{"id":43828,"date":"2020-10-07T14:30:00","date_gmt":"2020-10-07T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/tubes-et-accessoires-radiello-pour-lechantillonnage-dair-passif\/"},"modified":"2026-01-28T21:53:53","modified_gmt":"2026-01-28T21:53:53","slug":"tubes-et-accessoires-radiello-pour-lechantillonnage-dair-passif","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/articles-fr\/gnss2960-fr\/tubes-et-accessoires-radiello-pour-lechantillonnage-dair-passif","title":{"rendered":"Tubes et accessoires radiello pour l\u2019\u00e9chantillonnage d\u2019air passif"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>Technologie radiale 3D pour des performances sup\u00e9rieures aux \u00e9chantillonneurs axiaux 2D.<\/li>\n\n\n\n<li>Excellente d\u00e9tection des faibles concentrations m\u00eame lors d\u2019\u00e9chantillonnages de courte dur\u00e9e.<\/li>\n\n\n\n<li>Une grande capacit\u00e9 pour des pr\u00e9l\u00e8vements longue dur\u00e9e fiables.<\/li>\n\n\n\n<li>\u00c9chantillonnage passif : plus besoin de pompes !<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Les tubes pour pr\u00e9l\u00e8vement d\u2019air passif par diffusion radiello sont d\u00e9sormais distribu\u00e9s par Restek. Ces tubes font appel \u00e0 une technologie radiale 3D pr\u00e9sentant de nombreux avantages par rapport aux \u00e9chantillonneurs conventionnels axiaux plats 2D. Les tubes radiello constituent une solution alternative de pr\u00e9l\u00e8vement fiable et \u00e9conomique. Ils offrent une grande sensibilit\u00e9 permettant la d\u00e9tection de faibles concentrations m\u00eame avec des pr\u00e9l\u00e8vements courts. Leur grande capacit\u00e9 autorise des pr\u00e9l\u00e8vements de longue dur\u00e9e donc des r\u00e9sultats plus fiables. Il existe une large gamme de tubes radiello adapt\u00e9s \u00e0 diverses familles de compos\u00e9s chimiques. Il est ainsi possible de choisir le tube radiello contenant l\u2019adsorbant id\u00e9al pour une application donn\u00e9e.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">En quoi le tube radiello se d\u00e9marque-t-il des tubes conventionnels ?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Les tubes radiello se caract\u00e9risent par une conception cylindrique coaxiale 3D unique. Ce syst\u00e8me pr\u00e9sente une grande surface de diffusion situ\u00e9e \u00e0 une distance fixe et uniforme d\u2019une colonne d\u2019absorbant centrale. L\u2019air p\u00e9n\u00e8tre ainsi de tous les c\u00f4t\u00e9s et les analytes sont pi\u00e9g\u00e9s sur cette surface adsorbante interne. Il en r\u00e9sulte une vitesse d\u2019\u00e9chantillonnage plus importante et une capacit\u00e9 plus grande par rapport aux \u00e9chantillonneurs conventionnels axiaux plats 2D.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\">Les avantages du syst\u00e8me radiello<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-image\">\n<figure class=\"alignright size-full is-resized\" style=\"margin-top:10px;margin-right:20px;margin-bottom:10px;margin-left:20px\"><img loading=\"lazy\" decoding=\"async\" width=\"700\" height=\"763\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2960-01.jpg\" alt=\"\" class=\"wp-image-23256\" style=\"width:491px;height:auto\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2960-01.jpg 700w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2960-01-275x300.jpg 275w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/figure>\n<\/div>\n\n\n<ul class=\"wp-block-list\">\n<li>La grande vitesse d\u2019\u00e9chantillonnage garantit une sensibilit\u00e9 de l\u2019ordre de la ppbv m\u00eame avec des dur\u00e9es de pr\u00e9l\u00e8vement courtes.<\/li>\n\n\n\n<li>Grande capacit\u00e9 pour des pr\u00e9l\u00e8vements de longue dur\u00e9e fiables.<\/li>\n\n\n\n<li>\u00c9chantillonnage passif : plus besoin de pompes !<\/li>\n\n\n\n<li>Efficacit\u00e9 ind\u00e9pendante de la vitesse d\u2019entr\u00e9e d\u2019air.<\/li>\n<\/ul>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Pourquoi utiliser les tubes radiello ?<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Leur conception radiale 3D fait que la vitesse d\u2018entr\u00e9e d\u2019air n\u2019a pas d\u2019effet sur leur efficacit\u00e9. Elle autorise aussi un \u00e9chantillonnage plus rapide.<\/li>\n\n\n\n<li>La grande vitesse d\u2019\u00e9chantillonnage garantit une excellente sensibilit\u00e9 m\u00eame avec des dur\u00e9es d\u2019\u00e9chantillonnage courtes (jusqu\u2019\u00e0 15 minutes).<\/li>\n\n\n\n<li>Leur grande capacit\u00e9 d\u2019adsorption permet des pr\u00e9l\u00e8vements de longue dur\u00e9e (jusqu\u2019\u00e0 30 jours) sans \u00ab per\u00e7age \u00bb et limite le risque de r\u00e9trodiffusion.<\/li>\n\n\n\n<li>Propos\u00e9s avec un large choix d\u2019adsorbants, ils peuvent \u00eatre utilis\u00e9s pour de nombreuses applications dans les domaines les plus vari\u00e9s tels que l\u2019analyse environnementale, l\u2019analyse de l\u2019air dans l\u2019habitat, les contr\u00f4les d\u2019hygi\u00e8ne industrielle et sur poste de travail.<\/li>\n\n\n\n<li>La d\u00e9sorption se fait soit thermiquement soit par solvant.<\/li>\n\n\n\n<li>Une large gamme d\u2019accessoires est disponible avec notamment des supports diffusifs protecteurs imperm\u00e9ables et des portoirs r\u00e9utilisables.<\/li>\n\n\n\n<li>Ils sont tr\u00e8s faciles \u00e0 utiliser. Plus besoin de pompes !<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>De par leur conception radiale 3D, la vitesse d\u2019entr\u00e9e d\u2019air n\u2019a pas d\u2019effet sur l\u2019efficacit\u00e9 des tubes radiello. L\u2019\u00e9chantillonnage est bien plus rapide par rapport aux tubes conventionnels 2D.<\/strong><\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Compos\u00e9<\/strong><\/th><th><strong>Tube 3D radial radiello<br>Vitesse d\u2019\u00e9chantillonnage (ml\/min)<\/strong><\/th><th><strong>Tube 2D axial conventionnel<br>Vitesse d\u2019\u00e9chantillonnage (ml\/min)<\/strong><\/th><\/tr><\/thead><tbody><tr><td>M\u00e9thanol<\/td><td>125<\/td><td>NS<\/td><\/tr><tr><td>\u00c9thanol<\/td><td>102<\/td><td>44<\/td><\/tr><tr><td>Ac\u00e9tone<\/td><td>77<\/td><td>40<\/td><\/tr><tr><td>Benz\u00e8ne<\/td><td>80<\/td><td>36<\/td><\/tr><tr><td>M\u00e9thyl \u00e9thyl c\u00e9tone<\/td><td>79<\/td><td>36<\/td><\/tr><tr><td>Tolu\u00e8ne<\/td><td>74<\/td><td>31<\/td><\/tr><tr><td>\u00c9thylbenz\u00e8ne<\/td><td>68<\/td><td>27<\/td><\/tr><tr><td><em>n<\/em>-Octane<\/td><td>53<\/td><td>27<\/td><\/tr><tr><td>Naphthal\u00e8ne<\/td><td>25<\/td><td>25<\/td><\/tr><tr><td colspan=\"3\">NS \u2013 Non adapt\u00e9<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">La grande vitesse d\u2019\u00e9chantillonnage garantit une excellente sensibilit\u00e9 m\u00eame avec des dur\u00e9es de pr\u00e9l\u00e8vement courtes<\/h3>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\">Les avantages des tubes radiello<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Meilleure r\u00e9ponse pour tous les compos\u00e9s par rapport aux tubes axiaux conventionnels.<\/li>\n\n\n\n<li>Une augmentation moyenne de 163% de la r\u00e9ponse pour les 8 compos\u00e9s ci-dessous.<\/li>\n\n\n\n<li>Excellente reproductibilit\u00e9 avec une variation moyenne de 5,6%<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"466\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-GNSS2960-02-1024x466.jpg\" alt=\"\" class=\"wp-image-23262\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2960-02-1024x466.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2960-02-300x137.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2960-02-768x350.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2960-02-1536x700.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2960-02.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Les tubes radiello ont une capacit\u00e9 plus grande que les tubes ou badges axiaux conventionnels. Ils garantissent ainsi des r\u00e9sultats fiables m\u00eame avec des dur\u00e9es d\u2019\u00e9chantillonnage longues sans perte d\u2019\u00e9chantillon par &#8220;per\u00e7age&#8221; et un risque moindre de r\u00e9trodiffusion<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Lors d\u2019un \u00e9chantillonnage &#8220;actif&#8221; \u00e0 l\u2019aide d\u2019une pompe, le ph\u00e9nom\u00e8ne de &#8220;per\u00e7age&#8221; se produit lorsqu\u2019une partie de l\u2018analyte pr\u00e9lev\u00e9 traverse le lit d\u2019adsorbant. Si la concentration de l\u2019analyte dans l\u2019air sortant est sup\u00e9rieure \u00e0 10% de la concentration dans l\u2019air \u00e9chantillonn\u00e9, la poursuite du pompage entra\u00eene une perte d\u2019analyte et un calcul erron\u00e9 de sa r\u00e9elle concentration dans l\u2019air ambiant. Il en est de m\u00eame dans le cas d\u2019une r\u00e9trodiffusion lorsque l\u2019adsorbant ne retient pas suffisamment l\u2019analyte pr\u00e9lev\u00e9. Bien qu\u2019une r\u00e9trodiffusion reste possible avec les tubes radiello, leur grande capacit\u00e9 d\u2019adsorption autorise des prises d\u2019\u00e9chantillon bien plus importantes avant que celle-ci ne soit observ\u00e9e.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pour r\u00e9aliser la comparaison ci-dessous, le benz\u00e8ne est pi\u00e9g\u00e9 par pompage sur du charbon actif et parall\u00e8lement \u00e9chantillonn\u00e9 par diffusion avec un tube radiello 130 (dans les deux cas \u00e0 25\u00b0C). Avec le charbon actif mettant en oeuvre un pompage, le \u00ab per\u00e7age \u00bb se produit \u00e0 des volumes de 35, 44 et 49 litres lorsque la concentration en benz\u00e8ne est respectivement de 100, 50 et 10\u03bcg\/m3. A ces m\u00eames concentrations, le tube radiello autorise des volumes de 1600, 2300 et 3050 litres avant qu\u2019une r\u00e9trodiffusion ne soit d\u00e9tect\u00e9e.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"599\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-GNSS2960-03-1024x599.jpg\" alt=\"\" class=\"wp-image-23268\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2960-03-1024x599.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2960-03-300x176.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2960-03-768x449.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2960-03-1536x899.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2960-03.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Exemple d\u2019application : radiello 145<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le tube radiello 145 (RAD145) est sp\u00e9cialement con\u00e7u pour l\u2019analyse des compos\u00e9s volatils (COV) dans l\u2019air. Sa conception radiale 3D permet des vitesses d\u2019\u00e9chantillonnage bien plus \u00e9lev\u00e9es et offre une plus grande capacit\u00e9 que les \u00e9chantillonneurs axiaux 2D plats. Des vitesses d\u2019\u00e9chantillonnage plus grandes signifient que des COV au stade de la ppbv peuvent \u00eatre d\u00e9tect\u00e9s moyennant des dur\u00e9es d\u2019\u00e9chantillonnage tr\u00e8s courtes.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\">Pr\u00e9l\u00e8vement de 4 heures avec un tube radiello 145 dans un centre d\u2019exp\u00e9dition<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ar1171.png\" alt=\"4-Hr Shipping Facility Air Sample with radiello 145\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_AR1171<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/115-07-1\/Propene\" target=\"_blank\" rel=\"noopener\">Propene<\/a><\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Methyl-1-propene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/115-11-7\/2-Methyl-1-propene\" target=\"_blank\" rel=\"noopener\">2-Methyl-1-propene<\/a><\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetaldehyde\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/75-07-0\/Acetaldehyde\" target=\"_blank\" rel=\"noopener\">Acetaldehyde<\/a><\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Methylbutane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78-78-4\/2-Methylbutane\" target=\"_blank\" rel=\"noopener\">2-Methylbutane<\/a><\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/109-66-0\/Pentane\" target=\"_blank\" rel=\"noopener\">Pentane<\/a><\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Furan\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110-00-9\/Furan\" target=\"_blank\" rel=\"noopener\">Furan<\/a><\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methylene chloride\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/75-09-2\/Methylene chloride\" target=\"_blank\" rel=\"noopener\">Methylene chloride<\/a><\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110-54-3\/Hexane\" target=\"_blank\" rel=\"noopener\">Hexane<\/a><\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetonitrile\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/75-05-8\/Acetonitrile\" target=\"_blank\" rel=\"noopener\">Acetonitrile<\/a><\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/71-43-2\/Benzene\" target=\"_blank\" rel=\"noopener\">Benzene<\/a><\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Toluene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-88-3\/Toluene\" target=\"_blank\" rel=\"noopener\">Toluene<\/a><\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-90-7\/Chlorobenzene\" target=\"_blank\" rel=\"noopener\">Chlorobenzene<\/a><\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rtx-VMS, 60 m, 0.25 mm ID, 1.40 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/19916\" rel=\"noopener\">cat.# 19916<\/a>)<\/td><\/tr><tr><td><\/td><td>with MXT low-dead-volume connector (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/20536\" rel=\"noopener\">cat.# 20536<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Shipping facility air sample<\/td><\/tr>\n<tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td>on-column<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>40 &#176;C (hold 7 min) to 250 &#176;C at 30 &#176;C\/min (hold 2 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>2.0 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>Scan<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Scan Program:<\/th><td><\/td><\/tr><tr><td style=\"text-align:left\" colspan=\"2\"><table class=\"conditions_sim\"><thead><tr><th style=\"padding: 0 5px\">Group<\/th><th style=\"padding: 0 5px\">Start Time<br \/>(min)<\/th><th style=\"padding: 0 5px\">Scan Range<br \/>(amu)<\/th><th style=\"padding: 0 5px\">Scan Rate<br \/>(scans\/sec)<\/th><\/tr><\/thead><tbody><tr><td>2<\/td><td>8.80<\/td><td>38<\/td><td>226<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Type:<\/th><td>Extractor <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Extractor Lens:<\/th><td>6 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>230 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Quad Temp.:<\/th><td>150 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Electron Energy:<\/th><td>70 eV<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>BFB <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Preconcentrator<\/th><td>Markes Unity<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">&nbsp;&nbsp;Trap 1 Settings<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">&nbsp;&nbsp;Type\/Sorbent :<\/th><td>radiello 145 <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">&nbsp;&nbsp;Desorb temp.:<\/th><td>350 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">&nbsp;&nbsp;Desorb flow:<\/th><td>50 mL\/min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">&nbsp;&nbsp;Desorb time:<\/th><td>300 sec<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">&nbsp;&nbsp;Trap 2 Settings<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">&nbsp;&nbsp;Type\/Sorbent:<\/th><td>Air Toxics <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">&nbsp;&nbsp;Cooling temp.:<\/th><td>30 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">&nbsp;&nbsp;Desorb temp.:<\/th><td>310 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">&nbsp;&nbsp;Desorb time:<\/th><td>3 sec<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890B GC &amp; 5977A MSD<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>The radiello 145 passive air sampler (RAD145) utilizes a stainless steel net cartridge packed with 350 mg of graphitized charcoal (Carbograph 4). Airborne volatile organic compounds (VOCs) were adsorbed to the charcoal and then thermally desorbed and analyzed by GC-MS.<br \/><br \/>Trap 1 conditions were used for radiello desorption. Trap 2 conditions were used for Unity desorption.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>19916<\/li><li>20536<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ar1171.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ar1170.png\" alt=\"16-Hr Laboratory Air Sample with radiello 145\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_AR1170<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-4 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/115-07-1\/Propene\" target=\"_blank\" rel=\"noopener\">Propene<\/a><\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Methyl-1-propene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/115-11-7\/2-Methyl-1-propene\" target=\"_blank\" rel=\"noopener\">2-Methyl-1-propene<\/a><\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetaldehyde\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/75-07-0\/Acetaldehyde\" target=\"_blank\" rel=\"noopener\">Acetaldehyde<\/a><\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/67-64-1\/Acetone\" target=\"_blank\" rel=\"noopener\">Acetone<\/a><\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110-54-3\/Hexane\" target=\"_blank\" rel=\"noopener\">Hexane<\/a><\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Butanal\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/123-72-8\/Butanal\" target=\"_blank\" rel=\"noopener\">Butanal<\/a><\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetic acid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/64-19-7\/Acetic acid\" target=\"_blank\" rel=\"noopener\">Acetic acid<\/a><\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Toluene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-88-3\/Toluene\" target=\"_blank\" rel=\"noopener\">Toluene<\/a><\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for D-Limonene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5989-27-5\/D-Limonene\" target=\"_blank\" rel=\"noopener\">D-Limonene<\/a><\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzaldehyde\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-52-7\/Benzaldehyde\" target=\"_blank\" rel=\"noopener\">Benzaldehyde<\/a><\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rtx-VMS, 60 m, 0.25 mm ID, 1.40 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/19916\" rel=\"noopener\">cat.# 19916<\/a>)<\/td><\/tr><tr><td><\/td><td>with MXT low-dead-volume connector (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/20536\" rel=\"noopener\">cat.# 20536<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Laboratory air sample<\/td><\/tr>\n<tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td>on-column<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>40 &#176;C (hold 7 min) to 250 &#176;C at 30 &#176;C\/min (hold 2 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>2.0 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>Scan<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Scan Program:<\/th><td><\/td><\/tr><tr><td style=\"text-align:left\" colspan=\"2\"><table class=\"conditions_sim\"><thead><tr><th style=\"padding: 0 5px\">Group<\/th><th style=\"padding: 0 5px\">Start Time<br \/>(min)<\/th><th style=\"padding: 0 5px\">Scan Range<br \/>(amu)<\/th><th style=\"padding: 0 5px\">Scan Rate<br \/>(scans\/sec)<\/th><\/tr><\/thead><tbody><tr><td>2<\/td><td>8.80<\/td><td>38<\/td><td>226<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Type:<\/th><td>Extractor <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Extractor Lens:<\/th><td>6 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>230 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Quad Temp.:<\/th><td>150 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Electron Energy:<\/th><td>70 eV<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>BFB <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Preconcentrator<\/th><td>Markes Unity<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">&nbsp;&nbsp;Trap 1 Settings<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">&nbsp;&nbsp;Type\/Sorbent :<\/th><td>radiello 145 <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">&nbsp;&nbsp;Desorb temp.:<\/th><td>350 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">&nbsp;&nbsp;Desorb flow:<\/th><td>50 mL\/min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">&nbsp;&nbsp;Desorb time:<\/th><td>300 sec<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">&nbsp;&nbsp;Trap 2 Settings<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">&nbsp;&nbsp;Type\/Sorbent:<\/th><td>Air Toxics <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">&nbsp;&nbsp;Cooling temp.:<\/th><td>30 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">&nbsp;&nbsp;Desorb temp.:<\/th><td>310 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">&nbsp;&nbsp;Desorb time:<\/th><td>3 sec<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890B GC &amp; 5977A MSD<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>The radiello 145 passive air sampler (RAD145) utilizes a stainless steel net cartridge packed with 350 mg of graphitized charcoal (Carbograph 4). Airborne volatile organic compounds (VOCs) were adsorbed to the charcoal and then thermally desorbed and analyzed by GC-MS.<br \/><br \/>Trap 1 conditions were used for radiello desorption. Trap 2 conditions were used for Unity desorption.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>19916<\/li><li>20536<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ar1170.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Exemple d\u2019application : radiello 165<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Le contr\u00f4le des compos\u00e9s carbonyl\u00e9s ald\u00e9hydes et c\u00e9tones dans l\u2019air est n\u00e9cessaire pour assurer la protection des personnes et de l\u2019environnement. Le tube pour pr\u00e9l\u00e8vement passif radiello 165 (RAD165) est id\u00e9al pour l\u2019\u00e9chantillonnage de ces compos\u00e9s aussi bien dans l\u2019air int\u00e9rieur que dans l\u2019air ext\u00e9rieur. Sa conception radiale 3D autorise des vitesses d\u2019\u00e9chantillonnage \u00e9lev\u00e9es permettant la d\u00e9tection de concentrations au stade de la ppbv avec des dur\u00e9es de pr\u00e9l\u00e8vement courtes. Si besoin, des pr\u00e9l\u00e8vements de longue dur\u00e9e sont possibles du fait de la grande capacit\u00e9 d\u2019adsorption des tubes radiello.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\">Pr\u00e9l\u00e8vement de 16 heures avec un tube radiello 165 dans un centre d\u2019exp\u00e9dition<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ar0508.png\" alt=\"16-Hr Laboratory Air Sample with radiello 165\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_AR0508<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-4 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 50px\">t<sub>R<\/sub> (min)<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Formaldehyde-DNPH\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1081-15-8\/Formaldehyde-DNPH\" target=\"_blank\" rel=\"noopener\">Formaldehyde-DNPH<\/a><\/td><td class=\"oth\">2.80<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetaldehyde-DNPH\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1019-57-4\/Acetaldehyde-DNPH\" target=\"_blank\" rel=\"noopener\">Acetaldehyde-DNPH<\/a><\/td><td class=\"oth\">3.47<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetone-DNPH\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1567-89-1\/Acetone-DNPH\" target=\"_blank\" rel=\"noopener\">Acetone-DNPH<\/a><\/td><td class=\"oth\">4.55<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for n-Butyraldehyde-DNPH\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1527-98-6\/n-Butyraldehyde-DNPH\" target=\"_blank\" rel=\"noopener\">n-Butyraldehyde-DNPH<\/a><\/td><td class=\"oth\">6.58<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexanal-DNPH\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1527-97-5\/Hexanal-DNPH\" target=\"_blank\" rel=\"noopener\">Hexanal-DNPH<\/a><\/td><td class=\"oth\">10.10<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor C18  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9304A65\" rel=\"noopener\">cat.# 9304A65<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>150 mm x 4.6 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>30 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Laboratory air sample<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>2 mL acetonitrile extract<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol:acetonitrile (650:50)* <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.8<\/td><td>30<\/td><td>70<\/td><\/tr><tr><td>5.00<\/td><td>0.8<\/td><td>25<\/td><td>75<\/td><\/tr><tr><td>11.00<\/td><td>0.8<\/td><td>10<\/td><td>90<\/td><\/tr><tr><td>11.01<\/td><td>0.8<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>12.00<\/td><td>0.8<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>12.01<\/td><td>0.8<\/td><td>30<\/td><td>70<\/td><\/tr><tr><td>14.00<\/td><td>0.8<\/td><td>30<\/td><td>70<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>UV\/Vis @ 365, 4.8 nm<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Preconcentrator<\/th><td>radiello 165<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Waters ACQUITY UPLC H-Class<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>The radiello 165 passive air sampler (RAD165) utilizes a stainless steel net cartridge filled with 2,4-dinitrophenylhydrazine (DNPH) coated Florisil adsorbent. Airborne carbonyls react with the DNPH to form stable hydrazones. The derivatives were subsequently extracted for 30 minutes with 2 mL of acetonitrile. The extract was then analyzed by LC-UV.<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>*Mobile phase B was prepared by combining 650 mL methanol and 50 mL acetonitrile.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9304A65<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ar0508.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>D\u00e9sormais distribu\u00e9s par Restek, les tubes radiello font appel \u00e0 une technologie radiale 3D pr\u00e9sentant de nombreux avantages par rapport aux \u00e9chantillonneurs conventionnels axiaux plats 2D. Ces tubes constituent une solution alternative de pr\u00e9l\u00e8vement fiable et \u00e9conomique. Ils offrent une grande sensibilit\u00e9 permettant la d\u00e9tection de faibles concentrations m\u00eame avec des pr\u00e9l\u00e8vements courts. Leur grande capacit\u00e9 autorise des pr\u00e9l\u00e8vements de longue dur\u00e9e donc des r\u00e9sultats plus fiables. Il existe une large gamme de tubes radiello adapt\u00e9s \u00e0 diverses familles de compos\u00e9s chimiques. Il est ainsi possible de choisir le tube radiello contenant l\u2019adsorbant id\u00e9al pour une application donn\u00e9e.<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[462],"tags":[],"industries-application":[2209,2208,2211],"post-badge":[],"resource-type":[],"product-library":[2443,2453],"resource-technique":[2315],"ppma_author":[414],"class_list":["post-43828","post","type-post","status-publish","format-standard","hentry","category-articles-fr","industries-application-analyses-de-lair","industries-application-environnement","industries-application-hygiene-industrielle","product-library-echantillonnage-dair-et-de-gaz","product-library-echantillonneurs-dair-individuels-accessoires","resource-technique-echantillonnage-dair"],"acf":[],"taxonomy_info":{"category":[{"value":462,"label":"Articles"}],"industries-application":[{"value":2209,"label":"Analyses de l'air"},{"value":2208,"label":"Environnement"},{"value":2211,"label":"Hygi\u00e8ne Industrielle"}],"product-library":[{"value":2443,"label":"\u00c9chantillonnage d'air et de gaz"},{"value":2453,"label":"\u00c9chantillonneurs d&#039;air individuels et accessoires"}],"resource-technique":[{"value":2315,"label":"\u00c9chantillonnage d'air"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":462,"name":"Articles","slug":"articles-fr","term_group":0,"term_taxonomy_id":462,"taxonomy":"category","description":"","parent":0,"count":509,"filter":"raw","cat_ID":462,"category_count":509,"category_description":"","cat_name":"Articles","category_nicename":"articles-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43828","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=43828"}],"version-history":[{"count":26,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43828\/revisions"}],"predecessor-version":[{"id":85738,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/43828\/revisions\/85738"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=43828"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=43828"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=43828"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=43828"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=43828"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=43828"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=43828"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=43828"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=43828"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}