{"id":43808,"date":"2025-10-03T21:42:21","date_gmt":"2025-10-03T21:42:21","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/stabilwax-ms-thermally-stable-high-polarity-gc-columns\/"},"modified":"2026-01-03T15:53:44","modified_gmt":"2026-01-03T15:53:44","slug":"stabilwax-ms-thermally-stable-high-polarity-gc-columns","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/artikel\/gnss1818\/stabilwax-ms-thermally-stable-high-polarity-gc-columns","title":{"rendered":"Stabilwax-MS Thermally Stable, High-Polarity GC Columns"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>High-polarity, stable polyethylene glycol (PEG) stationary phase.<\/li>\n\n\n\n<li>Low bleed and rugged enough to withstand repeated temperature cycles without retention time shifting.<\/li>\n\n\n\n<li>Ideal for food, flavor, fragrance, and industrial<br>chemical and solvent analysis.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Stabilwax-MS Columns<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Stabilwax-MS Features<\/strong><\/td><td><strong>Your Benefit<\/strong><\/td><\/tr><tr><td>High thermal stability polyethylene glycol (PEG) stationary phase<\/td><td>Able to couple to MS detector Temperature range: 40 \u00b0C to 260 \u00b0C<\/td><\/tr><tr><td>Lower bleed than VF-WAXms<\/td><td>Lower detection limits<\/td><\/tr><tr><td>Ultra-clean, Restek-manufactured phase and bonding chemistries<\/td><td>Extraordinary inertness and stability against chemicals and high temperatures<\/td><\/tr><tr><td>Withstand repeated water injections with no phase loss or degradation<\/td><td>Longer column lifetime and solvent rinseable<\/td><\/tr><tr><td>Equivalent to USP G14, G15, G16, G20, and G39 phases<\/td><td>Ideal for polar analytes in foods, flavors, fragrances, industrial chemicals, and solvents<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Challenges of Polar Compound Analysis by GC<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">One of the most widely used columns in gas chromatography is a polyethylene glycol (PEG) or \u201cwax\u201d phase. This unique column is highly polar compared to nonpolar methyl phases like Rxi-1 columns (100% dimethyl polysiloxane) or Rxi-5 columns (5% diphenyl\/95% dimethyl polysiloxane) due to the presence of a polyethylene glycol backbone (Figure 1). The incorporation of the oxygen group in the backbone creates a phase with high selectivity for polar analytes, such as alcohols, glycols, esters, and ethers. These compound classes are commonly found in pharmaceutical raw materials, alcoholic beverages, industrial chemicals, flavors, and fragrances. A wax phase is capable of providing resolution of these compound classes that will not be achievable on nonpolar and intermediate polarity columns.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Due to phase structure, wax columns typically have lower maximum operating temperatures (240-250 \u00b0C) than nonpolar columns (e.g., max temp of an Rxi-5ms column is 360 \u00b0C) and exhibit higher column bleed levels than silicone phases. Because of this, retention time shifting can occur on some wax columns due to the loss of stationary phase (column bleed) that occurs during GC oven temperature cycling. Wax phases are also susceptible to oxygen contamination and can degrade quickly if exposed to oxygen from a leak in the GC at high temperatures. Oxygen contamination is chromatographically seen as a high column baseline that cannot be decreased by column conditioning or maintenance. A Restek electronic leak detector is the best way to ensure a leak-free system and long column lifetimes. See page 12 for details on this product and view the leak-checking demo on our website for how to properly use an electronic leak detector.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1: <\/strong>The highly polar nature of the Stabilwax-MS column makes it ideal for separating polar compounds found in food, flavors, fragrances, pharmaceutical raw materials, and industrial chemicals.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image43808_0136cc-0c .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image43808_0136cc-0c\"><figure class=\"aligncenter size-medium_large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"623\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnbr1818-01-768x623.jpg\" alt=\"\" class=\"kb-img wp-image-24166\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnbr1818-01-768x623.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnbr1818-01-300x243.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnbr1818-01.jpg 780w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Over the past several years, benchtop mass spectrometer (MS) detectors have become the GC detector of choice since they provide high sensitivity, quantitative retention time data, and compound identification. GC-MS users have long wanted thermally stable polar phases to use with their MS systems to take advantage of their unique selectivity without the worry of the column bleed seen on most wax columns.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Stabilwax-MS Columns: A Wax Phase Suitable for GC-MS<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The Stabilwax-MS column from Restek meets a GC-MS user\u2019s challenges. The polar deactivated surface tightly binds the polyethylene glycol polymer to the fused silica tubing, resulting in a high maximum operating temperature (260 \u00b0C). This allows for faster elution of higher molecular weight compounds since the column can be taken to high temperatures. In addition, low-bleed levels are ensured by strict quality testing that specifies maximum allowable bleed levels of 4.0 pA for 0.25 mm ID columns and 5.0 pA for 0.32 mm ID columns. When comparing actual bleed levels on a mass spectrometer, Stabilwax-MS columns outperform the VF-WAXms column (Figure 2). When tested at the 250 \u00b0C temperature limit of the VF-WAXms column, less bleed is seen on the Stabilwax-MS column.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The low-bleed level of the Stabilwax-MS column makes it suitable for GC-MS analysis of a wide range of polar compounds and matrices, including FAMEs, flavor compounds; essential oils; solvents; aromatics (including xylene isomers); acrolein\/acrylonitrile; and oxygenated compounds. The Stabilwax-MS column is also useful for purity testing of chemicals and analyzing impurities in water&nbsp;and alcoholic beverages. When methods require trace analysis, the highly polar, low-bleed Stabilwax-MS column produces excellent results compared to conventional wax columns. Review the applications in this brochure and try a low-bleed Stabilwax-MS column for yourself!<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:\u00a0<\/strong>Stabilwax-MS columns exhibit lower bleed levels than VF-WAXms columns and are stable up to 260 \u00b0C.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1165.png\" alt=\"Bleed Comparison: Stabilwax-MS vs. Competitor Wax MS at 250 \u00b0C\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1165<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-4 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,2-Dichlorobenzene-d4*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2199-69-1\/1,2-Dichlorobenzene-d4\" target=\"_blank\" rel=\"noopener\">1,2-Dichlorobenzene-d4*<\/a><\/td><td class=\"oth\">9.31<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">* Reference peak for MS response comparison<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Stabilwax-MS, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/10673?utm_source=chromatograms&amp;utm_medium=link&amp;utm_campaign=GC_GN1165\" rel=\"noopener\">cat.# 10673<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>1,2-Dichlorobenzene-d4 (<a target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/30049?utm_source=chromatograms&amp;utm_medium=link&amp;utm_campaign=GC_GN1165\" rel=\"noopener\">cat.# 30049<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Acetonitrile<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>2 \u00b5g\/mL<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L splitless (hold 0.50  min)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Premium 3.5 mm single taper w\/wool (<a target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23322?utm_source=chromatograms&amp;utm_medium=link&amp;utm_campaign=GC_GN1165\" rel=\"noopener\">cat.# 23322<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Purge Flow:<\/th><td>5 mL\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>40 &#176;C (hold 2 min) to 250 &#176;C at 15 &#176;C\/min (hold 5 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.0 mL\/min<tr><th class=\"sub conditions_header\" scope=\"row\">Linear Velocity:<\/th><td>36.1 cm\/sec @ 40 \u00b0C<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>Scan<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Scan Program:<\/th><td><\/td><\/tr><tr><td style=\"text-align:left\" colspan=\"2\"><table class=\"conditions_sim\"><thead><tr><th style=\"padding: 0 5px\">Group<\/th><th style=\"padding: 0 5px\">Start Time<br \/>(min)<\/th><th style=\"padding: 0 5px\">Scan Range<br \/>(amu)<\/th><th style=\"padding: 0 5px\">Scan Rate<br \/>(scans\/sec)<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>0.50<\/td><td>45-550<\/td><td>2<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>260 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Electron Energy:<\/th><td>70 eV<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Solvent Delay Time:<\/th><td>0.50  min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>PFTBA <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Shimadzu 2010 GC &amp; QP2010+ MS<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Competitor wax MS column dimensions = 30 m x 0.25 mm x 0.25 \u00b5m<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1165.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Fragrance Analysis<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Commercial Perfumes<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Materials containing fragrances, such as personal care products and perfumes, can be challenging to analyze by GC-MS due to their complex nature. Manufacturers analyze these difficult mixtures for quality control and stability purposes as well as during formulation. Because these mixtures contain a diverse range of compounds at varying concentrations, a stationary phase that offers good selectivity and excellent resolution for a wide range of analytes, high inertness, and low bleed for low-level analysis is necessary. The Stabilwax-MS column provides excellent separation of the alcohols, glycols, and terpenes in a commercial perfume sample analyzed by GC-MS in Figure 3.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:\u00a0<\/strong>Fragrance Allergens and Common Compounds in Commercial Perfume Separated on a Stabilwax-MS Column<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Commercial Perfume A<\/strong><\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1161.png\" alt=\"Fragrance Allergens and Common Compounds in Commercial Perfume on Stabilwax-MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1161<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethanol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/64-17-5\/Ethanol\" target=\"_blank\" rel=\"noopener\">Ethanol<\/a><\/td><td class=\"oth\">4.18<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Linalool*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78-70-6\/Linalool\" target=\"_blank\" rel=\"noopener\">Linalool*<\/a><\/td><td class=\"oth\">18.59<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Terpineol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/98-55-5\/Terpineol\" target=\"_blank\" rel=\"noopener\">Terpineol<\/a><\/td><td class=\"oth\">21.21<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzyl acetate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/140-11-4\/Benzyl acetate\" target=\"_blank\" rel=\"noopener\">Benzyl acetate<\/a><\/td><td class=\"oth\">21.78<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Citronellol*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-22-9\/Citronellol\" target=\"_blank\" rel=\"noopener\">Citronellol*<\/a><\/td><td class=\"oth\">22.29<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dipropylene glycol isomer 1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110-98-5\/Dipropylene glycol isomer 1\" target=\"_blank\" rel=\"noopener\">Dipropylene glycol isomer 1<\/a><\/td><td class=\"oth\">23.31<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Geraniol*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-24-1\/Geraniol\" target=\"_blank\" rel=\"noopener\">Geraniol*<\/a><\/td><td class=\"oth\">23.57<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dipropylene glycol isomer 2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110-98-5\/Dipropylene glycol isomer 2\" target=\"_blank\" rel=\"noopener\">Dipropylene glycol isomer 2<\/a><\/td><td class=\"oth\">24.10<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dipropylene glycol isomer 3\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110-98-5\/Dipropylene glycol isomer 3\" target=\"_blank\" rel=\"noopener\">Dipropylene glycol isomer 3<\/a><\/td><td class=\"oth\">24.20<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Lilial*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/80-54-6\/Lilial\" target=\"_blank\" rel=\"noopener\">Lilial*<\/a><\/td><td class=\"oth\">26.63<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isoeugenol*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/97-54-1\/Isoeugenol\" target=\"_blank\" rel=\"noopener\">Isoeugenol*<\/a><\/td><td class=\"oth\">28.29<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Piperonal\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-57-0\/Piperonal\" target=\"_blank\" rel=\"noopener\">Piperonal<\/a><\/td><td class=\"oth\">29.20<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diethyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/84-66-2\/Diethyl phthalate\" target=\"_blank\" rel=\"noopener\">Diethyl phthalate<\/a><\/td><td class=\"oth\">30.91<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzyl salicylate*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/118-58-1\/Benzyl salicylate\" target=\"_blank\" rel=\"noopener\">Benzyl salicylate*<\/a><\/td><td class=\"oth\">35.81<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">* Denotes fragrance allergen or suspected allergen <\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Stabilwax-MS, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/10673\" rel=\"noopener\">cat.# 10673<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Commercial perfume A<\/td><\/tr><tr><td><\/td><\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>  Neat<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 200:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Premium 3.5 mm ID single taper w\/wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23322\" rel=\"noopener\">cat.# 23322<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>35 &#176;C (hold 5 min) to 250 &#176;C at 7 &#176;C\/min (hold 5 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant linear velocity<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Linear Velocity:<\/th><td>36 cm\/sec<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>Scan<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Scan Program:<\/th><td><\/td><\/tr><tr><td style=\"text-align:left\" colspan=\"2\"><table class=\"conditions_sim\"><thead><tr><th style=\"padding: 0 5px\">Group<\/th><th style=\"padding: 0 5px\">Start Time<br \/>(min)<\/th><th style=\"padding: 0 5px\">Scan Range<br \/>(amu)<\/th><th style=\"padding: 0 5px\">Scan Rate<br \/>(scans\/sec)<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>0<\/td><td>40-550<\/td><td>2<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>260 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Electron Energy:<\/th><td>70 eV<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Solvent Delay Time:<\/th><td>0.5  min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Shimadzu 2010 GC &amp; QP2010+ MS<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>10673<\/li><li>23322<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>wax-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1161.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>Commercial Perfume B<\/strong><\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1162.png\" alt=\"Fragrance Allergens and Common Compounds in Commercial Perfume on Stabilwax-MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1162<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethanol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/64-17-5\/Ethanol\" target=\"_blank\" rel=\"noopener\">Ethanol<\/a><\/td><td class=\"oth\">4.18<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Limonene*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/138-86-3\/Limonene\" target=\"_blank\" rel=\"noopener\">Limonene*<\/a><\/td><td class=\"oth\">11.47<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Linalool*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78-70-6\/Linalool\" target=\"_blank\" rel=\"noopener\">Linalool*<\/a><\/td><td class=\"oth\">18.58<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Guaiene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3691-12-1\/Guaiene\" target=\"_blank\" rel=\"noopener\">Guaiene<\/a><\/td><td class=\"oth\">19.37<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Citronellol*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-22-9\/Citronellol\" target=\"_blank\" rel=\"noopener\">Citronellol*<\/a><\/td><td class=\"oth\">22.29<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Geraniol*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-24-1\/Geraniol\" target=\"_blank\" rel=\"noopener\">Geraniol*<\/a><\/td><td class=\"oth\">23.57<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dipropylene glycol isomer 1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110-98-5\/Dipropylene glycol isomer 1\" target=\"_blank\" rel=\"noopener\">Dipropylene glycol isomer 1<\/a><\/td><td class=\"oth\">24.11<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dipropylene glycol isomer 2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110-98-5\/Dipropylene glycol isomer 2\" target=\"_blank\" rel=\"noopener\">Dipropylene glycol isomer 2<\/a><\/td><td class=\"oth\">24.21<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Lilial*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/80-54-6\/Lilial\" target=\"_blank\" rel=\"noopener\">Lilial*<\/a><\/td><td class=\"oth\">26.61<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-Hexyl-cinnamaldehyde*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/101-86-0\/\u03b1-Hexyl-cinnamaldehyde\" target=\"_blank\" rel=\"noopener\">\u03b1-Hexyl-cinnamaldehyde*<\/a><\/td><td class=\"oth\">30.78<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzyl salicylate*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/118-58-1\/Benzyl salicylate\" target=\"_blank\" rel=\"noopener\">Benzyl salicylate*<\/a><\/td><td class=\"oth\">35.82<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">* Denotes fragrance allergen or suspected allergen; third isomer of dipropylene glycol not identified.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Stabilwax-MS, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/10673\" rel=\"noopener\">cat.# 10673<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Commercial perfume B<\/td><\/tr><tr><td><\/td><\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Neat<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 200:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Premium 3.5 mm single taper w\/wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23322\" rel=\"noopener\">cat.# 23322<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>35 &#176;C (hold 5 min) to 250 &#176;C at 7 &#176;C\/min (hold 5 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant linear velocity<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Linear Velocity:<\/th><td>36 cm\/sec<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>Scan<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Scan Program:<\/th><td><\/td><\/tr><tr><td style=\"text-align:left\" colspan=\"2\"><table class=\"conditions_sim\"><thead><tr><th style=\"padding: 0 5px\">Group<\/th><th style=\"padding: 0 5px\">Start Time<br \/>(min)<\/th><th style=\"padding: 0 5px\">Scan Range<br \/>(amu)<\/th><th style=\"padding: 0 5px\">Scan Rate<br \/>(scans\/sec)<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>0<\/td><td>40-550<\/td><td>2<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>260 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Electron Energy:<\/th><td>70 eV<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Solvent Delay Time:<\/th><td>0.5  min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Shimadzu 2010 GC &amp; QP2010+ MS<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>10673<\/li><li>23322<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>wax-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1162.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Flavor and Food Analysis<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Spearmint Oil<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Flavor and food samples contain numerous aromatic compounds; some are naturally present in the raw materials, and some form during processing. GC-MS is extensively used for the analysis of these compounds, which include esters, fatty acids, alcohols, aldehydes, and terpenes. It is also used to detect and measure contaminants from spoilage or adulteration that may be harmful to humans and, therefore, are often controlled by governmental agencies.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Spearmint oil is used in a variety of commercially available products, including food and personal care items. Companies manufacturing materials containing spearmint oil generally control quality by testing for carvone, the main active component that gives spearmint oil its minty flavor. Menthol is also often a target compound as it should be a minor component in spearmint oil but is commonly added as an adulterant. The large menthol peak shown in the spearmint oil sample in Figure 4 indicates that this sample is likely either spearmint oil with menthol added or a different type of oil (e.g., misbranded<br>peppermint oil). The Stabilwax-MS column provides the required selectivity to give excellent separation of this complex natural sample while exhibiting minimal column bleed at 250 \u00b0C by GC-MS.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4:\u00a0<\/strong>Commercial Spearmint Oil Analyzed on a Stabilwax-MS Column<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1169.png\" alt=\"Commercial Spearmint Oil on Stabilwax-MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1169<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-Pinene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/80-56-8\/\u03b1-Pinene\" target=\"_blank\" rel=\"noopener\">\u03b1-Pinene<\/a><\/td><td class=\"oth\">4.66<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b2-Pinene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/127-91-3\/\u03b2-Pinene\" target=\"_blank\" rel=\"noopener\">\u03b2-Pinene<\/a><\/td><td class=\"oth\">6.92<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Sabinene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3387-41-5\/Sabinene\" target=\"_blank\" rel=\"noopener\">Sabinene<\/a><\/td><td class=\"oth\">7.37<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Myrcene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/123-35-3\/Myrcene\" target=\"_blank\" rel=\"noopener\">Myrcene<\/a><\/td><td class=\"oth\">8.68<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Limonene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/138-86-3\/Limonene\" target=\"_blank\" rel=\"noopener\">Limonene<\/a><\/td><td class=\"oth\">9.49<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,8-Cineole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/470-82-6\/1,8-Cineole\" target=\"_blank\" rel=\"noopener\">1,8-Cineole<\/a><\/td><td class=\"oth\">9.67<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cymene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-87-6\/Cymene\" target=\"_blank\" rel=\"noopener\">Cymene<\/a><\/td><td class=\"oth\">11.33<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3-Octanol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/589-98-0\/3-Octanol\" target=\"_blank\" rel=\"noopener\">3-Octanol<\/a><\/td><td class=\"oth\">14.10<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Octen-3-ol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3391-86-4\/1-Octen-3-ol\" target=\"_blank\" rel=\"noopener\">1-Octen-3-ol<\/a><\/td><td class=\"oth\">15.26<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Menthone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/89-80-5\/Menthone\" target=\"_blank\" rel=\"noopener\">Menthone<\/a><\/td><td class=\"oth\">15.59<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Menthofuran\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/494-90-6\/Menthofuran\" target=\"_blank\" rel=\"noopener\">Menthofuran<\/a><\/td><td class=\"oth\">15.94<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b2-Bourbonene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5208-59-3\/\u03b2-Bourbonene\" target=\"_blank\" rel=\"noopener\">\u03b2-Bourbonene<\/a><\/td><td class=\"oth\">16.58<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Linalool\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78-70-6\/Linalool\" target=\"_blank\" rel=\"noopener\">Linalool<\/a><\/td><td class=\"oth\">17.11<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Menthyl acetate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/89-48-5\/Menthyl acetate\" target=\"_blank\" rel=\"noopener\">Menthyl acetate<\/a><\/td><td class=\"oth\">17.44<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Terpineol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/562-74-3\/4-Terpineol\" target=\"_blank\" rel=\"noopener\">4-Terpineol<\/a><\/td><td class=\"oth\">18.12<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dihydrocarvone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7764-50-3\/Dihydrocarvone\" target=\"_blank\" rel=\"noopener\">Dihydrocarvone<\/a><\/td><td class=\"oth\">18.26<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Neoisomenthol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/491-02-1\/Neoisomenthol\" target=\"_blank\" rel=\"noopener\">Neoisomenthol<\/a><\/td><td class=\"oth\">18.59<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Menthol*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1490-04-6\/Menthol\" target=\"_blank\" rel=\"noopener\">Menthol*<\/a><\/td><td class=\"oth\">18.88<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Terpineol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/98-55-5\/Terpineol\" target=\"_blank\" rel=\"noopener\">Terpineol<\/a><\/td><td class=\"oth\">19.76<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Germacrene D\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/23986-74-5\/Germacrene D\" target=\"_blank\" rel=\"noopener\">Germacrene D<\/a><\/td><td class=\"oth\">20.01<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Piperitone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/89-81-6\/Piperitone\" target=\"_blank\" rel=\"noopener\">Piperitone<\/a><\/td><td class=\"oth\">20.31<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carvone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-49-0\/Carvone\" target=\"_blank\" rel=\"noopener\">Carvone<\/a><\/td><td class=\"oth\">20.44<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Jasmone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/488-10-8\/Jasmone\" target=\"_blank\" rel=\"noopener\">Jasmone<\/a><\/td><td class=\"oth\">23.66<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Caryophyllene oxide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1139-30-6\/Caryophyllene oxide\" target=\"_blank\" rel=\"noopener\">Caryophyllene oxide<\/a><\/td><td class=\"oth\">24.28<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">* High signal suggests adulteration or misbranding.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Stabilwax-MS, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/10673\" rel=\"noopener\">cat.# 10673<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Commercial spearmint oil <\/td><\/tr><tr><td><\/td><\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>  Neat<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 150:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Premium 3.5 mm ID single taper w\/wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23322\" rel=\"noopener\">cat.# 23322<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>45 &#176;C (hold 5 min) to 250 &#176;C at 7 &#176;C\/min (hold 10 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant linear velocity<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Linear Velocity:<\/th><td>36 cm\/sec<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>Scan<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Scan Program:<\/th><td><\/td><\/tr><tr><td style=\"text-align:left\" colspan=\"2\"><table class=\"conditions_sim\"><thead><tr><th style=\"padding: 0 5px\">Group<\/th><th style=\"padding: 0 5px\">Start Time<br \/>(min)<\/th><th style=\"padding: 0 5px\">Scan Range<br \/>(amu)<\/th><th style=\"padding: 0 5px\">Scan Rate<br \/>(scans\/sec)<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>0<\/td><td>40-550<\/td><td>3.3<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>260 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Electron Energy:<\/th><td>70 eV<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Shimadzu 2010 GC &amp; QP2010+ MS<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>10673<\/li><li>23322<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>wax-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1169.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><em>Alcoholic Beverages<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Alcoholic beverages contain a wide range of volatile compounds, including alcohols and short-chain aldehydes, which manufacturers analyze for quality control, authenticity, and brand identification purposes. Gas chromatography can be used to determine these compounds since capillary columns offer efficient separations. Capillary GC is especially useful in the analysis of structurally similar compounds, such as fusel alcohols (i.e., isoamyl alcohol, 4-terpeniol, linalool, geraniol, etc.). The unique polarity of the Stabilwax-MS stationary phase ensures excellent resolution of a range of alcohols and fusel alcohols (also known as fusel oils) as shown in the analysis of a gin sample in Figure 5. The low bleed level obtained with a Stabilwax-MS column permits excellent response and quantitation of the gin volatiles to aid in accurate brand identification.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5:\u00a0<\/strong>Different brands of gin are compared using a Stabilwax-MS column.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1237.png\" alt=\"Two Brands of Gin on Stabilwax-MS (Overlay)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FF1237<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-Pinene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/80-56-8\/\u03b1-Pinene\" target=\"_blank\" rel=\"noopener\">\u03b1-Pinene<\/a><\/td><td class=\"oth\">6.16<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Beta-myrcene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/123-35-3\/Beta-myrcene\" target=\"_blank\" rel=\"noopener\">Beta-myrcene<\/a><\/td><td class=\"oth\">10.05<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for D-Limonene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5989-27-5\/D-Limonene\" target=\"_blank\" rel=\"noopener\">D-Limonene<\/a><\/td><td class=\"oth\">10.81<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isoamyl alcohol*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/123-51-3\/Isoamyl alcohol\" target=\"_blank\" rel=\"noopener\">Isoamyl alcohol*<\/a><\/td><td class=\"oth\">11.64<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b3-Terpinene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-85-4\/\u03b3-Terpinene\" target=\"_blank\" rel=\"noopener\">\u03b3-Terpinene<\/a><\/td><td class=\"oth\">12.08<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Camphor*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-22-2\/Camphor\" target=\"_blank\" rel=\"noopener\">Camphor*<\/a><\/td><td class=\"oth\">17.97<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Linalool\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78-70-6\/Linalool\" target=\"_blank\" rel=\"noopener\">Linalool<\/a><\/td><td class=\"oth\">18.56<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Terpineol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/562-74-3\/4-Terpineol\" target=\"_blank\" rel=\"noopener\">4-Terpineol<\/a><\/td><td class=\"oth\">19.56<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-Terpineol*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/98-55-5\/\u03b1-Terpineol\" target=\"_blank\" rel=\"noopener\">\u03b1-Terpineol*<\/a><\/td><td class=\"oth\">21.18<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nerol acetate*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/141-12-8\/Nerol acetate\" target=\"_blank\" rel=\"noopener\">Nerol acetate*<\/a><\/td><td class=\"oth\">22.14<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Geraniol*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-24-1\/Geraniol\" target=\"_blank\" rel=\"noopener\">Geraniol*<\/a><\/td><td class=\"oth\">23.55<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">* Not found in gin represented by red trace.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Stabilwax-MS, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/10673\" rel=\"noopener\">cat.# 10673<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Two different brands of gin<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>Neat <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 20:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Premium 3.5 mm Precision liner w\/wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23320\" rel=\"noopener\">cat.# 23320<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>35 &#176;C (hold 5 min) to 250 &#176;C at 7 &#176;C\/min (hold 5 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant linear velocity<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Linear Velocity:<\/th><td>36 cm\/sec<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>Scan<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Scan Program:<\/th><td><\/td><\/tr><tr><td style=\"text-align:left\" colspan=\"2\"><table class=\"conditions_sim\"><thead><tr><th style=\"padding: 0 5px\">Group<\/th><th style=\"padding: 0 5px\">Start Time<br \/>(min)<\/th><th style=\"padding: 0 5px\">Scan Range<br \/>(amu)<\/th><th style=\"padding: 0 5px\">Scan Rate<br \/>(scans\/sec)<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>0.5<\/td><td>40-550<\/td><td>2<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>260 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Solvent Delay Time:<\/th><td>0.5  min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Shimadzu 2010 GC &amp; QP2010+ MS<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>10673<\/li><li>23320<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>wax-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1237.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Industrial Chemicals Analysis<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Industrial chemicals and solvents are used in dry cleaning agents, paint thinners, spot removers, perfumes, inks, adhesives, and hundreds of other materials. Many also are used to manufacture polymers, fine chemicals, celluloid cements, and lacquers, such as wood stains and printing applications, as well as in the manufacture of coatings, pharmaceuticals, paints, and packaging material. Analysis of these chemicals and solvents is performed to monitor incoming purity, process control, and disposal (drum waste). Many of the compounds analyzed in Figure 6 are found in packaging samples and industrial hygiene samples. Figure 7 shows excellent separation of chemicals and solvents commonly identified in process control and purity samples. The thermal stability of the Stabilwax-MS column permits fast analysis times for a wide range of compounds in a temperature programmed run and results in low column bleed at 250 \u00b0C by GC-MS.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 6:\u00a0<\/strong>Excellent Resolution and Inertness of Alcohols and Acetates on a Stabilwax-MS Column<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1224.png\" alt=\"Alcohols and Acetates on Stabilwax-MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FF1224<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-4 col-12 peak-33\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(mg\/mL)<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for n-Hexane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110-54-3\/n-Hexane\" target=\"_blank\" rel=\"noopener\">n-Hexane<\/a><\/td><td class=\"oth\">1.59<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexane, 2-methyl-\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/591-76-4\/Hexane, 2-methyl-\" target=\"_blank\" rel=\"noopener\">Hexane, 2-methyl-<\/a><\/td><td class=\"oth\">1.72<\/td><td class=\"oth\">200<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentane, 2,3-dimethyl-\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/565-59-3\/Pentane, 2,3-dimethyl-\" target=\"_blank\" rel=\"noopener\">Pentane, 2,3-dimethyl-<\/a><\/td><td class=\"oth\">1.70<\/td><td class=\"oth\">200<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexane, 3-methyl-\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/589-34-4\/Hexane, 3-methyl-\" target=\"_blank\" rel=\"noopener\">Hexane, 3-methyl-<\/a><\/td><td class=\"oth\">1.72<\/td><td class=\"oth\">500<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Heptane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/142-82-5\/Heptane\" target=\"_blank\" rel=\"noopener\">Heptane<\/a><\/td><td class=\"oth\">1.79<\/td><td class=\"oth\">500<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/67-64-1\/Acetone\" target=\"_blank\" rel=\"noopener\">Acetone<\/a><\/td><td class=\"oth\">2.38<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethyl acetate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/141-78-6\/Ethyl acetate\" target=\"_blank\" rel=\"noopener\">Ethyl acetate<\/a><\/td><td class=\"oth\">3.16<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl alcohol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/67-56-1\/Methyl alcohol\" target=\"_blank\" rel=\"noopener\">Methyl alcohol<\/a><\/td><td class=\"oth\">3.26<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isopropyl acetate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-21-4\/Isopropyl acetate\" target=\"_blank\" rel=\"noopener\">Isopropyl acetate<\/a><\/td><td class=\"oth\">3.28<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Butanone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78-93-3\/2-Butanone\" target=\"_blank\" rel=\"noopener\">2-Butanone<\/a><\/td><td class=\"oth\">3.32<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-4 col-12 peak-33\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(mg\/mL)<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isopropyl alcohol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/67-63-0\/Isopropyl alcohol\" target=\"_blank\" rel=\"noopener\">Isopropyl alcohol<\/a><\/td><td class=\"oth\">3.84<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethanol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/64-17-5\/Ethanol\" target=\"_blank\" rel=\"noopener\">Ethanol<\/a><\/td><td class=\"oth\">3.96<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for n-Propyl acetate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/109-60-4\/n-Propyl acetate\" target=\"_blank\" rel=\"noopener\">n-Propyl acetate<\/a><\/td><td class=\"oth\">5.00<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl isobutyl ketone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-10-1\/Methyl isobutyl ketone\" target=\"_blank\" rel=\"noopener\">Methyl isobutyl ketone<\/a><\/td><td class=\"oth\">5.92<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Toluene*\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-88-3\/Toluene\" target=\"_blank\" rel=\"noopener\">Toluene*<\/a><\/td><td class=\"oth\">6.78<\/td><td class=\"oth\"><\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Propanol**\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/71-23-8\/1-Propanol\" target=\"_blank\" rel=\"noopener\">1-Propanol**<\/a><\/td><td class=\"oth\">6.90<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methacrylic acid, ethyl ester\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/97-63-2\/Methacrylic acid, ethyl ester\" target=\"_blank\" rel=\"noopener\">Methacrylic acid, ethyl ester<\/a><\/td><td class=\"oth\">7.18<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetic acid, butyl ester\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/123-86-4\/Acetic acid, butyl ester\" target=\"_blank\" rel=\"noopener\">Acetic acid, butyl ester<\/a><\/td><td class=\"oth\">7.92<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for p-Xylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-42-3\/p-Xylene\" target=\"_blank\" rel=\"noopener\">p-Xylene<\/a><\/td><td class=\"oth\">9.49<\/td><td class=\"oth\">800<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for m-Xylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-38-3\/m-Xylene\" target=\"_blank\" rel=\"noopener\">m-Xylene<\/a><\/td><td class=\"oth\">9.66<\/td><td class=\"oth\">300<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-4 col-12 peak-33\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(mg\/mL)<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzene, (1-methylethyl)-\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/98-82-8\/Benzene, (1-methylethyl)-\" target=\"_blank\" rel=\"noopener\">Benzene, (1-methylethyl)-<\/a><\/td><td class=\"oth\">10.55<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for o-Xylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-47-6\/o-Xylene\" target=\"_blank\" rel=\"noopener\">o-Xylene<\/a><\/td><td class=\"oth\">10.81<\/td><td class=\"oth\">300<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzene, propyl-\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/103-65-1\/Benzene, propyl-\" target=\"_blank\" rel=\"noopener\">Benzene, propyl-<\/a><\/td><td class=\"oth\">11.45<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethanol, 2-(1-methylethoxy)-\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/109-59-1\/Ethanol, 2-(1-methylethoxy)-\" target=\"_blank\" rel=\"noopener\">Ethanol, 2-(1-methylethoxy)-<\/a><\/td><td class=\"oth\">11.95<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for n-Butyl methacrylate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/97-88-1\/n-Butyl methacrylate\" target=\"_blank\" rel=\"noopener\">n-Butyl methacrylate<\/a><\/td><td class=\"oth\">11.99<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzene, tert-butyl-\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/98-06-6\/Benzene, tert-butyl-\" target=\"_blank\" rel=\"noopener\">Benzene, tert-butyl-<\/a><\/td><td class=\"oth\">12.15<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,3,5-Trimethylbenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-67-8\/1,3,5-Trimethylbenzene\" target=\"_blank\" rel=\"noopener\">1,3,5-Trimethylbenzene<\/a><\/td><td class=\"oth\">12.30<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzene, (1-methylpropyl)-\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/135-98-8\/Benzene, (1-methylpropyl)-\" target=\"_blank\" rel=\"noopener\">Benzene, (1-methylpropyl)-<\/a><\/td><td class=\"oth\">12.42<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">29.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzene, butyl-\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/104-51-8\/Benzene, butyl-\" target=\"_blank\" rel=\"noopener\">Benzene, butyl-<\/a><\/td><td class=\"oth\">13.90<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">30.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzene, 1,2,3-trimethyl-\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/526-73-8\/Benzene, 1,2,3-trimethyl-\" target=\"_blank\" rel=\"noopener\">Benzene, 1,2,3-trimethyl-<\/a><\/td><td class=\"oth\">14.40<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">31.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diacetone alcohol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/123-42-2\/Diacetone alcohol\" target=\"_blank\" rel=\"noopener\">Diacetone alcohol<\/a><\/td><td class=\"oth\">14.94<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<tr><td class=\"num\">32.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethanol, 2-butoxy-\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111-76-2\/Ethanol, 2-butoxy-\" target=\"_blank\" rel=\"noopener\">Ethanol, 2-butoxy-<\/a><\/td><td class=\"oth\">15.74<\/td><td class=\"oth\">1,400<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">*Toluene is the dilution solvent. **1-Propanol elutes with the toluene peak.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Stabilwax-MS, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/10673\" rel=\"noopener\">cat.# 10673<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Custom standard<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Toluene<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>  1-7 ng on-column (injection solution concentration given in peak list for each analyte)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 200:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Premium 3.5 mm single taper w\/wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23322\" rel=\"noopener\">cat.# 23322<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>35 &#176;C (hold 5.0 min) to 250 &#176;C at 7.0 &#176;C\/min (hold 5.0 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.0 mL\/min<tr><th class=\"sub conditions_header\" scope=\"row\">Linear Velocity:<\/th><td>36.1 cm\/sec @ 35 \u00b0C<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>Scan<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Scan Program:<\/th><td><\/td><\/tr><tr><td style=\"text-align:left\" colspan=\"2\"><table class=\"conditions_sim\"><thead><tr><th style=\"padding: 0 5px\">Group<\/th><th style=\"padding: 0 5px\">Start Time<br \/>(min)<\/th><th style=\"padding: 0 5px\">Scan Range<br \/>(amu)<\/th><th style=\"padding: 0 5px\">Scan Rate<br \/>(scans\/sec)<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>0.50<\/td><td>30-400<\/td><td><\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>260 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Electron Energy:<\/th><td>70 eV<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Solvent Delay Time:<\/th><td>0.50  min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>PFTBA <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Shimadzu 2010 GC &amp; QP2010+ MS<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>10673<\/li><li>23322<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>wax-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1224.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 7:\u00a0<\/strong>Analysis of Common Industrial Chemicals and Solvents on a Stabilwax-MS Column by GC-MS in Less Than 12 Min.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1163.png\" alt=\"Custom Solvents Mix on Stabilwax-MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1163<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethyl acetate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/141-78-6\/Ethyl acetate\" target=\"_blank\" rel=\"noopener\">Ethyl acetate<\/a><\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for n-Propyl acetate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/109-60-4\/n-Propyl acetate\" target=\"_blank\" rel=\"noopener\">n-Propyl acetate<\/a><\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for MEK\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78-93-3\/MEK\" target=\"_blank\" rel=\"noopener\">MEK<\/a><\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isopropyl alcohol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/67-63-0\/Isopropyl alcohol\" target=\"_blank\" rel=\"noopener\">Isopropyl alcohol<\/a><\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethanol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/64-17-5\/Ethanol\" target=\"_blank\" rel=\"noopener\">Ethanol<\/a><\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isopropyl acetate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-21-4\/Isopropyl acetate\" target=\"_blank\" rel=\"noopener\">Isopropyl acetate<\/a><\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Pentanone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/107-87-9\/2-Pentanone\" target=\"_blank\" rel=\"noopener\">2-Pentanone<\/a><\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for MIBK\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-10-1\/MIBK\" target=\"_blank\" rel=\"noopener\">MIBK<\/a><\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Propanol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/71-23-8\/1-Propanol\" target=\"_blank\" rel=\"noopener\">1-Propanol<\/a><\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Butyl acetate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/123-86-4\/Butyl acetate\" target=\"_blank\" rel=\"noopener\">Butyl acetate<\/a><\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Methoxy-2-propanol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/107-98-2\/1-Methoxy-2-propanol\" target=\"_blank\" rel=\"noopener\">1-Methoxy-2-propanol<\/a><\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for p-Xylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-42-3\/p-Xylene\" target=\"_blank\" rel=\"noopener\">p-Xylene<\/a><\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for m-Xylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-38-3\/m-Xylene\" target=\"_blank\" rel=\"noopener\">m-Xylene<\/a><\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propylene glycol ethyl ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1569-02-4\/Propylene glycol ethyl ether\" target=\"_blank\" rel=\"noopener\">Propylene glycol ethyl ether<\/a><\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for o-Xylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-47-6\/o-Xylene\" target=\"_blank\" rel=\"noopener\">o-Xylene<\/a><\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Methoxy-2-propyl acetate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-65-6\/1-Methoxy-2-propyl acetate\" target=\"_blank\" rel=\"noopener\">1-Methoxy-2-propyl acetate<\/a><\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cyclohexanone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-94-1\/Cyclohexanone\" target=\"_blank\" rel=\"noopener\">Cyclohexanone<\/a><\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethylene glycol monoethyl ether acetate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111-15-9\/Ethylene glycol monoethyl ether acetate\" target=\"_blank\" rel=\"noopener\">Ethylene glycol monoethyl ether acetate<\/a><\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diacetone alcohol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/123-42-2\/Diacetone alcohol\" target=\"_blank\" rel=\"noopener\">Diacetone alcohol<\/a><\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Stabilwax-MS, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/10673\" rel=\"noopener\">cat.# 10673<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Custom solvent standard<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Cyclohexane<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>400 ppm<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>0.5 \u00b5L split (split ratio 200:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Premium 4 mm Precision liner w\/wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23305\" rel=\"noopener\">cat.# 23305<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>200 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>40 &#176;C (hold 3 min) to 130 &#176;C at 8 &#176;C\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.0 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>Scan<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>200 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>200 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Quad Temp.:<\/th><td>150 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Electron Energy:<\/th><td>70 eV<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Solvent Delay Time:<\/th><td>2.5  min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>PFTBA <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890A GC &amp; 5975C MSD<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Scan Program: 30-150 amu <\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>10673<\/li><li>23305<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Stabilwax<\/li><li>Wax<\/li><li>glycol<\/li><li>glycols<\/li><li>solvents<\/li><li>wax-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1163.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Cleaning Solvent Analysis<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Cleaning solvents are used primarily to dissolve organic material. They clean without leaving residue, making them very useful in products, such as glass cleaners. The main criterion for cleaning solvents is water miscibility as the solvent must form a solution with the other water-soluble components. Thus, alcohols and glycols are popular choices. Glycol ethers are made from ethylene and propylene, and they prove to be excellent degreasers, cleaners, and intermediates. There are more than 30 different commonly used glycol ethers with varying technical properties and toxicity profiles. For example, diethylene glycol ethyl ether acetate (EGEEA) has been identified by the European Union as a reproductive toxin and is not manufactured or used in France. In fact, the use of glycol ethers is controlled or has been eliminated in many European countries. The Stabilwax-MS column has excellent selectivity and inertness for alcohols and glycol ethers found in cleaning solvents with the added advantage of good thermal stability. Figure 8 shows baseline resolution is achieved with a fast, 5-minute,temperature-programmed run to 220 \u00b0C. The thermal stability of the Stabilwax-MS column would allow a bakeout ramp to 250 \u00b0C to remove any high molecular weight contaminants in the cleaning solvents, which would prolong column lifetime and reduce column maintenance.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 8:\u00a0<\/strong>Cleaning Solvents Analyzed on a Stabilwax-MS Column<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1164.png\" alt=\"Custom Cleaning Solvents Standard on Stabilwax-MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1164<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-4 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Methoxy-ethanol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/109-86-4\/2-Methoxy-ethanol\" target=\"_blank\" rel=\"noopener\">2-Methoxy-ethanol<\/a><\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for BFB (IS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/460-00-4\/BFB\" target=\"_blank\" rel=\"noopener\">BFB (IS)<\/a><\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Butoxy ethanol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111-76-2\/2-Butoxy ethanol\" target=\"_blank\" rel=\"noopener\">2-Butoxy ethanol<\/a><\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Butoxyethyl acetate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/112-07-2\/2-Butoxyethyl acetate\" target=\"_blank\" rel=\"noopener\">2-Butoxyethyl acetate<\/a><\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diethylene glycol ethyl ether acetate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/112-15-2\/Diethylene glycol ethyl ether acetate\" target=\"_blank\" rel=\"noopener\">Diethylene glycol ethyl ether acetate<\/a><\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diethylene glycol butyl ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/112-34-5\/Diethylene glycol butyl ether\" target=\"_blank\" rel=\"noopener\">Diethylene glycol butyl ether<\/a><\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Stabilwax-MS, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/10673\" rel=\"noopener\">cat.# 10673<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Custom standard<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Methanol<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>200 ppm<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1.0 \u00b5L split (split ratio 300:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Premium 4 mm Precision liner w\/wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23305\" rel=\"noopener\">cat.# 23305<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>200 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>60 &#176;C to 220 &#176;C at 30 &#176;C\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.0 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>Scan<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Scan Program:<\/th><td><\/td><\/tr><tr><td style=\"text-align:left\" colspan=\"2\"><table class=\"conditions_sim\"><thead><tr><th style=\"padding: 0 5px\">Group<\/th><th style=\"padding: 0 5px\">Start Time<br \/>(min)<\/th><th style=\"padding: 0 5px\">Scan Range<br \/>(amu)<\/th><th style=\"padding: 0 5px\">Scan Rate<br \/>(scans\/sec)<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>2.3<\/td><td>30-200<\/td><td><\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>200 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>200 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Quad Temp.:<\/th><td>150 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Electron Energy:<\/th><td>70 eV<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Solvent Delay Time:<\/th><td>2.3  min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>PFTBA <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890A GC &amp; 5975C MSD<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>10673<\/li><li>23305<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Stabilwax<\/li><li>cleaning solvents<\/li><li>glycols<\/li><li>wax<\/li><li>wax-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1164.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Related Products<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/10673\">                                R\u00e9f. 10673                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Colonne capillaire Stabilwax-MS, L 30\u00a0m, DI 0.25\u00a0mm, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/10673\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23864\">                                R\u00e9f. 23864                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Septa Thermolite Plus, 11 mm (7\/16&quot;) avec CenterGuide, lot de 50<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23864\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21314\">                                R\u00e9f. 21314                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raccord pour d\u00e9tecteur MSD, pour GC Agilent avec GC-MS 5971\/5972, 5973, 5975 ou 5977<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21314\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21313\">                                R\u00e9f. 21313                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Joint plat pour raccord de conversion MSD, pour GC Agilent avec GC-MS 5971\/5972, 5973, 5975 ou 5977, lot de 2<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21313\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24819\">                                R\u00e9f. 24819                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Huile Inland 45 pour pompe primaire de MS, 1 litre<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24819\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23074\">                                R\u00e9f. 23074                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Multiplicateur d&#039;\u00e9lectrons ETP, pour GC-MS Agilent 5973 et 5975 (d\u00e9tecteur \u00e0 trois axes 5975C non compatible) (avec support pour premi\u00e8re installation)<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23074\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23075\">                                R\u00e9f. 23075                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Multiplicateur d&#039;\u00e9lectrons ETP, pour GC-MS Agilent 5973 et 5975 et LC-MSD (d\u00e9tecteur \u00e0 trois axes 5975C non compatible) (remplacement)<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23075\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27194\">                                R\u00e9f. 27194                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Kit de nettoyage pour GC-MS avec polisseuse \u00e9lectrique<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27194\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27195\">                                R\u00e9f. 27195                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Kit de nettoyage pour GC-MS<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27195\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27196\">                                R\u00e9f. 27196                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Kit de consommables de rechange, pour le nettoyage des GC-MS<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27196\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22685\">                                R\u00e9f. 22685                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Poudre d&#039;oxyde d&#039;aluminium pour nettoyage de GC-MS, 1kg<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22685\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22654\">                                R\u00e9f. 22654                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Pack &quot;Dynamic Duo&quot; (d\u00e9tecteur de fuites de gaz Restek et d\u00e9bitm\u00e8tre ProFLOW 6000)<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22654\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">                                R\u00e9f. 28500                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">D\u00e9tecteur \u00e9lectronique de fuites de gaz Restek<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22658\">                                R\u00e9f. 22658                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Embout pour acc\u00e8s difficiles pour d\u00e9tecteur \u00e9lectronique de fuites de gaz Restek<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22658\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22656\">                                R\u00e9f. 22656                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">D\u00e9bitm\u00e8tre \u00e9lectronique ProFLOW 6000 Restek<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22656\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22657\">                                R\u00e9f. 22657                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Etui souple optionnel<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22657\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28502\">                                R\u00e9f. 28502                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Kit de chargement pour d\u00e9tecteur \u00e9lectronique de fuites de gaz Restek (r\u00e9f. 28500)<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28502\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28501\">                                R\u00e9f. 28501                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">C\u00e2ble USB pour recharge de la batterie pour d\u00e9tecteur de fuites de gaz actuel uniquement (r\u00e9f. 28500)<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28501\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Thermally stable, high-polarity GC columns for flavor, food, fragrance, industrial chemical, and solvent analyses.<\/p>\n","protected":false},"author":11,"featured_media":7201,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[787],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2480,2492],"resource-technique":[2324,2328],"ppma_author":[414],"class_list":["post-43808","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-artikel","product-library-gaschromatographie-produkte","product-library-gc-saulen","resource-technique-gaschromatographie-gc","resource-technique-massenspektrometrie-ms"],"acf":[],"taxonomy_info":{"category":[{"value":787,"label":"Artikel"}],"product-library":[{"value":2480,"label":"Gaschromatographie Produkte"},{"value":2492,"label":"GC S\u00e4ulen"}],"resource-technique":[{"value":2324,"label":"Gaschromatographie (GC)"},{"value":2328,"label":"Massenspektrometrie (MS)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNBR1818-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":787,"name":"Artikel","slug":"artikel","term_group":0,"term_taxonomy_id":787,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":787,"category_count":510,"category_description":"","cat_name":"Artikel","category_nicename":"artikel","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43808","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=43808"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43808\/revisions"}],"predecessor-version":[{"id":79378,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43808\/revisions\/79378"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/7201"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=43808"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=43808"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=43808"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=43808"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=43808"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=43808"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=43808"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=43808"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=43808"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}