{"id":48500,"date":"2012-05-24T14:30:00","date_gmt":"2012-05-24T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/capillary-gc-column-killers-part-3\/"},"modified":"2026-01-28T15:50:35","modified_gmt":"2026-01-28T15:50:35","slug":"capillary-gc-column-killers-part-3","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/blogs\/gnbl4608\/capillary-gc-column-killers-part-3","title":{"rendered":"Capillary GC Column Killers \u2013 Part 3"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><em><strong>Elemental Sulfur<\/strong><\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Part 3 of my installment of Capillary GC Column Killers includes a compound known to just about everyone, sulfur. Either analysts have been aware for years that this compound has been in their samples\/extracts, or they are surprised when they eventually find out that this compound has been causing their poor chromatography.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Many sample extracts, especially those from petroleum products, can contain elemental sulfur. This is not very surprising since the main source of sulfur today is derived from natural gas and petroleum products (\u00a0<a href=\"http:\/\/en.wikipedia.org\/wiki\/Sulfur\" target=\"_blank\" rel=\"noreferrer noopener\">Sulfur<\/a>\u00a0).\u00a0 Other common environmental samples which may contain high levels of sulfur are from marine sediments and industrial wastes.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"250\" height=\"188\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-capillary-gc-column-killers-part-3-01.jpg\" alt=\"\" class=\"wp-image-13162\" title=\"-\"><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Photo from Wikipedia<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">While elemental sulfur will not damage a column\u2019s phase in the strictest sense, it can, however, contaminate the phase, and is very difficult to remove. Once it has contaminated the column\u2019s phase, because sulfur is very reactive, it can cause adsorption and\/or breakdown of active compounds in succeeding samples. This is especially true with pesticides.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The EPA has known for years that samples containing elemental sulfur can cause problems with sample analysis. Three of the common methods where they mention it are 8081A, 8082A, and 8141A. For samples suspected of containing elemental sulfur, they recommend that the sulfur be removed by using activated copper or tetrabutylammonium sulfite. Details covering sulfur removal from samples are presented in <a href=\"https:\/\/www.epa.gov\/sites\/default\/files\/2015-12\/documents\/3660b.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">US EPA Method 3660B<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Please note\u00a0<\/strong>that performing sulfur cleanup on a sample may remove one or more compounds of interest. It is always wise to perform some preliminary testing before using this method on all of your samples.\u00a0 In addition to this method, my co-worker Nancy pointed out to me that\u00a0<a href=\"https:\/\/www.epa.gov\/sites\/default\/files\/2015-12\/documents\/3640a.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">EPA Method 3640A<\/a>\u00a0(GPC Cleanup)\u00a0can also be used to remove sulfur from samples, and in many cases doesn&#8217;t have unwanted chemical reactions.\u00a0 However, if the compound(s) of interest elute from the GPC column\u00a0at the same time as the sulfur, other cleanup procedures need to be considered.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Below is an example chromatogram showing a sulfur peak (graciously provided by Jack Cochran). The&nbsp;red&nbsp;chromatogram shows the sample before clean-up, and the&nbsp;blue&nbsp;after clean-up. He informed me that the compounds were organochlorine pesticides and the detector was an ECD. As you can see, not only may this huge sulfur peak make quantitation difficult for compounds of interest, but as mentioned earlier, it may leave your column very reactive.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"916\" height=\"560\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-capillary-gc-column-killers-part-3-02.bmp\" alt=\"\" class=\"wp-image-13168\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-capillary-gc-column-killers-part-3-02.bmp 916w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-capillary-gc-column-killers-part-3-02-300x183.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-capillary-gc-column-killers-part-3-02-768x470.jpg 768w\" sizes=\"auto, (max-width: 916px) 100vw, 916px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Of course there are situations where the purpose of the analysis is to look for and quantitate elemental sulfur. Several ASTM methods were written to determine the amount of elemental sulfur in petroleum products. More recently, methods were developed to look for elemental sulfur, and other sulfur-containing compounds, in drywall.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">So, in summary, if you are having chromatography issues such as tailing peaks, loss or reduction of active compounds, and unexplained contamination \u201chumps\u201d in your chromatogram after analyzing samples from petroleum products, marine sediment or industrial waste, you may be experiencing the negative effects of having elemental sulfur in your samples\/extracts. To keep your chromatography looking sharp, and possibly help your column last longer, spending some time removing this compound from your sample\/extract prior to its analysis may be well worth the extra time and effort.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Elemental Sulfur Part 3 of my installment of Capillary GC Column Killers includes a compound known to just about everyone, sulfur. Either analysts have been aware for years that this compound has been in their samples\/extracts, or they are surprised&#8230;<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[9],"tags":[],"industries-application":[2157,2161],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2294],"ppma_author":[582],"class_list":["post-48500","post","type-post","status-publish","format-standard","hentry","category-blogs","industries-application-energy","industries-application-environmental","resource-technique-gas-chromatography-gc"],"acf":[],"taxonomy_info":{"category":[{"value":9,"label":"Blogs"}],"industries-application":[{"value":2157,"label":"Energy"},{"value":2161,"label":"Environmental"}],"resource-technique":[{"value":2294,"label":"Gas Chromatography (GC)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Patrick Gallagher","author_link":"https:\/\/discover.restek.com\/fr\/author\/patrick-gallagherrestek-com\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":9,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":582,"user_id":0,"is_guest":1,"slug":"alan-sensue","display_name":"Alan Sensue","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Alan","last_name":"Sensue","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/48500","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=48500"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/48500\/revisions"}],"predecessor-version":[{"id":85251,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/48500\/revisions\/85251"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=48500"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=48500"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=48500"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=48500"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=48500"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=48500"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=48500"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=48500"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=48500"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}