   {"id":51637,"date":"2021-08-17T14:30:00","date_gmt":"2021-08-17T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/how-do-our-gc-chiral-columns-compare\/"},"modified":"2025-10-23T23:21:07","modified_gmt":"2025-10-23T23:21:07","slug":"how-do-our-gc-chiral-columns-compare","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/blogs\/gnbl4618\/how-do-our-gc-chiral-columns-compare","title":{"rendered":"Chiral Separations 1: How do our GC chiral columns compare?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Predicting chiral separations is challenging. Using standard capillary columns, general predictions about separations can be made based on the solubility of compounds in different phases; however, chiral predictions are far more complicated.<br><br>To make this decision somewhat easier, we compiled resolution values for the enantiomers of 21 chiral compounds with different functional groups, such as terpenes, alcohols or lactones.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-regular\"><table><tbody><tr><td colspan=\"3\">&nbsp;<\/td><td colspan=\"6\"><strong>Column Resolution Factors<\/strong><\/td><\/tr><tr><td colspan=\"3\">&nbsp;<strong>Compounds<\/strong><\/td><td>Rt-\u03b2DEX&nbsp;<strong>sm<\/strong><\/td><td>Rt-\u03b2DEX&nbsp;<strong>se<\/strong><\/td><td>Rt-\u03b2DEX&nbsp;<strong>sp<\/strong><\/td><td>Rt-\u03b2DEX&nbsp;<strong>sa<\/strong><\/td><td>Rt-\u03b2DEX&nbsp;<strong>cst<\/strong><\/td><td>Rt-\u03b2DEX&nbsp;<strong>m<\/strong><\/td><\/tr><tr><td><em>Terpenes<\/em><\/td><td>1<\/td><td>\u03b1-pinene<\/td><td>3.14<\/td><td>0.82<\/td><td><em>ns<\/em><\/td><td><em>ns<\/em><\/td><td>0.82<\/td><td>3.19<\/td><\/tr><tr><td>&nbsp;<\/td><td>2<\/td><td>limonene<\/td><td>5.60<\/td><td>8.05<\/td><td>1.22<\/td><td><em>ns<\/em><\/td><td>2.04<\/td><td>1.41<\/td><\/tr><tr><td><em>Alcohols<\/em><\/td><td>3<\/td><td>1-octen-3-ol<\/td><td>1.08<\/td><td><em>ns<\/em><\/td><td><em>ns<\/em><\/td><td>2.00<\/td><td><em>ns<\/em><\/td><td><em>ns<\/em><\/td><\/tr><tr><td>&nbsp;<\/td><td>4<\/td><td>linalool<\/td><td>3.10<\/td><td>5.96<\/td><td>1.79<\/td><td>1.60<\/td><td>2.25<\/td><td>1.01<\/td><\/tr><tr><td>&nbsp;<\/td><td>5<\/td><td>\u03b1-terpineol<\/td><td>4.72<\/td><td>5.20<\/td><td>1.29<\/td><td>2.82<\/td><td>2.69<\/td><td>1.54<\/td><\/tr><tr><td>&nbsp;<\/td><td>6<\/td><td>terpinen-4-ol<\/td><td>1.90<\/td><td>1.92<\/td><td><em>ns<\/em><\/td><td>2.47<\/td><td><em>ns<\/em><\/td><td>1.41<\/td><\/tr><tr><td>&nbsp;<\/td><td>7<\/td><td>isoborneol<\/td><td>3.76<\/td><td>3.35<\/td><td><em>ns<\/em><\/td><td>0.79<\/td><td>1.87t<\/td><td>2.15<\/td><\/tr><tr><td>&nbsp;<\/td><td>8<\/td><td>\u03b2-citronellol<\/td><td>0.80<\/td><td>0.89<\/td><td><em>ns<\/em><\/td><td>0.98<\/td><td><em>ns<\/em><\/td><td><em>ns<\/em><\/td><\/tr><tr><td>&nbsp;<\/td><td>9<\/td><td>menthol<\/td><td>1.24<\/td><td>1.24<\/td><td>1.07<\/td><td>0.93<\/td><td>0.89<\/td><td>1.58<\/td><\/tr><tr><td>&nbsp;<\/td><td>10<\/td><td>2,3-butanediol<\/td><td>6.44<\/td><td>7.10<\/td><td>1.46<\/td><td>2.61<\/td><td>1.27<\/td><td>2.43<\/td><\/tr><tr><td>&nbsp;<\/td><td>11<\/td><td>1-phenylethanol<\/td><td>7.52<\/td><td>6.52<\/td><td><em>ns<\/em><\/td><td>6.43<\/td><td>4.87<\/td><td>5.88<\/td><\/tr><tr><td><em>Ketones<\/em><\/td><td>12<\/td><td>camphor<\/td><td>1.70<\/td><td>2.13<\/td><td>0.50<\/td><td>4.20<\/td><td>2.22t<\/td><td><em>ns<\/em><\/td><\/tr><tr><td>&nbsp;<\/td><td>13<\/td><td>\u03b1-ionone<\/td><td>5.67<\/td><td>3.31<\/td><td>0.80<\/td><td>4.69<\/td><td>1.37<\/td><td>2.81<\/td><\/tr><tr><td><\/td><td>14<\/td><td>menthone<\/td><td>0.59<\/td><td>5.76<\/td><td><em>ns<\/em><\/td><td>1.16<\/td><td>2.60<\/td><td>4.11<\/td><\/tr><tr><td><em>Lactones<\/em><\/td><td>15<\/td><td>\u03b3-nonalactone<\/td><td>4.19<\/td><td>5.07<\/td><td>2.11<\/td><td>4.00<\/td><td>3.82<\/td><td>1.03<\/td><\/tr><tr><td><\/td><td>16<\/td><td>\u03b3-undecalactone<\/td><td>2.39<\/td><td>3.24<\/td><td>1.20<\/td><td>3.65<\/td><td>3.18<\/td><td><em>ns<\/em><\/td><\/tr><tr><td>&nbsp;<\/td><td>17<\/td><td>\u03b4-dodecalactone<\/td><td>0.80<\/td><td><em>ns<\/em><\/td><td><em>ns<\/em><\/td><td>1.91<\/td><td>1.69<\/td><td><em>ns<\/em><\/td><\/tr><tr><td>&nbsp;<\/td><td>18<\/td><td>ethyl-2-methylbutyrate<\/td><td>3.94<\/td><td>4.66<\/td><td><em>ns<\/em><\/td><td><em>ns<\/em><\/td><td><em>ns<\/em><\/td><td>0.92<\/td><\/tr><tr><td><em>Esters<\/em><\/td><td>19<\/td><td>linalyl acetate<\/td><td><em>ns<\/em><\/td><td>2.36<\/td><td><em>ns<\/em><\/td><td><em>ns<\/em><\/td><td><em>ns<\/em><\/td><td><em>ns<\/em><\/td><\/tr><tr><td>&nbsp;<\/td><td>20<\/td><td>styrene oxide<\/td><td>4.53<\/td><td>10.77<\/td><td>2.86<\/td><td>2.26<\/td><td>1.16t<\/td><td>3.03<\/td><\/tr><tr><td><em>Epoxides<\/em><\/td><td>21<\/td><td><em>trans<\/em>-linalool oxide<\/td><td>9.71<\/td><td>2.96<\/td><td><em>ns<\/em><\/td><td>1.20<\/td><td>3.02t<\/td><td>7.44<\/td><\/tr><tr><td>&nbsp;<\/td><td>21<\/td><td><em>cis<\/em>-linalool oxide<\/td><td>6.06<\/td><td>4.28<\/td><td><em>ns<\/em><\/td><td>0.91<\/td><td>2.19t<\/td><td>4.38<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Predicting chiral separations is challenging. To make this decision somewhat easier, we compiled resolution values from 21 chiral compounds with different functional groups, such as terpenes, alcohols or lactones.<\/p>\n","protected":false},"author":50,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[2806],"tags":[],"industries-application":[2173,2191],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2307],"ppma_author":[591],"class_list":["post-51637","post","type-post","status-publish","format-standard","hentry","category-blogs","industries-application-cannabis-zh","industries-application-food-beverage-zh","resource-technique-gas-chromatography-gc-zh"],"acf":[],"taxonomy_info":{"category":[{"value":2806,"label":"Blogs"}],"industries-application":[{"value":2173,"label":"\u5927\u9ebb"},{"value":2191,"label":"\u98df\u54c1\u548c\u996e\u6599"}],"resource-technique":[{"value":2307,"label":"\u6c14\u76f8\u8272\u8c31\uff08GC\uff09"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jana Hepner, PhD","author_link":"https:\/\/discover.restek.com\/fr\/author\/jana-hepner-phd\/"},"comment_info":0,"category_info":[{"term_id":2806,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":2806,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":2806,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":591,"user_id":50,"is_guest":0,"slug":"jana-hepner-phd","display_name":"Jana Hepner, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hepner-jana.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hepner-jana.jpg"},"author_category":"1","first_name":"Jana","last_name":"Hepner","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/51637","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/50"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=51637"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/51637\/revisions"}],"predecessor-version":[{"id":56838,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/51637\/revisions\/56838"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=51637"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=51637"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=51637"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=51637"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=51637"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=51637"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=51637"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=51637"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=51637"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}