{"id":43816,"date":"2025-10-03T21:42:59","date_gmt":"2025-10-03T21:42:59","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/high-performing-restek-pal-spme-fibers\/"},"modified":"2026-08-11T15:19:06","modified_gmt":"2026-08-11T15:19:06","slug":"high-performing-restek-pal-spme-fibers","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/articles\/gnss2443\/high-performing-restek-pal-spme-fibers","title":{"rendered":"High-Performing Restek PAL SPME Fibers"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>Suitable for a wide range of analyte chemistries and sample matrices.<\/li>\n\n\n\n<li>Reliable performance meets or exceeds other brands.<\/li>\n\n\n\n<li>Optimized for PAL system autosamplers and compatible with most GC inlets.<\/li>\n\n\n\n<li>Smart SPME fibers now available.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Restek PAL SPME fibers deliver results that consistently meet or exceed the performance of other solid phase microextraction fibers. Our reliable SPME fibers are optimized for PAL system autosamplers and are compatible with most GC inlets. Restek PAL SPME fibers are ideal for many applications in environmental, food, clinical, and other industries.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Typical Applications<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Trace analysis in food<\/li>\n\n\n\n<li>Drugs and pharmaceuticals<\/li>\n\n\n\n<li>Herbicides\/pesticides<\/li>\n\n\n\n<li>Medical diagnostics<\/li>\n\n\n\n<li>Organics in water<\/li>\n\n\n\n<li>Trace impurities in polymers and solid samples<\/li>\n\n\n\n<li>Solvent residues in raw materials<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Which fiber is best for my application?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Restek PAL SPME fibers are suitable for a wide range of analyte chemistries and sample matrices. Choose the best SPME fiber for your application based on the properties of your target compounds. You can easily confirm the fiber type by the color of the hub that connects it to the injector.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\"><strong>Target Analytes<\/strong><\/td><td rowspan=\"2\"><strong>Molecular Weight<\/strong><\/td><td rowspan=\"2\"><strong>Recommended Fiber<\/strong><\/td><td rowspan=\"2\"><strong>Hub Color<\/strong><\/td><td colspan=\"3\"><strong>Non-Smart SPME Fiber<\/strong><\/td><td colspan=\"2\"><strong>Smart SPME Fiber<\/strong><\/td><\/tr><tr><td><strong>Each (cat.#)<\/strong><\/td><td><strong>3-pk. (cat.#)<\/strong><\/td><td><strong>5-pk. (cat.#)<\/strong><\/td><td><strong>Each (cat.#)<\/strong><\/td><td><strong>3-pk. (cat.#)<\/strong><\/td><\/tr><tr><td>Nonpolar<\/td><td>125\u2013600<\/td><td>7 \u03bcm polydimethylsiloxane<br>(PDMS)<\/td><td>Green<\/td><td><a href=\"https:\/\/www.restek.com\/p\/27482-1\" target=\"_blank\" rel=\"noopener\">27482-1<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/27482-3\" target=\"_blank\" rel=\"noopener\">27482-3<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/27482-5\" target=\"_blank\" rel=\"noopener\">27482-5<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/28919-1\" target=\"_blank\" rel=\"noopener\">28919-1<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/28919-3\" target=\"_blank\" rel=\"noopener\">28919-3<\/a><\/td><\/tr><tr><td>Nonpolar, semivolatile<\/td><td>80\u2013500<\/td><td>30 \u03bcm polydimethylsiloxane<br>(PDMS)<\/td><td>Golden<\/td><td><a href=\"https:\/\/www.restek.com\/p\/27481-1\" target=\"_blank\" rel=\"noopener\">27481-1<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/27481-3\" target=\"_blank\" rel=\"noopener\">27481-3<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/27481-5\" target=\"_blank\" rel=\"noopener\">27481-5<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/28918-1\" target=\"_blank\" rel=\"noopener\">28918-1<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/28918-3\" target=\"_blank\" rel=\"noopener\">28918-3<\/a><\/td><\/tr><tr><td>Volatile<\/td><td>60\u2013275<\/td><td>100 \u03bcm polydimethylsiloxane<br>(PDMS)<\/td><td>Red<\/td><td><a href=\"https:\/\/www.restek.com\/p\/27480-1\" target=\"_blank\" rel=\"noopener\">27480-1<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/27480-3\" target=\"_blank\" rel=\"noopener\">27480-3<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/27480-5\" target=\"_blank\" rel=\"noopener\">27480-5<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/28917-1\" target=\"_blank\" rel=\"noopener\">28917-1<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/28917-3\" target=\"_blank\" rel=\"noopener\">28917-3<\/a><\/td><\/tr><tr><td>Polar, semivolatile<\/td><td>80\u2013300<\/td><td>85 \u03bcm Polyacrylate<\/td><td>Gray<\/td><td><a href=\"https:\/\/www.restek.com\/p\/27478-1\" target=\"_blank\" rel=\"noopener\">27478-1<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/27478-3\" target=\"_blank\" rel=\"noopener\">27478-3<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/27478-5\" target=\"_blank\" rel=\"noopener\">27478-5<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/28913-1\" target=\"_blank\" rel=\"noopener\">28913-1<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/28913-3\" target=\"_blank\" rel=\"noopener\">28913-3<\/a><\/td><\/tr><tr><td>Highly volatile<\/td><td>30\u2013225<\/td><td>95 \u03bcm Carbon wide range\/Polydimethylsiloxane<br>(Carbon-WR\/PDMS)<\/td><td>Dark blue<\/td><td><a href=\"https:\/\/www.restek.com\/p\/27479-1\" target=\"_blank\" rel=\"noopener\">27479-1<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/27479-3\" target=\"_blank\" rel=\"noopener\">27479-3<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/27479-5\" target=\"_blank\" rel=\"noopener\">27479-5<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/28914-1\" target=\"_blank\" rel=\"noopener\">28914-1<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/28914-3\" target=\"_blank\" rel=\"noopener\">28914-3<\/a><\/td><\/tr><tr><td>Aromatic, semivolatile<\/td><td>50\u2013300<\/td><td>65 \u03bcm Divinylbenzene\/<br>Polydimethylsiloxane (DVB\/PDMS)<\/td><td>Violet<\/td><td><a href=\"https:\/\/www.restek.com\/p\/27874-1\" target=\"_blank\" rel=\"noopener\">27874-1<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/27874-3\" target=\"_blank\" rel=\"noopener\">27874-3<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/27874-5\" target=\"_blank\" rel=\"noopener\">27874-5<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/28916-1\" target=\"_blank\" rel=\"noopener\">28916-1<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/28916-3\" target=\"_blank\" rel=\"noopener\">28916-3<\/a><\/td><\/tr><tr><td>Volatile and semivolatile<\/td><td>40\u2013275<\/td><td>80 \u03bcm Divinylbenzene\/Carbon Wide Range\/<br>Polydimethylsiloxane (DVB\/Carbon-WR\/PDMS)<\/td><td>Dark Gray<\/td><td>\u2014<\/td><td><a href=\"https:\/\/www.restek.com\/p\/27873-3\" target=\"_blank\" rel=\"noopener\">27873-3<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/27873-5\" target=\"_blank\" rel=\"noopener\">27873-5<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/28915-1\" target=\"_blank\" rel=\"noopener\">28915-1<\/a><\/td><td><a href=\"https:\/\/www.restek.com\/p\/28915-3\" target=\"_blank\" rel=\"noopener\">28915-3<\/a><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Restek PAL SPME Fibers Are Proven to Perform<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A quantitative comparison of Restek PAL SPME fibers to a popular brand proves that Restek PAL SPME fibers perform as well as or better than the competition. In this comparison of 80 \u03bcm DVB\/Carbon WR\/PDMS triple-phase fibers, it is clear that comparable results were obtained for residual solvents in cannabis extracts.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Residual solvents analysis in cannabis extracts may be analyzed with a USP &lt;467&gt; approach. The data below were obtained by headspace (HS)\u2013solid phase microextraction (SPME) on a 6 mL sample prepared as follows:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>3 g sodium chloride (NaCl) was measured into a 20 mL amber headspace vial (cat. # 23086) with a screw-top cap (cat. # 23090).<\/li>\n\n\n\n<li>6 mL of deionized (DI) water was then added to the vial.<\/li>\n\n\n\n<li>Residual solvents (cat.# 34105) standard and <em>n<\/em>-propane, isobutane, <em>n<\/em>-butane (Emerald Scientific) standards were spiked at 10 \u03bcg\/mL.<\/li>\n\n\n\n<li>Everything was capped and vortexed at 3000 rpm for 10 seconds, inverted, and then vortexed again for 10 seconds at 3000 rpm.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">This sample was analyzed via the following parameters:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Test Parameters<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>SPME Fibers: 80 \u03bcm DVB\/Carbon WR\/PDMS<\/li>\n\n\n\n<li>Extraction: 2 min in headspace at 30 \u00b0C with 1000 rpm agitation<\/li>\n\n\n\n<li>Thermal Desorption: 10 sec at 250 \u00b0C<\/li>\n\n\n\n<li>Column: Rxi-624 Sil MS, 30 m x 0.25 mm x 1.40 \u03bcm (cat. # 13868)<\/li>\n\n\n\n<li>Oven Program: 30 \u00b0C (hold 3 min) to 85 \u00b0C (hold 2 min) at 15 \u00b0C\/min to 250 \u00b0C at 35 \u00b0C\/min<\/li>\n\n\n\n<li>Autosampler: PAL CTC RTC<\/li>\n\n\n\n<li>GC-MS: 7890 with 5977B HES MS<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Restek PAL SPME fibers meet or exceed the performance of other brands residual solvents in cannabis extracts.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"360\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2443E-UNV-1024x360.jpg\" alt=\"\" class=\"wp-image-23056\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2443E-UNV-1024x360.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2443E-UNV-300x105.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2443E-UNV-768x270.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2443E-UNV-1536x540.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2443E-UNV.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">High-Performing SPME Fibers from Restek<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">PAL SPME fibers are high-performing fibers that meet or exceed the performance of other brands. Our reliable SPME fibers are optimized for PAL system autosamplers and are compatible with most GC inlets. SPME fibers are suitable for a wide range of analyte chemistries and sample matrices.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>PAL system compatibility:<\/strong> Non-smart SPME fibers are not compatible with PAL3 series II rails. Smart SPME Fibers are compatible with PAL3 Series I and newer. Check instrument manufacturer requirements. Check instrument manufacturer requirements.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Recommended maximum GC inlet pressure is 50 psi or less.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">All PAL SPME fibers are 10 mm in length and are housed in a 23-gauge needle. The phase is bonded onto a fused silica fiber core.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Our product line is continually expanding! Find rugged SPME Arrows and see what\u2019s new at <a href=\"https:\/\/www.restek.com\/SPME\" target=\"_blank\" rel=\"noopener\">www.restek.com\/SPME<\/a><\/h3>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Related Products<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27490\">                                R\u00e9f. 27490                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Support complet pour fibres SPME PAL pour injection manuelle<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27490\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31015\">                                R\u00e9f. 31015                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">M\u00e9lange-test de contr\u00f4le des performances pour SPME, 1\u00a0\u00b5g:ml, eau\/m\u00e9thanol (99:1), ampoule de 1\u00a0ml, lot de 3<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31015\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28912\">                                R\u00e9f. 28912                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Kit d&#039;injection manuelle PAL Smart SPME Arrow\/Fibre<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28912\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Restek PAL SPME fibers are high-performing fibers that meet or exceed the performance of other brands. Our reliable SPME fibers are optimized for PAL system autosamplers and are compatible with most GC inlets. SPME fibers are suitable for a wide range of analyte chemistries and sample matrices.<\/p>\n","protected":false},"author":11,"featured_media":7381,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[7],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[567],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-43816","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles","resource-type-selection-guides"],"acf":[],"taxonomy_info":{"category":[{"value":7,"label":"Articles"}],"resource-type":[{"value":567,"label":"Selection Guides"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNSS2443-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":7,"category_count":510,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43816","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=43816"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43816\/revisions"}],"predecessor-version":[{"id":87167,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43816\/revisions\/87167"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/7381"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=43816"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=43816"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=43816"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=43816"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=43816"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=43816"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=43816"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=43816"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=43816"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}