{"id":51854,"date":"2014-06-05T14:30:00","date_gmt":"2014-06-05T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/what-is-the-difference-between-restek-nitrogen-generators-which-use-electricity-and-those-which-do-not\/"},"modified":"2025-10-29T11:58:35","modified_gmt":"2025-10-29T11:58:35","slug":"what-is-the-difference-between-restek-nitrogen-generators-which-use-electricity-and-those-which-do-not","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/blogs\/gnbl4862\/what-is-the-difference-between-restek-nitrogen-generators-which-use-electricity-and-those-which-do-not","title":{"rendered":"What is the difference between Restek nitrogen generators which use electricity and those which do not?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">You may have reviewed our product webpage for&nbsp;Parker Balston&nbsp;Nitrogen Gas Generators for LC-MS&nbsp;and noticed that is states:&nbsp;<strong>Models N2-04, N2-14, N2-22, and N2-35 require no electricity<\/strong>.&nbsp; So why don\u2019t these models require electricity but models N2-14A, N2-22A, and N2-35A do?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The simple answer is: those which use electricity have an oxygen sensor and audible alarm built into them, and the others don\u2019t.&nbsp; The oxygen sensor monitors the oxygen content in the nitrogen process stream.&nbsp; When the oxygen level increases above the set-point, an alarm will sound letting you know that gas output does not meet&nbsp;purity specifications.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Please note<\/strong>:&nbsp;&nbsp;Models N2-14A, N2-22A&nbsp;and N2-35A may be available from Restek as custom products.&nbsp; Please ask your Restek Sales Representative if interested in obtaining a quote for these or any gas generator.&nbsp;<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"200\" height=\"200\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-what-is-the-difference-between-restek-nitrogen-generators-which-use-electricity-and-those-which-do-not-01.jpg\" alt=\"\" class=\"wp-image-17542\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-what-is-the-difference-between-restek-nitrogen-generators-which-use-electricity-and-those-which-do-not-01.jpg 200w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-what-is-the-difference-between-restek-nitrogen-generators-which-use-electricity-and-those-which-do-not-01-150x150.jpg 150w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Some other things you may not know about the nitrogen generators we sell:.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">*\u00a0 If you are going to use nitrogen for\u00a0<strong>GC carrier gas<\/strong>, choose an Ultra-High Purity generator like 20697.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">*&nbsp; We also sell maintenance kits.<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Produits mentionn\u00e9s<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/20697\">                                R\u00e9f. 20697                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">G\u00e9n\u00e9rateur d\u2019azote Parker, mod\u00e8le UHPN2-1100 (haute puret\u00e9, qualit\u00e9 z\u00e9ro)<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/20697\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>You may have reviewed our product webpage for Parker Balston Nitrogen Gas Generators for LC-MS and noticed that is states: Models N2-04, N2-14, N2-22, and N2-35 require no electricity. So why don&rsquo;t these models require electricity but models N2-14A, N2-22A,&#8230;<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[9],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[582],"class_list":["post-51854","post","type-post","status-publish","format-standard","hentry","category-blogs"],"acf":[],"taxonomy_info":{"category":[{"value":9,"label":"Blogs"}]},"featured_image_src_large":false,"author_info":{"display_name":"Patrick Gallagher","author_link":"https:\/\/discover.restek.com\/fr\/author\/patrick-gallagherrestek-com\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":9,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":582,"user_id":0,"is_guest":1,"slug":"alan-sensue","display_name":"Alan Sensue","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Alan","last_name":"Sensue","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/51854","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=51854"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/51854\/revisions"}],"predecessor-version":[{"id":58888,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/51854\/revisions\/58888"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=51854"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=51854"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=51854"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=51854"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=51854"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=51854"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=51854"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=51854"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=51854"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}