{"id":51729,"date":"2013-08-20T14:30:00","date_gmt":"2013-08-20T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/is-there-a-limit-to-the-volume-you-can-inject-into-an-agilent-splitsplitless-inlet\/"},"modified":"2025-10-29T19:11:09","modified_gmt":"2025-10-29T19:11:09","slug":"is-there-a-limit-to-the-volume-you-can-inject-into-an-agilent-splitsplitless-inlet","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/blogs\/gnbl4722\/is-there-a-limit-to-the-volume-you-can-inject-into-an-agilent-splitsplitless-inlet","title":{"rendered":"Is there a limit to the volume you can inject into an agilent split\/splitless inlet?"},"content":{"rendered":"<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"960\" height=\"720\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-is-there-a-limit-to-the-volume-you-can-inject-into-an-agilent-splitsplitless-inlet-01.png\" alt=\"\" class=\"wp-image-13828\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-is-there-a-limit-to-the-volume-you-can-inject-into-an-agilent-splitsplitless-inlet-01.png 960w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-is-there-a-limit-to-the-volume-you-can-inject-into-an-agilent-splitsplitless-inlet-01-300x225.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-is-there-a-limit-to-the-volume-you-can-inject-into-an-agilent-splitsplitless-inlet-01-768x576.png 768w\" sizes=\"auto, (max-width: 960px) 100vw, 960px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Theoretically, the answer is no; the limiting factor of a concurrent solvent recondensation &#8211; large volume splitless injection (CSR_LVSI)&nbsp;is the surface area available to support a stable film of recondensed solvent. If you read&nbsp;my previous post, which utilized a 50 \u00b5L injection to meet lower detection limits for 1,4-dioxane and various nitrosamines, you may have noticed that I used a 10 m 0.53 mm ID pre-column. This was to insure there was enough surface for the 50 \u00b5L injection to recondense and form a stable film, without flooding the phase-coated analytical column.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Theoretical limits aside, if you don&#8217;t have a 7693 autosampler with the enhanced sample handling syringe carriage, you are effectively limited to 50 \u00b5L injections because the standard syringe carriage can&#8217;t hold larger than a 100 \u00b5L autosampler syringe. While you can perform multiple injections for a single analysis, peak shapes will surely suffer without the sub-ambient cooling and analyte trapping associated with a PTV (and we are working with compounds too volatile for this to be effective anyhow).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Earlier this week, I finally installed my enhanced sample handling syringe carriage and 500 \u00b5L autosampler syringe, giving&nbsp; me an effective injection volume limit of 250 \u00b5L. The chromatogram above is the result. Notice that I used a 30m 0.53 mm ID pre-column to provide plenty of room for solvent recondensation. I plan to empirically discover the optimal pre-column length for this large injection volume through a series of column trimming experiments, so stay tuned.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">I also want to point out the strength of the signal for a 0.1 \u00b5g\/mL standard. If this was a extract prepared via EPA 521 or 522, it would be equivalent to a 2 ng\/L sample (2 ppt). This would allow for trace analysis of drinking water samples using a single quadrupole instrument in scan mode.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As with most things in life, there are tradeoffs. The solvent delay for a 250 \u00b5L injection is a little over 30 minutes (if you need to detect THF and 1,4-dioxane for EPA Method 522) or 38 minutes in the chromatogram above, which deals solely with the nitrosamines. Using a simple 11.12 degree per minute ramp after an extended 50 degree hold to evaporate and elute the dichloromethane yields a total analysis time of nearly 60 minutes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If you look at the chromatogram below, you&#8217;ll see there is still a good separation between the solvent peak and tetrahydrofuran (THF), the first eluting (highly volatile) peak in the mix. Even with a 250 \u00b5L injection, THF, which has a boiling point only 26 degrees higher than dichloromethane, is not lost to &#8220;backflash&#8221; and shows good symmetric peak shape.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-is-there-a-limit-to-the-volume-you-can-inject-into-an-agilent-splitsplitless-inlet-02.png\" alt=\"250\u00b5L injection 521 scan mode 0.1\u00b5g-mL (2)\" class=\"wp-image-9688\" title=\"-\"><\/figure>\n<\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Theoretically, the answer is no; the limiting factor of a concurrent solvent recondensation &#8211; large volume splitless injection (CSR_LVSI) is the surface area available to support a stable film of recondensed solvent. If you read my previous post, which utilized&#8230;<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[9],"tags":[],"industries-application":[2271],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2340],"ppma_author":[584],"class_list":["post-51729","post","type-post","status-publish","format-standard","hentry","category-blogs","industries-application-environmental-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":9,"label":"Blogs"}],"industries-application":[{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Patrick Gallagher","author_link":"https:\/\/discover.restek.com\/fr\/author\/patrick-gallagherrestek-com\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":9,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":584,"user_id":0,"is_guest":1,"slug":"chris-rattray","display_name":"Chris Rattray","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Chris","last_name":"Rattray","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/51729","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=51729"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/51729\/revisions"}],"predecessor-version":[{"id":59263,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/51729\/revisions\/59263"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=51729"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=51729"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=51729"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=51729"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=51729"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=51729"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=51729"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=51729"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=51729"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}