{"id":43620,"date":"2024-07-12T00:00:00","date_gmt":"2024-07-12T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/simultaneous-analysis-of-pesticides-and-mycotoxins-in-primary-processed-foods-the-case-of-bee-pollen\/"},"modified":"2026-01-03T15:47:53","modified_gmt":"2026-01-03T15:47:53","slug":"simultaneous-analysis-of-pesticides-and-mycotoxins-in-primary-processed-foods-the-case-of-bee-pollen","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/articoli\/fsot4324\/simultaneous-analysis-of-pesticides-and-mycotoxins-in-primary-processed-foods-the-case-of-bee-pollen","title":{"rendered":"Simultaneous Analysis of Pesticides and Mycotoxins in Primary Processed Foods: The Case of Bee Pollen"},"content":{"rendered":"\n<p><strong>Author(s): <\/strong>Maria Antonietta Carrera<sup>1<\/sup>, Jos\u00e9 Antonio Martinez Martinez<sup>2<\/sup>, Mar\u00eda Dolores Hernando<sup>1<\/sup>, Amadeo R. Fern\u00e1ndez-Alba<sup>2<\/sup><br>1. Department of Desertification and Geo-ecology, Experimental Station of Arid Zones, CSIC, Almer\u00eda, Spain, 2. European Union Reference Laboratory for Pesticide Residues in Fruit &amp; Vegetables Agrifood Campus of International Excellence (ceiA3), Department of Chemistry and Physics, University of Almeria, Almeria, Spain.<\/p>\n\n\n\n<p><strong>Published By:<\/strong> Heliyon<\/p>\n\n\n\n<p><strong>Issue:<\/strong> 13, Volume 10<\/p>\n\n\n\n<p><strong>Year of Publication:<\/strong> 2024<\/p>\n\n\n\n<p><strong>Link:<\/strong> <a href=\"https:\/\/doi.org\/10.1016\/j.heliyon.2024.e33512\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.1016\/j.heliyon.2024.e33512<\/a><\/p>\n\n\n\n<p><strong>Abstract:<\/strong> Primary Processed Foods are a class of food items that are ready for consumption after minimal processing in the supply chain. These products are ubiquitous in our daily diet, but so far a limited number of studies dealt with the optimization of quality control methods to check their content of contaminants. Among primary processed foods, bee pollen is a nutritionally acclaimed food supplement, whose contamination with pesticides and mycotoxins has been largely proven. For this reason, the present study aimed at optimizing for the first time a comprehensive LC-MS\/MS method capable of analyzing 282 pesticides and 8 mycotoxins in bee pollen. To obtain a suitable method, two extraction procedures (QuEChERS and Accelerated Solvent Extraction), as well as different chromatographic gradients and columns, were tested. The optimized methodology, comprehending an extraction based on semi-automated QuEChERS, and an analytical method including inert LC column technology, was validated and applied to a sample set of 34 bee pollens. The analyzed samples collectively showed the presence of 41 pesticides and 1 mycotoxin.<\/p>\n\n\n\n<p><strong>Acknowledgment(s):<\/strong> This analysis features Restek\u2019s Raptor Inert ARC-18 LC columns <a href=\"https:\/\/www.restek.com\/p\/9314A12-T\" target=\"_blank\" rel=\"noopener\">(cat.# 9314A12-T)<\/a>. Learn more about our inert column technology at <a href=\"https:\/\/www.restek.com\/articles\/accurately-analyze-metal-sensitive-compounds-with-resteks-new-inert-lc-columns\" target=\"_blank\" rel=\"noopener\">www.restek.com\/inert<\/a><\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Produits mentionn\u00e9s<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9314A12-T\">                                R\u00e9f. 9314A12-T                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor ARC-18 Inerte, 2.7 \u00b5m, Colonne HPLC 2.1 x 100 mm<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9314A12-T\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>This optimized LC-MS\/MS method analyzes 282 pesticides and 8 mycotoxins in bee pollen.<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[788],"tags":[],"industries-application":[2290,2292],"post-badge":[],"resource-type":[568],"product-library":[2535,2517,2544,2519],"resource-technique":[2334,2364,2369],"ppma_author":[714,700,715,655],"class_list":["post-43620","post","type-post","status-publish","format-standard","hentry","category-articoli","industries-application-food-beverage-it","industries-application-sicurezza-alimentare-it","resource-type-third-party-peer-reviewed-publications","product-library-colonne-lc","product-library-prodotti-per-cromatografia-liquida","product-library-prodotti-quechers","product-library-prodotti-per-la-preparazione-del-campione","resource-technique-cromatografia-liquida-lc","resource-technique-ms-ms-it","resource-technique-quechers-it"],"acf":[],"taxonomy_info":{"category":[{"value":788,"label":"Articoli"}],"industries-application":[{"value":2290,"label":"Food &amp; Beverage"},{"value":2292,"label":"Sicurezza alimentare"}],"resource-type":[{"value":568,"label":"Third-Party &amp; Peer Reviewed Publications"}],"product-library":[{"value":2535,"label":"Colonne LC"},{"value":2517,"label":"Prodotti per Cromatografia Liquida"},{"value":2544,"label":"Prodotti QuEChERS"},{"value":2519,"label":"Prodotti per la Preparazione del Campione"}],"resource-technique":[{"value":2334,"label":"Cromatografia Liquida (LC)"},{"value":2364,"label":"MS\/MS"},{"value":2369,"label":"QuEChERS"}]},"featured_image_src_large":false,"author_info":{"display_name":"Audrey Crater","author_link":"https:\/\/discover.restek.com\/fr\/author\/audrey-craterrestek-com\/"},"comment_info":0,"category_info":[{"term_id":788,"name":"Articoli","slug":"articoli","term_group":0,"term_taxonomy_id":788,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":788,"category_count":457,"category_description":"","cat_name":"Articoli","category_nicename":"articoli","category_parent":0}],"tag_info":false,"authors":[{"term_id":714,"user_id":0,"is_guest":1,"slug":"maria-antonietta-carrera","display_name":"Maria Antonietta Carrera","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""},{"term_id":700,"user_id":0,"is_guest":1,"slug":"jose-antonio-martinez-martinez","display_name":"Jos\u00e9 Antonio Martinez Martinez","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""},{"term_id":715,"user_id":0,"is_guest":1,"slug":"maria-dolores-hernando","display_name":"Mar\u00eda Dolores Hernando","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""},{"term_id":655,"user_id":0,"is_guest":1,"slug":"amadeo-r-fernandez-alba","display_name":"Amadeo R. Fern\u00e1ndez-Alba","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43620","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=43620"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43620\/revisions"}],"predecessor-version":[{"id":79374,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43620\/revisions\/79374"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=43620"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=43620"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=43620"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=43620"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=43620"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=43620"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=43620"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=43620"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=43620"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}