{"id":51628,"date":"2012-10-21T14:30:00","date_gmt":"2012-10-21T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/cannot-achieve-constant-peak-widths-troubleshooting-my-agilent-5973-ms\/"},"modified":"2026-01-28T15:47:34","modified_gmt":"2026-01-28T15:47:34","slug":"cannot-achieve-constant-peak-widths-troubleshooting-my-agilent-5973-ms","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/blogs\/gnbl4605\/cannot-achieve-constant-peak-widths-troubleshooting-my-agilent-5973-ms","title":{"rendered":"\u201cCannot achieve constant peak widths\u201c \u2013 Troubleshooting my Agilent 5973 MS"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">So my Agilent 5973 MS has been working like a gem, but I recently had to power it down. Recall from my&nbsp;previous blog, which I am sure you read, I had the power killed to my work bench. Although my system was working fine prior to the power down, I thought it would be good standard laboratory practice to tune my 5973 once I was back up running and pumped down. However upon doing so I was met with the following error:<\/p>\n\n\n\n<pre class=\"wp-block-preformatted\">Tue Oct 02 10:56:27 2012<br>App: msinsctl.exe, Method: VMS.M, RunType: Sampl, Vial: 1<br>DataFile: C:\\MSDCHEM\\1\\DATA9281292812007.D<br>Macro: ADJ_MID_MASS, Cmd: widths 30,3<br>Msg:<br><br><strong>Cannot achieve constant peak widths.<\/strong><\/pre>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-cannot-achieve-constant-peak-widths-troubleshooting-my-agilent-5973-ms-01.jpg\" alt=\"lake surrounded by mountain peaks\" class=\"wp-image-13144\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-cannot-achieve-constant-peak-widths-troubleshooting-my-agilent-5973-ms-01.jpg 800w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-cannot-achieve-constant-peak-widths-troubleshooting-my-agilent-5973-ms-01-300x225.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-cannot-achieve-constant-peak-widths-troubleshooting-my-agilent-5973-ms-01-768x576.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">If I read \u201cCannot achieve constant peak widths\u201d one more time, I am going to burn my 5973 to the ground. To better understand my disdain for the aforementioned error, here is a list of some things I checked out, cleaned, replaced, tinkered with, etc\u2026<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Vacuum was good and air\/ water was spot on.<\/li>\n\n\n\n<li>The source was spotless.<\/li>\n\n\n\n<li>Filaments were virtually brand new.<\/li>\n\n\n\n<li>Brand new ETP had been installed.<\/li>\n\n\n\n<li>PFTBA was topped off.<\/li>\n\n\n\n<li>Etc\u2026<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">I probably missed a few details, but you get the picture. I went up one side of this instrument and down the other. Nothing would work!!! The odd thing of it all was that the instrument would start the tune off looking great. 69, 219, 502 were there and looking purdy! However, as the tune went on and the system was \u201crefining\u201d itself, it would go from good to bad. It was as if my instrument was possessed to self-destruct every tune.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Cannot achieve constant peak widths\u2026 Cannot achieve constant peak widths\u2026 Cannot achieve constant peak widths\u2026<\/em>&nbsp;I think a fellow co-worker heard me murmuring my new mantra to myself.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I finally reached a point where I knew this was electrical\/software related. The only physical component left to the MS, which I had not tinkered with, was the quad. I knew I had a new side board recently replaced, so that narrowed it down to software. Instead of reinstalling Chemstation, I decided to just do a new configuration on the instrument.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To do so, click on the \u201cconfig\u201d icon on our desktop (if yours is missing, you may also find it at: c:\\msdchem\\MSexe\\msconfig.exe). From there, click on the drop down tab \u201cconfigure\u201d and select \u201cinstrument 1\u201d. Now all you need to do is click \u201cnext\u201d 6 times and then \u201cfinish\u201d\u2026 and&nbsp;<strong>PRESTO!!!<\/strong>&nbsp;If you had a corrupt tune file as it appears I did, this will cure what ails you! In the end, it turns out I was just chasing my tail around, as this corrupt tune file was never going to allow for a proper tune.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>So my Agilent 5973 MS has been working like a gem, but I recently had to power it down. Recall from my previous blog, which I am sure you read, I had the power killed to my work bench. Although&#8230;<\/p>\n","protected":false},"author":25,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[9],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2294,2301],"ppma_author":[445],"class_list":["post-51628","post","type-post","status-publish","format-standard","hentry","category-blogs","resource-technique-gas-chromatography-gc","resource-technique-mass-spectrometry-ms"],"acf":[],"taxonomy_info":{"category":[{"value":9,"label":"Blogs"}],"resource-technique":[{"value":2294,"label":"Gas Chromatography (GC)"},{"value":2301,"label":"Mass Spectrometry (MS)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jason S. Herrington, PhD","author_link":"https:\/\/discover.restek.com\/fr\/author\/jason-s-herrington-phd\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":9,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":445,"user_id":25,"is_guest":0,"slug":"jason-s-herrington-phd","display_name":"Jason S. Herrington, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-herrington-jason.png","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-herrington-jason.png"},"author_category":"1","first_name":"Jason","last_name":"Herrington","user_url":"https:\/\/www.linkedin.com\/in\/jason-herrington-97b0b620\/%20","job_title":"VP, Reference Standards Business","description":"Jason joined Restek in 2011 after spending over 10 years in environmental analysis, most notably as a postdoctoral research fellow with the U.S. EPA focusing on the development of techniques for organic speciation of ambient gas-phase and particulate air toxics. He has a BS in environmental sciences from Rutgers University and a PhD in exposure science from The University of Medicine and Dentistry of New Jersey. His wide-ranging work has been published in over a dozen peer-reviewed manuscripts and presented around the world. As a senior scientist with Restek, Jason is heavily involved with developing new air products and applications."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/51628","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/25"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=51628"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/51628\/revisions"}],"predecessor-version":[{"id":85193,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/51628\/revisions\/85193"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=51628"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=51628"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=51628"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=51628"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=51628"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=51628"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=51628"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=51628"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=51628"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}