{"id":51647,"date":"2011-04-02T14:30:00","date_gmt":"2011-04-02T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/chromatography-challenge-does-a-gc-capillary-column-produce-different-retention-times-when-installed-in-the-opposite-direction-share-your-opinion\/"},"modified":"2026-08-11T15:34:36","modified_gmt":"2026-08-11T15:34:36","slug":"chromatography-challenge-does-a-gc-capillary-column-produce-different-retention-times-when-installed-in-the-opposite-direction-share-your-opinion","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/blogs\/gnbl4629\/chromatography-challenge-does-a-gc-capillary-column-produce-different-retention-times-when-installed-in-the-opposite-direction-share-your-opinion","title":{"rendered":"Chromatography challenge: Does a GC-capillary column produce different retention times when installed in the opposite direction? Share your opinion!"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">A little challenge for our regular blog-visitors..<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Capillary chromatography has become quite an adult science, but we still discover new and better ways to do better chromatography and generate more accurate data.&nbsp; Besides that GC columns get very inert, have low bleed and are usable up to high temperatures, also the design of columns has changed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">With \u201cdesign\u201d I mean how columns are physically made. By using \u201csegment\u201d coating we can deposit stationary phase in different positions of the capillary. Instead of having a long, uniform coated capillary, we can make now an Integrated Guards or Integrated Retention-gaps, all in one piece of capillary.&nbsp; So, &nbsp;new generation columns often have a \u201cfront\u201d and a \u201cback\u201d side..&nbsp; Now an interesting discussion starts:&nbsp; \u201cwhat can I expect to happen if I install my column in the \u201cwrong\u201d way?\u201d..<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The challenge is here:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">We have a 40m x 0.25mm Rxi-5Sil MS capillary, where we have an integrated guard column of 10 meter. The coated analytical column is effectively 30 meter long. The 10m guard section is only \u201cdeactivated\u201d and the retention will be minimal.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"900\" height=\"657\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-chromatography-challenge-does-a-gc-capillary-column-produce-different-retention-times-when-installed-in-the-opposite-direction-share-your-opinion-01.gif\" alt=\"\" class=\"wp-image-13450\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The same column, used in 2 different directions: A: with guard section in FRONT; B: with Guard section at the BACK<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">We position the column in our GC first in position A, see figure. Here the guard is direct connected at the inlet. The column is heated to test temperature and we check the linear gas velocity by injecting methane; Then we run a test mixture and we measure the retention times for all components.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Now we change column position into position B. The Guard section is now directly connected to the detector. We use exactly the same column and do exactly the same exercise as above.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em><strong>The Question is: What will happen with the retention times for all components?<\/strong><\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Note:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>We use the same column, so the length, ID and amount of stationary phase is exactly the same;<\/li>\n\n\n\n<li>We test at the same temperature and use the same inlet pressure;<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Our Options:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>The components in situation \u201cB\u201d elute at exactly the same retention times a situation \u201cA\u201d;<\/strong><\/li>\n\n\n\n<li><strong>The components in situation \u201dB\u201d elute FASTER, so it seems the column has less retention;<\/strong><\/li>\n\n\n\n<li><strong>The components in situation \u201cB\u201d elute LATER. So it seems the column has more retention;<\/strong><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">Please send your answers.\u00a0 Just state which option you choose.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">We list the top 25 correct answers when we get back to this discussion in about 4 weeks;<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>A little challenge for our regular blog-visitors.. Capillary chromatography has become quite an adult science, but we still discover new and better ways to do better chromatography and generate more accurate data. Besides that GC columns get very inert, have&#8230;<\/p>\n","protected":false},"author":19,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[9],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[439],"class_list":["post-51647","post","type-post","status-publish","format-standard","hentry","category-blogs"],"acf":[],"taxonomy_info":{"category":[{"value":9,"label":"Blogs"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jaap de Zeeuw","author_link":"https:\/\/discover.restek.com\/fr\/author\/jaap-de-zeeuw\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":9,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":439,"user_id":19,"is_guest":0,"slug":"jaap-de-zeeuw","display_name":"Jaap de Zeeuw","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-de-zeeuw-jaap.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-de-zeeuw-jaap.jpg"},"author_category":"1","first_name":"Jaap","last_name":"de Zeeuw","user_url":"https:\/\/www.linkedin.com\/in\/jaap-de-zeeuw-ba102a7\/","job_title":"GC Consultant","description":"Jaap is a world-renowned chromatographer with over 40 years of experience, including 15 years with Restek and 27 years with Varian\/Chrompack prior to joining Restek. Throughout his career, Jaap has focused the chromatographic challenges of industrial analysis. For his 1979 graduation from The Institute for Higher Education, where he specialized in chemistry, Jaap authored a paper titled \"The Challenge of Coating Flexible Fused Silica Capillary Columns\" and has since distinguished himself as an authority on the subject. Jaap has been directly involved with the creation of numerous chemically bonded columns, including the first bonded PEG column and the stabilized PLOT columns widely used in the petrochemical arena. He has also helped develop new techniques, such as fast GC-MS using vacuum GC technology (low-pressure GC or LPGC). Over his innovative career, he has filed several patents for his work. Based out of the Netherlands, Jaap is extensively published and regularly travels internationally to share his knowledge. After retiring from Restek, Jaap founded CreaVisions, where he works as a GC Consultant and teaches master classes on key GC topics as well as on creativity in science."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/51647","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/19"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=51647"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/51647\/revisions"}],"predecessor-version":[{"id":73328,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/51647\/revisions\/73328"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=51647"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=51647"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=51647"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=51647"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=51647"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=51647"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=51647"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=51647"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=51647"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}