{"id":45289,"date":"2025-10-08T17:56:41","date_gmt":"2025-10-08T17:56:41","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/simplified-spe-for-pfas-analysis-of-non-potable-waters\/"},"modified":"2026-08-11T15:00:59","modified_gmt":"2026-08-11T15:00:59","slug":"simplified-spe-for-pfas-analysis-of-non-potable-waters","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/application-notes\/evan4369\/simplified-spe-for-pfas-analysis-of-non-potable-waters","title":{"rendered":"Simplified SPE for PFAS Analysis of Non-Potable Waters"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Abstract<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">PFAS analysis in nondrinking water matrices presents unique challenges to sample preparation. Trace-level analysis of PFAS in surface water and wastewater requires both low background contamination and the ability to handle challenging matrices. Resprep PFAS cartridges allow fast, reliable SPE sample preparation of non-potable waters, such as those covered in EPA Method 1633 for PFAS analysis. The inclusion of both WAX and carbon layers in a single cartridge allows for simultaneous extraction and cleanup. In addition, an optional filter aid prevents the cartridges from clogging when preparing samples that contain high amounts of suspended solids.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Introduction<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">While methods for PFAS analysis in drinking water have been widely used for some time, the absence of methods for non-potable waters using solid-phase extraction (SPE) has led many labs to modify drinking water methods when analyzing surface water and wastewater. To address this, EPA Method 1633 [1], which was finalized in January of 2024, provides a sample preparation approach that includes an SPE extraction using a weak anion exchange (WAX) cartridge manually packed with glass wool and a dispersive carbon cleanup. The manual packing of glass wool and separate carbon cleanup step add extra time, complexity, and risk of introducing contaminants to the sample preparation process, and manually packed wool can increase variation among technicians. Labs interested in streamlining their sample preparation workflows can utilize Resprep PFAS cartridges, which are dual-bed SPE cartridges that contain both WAX and carbon sorbent beds that allow the SPE extraction and carbon cleanup to be accomplished in a single cartridge. An optional filter aid eliminates the need for manual addition of glass wool to handle samples containing solids, and it provides much better performance in preventing clogs.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Experimental<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Sample Preparation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Samples for precision, accuracy, and method detection limit (MDL) studies were prepared in polypropylene bottles using 500 mL deionized water spiked with 25 \u00b5L of extracted internal standards (EIS, Wellington Laboratories p\/n MPFAC-HIF-ES) as per EPA Method 1633, Section 11.2.4. Four samples for precision and recovery analysis were spiked with 200 \u00b5L of native PFAS standards (Wellington Laboratories p\/n EPA-1633STK), giving pre-extraction concentrations of 100-2500 ng\/L. Seven MDL samples were spiked with 20 \u00b5L of a 20:1 dilution of the native standard, giving pre-extraction concentrations of 0.5-12.5 ng\/L. Seven blank replicates were prepared for the MDL study as well. The MDL samples were prepared and analyzed over three days.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Resprep PFAS SPE cartridges (6 mL), which contained 150 mg of 30 \u00b5m WAX and 50 mg of CarboPrep Plus carbon (cat.#&nbsp;28930), were placed on a Thermo AutoTrace PFAS system. After preparation of the samples and setup of the SPE system, the samples were extracted following the instructions in EPA Method 1633, Section 11.4, which is summarized in Figure 1. After extraction, the extracts were spiked with 25 \u00b5L of non-extracted internal standards (NIS, Wellington Laboratories p\/n MPFAC-HIF-IS).<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> Sample Preparation Procedure for EPA Method 1633 PFAS Analysis<br><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image45289_9e3423-88 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image45289_9e3423-88\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"865\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evan4369-UNV-01-1024x865.jpg\" alt=\"\" class=\"kb-img wp-image-24028\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evan4369-UNV-01-1024x865.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evan4369-UNV-01-300x253.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evan4369-UNV-01-768x649.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evan4369-UNV-01-1536x1297.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evan4369-UNV-01.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\">Samples to test filter aid efficiency were prepared using ASTM substitute wastewater [2] diluted by 2.5x to be ~100 mg\/L suspended solids. Resprep PFAS SPE cartridges (cat.#&nbsp;28931), which contained 2000 mg of filter aid, 150 mg of 30 \u00b5m WAX, and 50 mg of CarboPrep Plus carbon, were placed on a Resprep QR-12 vacuum manifold (cat.# 28298-VM) that was fitted with quick-replace liners (cat.# 28310-VM). Resprep sample delivery system lines (cat.# 26250) were used to transfer the samples to the SPE cartridges. Five hundred milliliters of the substitute wastewater was loaded onto the cartridge. The volume of sample that passed through without clogging was compared to cartridges containing only WAX (cat.# 28292) and WAX cartridges manually packed with glass wool (cat.# 24324) to half the height of the SPE cartridge as described in Method 1633, Section 12.1.1.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Analytical System<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">After extraction, the samples were analyzed by LC-MS\/MS under the conditions shown below. The use of a PFAS delay column is important to prevent any PFAS contamination upstream of the injector from coeluting with the samples. Thorough blank checking of the analytical system was performed and showed no detectable PFAS contamination.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Instrument Conditions for EPA Method 1633 PFAS Analysis<\/strong><br>System: Waters ACQUITY Premier LC\/Xevo TQ Absolute Triple Quadrupole MS<br>Columns:<br>\u2022 PFAS delay column (cat.# 27854)<br>\u2022 Analytical column: Force C18, 1.8 \u00b5m x 50 mm x 2.1 mm (cat.# 9634252)<br>Injection volume: 3 \u00b5L<br>Mobile phase A: Water, 5 mM ammonium acetate<br>Mobile phase B: Methanol<br>Flow rate: 0.4 mL\/min<br>Temperature: 40 \u00b0C<br>Gradient:<\/p>\n\n\n<figure class=\"wp-block-table\">\n<table style=\"border-style: none; width: auto;\">\n<tbody>\n<tr>\n<td><strong>Time (min)<\/strong><\/td>\n<td><strong>%B<\/strong><\/td>\n<\/tr>\n<tr>\n<td>0<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<td>6.6<\/td>\n<td>95<\/td>\n<\/tr>\n<tr>\n<td>6.61<\/td>\n<td>20<\/td>\n<\/tr>\n<tr>\n<td>7.5<\/td>\n<td>20<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<p class=\"wp-block-paragraph\">Ion source: Electrospray<br>Ion mode: ESI-<br>Mode: MRM<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The analytical system was calibrated using the concentrations shown in Table 4 of Method 1633 for PFAS analysis. Curve fits were chosen that minimized % relative standard error (%RSE).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Method Detection Limits (MDL)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The method detection limit was calculated from the analysis of seven blank replicates and seven low-level spikes, as outlined in EPA\u2019s Definition and Procedure for the Determination of the Method Detection Limit, Revision 2 [3]. The standard deviations of the spike and blank results were multiplied by the Student\u2019s <em>t<\/em>-value of 3.143 to determine the MDL, and the higher of the results between the spikes and blanks was selected as the MDL.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Accuracy and Precision<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Accuracy and precision were determined by analyzing four replicate spikes. The accuracy of the spikes was calculated and compared to the recovery limits in Table 5 of EPA Method 1633. The relative standard deviations of the spike results were also determined and compared to the limits in Table 5. The recovery of the isotope dilution standards was calculated from the spike replicates and compared to the &nbsp;recovery limits from Table 6 of EPA Method 1633 for PFAS analysis.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Results and Discussion<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Method Performance Verification Experiment<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Good chromatographic results were obtained for all compounds, as shown in Figure 2. The MDL, blank levels, accuracy, and precision results for native PFAS analytes are shown in Table I. The calculated MDLs were below the reporting limits shown in Table 9 in EPA Method 1633, and the accuracy of the spikes ranged from 77 to 125% of the spiked value, meeting the requirements in Table 5 of Method 1633. The spikes showed good precision as well, with the results being \u226425% RSD. Similarly, the recoveries for the isotope dilution standards were also within the limits listed in Table 6 of the method. The results are shown in Table II.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> Recovery Standard for EPA Method 1633 PFAS Analysis<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0599.png\" alt=\"EPA Method 1633 PFAS on Force C18 (50 x 2.1 mm) Extracted with Resprep PFAS SPE\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0599<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/L)<\/th><th style=\"text-align: center;width: 75px\">Precursor 1<\/th><th style=\"text-align: center;width: 75px\">Product 1<\/th><th style=\"text-align: center;width: 75px\">Product 2<\/th><th style=\"text-align: center;width: 75px\">Precursor 2<\/th><th style=\"text-align: center;width: 75px\">Product 1<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2,3,4- 13C3]butanoic acid (13C3-PFBA)<\/td><td class=\"oth\">1.485<\/td><td class=\"oth\">5<\/td><td class=\"oth\">216<\/td><td class=\"oth\">172<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2,3,4- 13C4]butanoic acid (13C4-PFBA)<\/td><td class=\"oth\">1.487<\/td><td class=\"oth\">10<\/td><td class=\"oth\">217<\/td><td class=\"oth\">172<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorobutanoic acid (PFBA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-22-4\/Perfluorobutanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorobutanoic acid (PFBA)<\/a><\/td><td class=\"oth\">1.489<\/td><td class=\"oth\">10<\/td><td class=\"oth\">213<\/td><td class=\"oth\">169<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoro-3-methoxypropanoic acid (PFMPA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/377-73-1\/Perfluoro-3-methoxypropanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluoro-3-methoxypropanoic acid (PFMPA)<\/a><\/td><td class=\"oth\">2.007<\/td><td class=\"oth\">5<\/td><td class=\"oth\">229<\/td><td class=\"oth\">85<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\">3-Perfluoropropyl propanoic acid (3:3FTCA)<\/td><td class=\"oth\">2.7<\/td><td class=\"oth\">12.5<\/td><td class=\"oth\">241<\/td><td class=\"oth\">177<\/td><td class=\"oth\">117<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2,3,4,5- 13C5]pentanoic acid (13C5-PFPeA)<\/td><td class=\"oth\">2.765<\/td><td class=\"oth\">5<\/td><td class=\"oth\">268<\/td><td class=\"oth\">223<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoropentanoic acid (PFPeA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2706-90-3\/Perfluoropentanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluoropentanoic acid (PFPeA)<\/a><\/td><td class=\"oth\">2.768<\/td><td class=\"oth\">5<\/td><td class=\"oth\">263<\/td><td class=\"oth\">219<\/td><td class=\"oth\">69<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\">Perfluorobutane sulfonate (PFBS)<\/td><td class=\"oth\">3.006<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">299<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\">Sodium perfluoro-1-[2,3,4- 13C3]butanesulfonate (13C3-PFBS)<\/td><td class=\"oth\">3.007<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">302<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\">Perfluoro-4-methoxybutanoic acid (PFMBA)<\/td><td class=\"oth\">3.071<\/td><td class=\"oth\">5<\/td><td class=\"oth\">279<\/td><td class=\"oth\">85<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoro(2-ethoxyethane)sulfonic acid (PFEESA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/113507-82-7\/Perfluoro(2-ethoxyethane)sulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluoro(2-ethoxyethane)sulfonic acid (PFEESA)<\/a><\/td><td class=\"oth\">3.333<\/td><td class=\"oth\">5<\/td><td class=\"oth\">315<\/td><td class=\"oth\">135<\/td><td class=\"oth\">83<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\">Nonafluoro-3,6-dioxaheptanoic acid (NFDHA)<\/td><td class=\"oth\">3.493<\/td><td class=\"oth\">5<\/td><td class=\"oth\">295<\/td><td class=\"oth\">201<\/td><td class=\"oth\">85<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\">1<i>H<\/i>,1<i>H<\/i>,2<i>H<\/i>,2<i>H<\/i>-perfluorohexane sulfonate (4:2 FTS)<\/td><td class=\"oth\">3.545<\/td><td class=\"oth\">10<\/td><td class=\"oth\">327<\/td><td class=\"oth\">307<\/td><td class=\"oth\">81<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\">Sodium 1<i>H<\/i>,1<i>H<\/i>,2<i>H<\/i>,2<i>H<\/i>-perfluoro-1-[1,2- 13C2]hexane sulfonate (13C2-4:2FTS)<\/td><td class=\"oth\">3.55<\/td><td class=\"oth\">5<\/td><td class=\"oth\">329<\/td><td class=\"oth\">81<\/td><td class=\"oth\">309<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorohexanoic acid (PFHxA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/307-24-4\/Perfluorohexanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorohexanoic acid (PFHxA)<\/a><\/td><td class=\"oth\">3.608<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">313<\/td><td class=\"oth\">269<\/td><td class=\"oth\">119<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2,3,4,6- 13C2]hexanoic acid (13C2-PFHxA)<\/td><td class=\"oth\">3.609<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">315<\/td><td class=\"oth\">270<\/td><td class=\"oth\">119<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2,3,4,6- 13C5]hexanoic acid (13C5-PFHxA)<\/td><td class=\"oth\">3.61<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">318<\/td><td class=\"oth\">273<\/td><td class=\"oth\">120<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\">Perfluoropentane sulfonate (PFPeS)<\/td><td class=\"oth\">3.718<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">349<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\">2,3,3,3-Tetrafluoro-2-(1,1,2,2,3,3,3-heptafluoropropoxy13C3-propanoic acid (13C3-HFPO-DA)<\/td><td class=\"oth\">3.79<\/td><td class=\"oth\">10<\/td><td class=\"oth\">287<\/td><td class=\"oth\">169<\/td><td class=\"oth\">185<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexafluoropropylene oxide (HFPO-DA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13252-13-6\/Hexafluoropropylene oxide\" target=\"_blank\" rel=\"noopener\">Hexafluoropropylene oxide (HFPO-DA)<\/a><\/td><td class=\"oth\">3.795<\/td><td class=\"oth\">10<\/td><td class=\"oth\">285<\/td><td class=\"oth\">169<\/td><td class=\"oth\">185<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoroheptanoic acid (PFHpA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-85-9\/Perfluoroheptanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluoroheptanoic acid (PFHpA)<\/a><\/td><td class=\"oth\">4.174<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">363<\/td><td class=\"oth\">319<\/td><td class=\"oth\">169<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2,3,4- 13C4]heptanoic acid (13C4-PFHpA)<\/td><td class=\"oth\">4.174<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">367<\/td><td class=\"oth\">322<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\">Perfluoro-1-hexane[18O2]sulfonic acid (18O2-PFHxS)<\/td><td class=\"oth\">4.218<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">403<\/td><td class=\"oth\">84<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\">Sodium perfluoro-1-[1,2,3- 13C3]hexanesulfonate (13C3-PFHxS)<\/td><td class=\"oth\">4.218<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">402<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\">Perfluorohexane sulfonate (PFHxS)<\/td><td class=\"oth\">4.22<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">399<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\">&lt;a class=&quot;cmpd_link&quot; title=&quot;View compound information for 4,8-Dioxa-3<i>H<\/i>-perfluorononanoic acid (ADONA)&#8221; title=&#8221;View compound information for 4,8-Dioxa-3<i>H<\/i>-perfluorononanoic acid (ADONA)&#8221; href=&#8221;https:\/\/ez.restek.com\/compound\/view\/en\/919005-14-4\/4,8-Dioxa-3<i>H-perfluorononanoic acid&#8221;&gt;4,8-Dioxa-3<i>H<\/i>-perfluorononanoic acid (ADONA)<\/a><\/td><td class=\"oth\">4.232<\/td><td class=\"oth\">10<\/td><td class=\"oth\">377<\/td><td class=\"oth\">251<\/td><td class=\"oth\">85<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\">2<i>H<\/i>,2<i>H<\/i>,3<i>H<\/i>,3<i>H<\/i>-Perfluorooctanoic acid (5:3FTCA)<\/td><td class=\"oth\">4.247<\/td><td class=\"oth\">62.5<\/td><td class=\"oth\">341<\/td><td class=\"oth\">237<\/td><td class=\"oth\">217<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\">1<i>H<\/i>,1<i>H<\/i>,2<i>H<\/i>,2<i>H<\/i>-perfluorooctane sulfonate (6:2 FTS)<\/td><td class=\"oth\">4.58<\/td><td class=\"oth\">10<\/td><td class=\"oth\">427<\/td><td class=\"oth\">407<\/td><td class=\"oth\">81<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">29.<\/td><td class=\"cmpd\">Sodium 1<i>H<\/i>,1<i>H<\/i>,2<i>H<\/i>,2<i>H<\/i>-perfluoro-1-[1,2-13C2]-octane sulfonate (13C2-6:2FTS)<\/td><td class=\"oth\">4.581<\/td><td class=\"oth\">5<\/td><td class=\"oth\">429<\/td><td class=\"oth\">81<\/td><td class=\"oth\">409<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">30.<\/td><td class=\"cmpd\">Perfluoro-n-[ 13C8]octanoic acid (13C8-PFOA)<\/td><td class=\"oth\">4.598<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">421<\/td><td class=\"oth\">376<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">31.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorooctanoic acid (PFOA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/335-67-1\/Perfluorooctanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorooctanoic acid (PFOA)<\/a><\/td><td class=\"oth\">4.601<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">413<\/td><td class=\"oth\">369<\/td><td class=\"oth\">169<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">32.<\/td><td class=\"cmpd\">Perfluoro-n-[ 13C4]octanoic acid (13C4-PFOA)<\/td><td class=\"oth\">4.601<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">417<\/td><td class=\"oth\">172<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">33.<\/td><td class=\"cmpd\">Perfluoroheptane sulfonate (PFHpS)<\/td><td class=\"oth\">4.621<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">449<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">34.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorononanoic acid (PFNA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/375-95-1\/Perfluorononanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorononanoic acid (PFNA)<\/a><\/td><td class=\"oth\">4.944<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">463<\/td><td class=\"oth\">419<\/td><td class=\"oth\">219<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">35.<\/td><td class=\"cmpd\">Perfluoro-n-[ 13C5]nonanoic acid (13C5-PFNA)<\/td><td class=\"oth\">4.944<\/td><td class=\"oth\">1.25<\/td><td class=\"oth\">468<\/td><td class=\"oth\">423<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">36.<\/td><td class=\"cmpd\">Perfluoro-n-[ 13C9]nonanoic acid (13C9-PFNA)<\/td><td class=\"oth\">4.944<\/td><td class=\"oth\">1.25<\/td><td class=\"oth\">472<\/td><td class=\"oth\">427<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">37.<\/td><td class=\"cmpd\">Perfluorooctane sulfonate (PFOS)<\/td><td class=\"oth\">4.949<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">499<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">38.<\/td><td class=\"cmpd\">Sodium perfluoro-[ 13C4]octanesulfonate (13C4-PFOS)<\/td><td class=\"oth\">4.95<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">503<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">39.<\/td><td class=\"cmpd\">Sodium perfluoro-[ 13C8]octanesulfonate (13C8-PFOS)<\/td><td class=\"oth\">4.95<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">507<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">40.<\/td><td class=\"cmpd\">3-Perfluoroheptyl propanoic acid (7:3FTCA)<\/td><td class=\"oth\">5.046<\/td><td class=\"oth\">62.5<\/td><td class=\"oth\">441<\/td><td class=\"oth\">317<\/td><td class=\"oth\">337<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">41.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 9-Chlorohexadecafluoro-3-oxanonane-1-sulfonic acid (9Cl-PF3ONS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/756426-58-1\/9-Chlorohexadecafluoro-3-oxanonane-1-sulfonic acid\" target=\"_blank\" rel=\"noopener\">9-Chlorohexadecafluoro-3-oxanonane-1-sulfonic acid (9Cl-PF3ONS)<\/a><\/td><td class=\"oth\">5.114<\/td><td class=\"oth\">10<\/td><td class=\"oth\">531<\/td><td class=\"oth\">351<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">533<\/td><td class=\"oth\">353<\/td><\/tr>\n<tr><td class=\"num\">42.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorodecanoic acid (PFDA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/335-76-2\/Perfluorodecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorodecanoic acid (PFDA)<\/a><\/td><td class=\"oth\">5.237<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">513<\/td><td class=\"oth\">469<\/td><td class=\"oth\">219<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">43.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2,3,4,5,6- 13C2]decanoic acid (13C2-PFDA)<\/td><td class=\"oth\">5.237<\/td><td class=\"oth\">1.25<\/td><td class=\"oth\">515<\/td><td class=\"oth\">470<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">44.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2,3,4,5,6- 13C6]decanoic acid (13C6-PFDA)<\/td><td class=\"oth\">5.237<\/td><td class=\"oth\">1.25<\/td><td class=\"oth\">519<\/td><td class=\"oth\">474<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">45.<\/td><td class=\"cmpd\">1<i>H<\/i>,1<i>H<\/i>,2<i>H<\/i>,2<i>H<\/i>-perfluorodecane sulfonate (8:2 FTS)<\/td><td class=\"oth\">5.238<\/td><td class=\"oth\">10<\/td><td class=\"oth\">527<\/td><td class=\"oth\">507<\/td><td class=\"oth\">81<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">46.<\/td><td class=\"cmpd\">Sodium 1<i>H<\/i>,1<i>H<\/i>,2<i>H<\/i>,2<i>H<\/i>-perfluoro-1-[1,2- 13C2]-decane sulfonate (13C2-8:2FTS)<\/td><td class=\"oth\">5.238<\/td><td class=\"oth\">5<\/td><td class=\"oth\">529<\/td><td class=\"oth\">81<\/td><td class=\"oth\">509<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">47.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorononanesulfonic acid (PFNS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/68259-12-1\/Perfluorononanesulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorononanesulfonic acid (PFNS)<\/a><\/td><td class=\"oth\">5.239<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">549<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">48.<\/td><td class=\"cmpd\">N-methyl-d 3-perfluoro-1-octanesulfonamidoacetic acid (D3-NMeFOSAA)<\/td><td class=\"oth\">5.361<\/td><td class=\"oth\">5<\/td><td class=\"oth\">573<\/td><td class=\"oth\">419<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">49.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2355-31-9\/N-methyl perfluorooctanesulfonamidoacetic acid\" target=\"_blank\" rel=\"noopener\">N-methyl perfluorooctanesulfonamidoacetic acid (NMeFOSAA)<\/a><\/td><td class=\"oth\">5.366<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">570<\/td><td class=\"oth\">419<\/td><td class=\"oth\">483<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">50.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorodecanesulfonic acid (PFDS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/335-77-3\/Perfluorodecanesulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorodecanesulfonic acid (PFDS)<\/a><\/td><td class=\"oth\">5.475<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">599<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">51.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluoroundecanoic acid (PFUnA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2058-94-8\/Perfluoroundecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluoroundecanoic acid (PFUnA)<\/a><\/td><td class=\"oth\">5.486<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">563<\/td><td class=\"oth\">519<\/td><td class=\"oth\">269<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">52.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2,3,4,5,6,7- 13C7]undecanoic acid (13C7-PFUnA)<\/td><td class=\"oth\">5.486<\/td><td class=\"oth\">1.25<\/td><td class=\"oth\">570<\/td><td class=\"oth\">525<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">53.<\/td><td class=\"cmpd\">N-ethyl-d 5-perfluoro-1-octanesulfonamidoacetic acid (D5-NEtFOSAA)<\/td><td class=\"oth\">5.487<\/td><td class=\"oth\">5<\/td><td class=\"oth\">589<\/td><td class=\"oth\">419<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">54.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2991-50-6\/N-ethyl perfluorooctanesulfonamidoacetic acid\" target=\"_blank\" rel=\"noopener\">N-ethyl perfluorooctanesulfonamidoacetic acid (NEtFOSAA)<\/a><\/td><td class=\"oth\">5.487<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">584<\/td><td class=\"oth\">419<\/td><td class=\"oth\">526<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">55.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/763051-92-9\/11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid\" target=\"_blank\" rel=\"noopener\">11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid (11Cl-PF3OUdS)<\/a><\/td><td class=\"oth\">5.59<\/td><td class=\"oth\">10<\/td><td class=\"oth\">631<\/td><td class=\"oth\">451<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">633<\/td><td class=\"oth\">453<\/td><\/tr>\n<tr><td class=\"num\">56.<\/td><td class=\"cmpd\">Perfluorooctanesulfonamide (PFOSA)<\/td><td class=\"oth\">5.669<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">498<\/td><td class=\"oth\">78<\/td><td class=\"oth\">478<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">57.<\/td><td class=\"cmpd\">Perfluoro-1-[ 13C8]octanesulfonamide (13C8-PFOSA)<\/td><td class=\"oth\">5.669<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">506<\/td><td class=\"oth\">78<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">58.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorododecanoic acid (PFDoA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/307-55-1\/Perfluorododecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorododecanoic acid (PFDoA)<\/a><\/td><td class=\"oth\">5.691<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">613<\/td><td class=\"oth\">569<\/td><td class=\"oth\">319<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">59.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2- 13C2]dodecanoic acid (13C2-PFDoA)<\/td><td class=\"oth\">5.692<\/td><td class=\"oth\">1.25<\/td><td class=\"oth\">615<\/td><td class=\"oth\">570<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">60.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorododecanesulfonic acid (PFDoS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/79780-39-5\/Perfluorododecanesulfonic acid\" target=\"_blank\" rel=\"noopener\">Perfluorododecanesulfonic acid (PFDoS)<\/a><\/td><td class=\"oth\">5.861<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">699<\/td><td class=\"oth\">80<\/td><td class=\"oth\">99<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">61.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorotridecanoic acid (PFTrDA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72629-94-8\/Perfluorotridecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorotridecanoic acid (PFTrDA)<\/a><\/td><td class=\"oth\">5.876<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">663<\/td><td class=\"oth\">619<\/td><td class=\"oth\">169<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">62.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perfluorotetradecanoic acid (PFTeDA)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/376-06-7\/Perfluorotetradecanoic acid\" target=\"_blank\" rel=\"noopener\">Perfluorotetradecanoic acid (PFTeDA)<\/a><\/td><td class=\"oth\">6.031<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">713<\/td><td class=\"oth\">669<\/td><td class=\"oth\">169<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">63.<\/td><td class=\"cmpd\">Perfluoro-n-[1,2- 13C2]tetradecanoic acid (13C2-PFTeDA)<\/td><td class=\"oth\">6.031<\/td><td class=\"oth\">1.25<\/td><td class=\"oth\">715<\/td><td class=\"oth\">670<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">64.<\/td><td class=\"cmpd\">N-methyl perfluorooctanesulfonamide (NMeFOSA)<\/td><td class=\"oth\">6.158<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">512<\/td><td class=\"oth\">219<\/td><td class=\"oth\">169<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">65.<\/td><td class=\"cmpd\">N-methyl-D 3-perfluoro-1-octanesulfonamide (D3-NMeFOSA)<\/td><td class=\"oth\">6.159<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">515<\/td><td class=\"oth\">219<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">66.<\/td><td class=\"cmpd\">N-methyl perfluorooctanesulfonamidoethanol (NMeFOSE)<\/td><td class=\"oth\">6.166<\/td><td class=\"oth\">25<\/td><td class=\"oth\">616<\/td><td class=\"oth\">59<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">67.<\/td><td class=\"cmpd\">N-methyl-D 7-perfluorooctanesulfonamidoethanol (D7-NMeFOSE)<\/td><td class=\"oth\">6.167<\/td><td class=\"oth\">25<\/td><td class=\"oth\">623<\/td><td class=\"oth\">59<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">68.<\/td><td class=\"cmpd\">N-ethyl-D 5-perfluoro-1-octanesulfonamide (D5-NEtFOSA)<\/td><td class=\"oth\">6.295<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">531<\/td><td class=\"oth\">219<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">69.<\/td><td class=\"cmpd\">N-ethyl perfluorooctanesulfonamide (NEtFOSA)<\/td><td class=\"oth\">6.296<\/td><td class=\"oth\">2.5<\/td><td class=\"oth\">526<\/td><td class=\"oth\">219<\/td><td class=\"oth\">169<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">70.<\/td><td class=\"cmpd\">N-ethyl perfluorooctanesulfonamidoethanol (NEtFOSE)<\/td><td class=\"oth\">6.298<\/td><td class=\"oth\">25<\/td><td class=\"oth\">630<\/td><td class=\"oth\">59<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">71.<\/td><td class=\"cmpd\">N-ethyl-D 9-perfluorooctanesulfonamidoethanol (D9-NEtFOSE)<\/td><td class=\"oth\">6.298<\/td><td class=\"oth\">25<\/td><td class=\"oth\">639<\/td><td class=\"oth\">59<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Force C18  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9634252\" rel=\"noopener\">cat.# 9634252<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>50 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>1.8 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>100 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>3 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 5 mM ammonium acetate  <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.4<\/td><td>80<\/td><td>20<\/td><\/tr><tr><td>6<\/td><td>0.4<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>6.6<\/td><td>0.4<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>6.61<\/td><td>0.4<\/td><td>80<\/td><td>20<\/td><\/tr><tr><td>7.5<\/td><td>0.4<\/td><td>80<\/td><td>20<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Max Pressure:<\/th><td>~400 bar<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Waters Xevo TQ-S<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Waters ACQUITY Premier<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Resprep PFAS cartridges (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/28930\" rel=\"noopener\">cat.# 28930<\/a>) and a Thermo AutoTrace PFAS instrument were used for the following sample preparation procedure.<br \/>1. Spike 500 mL DI water with 200 \u00b5L of Wellington EPA-1633STK and 25 \u00b5L of Wellington MPFAC-HIF-ES.<br \/>2. Rinse cartridge with 15 mL of 1% ammonium hydroxide in methanol.<br \/>3. Rinse with 5 mL of 0.3 M formic acid in water.<br \/>4. Load sample onto SPE cartridge dropwise at 5 mL\/min.<br \/>5. Rinse bottle with 5 mL DI water, load onto SPE cartridge dropwise at 5 mL\/min, repeat.<br \/>6. Rinse bottle with 5 mL of 1:1 0.1 M formic acid:methanol and load onto SPE cartridge dropwise at 5 mL\/min.<br \/>7. Flow nitrogen through cartridge for 15 minutes.<br \/>8. Rinse bottles with 5 mL of 1% ammonium hydroxide in methanol, elute into collection vessel.<br \/>9. Add 25 \u00b5L of concentrated acetic acid and 25 \u00b5L of Wellington MPFAC-HIF-IS.<br \/>10. Transfer aliquot to autosampler vial (cat. # 23243) and cap (cat. # 23244).<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>A PFAS delay column (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/27854\" rel=\"noopener\">cat.# 27854<\/a>) was installed before the injector.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9634252<\/li><li>27854<\/li><li>28930<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>pfas-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0599.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> Results from MDL, Blank, Precision, and Accuracy Experiments for Native PFAS<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Compound<\/strong><\/td><td><strong>Abbreviation<\/strong><\/td><td><strong>MDL (ng\/L)<\/strong><\/td><td><strong>Blank (ng\/L)*<\/strong><\/td><td><strong>Accuracy (%)<\/strong><\/td><td><strong>%RSD<\/strong><\/td><\/tr><tr><td>Perfluorobutanoic acid<\/td><td>PFBA<\/td><td>0.34<\/td><td>ND<\/td><td>112<\/td><td>5<\/td><\/tr><tr><td>Perfluoro-3-methoxypropanoic acid<\/td><td>PFMPA<\/td><td>0.20<\/td><td>ND<\/td><td>109<\/td><td>6<\/td><\/tr><tr><td>3-Perfluoropropyl propanoic acid<\/td><td>3:3FTCA<\/td><td>0.31<\/td><td>ND<\/td><td>95<\/td><td>6<\/td><\/tr><tr><td>Perfluoropentanoic acid<\/td><td>PFPeA<\/td><td>0.26<\/td><td>ND<\/td><td>111<\/td><td>6<\/td><\/tr><tr><td>Perfluorobutane sulfonate<\/td><td>PFBS<\/td><td>0.19<\/td><td>ND<\/td><td>101<\/td><td>5<\/td><\/tr><tr><td>Perfluoro-4-methoxybutanoic acid<\/td><td>PFMBA<\/td><td>0.18<\/td><td>ND<\/td><td>111<\/td><td>6<\/td><\/tr><tr><td>Perfluoro(2-ethoxyethane)sulfonic acid<\/td><td>PFEESA<\/td><td>0.15<\/td><td>ND<\/td><td>94<\/td><td>5<\/td><\/tr><tr><td>Nonafluoro-3,6-dioxaheptanoic acid<\/td><td>NFDHA<\/td><td>0.46<\/td><td>ND<\/td><td>121<\/td><td>5<\/td><\/tr><tr><td>1<em>H<\/em>,1<em>H<\/em>,2<em>H<\/em>,2<em>H<\/em>-perfluorohexane sulfonate<\/td><td>4:2 FTS<\/td><td>0.36<\/td><td>ND<\/td><td>104<\/td><td>5<\/td><\/tr><tr><td>2<em>H<\/em>,2<em>H<\/em>,3<em>H<\/em>,3<em>H<\/em>-Perfluorooctanoic acid<\/td><td>5:3FTCA<\/td><td>1.48<\/td><td>ND<\/td><td>102<\/td><td>6<\/td><\/tr><tr><td>Perfluorohexanoic acid<\/td><td>PFHxA<\/td><td>0.08<\/td><td>ND<\/td><td>113<\/td><td>5<\/td><\/tr><tr><td>Perfluoropentane sulfonate<\/td><td>PFPeS<\/td><td>0.07<\/td><td>ND<\/td><td>122<\/td><td>4<\/td><\/tr><tr><td>Hexafluoropropylene oxide dimer acid<\/td><td>HFPO-DA<\/td><td>0.40<\/td><td>ND<\/td><td>114<\/td><td>12<\/td><\/tr><tr><td>Perfluoroheptanoic acid<\/td><td>PFHpA<\/td><td>0.08<\/td><td>ND<\/td><td>109<\/td><td>5<\/td><\/tr><tr><td>Perfluorohexane sulfonate<\/td><td>PFHxS<\/td><td>0.07<\/td><td>ND<\/td><td>104<\/td><td>7<\/td><\/tr><tr><td>4,8-Dioxa-3<em>H<\/em>-perfluorononanoic acid<\/td><td>ADONA<\/td><td>0.39<\/td><td>ND<\/td><td>99<\/td><td>9<\/td><\/tr><tr><td>1<em>H<\/em>,1<em>H<\/em>,2<em>H<\/em>,2<em>H<\/em>-perfluorooctane sulfonate<\/td><td>6:2 FTS<\/td><td>0.37<\/td><td>ND<\/td><td>107<\/td><td>4<\/td><\/tr><tr><td>3-Perfluoroheptyl propanoic acid<\/td><td>7:3FTCA<\/td><td>2.32<\/td><td>ND<\/td><td>100<\/td><td>6<\/td><\/tr><tr><td>Perfluoroheptane sulfonate<\/td><td>PFHpS<\/td><td>0.76<\/td><td>ND<\/td><td>121<\/td><td>8<\/td><\/tr><tr><td>Perfluorooctanoic acid<\/td><td>PFOA<\/td><td>0.32<\/td><td>ND<\/td><td>104<\/td><td>2<\/td><\/tr><tr><td>Perfluorooctane sulfonate<\/td><td>PFOS<\/td><td>0.20<\/td><td>ND<\/td><td>112<\/td><td>7<\/td><\/tr><tr><td>Perfluorooctanesulfonamide<\/td><td>PFOSA<\/td><td>0.21<\/td><td>ND<\/td><td>81<\/td><td>11<\/td><\/tr><tr><td>Perfluorononanoic acid<\/td><td>PFNA<\/td><td>0.08<\/td><td>ND<\/td><td>114<\/td><td>5<\/td><\/tr><tr><td><em>N<\/em>-methyl perfluorooctanesulfonamide<\/td><td>NMeFOSA<\/td><td>0.07<\/td><td>ND<\/td><td>104<\/td><td>13<\/td><\/tr><tr><td>9-Chlorohexadecafluoro-3-oxanonane-1-sulfonic acid<\/td><td>9Cl-PF3ONS<\/td><td>0.61<\/td><td>ND<\/td><td>85<\/td><td>11<\/td><\/tr><tr><td>Perfluorononanesulfonic acid<\/td><td>PFNS<\/td><td>0.25<\/td><td>ND<\/td><td>79<\/td><td>7<\/td><\/tr><tr><td>Perfluorodecanoic acid<\/td><td>PFDA<\/td><td>0.18<\/td><td>ND<\/td><td>117<\/td><td>8<\/td><\/tr><tr><td><em>N<\/em>-ethyl perfluorooctanesulfonamide<\/td><td>NEtFOSA<\/td><td>0.14<\/td><td>ND<\/td><td>112<\/td><td>15<\/td><\/tr><tr><td>1<em>H<\/em>,1<em>H<\/em>,2<em>H<\/em>,2<em>H<\/em>-perfluorodecane sulfonate<\/td><td>8:2 FTS<\/td><td>0.91<\/td><td>ND<\/td><td>113<\/td><td>11<\/td><\/tr><tr><td>Perfluoroundecanoic acid<\/td><td>PFUnA<\/td><td>0.26<\/td><td>ND<\/td><td>125<\/td><td>12<\/td><\/tr><tr><td><em>N<\/em>-methyl perfluorooctanesulfonamidoacetic acid<\/td><td>NMeFOSAA<\/td><td>0.15<\/td><td>ND<\/td><td>95<\/td><td>12<\/td><\/tr><tr><td><em>N<\/em>-ethyl perfluorooctanesulfonamidoacetic acid<\/td><td>NEtFOSAA<\/td><td>0.23<\/td><td>ND<\/td><td>93<\/td><td>12<\/td><\/tr><tr><td>Perfluorodecanesulfonic acid<\/td><td>PFDS<\/td><td>0.25<\/td><td>ND<\/td><td>94<\/td><td>23<\/td><\/tr><tr><td>11-Chloroeicosafluoro-3-oxaundecane-1-sulfonic acid<\/td><td>11Cl-PF3OUdS<\/td><td>0.56<\/td><td>ND<\/td><td>77<\/td><td>25<\/td><\/tr><tr><td>Perfluorododecanoic acid<\/td><td>PFDoA<\/td><td>0.27<\/td><td>ND<\/td><td>118<\/td><td>15<\/td><\/tr><tr><td><em>N<\/em>-methyl perfluorooctanesulfonamidoethanol<\/td><td>NMeFOSE<\/td><td>1.11<\/td><td>ND<\/td><td>106<\/td><td>9<\/td><\/tr><tr><td><em>N<\/em>-ethyl perfluorooctanesulfonamidoethanol<\/td><td>NEtFOSE<\/td><td>1.10<\/td><td>ND<\/td><td>111<\/td><td>9<\/td><\/tr><tr><td>Perfluorotridecanoic acid<\/td><td>PFTrDA<\/td><td>0.33<\/td><td>ND<\/td><td>108<\/td><td>15<\/td><\/tr><tr><td>Perfluorododecanesulfonic acid<\/td><td>PFDoS<\/td><td>0.13<\/td><td>ND<\/td><td>89<\/td><td>12<\/td><\/tr><tr><td>Perfluorotetradecanoic acid<\/td><td>PFTeDA<\/td><td>0.32<\/td><td>ND<\/td><td>102<\/td><td>23<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*ND = Not detected above MDL<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table II:<\/strong>&nbsp;Results from Precision and Accuracy Experiments for Isotope Dilution Standards<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Compound<\/strong><\/td><td><strong>Abbreviation<\/strong><\/td><td><strong>Accuracy (%)<\/strong><\/td><td><strong>%RSD<\/strong><\/td><\/tr><tr><td>Perfluoro-<em>n<\/em>-[1,2,3,4- 13C4]butanoic acid<\/td><td>13C4-PFBA<\/td><td>88<\/td><td>4<\/td><\/tr><tr><td>Perfluoro-<em>n<\/em>-[1,2,3,4,5- 13C5]pentanoic acid<\/td><td>13C5-PFPeA<\/td><td>88<\/td><td>5<\/td><\/tr><tr><td>Sodium perfluoro-1-[2,3,4- 13C3]butanesulfonate<\/td><td>13C3-PFBS<\/td><td>97<\/td><td>3<\/td><\/tr><tr><td>Sodium 1<em>H<\/em>,1<em>H<\/em>,2<em>H<\/em>,2<em>H<\/em>-perfluoro-1-[1,2- 13C2]hexane sulfonate<\/td><td>13C2-4:2FTS<\/td><td>95<\/td><td>8<\/td><\/tr><tr><td>Perfluoro-<em>n<\/em>-[1,2,3,4,6- 13C5]hexanoic acid<\/td><td>13C5-PFHxA<\/td><td>122<\/td><td>2<\/td><\/tr><tr><td>2,3,3,3-Tetrafluoro-2-(1,1,2,2,3,3,3-heptafluoropropoxy13C3-propanoic acid<\/td><td>13C3-HFPO-DA<\/td><td>92<\/td><td>4<\/td><\/tr><tr><td>Perfluoro-<em>n<\/em>-[1,2,3,4- 13C4]heptanoic acid<\/td><td>13C4-PFHpA<\/td><td>107<\/td><td>4<\/td><\/tr><tr><td>Sodium perfluoro-1-[1,2,3- 13C3]hexanesulfonate<\/td><td>13C3-PFHxS<\/td><td>102<\/td><td>4<\/td><\/tr><tr><td>Sodium 1<em>H<\/em>,1<em>H<\/em>,2<em>H<\/em>,2<em>H<\/em>-perfluoro-1-[1,2-13C2]-octane sulfonate<\/td><td>13C2-6:2FTS<\/td><td>83<\/td><td>5<\/td><\/tr><tr><td>Perfluoro-<em>n<\/em>-[ 13C8]octanoic acid<\/td><td>13C8-PFOA<\/td><td>106<\/td><td>5<\/td><\/tr><tr><td>Sodium perfluoro-[ 13C8]octanesulfonate<\/td><td>13C8-PFOS<\/td><td>77<\/td><td>7<\/td><\/tr><tr><td>Perfluoro-1-[ 13C8]octanesulfonamide<\/td><td>13C8-PFOSA<\/td><td>94<\/td><td>11<\/td><\/tr><tr><td><em>N<\/em>-methyl-d 3-perfluoro-1-octanesulfonamidoacetic acid<\/td><td>D3-NMeFOSAA<\/td><td>85<\/td><td>9<\/td><\/tr><tr><td><em>N<\/em>-ethyl-d 5-perfluoro-1-octanesulfonamidoacetic acid<\/td><td>D5-NEtFOSAA<\/td><td>87<\/td><td>11<\/td><\/tr><tr><td>Perfluoro-<em>n<\/em>-[ 13C9]nonanoic acid<\/td><td>13C9-PFNA<\/td><td>83<\/td><td>7<\/td><\/tr><tr><td>Perfluoro-<em>n<\/em>-[1,2,3,4,5,6- 13C6]decanoic acid<\/td><td>13C6-PFDA<\/td><td>80<\/td><td>7<\/td><\/tr><tr><td>Sodium 1<em>H<\/em>,1<em>H<\/em>,2<em>H<\/em>,2<em>H<\/em>-perfluoro-1-[1,2- 13C2]-decane sulfonate<\/td><td>13C2-8:2FTS<\/td><td>84<\/td><td>5<\/td><\/tr><tr><td><em>N<\/em>-methyl-D 7-perfluorooctanesulfonamidoethanol<\/td><td>D7-NMeFOSE<\/td><td>108<\/td><td>13<\/td><\/tr><tr><td><em>N<\/em>-ethyl-D 9-perfluorooctanesulfonamidoethanol<\/td><td>D9-NEtFOSE<\/td><td>88<\/td><td>17<\/td><\/tr><tr><td><em>N<\/em>-methyl-D 3-perfluoro-1-octanesulfonamide<\/td><td>D3-NMeFOSA<\/td><td>84<\/td><td>8<\/td><\/tr><tr><td><em>N<\/em>-ethyl-D 5-perfluoro-1-octanesulfonamide<\/td><td>D5-NEtFOSA<\/td><td>111<\/td><td>10<\/td><\/tr><tr><td>Perfluoro-<em>n<\/em>-[1,2,3,4,5,6,7- 13C7]undecanoic acid<\/td><td>13C7-PFUnA<\/td><td>78<\/td><td>13<\/td><\/tr><tr><td>Perfluoro-<em>n<\/em>-[1,2- 13C2]dodecanoic acid<\/td><td>13C2-PFDoA<\/td><td>45<\/td><td>24<\/td><\/tr><tr><td>Perfluoro-<em>n<\/em>-[1,2- 13C2]tetradecanoic acid<\/td><td>13C2-PFTeDA<\/td><td>36<\/td><td>21<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Filtration and Sample Flow Experiment<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Resprep PFAS SPE cartridges are available with and without a factory-packed filter aid that allows faster, more consistent sample preparation compared to using manually packed glass wool. As demonstrated in Figure 3, the filter aid provides another significant benefit: it prevents clogging so that the full sample can be processed, saving the time, effort, and cost of a second extraction. In this comparison, only the Resprep PFAS cartridge with filter aid allowed for extraction of the full 500 mL of the substitute wastewater matrix containing 100 mg\/L suspended solids. This is a great improvement over the use of glass wool, which could extract less than half of the sample, and WAX alone, which could extract less than a tenth of the sample.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong>\u00a0Results from Filtration and Sample Flow Experiment<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image45289_368826-23 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image45289_368826-23\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"487\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evan4369-UNV-03-1024x487.jpg\" alt=\"\" class=\"kb-img wp-image-24034\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evan4369-UNV-03-1024x487.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evan4369-UNV-03-300x143.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evan4369-UNV-03-768x365.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-evan4369-UNV-03.jpg 1144w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusions<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Nondrinking water matrices present unique challenges to labs using SPE sample preparation. Resprep PFAS cartridges allows labs to handle difficult water matrices more efficiently while meeting or exceeding the requirements of EPA Method 1633 for PFAS analysis. Visit&nbsp;<a href=\"https:\/\/www.restek.com\/PFAS\" target=\"_blank\" rel=\"noopener\">www.restek.com\/PFAS<\/a>&nbsp;for additional products, methods, and technical resources.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">References<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>U.S. Environmental Protection Agency, Method 1633, Analysis of per- and polyfluoroalkyl substances (PFAS) in aqueous, solid, biosolids, and tissue samples by LC-MS\/MS, January 2024.&nbsp;<a href=\"https:\/\/cfpub.epa.gov\/si\/si_public_record_report.cfm?Lab=CESER&amp;dirEntryId=356428\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/cfpub.epa.gov\/si\/si_public_record_report.cfm?Lab=CESER&amp;dirEntryId=356428<\/a> <\/li>\n\n\n\n<li>ASTM International, D5905-98(2018), Standard practice for the preparation of substitute wastewater, December 2018.&nbsp;<a href=\"https:\/\/www.astm.org\/d5905-98r18.html\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.astm.org\/d5905-98r18.html<\/a><\/li>\n\n\n\n<li>U.S. Environmental Protection Agency, Definition and procedure for the determination of the method detection limit, Revision 2, December 2016.&nbsp;<a href=\"https:\/\/www.epa.gov\/sites\/default\/files\/2016-12\/documents\/mdl-procedure_rev2_12-13-2016.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.epa.gov\/sites\/default\/files\/2016-12\/documents\/mdl-procedure_rev2_12-13-2016.pdf<\/a><\/li>\n<\/ol>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Produits mentionn\u00e9s<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">                                R\u00e9f. 27854                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">\u201cColonne-retard\u201d PFAS HPLC, 5 \u00b5m, 50 x 2.1 mm<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9634252\">                                R\u00e9f. 9634252                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Colonne LC Force C18, 1,8 \u03bcm 50 mm x 2.1 mm<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9634252\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28930\">                                R\u00e9f. 28930                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Cartouches SPE Resprep PFAS, 6 ml, 150 mg WAX\/50 mg GCB, pack de 30<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28930\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28931\">                                R\u00e9f. 28931                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Cartouches SPE Resprep PFAS avec &quot;Filter Aid&quot;, 6 ml, 2000 mg Filter Aid\/150 mg WAX\/50 mg GCB, pack de 30<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28931\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28298-VM\">                                R\u00e9f. 28298-VM                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Manifold sous-vide Resprep QR-12<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28298-VM\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28310-VM\">                                R\u00e9f. 28310-VM                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Insert jetable Quick-Replace, PTFE, pour module d&#039;extraction sous-vide Resprep QR, lot de 100<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28310-VM\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26250\">                                R\u00e9f. 26250                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Syst\u00e8me d&#039;alimentation Resprep, lot de 6<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26250\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28292\">                                R\u00e9f. 28292                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Cartouche SPE Polym\u00e9rique Resprep WAX, 6ml\/200mg, 30\u03bcm, pack de 30<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28292\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24324\">                                R\u00e9f. 24324                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Laine de verre d\u00e9sactiv\u00e9e, 10g<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24324\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div class=\"wp-block-group hub-fullwidth-container has-theme-palette-9-background-color has-background\" style=\"margin-top:0px;margin-bottom:0px;padding-top:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><style>.kadence-column102266_b11f32-a2 > .kt-inside-inner-col{padding-top:45px;padding-right:0px;padding-bottom:45px;padding-left:0px;}.kadence-column102266_b11f32-a2 > .kt-inside-inner-col,.kadence-column102266_b11f32-a2 > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column102266_b11f32-a2 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column102266_b11f32-a2 > .kt-inside-inner-col{flex-direction:column;}.kadence-column102266_b11f32-a2 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column102266_b11f32-a2 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column102266_b11f32-a2{position:relative;}@media all and (max-width: 1024px){.kadence-column102266_b11f32-a2 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column102266_b11f32-a2 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column102266_b11f32-a2 hub-guttered-centered-container\"><div class=\"kt-inside-inner-col\"><style>.kb-row-layout-id102266_d863fc-6c > .kt-row-column-wrap{align-content:start;}:where(.kb-row-layout-id102266_d863fc-6c > .kt-row-column-wrap) > .wp-block-kadence-column{justify-content:start;}.kb-row-layout-id102266_d863fc-6c > .kt-row-column-wrap{column-gap:var(--global-kb-gap-md, 2rem);row-gap:var(--global-kb-gap-md, 2rem);padding-top:20px;padding-right:20px;padding-bottom:20px;padding-left:20px;grid-template-columns:minmax(0, 1fr);}.kb-row-layout-id102266_d863fc-6c{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;overflow:clip;isolation:isolate;}.kb-row-layout-id102266_d863fc-6c > .kt-row-layout-overlay{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;}.kb-row-layout-id102266_d863fc-6c > .kt-row-layout-overlay{opacity:0.30;}@media all and (max-width: 1024px){.kb-row-layout-id102266_d863fc-6c > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}@media all and (max-width: 767px){.kb-row-layout-id102266_d863fc-6c > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}<\/style><div class=\"kb-row-layout-wrap kb-row-layout-id102266_d863fc-6c alignnone wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-1-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<style>.kadence-column102266_19753c-12 > .kt-inside-inner-col,.kadence-column102266_19753c-12 > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column102266_19753c-12 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column102266_19753c-12 > .kt-inside-inner-col{flex-direction:column;}.kadence-column102266_19753c-12 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column102266_19753c-12 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column102266_19753c-12{position:relative;}@media all and (max-width: 1024px){.kadence-column102266_19753c-12 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column102266_19753c-12 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column102266_19753c-12\"><div class=\"kt-inside-inner-col\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-1024x1024.png\" alt=\"Icon depicting customer service person.\" class=\"wp-image-95744\" style=\"width:100px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-1024x1024.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-300x300.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-150x150.png 150w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-768x768.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic.png 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73, .wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73[data-kb-block=\"kb-adv-heading102266_a727d9-73\"]{margin-top:20px;text-align:center;font-size:48px;line-height:55px;font-weight:400;font-style:normal;font-family:'Open Sans';}.wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73, .wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73[data-kb-block=\"kb-adv-heading102266_a727d9-73\"] .kb-adv-text-inner{background-image:linear-gradient(270deg,rgb(4,137,214) 0%,rgb(1,94,155) 100%);background-clip:text;-webkit-box-decoration-break:clone;box-decoration-break:clone;-webkit-background-clip:text;-webkit-text-fill-color:transparent;}.wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73[data-kb-block=\"kb-adv-heading102266_a727d9-73\"] mark.kt-highlight{font-style:normal;-webkit-text-fill-color:initial !important;-webkit-background-clip:initial !important;background-clip:initial !important;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73[data-kb-block=\"kb-adv-heading102266_a727d9-73\"] img.kb-inline-image{width:150px;vertical-align:baseline;}@media all and (max-width: 1024px){.wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73, .wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73[data-kb-block=\"kb-adv-heading102266_a727d9-73\"]{font-size:40px;}}@media all and (max-width: 767px){.wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73, .wp-block-kadence-advancedheading.kt-adv-heading102266_a727d9-73[data-kb-block=\"kb-adv-heading102266_a727d9-73\"]{font-size:36px;}}<\/style><h2 class=\"kt-adv-heading102266_a727d9-73 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading102266_a727d9-73\"><span class=\"kb-adv-text-inner\">Vous avez besoin d&#8217;aide pour vos analyses de PFAS ?<\/span><\/h2>\n\n\n<p class=\"has-text-align-center has-17-font-size has-theme-palette-3-color has-text-color has-link-color wp-elements-0f9554f869ba8e476de5a9f6c3cd3d4c wp-block-paragraph\" style=\"padding-right:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);font-size:23px\">De la s\u00e9lection de la m\u00e9thode aux recommandations de produits, nos experts PFAS vous accompagnent pour d\u00e9velopper vos protocoles complexes et obtenir des r\u00e9sultats fiables et pr\u00e9cis.<\/p>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns102266_ef75ca-34{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns102266_ef75ca-34 .kt-button{font-weight:normal;font-style:normal;}.kt-btns102266_ef75ca-34 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns102266_ef75ca-34 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns102266_ef75ca-34 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns102266_ef75ca-34 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns102266_ef75ca-34 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns102266_ef75ca-34 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns102266_ef75ca-34 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns102266_ef75ca-34\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn102266_2ad5bb-ba.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn102266_2ad5bb-ba.kb-button{color:var(--global-palette9, #ffffff);background:#61b522;font-size:var(--global-kb-font-size-md, 1.25rem);border-top-left-radius:10px;border-top-right-radius:10px;border-bottom-right-radius:10px;border-bottom-left-radius:10px;border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}.kb-btn102266_2ad5bb-ba.kb-button .kb-svg-icon-wrap{color:var(--global-palette9, #ffffff);}.kb-btn102266_2ad5bb-ba.kb-button:hover .kb-svg-icon-wrap, .kb-btn102266_2ad5bb-ba.kb-button:focus .kb-svg-icon-wrap{color:#61b522;}.wp-block-kadence-advancedbtn .kb-btn102266_2ad5bb-ba.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn102266_2ad5bb-ba.kb-button:focus{color:#61b522;background:var(--global-palette9, #ffffff);border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn102266_2ad5bb-ba.kb-button{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn102266_2ad5bb-ba.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn102266_2ad5bb-ba.kb-button:focus{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}@media all and (max-width: 767px){.wp-block-kadence-advancedbtn .kb-btn102266_2ad5bb-ba.kb-button{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}.wp-block-kadence-advancedbtn .kb-btn102266_2ad5bb-ba.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn102266_2ad5bb-ba.kb-button:focus{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}<\/style><a class=\"kb-button kt-button button kb-btn102266_2ad5bb-ba kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-true wp-block-kadence-singlebtn\" href=\"https:\/\/explore.restek.com\/PFAS-FR\" target=\"_blank\" rel=\"noopener\"><span class=\"kt-btn-inner-text\"><strong>Contactez un expert PFAS<\/strong><\/span><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_arrowRight kt-btn-icon-side-right\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg><\/span><\/a><\/div>\n<\/div><\/div>\n\n<\/div><\/div><\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>This application note demonstrates how Resprep PFAS cartridges can help labs streamline SPE sample preparation for the analysis of PFAS in non-potable waters.<\/p>\n","protected":false},"author":27,"featured_media":6571,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[13],"tags":[2782],"industries-application":[2163,2161,2165,2668],"post-badge":[],"resource-type":[],"product-library":[2375,2402],"resource-technique":[2299,2302,2304],"ppma_author":[447],"class_list":["post-45289","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes","tag-pfas","industries-application-drinking-water-wastewater-testing","industries-application-environmental","industries-application-pfas-testing","industries-application-semivolatiles","product-library-sample-preparation-products","product-library-spe-sle","resource-technique-liquid-chromatography","resource-technique-ms-ms","resource-technique-solid-phase-extraction-spe"],"acf":[],"taxonomy_info":{"category":[{"value":13,"label":"Application Notes"}],"post_tag":[{"value":2782,"label":"PFAS"}],"industries-application":[{"value":2163,"label":"Drinking Water &amp; Wastewater Testing"},{"value":2161,"label":"Environmental"},{"value":2165,"label":"PFAS Testing"},{"value":2668,"label":"Semivolatiles"}],"product-library":[{"value":2375,"label":"Sample Preparation Products"},{"value":2402,"label":"SPE &amp; SLE"}],"resource-technique":[{"value":2299,"label":"Liquid Chromatography"},{"value":2302,"label":"MS\/MS"},{"value":2304,"label":"Solid-Phase Extraction (SPE)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVAN4369-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Jason Hoisington","author_link":"https:\/\/discover.restek.com\/fr\/author\/jason-hoisington\/"},"comment_info":0,"category_info":[{"term_id":13,"name":"Application Notes","slug":"application-notes","term_group":0,"term_taxonomy_id":13,"taxonomy":"category","description":"","parent":0,"count":88,"filter":"raw","cat_ID":13,"category_count":88,"category_description":"","cat_name":"Application Notes","category_nicename":"application-notes","category_parent":0}],"tag_info":[{"term_id":2782,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2782,"taxonomy":"post_tag","description":"","parent":0,"count":124,"filter":"raw"}],"authors":[{"term_id":447,"user_id":27,"is_guest":0,"slug":"jason-hoisington","display_name":"Jason Hoisington","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hoisington-jason-01.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hoisington-jason-01.jpg"},"author_category":"1","first_name":"Jason","last_name":"Hoisington","user_url":"https:\/\/www.linkedin.com\/in\/jason-hoisington-73067653\/","job_title":"Principal Scientist, Sample Preparation","description":"Jason Hoisington received his bachelor\u2019s degree in general science with a focus on chemistry from the University of Alaska, Fairbanks. He worked for SGS Environmental for seven years in environmental soil and water testing, developing methods for the analysis of volatiles and semivolatile organics to include pesticides and polychlorinated biphenyls (PCBs). In 2012, Jason moved on to lab and application support for Dow Chemical Company, providing advanced analytical troubleshooting and method development. In 2019, Jason joined Restek and has focused on air applications."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/45289","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/27"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=45289"}],"version-history":[{"count":14,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/45289\/revisions"}],"predecessor-version":[{"id":100271,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/45289\/revisions\/100271"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/6571"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=45289"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=45289"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=45289"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=45289"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=45289"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=45289"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=45289"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=45289"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=45289"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}