{"id":43650,"date":"2020-10-27T00:00:00","date_gmt":"2020-10-27T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/quel-degre-de-sensibilite-pour-un-detecteur-de-fuites-de-gaz\/"},"modified":"2026-01-28T19:58:34","modified_gmt":"2026-01-28T19:58:34","slug":"quel-degre-de-sensibilite-pour-un-detecteur-de-fuites-de-gaz","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/articles-fr\/gnar2999-fr\/quel-degre-de-sensibilite-pour-un-detecteur-de-fuites-de-gaz","title":{"rendered":"Quel degr\u00e9 de sensibilit\u00e9 pour un d\u00e9tecteur de fuites de gaz ?"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>Prot\u00e9gez vos donn\u00e9es et vos instruments ; d\u00e9tectez des fuites non d\u00e9cel\u00e9es lors des tests de pression de votre GC.<\/li>\n\n\n\n<li>Appareil \u00e0 prix abordable qui \u00e9vite un remplacement de colonne pr\u00e9matur\u00e9 et des op\u00e9rations de maintenance superflues.<\/li>\n\n\n\n<li>Localisez facilement les micro-fuites.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Dans les appareils de chromatographie en phase gazeuse (GC), les fuites de gaz peuvent provoquer de nombreux probl\u00e8mes analytiques, notamment un d\u00e9calage des temps de r\u00e9tention, des pics d\u00e9form\u00e9s et des mont\u00e9es de ligne de base. Les fuites peuvent \u00e9galement entra\u00eener des d\u00e9penses superflues dus \u00e0 la perte de gaz et \u00e0 la r\u00e9duction de la dur\u00e9e de vie des colonnes. Plus important, les fuites peuvent fausser les donn\u00e9es chromatographiques et conduire \u00e0 des r\u00e9sultats non concluants, voire erron\u00e9s. Les d\u00e9tecteurs \u00e9lectroniques peuvent aider \u00e0 pr\u00e9venir tous ces probl\u00e8mes, mais les mod\u00e8les \u00e0 sensibilit\u00e9 \u00e9lev\u00e9e peuvent \u00eatre tr\u00e8s on\u00e9reux et l\u2019investissement n\u2019est alors pas rentable. Quel niveau de sensibilit\u00e9 est r\u00e9ellement n\u00e9cessaire pour prot\u00e9ger votre \u00e9quipement et vos donn\u00e9es avec un d\u00e9tecteur de fuites portatif ?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Souvent, les d\u00e9tecteurs \u00e9lectroniques sont pr\u00e9sent\u00e9s avec des valeurs nominales de d\u00e9tection en atm.cm3\/s, ce qui n\u2019indique pas clairement si la fuite est r\u00e9ellement probl\u00e9matique. Pour d\u00e9terminer si un d\u00e9tecteur de fuites est capable d\u2019identifier une fuite de gaz significative pour les analyses, il est possible de v\u00e9rifier le taux de chute de pression sur une fuite mesur\u00e9e et contr\u00f4lable. Tr\u00e8s souvent, les fabricants des GC fournissent les instructions de v\u00e9rification du taux de chute de pression, afin de d\u00e9terminer si l\u2019injecteur pr\u00e9sente une fuite. Habituellement, il s\u2019agit de fermer herm\u00e9tiquement toutes les sorties de l\u2019injecteur et de mettre le syst\u00e8me sous pression. Lorsque l\u2019injecteur est sous pression, le d\u00e9bit de gaz vecteur est coup\u00e9 et le taux de chute de pression est surveill\u00e9. Par exemple, selon les instructions fournies par Agilent, une chute de plus de 0.5 psi en 10 minutes indique une fuite significative.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour d\u00e9terminer si la sensibilit\u00e9 du\u00a0d\u00e9tecteur \u00e9lectronique de fuites Restek\u00a0est suffisante pour d\u00e9tecter une fuite du m\u00eame niveau, nous avons cr\u00e9\u00e9 une micro-fuite contr\u00f4l\u00e9e et surveill\u00e9 la pression \u00e0 l\u2019int\u00e9rieur de l\u2019injecteur. Pour cela, nous avons perc\u00e9 le septum au moyen d\u2019une longueur de tube en silice fondue. Cette fuite a ensuite \u00e9t\u00e9 mesur\u00e9e en observant le taux de chute de pression, et ajust\u00e9e en faisant varier la longueur ou le diam\u00e8tre interne du tube. Avec un tube de 3 cm de longueur et de 15 \u03bcm de diam\u00e8tre interne, la fuite cr\u00e9\u00e9e provoquait une chute de pression de 0.3 psi en 10 minutes. Ce niveau aurait \u00e9t\u00e9 acceptable selon le protocole de recherche de fuite fourni par Agilent. Le d\u00e9tecteur \u00e9lectronique de fuites Restek a facilement localis\u00e9 la fuite, ce qui prouve que cet appareil relativement abordable est suffisamment sensible pour d\u00e9tecter des fuites consid\u00e9r\u00e9es comme acceptables selon les protocoles d\u2019essai de certains fabricants (Figure 1).<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1 :<\/strong>\u00a0Le d\u00e9tecteur \u00e9lectronique de fuites de gaz Restek est suffisamment sensible pour identifier une fuite contr\u00f4l\u00e9e de faible d\u00e9bit, qui serait consid\u00e9r\u00e9e comme acceptable selon l\u2019essai de v\u00e9rification du taux de chute de pression de l\u2019instrument.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"700\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR2999-01-1024x700.jpg\" alt=\"\" class=\"wp-image-20808\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR2999-01-1024x700.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR2999-01-300x205.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR2999-01-768x525.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR2999-01-1536x1050.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNAR2999-01.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\">Les d\u00e9tecteurs \u00e9lectroniques de fuites sont des outils indispensables pour garantir l&#8217;\u00e9tanch\u00e9it\u00e9 du syst\u00e8me, car ils sont faciles \u00e0 utiliser et ne n\u00e9cessitent pas de mettre l&#8217;instrument hors service. Le\u00a0d\u00e9tecteur \u00e9lectronique de fuites Restek\u00a0est suffisamment sensible pour trouver les fuites qui peuvent endommager les colonnes et son prix abordable en fait une option tr\u00e8s rentable pour prot\u00e9ger vos colonnes et vos \u00e9chantillons.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Produits mentionn\u00e9s<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">                                R\u00e9f. 28500                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">D\u00e9tecteur \u00e9lectronique de fuites de gaz Restek<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Le d\u00e9tecteur de fuites \u00e9lectronique Restek est suffisamment sensible pour trouver les fuites qui peuvent endommager les colonnes et son prix abordable en fait une option tr\u00e8s rentable pour prot\u00e9ger vos colonnes et vos \u00e9chantillons.<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[462],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2459,2444],"resource-technique":[2316],"ppma_author":[414],"class_list":["post-43650","post","type-post","status-publish","format-standard","hentry","category-articles-fr","product-library-materiel-accessoires-pour-instruments","product-library-produits-pour-la-chromatographie-en-phase-gazeuse","resource-technique-chromatographie-en-phase-gazeuse-gc"],"acf":[],"taxonomy_info":{"category":[{"value":462,"label":"Articles"}],"product-library":[{"value":2459,"label":"Mat\u00e9riel et accessoires pour instruments"},{"value":2444,"label":"Produits pour la chromatographie en phase gazeuse"}],"resource-technique":[{"value":2316,"label":"Chromatographie en phase gazeuse (GC)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":462,"name":"Articles","slug":"articles-fr","term_group":0,"term_taxonomy_id":462,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":462,"category_count":510,"category_description":"","cat_name":"Articles","category_nicename":"articles-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43650","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=43650"}],"version-history":[{"count":8,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43650\/revisions"}],"predecessor-version":[{"id":85702,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43650\/revisions\/85702"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=43650"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=43650"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=43650"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=43650"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=43650"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=43650"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=43650"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=43650"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=43650"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}