{"id":43771,"date":"2021-04-19T14:30:00","date_gmt":"2021-04-19T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/utilisation-dune-nouvelle-phase-stationnaire-hybride-pour-lanalyse-lc-msms-de-pesticides-polaires-dans-les-fruits-et-legumes\/"},"modified":"2026-01-28T21:55:33","modified_gmt":"2026-01-28T21:55:33","slug":"utilisation-dune-nouvelle-phase-stationnaire-hybride-pour-lanalyse-lc-msms-de-pesticides-polaires-dans-les-fruits-et-legumes","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/articles-fr\/gnot3528-fr\/utilisation-dune-nouvelle-phase-stationnaire-hybride-pour-lanalyse-lc-msms-de-pesticides-polaires-dans-les-fruits-et-legumes","title":{"rendered":"Utilisation d\u2019une nouvelle phase stationnaire hybride pour l\u2019analyse LC-MS\/MS de pesticides polaires dans les fruits et l\u00e9gumes"},"content":{"rendered":"\n<p><strong>Auteur(s):<\/strong>&nbsp;V\u00edctor Cutillas, Amadeo R. Fern\u00e1ndez-Alba<\/p>\n\n\n\n<p>University of Almer\u00eda, Department of Chemistry and Physics, Agrifood Campus of International Excellence (ceiA3), Ctra. Sacramento s\/n, La Ca\u00f1ada de San Urbano, Almer\u00eda 04120, Spain<\/p>\n\n\n\n<p><strong>Publi\u00e9 par :<\/strong>&nbsp;MethodsX<\/p>\n\n\n\n<p><strong>Edition :<\/strong>&nbsp;Volume 8<\/p>\n\n\n\n<p><strong>Ann\u00e9e de publication :<\/strong>&nbsp;2021<\/p>\n\n\n\n<p><strong>Lien :<\/strong>&nbsp;<a href=\"https:\/\/doi.org\/10.1016\/j.mex.2021.101306\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.1016\/j.mex.2021.101306<\/a><\/p>\n\n\n\n<p><strong>R\u00e9sum\u00e9 :<\/strong>&nbsp;De nombreux pesticides polaires sont utilis\u00e9s en agriculture. Malheureusement, leurs propri\u00e9t\u00e9s physico-chimiques rendent leur analyse tr\u00e8s complexe si l\u2019on suit les proc\u00e9dures courantes. G\u00e9n\u00e9ralement, les pesticides polaires sont faiblement retenus et peuvent pr\u00e9senter des formes de pic d\u00e9form\u00e9es sur les phases stationnaires couramment utilis\u00e9es pour les m\u00e9thodes multi-r\u00e9sidus. C\u2019est pour cette raison que diff\u00e9rentes phases stationnaires et colonnes ont \u00e9t\u00e9 d\u00e9velopp\u00e9es afin de pouvoir effectuer l\u2019analyse de ces compos\u00e9s particuliers. La colonne \u00e9valu\u00e9e dans cette m\u00e9thode utilise une nouvelle phase stationnaire hybride combinant des interactions de types HILIC (Hydrophilic Interaction LIquid Chromatography) et \u00c9change Ionique. Les modes de r\u00e9tention d\u00e9pendent des conditions de phase mobile utilis\u00e9es et il est tr\u00e8s simple de passer d\u2019un mode \u00e0 l\u2019autre. Le but de cette \u00e9tude est r\u00e9sum\u00e9 dans les points suivants :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u00c9valuation des performances de la phase hybride dans diff\u00e9rentes dimensions de colonne pour l\u2019analyse de 10 compos\u00e9s anioniques.<\/li>\n\n\n\n<li>Validation de la m\u00e9thode en termes de sensibilit\u00e9, lin\u00e9arit\u00e9, et effets de matrice, dans quatre matrices diff\u00e9rentes : tomate, orange, oignon et coing.<\/li>\n\n\n\n<li>Am\u00e9lioration de la robustesse des temps de r\u00e9tention.<\/li>\n<\/ul>\n\n\n\n<p><strong>Note(s) :<\/strong>&nbsp;Cette \u00e9tude a \u00e9t\u00e9 r\u00e9alis\u00e9e \u00e0 l\u2019aide de colonnes Raptor Polar X.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Un laboratoire de r\u00e9f\u00e9rence europ\u00e9en (EURL) a \u00e9valu\u00e9 les colonnes LC Raptor Polar X pour la m\u00e9thode QuPPe Methanol extraction of polar pesticides without acidification&#8221;&#8221;<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[462],"tags":[],"industries-application":[2214,2216],"post-badge":[],"resource-type":[],"product-library":[2463,2445,2447],"resource-technique":[2318,2362],"ppma_author":[764,655],"class_list":["post-43771","post","type-post","status-publish","format-standard","hentry","category-articles-fr","industries-application-industrie-agroalimentaire","industries-application-securite-alimentaire","product-library-colonnes-lc","product-library-produits-pour-la-chromatographie-en-phase-liquide","product-library-produits-pour-la-preparation-dechantillons","resource-technique-chromatographie-en-phase-liquide","resource-technique-ms-ms-fr"],"acf":[],"taxonomy_info":{"category":[{"value":462,"label":"Articles"}],"industries-application":[{"value":2214,"label":"Industrie Agroalimentaire"},{"value":2216,"label":"S\u00e9curit\u00e9 alimentaire"}],"product-library":[{"value":2463,"label":"Colonnes LC"},{"value":2445,"label":"Produits pour la chromatographie en phase liquide"},{"value":2447,"label":"Produits pour la pr\u00e9paration d'\u00e9chantillons"}],"resource-technique":[{"value":2318,"label":"Chromatographie en phase liquide"},{"value":2362,"label":"MS\/MS"}]},"featured_image_src_large":false,"author_info":{"display_name":"Brenda Cogan","author_link":"https:\/\/discover.restek.com\/fr\/author\/brenda-coganrestek-com\/"},"comment_info":0,"category_info":[{"term_id":462,"name":"Articles","slug":"articles-fr","term_group":0,"term_taxonomy_id":462,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":462,"category_count":457,"category_description":"","cat_name":"Articles","category_nicename":"articles-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":764,"user_id":0,"is_guest":1,"slug":"victor-cutillas","display_name":"V\u00edctor Cutillas","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""},{"term_id":655,"user_id":0,"is_guest":1,"slug":"amadeo-r-fernandez-alba","display_name":"Amadeo R. Fern\u00e1ndez-Alba","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43771","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=43771"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43771\/revisions"}],"predecessor-version":[{"id":85741,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43771\/revisions\/85741"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=43771"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=43771"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=43771"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=43771"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=43771"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=43771"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=43771"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=43771"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=43771"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}