{"id":51592,"date":"2018-03-29T14:30:00","date_gmt":"2018-03-29T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/a-better-way-to-configure-your-ez-no-vent-gc-ms-connector\/"},"modified":"2026-06-17T19:49:21","modified_gmt":"2026-06-17T19:49:21","slug":"a-better-way-to-configure-your-ez-no-vent-gc-ms-connector","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/blogs\/gnbl4563\/a-better-way-to-configure-your-ez-no-vent-gc-ms-connector","title":{"rendered":"A better way to configure your EZ No-Vent GC-MS Connector"},"content":{"rendered":"\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-better-way-to-configure-your-ez-no-vent-gc-ms-connector-01.png\" alt=\"decorative\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">If you are using the EZ No-Vent for Agilent mass spectrometers (cat.# 21323), you are probably tricking your instrument into working properly by inflating the length of your column in your acquisition software. If you have MassHunter, or a recent version of MSD ChemStation&nbsp; (G1701EA), you don&#8217;t have to do this. Instead of configuring your 30 m x 0.25 mm ID column as a 112 m column, you should configure a composite column (see Figure 1). Even if you aren&#8217;t using the EZ No-Vent with your mass spectrometer, you should be configuring your column as a composite column because the 17 cm transfer line is heated by the transfer line heater, not the oven.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-better-way-to-configure-your-ez-no-vent-gc-ms-connector-02.png\" alt=\"decorative\" width=\"551\" height=\"663\" title=\"-\"><br>Figure 1 &#8211; 30 m column configured as a composite column in MassHunter (without the EZ No-Vent)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Figure 2 shows a composite column configured with the 17 cm x 0.10 mm ID vacuum restrictor, which is the part of the EZ No-Vent that allows you to disconnect your analytical column without turning off your MSD. You&#8217;ll notice the average linear velocity is significantly reduced when the EZ No-Vent is used (39 cm\/sec drops to 26.8 cm\/sec) even though the volumetric flow stays the same. This has some negative chromatographic effects.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-better-way-to-configure-your-ez-no-vent-gc-ms-connector-03.png\" alt=\"decorative\" width=\"549\" height=\"656\" title=\"-\"><br>Figure 2 &#8211; 30 m column configured as a composite column in MassHunter (with the EZ No-Vent)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Figure 3 is an example chromatogram collected on a 30 m x 0.25 mm x 0.25 \u00b5m column without using the EZ No-Vent. Figure 4 shows the chromatographic effect of installing the EZ No-Vent while keeping all acquisition parameters the same (aside from configuring the restrictor in the composite column).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-better-way-to-configure-your-ez-no-vent-gc-ms-connector-04.png\" alt=\"decorative\" width=\"1280\" height=\"720\" title=\"-\"><br>Figure 3 &#8211; Example Chromatogram collected without the EZ No-Vent<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-better-way-to-configure-your-ez-no-vent-gc-ms-connector-05.png\" alt=\"decorative\" width=\"1280\" height=\"720\" title=\"-\"><br>Figure 4 &#8211; Same acquisition parameters as Figure 3, but collected with the EZ No-Vent installed<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The good resolution of the first eluting compound (1,4-Dioxane) and the dichloromethane solvent peak has collapsed, in Figure 4, and Aniline and bis(2-Chloroethyl)ether are now coeluting. The resolution for the two PAH pairs has also degraded. Lowering starting oven temperature 20\u00b0C improves the separation of 1,4-dioxane and solvent peak, though 1,4-dioxane is still on the solvent peak&#8217;s tail (see Figure 5). The PAH resolutions have also improved, almost to the level of performance when the EZ No-Vent isn&#8217;t installed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-better-way-to-configure-your-ez-no-vent-gc-ms-connector-06.png\" alt=\"decorative\" width=\"1280\" height=\"720\" title=\"-\"><br>Figure 5 &#8211; Chromatography is improved by reducing the starting oven temperature.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Produits mentionn\u00e9s<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21323\">                                R\u00e9f. 21323                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Kit de connexion EZ No-Vent, pour GC Agilent avec GC-MS 5971\/5972, 5973, 5975 ou 5977<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21323\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>If you are using the EZ No-Vent for Agilent mass spectrometers (cat.# 21323), you are probably tricking your instrument into working properly by inflating the length of your column in your acquisition software. If you have MassHunter, or a recent&#8230;<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[9],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2385,2372],"resource-technique":[2294,2301],"ppma_author":[584],"class_list":["post-51592","post","type-post","status-publish","format-standard","hentry","category-blogs","product-library-ferrules-fittings-connectors","product-library-gas-chromatography-products","resource-technique-gas-chromatography-gc","resource-technique-mass-spectrometry-ms"],"acf":[],"taxonomy_info":{"category":[{"value":9,"label":"Blogs"}],"product-library":[{"value":2385,"label":"Ferrules, Fittings, Connectors"},{"value":2372,"label":"Gas Chromatography Products"}],"resource-technique":[{"value":2294,"label":"Gas Chromatography (GC)"},{"value":2301,"label":"Mass Spectrometry (MS)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Patrick Gallagher","author_link":"https:\/\/discover.restek.com\/fr\/author\/patrick-gallagherrestek-com\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":9,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":584,"user_id":0,"is_guest":1,"slug":"chris-rattray","display_name":"Chris Rattray","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Chris","last_name":"Rattray","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/51592","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=51592"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/51592\/revisions"}],"predecessor-version":[{"id":56569,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/51592\/revisions\/56569"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=51592"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=51592"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=51592"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=51592"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=51592"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=51592"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=51592"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=51592"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=51592"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}