlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/93-71-0\/Allidochlor\" target=\"_blank\" rel=\"noopener\">Allidochlor<\/a><\/td><td class=\"oth\">3.37<\/td><td class=\"oth\">138<\/td><td class=\"oth\">81<\/td><td class=\"oth\">8<\/td><td class=\"oth\">132<\/td><td class=\"oth\">56<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dichlobenil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1194-65-6\/Dichlobenil\" target=\"_blank\" rel=\"noopener\">Dichlobenil<\/a><\/td><td class=\"oth\">3.63<\/td><td class=\"oth\">171<\/td><td class=\"oth\">100<\/td><td class=\"oth\">25<\/td><td class=\"oth\">136<\/td><td class=\"oth\">100.1<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Biphenyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92-52-4\/Biphenyl\" target=\"_blank\" rel=\"noopener\">Biphenyl<\/a><\/td><td class=\"oth\">3.75<\/td><td class=\"oth\">154.1<\/td><td class=\"oth\">115<\/td><td class=\"oth\">25<\/td><td class=\"oth\">152.1<\/td><td class=\"oth\">126.1<\/td><td class=\"oth\">23<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mevinphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7786-34-7\/Mevinphos\" target=\"_blank\" rel=\"noopener\">Mevinphos<\/a><\/td><td class=\"oth\">3.88<\/td><td class=\"oth\">192<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">95<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3,4-Dichloroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-76-1\/3,4-Dichloroaniline\" target=\"_blank\" rel=\"noopener\">3,4-Dichloroaniline<\/a><\/td><td class=\"oth\">3.92<\/td><td class=\"oth\">163<\/td><td class=\"oth\">90<\/td><td class=\"oth\">16<\/td><td class=\"oth\">161<\/td><td class=\"oth\">126.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pebulate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1114-71-2\/Pebulate\" target=\"_blank\" rel=\"noopener\">Pebulate<\/a><\/td><td class=\"oth\">4.01<\/td><td class=\"oth\">203<\/td><td class=\"oth\">128<\/td><td class=\"oth\">8<\/td><td class=\"oth\">128<\/td><td class=\"oth\">57<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Etridiazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2593-15-9\/Etridiazole\" target=\"_blank\" rel=\"noopener\">Etridiazole<\/a><\/td><td class=\"oth\">4.02<\/td><td class=\"oth\">211<\/td><td class=\"oth\">139.9<\/td><td class=\"oth\">22<\/td><td class=\"oth\">182.8<\/td><td class=\"oth\">139.9<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\">&lt;a class=&quot;cmpd_link&quot; title=&quot;View compound information for <i>N<\/i>-(2,4-Dimethylphenyl) formamide&#8221; title=&#8221;View compound information for <i>N<\/i>-(2,4-Dimethylphenyl) formamide&#8221; href=&#8221;https:\/\/ez.restek.com\/compound\/view\/en\/60397-77-5\/<i>N-(2,4-Dimethylphenyl) formamide&#8221;&gt;<i>N<\/i>-(2,4-Dimethylphenyl) formamide<\/a><\/td><td class=\"oth\">4.10<\/td><td class=\"oth\">121<\/td><td class=\"oth\">106<\/td><td class=\"oth\">8<\/td><td class=\"oth\">120<\/td><td class=\"oth\">77<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tetrahydrophthalimide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1469-48-3\/Tetrahydrophthalimide\" target=\"_blank\" rel=\"noopener\">Tetrahydrophthalimide<\/a><\/td><td class=\"oth\">4.10<\/td><td class=\"oth\">151.1<\/td><td class=\"oth\">80.1<\/td><td class=\"oth\">6<\/td><td class=\"oth\">151.1<\/td><td class=\"oth\">122<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methacrifos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62610-77-9\/Methacrifos\" target=\"_blank\" rel=\"noopener\">Methacrifos<\/a><\/td><td class=\"oth\">4.19<\/td><td class=\"oth\">240<\/td><td class=\"oth\">180<\/td><td class=\"oth\">10<\/td><td class=\"oth\">125<\/td><td class=\"oth\">79<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chloroneb\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2675-77-6\/Chloroneb\" target=\"_blank\" rel=\"noopener\">Chloroneb<\/a><\/td><td class=\"oth\">4.24<\/td><td class=\"oth\">206<\/td><td class=\"oth\">191<\/td><td class=\"oth\">10<\/td><td class=\"oth\">191<\/td><td class=\"oth\">113<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Phenylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90-43-7\/2-Phenylphenol\" target=\"_blank\" rel=\"noopener\">2-Phenylphenol<\/a><\/td><td class=\"oth\">4.31<\/td><td class=\"oth\">170.2<\/td><td class=\"oth\">141.2<\/td><td class=\"oth\">22<\/td><td class=\"oth\">141<\/td><td class=\"oth\">115.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/608-93-5\/Pentachlorobenzene\" target=\"_blank\" rel=\"noopener\">Pentachlorobenzene<\/a><\/td><td class=\"oth\">4.33<\/td><td class=\"oth\">250<\/td><td class=\"oth\">142<\/td><td class=\"oth\">30<\/td><td class=\"oth\">250<\/td><td class=\"oth\">179<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propachlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1918-16-7\/Propachlor\" target=\"_blank\" rel=\"noopener\">Propachlor<\/a><\/td><td class=\"oth\">4.60<\/td><td class=\"oth\">176<\/td><td class=\"oth\">57<\/td><td class=\"oth\">8<\/td><td class=\"oth\">120<\/td><td class=\"oth\">77<\/td><td class=\"oth\">19<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tecnazene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/117-18-0\/Tecnazene\" target=\"_blank\" rel=\"noopener\">Tecnazene<\/a><\/td><td class=\"oth\">4.60<\/td><td class=\"oth\">260.9<\/td><td class=\"oth\">202.9<\/td><td class=\"oth\">13<\/td><td class=\"oth\">214.9<\/td><td class=\"oth\">178.9<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diphenylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/122-39-4\/Diphenylamine\" target=\"_blank\" rel=\"noopener\">Diphenylamine<\/a><\/td><td class=\"oth\">4.63<\/td><td class=\"oth\">169.1<\/td><td class=\"oth\">167.1<\/td><td class=\"oth\">25<\/td><td class=\"oth\">169.1<\/td><td class=\"oth\">168.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cycloate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1134-23-2\/Cycloate\" target=\"_blank\" rel=\"noopener\">Cycloate<\/a><\/td><td class=\"oth\">4.67<\/td><td class=\"oth\">215<\/td><td class=\"oth\">154<\/td><td class=\"oth\">6<\/td><td class=\"oth\">154<\/td><td class=\"oth\">83<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,3,5,6-Tetrachloroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3481-20-7\/2,3,5,6-Tetrachloroaniline\" target=\"_blank\" rel=\"noopener\">2,3,5,6-Tetrachloroaniline<\/a><\/td><td class=\"oth\">4.69<\/td><td class=\"oth\">231<\/td><td class=\"oth\">122<\/td><td class=\"oth\">30<\/td><td class=\"oth\">231<\/td><td class=\"oth\">160<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorpropham\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/101-21-3\/Chlorpropham\" target=\"_blank\" rel=\"noopener\">Chlorpropham<\/a><\/td><td class=\"oth\">4.70<\/td><td class=\"oth\">213.1<\/td><td class=\"oth\">171.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">171<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethalfluralin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/55283-68-6\/Ethalfluralin\" target=\"_blank\" rel=\"noopener\">Ethalfluralin<\/a><\/td><td class=\"oth\">4.75<\/td><td class=\"oth\">316.1<\/td><td class=\"oth\">276.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">276.1<\/td><td class=\"oth\">202.1<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Trifluralin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1582-09-8\/Trifluralin\" target=\"_blank\" rel=\"noopener\">Trifluralin<\/a><\/td><td class=\"oth\">4.78<\/td><td class=\"oth\">306.1<\/td><td class=\"oth\">206.2<\/td><td class=\"oth\">12<\/td><td class=\"oth\">306.1<\/td><td class=\"oth\">264.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benfluralin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1861-40-1\/Benfluralin\" target=\"_blank\" rel=\"noopener\">Benfluralin<\/a><\/td><td class=\"oth\">4.80<\/td><td class=\"oth\">292<\/td><td class=\"oth\">160.1<\/td><td class=\"oth\">20<\/td><td class=\"oth\">292<\/td><td class=\"oth\">264.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Sulfotepp\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3689-24-5\/Sulfotepp\" target=\"_blank\" rel=\"noopener\">Sulfotepp<\/a><\/td><td class=\"oth\">4.85<\/td><td class=\"oth\">322<\/td><td class=\"oth\">146<\/td><td class=\"oth\">23<\/td><td class=\"oth\">202<\/td><td class=\"oth\">146<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diallate 1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2303-16-4\/Diallate 1\" target=\"_blank\" rel=\"noopener\">Diallate 1<\/a><\/td><td class=\"oth\">4.89<\/td><td class=\"oth\">234.1<\/td><td class=\"oth\">150<\/td><td class=\"oth\">18<\/td><td class=\"oth\">234.1<\/td><td class=\"oth\">192.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phorate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-02-2\/Phorate\" target=\"_blank\" rel=\"noopener\">Phorate<\/a><\/td><td class=\"oth\">4.90<\/td><td class=\"oth\">260.1<\/td><td class=\"oth\">75<\/td><td class=\"oth\">8<\/td><td class=\"oth\">121.1<\/td><td class=\"oth\">65<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diallate 2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2303-16-4\/Diallate 2\" target=\"_blank\" rel=\"noopener\">Diallate 2<\/a><\/td><td class=\"oth\">4.95<\/td><td class=\"oth\">234.1<\/td><td class=\"oth\">150<\/td><td class=\"oth\">18<\/td><td class=\"oth\">234.1<\/td><td class=\"oth\">192.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-BHC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/319-84-6\/\u03b1-BHC\" target=\"_blank\" rel=\"noopener\">\u03b1-BHC<\/a><\/td><td class=\"oth\">5.00<\/td><td class=\"oth\">219<\/td><td class=\"oth\">183<\/td><td class=\"oth\">8<\/td><td class=\"oth\">181<\/td><td class=\"oth\">145<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/118-74-1\/Hexachlorobenzene\" target=\"_blank\" rel=\"noopener\">Hexachlorobenzene<\/a><\/td><td class=\"oth\">5.02<\/td><td class=\"oth\">283.8<\/td><td class=\"oth\">213.9<\/td><td class=\"oth\">30<\/td><td class=\"oth\">248.9<\/td><td class=\"oth\">213.9<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">29.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dicloran\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-30-9\/Dicloran\" target=\"_blank\" rel=\"noopener\">Dicloran<\/a><\/td><td class=\"oth\">5.03<\/td><td class=\"oth\">206<\/td><td class=\"oth\">147.9<\/td><td class=\"oth\">18<\/td><td class=\"oth\">176<\/td><td class=\"oth\">148<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">30.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachloroanisole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1825-21-4\/Pentachloroanisole\" target=\"_blank\" rel=\"noopener\">Pentachloroanisole<\/a><\/td><td class=\"oth\">5.04<\/td><td class=\"oth\">279.9<\/td><td class=\"oth\">236.9<\/td><td class=\"oth\">23<\/td><td class=\"oth\">266.9<\/td><td class=\"oth\">238.9<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">31.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Atrazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1912-24-9\/Atrazine\" target=\"_blank\" rel=\"noopener\">Atrazine<\/a><\/td><td class=\"oth\">5.05<\/td><td class=\"oth\">215<\/td><td class=\"oth\">173.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">200.1<\/td><td class=\"oth\">122.1<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">32.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Clomazone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/81777-89-1\/Clomazone\" target=\"_blank\" rel=\"noopener\">Clomazone<\/a><\/td><td class=\"oth\">5.10<\/td><td class=\"oth\">204<\/td><td class=\"oth\">107<\/td><td class=\"oth\">18<\/td><td class=\"oth\">125<\/td><td class=\"oth\">89<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">33.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b2-BHC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/319-85-7\/\u03b2-BHC\" target=\"_blank\" rel=\"noopener\">\u03b2-BHC<\/a><\/td><td class=\"oth\">5.12<\/td><td class=\"oth\">219<\/td><td class=\"oth\">183<\/td><td class=\"oth\">8<\/td><td class=\"oth\">181<\/td><td class=\"oth\">145<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">34.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Profluralin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/26399-36-0\/Profluralin\" target=\"_blank\" rel=\"noopener\">Profluralin<\/a><\/td><td class=\"oth\">5.14<\/td><td class=\"oth\">330.1<\/td><td class=\"oth\">69<\/td><td class=\"oth\">25<\/td><td class=\"oth\">318.1<\/td><td class=\"oth\">199<\/td><td class=\"oth\">17<\/td><\/tr>\n<tr><td class=\"num\">35.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Terbuthylazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5915-41-3\/Terbuthylazine\" target=\"_blank\" rel=\"noopener\">Terbuthylazine<\/a><\/td><td class=\"oth\">5.16<\/td><td class=\"oth\">229.1<\/td><td class=\"oth\">173.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">172.8<\/td><td class=\"oth\">137.9<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">36.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Terbufos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13071-79-9\/Terbufos\" target=\"_blank\" rel=\"noopener\">Terbufos<\/a><\/td><td class=\"oth\">5.17<\/td><td class=\"oth\">231<\/td><td class=\"oth\">129<\/td><td class=\"oth\">23<\/td><td class=\"oth\">231<\/td><td class=\"oth\">175<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">37.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b3-BHC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/58-89-9\/\u03b3-BHC\" target=\"_blank\" rel=\"noopener\">\u03b3-BHC<\/a><\/td><td class=\"oth\">5.16<\/td><td class=\"oth\">219<\/td><td class=\"oth\">183<\/td><td class=\"oth\">8<\/td><td class=\"oth\">181<\/td><td class=\"oth\">145<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">38.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propyzamide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/23950-58-5\/Propyzamide\" target=\"_blank\" rel=\"noopener\">Propyzamide<\/a><\/td><td class=\"oth\">5.18<\/td><td class=\"oth\">173<\/td><td class=\"oth\">109<\/td><td class=\"oth\">27<\/td><td class=\"oth\">173<\/td><td class=\"oth\">145<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">39.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diazinon\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/333-41-5\/Diazinon\" target=\"_blank\" rel=\"noopener\">Diazinon<\/a><\/td><td class=\"oth\">5.19<\/td><td class=\"oth\">304<\/td><td class=\"oth\">179.1<\/td><td class=\"oth\">12<\/td><td class=\"oth\">137.1<\/td><td class=\"oth\">84.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">40.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fonofos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/944-22-9\/Fonofos\" target=\"_blank\" rel=\"noopener\">Fonofos<\/a><\/td><td class=\"oth\">5.19<\/td><td class=\"oth\">246.1<\/td><td class=\"oth\">137.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">137.1<\/td><td class=\"oth\">109<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">41.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Quintozene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/82-68-8\/Quintozene\" target=\"_blank\" rel=\"noopener\">Quintozene<\/a><\/td><td class=\"oth\">5.19<\/td><td class=\"oth\">294.8<\/td><td class=\"oth\">237<\/td><td class=\"oth\">15<\/td><td class=\"oth\">236.8<\/td><td class=\"oth\">119<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">42.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluchloralin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/33245-39-5\/Fluchloralin\" target=\"_blank\" rel=\"noopener\">Fluchloralin<\/a><\/td><td class=\"oth\">5.21<\/td><td class=\"oth\">306.1<\/td><td class=\"oth\">159.7<\/td><td class=\"oth\">20<\/td><td class=\"oth\">306.1<\/td><td class=\"oth\">264<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">43.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachlorobenzonitrile\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/20925-85-3\/Pentachlorobenzonitrile\" target=\"_blank\" rel=\"noopener\">Pentachlorobenzonitrile<\/a><\/td><td class=\"oth\">5.21<\/td><td class=\"oth\">275<\/td><td class=\"oth\">205<\/td><td class=\"oth\">30<\/td><td class=\"oth\">273<\/td><td class=\"oth\">238<\/td><td class=\"oth\">17<\/td><\/tr>\n<tr><td class=\"num\">44.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyrimethanil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53112-28-0\/Pyrimethanil\" target=\"_blank\" rel=\"noopener\">Pyrimethanil<\/a><\/td><td class=\"oth\">5.21<\/td><td class=\"oth\">198.1<\/td><td class=\"oth\">118.1<\/td><td class=\"oth\">32<\/td><td class=\"oth\">198.1<\/td><td class=\"oth\">183<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">45.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tefluthrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/79538-32-2\/Tefluthrin\" target=\"_blank\" rel=\"noopener\">Tefluthrin<\/a><\/td><td class=\"oth\">5.24<\/td><td class=\"oth\">177<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">15<\/td><td class=\"oth\">177<\/td><td class=\"oth\">137.1<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">46.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Disulfoton\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-04-4\/Disulfoton\" target=\"_blank\" rel=\"noopener\">Disulfoton<\/a><\/td><td class=\"oth\">5.25<\/td><td class=\"oth\">153.1<\/td><td class=\"oth\">97<\/td><td class=\"oth\">12<\/td><td class=\"oth\">88.1<\/td><td class=\"oth\">59.9<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">47.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Terbacil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5902-51-2\/Terbacil\" target=\"_blank\" rel=\"noopener\">Terbacil<\/a><\/td><td class=\"oth\">5.26<\/td><td class=\"oth\">161<\/td><td class=\"oth\">144<\/td><td class=\"oth\">14<\/td><td class=\"oth\">160<\/td><td class=\"oth\">117<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">48.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isazophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/42509-80-8\/Isazophos\" target=\"_blank\" rel=\"noopener\">Isazophos<\/a><\/td><td class=\"oth\">5.29<\/td><td class=\"oth\">172.1<\/td><td class=\"oth\">130<\/td><td class=\"oth\">10<\/td><td class=\"oth\">161.1<\/td><td class=\"oth\">119<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">49.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b4-BHC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/319-86-8\/\u03b4-BHC\" target=\"_blank\" rel=\"noopener\">\u03b4-BHC<\/a><\/td><td class=\"oth\">5.31<\/td><td class=\"oth\">219<\/td><td class=\"oth\">183<\/td><td class=\"oth\">8<\/td><td class=\"oth\">181<\/td><td class=\"oth\">145<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">50.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Triallate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2303-17-5\/Triallate\" target=\"_blank\" rel=\"noopener\">Triallate<\/a><\/td><td class=\"oth\">5.32<\/td><td class=\"oth\">270<\/td><td class=\"oth\">186<\/td><td class=\"oth\">18<\/td><td class=\"oth\">268<\/td><td class=\"oth\">184<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">51.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorothalonil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1897-45-6\/Chlorothalonil\" target=\"_blank\" rel=\"noopener\">Chlorothalonil<\/a><\/td><td class=\"oth\">5.34<\/td><td class=\"oth\">266<\/td><td class=\"oth\">170<\/td><td class=\"oth\">23<\/td><td class=\"oth\">264<\/td><td class=\"oth\">168<\/td><td class=\"oth\">23<\/td><\/tr>\n<tr><td class=\"num\">52.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Anthracene (IS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-12-7\/Anthracene\" target=\"_blank\" rel=\"noopener\">Anthracene (IS)<\/a><\/td><td class=\"oth\">5.35<\/td><td class=\"oth\">178<\/td><td class=\"oth\">152<\/td><td class=\"oth\">20<\/td><td class=\"oth\"><\/td><td class=\"oth\"><\/td><td class=\"oth\"><\/td><\/tr>\n<tr><td class=\"num\">53.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Endosulfan ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3369-52-6\/Endosulfan ether\" target=\"_blank\" rel=\"noopener\">Endosulfan ether<\/a><\/td><td class=\"oth\">5.42<\/td><td class=\"oth\">240.9<\/td><td class=\"oth\">206<\/td><td class=\"oth\">13<\/td><td class=\"oth\">238.9<\/td><td class=\"oth\">204<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">54.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propanil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/709-98-8\/Propanil\" target=\"_blank\" rel=\"noopener\">Propanil<\/a><\/td><td class=\"oth\">5.44<\/td><td class=\"oth\">219<\/td><td class=\"oth\">163<\/td><td class=\"oth\">8<\/td><td class=\"oth\">217<\/td><td class=\"oth\">161<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">55.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachloroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/527-20-8\/Pentachloroaniline\" target=\"_blank\" rel=\"noopener\">Pentachloroaniline<\/a><\/td><td class=\"oth\">5.45<\/td><td class=\"oth\">265<\/td><td class=\"oth\">194<\/td><td class=\"oth\">22<\/td><td class=\"oth\">263<\/td><td class=\"oth\">192<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">56.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dimethachlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50563-36-5\/Dimethachlor\" target=\"_blank\" rel=\"noopener\">Dimethachlor<\/a><\/td><td class=\"oth\">5.46<\/td><td class=\"oth\">197<\/td><td class=\"oth\">148<\/td><td class=\"oth\">8<\/td><td class=\"oth\">134<\/td><td class=\"oth\">105<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">57.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetochlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/34256-82-1\/Acetochlor\" target=\"_blank\" rel=\"noopener\">Acetochlor<\/a><\/td><td class=\"oth\">5.48<\/td><td class=\"oth\">223<\/td><td class=\"oth\">132<\/td><td class=\"oth\">20<\/td><td class=\"oth\">174<\/td><td class=\"oth\">146<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">58.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Transfluthrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/118712-89-3\/Transfluthrin\" target=\"_blank\" rel=\"noopener\">Transfluthrin<\/a><\/td><td class=\"oth\">5.48<\/td><td class=\"oth\">163<\/td><td class=\"oth\">143<\/td><td class=\"oth\">13<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">91.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">59.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Vinclozolin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50471-44-8\/Vinclozolin\" target=\"_blank\" rel=\"noopener\">Vinclozolin<\/a><\/td><td class=\"oth\">5.50<\/td><td class=\"oth\">285<\/td><td class=\"oth\">212<\/td><td class=\"oth\">12<\/td><td class=\"oth\">212<\/td><td class=\"oth\">172<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">60.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorpyrifos methyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5598-13-0\/Chlorpyrifos methyl\" target=\"_blank\" rel=\"noopener\">Chlorpyrifos methyl<\/a><\/td><td class=\"oth\">5.52<\/td><td class=\"oth\">286<\/td><td class=\"oth\">93<\/td><td class=\"oth\">22<\/td><td class=\"oth\">286<\/td><td class=\"oth\">207.9<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">61.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl parathion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-00-0\/Methyl parathion\" target=\"_blank\" rel=\"noopener\">Methyl parathion<\/a><\/td><td class=\"oth\">5.52<\/td><td class=\"oth\">263<\/td><td class=\"oth\">109<\/td><td class=\"oth\">10<\/td><td class=\"oth\">263<\/td><td class=\"oth\">136.2<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">62.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tolclofos-methyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57018-04-9\/Tolclofos-methyl\" target=\"_blank\" rel=\"noopener\">Tolclofos-methyl<\/a><\/td><td class=\"oth\">5.54<\/td><td class=\"oth\">267<\/td><td class=\"oth\">252<\/td><td class=\"oth\">10<\/td><td class=\"oth\">265<\/td><td class=\"oth\">250<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">63.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Alachlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/15972-60-8\/Alachlor\" target=\"_blank\" rel=\"noopener\">Alachlor<\/a><\/td><td class=\"oth\">5.55<\/td><td class=\"oth\">188<\/td><td class=\"oth\">160<\/td><td class=\"oth\">10<\/td><td class=\"oth\">146<\/td><td class=\"oth\">118<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">64.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Metalaxyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57837-19-1\/Metalaxyl\" target=\"_blank\" rel=\"noopener\">Metalaxyl<\/a><\/td><td class=\"oth\">5.56<\/td><td class=\"oth\">220.1<\/td><td class=\"oth\">160.2<\/td><td class=\"oth\">10<\/td><td class=\"oth\">160.1<\/td><td class=\"oth\">145.1<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">65.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propisochlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/86763-47-5\/Propisochlor\" target=\"_blank\" rel=\"noopener\">Propisochlor<\/a><\/td><td class=\"oth\">5.56<\/td><td class=\"oth\">223<\/td><td class=\"oth\">132<\/td><td class=\"oth\">18<\/td><td class=\"oth\">162<\/td><td class=\"oth\">120<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">66.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenchlorphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/299-84-3\/Fenchlorphos\" target=\"_blank\" rel=\"noopener\">Fenchlorphos<\/a><\/td><td class=\"oth\">5.59<\/td><td class=\"oth\">287<\/td><td class=\"oth\">272<\/td><td class=\"oth\">11<\/td><td class=\"oth\">285<\/td><td class=\"oth\">240<\/td><td class=\"oth\">23<\/td><\/tr>\n<tr><td class=\"num\">67.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Heptachlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-44-8\/Heptachlor\" target=\"_blank\" rel=\"noopener\">Heptachlor<\/a><\/td><td class=\"oth\">5.59<\/td><td class=\"oth\">272<\/td><td class=\"oth\">237<\/td><td class=\"oth\">13<\/td><td class=\"oth\">100<\/td><td class=\"oth\">65<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">68.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Prodiamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/29091-21-2\/Prodiamine\" target=\"_blank\" rel=\"noopener\">Prodiamine<\/a><\/td><td class=\"oth\">5.63<\/td><td class=\"oth\">321<\/td><td class=\"oth\">279<\/td><td class=\"oth\">6<\/td><td class=\"oth\">279<\/td><td class=\"oth\">203<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">69.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pirimiphos methyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/29232-93-7\/Pirimiphos methyl\" target=\"_blank\" rel=\"noopener\">Pirimiphos methyl<\/a><\/td><td class=\"oth\">5.65<\/td><td class=\"oth\">305.1<\/td><td class=\"oth\">180.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">290.1<\/td><td class=\"oth\">125<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">70.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenitrothion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/122-14-5\/Fenitrothion\" target=\"_blank\" rel=\"noopener\">Fenitrothion<\/a><\/td><td class=\"oth\">5.66<\/td><td class=\"oth\">277<\/td><td class=\"oth\">109<\/td><td class=\"oth\">16<\/td><td class=\"oth\">260<\/td><td class=\"oth\">125<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">71.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Linuron\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/330-55-2\/Linuron\" target=\"_blank\" rel=\"noopener\">Linuron<\/a><\/td><td class=\"oth\">5.69<\/td><td class=\"oth\">248<\/td><td class=\"oth\">61<\/td><td class=\"oth\">8<\/td><td class=\"oth\">187<\/td><td class=\"oth\">124<\/td><td class=\"oth\">21<\/td><\/tr>\n<tr><td class=\"num\">72.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Malathion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/121-75-5\/Malathion\" target=\"_blank\" rel=\"noopener\">Malathion<\/a><\/td><td class=\"oth\">5.69<\/td><td class=\"oth\">173<\/td><td class=\"oth\">99<\/td><td class=\"oth\">13<\/td><td class=\"oth\">127<\/td><td class=\"oth\">99<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">73.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dichlofluanid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1085-98-9\/Dichlofluanid\" target=\"_blank\" rel=\"noopener\">Dichlofluanid<\/a><\/td><td class=\"oth\">5.72<\/td><td class=\"oth\">224<\/td><td class=\"oth\">123<\/td><td class=\"oth\">12<\/td><td class=\"oth\">123<\/td><td class=\"oth\">77.1<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">74.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachlorothioanisole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1825-19-0\/Pentachlorothioanisole\" target=\"_blank\" rel=\"noopener\">Pentachlorothioanisole<\/a><\/td><td class=\"oth\">5.73<\/td><td class=\"oth\">296<\/td><td class=\"oth\">246<\/td><td class=\"oth\">32<\/td><td class=\"oth\">296<\/td><td class=\"oth\">263<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">75.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Metolachlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51218-45-2\/Metolachlor\" target=\"_blank\" rel=\"noopener\">Metolachlor<\/a><\/td><td class=\"oth\">5.76<\/td><td class=\"oth\">238<\/td><td class=\"oth\">162<\/td><td class=\"oth\">10<\/td><td class=\"oth\">162<\/td><td class=\"oth\">133<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">76.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorpyrifos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2921-88-2\/Chlorpyrifos\" target=\"_blank\" rel=\"noopener\">Chlorpyrifos<\/a><\/td><td class=\"oth\">5.77<\/td><td class=\"oth\">314<\/td><td class=\"oth\">257.9<\/td><td class=\"oth\">12<\/td><td class=\"oth\">196.9<\/td><td class=\"oth\">168.9<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">77.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenthion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/55-38-9\/Fenthion\" target=\"_blank\" rel=\"noopener\">Fenthion<\/a><\/td><td class=\"oth\">5.77<\/td><td class=\"oth\">278<\/td><td class=\"oth\">109<\/td><td class=\"oth\">18<\/td><td class=\"oth\">278<\/td><td class=\"oth\">169<\/td><td class=\"oth\">17<\/td><\/tr>\n<tr><td class=\"num\">78.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Parathion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-38-2\/Parathion\" target=\"_blank\" rel=\"noopener\">Parathion<\/a><\/td><td class=\"oth\">5.78<\/td><td class=\"oth\">291.2<\/td><td class=\"oth\">109.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">109<\/td><td class=\"oth\">81<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">79.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Anthraquinone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/84-65-1\/Anthraquinone\" target=\"_blank\" rel=\"noopener\">Anthraquinone<\/a><\/td><td class=\"oth\">5.79<\/td><td class=\"oth\">208.1<\/td><td class=\"oth\">180.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">180.1<\/td><td class=\"oth\">152.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">80.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Triadimefon\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/43121-43-3\/Triadimefon\" target=\"_blank\" rel=\"noopener\">Triadimefon<\/a><\/td><td class=\"oth\">5.79<\/td><td class=\"oth\">208<\/td><td class=\"oth\">110.9<\/td><td class=\"oth\">24<\/td><td class=\"oth\">208<\/td><td class=\"oth\">180.8<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">81.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aldrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/309-00-2\/Aldrin\" target=\"_blank\" rel=\"noopener\">Aldrin<\/a><\/td><td class=\"oth\">5.80<\/td><td class=\"oth\">298<\/td><td class=\"oth\">263<\/td><td class=\"oth\">8<\/td><td class=\"oth\">263<\/td><td class=\"oth\">193<\/td><td class=\"oth\">31<\/td><\/tr>\n<tr><td class=\"num\">82.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorthal-dimethyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1861-32-1\/Chlorthal-dimethyl\" target=\"_blank\" rel=\"noopener\">Chlorthal-dimethyl<\/a><\/td><td class=\"oth\">5.81<\/td><td class=\"oth\">331.8<\/td><td class=\"oth\">301<\/td><td class=\"oth\">8<\/td><td class=\"oth\">298.9<\/td><td class=\"oth\">220.9<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">83.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4,4&amp;apos;-Dichlorobenzophenone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90-98-2\/4,4&amp;apos;-Dichlorobenzophenone\" target=\"_blank\" rel=\"noopener\">4,4&#8242;-Dichlorobenzophenone<\/a><\/td><td class=\"oth\">5.81<\/td><td class=\"oth\">139<\/td><td class=\"oth\">75<\/td><td class=\"oth\">27<\/td><td class=\"oth\">111<\/td><td class=\"oth\">75.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">84.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pirimiphos ethyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/23505-41-1\/Pirimiphos ethyl\" target=\"_blank\" rel=\"noopener\">Pirimiphos ethyl<\/a><\/td><td class=\"oth\">5.85<\/td><td class=\"oth\">318.2<\/td><td class=\"oth\">166.1<\/td><td class=\"oth\">12<\/td><td class=\"oth\">304.1<\/td><td class=\"oth\">168.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">85.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenson\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/80-38-6\/Fenson\" target=\"_blank\" rel=\"noopener\">Fenson<\/a><\/td><td class=\"oth\">5.86<\/td><td class=\"oth\">268<\/td><td class=\"oth\">77.1<\/td><td class=\"oth\">18<\/td><td class=\"oth\">141<\/td><td class=\"oth\">77.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">86.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cyprodinil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/121552-61-2\/Cyprodinil\" target=\"_blank\" rel=\"noopener\">Cyprodinil<\/a><\/td><td class=\"oth\">5.87<\/td><td class=\"oth\">225.2<\/td><td class=\"oth\">209.8<\/td><td class=\"oth\">12<\/td><td class=\"oth\">224.1<\/td><td class=\"oth\">208.1<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">87.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diphenamid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/957-51-7\/Diphenamid\" target=\"_blank\" rel=\"noopener\">Diphenamid<\/a><\/td><td class=\"oth\">5.88<\/td><td class=\"oth\">239<\/td><td class=\"oth\">167<\/td><td class=\"oth\">8<\/td><td class=\"oth\">167<\/td><td class=\"oth\">115<\/td><td class=\"oth\">40<\/td><\/tr>\n<tr><td class=\"num\">88.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isopropalin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/33820-53-0\/Isopropalin\" target=\"_blank\" rel=\"noopener\">Isopropalin<\/a><\/td><td class=\"oth\">5.89<\/td><td class=\"oth\">280.1<\/td><td class=\"oth\">118.1<\/td><td class=\"oth\">25<\/td><td class=\"oth\">280.1<\/td><td class=\"oth\">238.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">89.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for MGK 264 1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/113-48-4\/MGK 264 1\" target=\"_blank\" rel=\"noopener\">MGK 264 1<\/a><\/td><td class=\"oth\">5.89<\/td><td class=\"oth\">164.1<\/td><td class=\"oth\">80<\/td><td class=\"oth\">24<\/td><td class=\"oth\">164.1<\/td><td class=\"oth\">93.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">90.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bromophos-methyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2104-96-3\/Bromophos-methyl\" target=\"_blank\" rel=\"noopener\">Bromophos-methyl<\/a><\/td><td class=\"oth\">5.90<\/td><td class=\"oth\">331<\/td><td class=\"oth\">316<\/td><td class=\"oth\">13<\/td><td class=\"oth\">329<\/td><td class=\"oth\">314<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">91.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlozolinate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/84332-86-5\/Chlozolinate\" target=\"_blank\" rel=\"noopener\">Chlozolinate<\/a><\/td><td class=\"oth\">5.95<\/td><td class=\"oth\">331<\/td><td class=\"oth\">259.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">186<\/td><td class=\"oth\">145<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">92.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pendimethalin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/40487-42-1\/Pendimethalin\" target=\"_blank\" rel=\"noopener\">Pendimethalin<\/a><\/td><td class=\"oth\">5.95<\/td><td class=\"oth\">281.1<\/td><td class=\"oth\">252.2<\/td><td class=\"oth\">8<\/td><td class=\"oth\">252.1<\/td><td class=\"oth\">162.1<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">93.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bioallethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/584-79-2\/Bioallethrin\" target=\"_blank\" rel=\"noopener\">Bioallethrin<\/a><\/td><td class=\"oth\">5.96<\/td><td class=\"oth\">136.1<\/td><td class=\"oth\">93<\/td><td class=\"oth\">11<\/td><td class=\"oth\">123.2<\/td><td class=\"oth\">81.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">94.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fipronil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120068-37-3\/Fipronil\" target=\"_blank\" rel=\"noopener\">Fipronil<\/a><\/td><td class=\"oth\">5.97<\/td><td class=\"oth\">367<\/td><td class=\"oth\">213<\/td><td class=\"oth\">30<\/td><td class=\"oth\">369<\/td><td class=\"oth\">215<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">95.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for MGK 264 2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/113-48-4\/MGK 264 2\" target=\"_blank\" rel=\"noopener\">MGK 264 2<\/a><\/td><td class=\"oth\">5.97<\/td><td class=\"oth\">164<\/td><td class=\"oth\">67<\/td><td class=\"oth\">10<\/td><td class=\"oth\">164.1<\/td><td class=\"oth\">80<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">96.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isodrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/465-73-6\/Isodrin\" target=\"_blank\" rel=\"noopener\">Isodrin<\/a><\/td><td class=\"oth\">5.97<\/td><td class=\"oth\">260.9<\/td><td class=\"oth\">190.9<\/td><td class=\"oth\">28<\/td><td class=\"oth\">193<\/td><td class=\"oth\">123<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">97.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Metazachlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/67129-08-2\/Metazachlor\" target=\"_blank\" rel=\"noopener\">Metazachlor<\/a><\/td><td class=\"oth\">5.97<\/td><td class=\"oth\">209<\/td><td class=\"oth\">132<\/td><td class=\"oth\">15<\/td><td class=\"oth\">133<\/td><td class=\"oth\">117<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">98.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Penconazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/66246-88-6\/Penconazole\" target=\"_blank\" rel=\"noopener\">Penconazole<\/a><\/td><td class=\"oth\">5.97<\/td><td class=\"oth\">248.1<\/td><td class=\"oth\">192<\/td><td class=\"oth\">16<\/td><td class=\"oth\">159<\/td><td class=\"oth\">89<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">99.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorfenvinphos 1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/470-90-6\/Chlorfenvinphos 1\" target=\"_blank\" rel=\"noopener\">Chlorfenvinphos 1<\/a><\/td><td class=\"oth\">6.04<\/td><td class=\"oth\">323<\/td><td class=\"oth\">267<\/td><td class=\"oth\">10<\/td><td class=\"oth\">267<\/td><td class=\"oth\">159<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">100.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tolylfluanid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/731-27-1\/Tolylfluanid\" target=\"_blank\" rel=\"noopener\">Tolylfluanid<\/a><\/td><td class=\"oth\">6.05<\/td><td class=\"oth\">240<\/td><td class=\"oth\">137<\/td><td class=\"oth\">10<\/td><td class=\"oth\">238<\/td><td class=\"oth\">137<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">101.<\/td><td class=\"cmpd\">Bromfenvinphos-methyl<\/td><td class=\"oth\">6.06<\/td><td class=\"oth\">295<\/td><td class=\"oth\">109<\/td><td class=\"oth\">15<\/td><td class=\"oth\">109<\/td><td class=\"oth\">79<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">102.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Heptachlor epoxide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1024-57-3\/Heptachlor epoxide\" target=\"_blank\" rel=\"noopener\">Heptachlor epoxide<\/a><\/td><td class=\"oth\">6.07<\/td><td class=\"oth\">353<\/td><td class=\"oth\">263<\/td><td class=\"oth\">13<\/td><td class=\"oth\">263<\/td><td class=\"oth\">193<\/td><td class=\"oth\">29<\/td><\/tr>\n<tr><td class=\"num\">103.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Quinalphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13593-03-8\/Quinalphos\" target=\"_blank\" rel=\"noopener\">Quinalphos<\/a><\/td><td class=\"oth\">6.07<\/td><td class=\"oth\">298<\/td><td class=\"oth\">156.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">146.1<\/td><td class=\"oth\">118.1<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">104.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Triadimenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/55219-65-3\/Triadimenol\" target=\"_blank\" rel=\"noopener\">Triadimenol<\/a><\/td><td class=\"oth\">6.07<\/td><td class=\"oth\">168.1<\/td><td class=\"oth\">70.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">128<\/td><td class=\"oth\">65.1<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">105.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Triflumizole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/68694-11-1\/Triflumizole\" target=\"_blank\" rel=\"noopener\">Triflumizole<\/a><\/td><td class=\"oth\">6.09<\/td><td class=\"oth\">205.9<\/td><td class=\"oth\">179<\/td><td class=\"oth\">14<\/td><td class=\"oth\">179<\/td><td class=\"oth\">143.8<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">106.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Captan\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/133-06-2\/Captan\" target=\"_blank\" rel=\"noopener\">Captan<\/a><\/td><td class=\"oth\">6.10<\/td><td class=\"oth\">149<\/td><td class=\"oth\">105<\/td><td class=\"oth\">6<\/td><td class=\"oth\">106.8<\/td><td class=\"oth\">79<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">107.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Procymidone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/32809-16-8\/Procymidone\" target=\"_blank\" rel=\"noopener\">Procymidone<\/a><\/td><td class=\"oth\">6.11<\/td><td class=\"oth\">283<\/td><td class=\"oth\">67.1<\/td><td class=\"oth\">28<\/td><td class=\"oth\">283<\/td><td class=\"oth\">96<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">108.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Folpet\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/133-07-3\/Folpet\" target=\"_blank\" rel=\"noopener\">Folpet<\/a><\/td><td class=\"oth\">6.14<\/td><td class=\"oth\">259.9<\/td><td class=\"oth\">130<\/td><td class=\"oth\">16<\/td><td class=\"oth\">103.9<\/td><td class=\"oth\">76<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">109.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorbenside\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/103-17-3\/Chlorbenside\" target=\"_blank\" rel=\"noopener\">Chlorbenside<\/a><\/td><td class=\"oth\">6.15<\/td><td class=\"oth\">268<\/td><td class=\"oth\">125.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">125<\/td><td class=\"oth\">89.1<\/td><td class=\"oth\">17<\/td><\/tr>\n<tr><td class=\"num\">110.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bromophos-ethyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/4824-78-6\/Bromophos-ethyl\" target=\"_blank\" rel=\"noopener\">Bromophos-ethyl<\/a><\/td><td class=\"oth\">6.17<\/td><td class=\"oth\">358.9<\/td><td class=\"oth\">303<\/td><td class=\"oth\">17<\/td><td class=\"oth\">330.9<\/td><td class=\"oth\">303<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">111.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for trans-Chlordane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5103-74-2\/trans-Chlordane\" target=\"_blank\" rel=\"noopener\">trans-Chlordane<\/a><\/td><td class=\"oth\">6.19<\/td><td class=\"oth\">375<\/td><td class=\"oth\">266<\/td><td class=\"oth\">18<\/td><td class=\"oth\">272<\/td><td class=\"oth\">237<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">112.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Paclobutrazol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76738-62-0\/Paclobutrazol\" target=\"_blank\" rel=\"noopener\">Paclobutrazol<\/a><\/td><td class=\"oth\">6.19<\/td><td class=\"oth\">237.8<\/td><td class=\"oth\">127<\/td><td class=\"oth\">10<\/td><td class=\"oth\">236.1<\/td><td class=\"oth\">125.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">113.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4&amp;apos;-DDE\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3424-82-6\/2,4&amp;apos;-DDE\" target=\"_blank\" rel=\"noopener\">2,4&#8242;-DDE<\/a><\/td><td class=\"oth\">6.19<\/td><td class=\"oth\">316<\/td><td class=\"oth\">246<\/td><td class=\"oth\">15<\/td><td class=\"oth\">246<\/td><td class=\"oth\">176<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">114.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tetrachlorvinphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/22248-79-9\/Tetrachlorvinphos\" target=\"_blank\" rel=\"noopener\">Tetrachlorvinphos<\/a><\/td><td class=\"oth\">6.20<\/td><td class=\"oth\">333<\/td><td class=\"oth\">109<\/td><td class=\"oth\">17<\/td><td class=\"oth\">331<\/td><td class=\"oth\">109<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">115.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenamiphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/22224-92-6\/Fenamiphos\" target=\"_blank\" rel=\"noopener\">Fenamiphos<\/a><\/td><td class=\"oth\">6.25<\/td><td class=\"oth\">303.1<\/td><td class=\"oth\">195.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">217<\/td><td class=\"oth\">202<\/td><td class=\"oth\">9<\/td><\/tr>\n<tr><td class=\"num\">116.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flutolanil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/66332-96-5\/Flutolanil\" target=\"_blank\" rel=\"noopener\">Flutolanil<\/a><\/td><td class=\"oth\">6.26<\/td><td class=\"oth\">281<\/td><td class=\"oth\">173<\/td><td class=\"oth\">10<\/td><td class=\"oth\">173<\/td><td class=\"oth\">145<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">117.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Prothiofos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/34643-46-4\/Prothiofos\" target=\"_blank\" rel=\"noopener\">Prothiofos<\/a><\/td><td class=\"oth\">6.26<\/td><td class=\"oth\">309<\/td><td class=\"oth\">239<\/td><td class=\"oth\">15<\/td><td class=\"oth\">267<\/td><td class=\"oth\">221<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">118.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for cis-Chlordane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5103-71-9\/cis-Chlordane\" target=\"_blank\" rel=\"noopener\">cis-Chlordane<\/a><\/td><td class=\"oth\">6.27<\/td><td class=\"oth\">375<\/td><td class=\"oth\">266<\/td><td class=\"oth\">18<\/td><td class=\"oth\">272<\/td><td class=\"oth\">237<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">119.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bromfenvinphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/33399-00-7\/Bromfenvinphos\" target=\"_blank\" rel=\"noopener\">Bromfenvinphos<\/a><\/td><td class=\"oth\">6.27<\/td><td class=\"oth\">325<\/td><td class=\"oth\">269<\/td><td class=\"oth\">10<\/td><td class=\"oth\">323<\/td><td class=\"oth\">267<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">120.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fludioxonil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/131341-86-1\/Fludioxonil\" target=\"_blank\" rel=\"noopener\">Fludioxonil<\/a><\/td><td class=\"oth\">6.27<\/td><td class=\"oth\">248<\/td><td class=\"oth\">127<\/td><td class=\"oth\">30<\/td><td class=\"oth\">153.8<\/td><td class=\"oth\">127<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">121.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flutriafol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76674-21-0\/Flutriafol\" target=\"_blank\" rel=\"noopener\">Flutriafol<\/a><\/td><td class=\"oth\">6.27<\/td><td class=\"oth\">219.1<\/td><td class=\"oth\">123<\/td><td class=\"oth\">14<\/td><td class=\"oth\">123.1<\/td><td class=\"oth\">95<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">122.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Iodofenphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/18181-70-9\/Iodofenphos\" target=\"_blank\" rel=\"noopener\">Iodofenphos<\/a><\/td><td class=\"oth\">6.27<\/td><td class=\"oth\">377<\/td><td class=\"oth\">332<\/td><td class=\"oth\">30<\/td><td class=\"oth\">377<\/td><td class=\"oth\">362<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">123.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pretilachlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51218-49-6\/Pretilachlor\" target=\"_blank\" rel=\"noopener\">Pretilachlor<\/a><\/td><td class=\"oth\">6.27<\/td><td class=\"oth\">262<\/td><td class=\"oth\">202<\/td><td class=\"oth\">8<\/td><td class=\"oth\">162<\/td><td class=\"oth\">132<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">124.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Profenofos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/41198-08-7\/Profenofos\" target=\"_blank\" rel=\"noopener\">Profenofos<\/a><\/td><td class=\"oth\">6.27<\/td><td class=\"oth\">339<\/td><td class=\"oth\">188<\/td><td class=\"oth\">30<\/td><td class=\"oth\">337<\/td><td class=\"oth\">267<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">125.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorfenvinphos 2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/470-90-6\/Chlorfenvinphos 2\" target=\"_blank\" rel=\"noopener\">Chlorfenvinphos 2<\/a><\/td><td class=\"oth\">6.27<\/td><td class=\"oth\">323<\/td><td class=\"oth\">267<\/td><td class=\"oth\">10<\/td><td class=\"oth\">267<\/td><td class=\"oth\">159<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">126.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Endosulfan I\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/959-98-8\/Endosulfan I\" target=\"_blank\" rel=\"noopener\">Endosulfan I<\/a><\/td><td class=\"oth\">6.28<\/td><td class=\"oth\">241<\/td><td class=\"oth\">206<\/td><td class=\"oth\">10<\/td><td class=\"oth\">195<\/td><td class=\"oth\">159<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">127.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for trans-Nonachlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/39765-80-5\/trans-Nonachlor\" target=\"_blank\" rel=\"noopener\">trans-Nonachlor<\/a><\/td><td class=\"oth\">6.28<\/td><td class=\"oth\">409<\/td><td class=\"oth\">263<\/td><td class=\"oth\">25<\/td><td class=\"oth\">409<\/td><td class=\"oth\">300<\/td><td class=\"oth\">23<\/td><\/tr>\n<tr><td class=\"num\">128.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorfenson\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/80-33-1\/Chlorfenson\" target=\"_blank\" rel=\"noopener\">Chlorfenson<\/a><\/td><td class=\"oth\">6.29<\/td><td class=\"oth\">302<\/td><td class=\"oth\">175<\/td><td class=\"oth\">8<\/td><td class=\"oth\">175<\/td><td class=\"oth\">111<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">129.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Oxadiazon\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/19666-30-9\/Oxadiazon\" target=\"_blank\" rel=\"noopener\">Oxadiazon<\/a><\/td><td class=\"oth\">6.33<\/td><td class=\"oth\">258<\/td><td class=\"oth\">175<\/td><td class=\"oth\">8<\/td><td class=\"oth\">175<\/td><td class=\"oth\">112<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">130.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Oxyfluorfen\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/42874-03-3\/Oxyfluorfen\" target=\"_blank\" rel=\"noopener\">Oxyfluorfen<\/a><\/td><td class=\"oth\">6.34<\/td><td class=\"oth\">300<\/td><td class=\"oth\">223<\/td><td class=\"oth\">15<\/td><td class=\"oth\">252.1<\/td><td class=\"oth\">146.1<\/td><td class=\"oth\">33<\/td><\/tr>\n<tr><td class=\"num\">131.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Myclobutanil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88671-89-0\/Myclobutanil\" target=\"_blank\" rel=\"noopener\">Myclobutanil<\/a><\/td><td class=\"oth\">6.38<\/td><td class=\"oth\">179<\/td><td class=\"oth\">125<\/td><td class=\"oth\">14<\/td><td class=\"oth\">179<\/td><td class=\"oth\">152<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">132.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bupirimate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/41483-43-6\/Bupirimate\" target=\"_blank\" rel=\"noopener\">Bupirimate<\/a><\/td><td class=\"oth\">6.39<\/td><td class=\"oth\">316.2<\/td><td class=\"oth\">208.2<\/td><td class=\"oth\">8<\/td><td class=\"oth\">273.1<\/td><td class=\"oth\">193.2<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">133.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flusilazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85509-19-9\/Flusilazole\" target=\"_blank\" rel=\"noopener\">Flusilazole<\/a><\/td><td class=\"oth\">6.39<\/td><td class=\"oth\">233.1<\/td><td class=\"oth\">164.9<\/td><td class=\"oth\">18<\/td><td class=\"oth\">206.1<\/td><td class=\"oth\">137<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">134.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4,4&amp;apos;-DDE\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72-55-9\/4,4&amp;apos;-DDE\" target=\"_blank\" rel=\"noopener\">4,4&#8242;-DDE<\/a><\/td><td class=\"oth\">6.40<\/td><td class=\"oth\">316<\/td><td class=\"oth\">246<\/td><td class=\"oth\">15<\/td><td class=\"oth\">246<\/td><td class=\"oth\">176<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">135.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tricyclazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/41814-78-2\/Tricyclazole\" target=\"_blank\" rel=\"noopener\">Tricyclazole<\/a><\/td><td class=\"oth\">6.41<\/td><td class=\"oth\">189<\/td><td class=\"oth\">135.2<\/td><td class=\"oth\">18<\/td><td class=\"oth\">189<\/td><td class=\"oth\">162<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">136.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4&amp;apos;-DDD\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53-19-0\/2,4&amp;apos;-DDD\" target=\"_blank\" rel=\"noopener\">2,4&#8242;-DDD<\/a><\/td><td class=\"oth\">6.42<\/td><td class=\"oth\">235<\/td><td class=\"oth\">165.1<\/td><td class=\"oth\">21<\/td><td class=\"oth\">235<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">137.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dieldrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60-57-1\/Dieldrin\" target=\"_blank\" rel=\"noopener\">Dieldrin<\/a><\/td><td class=\"oth\">6.42<\/td><td class=\"oth\">277<\/td><td class=\"oth\">241<\/td><td class=\"oth\">8<\/td><td class=\"oth\">263<\/td><td class=\"oth\">193<\/td><td class=\"oth\">34<\/td><\/tr>\n<tr><td class=\"num\">138.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluazifop-P-butyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/79241-46-6\/Fluazifop-P-butyl\" target=\"_blank\" rel=\"noopener\">Fluazifop-P-butyl<\/a><\/td><td class=\"oth\">6.42<\/td><td class=\"oth\">383.1<\/td><td class=\"oth\">268.2<\/td><td class=\"oth\">8<\/td><td class=\"oth\">383.1<\/td><td class=\"oth\">282.2<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">139.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorfenapyr\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/122453-73-0\/Chlorfenapyr\" target=\"_blank\" rel=\"noopener\">Chlorfenapyr<\/a><\/td><td class=\"oth\">6.46<\/td><td class=\"oth\">247<\/td><td class=\"oth\">227.1<\/td><td class=\"oth\">12<\/td><td class=\"oth\">137<\/td><td class=\"oth\">75<\/td><td class=\"oth\">28<\/td><\/tr>\n<tr><td class=\"num\">140.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethylan\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72-56-0\/Ethylan\" target=\"_blank\" rel=\"noopener\">Ethylan<\/a><\/td><td class=\"oth\">6.46<\/td><td class=\"oth\">223<\/td><td class=\"oth\">167<\/td><td class=\"oth\">12<\/td><td class=\"oth\">223<\/td><td class=\"oth\">193<\/td><td class=\"oth\">28<\/td><\/tr>\n<tr><td class=\"num\">141.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nitrofen\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1836-75-5\/Nitrofen\" target=\"_blank\" rel=\"noopener\">Nitrofen<\/a><\/td><td class=\"oth\">6.49<\/td><td class=\"oth\">283<\/td><td class=\"oth\">202<\/td><td class=\"oth\">10<\/td><td class=\"oth\">202<\/td><td class=\"oth\">139.1<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">142.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorthiophos 1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60238-56-4\/Chlorthiophos 1\" target=\"_blank\" rel=\"noopener\">Chlorthiophos 1<\/a><\/td><td class=\"oth\">6.50<\/td><td class=\"oth\">256.9<\/td><td class=\"oth\">165<\/td><td class=\"oth\">26<\/td><td class=\"oth\">256.9<\/td><td class=\"oth\">239<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">143.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorobenzilate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/510-15-6\/Chlorobenzilate\" target=\"_blank\" rel=\"noopener\">Chlorobenzilate<\/a><\/td><td class=\"oth\">6.52<\/td><td class=\"oth\">251<\/td><td class=\"oth\">139<\/td><td class=\"oth\">14<\/td><td class=\"oth\">139<\/td><td class=\"oth\">111<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">144.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Endrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72-20-8\/Endrin\" target=\"_blank\" rel=\"noopener\">Endrin<\/a><\/td><td class=\"oth\">6.55<\/td><td class=\"oth\">263<\/td><td class=\"oth\">193<\/td><td class=\"oth\">30<\/td><td class=\"oth\">245<\/td><td class=\"oth\">173<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">145.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/563-12-2\/Ethion\" target=\"_blank\" rel=\"noopener\">Ethion<\/a><\/td><td class=\"oth\">6.58<\/td><td class=\"oth\">231<\/td><td class=\"oth\">129<\/td><td class=\"oth\">24<\/td><td class=\"oth\">153<\/td><td class=\"oth\">97<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">146.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4,4&amp;apos;-DDD\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72-54-8\/4,4&amp;apos;-DDD\" target=\"_blank\" rel=\"noopener\">4,4&#8242;-DDD<\/a><\/td><td class=\"oth\">6.59<\/td><td class=\"oth\">235<\/td><td class=\"oth\">165.1<\/td><td class=\"oth\">21<\/td><td class=\"oth\">235<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">147.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorthiophos 2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60238-56-4\/Chlorthiophos 2\" target=\"_blank\" rel=\"noopener\">Chlorthiophos 2<\/a><\/td><td class=\"oth\">6.61<\/td><td class=\"oth\">325<\/td><td class=\"oth\">269<\/td><td class=\"oth\">14<\/td><td class=\"oth\">297<\/td><td class=\"oth\">269<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">148.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4&amp;apos;-DDT\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/789-02-6\/2,4&amp;apos;-DDT\" target=\"_blank\" rel=\"noopener\">2,4&#8242;-DDT<\/a><\/td><td class=\"oth\">6.62<\/td><td class=\"oth\">235<\/td><td class=\"oth\">165.1<\/td><td class=\"oth\">21<\/td><td class=\"oth\">235<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">149.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Triazophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/24017-47-8\/Triazophos\" target=\"_blank\" rel=\"noopener\">Triazophos<\/a><\/td><td class=\"oth\">6.65<\/td><td class=\"oth\">256.9<\/td><td class=\"oth\">161.7<\/td><td class=\"oth\">8<\/td><td class=\"oth\">161<\/td><td class=\"oth\">134.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">150.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for cis-Nonachlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5103-73-1\/cis-Nonachlor\" target=\"_blank\" rel=\"noopener\">cis-Nonachlor<\/a><\/td><td class=\"oth\">6.65<\/td><td class=\"oth\">409<\/td><td class=\"oth\">263<\/td><td class=\"oth\">25<\/td><td class=\"oth\">409<\/td><td class=\"oth\">300<\/td><td class=\"oth\">23<\/td><\/tr>\n<tr><td class=\"num\">151.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Sulprofos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/35400-43-2\/Sulprofos\" target=\"_blank\" rel=\"noopener\">Sulprofos<\/a><\/td><td class=\"oth\">6.66<\/td><td class=\"oth\">322<\/td><td class=\"oth\">156<\/td><td class=\"oth\">8<\/td><td class=\"oth\">156<\/td><td class=\"oth\">141<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">152.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carfentrazone ethyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/128639-02-1\/Carfentrazone ethyl\" target=\"_blank\" rel=\"noopener\">Carfentrazone ethyl<\/a><\/td><td class=\"oth\">6.67<\/td><td class=\"oth\">340.2<\/td><td class=\"oth\">312.2<\/td><td class=\"oth\">10<\/td><td class=\"oth\">330<\/td><td class=\"oth\">310.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">153.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Endrin aldehyde\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7421-93-4\/Endrin aldehyde\" target=\"_blank\" rel=\"noopener\">Endrin aldehyde<\/a><\/td><td class=\"oth\">6.68<\/td><td class=\"oth\">344.9<\/td><td class=\"oth\">243.1<\/td><td class=\"oth\">17<\/td><td class=\"oth\">344.9<\/td><td class=\"oth\">244.9<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">154.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4,4&amp;apos;-Methoxychlor olefin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2132-70-9\/4,4&amp;apos;-Methoxychlor olefin\" target=\"_blank\" rel=\"noopener\">4,4&#8242;-Methoxychlor olefin<\/a><\/td><td class=\"oth\">6.70<\/td><td class=\"oth\">308<\/td><td class=\"oth\">223.1<\/td><td class=\"oth\">30<\/td><td class=\"oth\">238.1<\/td><td class=\"oth\">152.1<\/td><td class=\"oth\">35<\/td><\/tr>\n<tr><td class=\"num\">155.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carbophenothion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/786-19-6\/Carbophenothion\" target=\"_blank\" rel=\"noopener\">Carbophenothion<\/a><\/td><td class=\"oth\">6.70<\/td><td class=\"oth\">342<\/td><td class=\"oth\">157<\/td><td class=\"oth\">10<\/td><td class=\"oth\">125<\/td><td class=\"oth\">97<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">156.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norflurazon\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/27314-13-2\/Norflurazon\" target=\"_blank\" rel=\"noopener\">Norflurazon<\/a><\/td><td class=\"oth\">6.74<\/td><td class=\"oth\">303<\/td><td class=\"oth\">145<\/td><td class=\"oth\">17<\/td><td class=\"oth\">145<\/td><td class=\"oth\">95<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">157.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Edifenphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/17109-49-8\/Edifenphos\" target=\"_blank\" rel=\"noopener\">Edifenphos<\/a><\/td><td class=\"oth\">6.75<\/td><td class=\"oth\">310<\/td><td class=\"oth\">109<\/td><td class=\"oth\">29<\/td><td class=\"oth\">173<\/td><td class=\"oth\">109<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">158.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Lenacil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2164-08-1\/Lenacil\" target=\"_blank\" rel=\"noopener\">Lenacil<\/a><\/td><td class=\"oth\">6.76<\/td><td class=\"oth\">153<\/td><td class=\"oth\">135.7<\/td><td class=\"oth\">14<\/td><td class=\"oth\">135.8<\/td><td class=\"oth\">52.9<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">159.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4,4&amp;apos;-DDT\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-29-3\/4,4&amp;apos;-DDT\" target=\"_blank\" rel=\"noopener\">4,4&#8242;-DDT<\/a><\/td><td class=\"oth\">6.61<\/td><td class=\"oth\">235<\/td><td class=\"oth\">165.1<\/td><td class=\"oth\">21<\/td><td class=\"oth\">235<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">160.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Endosulfan sulfate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1031-07-8\/Endosulfan sulfate\" target=\"_blank\" rel=\"noopener\">Endosulfan sulfate<\/a><\/td><td class=\"oth\">6.81<\/td><td class=\"oth\">272<\/td><td class=\"oth\">237<\/td><td class=\"oth\">10<\/td><td class=\"oth\">241<\/td><td class=\"oth\">206<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">161.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexazinone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51235-04-2\/Hexazinone\" target=\"_blank\" rel=\"noopener\">Hexazinone<\/a><\/td><td class=\"oth\">6.83<\/td><td class=\"oth\">171.1<\/td><td class=\"oth\">71.1<\/td><td class=\"oth\">16<\/td><td class=\"oth\">128<\/td><td class=\"oth\">83<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">162.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Piperonyl butoxide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51-03-6\/Piperonyl butoxide\" target=\"_blank\" rel=\"noopener\">Piperonyl butoxide<\/a><\/td><td class=\"oth\">6.83<\/td><td class=\"oth\">176.1<\/td><td class=\"oth\">103<\/td><td class=\"oth\">26<\/td><td class=\"oth\">176.1<\/td><td class=\"oth\">131.1<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">163.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propargite\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2312-35-8\/Propargite\" target=\"_blank\" rel=\"noopener\">Propargite<\/a><\/td><td class=\"oth\">6.83<\/td><td class=\"oth\">201.1<\/td><td class=\"oth\">81.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">135.1<\/td><td class=\"oth\">107<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">164.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Resmethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/10453-86-8\/Resmethrin\" target=\"_blank\" rel=\"noopener\">Resmethrin<\/a><\/td><td class=\"oth\">6.83<\/td><td class=\"oth\">143.1<\/td><td class=\"oth\">128<\/td><td class=\"oth\">10<\/td><td class=\"oth\">123.2<\/td><td class=\"oth\">81.2<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">165.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tebuconazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/107534-96-3\/Tebuconazole\" target=\"_blank\" rel=\"noopener\">Tebuconazole<\/a><\/td><td class=\"oth\">6.85<\/td><td class=\"oth\">250.1<\/td><td class=\"oth\">125.2<\/td><td class=\"oth\">22<\/td><td class=\"oth\">125<\/td><td class=\"oth\">89<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">166.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nitralin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/4726-14-1\/Nitralin\" target=\"_blank\" rel=\"noopener\">Nitralin<\/a><\/td><td class=\"oth\">6.95<\/td><td class=\"oth\">316.1<\/td><td class=\"oth\">274<\/td><td class=\"oth\">8<\/td><td class=\"oth\">274<\/td><td class=\"oth\">216.2<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">167.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Captafol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2425-06-1\/Captafol\" target=\"_blank\" rel=\"noopener\">Captafol<\/a><\/td><td class=\"oth\">6.99<\/td><td class=\"oth\">150.8<\/td><td class=\"oth\">78.9<\/td><td class=\"oth\">18<\/td><td class=\"oth\">79<\/td><td class=\"oth\">77.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">168.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for TPP (IS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/115-86-6\/TPP\" target=\"_blank\" rel=\"noopener\">TPP (IS)<\/a><\/td><td class=\"oth\">6.99<\/td><td class=\"oth\">326<\/td><td class=\"oth\">169<\/td><td class=\"oth\">30<\/td><td class=\"oth\">326<\/td><td class=\"oth\">215<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">169.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Iprodione\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/36734-19-7\/Iprodione\" target=\"_blank\" rel=\"noopener\">Iprodione<\/a><\/td><td class=\"oth\">7.01<\/td><td class=\"oth\">314<\/td><td class=\"oth\">245<\/td><td class=\"oth\">14<\/td><td class=\"oth\">187<\/td><td class=\"oth\">124.1<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">170.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bifenthrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/82657-04-3\/Bifenthrin\" target=\"_blank\" rel=\"noopener\">Bifenthrin<\/a><\/td><td class=\"oth\">7.05<\/td><td class=\"oth\">181.1<\/td><td class=\"oth\">166.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">165.1<\/td><td class=\"oth\">115.1<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">171.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenpropathrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/39515-41-8\/Fenpropathrin\" target=\"_blank\" rel=\"noopener\">Fenpropathrin<\/a><\/td><td class=\"oth\">7.05<\/td><td class=\"oth\">265<\/td><td class=\"oth\">210<\/td><td class=\"oth\">8<\/td><td class=\"oth\">181<\/td><td class=\"oth\">152<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">172.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyridaphenthion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/119-12-0\/Pyridaphenthion\" target=\"_blank\" rel=\"noopener\">Pyridaphenthion<\/a><\/td><td class=\"oth\">7.05<\/td><td class=\"oth\">340.1<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">77.1<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">173.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tetramethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7696-12-0\/Tetramethrin\" target=\"_blank\" rel=\"noopener\">Tetramethrin<\/a><\/td><td class=\"oth\">7.06<\/td><td class=\"oth\">164<\/td><td class=\"oth\">77<\/td><td class=\"oth\">25<\/td><td class=\"oth\">164<\/td><td class=\"oth\">107<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">174.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bromopropylate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/18181-80-1\/Bromopropylate\" target=\"_blank\" rel=\"noopener\">Bromopropylate<\/a><\/td><td class=\"oth\">7.08<\/td><td class=\"oth\">340.8<\/td><td class=\"oth\">183<\/td><td class=\"oth\">15<\/td><td class=\"oth\">183<\/td><td class=\"oth\">154.9<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">175.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Azinphos-ethyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2642-71-9\/Azinphos-ethyl\" target=\"_blank\" rel=\"noopener\">Azinphos-ethyl<\/a><\/td><td class=\"oth\">7.80<\/td><td class=\"oth\">160<\/td><td class=\"oth\">77<\/td><td class=\"oth\">18<\/td><td class=\"oth\">132<\/td><td class=\"oth\">77<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">176.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for EPN\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2104-64-5\/EPN\" target=\"_blank\" rel=\"noopener\">EPN<\/a><\/td><td class=\"oth\">7.11<\/td><td class=\"oth\">169<\/td><td class=\"oth\">77<\/td><td class=\"oth\">22<\/td><td class=\"oth\">169<\/td><td class=\"oth\">141<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">177.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phosmet\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/732-11-6\/Phosmet\" target=\"_blank\" rel=\"noopener\">Phosmet<\/a><\/td><td class=\"oth\">7.11<\/td><td class=\"oth\">160<\/td><td class=\"oth\">77<\/td><td class=\"oth\">24<\/td><td class=\"oth\">160<\/td><td class=\"oth\">133<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">178.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methoxychlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72-43-5\/Methoxychlor\" target=\"_blank\" rel=\"noopener\">Methoxychlor<\/a><\/td><td class=\"oth\">7.12<\/td><td class=\"oth\">227<\/td><td class=\"oth\">141<\/td><td class=\"oth\">33<\/td><td class=\"oth\">227<\/td><td class=\"oth\">169<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">179.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tebufenpyrad\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/119168-77-3\/Tebufenpyrad\" target=\"_blank\" rel=\"noopener\">Tebufenpyrad<\/a><\/td><td class=\"oth\">7.12<\/td><td class=\"oth\">333<\/td><td class=\"oth\">276<\/td><td class=\"oth\">8<\/td><td class=\"oth\">276<\/td><td class=\"oth\">171<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">180.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Endrin ketone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53494-70-5\/Endrin ketone\" target=\"_blank\" rel=\"noopener\">Endrin ketone<\/a><\/td><td class=\"oth\">7.13<\/td><td class=\"oth\">317<\/td><td class=\"oth\">101<\/td><td class=\"oth\">21<\/td><td class=\"oth\">315<\/td><td class=\"oth\">279<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">181.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenothrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/26002-80-2\/Phenothrin\" target=\"_blank\" rel=\"noopener\">Phenothrin<\/a><\/td><td class=\"oth\">7.19<\/td><td class=\"oth\">183.1<\/td><td class=\"oth\">168.1<\/td><td class=\"oth\">12<\/td><td class=\"oth\">123.2<\/td><td class=\"oth\">81.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">182.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tetradifon\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/116-29-0\/Tetradifon\" target=\"_blank\" rel=\"noopener\">Tetradifon<\/a><\/td><td class=\"oth\">7.25<\/td><td class=\"oth\">227<\/td><td class=\"oth\">199<\/td><td class=\"oth\">10<\/td><td class=\"oth\">159<\/td><td class=\"oth\">131<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">183.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyriproxyfen\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95737-68-1\/Pyriproxyfen\" target=\"_blank\" rel=\"noopener\">Pyriproxyfen<\/a><\/td><td class=\"oth\">7.28<\/td><td class=\"oth\">226.1<\/td><td class=\"oth\">186.1<\/td><td class=\"oth\">16<\/td><td class=\"oth\">136.1<\/td><td class=\"oth\">78<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">184.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phosalone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2310-17-0\/Phosalone\" target=\"_blank\" rel=\"noopener\">Phosalone<\/a><\/td><td class=\"oth\">7.29<\/td><td class=\"oth\">367<\/td><td class=\"oth\">111<\/td><td class=\"oth\">36<\/td><td class=\"oth\">182<\/td><td class=\"oth\">111<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">185.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Leptophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/21609-90-5\/Leptophos\" target=\"_blank\" rel=\"noopener\">Leptophos<\/a><\/td><td class=\"oth\">7.31<\/td><td class=\"oth\">377<\/td><td class=\"oth\">269<\/td><td class=\"oth\">37<\/td><td class=\"oth\">171<\/td><td class=\"oth\">77<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">186.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03bb-Cyhalothrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91465-08-6\/\u03bb-Cyhalothrin\" target=\"_blank\" rel=\"noopener\">\u03bb-Cyhalothrin<\/a><\/td><td class=\"oth\">7.31<\/td><td class=\"oth\">197.1<\/td><td class=\"oth\">141.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">197<\/td><td class=\"oth\">91<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">187.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acrinathrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/101007-06-1\/Acrinathrin\" target=\"_blank\" rel=\"noopener\">Acrinathrin<\/a><\/td><td class=\"oth\">7.32<\/td><td class=\"oth\">289.1<\/td><td class=\"oth\">93<\/td><td class=\"oth\">10<\/td><td class=\"oth\">289<\/td><td class=\"oth\">91<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">188.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyrazophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13457-18-6\/Pyrazophos\" target=\"_blank\" rel=\"noopener\">Pyrazophos<\/a><\/td><td class=\"oth\">7.41<\/td><td class=\"oth\">265.1<\/td><td class=\"oth\">210.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">221.1<\/td><td class=\"oth\">193.1<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">189.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mirex\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2385-85-5\/Mirex\" target=\"_blank\" rel=\"noopener\">Mirex<\/a><\/td><td class=\"oth\">7.44<\/td><td class=\"oth\">274<\/td><td class=\"oth\">239<\/td><td class=\"oth\">15<\/td><td class=\"oth\">272<\/td><td class=\"oth\">237<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">190.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenarimol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60168-88-9\/Fenarimol\" target=\"_blank\" rel=\"noopener\">Fenarimol<\/a><\/td><td class=\"oth\">7.46<\/td><td class=\"oth\">219<\/td><td class=\"oth\">107.1<\/td><td class=\"oth\">12<\/td><td class=\"oth\">139<\/td><td class=\"oth\">111<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">191.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Azinphos-methyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/86-50-0\/Azinphos-methyl\" target=\"_blank\" rel=\"noopener\">Azinphos-methyl<\/a><\/td><td class=\"oth\">7.46<\/td><td class=\"oth\">160<\/td><td class=\"oth\">77<\/td><td class=\"oth\">18<\/td><td class=\"oth\">132<\/td><td class=\"oth\">77<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">192.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyraclofos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/77458-01-6\/Pyraclofos\" target=\"_blank\" rel=\"noopener\">Pyraclofos<\/a><\/td><td class=\"oth\">7.47<\/td><td class=\"oth\">360<\/td><td class=\"oth\">139<\/td><td class=\"oth\">14<\/td><td class=\"oth\">194<\/td><td class=\"oth\">138<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">193.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for cis-Permethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/61949-76-6\/cis-Permethrin\" target=\"_blank\" rel=\"noopener\">cis-Permethrin<\/a><\/td><td class=\"oth\">7.54<\/td><td class=\"oth\">183.1<\/td><td class=\"oth\">153.1<\/td><td class=\"oth\">12<\/td><td class=\"oth\">163<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">194.<\/td><td class=\"cmpd\">&lt;a class=&quot;cmpd_link&quot; title=&quot;View compound information for <i>trans<\/i>-Permethrin&#8221; title=&#8221;View compound information for <i>trans<\/i>-Permethrin&#8221; href=&#8221;https:\/\/ez.restek.com\/compound\/view\/en\/61949-77-7\/<i>trans-Permethrin&#8221;&gt;<i>trans<\/i>-Permethrin<\/a><\/td><td class=\"oth\">7.58<\/td><td class=\"oth\">183.1<\/td><td class=\"oth\">153.1<\/td><td class=\"oth\">12<\/td><td class=\"oth\">163<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">195.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyridaben\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/96489-71-3\/Pyridaben\" target=\"_blank\" rel=\"noopener\">Pyridaben<\/a><\/td><td class=\"oth\">7.62<\/td><td class=\"oth\">147<\/td><td class=\"oth\">117<\/td><td class=\"oth\">20<\/td><td class=\"oth\">147<\/td><td class=\"oth\">119<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">196.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Coumaphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-72-4\/Coumaphos\" target=\"_blank\" rel=\"noopener\">Coumaphos<\/a><\/td><td class=\"oth\">7.66<\/td><td class=\"oth\">362<\/td><td class=\"oth\">109<\/td><td class=\"oth\">17<\/td><td class=\"oth\">210<\/td><td class=\"oth\">182<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">197.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluquinconazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/136426-54-5\/Fluquinconazole\" target=\"_blank\" rel=\"noopener\">Fluquinconazole<\/a><\/td><td class=\"oth\">7.66<\/td><td class=\"oth\">340<\/td><td class=\"oth\">108<\/td><td class=\"oth\">42<\/td><td class=\"oth\">340<\/td><td class=\"oth\">298<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">198.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Prochloraz\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/67747-09-5\/Prochloraz\" target=\"_blank\" rel=\"noopener\">Prochloraz<\/a><\/td><td class=\"oth\">7.67<\/td><td class=\"oth\">308<\/td><td class=\"oth\">70<\/td><td class=\"oth\">13<\/td><td class=\"oth\">180<\/td><td class=\"oth\">138<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">199.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cyfluthrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/68359-37-5\/Cyfluthrin\" target=\"_blank\" rel=\"noopener\">Cyfluthrin<\/a><\/td><td class=\"oth\">7.73<\/td><td class=\"oth\">226.1<\/td><td class=\"oth\">199<\/td><td class=\"oth\">8<\/td><td class=\"oth\">226<\/td><td class=\"oth\">151<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">200.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cypermethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52315-07-8\/Cypermethrin\" target=\"_blank\" rel=\"noopener\">Cypermethrin<\/a><\/td><td class=\"oth\">7.83<\/td><td class=\"oth\">181.1<\/td><td class=\"oth\">127<\/td><td class=\"oth\">28<\/td><td class=\"oth\">181.1<\/td><td class=\"oth\">152.1<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">201.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flucythrinate 1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/70124-77-5\/Flucythrinate 1\" target=\"_blank\" rel=\"noopener\">Flucythrinate 1<\/a><\/td><td class=\"oth\">7.86<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">157.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">157.1<\/td><td class=\"oth\">107.1<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">202.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acequinocyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57960-19-7\/Acequinocyl\" target=\"_blank\" rel=\"noopener\">Acequinocyl<\/a><\/td><td class=\"oth\">7.89<\/td><td class=\"oth\">342.4<\/td><td class=\"oth\">188.1<\/td><td class=\"oth\">14<\/td><td class=\"oth\">188<\/td><td class=\"oth\">132<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">203.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Etofenprox\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/80844-07-1\/Etofenprox\" target=\"_blank\" rel=\"noopener\">Etofenprox<\/a><\/td><td class=\"oth\">7.90<\/td><td class=\"oth\">163.1<\/td><td class=\"oth\">107<\/td><td class=\"oth\">18<\/td><td class=\"oth\">163.1<\/td><td class=\"oth\">135.1<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">204.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flucythrinate 2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/70124-77-5\/Flucythrinate 2\" target=\"_blank\" rel=\"noopener\">Flucythrinate 2<\/a><\/td><td class=\"oth\">7.91<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">157.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">157.1<\/td><td class=\"oth\">107.1<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">205.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluridone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59756-60-4\/Fluridone\" target=\"_blank\" rel=\"noopener\">Fluridone<\/a><\/td><td class=\"oth\">8.03<\/td><td class=\"oth\">328.1<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">40<\/td><td class=\"oth\">328.1<\/td><td class=\"oth\">259<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">206.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenvalerate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51630-58-1\/Fenvalerate\" target=\"_blank\" rel=\"noopener\">Fenvalerate<\/a><\/td><td class=\"oth\">8.10<\/td><td class=\"oth\">169.1<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">167.1<\/td><td class=\"oth\">125<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">207.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tau-fluvalinate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/102851-06-9\/Tau-fluvalinate\" target=\"_blank\" rel=\"noopener\">Tau-fluvalinate<\/a><\/td><td class=\"oth\">8.15<\/td><td class=\"oth\">252<\/td><td class=\"oth\">55<\/td><td class=\"oth\">17<\/td><td class=\"oth\">250.1<\/td><td class=\"oth\">55<\/td><td class=\"oth\">23<\/td><\/tr>\n<tr><td class=\"num\">208.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenvalerate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51630-58-1\/Fenvalerate\" target=\"_blank\" rel=\"noopener\">Fenvalerate<\/a><\/td><td class=\"oth\">8.16<\/td><td class=\"oth\">169.1<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">167.1<\/td><td class=\"oth\">125<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">209.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Deltamethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52918-63-5\/Deltamethrin\" target=\"_blank\" rel=\"noopener\">Deltamethrin<\/a><\/td><td class=\"oth\">8.33<\/td><td class=\"oth\">252.9<\/td><td class=\"oth\">93.1<\/td><td class=\"oth\">19<\/td><td class=\"oth\">181.1<\/td><td class=\"oth\">152<\/td><td class=\"oth\">20<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>LPGC Rtx-5ms column kit, includes 15 m x 0.53 mm ID x 1.00 \u03bcm analytical column w\/1 m x 0.53 mm ID integrated transfer line and 5 m x 0.18 mm ID Hydroguard restrictor factory connected via SilTite connector (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/11800\" rel=\"noopener\">cat.# 11800<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>GC multiresidue pesticide kit (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/32562\" rel=\"noopener\">cat.# 32562<\/a>)<\/td><\/tr><tr><td><\/td><td>Triphenylphosphate (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/33258\" rel=\"noopener\">cat.# 33258<\/a>)<\/td><\/tr><tr><td><\/td><td>Anthracene<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Acetonitrile<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>1 \u00b5g\/mL<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L splitless (hold 0.5  min)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 4.0 mm ID single taper inlet liner w\/ wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23447\" rel=\"noopener\">cat.# 23447<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>80 &#176;C (hold 1 min) to 320 &#176;C at 35 &#176;C\/min (hold 5 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>2 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>TSQ 8000<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">SIM Program:<\/th><td colspan=\"2\">35-550 m\/z<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>290 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>325 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Solvent Delay Time:<\/th><td>2  min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>PFTBA <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Thermo Scientific TSQ 8000 Triple Quadrupole GC-MS<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Sample preparation: 10 g of homogenized strawberries were fortified with the internal standards at 20 ppb and then extracted with 10 mL of acetonitrile and QuEChERS EN 15662 salts (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/25850\" rel=\"noopener\">cat.# 25850<\/a>). After centrifugation, 1 mL of supernatant was added to a 2 mL dSPE vial containing magnesium sulfate and PSA (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/26124\" rel=\"noopener\">cat.# 26124<\/a>) for cleanup. The cleaned extract was spiked with GC multiresidue pesticide mix at 1 ppm.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>32562<\/li><li>33258<\/li><li>11800<\/li><li>23447<\/li><li>25850<\/li><li>26124<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>LPGC<\/li><li>multiresidue<\/li><li>pesticides<\/li><li>pesticides-food-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_fs0572.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Cette analyse des multi-r\u00e9sidus de pesticides dans les aliments est 3 fois plus rapide qu&#8217;une analyse avec des m\u00e9thodes conventionnelles, \u00e9luant 209 compos\u00e9s dans les fraises en environ 8 minutes. Un kit basse-pression pr\u00e9-assembl\u00e9 en simplifie la mise en place.<\/p>\n","protected":false},"author":11,"featured_media":7029,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[462],"tags":[],"industries-application":[2214,2216],"post-badge":[],"resource-type":[],"product-library":[2456,2444],"resource-technique":[2316,2319],"ppma_author":[414],"class_list":["post-43611","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-fr","industries-application-industrie-agroalimentaire","industries-application-securite-alimentaire","product-library-colonnes-gc","product-library-produits-pour-la-chromatographie-en-phase-gazeuse","resource-technique-chromatographie-en-phase-gazeuse-gc","resource-technique-gc-ms-basse-pression-lpgc"],"acf":[],"taxonomy_info":{"category":[{"value":462,"label":"Articles"}],"industries-application":[{"value":2214,"label":"Industrie Agroalimentaire"},{"value":2216,"label":"S\u00e9curit\u00e9 alimentaire"}],"product-library":[{"value":2456,"label":"Colonnes GC"},{"value":2444,"label":"Produits pour la chromatographie en phase gazeuse"}],"resource-technique":[{"value":2316,"label":"Chromatographie en phase gazeuse (GC)"},{"value":2319,"label":"GC-MS basse-pression (LPGC)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-FSFA3504-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":462,"name":"Articles","slug":"articles-fr","term_group":0,"term_taxonomy_id":462,"taxonomy":"category","description":"","parent":0,"count":506,"filter":"raw","cat_ID":462,"category_count":506,"category_description":"","cat_name":"Articles","category_nicename":"articles-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43611","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=43611"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43611\/revisions"}],"predecessor-version":[{"id":85647,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43611\/revisions\/85647"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/7029"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=43611"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=43611"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=43611"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=43611"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=43611"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=43611"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=43611"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=43611"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=43611"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}