{"id":45258,"date":"2020-10-28T00:00:00","date_gmt":"2020-10-28T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/analysis-of-pesticides-and-mycotoxins-in-cannabis-brownies\/"},"modified":"2026-08-10T18:52:25","modified_gmt":"2026-08-10T18:52:25","slug":"analysis-of-pesticides-and-mycotoxins-in-cannabis-brownies","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/application-notes\/ffan3149\/analysis-of-pesticides-and-mycotoxins-in-cannabis-brownies","title":{"rendered":"Analysis of Pesticides and Mycotoxins in Cannabis Brownies"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Abstract<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Government regulations in California require the cannabis industry to test edible products for an extensive list of pesticides and mycotoxins. Here, an effective workflow for this complex analysis was developed in brownies, and optimization strategies are detailed in order to provide a starting point for similar matrices. Both LC-MS\/MS and GC-MS\/MS were employed and excellent results for LOQ, linearity, accuracy, and precision were attained for all the target compounds.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Introduction<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Legalization of cannabis (marijuana) for recreational and medical purposes demands accurate, reliable analytical methods to assess the quality and safety of any cannabis-derived product. Developing effective methods requires careful consideration of analyte properties and matrix effects, and testing is further complicated because requirements vary by country and state for different product types. Among the various commercially available cannabis products, edibles constitute one of the most popular categories. Edibles encompass a broad variety of products, including several types of beverages, chocolates, baked goods, and candy among others. Currently, the state of California demands the analysis of an extensive list of pesticides and mycotoxins not only in cannabis flower but also in cannabis-derived goods [1]. For this reason, methods capable of tackling challenges for different matrices are highly desired.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The work presented here describes the development of a test method for the analysis of pesticides and mycotoxins in cannabis brownies using the California list. We selected brownies as a model matrix due to their popularity among cannabis edibles users, and also because they contain high levels of potential interferences (carbohydrates and fats). We discuss the development work that was necessary to optimize this method for brownies as a point of reference for labs developing methods for similar edibles (e.g., cookies or other baked goods). The final method established here for the analysis of pesticides and mycotoxins in cannabis brownies provided excellent results in terms of linearity, accuracy, precision, and limits of quantitation (LOQs).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Experimental<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Initially, method development work was performed to optimize the sample preparation procedure and to assess the impact of matrix effects on quantitative analysis. The outcome of those experiments is discussed in the results section, and the final recommended methodology for the analysis of pesticides and mycotoxins in cannabis brownies is presented here.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Sample Preparation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For a solid sample like brownies, the first step in sample preparation is matrix homogenization. We used a SPEX Freezer\/Mill grinder to pulverize the sample into a fine powder. Samples were precooled for 2 min, then, three cycles of 2 min grinding (at 15 cps) and 1 min cooling produced a loose, homogeneous powder that was easy to work with. (Alternatively, a food processor with dry ice could be used.)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pulverized blank brownie matrix (0.5 g) was weighed into 4.0 mL glass vials (cat.# 24654) and fortified with pesticides and mycotoxins at the levels defined in Table I. A mixture of internal standards was added at 200 ng\/g (compounds listed in Table II). 1.5 mL of acetonitrile acidified with 1% acetic acid was added to the sample. The sample was vortexed and sonicated for 5 min (no centrifugation required), and then the supernatant was passed through a 100 mg Resprep C18 SPE cartridge (cat.# 26030). An additional 1.5 mL of extraction solvent (acidified acetonitrile) was added to the sample pellet, and then the sample was vortexed again. The supernatant was passed through the same C18 cartridge.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For LC-MS\/MS analysis, 750 \u00b5L of supernatant was mixed with 250 \u00b5L of water, and then centrifuged for 5 min at a low temperature (~7 \u2070C). A 2 \u03bcL aliquot of final extract was injected into the LC-MS\/MS system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For GC-MS\/MS analysis, the remaining supernatant was transferred to a Q-sep QuEChERS dSPE tube containing pre-weighed magnesium sulfate and PSA (cat.# 26215). After vortexing and centrifuging, 500 \u03bcL of extract was mixed with 500 \u03bcL of acidified acetonitrile. A 1 \u03bcL aliquot of final extract was injected into the GC-MS\/MS system.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Calibration Standards and Quality Control (QC) Samples<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A nine-point calibration curve ranging from 5 to 700 ng\/g was prepared in matrix in triplicate to assess linearity and allow quantitative analysis. To evaluate method accuracy and precision, three different QC concentration levels (10, 100, and 500 ng\/g) were prepared in quadruplicate. For both the calibration standards and the QC samples, 0.5 g of pulverized blank brownie samples were weighed in 4 mL vials. Table I summarizes the \u00b5L of stock solution added to each vial to obtain different concentrations in matrix.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I<\/strong>: Preparation of calibration standard and QC sample concentration levels.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th><strong>Description<\/strong><\/th><th><strong>Concentration in<br>Matrix (ng\/g)<\/strong><\/th><th><strong>Volume of Fortification<br>Solution Added (\u00b5L)<\/strong><\/th><th><strong>Concentration of<br>Fortification Solution (ng\/mL)<\/strong><\/th><\/tr><\/thead><tbody><tr><td>Calibration 1<\/td><td>5<\/td><td>10<\/td><td>250<\/td><\/tr><tr><td>QC Low<\/td><td>10<\/td><td>20<\/td><td>250<\/td><\/tr><tr><td>Calibration 2<\/td><td>25<\/td><td>50<\/td><td>250<\/td><\/tr><tr><td>Calibration 3<\/td><td>50<\/td><td>25<\/td><td>1000<\/td><\/tr><tr><td>Calibration 4<\/td><td>75<\/td><td>37.5<\/td><td>1000<\/td><\/tr><tr><td>QC Medium<\/td><td>100<\/td><td>50<\/td><td>1000<\/td><\/tr><tr><td>Calibration 5<\/td><td>150<\/td><td>15<\/td><td>5000<\/td><\/tr><tr><td>Calibration 6<\/td><td>200<\/td><td>20<\/td><td>5000<\/td><\/tr><tr><td>Calibration 7<\/td><td>300<\/td><td>30<\/td><td>5000<\/td><\/tr><tr><td>Calibration 8<\/td><td>400<\/td><td>40<\/td><td>5000<\/td><\/tr><tr><td>QC High<\/td><td>500 &nbsp;<\/td><td>50<\/td><td>5000<\/td><\/tr><tr><td>Calibration 9<\/td><td>700<\/td><td>70<\/td><td>5000<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table II<\/strong>: Internal standards (ISTD) and target compounds for LC analysis (atrazine-D5 was used for GC analysis shown in Figure 2.)<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Compound<\/strong><\/td><td><strong>Type<\/strong><\/td><td><strong>ISTD Group<\/strong><\/td><\/tr><tr><td>Daminozide-D6<\/td><td>ISTD<\/td><td>8<\/td><\/tr><tr><td>Daminozide<\/td><td>Target<\/td><td>8<\/td><\/tr><tr><td>Acephate<\/td><td>Target<\/td><td>3<\/td><\/tr><tr><td>Oxamyl<\/td><td>Target<\/td><td>2<\/td><\/tr><tr><td>Flonicamid<\/td><td>Target<\/td><td>3<\/td><\/tr><tr><td>Methomyl<\/td><td>Target<\/td><td>2<\/td><\/tr><tr><td>Thiamethoxam<\/td><td>Target<\/td><td>2<\/td><\/tr><tr><td>Imidacloprid<\/td><td>Target<\/td><td>2<\/td><\/tr><tr><td>Mevinphos I<\/td><td>Target<\/td><td>2<\/td><\/tr><tr><td>Mevinphos II<\/td><td>Target<\/td><td>2<\/td><\/tr><tr><td>Acetamiprid<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Dimethoathe-D6<\/td><td>ISTD<\/td><td>3<\/td><\/tr><tr><td>Dimethoate<\/td><td>Target<\/td><td>3<\/td><\/tr><tr><td>Thiacloprid<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Aldicarb<\/td><td>Target<\/td><td>2<\/td><\/tr><tr><td>Dichlorvos<\/td><td>Target<\/td><td>4<\/td><\/tr><tr><td>Dichlorvos-D6<\/td><td>ISTD<\/td><td>4<\/td><\/tr><tr><td>Imazalil<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Carbofuran<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Propoxur<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Carbaryl-D7<\/td><td>ISTD<\/td><td>5<\/td><\/tr><tr><td>Carbaryl<\/td><td>Target<\/td><td>5<\/td><\/tr><tr><td>Diuron-D6<\/td><td>ISTD<\/td><td>2<\/td><\/tr><tr><td>Atrazine-D5<\/td><td>ISTD<\/td><td>7<\/td><\/tr><tr><td>Naled<\/td><td>Target<\/td><td>2<\/td><\/tr><tr><td>Metalaxyl<\/td><td>Target<\/td><td>2<\/td><\/tr><tr><td>Spiroxamin<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Chlorantraniliprole<\/td><td>Target<\/td><td>2<\/td><\/tr><tr><td>Phosmet<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Azoxystrobin<\/td><td>Target<\/td><td>2<\/td><\/tr><tr><td>Linuron-D6<\/td><td>ISTD<\/td><td>1<\/td><\/tr><tr><td>Fludioxonil<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Methiocarb<\/td><td>Target<\/td><td>2<\/td><\/tr><tr><td>Boscalid<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Dimethomorph I<\/td><td>Target<\/td><td>2<\/td><\/tr><tr><td>Paclobutrazol<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Dimethomorph II<\/td><td>Target<\/td><td>2<\/td><\/tr><tr><td>Malathion<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Myclobutanil<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Bifenazate<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Fenhexamid<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Spirotetramat<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Fipronil<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Ethoprophos<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Fenoxycarb<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Kresoxim methyl<\/td><td>Target<\/td><td>6<\/td><\/tr><tr><td>Tebuconazole<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Diazinon-D10<\/td><td>ISTD<\/td><td>6<\/td><\/tr><tr><td>Diazinon<\/td><td>Target<\/td><td>6<\/td><\/tr><tr><td>Spinosad A<\/td><td>Target<\/td><td>6<\/td><\/tr><tr><td>Pyridaben<\/td><td>Target<\/td><td>6<\/td><\/tr><tr><td>Coumaphos<\/td><td>Target<\/td><td>6<\/td><\/tr><tr><td>Propiconazole<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Clofentezine<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Spinosad (Spinosyn D)<\/td><td>Target<\/td><td>6<\/td><\/tr><tr><td>Spinetoram (Spinosyn J)<\/td><td>Target<\/td><td>6<\/td><\/tr><tr><td>Prallethrin<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Trifloxystrobin<\/td><td>Target<\/td><td>6<\/td><\/tr><tr><td>Pyrethrin II<\/td><td>Target<\/td><td>6<\/td><\/tr><tr><td>Spinetoram (Spinosyn L)<\/td><td>Target<\/td><td>6<\/td><\/tr><tr><td>Piperonyl butoxide<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Chlorpyrifos<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Hexythiazox<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Etoxazole<\/td><td>Target<\/td><td>6<\/td><\/tr><tr><td>Spiromesifen<\/td><td>Target<\/td><td>6<\/td><\/tr><tr><td>Pyrethrin I<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Cyfluthrin<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>(E)-Fenpyroximate<\/td><td>Target<\/td><td>6<\/td><\/tr><tr><td>Cypermethrin<\/td><td>Target<\/td><td>2<\/td><\/tr><tr><td>Abamectine<\/td><td>Target<\/td><td>6<\/td><\/tr><tr><td>Permethrin-<em>trans<\/em><\/td><td>Target<\/td><td>6<\/td><\/tr><tr><td>Permethrin-<em>cis<\/em><\/td><td>Target<\/td><td>6<\/td><\/tr><tr><td>Etofenprox<\/td><td>Target<\/td><td>6<\/td><\/tr><tr><td>Bifenthrin<\/td><td>Target<\/td><td>2<\/td><\/tr><tr><td>Acequinocyl 343<\/td><td>Target<\/td><td>6<\/td><\/tr><tr><td>Acequinocyl 402<\/td><td>Target<\/td><td>6<\/td><\/tr><tr><td>Aflatoxin G2<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Aflatoxin G1<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Aflatoxin B2<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Ochratoxin A<\/td><td>Target<\/td><td>1<\/td><\/tr><tr><td>Aflatoxin B1<\/td><td>Target<\/td><td>1<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Instrument Conditions<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">LC-MS\/MS analysis of pesticides and mycotoxins in cannabis brownies was performed using a 2.7 \u00b5m x 100 mm x 2.1 mm Raptor ARC-18 analytical column (cat.# 9314A12) and a Shimadzu LCMS-8060 LC-MS\/MS. General instrument conditions, compound-specific ESI polarity, and analyte transitions are provided in Figure 1.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">GC-MS\/MS analysis was performed using a 30 m x 0.25 mm x 0.25 \u00b5m Rxi-5ms (cat.# 13423) analytical column and a Thermo Scientific TSQ 8000 triple quadrupole GC-MS\/MS. Instrument conditions and analyte transitions are provided in Figure 2. Note that it was important to use a single taper inlet liner with wool (cat.# 23447) for this application. The wool packing enhances vaporization and mixing\/homogenization with the carrier gas for better reproducibility, and the taper at the bottom of the liner funnels analytes onto the column, reducing the potential for interactions with the inlet seal. In addition, a 10 min hold time was used at the end of each run in order to ensure that compounds would not carry over and interfere with subsequent analyses.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Results and Discussion<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Chromatographic Performance<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">In order to cover all of the compounds regulated by the state of California, we developed both LC-MS\/MS and GC-MS\/MS methods. Although the majority of pesticides are easily analyzed using LC-MS\/MS, hydrophobic pesticides, such as chlordane, methyl parathion, captan, chlorfenapyr, and pentachloronitrobenzene (PCNB), are either not detectable or are very poorly ionized under electrospray ionization conditions. Other pesticides, such as cyfluthrin and cypermethrin, have rather low responses in ESI, but they can be analyzed using both GC-MS\/MS and LC-MS\/MS instrumental methods. In order to achieve an acceptable ESI response for these two analytes, ionization source temperatures should be set at relative low values. In our case, the interface, desolvation line, and heating block temperatures were all set at 100 \u00b0C. In this work, chlordane, methyl parathion, captan, chlorfenapyr, and pentachloronitrobenzene (PCNB) were analyzed using GC-MS\/MS; cyfluthrin and cypermethrin were analyzed using both instrumental platforms; and the rest of the pesticides and mycotoxins were run using only LC-MS\/MS. Figures 1 and 2 show the LC and GC chromatograms for the target analytes, respectively. One of the main advantages of our LC gradient conditions is that all mycotoxins elute between 2.4 and 3.6 minutes, while the main cannabinoids, such as CBD, CBG, CBN, THC, and THCA-A, will start to elute after 5.6 min. Based on a comparison to a mixed cannabinoids standard analyzed under the same conditions used here, the only coelutions between the target analytes and the main cannabinoids would be between CBD and piperonyl butoxide (5.7 min); CBG and chlorpyrifos (5.8); and cyfluthrin and CBN (6.5 min). THC (delta 8 and 9) and THCA-A did not coelute with any of the target compounds.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong>\u00a0LC-MS\/MS analysis of pesticides and mycotoxins in cannabis brownies.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_gn0602.png\" alt=\"California Cannabis Pesticides and Mycotoxins in Brownies on Raptor ARC-18\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_GN0602<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion 1<\/th><th style=\"text-align: center;width: 75px\">Product Ion 2<\/th><th style=\"text-align: center;width: 75px\">Polarity<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\">Daminozide-d6<\/td><td class=\"oth\">0.6<\/td><td class=\"oth\">167.0<\/td><td class=\"oth\">149.3<\/td><td class=\"oth\">49.3<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Daminozide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1596-84-5\/Daminozide\" target=\"_blank\" rel=\"noopener\">Daminozide<\/a><\/td><td class=\"oth\">0.7<\/td><td class=\"oth\">161.1<\/td><td class=\"oth\">44.1<\/td><td class=\"oth\">143.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acephate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/30560-19-1\/Acephate\" target=\"_blank\" rel=\"noopener\">Acephate<\/a><\/td><td class=\"oth\">1.5<\/td><td class=\"oth\">184.0<\/td><td class=\"oth\">143.1<\/td><td class=\"oth\">95.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Oxamyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/23135-22-0\/Oxamyl\" target=\"_blank\" rel=\"noopener\">Oxamyl<\/a><\/td><td class=\"oth\">1.8<\/td><td class=\"oth\">237.1<\/td><td class=\"oth\">72.1<\/td><td class=\"oth\">90.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flonicamid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/158062-67-0\/Flonicamid\" target=\"_blank\" rel=\"noopener\">Flonicamid<\/a><\/td><td class=\"oth\">1.9<\/td><td class=\"oth\">230.1<\/td><td class=\"oth\">203.1<\/td><td class=\"oth\">174.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methomyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/16752-77-5\/Methomyl\" target=\"_blank\" rel=\"noopener\">Methomyl<\/a><\/td><td class=\"oth\">1.9<\/td><td class=\"oth\">163.1<\/td><td class=\"oth\">88.1<\/td><td class=\"oth\">106.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Thiamethoxam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/153719-23-4\/Thiamethoxam\" target=\"_blank\" rel=\"noopener\">Thiamethoxam<\/a><\/td><td class=\"oth\">1.9<\/td><td class=\"oth\">292.0<\/td><td class=\"oth\">211.1<\/td><td class=\"oth\">181.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Imidacloprid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/138261-41-3\/Imidacloprid\" target=\"_blank\" rel=\"noopener\">Imidacloprid<\/a><\/td><td class=\"oth\">2.2<\/td><td class=\"oth\">256.1<\/td><td class=\"oth\">209.1<\/td><td class=\"oth\">175.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mevinphos I\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7786-34-7\/Mevinphos I\" target=\"_blank\" rel=\"noopener\">Mevinphos I<\/a><\/td><td class=\"oth\">2.2<\/td><td class=\"oth\">225.1<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">193.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetamiprid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/135410-20-7\/Acetamiprid\" target=\"_blank\" rel=\"noopener\">Acetamiprid<\/a><\/td><td class=\"oth\">2.2<\/td><td class=\"oth\">223.0<\/td><td class=\"oth\">126.1<\/td><td class=\"oth\">56.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\">Dimethoathe-d6<\/td><td class=\"oth\">2.2<\/td><td class=\"oth\">236.1<\/td><td class=\"oth\">205.1<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dimethoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60-51-5\/Dimethoate\" target=\"_blank\" rel=\"noopener\">Dimethoate<\/a><\/td><td class=\"oth\">2.3<\/td><td class=\"oth\">230.0<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">125.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Thiacloprid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111988-49-9\/Thiacloprid\" target=\"_blank\" rel=\"noopener\">Thiacloprid<\/a><\/td><td class=\"oth\">2.4<\/td><td class=\"oth\">253.0<\/td><td class=\"oth\">126.0<\/td><td class=\"oth\">90.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mevinphos II\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7786-34-7\/Mevinphos II\" target=\"_blank\" rel=\"noopener\">Mevinphos II<\/a><\/td><td class=\"oth\">2.4<\/td><td class=\"oth\">225.1<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">193.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aflatoxin G2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7241-98-7\/Aflatoxin G2\" target=\"_blank\" rel=\"noopener\">Aflatoxin G2<\/a><\/td><td class=\"oth\">2.4<\/td><td class=\"oth\">331.2<\/td><td class=\"oth\">189.3<\/td><td class=\"oth\">115.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aflatoxin G1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1165-39-5\/Aflatoxin G1\" target=\"_blank\" rel=\"noopener\">Aflatoxin G1<\/a><\/td><td class=\"oth\">2.4<\/td><td class=\"oth\">329.2<\/td><td class=\"oth\">243.2<\/td><td class=\"oth\">215.3<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aldicarb\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/116-06-3\/Aldicarb\" target=\"_blank\" rel=\"noopener\">Aldicarb<\/a><\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">116.0<\/td><td class=\"oth\">89.2<\/td><td class=\"oth\">70.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aflatoxin B2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7220-81-7\/Aflatoxin B2\" target=\"_blank\" rel=\"noopener\">Aflatoxin B2<\/a><\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">315.3<\/td><td class=\"oth\">287.2<\/td><td class=\"oth\">243.3<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dichlorvos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62-73-7\/Dichlorvos\" target=\"_blank\" rel=\"noopener\">Dichlorvos<\/a><\/td><td class=\"oth\">2.6<\/td><td class=\"oth\">220.9<\/td><td class=\"oth\">109.1<\/td><td class=\"oth\">79.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\">Dichlorvos-d6<\/td><td class=\"oth\">2.6<\/td><td class=\"oth\">227.0<\/td><td class=\"oth\">115.1<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aflatoxin B1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1162-65-8\/Aflatoxin B1\" target=\"_blank\" rel=\"noopener\">Aflatoxin B1<\/a><\/td><td class=\"oth\">2.6<\/td><td class=\"oth\">313.2<\/td><td class=\"oth\">241.2<\/td><td class=\"oth\">128.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Imazalil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/35554-44-0\/Imazalil\" target=\"_blank\" rel=\"noopener\">Imazalil<\/a><\/td><td class=\"oth\">2.6<\/td><td class=\"oth\">297.0<\/td><td class=\"oth\">159.0<\/td><td class=\"oth\">201.0<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carbofuran\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1563-66-2\/Carbofuran\" target=\"_blank\" rel=\"noopener\">Carbofuran<\/a><\/td><td class=\"oth\">2.6<\/td><td class=\"oth\">222.1<\/td><td class=\"oth\">123.1<\/td><td class=\"oth\">165.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propoxur\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/114-26-1\/Propoxur\" target=\"_blank\" rel=\"noopener\">Propoxur<\/a><\/td><td class=\"oth\">2.6<\/td><td class=\"oth\">210.1<\/td><td class=\"oth\">111.1<\/td><td class=\"oth\">93.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carbaryl-d7\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/362049-56-7\/Carbaryl-d7\" target=\"_blank\" rel=\"noopener\">Carbaryl-d7<\/a><\/td><td class=\"oth\">2.7<\/td><td class=\"oth\">209.2<\/td><td class=\"oth\">152.2<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carbaryl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/63-25-2\/Carbaryl\" target=\"_blank\" rel=\"noopener\">Carbaryl<\/a><\/td><td class=\"oth\">2.7<\/td><td class=\"oth\">202.1<\/td><td class=\"oth\">145.1<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\">Diuron-d6<\/td><td class=\"oth\">2.9<\/td><td class=\"oth\">239.1<\/td><td class=\"oth\">78.2<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Atrazine-d5\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/163165-75-1\/Atrazine-d5\" target=\"_blank\" rel=\"noopener\">Atrazine-d5<\/a><\/td><td class=\"oth\">2.9<\/td><td class=\"oth\">221.2<\/td><td class=\"oth\">179.1<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">29.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Naled\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/300-76-5\/Naled\" target=\"_blank\" rel=\"noopener\">Naled<\/a><\/td><td class=\"oth\">2.9<\/td><td class=\"oth\">397.8<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">109.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">30.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Metalaxyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57837-19-1\/Metalaxyl\" target=\"_blank\" rel=\"noopener\">Metalaxyl<\/a><\/td><td class=\"oth\">2.9<\/td><td class=\"oth\">280.2<\/td><td class=\"oth\">220.2<\/td><td class=\"oth\">192.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">31.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Spiroxamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/118134-30-8\/Spiroxamine\" target=\"_blank\" rel=\"noopener\">Spiroxamine<\/a><\/td><td class=\"oth\">2.9<\/td><td class=\"oth\">298.3<\/td><td class=\"oth\">144.2<\/td><td class=\"oth\">100.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">32.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorantraniliprole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/500008-45-7\/Chlorantraniliprole\" target=\"_blank\" rel=\"noopener\">Chlorantraniliprole<\/a><\/td><td class=\"oth\">3.0<\/td><td class=\"oth\">483.9<\/td><td class=\"oth\">452.9<\/td><td class=\"oth\">285.9<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">33.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phosmet\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/732-11-6\/Phosmet\" target=\"_blank\" rel=\"noopener\">Phosmet<\/a><\/td><td class=\"oth\">3.0<\/td><td class=\"oth\">318.0<\/td><td class=\"oth\">160.1<\/td><td class=\"oth\">77.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">34.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Azoxystrobin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/131860-33-8\/Azoxystrobin\" target=\"_blank\" rel=\"noopener\">Azoxystrobin<\/a><\/td><td class=\"oth\">3.1<\/td><td class=\"oth\">404.0<\/td><td class=\"oth\">372.1<\/td><td class=\"oth\">344.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">35.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Linuron-d6\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1219804-76-8\/Linuron-d6\" target=\"_blank\" rel=\"noopener\">Linuron-d6<\/a><\/td><td class=\"oth\">3.1<\/td><td class=\"oth\">255.1<\/td><td class=\"oth\">160.1<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">36.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fludioxonil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/131341-86-1\/Fludioxonil\" target=\"_blank\" rel=\"noopener\">Fludioxonil<\/a><\/td><td class=\"oth\">3.2<\/td><td class=\"oth\">247.0<\/td><td class=\"oth\">180.0<\/td><td class=\"oth\">126.0<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">37.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methiocarb\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2032-65-7\/Methiocarb\" target=\"_blank\" rel=\"noopener\">Methiocarb<\/a><\/td><td class=\"oth\">3.2<\/td><td class=\"oth\">226.1<\/td><td class=\"oth\">169.1<\/td><td class=\"oth\">121.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">38.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dimethomorph I\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110488-70-5\/Dimethomorph I\" target=\"_blank\" rel=\"noopener\">Dimethomorph I<\/a><\/td><td class=\"oth\">3.2<\/td><td class=\"oth\">388.2<\/td><td class=\"oth\">301.2<\/td><td class=\"oth\">165.3<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">39.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Boscalid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/188425-85-6\/Boscalid\" target=\"_blank\" rel=\"noopener\">Boscalid<\/a><\/td><td class=\"oth\">3.2<\/td><td class=\"oth\">342.9<\/td><td class=\"oth\">307.1<\/td><td class=\"oth\">140.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">40.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Paclobutrazol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76738-62-0\/Paclobutrazol\" target=\"_blank\" rel=\"noopener\">Paclobutrazol<\/a><\/td><td class=\"oth\">3.3<\/td><td class=\"oth\">294.3<\/td><td class=\"oth\">70.1<\/td><td class=\"oth\">125.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">41.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Malathion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/121-75-5\/Malathion\" target=\"_blank\" rel=\"noopener\">Malathion<\/a><\/td><td class=\"oth\">3.3<\/td><td class=\"oth\">331.0<\/td><td class=\"oth\">127.2<\/td><td class=\"oth\">285.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">42.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dimethomorph II\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110488-70-5\/Dimethomorph II\" target=\"_blank\" rel=\"noopener\">Dimethomorph II<\/a><\/td><td class=\"oth\">3.4<\/td><td class=\"oth\">388.2<\/td><td class=\"oth\">301.2<\/td><td class=\"oth\">165.3<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">43.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Myclobutanil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88671-89-0\/Myclobutanil\" target=\"_blank\" rel=\"noopener\">Myclobutanil<\/a><\/td><td class=\"oth\">3.4<\/td><td class=\"oth\">289.1<\/td><td class=\"oth\">70.1<\/td><td class=\"oth\">125.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">44.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bifenazate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/149877-41-8\/Bifenazate\" target=\"_blank\" rel=\"noopener\">Bifenazate<\/a><\/td><td class=\"oth\">3.4<\/td><td class=\"oth\">301.0<\/td><td class=\"oth\">198.1<\/td><td class=\"oth\">170.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">45.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ochratoxin A\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/303-47-9\/Ochratoxin A\" target=\"_blank\" rel=\"noopener\">Ochratoxin A<\/a><\/td><td class=\"oth\">3.5<\/td><td class=\"oth\">404.2<\/td><td class=\"oth\">239.1<\/td><td class=\"oth\">358.3<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">46.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenhexamid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/126833-17-8\/Fenhexamid\" target=\"_blank\" rel=\"noopener\">Fenhexamid<\/a><\/td><td class=\"oth\">3.5<\/td><td class=\"oth\">302.1<\/td><td class=\"oth\">97.1<\/td><td class=\"oth\">55.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">47.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Spirotetramat\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/203313-25-1\/Spirotetramat\" target=\"_blank\" rel=\"noopener\">Spirotetramat<\/a><\/td><td class=\"oth\">3.7<\/td><td class=\"oth\">374.2<\/td><td class=\"oth\">302.1<\/td><td class=\"oth\">216.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">48.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethoprophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13194-48-4\/Ethoprophos\" target=\"_blank\" rel=\"noopener\">Ethoprophos<\/a><\/td><td class=\"oth\">3.8<\/td><td class=\"oth\">243.1<\/td><td class=\"oth\">131.1<\/td><td class=\"oth\">97.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">49.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fipronil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120068-37-3\/Fipronil\" target=\"_blank\" rel=\"noopener\">Fipronil<\/a><\/td><td class=\"oth\">3.8<\/td><td class=\"oth\">436.8<\/td><td class=\"oth\">331.8<\/td><td class=\"oth\">251.9<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">50.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenoxycarb\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72490-01-8\/Fenoxycarb\" target=\"_blank\" rel=\"noopener\">Fenoxycarb<\/a><\/td><td class=\"oth\">3.9<\/td><td class=\"oth\">302.1<\/td><td class=\"oth\">88.1<\/td><td class=\"oth\">116.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">51.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Kresoxim-methyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/143390-89-0\/Kresoxim-methyl\" target=\"_blank\" rel=\"noopener\">Kresoxim-methyl<\/a><\/td><td class=\"oth\">4.1<\/td><td class=\"oth\">314.2<\/td><td class=\"oth\">267.2<\/td><td class=\"oth\">222.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">52.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tebuconazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/107534-96-3\/Tebuconazole\" target=\"_blank\" rel=\"noopener\">Tebuconazole<\/a><\/td><td class=\"oth\">4.2<\/td><td class=\"oth\">308.1<\/td><td class=\"oth\">70.1<\/td><td class=\"oth\">125.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">53.<\/td><td class=\"cmpd\">Diazinon-d10 <\/td><td class=\"oth\">4.2<\/td><td class=\"oth\">315.2<\/td><td class=\"oth\">170.2<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">54.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Spinosyn A (spinosad)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/168316-95-8\/Spinosyn A\" target=\"_blank\" rel=\"noopener\">Spinosyn A (spinosad)<\/a><\/td><td class=\"oth\">4.3<\/td><td class=\"oth\">732.4<\/td><td class=\"oth\">142.2<\/td><td class=\"oth\">98.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">55.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diazinon\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/333-41-5\/Diazinon\" target=\"_blank\" rel=\"noopener\">Diazinon<\/a><\/td><td class=\"oth\">4.3<\/td><td class=\"oth\">305.1<\/td><td class=\"oth\">169.2<\/td><td class=\"oth\">153.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">56.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Coumaphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-72-4\/Coumaphos\" target=\"_blank\" rel=\"noopener\">Coumaphos<\/a><\/td><td class=\"oth\">4.4<\/td><td class=\"oth\">363.1<\/td><td class=\"oth\">227.1<\/td><td class=\"oth\">307.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">57.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyridaben\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/96489-71-3\/Pyridaben\" target=\"_blank\" rel=\"noopener\">Pyridaben<\/a><\/td><td class=\"oth\">4.4<\/td><td class=\"oth\">365.1<\/td><td class=\"oth\">309.2<\/td><td class=\"oth\">147.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">58.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propiconazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60207-90-1\/Propiconazole\" target=\"_blank\" rel=\"noopener\">Propiconazole<\/a><\/td><td class=\"oth\">4.4<\/td><td class=\"oth\">342.0<\/td><td class=\"oth\">159.0<\/td><td class=\"oth\">69.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">59.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Clofentezine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/74115-24-5\/Clofentezine\" target=\"_blank\" rel=\"noopener\">Clofentezine<\/a><\/td><td class=\"oth\">4.5<\/td><td class=\"oth\">303.0<\/td><td class=\"oth\">138.1<\/td><td class=\"oth\">102.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">60.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Spinosyn D (spinosad)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/168316-95-8\/Spinosyn D\" target=\"_blank\" rel=\"noopener\">Spinosyn D (spinosad)<\/a><\/td><td class=\"oth\">4.8<\/td><td class=\"oth\">746.5<\/td><td class=\"oth\">142.3<\/td><td class=\"oth\">98.4<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">61.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Spinosyn J (spinetoram)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/935545-74-7\/Spinosyn J\" target=\"_blank\" rel=\"noopener\">Spinosyn J (spinetoram)<\/a><\/td><td class=\"oth\">4.8<\/td><td class=\"oth\">748.5<\/td><td class=\"oth\">142.3<\/td><td class=\"oth\">98.3<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">62.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Trifloxystrobin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/141517-21-7\/Trifloxystrobin\" target=\"_blank\" rel=\"noopener\">Trifloxystrobin<\/a><\/td><td class=\"oth\">4.9<\/td><td class=\"oth\">409.2<\/td><td class=\"oth\">186.1<\/td><td class=\"oth\">145.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">63.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Prallethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/23031-36-9\/Prallethrin\" target=\"_blank\" rel=\"noopener\">Prallethrin<\/a><\/td><td class=\"oth\">4.9<\/td><td class=\"oth\">301.2<\/td><td class=\"oth\">123.2<\/td><td class=\"oth\">105.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">64.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyrethrin II\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/121-29-9\/Pyrethrin II\" target=\"_blank\" rel=\"noopener\">Pyrethrin II<\/a><\/td><td class=\"oth\">5.2<\/td><td class=\"oth\">373.1<\/td><td class=\"oth\">161.1<\/td><td class=\"oth\">133.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">65.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Spinosyn L (spinetoram)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/935545-74-7\/Spinosyn L\" target=\"_blank\" rel=\"noopener\">Spinosyn L (spinetoram)<\/a><\/td><td class=\"oth\">5.4<\/td><td class=\"oth\">760.5<\/td><td class=\"oth\">142.2<\/td><td class=\"oth\">98.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">66.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Piperonyl butoxide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51-03-6\/Piperonyl butoxide\" target=\"_blank\" rel=\"noopener\">Piperonyl butoxide<\/a><\/td><td class=\"oth\">5.7<\/td><td class=\"oth\">356.3<\/td><td class=\"oth\">177.2<\/td><td class=\"oth\">119.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">67.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorpyrifos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2921-88-2\/Chlorpyrifos\" target=\"_blank\" rel=\"noopener\">Chlorpyrifos<\/a><\/td><td class=\"oth\">5.8<\/td><td class=\"oth\">349.9<\/td><td class=\"oth\">198.0<\/td><td class=\"oth\">97.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">68.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexythiazox\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78587-05-0\/Hexythiazox\" target=\"_blank\" rel=\"noopener\">Hexythiazox<\/a><\/td><td class=\"oth\">5.9<\/td><td class=\"oth\">353.1<\/td><td class=\"oth\">228.1<\/td><td class=\"oth\">168.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">69.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Etoxazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/153233-91-1\/Etoxazole\" target=\"_blank\" rel=\"noopener\">Etoxazole<\/a><\/td><td class=\"oth\">6.4<\/td><td class=\"oth\">360.2<\/td><td class=\"oth\">141.1<\/td><td class=\"oth\">304.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">70.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Spiromesifen\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/283594-90-1\/Spiromesifen\" target=\"_blank\" rel=\"noopener\">Spiromesifen<\/a><\/td><td class=\"oth\">6.4<\/td><td class=\"oth\">273.2<\/td><td class=\"oth\">255.2<\/td><td class=\"oth\">187.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">71.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyrethrin I\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/121-21-1\/Pyrethrin I\" target=\"_blank\" rel=\"noopener\">Pyrethrin I<\/a><\/td><td class=\"oth\">6.6<\/td><td class=\"oth\">329.2<\/td><td class=\"oth\">161.2<\/td><td class=\"oth\">105.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">72.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cyfluthrin (qualifier)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/68359-37-5\/Cyfluthrin\" target=\"_blank\" rel=\"noopener\">Cyfluthrin (qualifier)<\/a><\/td><td class=\"oth\">6.6<\/td><td class=\"oth\">453.1<\/td><td class=\"oth\">193.2<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">73.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cyfluthrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/68359-37-5\/Cyfluthrin\" target=\"_blank\" rel=\"noopener\">Cyfluthrin<\/a><\/td><td class=\"oth\">6.6<\/td><td class=\"oth\">451.1<\/td><td class=\"oth\">191.2<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">74.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cypermethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52315-07-8\/Cypermethrin\" target=\"_blank\" rel=\"noopener\">Cypermethrin<\/a><\/td><td class=\"oth\">6.8<\/td><td class=\"oth\">433.1<\/td><td class=\"oth\">191.0<\/td><td class=\"oth\">416.0<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">75.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for (E)-Fenpyroximate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111812-58-9\/(E)-Fenpyroximate\" target=\"_blank\" rel=\"noopener\">(E)-Fenpyroximate<\/a><\/td><td class=\"oth\">6.8<\/td><td class=\"oth\">422.2<\/td><td class=\"oth\">366.1<\/td><td class=\"oth\">138.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">76.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for trans-Permethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52645-53-1\/trans-Permethrin\" target=\"_blank\" rel=\"noopener\">trans-Permethrin<\/a><\/td><td class=\"oth\">7.4<\/td><td class=\"oth\">408.3<\/td><td class=\"oth\">183.2<\/td><td class=\"oth\">355.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">77.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for cis-Permethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52645-53-1\/cis-Permethrin\" target=\"_blank\" rel=\"noopener\">cis-Permethrin<\/a><\/td><td class=\"oth\">7.7<\/td><td class=\"oth\">408.3<\/td><td class=\"oth\">183.2<\/td><td class=\"oth\">355.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">78.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Avermectin B1a\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/71751-41-2\/Avermectin B1a\" target=\"_blank\" rel=\"noopener\">Avermectin B1a<\/a><\/td><td class=\"oth\">7.7<\/td><td class=\"oth\">890.5<\/td><td class=\"oth\">305.4<\/td><td class=\"oth\">567.4<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">79.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Etofenprox\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/80844-07-1\/Etofenprox\" target=\"_blank\" rel=\"noopener\">Etofenprox<\/a><\/td><td class=\"oth\">7.8<\/td><td class=\"oth\">394.3<\/td><td class=\"oth\">177.2<\/td><td class=\"oth\">359.3<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">80.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bifenthrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/82657-04-3\/Bifenthrin\" target=\"_blank\" rel=\"noopener\">Bifenthrin<\/a><\/td><td class=\"oth\">8.0<\/td><td class=\"oth\">440.0<\/td><td class=\"oth\">181.2<\/td><td class=\"oth\">166.2<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">81.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acequinocyl (precursor ion 1)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57960-19-7\/Acequinocyl\" target=\"_blank\" rel=\"noopener\">Acequinocyl (precursor ion 1)<\/a><\/td><td class=\"oth\">9.3<\/td><td class=\"oth\">402.3<\/td><td class=\"oth\">343.2<\/td><td class=\"oth\">189.0<\/td><td class=\"oth\">+<\/td><\/tr>\n<tr><td class=\"num\">82.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acequinocyl (precursor ion 2)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57960-19-7\/Acequinocyl\" target=\"_blank\" rel=\"noopener\">Acequinocyl (precursor ion 2)<\/a><\/td><td class=\"oth\">9.3<\/td><td class=\"oth\">386.0<\/td><td class=\"oth\">344.2<\/td><td class=\"oth\">189.1<\/td><td class=\"oth\">+<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor ARC-18  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9314A12\" rel=\"noopener\">cat.# 9314A12<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>Raptor ARC-18 EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9314A0252\" rel=\"noopener\">cat.# 9314A0252<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>California pesticide standard #1 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34124\" rel=\"noopener\">cat.# 34124<\/a>)<\/td><\/tr><tr><td><\/td><td>California pesticide standard #2 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34125\" rel=\"noopener\">cat.# 34125<\/a>)<\/td><\/tr><tr><td><\/td><td>California pesticide standard #3 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34126\" rel=\"noopener\">cat.# 34126<\/a>)<\/td><\/tr><tr><td><\/td><td>California pesticide standard #4 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34127\" rel=\"noopener\">cat.# 34127<\/a>)<\/td><\/tr><tr><td><\/td><td>California pesticide standard #5 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34128\" rel=\"noopener\">cat.# 34128<\/a>)<\/td><\/tr><tr><td><\/td><td>California pesticide standard #6 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34129\" rel=\"noopener\">cat.# 34129<\/a>)<\/td><\/tr><tr><td><\/td><td>Dimethoate-d6 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31988\" rel=\"noopener\">cat.# 31988<\/a>)<\/td><\/tr><tr><td><\/td><td>Dichlorvos-d6 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31987\" rel=\"noopener\">cat.# 31987<\/a>)<\/td><\/tr><tr><td><\/td><td>Carbaryl-d7 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31985\" rel=\"noopener\">cat.# 31985<\/a>)<\/td><\/tr><tr><td><\/td><td>Diazinon-d10 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31986\" rel=\"noopener\">cat.# 31986<\/a>)<\/td><\/tr><tr><td><\/td><td>Atrazine-d5 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31984\" rel=\"noopener\">cat.# 31984<\/a>)<\/td><\/tr><tr><td><\/td><td>Diuron-d6 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31989\" rel=\"noopener\">cat.# 31989<\/a>)<\/td><\/tr><tr><td><\/td><td>Liuron-d6 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31990\" rel=\"noopener\">cat.# 31990<\/a>)<\/td><\/tr><tr><td><\/td><td>Aflatoxins standard (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34121\" rel=\"noopener\">cat.# 34121<\/a>)<\/td><\/tr><tr><td><\/td><td>Ochratoxin A (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34122\" rel=\"noopener\">cat.# 34122<\/a>)<\/td><\/tr><tr><td><\/td><td>Compounds not present in these mixes were obtained separately.<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>75:25 Acetonitrile:water<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>5-15 ng\/mL (Expected concentration range in extract of brownie initially spiked at 100 ng\/g.)<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>2 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 2 mM ammonium formate, 0.1% formic acid  <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol, 2 mM ammonium formate, 0.1% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.5<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>1.5<\/td><td>0.5<\/td><td>35<\/td><td>65<\/td><\/tr><tr><td>8.5<\/td><td>0.5<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>9.5<\/td><td>0.5<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>10.5<\/td><td>0.5<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>10.6<\/td><td>0.5<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>12<\/td><td>0.5<\/td><td>95<\/td><td>5<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+\/ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>UHPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Brownies were pulverized using a SPEX Freezer\/Mill grinder and 0.5 g samples were fortified with pesticides and mycotoxins at 100 ng\/g. A mix of internal standards was added at 200 ng\/g. 1.5 mL of acetonitrile acidified with 1% acetic acid was added to the sample. The sample was vortexed and sonicated for 5 min, and then the supernatant was passed through a 100 mg Resprep C18 SPE cartridge (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/26030\" rel=\"noopener\">cat.# 26030<\/a>). An additional 1.5 mL of extraction solvent (acidified acetonitrile) was added to the sample pellet, and then the sample was vortexed again. The supernatant was passed through the same C18 cartridge. 750 \u00b5L of extract was mixed with 250 \u00b5L of water, and then centrifuged for 5 min at low temperature (~7 \u2070C). 2 \u03bcL of final extract was injected into the LC-MS\/MS system.<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Want even better performance when analyzing metal-sensitive compounds? Check out Inert LC columns at <a href=\"https:\/\/www.restek.com\/inert\" target=\"_blank\" rel=\"noopener\">www.restek.com\/inert<\/a>.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34124<\/li><li>34125<\/li><li>34126<\/li><li>34127<\/li><li>34128<\/li><li>34129<\/li><li>31988<\/li><li>31987<\/li><li>31985<\/li><li>31986<\/li><li>31984<\/li><li>31989<\/li><li>31990<\/li><li>34121<\/li><li>34122<\/li><li>9314A0252<\/li><li>9314A12<\/li><li>26030<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>California<\/li><li>Cannabis<\/li><li>Mycotoxins<\/li><li>Pesticides<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_gn0602.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong>\u00a0GC-MS\/MS analysis of pesticides and mycotoxins in cannabis brownies.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1206.png\" alt=\"GC Amenable Pesticides Regulated by California in Brownies on Rxi-5ms\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1206<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Polarity<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><th style=\"text-align: center;width: 75px\">Transition Type<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Atrazine-D5\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/163165-75-1\/Atrazine-D5\" target=\"_blank\" rel=\"noopener\">Atrazine-D5<\/a><\/td><td class=\"oth\">7.5<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">220.0<\/td><td class=\"oth\">58.0<\/td><td class=\"oth\">Quantifier<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Atrazine-D5\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/163165-75-1\/Atrazine-D5\" target=\"_blank\" rel=\"noopener\">Atrazine-D5<\/a><\/td><td class=\"oth\">7.5<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">205.0<\/td><td class=\"oth\">127.0<\/td><td class=\"oth\">Qualifier<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Quintozene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/82-68-8\/Quintozene\" target=\"_blank\" rel=\"noopener\">Quintozene<\/a><\/td><td class=\"oth\">7.8<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">294.9<\/td><td class=\"oth\">236.9<\/td><td class=\"oth\">Quantifier<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Quintozene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/82-68-8\/Quintozene\" target=\"_blank\" rel=\"noopener\">Quintozene<\/a><\/td><td class=\"oth\">7.8<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">236.8<\/td><td class=\"oth\">118.9<\/td><td class=\"oth\">Qualifier<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl parathion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-00-0\/Methyl parathion\" target=\"_blank\" rel=\"noopener\">Methyl parathion<\/a><\/td><td class=\"oth\">8.2<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">263.0<\/td><td class=\"oth\">109.0<\/td><td class=\"oth\">Quantifier<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl parathion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-00-0\/Methyl parathion\" target=\"_blank\" rel=\"noopener\">Methyl parathion<\/a><\/td><td class=\"oth\">8.2<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">263.0<\/td><td class=\"oth\">79.0<\/td><td class=\"oth\">Qualifier<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Captan\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/133-06-2\/Captan\" target=\"_blank\" rel=\"noopener\">Captan<\/a><\/td><td class=\"oth\">9.1<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">184.0<\/td><td class=\"oth\">149.1<\/td><td class=\"oth\">Quantifier<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Captan\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/133-06-2\/Captan\" target=\"_blank\" rel=\"noopener\">Captan<\/a><\/td><td class=\"oth\">9.1<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">184.0<\/td><td class=\"oth\">134.1<\/td><td class=\"oth\">Qualifier<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for trans-Chlordane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5103-74-2\/trans-Chlordane\" target=\"_blank\" rel=\"noopener\">trans-Chlordane<\/a><\/td><td class=\"oth\">9.1<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">271.9<\/td><td class=\"oth\">237.0<\/td><td class=\"oth\">Quantifier<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for trans-Chlordane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5103-74-2\/trans-Chlordane\" target=\"_blank\" rel=\"noopener\">trans-Chlordane<\/a><\/td><td class=\"oth\">9.1<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">372.9<\/td><td class=\"oth\">265.9<\/td><td class=\"oth\">Qualifier<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for cis-Chlordane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5103-71-9\/cis-Chlordane\" target=\"_blank\" rel=\"noopener\">cis-Chlordane<\/a><\/td><td class=\"oth\">9.3<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">372.9<\/td><td class=\"oth\">265.9<\/td><td class=\"oth\">Quantifier<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for cis-Chlordane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5103-71-9\/cis-Chlordane\" target=\"_blank\" rel=\"noopener\">cis-Chlordane<\/a><\/td><td class=\"oth\">9.3<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">271.9<\/td><td class=\"oth\">237.0<\/td><td class=\"oth\">Qualifier<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorfenapyr\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/122453-73-0\/Chlorfenapyr\" target=\"_blank\" rel=\"noopener\">Chlorfenapyr<\/a><\/td><td class=\"oth\">9.5<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">247.1<\/td><td class=\"oth\">227.1<\/td><td class=\"oth\">Quantifier<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorfenapyr\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/122453-73-0\/Chlorfenapyr\" target=\"_blank\" rel=\"noopener\">Chlorfenapyr<\/a><\/td><td class=\"oth\">9.5<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">59.1<\/td><td class=\"oth\">31.1<\/td><td class=\"oth\">Qualifier<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cyfluthrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/68359-37-5\/Cyfluthrin\" target=\"_blank\" rel=\"noopener\">Cyfluthrin<\/a><\/td><td class=\"oth\">11.5<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">163.0<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">Quantifier<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cyfluthrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/68359-37-5\/Cyfluthrin\" target=\"_blank\" rel=\"noopener\">Cyfluthrin<\/a><\/td><td class=\"oth\">11.5<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">170.1<\/td><td class=\"oth\">Qualifier<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cypermethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52315-07-8\/Cypermethrin\" target=\"_blank\" rel=\"noopener\">Cypermethrin<\/a><\/td><td class=\"oth\">11.7<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">163.0<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">Quantifier<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cypermethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52315-07-8\/Cypermethrin\" target=\"_blank\" rel=\"noopener\">Cypermethrin<\/a><\/td><td class=\"oth\">11.7<\/td><td class=\"oth\">Positive<\/td><td class=\"oth\">181.1<\/td><td class=\"oth\">152.1<\/td><td class=\"oth\">Qualifier<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rxi-5ms, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/13423\" rel=\"noopener\">cat.# 13423<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>California pesticide standard #1 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34124\" rel=\"noopener\">cat.# 34124<\/a>)<\/td><\/tr><tr><td><\/td><td>California pesticide standard #2 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34125\" rel=\"noopener\">cat.# 34125<\/a>)<\/td><\/tr><tr><td><\/td><td>California pesticide standard #3 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34126\" rel=\"noopener\">cat.# 34126<\/a>)<\/td><\/tr><tr><td><\/td><td>California pesticide standard #4 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34127\" rel=\"noopener\">cat.# 34127<\/a>)<\/td><\/tr><tr><td><\/td><td>California pesticide standard #5 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34128\" rel=\"noopener\">cat.# 34128<\/a>)<\/td><\/tr><tr><td><\/td><td>California pesticide standard #6 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34129\" rel=\"noopener\">cat.# 34129<\/a>)<\/td><\/tr><tr><td><\/td><td>Atrazine-d5 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31984\" rel=\"noopener\">cat.# 31984<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Acetonitrile <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>5-7.5 ng\/mL Expected concentration range in extract after extracting from brownie fortified at 100 ng\/g (final extract was diluted in half with acetonitrile).<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L splitless<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 4.0 mm ID single taper inlet liner w\/wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23447\" rel=\"noopener\">cat.# 23447<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Purge Flow:<\/th><td>5 mL\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>90 &#176;C (hold 1 min) to 310 &#176;C at 25 &#176;C\/min (hold 10 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.4 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>290 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>330 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Electron Energy:<\/th><td>70 eV<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>PFTBA <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Thermo Scientific TSQ 8000 Triple Quadrupole GC-MS<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Brownies were pulverized using a SPEX Freezer\/Mill grinder and 0.5 g samples were  fortified with pesticides and mycotoxins at 100 ng\/g. A mix of internal standards was added at 200 ng\/g. 1.5 mL of acetonitrile acidified with 1% acetic acid was added to the sample. The sample was vortexed and sonicated for 5 min, then the supernatant was passed through a 100 mg Resprep SPE C18 cartridge (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/26030\" rel=\"noopener\">cat.# 26030<\/a>). An additional 1.5 mL of extraction solvent (acidified acetonitrile) was added to the sample pellet, and the sample was vortexed again. The supernatant was passed through the same C18 cartridge. After reserving 750 \u03bcL for LC-MS analysis, the remaining supernatant was transferred to a Q-sep QuEChERS dSPE tube containing pre-weighed magnesium sulfate and PSA (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/26215\" rel=\"noopener\">cat.# 26215<\/a>). After vortexing and centrifuging, 500 \u03bcL of extract was mixed with 500 \u03bcL of acidified acetonitrile. 1 \u03bcL of final extract was injected into the GC-MS\/MS system.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34124<\/li><li>34125<\/li><li>34126<\/li><li>34127<\/li><li>34128<\/li><li>34129<\/li><li>31984<\/li><li>13423<\/li><li>23447<\/li><li>26030<\/li><li>26215<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>California<\/li><li>Cannabis<\/li><li>Pesticides<\/li><li>pesticides-food-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1206.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Method Development Considerations: Sample Preparation Optimization<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Because our list of target compounds comprises a broad range of analytes with diverse physical\/chemical properties and polarities, it is essential that the sample preparation methodology be nonselective and to also ensure that major interferences are effectively removed without losing any of the target analytes. Acetonitrile, which is the extraction solvent traditionally used in QuEChERS methods, was employed here because it allows for the recovery of a broad range of polar and nonpolar compounds. Initially, we conducted experimental trials using 1 g of sample and at least 5 mL of acetonitrile per extraction. However, by reducing the sample size to 0.5 g, we were able to cut the extraction solvent volume to 3 mL per sample and still comply with the California regulations. Decreasing solvent waste allows for greener analytical practices and reduces the costs associated with sample analysis and waste disposal. Based on these benefits, acetonitrile extraction solvent and 0.5 g samples were used for further optimization experiments.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Of all the target analytes, daminozide is one of the most challenging, and additional adjustment of the extraction procedure was required to accommodate this pesticide. Daminozide is highly polar (log P = -1.5), so it is difficult to extract completely from the brownie matrix, and it is not easily retained under reversed-phase conditions. Additionally, low molecular weight compounds, such as daminozide, are more prone to interferences and high background noise when using MS, especially when having poor chromatographic retention. Several strategies were tested to enhance the recovery of daminozide at conditions that were also favorable for the rest of the target analytes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The first parameter that was evaluated was the acidification of the extraction solvent. To this end, we compared the effect of using acetonitrile with acetic acid (AA) at 1% (v\/v) against extracting with pure acetonitrile. Figure 3 shows the results for those target compounds that exhibited at least a 40% difference between treatments. When extracting with acidified acetonitrile, the relative response of daminozide increased by about 80%, whereas spiroxamine and ochratoxin A showed an improvement of 45 and 47% in response, respectively. Based on these findings, and the fact that none of the target compounds showed a significant decrease in response, we used acetonitrile with 1% acetic acid as the extraction solvent in our final sample preparation workflow. This provides an additional benefit in that acidification of the extracts avoids the degradation of captan, a pesticide suitable for GC-MS\/MS analysis that easily degrades at neutral to high pH values [2].<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The second sample preparation parameter we evaluated was the application of a single 3 mL extraction versus a two-step (1.5 mL each) extraction. Figure 4 summarizes the results for those analytes that exhibited statistical differences (t-test, p-value &lt;0.05 at a 95% confidence) between the two extraction conditions (both of which used acidified acetonitrile). Interestingly, daminozide exhibited the most significant improvement, with 40% increase in its relative response. The other analytes in the figure showed improvements in response ranging from 10 to 20%. The increase in relative responses seen here when using a second extraction step should result in higher sample extraction recoveries in real-world samples. As this effect depends on the analyte, matrix, and extraction solvent, an evaluation at the desired experimental conditions is always recommended.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Following extraction with acidified acetonitrile, a simple cleanup step with C18 SPE cartridges was used for all samples to remove major hydrophobic interferences that were coextracted from brownies. After this, samples for LC-MS\/MS and GC-MS\/MS analysis were processed differently. LC-MS\/MS samples were diluted in water and centrifuged, which permitted the separation of any remaining lipids that were not retained in the SPE cartridge because they are less soluble in the final extract once water is added. GC-MS\/MS samples were treated with magnesium sulfate and primary secondary amine (PSA) dSPE cleanup to remove moisture and sugars prior to analysis. Note that because PSA can bind to pesticides such as daminozide and spiroxamine, dSPE was conducted only for the GC amenable pesticides.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong>\u00a0Effect of acidification of the extraction solvent (n=3). Error bars correspond to standard deviations.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image45258_53c23d-5b .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image45258_53c23d-5b\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"591\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-03-1024x591.jpg\" alt=\"\" class=\"kb-img wp-image-19804\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-03-1024x591.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-03-300x173.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-03-768x443.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-03-1536x886.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-03.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4:<\/strong>\u00a0Comparison of relative responses corresponding to a two-step extraction vs. a single-step extraction (n=3).<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image45258_062fb1-49 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image45258_062fb1-49\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"437\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-04-1024x437.jpg\" alt=\"\" class=\"kb-img wp-image-19810\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-04-1024x437.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-04-300x128.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-04-768x328.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-04-1536x655.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-04.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Method Development Considerations: Minimizing Matrix Effects<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">It is well known that electrospray ionization is prone to suppression\/enhancement effects caused by coextracted matrix interferences. These issues can be overcome by adjusting the sample preparation method towards more selective conditions, using an appropriate internal standard, and\/or adjusting the chromatographic method to resolve analytes from coeluting interferences. For this reason, after selecting the experimental conditions for the analysis of pesticides and mycotoxins in cannabis brownies, an assessment of absolute matrix effects was conducted according to the methodology proposed by Matuszewski et al. [3]. To estimate absolute matrix effects, we compared the response of all target analytes fortified in blank matrix extract versus their response in neat solvent fortified at the same concentration (15 ppb). As can be seen in Figure 5, only daminozide showed a dramatic enhancement in its response. Considering the poor retention of daminozide at the LC gradient conditions selected for this work, this pesticide is likely coeluting with multiple unretained interferences normally occurring in matrices like brownies. Based on these results, daminozide-D6 was added to the group of internal standards to specifically correct for any variations associated with daminozide\u2019s response.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5:<\/strong>\u00a0Absolute matrix effects for the LC amenable pesticides and mycotoxins.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image45258_e44956-23 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image45258_e44956-23\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"311\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-05-1024x311.jpg\" alt=\"\" class=\"kb-img wp-image-19816\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-05-1024x311.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-05-300x91.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-05-768x233.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-05-1536x466.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-05.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In addition to investigating absolute matrix effects, we assessed absolute analyte recoveries under the final method conditions. For this purpose, responses corresponding to brownie extracts obtained from samples fortified at 100 ng\/g (prior to extraction) were compared to blank brownie extracts that were then fortified (post extraction) with the same amount of analytes. As shown in Figure 6, except for daminozide, the lowest analyte recoveries were 68% for spiroxamine and ochratoxin A. Despite the multiple efforts to enhance daminozide\u2019s recovery, it was only possible to collect 30% of the originally spiked amount. This demonstrates that the best approach to obtain reliable and accurate results when analyzing pesticides and mycotoxins in cannabis brownies is using a surrogate (blank) matrix to prepare different calibration levels, and using a deuterated analogue for daminozide. The use of calibrators prepared in solvent and a lack of appropriate internal standards will likely lead to biased measurements.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 6:<\/strong>\u00a0Pesticides and mycotoxins absolute recoveries at the optimized conditions (n=3).<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image45258_21d856-c3 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image45258_21d856-c3\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"315\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-06-1024x315.jpg\" alt=\"\" class=\"kb-img wp-image-19822\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-06-1024x315.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-06-300x92.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-06-768x236.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-06-1536x472.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAN3149-06.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Method Verification Results<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Method performance for the analysis of pesticides and mycotoxins in cannabis brownies was evaluated in terms of linearity, accuracy, and precision. Summary results are presented in Table III.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Calibration curves were constructed by plotting analyte area\/internal standard area ratios versus the analyte concentrations in fortified brownie matrix standards across a range of 5\u2013700 ng\/g. A weighing factor of 1\/x was applied to all the calibration curves. The majority of compounds exhibited excellent linearity as demonstrated by R2 values of \u22650.9990 (values ranged from 0.9939 to 0.9999).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Accuracy and precision were assessed at three concentration levels that were selected to cover the linear range: low (10 ng\/g); medium (100 ng\/g); and high (500 ng\/g). Excellent results were obtained for all the target analytes because the use of standards prepared in matrix minimized matrix enhancement and suppression. Recovery values ranged from 71.2 to 116% and RSD values were all under 25%, indicating good accuracy and precision.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The majority of analytes showed LOQ values under 10 ng\/g, and it was demonstrated that the proposed methodology allows for the quantification of all the target compounds at concentrations below the action levels requested by the state of California in cannabis goods. Cyfluthrin and cypermethrin exhibited lower LOQ values via GC-MS\/MS in comparison to LC-MS\/MS; however, these two pesticides can be analyzed at the requested action levels using either of the two instrumental platforms. The LOQ for each compound was defined as the lowest concentration with a signal-to-noise ratio of at least 10, a difference of &lt;25% between the fortified concentration and the estimated concentration, and a &lt;25% replicate precision value.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Stability of the target compounds in LC extracts after 24 and 48 hours of storage in the autosampler at 10 \u2070C (n=4) was assessed relative to the peak intensities of freshly prepared samples (0 hours). Most compounds showed a change in response of less than 10% over the entire study period.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table III<\/strong>: Verification results for the optimized final method for the analysis of pesticides and mycotoxins in cannabis brownies. Results were determined by LC-MS\/MS, except for those compounds that were reported by GC-MS\/MS as indicated.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td rowspan=\"2\"><strong>Pesticide<\/strong><\/td><td rowspan=\"2\"><strong>Action Level (ng\/g) for Non-Inhalable Cannabis Goods<\/strong><\/td><td rowspan=\"2\"><strong>LOQ (ng\/g)<\/strong><\/td><td rowspan=\"2\"><strong>R<sup>2<\/sup><\/strong><\/td><td colspan=\"2\"><strong>Low QC (10 ng\/g)<\/strong><\/td><td colspan=\"2\"><strong>Medium QC (100 ng\/g)<\/strong><\/td><td colspan=\"2\"><strong>High QC (500 ng\/g)<\/strong><\/td><\/tr><tr><td><strong>Accuracy (%Recovery)<\/strong><\/td><td><strong>Precision (%RSD)<\/strong><\/td><td><strong>Accuracy (%Recovery)<\/strong><\/td><td><strong>Precision (%RSD)<\/strong><\/td><td><strong>Accuracy (%Recovery)<\/strong><\/td><td><strong>Precision (%RSD)<\/strong><\/td><\/tr><tr><td>Daminozide*<\/td><td>&lt;LOD<\/td><td>25<\/td><td>0.9954<\/td><td>\u2014<\/td><td>\u2014<\/td><td>102<\/td><td>11.7<\/td><td>92.1<\/td><td>9.73<\/td><\/tr><tr><td>Acephate<\/td><td>5000<\/td><td>10<\/td><td>0.9944<\/td><td>100<\/td><td>17.9<\/td><td>104<\/td><td>2.82<\/td><td>97.5<\/td><td>4.21<\/td><\/tr><tr><td>Thiamethoxam<\/td><td>4500<\/td><td>5<\/td><td>0.9979<\/td><td>102<\/td><td>9.77<\/td><td>106<\/td><td>1.04<\/td><td>103<\/td><td>2.14<\/td><\/tr><tr><td>Methomyl<\/td><td>100<\/td><td>5<\/td><td>0.9996<\/td><td>105<\/td><td>4.49<\/td><td>104<\/td><td>0.986<\/td><td>103<\/td><td>1.26<\/td><\/tr><tr><td>Oxamyl<\/td><td>200<\/td><td>5<\/td><td>0.9986<\/td><td>107<\/td><td>8.74<\/td><td>104<\/td><td>1.71<\/td><td>103<\/td><td>1.95<\/td><\/tr><tr><td>Imidacloprid<\/td><td>3000<\/td><td>10<\/td><td>0.9979<\/td><td>84.2<\/td><td>18.2<\/td><td>103<\/td><td>2.47<\/td><td>100<\/td><td>2.73<\/td><\/tr><tr><td>Dimethoate*<\/td><td>&lt;LOD<\/td><td>5<\/td><td>0.9994<\/td><td>103<\/td><td>4.58<\/td><td>101<\/td><td>2.72<\/td><td>101<\/td><td>3.93<\/td><\/tr><tr><td>Acetamiprid<\/td><td>5000<\/td><td>5<\/td><td>0.9991<\/td><td>105<\/td><td>7.26<\/td><td>103<\/td><td>1.00<\/td><td>100<\/td><td>2.52<\/td><\/tr><tr><td>Thiacloprid*<\/td><td>&lt;LOD<\/td><td>5<\/td><td>0.9993<\/td><td>101<\/td><td>6.48<\/td><td>106<\/td><td>2.90<\/td><td>100<\/td><td>2.19<\/td><\/tr><tr><td>Aldicarb*<\/td><td>&lt;LOD<\/td><td>5<\/td><td>0.9988<\/td><td>104<\/td><td>16.2<\/td><td>98.8<\/td><td>4.16<\/td><td>100<\/td><td>5.46<\/td><\/tr><tr><td>Naled<\/td><td>500<\/td><td>25<\/td><td>0.9962<\/td><td>\u2014<\/td><td>\u2014<\/td><td>105<\/td><td>9.83<\/td><td>103<\/td><td>1.37<\/td><\/tr><tr><td>Mevinphos I (79%)<sup>a<\/sup>*<\/td><td>&lt;LOD<\/td><td>4<\/td><td>0.9991<\/td><td>110<\/td><td>13.2<\/td><td>104<\/td><td>4.32<\/td><td>102<\/td><td>3.57<\/td><\/tr><tr><td>Mevinphos II (21%)<sup>b<\/sup>*<\/td><td>&lt;LOD<\/td><td>2<\/td><td>0.9981<\/td><td>109<\/td><td>24.0<\/td><td>106<\/td><td>5.58<\/td><td>98.3<\/td><td>5.71<\/td><\/tr><tr><td>Carbofuran*<\/td><td>&lt;LOD<\/td><td>5<\/td><td>0.9994<\/td><td>98.9<\/td><td>4.18<\/td><td>105<\/td><td>2.38<\/td><td>100<\/td><td>1.45<\/td><\/tr><tr><td>Carbaryl<\/td><td>500<\/td><td>5<\/td><td>0.9997<\/td><td>87.8<\/td><td>9.83<\/td><td>103<\/td><td>3.86<\/td><td>103<\/td><td>1.47<\/td><\/tr><tr><td>Dichlorvos*<\/td><td>100<\/td><td>5<\/td><td>0.9949<\/td><td>79.5<\/td><td>1.95<\/td><td>101<\/td><td>4.53<\/td><td>97.8<\/td><td>7.51<\/td><\/tr><tr><td>Propoxur*<\/td><td>&lt;LOD<\/td><td>5<\/td><td>0.9993<\/td><td>100<\/td><td>4.79<\/td><td>106<\/td><td>1.72<\/td><td>100<\/td><td>2.59<\/td><\/tr><tr><td>Chlorantraniliprole<\/td><td>40,000<\/td><td>10<\/td><td>0.9992<\/td><td>85.0<\/td><td>3.84<\/td><td>105<\/td><td>4.94<\/td><td>97.7<\/td><td>1.40<\/td><\/tr><tr><td>Imazalil*<\/td><td>&lt;LOD<\/td><td>5<\/td><td>0.9993<\/td><td>97.7<\/td><td>11.7<\/td><td>100<\/td><td>1.46<\/td><td>98.1<\/td><td>2.27<\/td><\/tr><tr><td>Metalaxyl<\/td><td>15,000<\/td><td>5<\/td><td>0.9996<\/td><td>101<\/td><td>8.15<\/td><td>103<\/td><td>4.11<\/td><td>101<\/td><td>2.40<\/td><\/tr><tr><td>Azoxystrobin<\/td><td>40,000<\/td><td>5<\/td><td>0.9998<\/td><td>102<\/td><td>3.39<\/td><td>103<\/td><td>0.635<\/td><td>102<\/td><td>1.04<\/td><\/tr><tr><td>Myclobutanil<\/td><td>9000<\/td><td>5<\/td><td>0.9997<\/td><td>102<\/td><td>5.95<\/td><td>104<\/td><td>4.07<\/td><td>100<\/td><td>2.89<\/td><\/tr><tr><td>Phosmet<\/td><td>200<\/td><td>5<\/td><td>0.9997<\/td><td>102<\/td><td>3.89<\/td><td>103<\/td><td>3.09<\/td><td>99.3<\/td><td>3.32<\/td><\/tr><tr><td>Spiroxamine*<\/td><td>&lt;LOD<\/td><td>5<\/td><td>0.9987<\/td><td>100<\/td><td>6.68<\/td><td>102<\/td><td>4.69<\/td><td>102<\/td><td>0.915<\/td><\/tr><tr><td>Fenoxycarb*<\/td><td>&lt;LOD<\/td><td>5<\/td><td>0.9995<\/td><td>99.2<\/td><td>2.37<\/td><td>103<\/td><td>2.24<\/td><td>100<\/td><td>2.06<\/td><\/tr><tr><td>Methiocarb*<\/td><td>&lt;LOD<\/td><td>5<\/td><td>0.9997<\/td><td>104<\/td><td>18.0<\/td><td>104<\/td><td>3.78<\/td><td>102<\/td><td>0.746<\/td><\/tr><tr><td>Spiromesifen<\/td><td>12,000<\/td><td>25<\/td><td>0.9994<\/td><td>\u2014<\/td><td>\u2014<\/td><td>103<\/td><td>5.12<\/td><td>101<\/td><td>3.39<\/td><\/tr><tr><td>Boscalid<\/td><td>10,000<\/td><td>5<\/td><td>0.9998<\/td><td>95.0<\/td><td>10.6<\/td><td>106<\/td><td>3.36<\/td><td>100<\/td><td>3.34<\/td><\/tr><tr><td>Paclobutrazol*<\/td><td>&lt;LOD<\/td><td>5<\/td><td>0.9996<\/td><td>97.3<\/td><td>13.1<\/td><td>103<\/td><td>2.94<\/td><td>97.2<\/td><td>3.49<\/td><\/tr><tr><td>Malathion<\/td><td>5000<\/td><td>5<\/td><td>0.9995<\/td><td>71.2<\/td><td>13.3<\/td><td>102<\/td><td>2.59<\/td><td>99.5<\/td><td>3.18<\/td><\/tr><tr><td>Dimethomorph I (39%)<sup>c<\/sup><\/td><td>20,000**<\/td><td>4<\/td><td>0.9994<\/td><td>85.4<\/td><td>17.9<\/td><td>101<\/td><td>5.17<\/td><td>102<\/td><td>3.41<\/td><\/tr><tr><td>Dimethomorph II (61%)<sup>d<\/sup><\/td><td>20,000**<\/td><td>3<\/td><td>0.9994<\/td><td>91.7<\/td><td>13.7<\/td><td>103<\/td><td>2.15<\/td><td>100<\/td><td>1.60<\/td><\/tr><tr><td>Tebuconazole<\/td><td>2000<\/td><td>5<\/td><td>0.9996<\/td><td>101<\/td><td>11.0<\/td><td>104<\/td><td>2.15<\/td><td>101<\/td><td>4.08<\/td><\/tr><tr><td>Bifenazate<\/td><td>5000<\/td><td>5<\/td><td>0.9999<\/td><td>111<\/td><td>6.58<\/td><td>104<\/td><td>1.97<\/td><td>100<\/td><td>3.58<\/td><\/tr><tr><td>Fenhexamid<\/td><td>10,000<\/td><td>10<\/td><td>0.9992<\/td><td>78.0<\/td><td>15.5<\/td><td>103<\/td><td>3.05<\/td><td>100<\/td><td>2.28<\/td><\/tr><tr><td>Propiconazole<\/td><td>20,000<\/td><td>5<\/td><td>0.9997<\/td><td>100<\/td><td>5.38<\/td><td>105<\/td><td>2.19<\/td><td>101<\/td><td>1.14<\/td><\/tr><tr><td>Spirotetramat<\/td><td>13,000<\/td><td>5<\/td><td>0.9990<\/td><td>101<\/td><td>13.8<\/td><td>104<\/td><td>2.04<\/td><td>101<\/td><td>4.28<\/td><\/tr><tr><td>Ethoprophos*<\/td><td>&lt;LOD<\/td><td>5<\/td><td>0.9997<\/td><td>110<\/td><td>8.84<\/td><td>103<\/td><td>1.76<\/td><td>99.5<\/td><td>2.17<\/td><\/tr><tr><td>Kresoxym-methyl<\/td><td>1000<\/td><td>5<\/td><td>0.9993<\/td><td>102<\/td><td>16.6<\/td><td>104<\/td><td>3.02<\/td><td>99.0<\/td><td>2.78<\/td><\/tr><tr><td>Spinosad- spinosyn A (71 %)<sup>e<\/sup><\/td><td>3000**<\/td><td>3.5<\/td><td>0.9994<\/td><td>97.3<\/td><td>3.95<\/td><td>102<\/td><td>2.06<\/td><td>101<\/td><td>2.62<\/td><\/tr><tr><td>Diazinon<\/td><td>200<\/td><td>5<\/td><td>0.9995<\/td><td>103<\/td><td>3.29<\/td><td>101<\/td><td>2.93<\/td><td>101<\/td><td>2.20<\/td><\/tr><tr><td>Coumaphos*<\/td><td>&lt;LOD<\/td><td>5<\/td><td>0.9997<\/td><td>101<\/td><td>5.71<\/td><td>102<\/td><td>0.739<\/td><td>97.8<\/td><td>3.02<\/td><\/tr><tr><td>Clofentezine<\/td><td>500<\/td><td>5<\/td><td>0.9997<\/td><td>99.3<\/td><td>9.11<\/td><td>103<\/td><td>2.21<\/td><td>100<\/td><td>2.62<\/td><\/tr><tr><td>Spinosad &#8211; spinosyn D (29%)<sup>f<\/sup><\/td><td>3000**<\/td><td>1.5<\/td><td>0.9990<\/td><td>103<\/td><td>9.75<\/td><td>101<\/td><td>4.37<\/td><td>97.1<\/td><td>4.99<\/td><\/tr><tr><td>Spinetoram &#8211; spinosyn J (80%)<sup>g<\/sup><\/td><td>3000**<\/td><td>4<\/td><td>0.9991<\/td><td>102<\/td><td>7.14<\/td><td>105<\/td><td>1.79<\/td><td>100<\/td><td>2.58<\/td><\/tr><tr><td>Spinetoram &#8211; spinosyn L (20%)<sup>h<\/sup><\/td><td>3000**<\/td><td>1<\/td><td>0.9991<\/td><td>97.8<\/td><td>4.45<\/td><td>100<\/td><td>3.53<\/td><td>99.1<\/td><td>1.15<\/td><\/tr><tr><td>Trifloxystrobin<\/td><td>30,000<\/td><td>5<\/td><td>0.9997<\/td><td>106<\/td><td>2.76<\/td><td>102<\/td><td>1.76<\/td><td>101<\/td><td>1.81<\/td><\/tr><tr><td>Prallethrin<\/td><td>400<\/td><td>25<\/td><td>0.9996<\/td><td>96.6<\/td><td>20.9<\/td><td>97.5<\/td><td>7.96<\/td><td>99.2<\/td><td>5.04<\/td><\/tr><tr><td>Hexythiazox<\/td><td>2000<\/td><td>5<\/td><td>0.9996<\/td><td>103<\/td><td>5.96<\/td><td>104<\/td><td>3.30<\/td><td>98.3<\/td><td>3.14<\/td><\/tr><tr><td>Cyfluthrin<\/td><td>1000<\/td><td>50<\/td><td>0.9988<\/td><td>\u2014<\/td><td>\u2014<\/td><td>107<\/td><td>6.81<\/td><td>102<\/td><td>10.5<\/td><\/tr><tr><td>Pyrethrin I (54%)<sup>i<\/sup><\/td><td>1000**<\/td><td>5.4<\/td><td>0.9998<\/td><td>92.5<\/td><td>9.14<\/td><td>104<\/td><td>1.91<\/td><td>99.2<\/td><td>1.65<\/td><\/tr><tr><td>Pyrethrin II (34%)<sup>j<\/sup><\/td><td>1000**<\/td><td>26<\/td><td>0.9990<\/td><td>\u2014<\/td><td>\u2014<\/td><td>100<\/td><td>10.9<\/td><td>98.7<\/td><td>3.44<\/td><\/tr><tr><td>Etoxazole<\/td><td>1500<\/td><td>5<\/td><td>0.9998<\/td><td>102<\/td><td>5.82<\/td><td>102<\/td><td>1.09<\/td><td>100<\/td><td>1.46<\/td><\/tr><tr><td>Piperonyl butoxide<\/td><td>8000<\/td><td>5<\/td><td>0.9998<\/td><td>103<\/td><td>4.56<\/td><td>103<\/td><td>2.45<\/td><td>101<\/td><td>3.43<\/td><\/tr><tr><td>Chlorpyrifos*<\/td><td>&lt;LOD<\/td><td>5<\/td><td>0.9994<\/td><td>98.0<\/td><td>10.2<\/td><td>101<\/td><td>3.69<\/td><td>100<\/td><td>1.93<\/td><\/tr><tr><td>Permethrin-<em>cis<\/em>&nbsp;(41%)<sup>k<\/sup><\/td><td>20,000**<\/td><td>4.1<\/td><td>0.9994<\/td><td>92.5<\/td><td>10.8<\/td><td>105<\/td><td>3.69<\/td><td>99.3<\/td><td>3.87<\/td><\/tr><tr><td>Permethrin-<em>trans<\/em>&nbsp;(59%)<sup>l<\/sup><\/td><td>20,000**<\/td><td>5.9<\/td><td>0.9999<\/td><td>116<\/td><td>5.48<\/td><td>106<\/td><td>3.61<\/td><td>97.4<\/td><td>2.75<\/td><\/tr><tr><td>(E)-Fenpyroximate<\/td><td>2000<\/td><td>5<\/td><td>0.9998<\/td><td>101<\/td><td>6.74<\/td><td>103<\/td><td>4.08<\/td><td>100<\/td><td>3.35<\/td><\/tr><tr><td>Bifenthrin<\/td><td>500<\/td><td>5<\/td><td>0.9994<\/td><td>107<\/td><td>2.93<\/td><td>103<\/td><td>4.98<\/td><td>101<\/td><td>2.07<\/td><\/tr><tr><td>AbamectinB1a<\/td><td>300<\/td><td>10<\/td><td>0.9999<\/td><td>84.9<\/td><td>20.1<\/td><td>105<\/td><td>6.26<\/td><td>101<\/td><td>3.99<\/td><\/tr><tr><td>Cypermethrin<\/td><td>1000<\/td><td>25<\/td><td>0.9991<\/td><td>\u2014<\/td><td>\u2014<\/td><td>93.3<\/td><td>6.76<\/td><td>98.8<\/td><td>7.62<\/td><\/tr><tr><td>Etofenprox*<\/td><td>&lt;LOD<\/td><td>5<\/td><td>0.9995<\/td><td>96.2<\/td><td>7.96<\/td><td>107<\/td><td>2.03<\/td><td>101<\/td><td>2.78<\/td><\/tr><tr><td>Pyridaben<\/td><td>3000<\/td><td>10<\/td><td>0.9989<\/td><td>105<\/td><td>20.7<\/td><td>101<\/td><td>5.39<\/td><td>100<\/td><td>2.48<\/td><\/tr><tr><td>Acequinocyl<\/td><td>4000<\/td><td>5<\/td><td>0.9987<\/td><td>91.1<\/td><td>11.0<\/td><td>103<\/td><td>5.47<\/td><td>104<\/td><td>4.81<\/td><\/tr><tr><td>Flonicamid<\/td><td>2000<\/td><td>10<\/td><td>0.9993<\/td><td>89.6<\/td><td>18.3<\/td><td>101<\/td><td>3.62<\/td><td>101<\/td><td>3.15<\/td><\/tr><tr><td>Fipronil*<\/td><td>&lt;LOD<\/td><td>10<\/td><td>0.9993<\/td><td>100<\/td><td>19.5<\/td><td>102<\/td><td>4.64<\/td><td>97.8<\/td><td>4.58<\/td><\/tr><tr><td>Fludioxonil<\/td><td>30,000<\/td><td>5<\/td><td>0.9995<\/td><td>109<\/td><td>11.6<\/td><td>104<\/td><td>6.13<\/td><td>99.3<\/td><td>3.39<\/td><\/tr><tr><td>Aflatoxin G2<\/td><td>20**<\/td><td>5<\/td><td>0.9987<\/td><td>102<\/td><td>19.1<\/td><td>104<\/td><td>2.74<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><tr><td>Aflatoxin G1<\/td><td>20**<\/td><td>5<\/td><td>0.9984<\/td><td>116<\/td><td>11.2<\/td><td>96.4<\/td><td>1.20<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><tr><td>Aflatoxin B2<\/td><td>20**<\/td><td>5<\/td><td>0.9996<\/td><td>105<\/td><td>10.4<\/td><td>98.7<\/td><td>1.77<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><tr><td>Ochratoxin A<\/td><td>20<\/td><td>10<\/td><td>0.9943<\/td><td>91.1<\/td><td>11.5<\/td><td>112<\/td><td>10.6<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><tr><td>Aflatoxin B1<\/td><td>20**<\/td><td>5<\/td><td>0.9990<\/td><td>106<\/td><td>11.4<\/td><td>96.0<\/td><td>3.23<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><tr><td>Captan<sup>\u2020<\/sup><\/td><td>5000<\/td><td>10<\/td><td>0.9941<\/td><td>112<\/td><td>14.8<\/td><td>103<\/td><td>5.25<\/td><td>108<\/td><td>5.28<\/td><\/tr><tr><td>Chlordane<sup>\u2020<\/sup>*<\/td><td>&lt;LOD<\/td><td>25<\/td><td>0.9939<\/td><td>\u2014<\/td><td>\u2014<\/td><td>106<\/td><td>5.32<\/td><td>93.6<\/td><td>4.60<\/td><\/tr><tr><td>Chlorfenapyr<sup>\u2020<\/sup>*<\/td><td>&lt;LOD<\/td><td>25<\/td><td>0.9953<\/td><td>\u2014<\/td><td>\u2014<\/td><td>102<\/td><td>3.19<\/td><td>99.2<\/td><td>4.95<\/td><\/tr><tr><td>Methyl parathion<sup>\u2020<\/sup>*<\/td><td>&lt;LOD<\/td><td>5<\/td><td>0.9976<\/td><td>103<\/td><td>6.59<\/td><td>103<\/td><td>1.83<\/td><td>92.7<\/td><td>5.22<\/td><\/tr><tr><td>Pentachloronitrobenzene<sup>\u2020<\/sup><\/td><td>200<\/td><td>5<\/td><td>0.9975<\/td><td>98.2<\/td><td>9.75<\/td><td>103<\/td><td>3.76<\/td><td>100<\/td><td>4.45<\/td><\/tr><tr><td>Cyfluthrin<sup>\u2020<\/sup><\/td><td>1000<\/td><td>5<\/td><td>0.9983<\/td><td>108<\/td><td>9.27<\/td><td>103<\/td><td>4.10<\/td><td>103<\/td><td>3.26<\/td><\/tr><tr><td>Cypermethrin<sup>\u2020<\/sup><\/td><td>1000<\/td><td>10<\/td><td>0.9986<\/td><td>103<\/td><td>12.3<\/td><td>103<\/td><td>2.13<\/td><td>102<\/td><td>1.97<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><sup>\u2020<\/sup>Reported results were determined by GC-MS\/MS.<br><sup>*<\/sup>Category I pesticides, LOQ is \u2264100 ng\/g<br>**Action level is the total concentration of both isomers together.<br>Results are calculated based on relative contribution of each isomer to the overall fortification levels as follows:<br><sup>a<\/sup>Mevinphos I: low: 8 ng\/g; medium: 79 ng\/g; high: 395 ng\/g<br><sup>b<\/sup>Menvinphos II: low: 2 ng\/g; medium: 21 ng\/g; high: 105 ng\/g<br><sup>c<\/sup>Dimethomorph I: low: 4 ng\/g; medium: 39 ng\/g; high: 195 ng\/g<br><sup>d<\/sup>Dimethomorph II: low: 6 ng\/g; medium: 61 ng\/g; high: 305 ng\/g<br><sup>e<\/sup>Spinosad- spinosyn A: low: 7 ng\/g; medium: 71 ng\/g; high: 355 ng\/g<br><sup>f<\/sup>Spinosad &#8211; spinosyn D: low: 3 ng\/g; medium: 29 ng\/g; high: 145 ng\/g<br><sup>g<\/sup>Spinetoram &#8211; spinosyn J: low: 8 ng\/g; medium: 80 ng\/g; high: 400 ng\/g<br><sup>h<\/sup>Spinetoram &#8211; spinosyn L: low: 2 ng\/g; medium: 20 ng\/g; high: 100 ng\/g<br><sup>i<\/sup>Pyrethrin I: low: 5 ng\/g; medium: 54 ng\/g; high: 270 ng\/g<br><sup>j<\/sup>Pyrethrin II: low: 3 ng\/g; medium: 34 ng\/g; high: 170 ng\/g<br><sup>k<\/sup>Permethrin-<em>cis<\/em>: low: 4 ng\/g; medium: 41 ng\/g; high: 205 ng\/g<br><sup>l<\/sup>Permethrin-<em>trans<\/em>: low: 6 ng\/g; medium: 59 ng\/g; high: 295 ng\/g<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">An effective workflow for the analysis of pesticides and mycotoxins in cannabis brownies was developed and optimization strategies were detailed in order to provide a starting point for similar matrices. LC-MS\/MS and GC-MS\/MS amenable compounds were all extracted using acidified acetonitrile and then cleaned up using C18 SPE cartridges. GC-MS\/MS samples required an additional dSPE cleanup with magnesium sulfate and PSA. The use of acidified acetonitrile was proven to be crucial in the recovery of analytes such as daminozide, spiroxamine, and ochratoxin A. Excellent results in terms of LOQ values, linearity, accuracy, and precision were attained for all the target compounds. Since this methodology only uses 3 mL of extraction solvent per sample, a significant reduction in solvent usage\/waste is also possible. Extracts showed acceptable stability even after 48 hours in the LC autosampler.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns has-background is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\" style=\"background-color:#e4f7fa\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<h3 class=\"wp-block-heading has-text-color has-link-color wp-elements-1489b0bd8c7fa6a213f7f4f1cf134d8f\" style=\"color:#02366d\">Want even better performance when analyzing mycotoxins and other metal-sensitive compounds?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Learn more at&nbsp;<a href=\"https:\/\/www.restek.com\/articles\/accurately-analyze-metal-sensitive-compounds-with-resteks-new-inert-lc-columns\" target=\"_blank\" rel=\"noopener\">www.restek.com\/inert<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\"><div class=\"wp-block-image\">\n<figure class=\"alignright size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"123\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-lc-columns-inert-lc-02.png\" alt=\"\" class=\"wp-image-29764\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-lc-columns-inert-lc-02.png 400w, https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-product-lc-columns-inert-lc-02-300x92.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">References<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Text of Regulations, Bureau of Cannabis Control, California Code of Regulations,&nbsp;<a href=\"https:\/\/cannabis.ca.gov\/wp-content\/uploads\/sites\/13\/2019\/01\/Order-of-Adoption-Clean-Version-of-Text.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/cannabis.ca.gov\/wp-content\/uploads\/sites\/13\/2019\/01\/Order-of-Adoption-Clean-Version-of-Text.pdf<\/a>, (accessed 8 November 2019).<\/li>\n\n\n\n<li>Quantification of residues of folpet and captan in QuEChERS extracts, EU Reference Laboratories for Residues of Pesticides,&nbsp;<a href=\"http:\/\/www.eurl-pesticides.eu\/userfiles\/file\/EurlSRM\/meth_CaptanFolpet_EurlSRM.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">http:\/\/www.eurl-pesticides.eu\/userfiles\/file\/EurlSRM\/meth_CaptanFolpet_EurlSRM.pdf<\/a>, (accessed 7 November 2019).<\/li>\n\n\n\n<li>B. K. Matuszewski, M. L. Constanzer, C. M. Chavez-Eng, Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC\u2212MS\/MS, Anal. Chem. 75 (2003) 3019\u20133030.&nbsp;<a href=\"https:\/\/pubs.acs.org\/doi\/10.1021\/ac020361s\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/pubs.acs.org\/doi\/10.1021\/ac020361s<\/a><\/li>\n<\/ol>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Produits mentionn\u00e9s<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24654\">                                R\u00e9f. 24654                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Flacon \u00e0 visser WISP 48 avec syst\u00e8me Step et zone de marquage gradu\u00e9e, 4.0\u00a0ml, 15 x 45\u00a0mm, filetage 13-425 (flacon seulement), transparent, lot de 100<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24654\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26030\">                                R\u00e9f. 26030                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Cartouches Resprep C18 pour extraction SPE, tubes en polypropyl\u00e8ne avec fritt\u00e9s en poly\u00e9thyl\u00e8ne, 1\u00a0ml\/100 mg, lot de 100<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26030\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26215\">                                R\u00e9f. 26215                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Tube QuEChERS Q-sep pour purification d\u2019extraits par dSPE, 2 ml, pour centrifugation, contenant 150\u00a0mg de MgSO4, 25\u00a0mg de PSA, lot de 100<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26215\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9314A12\">                                R\u00e9f. 9314A12                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Colonnes Raptor ARC-18, 2,7\u00b5m 100 mm x 2.1 mm DI<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9314A12\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13423\">                                R\u00e9f. 13423                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Colonne capillaire Rxi-5ms, L 30\u00a0m, DI 0.25 mm, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/13423\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23447\">                                R\u00e9f. 23447                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Insert Topaz Gooseneck, 4.0\u00a0mm x 6.5 x 78.5, pour GC Thermo TRACE 1300\/1310, 1600\/1610 avec injecteur SSL, avec laine de quartz, d\u00e9sactivation Premium, lot de 5<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23447\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Government regulations in California require the cannabis industry to test edible products for an extensive list of pesticides and mycotoxins. Here, an effective workflow for this complex analysis was developed in brownies, and optimization strategies are detailed in order to provide a starting point for similar matrices. Both LC-MS\/MS and GC-MS\/MS were employed and excellent results for LOQ, linearity, accuracy, and precision were attained for all the target compounds.<\/p>\n","protected":false},"author":32,"featured_media":6835,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[13],"tags":[],"industries-application":[2173,2191,2193,2175],"post-badge":[],"resource-type":[],"product-library":[2407,2408,2416,2420,2427,2409,2435,2410,2411,2438,2441],"resource-technique":[2307,2310,2361,2366,2313],"ppma_author":[603,452],"class_list":["post-45258","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes","industries-application-cannabis-zh","industries-application-food-beverage-zh","industries-application-food-safety-zh","industries-application-medical-recreational-cannabis-zh","product-library-air-gas-sampling-products-zh","product-library-gas-chromatography-products-zh","product-library-gas-standards-accessories-zh","product-library-gc-columns-zh","product-library-lc-columns-zh","product-library-liquid-chromatography-products-zh","product-library-liquid-reference-standards-zh","product-library-reference-standard-products-zh","product-library-sample-preparation-products-zh","product-library-spe-sle-zh","product-library-vials-accessories-zh","resource-technique-gas-chromatography-gc-zh","resource-technique-liquid-chromatography-zh","resource-technique-ms-ms-zh","resource-technique-quechers-zh","resource-technique-solid-phase-extraction-spe-zh"],"acf":[],"taxonomy_info":{"category":[{"value":13,"label":"Application Notes"}],"industries-application":[{"value":2173,"label":"\u5927\u9ebb"},{"value":2191,"label":"\u98df\u54c1\u548c\u996e\u6599"},{"value":2193,"label":"\u98df\u54c1\u5b89\u5168"},{"value":2175,"label":"\u533b\u7597\u6216\u5a31\u4e50\u7528\u5927\u9ebb"}],"product-library":[{"value":2407,"label":"\u7a7a\u6c14\u548c\u6c14\u4f53\u91c7\u6837\u4ea7\u54c1"},{"value":2408,"label":"\u6c14\u76f8\u8272\u8c31\u76f8\u5173\u4ea7\u54c1"},{"value":2416,"label":"\u6807\u6c14\u548c\u914d\u4ef6"},{"value":2420,"label":"GC\u8272\u8c31\u67f1"},{"value":2427,"label":"LC\u8272\u8c31\u67f1"},{"value":2409,"label":"\u6db2\u76f8\u8272\u8c31\u76f8\u5173\u4ea7\u54c1"},{"value":2435,"label":"\u6db2\u4f53\u53c2\u8003\u6807\u51c6\u54c1"},{"value":2410,"label":"\u53c2\u8003\u6807\u51c6\u54c1"},{"value":2411,"label":"\u6837\u54c1\u524d\u5904\u7406\u4ea7\u54c1"},{"value":2438,"label":"SPE\u548cSLE"},{"value":2441,"label":"\u6837\u54c1\u74f6\u548c\u914d\u4ef6"}],"resource-technique":[{"value":2307,"label":"\u6c14\u76f8\u8272\u8c31\uff08GC\uff09"},{"value":2310,"label":"\u6db2\u76f8\u8272\u8c31"},{"value":2361,"label":"MS\/MS"},{"value":2366,"label":"QuEChERS"},{"value":2313,"label":"\u56fa\u76f8\u8403\u53d6"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-FFAN3149-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Colton Myers","author_link":"https:\/\/discover.restek.com\/fr\/author\/colton-myers\/"},"comment_info":0,"category_info":[{"term_id":13,"name":"Application Notes","slug":"application-notes","term_group":0,"term_taxonomy_id":13,"taxonomy":"category","description":"","parent":0,"count":88,"filter":"raw","cat_ID":13,"category_count":88,"category_description":"","cat_name":"Application Notes","category_nicename":"application-notes","category_parent":0}],"tag_info":false,"authors":[{"term_id":603,"user_id":0,"is_guest":1,"slug":"nathaly-reyes-garces-phd","display_name":"Nathaly Reyes-Garc\u00e9s, PhD","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Nathaly","last_name":"Reyes-Garc\u00e9s","user_url":"","job_title":"","description":""},{"term_id":452,"user_id":32,"is_guest":0,"slug":"colton-myers","display_name":"Colton Myers","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg"},"author_category":"1","first_name":"Colton","last_name":"Myers","user_url":"https:\/\/www.linkedin.com\/in\/myerscolton\/","job_title":"Product Manager - New Product Development","description":"Colton Myers is a Product Manager for GC columns at Restek Corporation with over 10 years of experience in research and development. He specializes in driving new GC column technologies from concept to market, combining deep technical expertise with a strong focus on innovation and commercialization. Colton holds a BS in chemistry from Juniata College and a Master of Management in Corporate Innovation and Entrepreneurship from Penn State University."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/45258","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/32"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=45258"}],"version-history":[{"count":12,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/45258\/revisions"}],"predecessor-version":[{"id":85564,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/45258\/revisions\/85564"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/6835"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=45258"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=45258"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=45258"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=45258"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=45258"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=45258"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=45258"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=45258"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=45258"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}