{"id":60180,"date":"2026-02-16T18:04:21","date_gmt":"2026-02-16T18:04:21","guid":{"rendered":"https:\/\/discover.restek.com\/?p=60180"},"modified":"2025-12-13T04:20:16","modified_gmt":"2025-12-13T04:20:16","slug":"tableau-des-equivalences-de-colonnes-gc","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/articles-fr\/gnot3472-fr\/tableau-des-equivalences-de-colonnes-gc","title":{"rendered":"Tableau des \u00e9quivalences de colonnes GC"},"content":{"rendered":"<style>.kb-table-of-content-nav.kb-table-of-content-id60180_e318a4-03 .kb-table-of-content-wrap{padding-top:var(--global-kb-spacing-sm, 1.5rem);padding-right:var(--global-kb-spacing-sm, 1.5rem);padding-bottom:var(--global-kb-spacing-sm, 1.5rem);padding-left:var(--global-kb-spacing-sm, 1.5rem);}.kb-table-of-content-nav.kb-table-of-content-id60180_e318a4-03 .kb-table-of-contents-title-wrap{padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.kb-table-of-content-nav.kb-table-of-content-id60180_e318a4-03 .kb-table-of-contents-title{font-weight:regular;font-style:normal;}.kb-table-of-content-nav.kb-table-of-content-id60180_e318a4-03 .kb-table-of-content-wrap .kb-table-of-content-list{font-weight:regular;font-style:normal;margin-top:var(--global-kb-spacing-sm, 1.5rem);margin-right:0px;margin-bottom:0px;margin-left:0px;}<\/style>\n\n\n<h2 class=\"wp-block-heading\">Fused Silica GC Columns<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th><strong>Restek<\/strong><\/th><th><strong>Phase<br>Description<\/strong><\/th><th><strong>USP<br>Nomenclature<\/strong><\/th><th><strong>Similar to Agilent<\/strong><\/th><th><strong>Similar to SGE<\/strong><\/th><th><strong>Similar to Phenomenex<\/strong><\/th><th><strong>Similar to Machery-Nagel<\/strong><\/th><th><strong>Similar to Supelco<\/strong><\/th><th><strong>Similar to Quadrex<\/strong><\/th><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1688\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/c\/1688\" rel=\"noreferrer noopener\"><strong>Rtx-1<\/strong><\/a><\/td><td>dimethyl polysiloxane<\/td><td>G1, G2, G9, G38<\/td><td>HP-1, DB-1,<br>CP-Sil 5 CB<\/td><td>BP1<\/td><td>ZB-1<\/td><td>OPTIMA 1<\/td><td>Equity 1, SPB-1<\/td><td>007-1<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1683\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-1HT<\/strong><\/a><\/td><td>dimethyl polysiloxane<\/td><td><\/td><td>DB-1ht<\/td><td><\/td><td>ZB-1HT inferno<\/td><td><\/td><td><\/td><td>007-1HT<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1676\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/c\/1676\" rel=\"noreferrer noopener\"><strong>Rxi-1ms<\/strong><\/a><\/td><td>dimethyl polysiloxane<br>(low bleed)<\/td><td>G1, G2, G9, G38<\/td><td>HP-1ms,<br>HP-1ms UI,<br>DB-1ms,<br>DB-1ms UI,<br>VF-1ms<\/td><td>BP1<\/td><td>ZB-1ms<\/td><td>OPTIMA 1 MS, OPTIMA 1 MS, Accent<\/td><td>SLB-1ms<\/td><td>007-1MS<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1689\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-5<\/strong><\/a><\/td><td>diphenyl dimethyl polysiloxane<\/td><td>G27, G36<\/td><td>CP-Sil 8 CB, DB-5, HP-5<\/td><td>BP5<\/td><td>ZB-5<\/td><td>OPTIMA 5<\/td><td>Equity-5, SPB-5<\/td><td>007-5<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1691\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-5MS<\/strong><\/a><\/td><td>diphenyl dimethyl polysiloxane<\/td><td>G27, G36<\/td><td>CP-Sil 8 CB, DB-5, HP-5, HP-5ms, Ultra-2<\/td><td><\/td><td>ZB-5, ZB-5MS<\/td><td><\/td><td>Equity-5, SPB-5<\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1685\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-5HT<\/strong><\/a><\/td><td>diphenyl dimethyl polysiloxane<\/td><td>G27, G36<\/td><td>DB-5ht,<br>VF-5ht<\/td><td>HT5<\/td><td>ZB-5HTinferno<\/td><td>OPTIMA 5HT<\/td><td><\/td><td>007-5HT<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1675\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-5ms<\/strong><\/a><\/td><td>diphenyl dimethyl<br>polysiloxane<br>(low bleed)<\/td><td>G27, G36<\/td><td>HP-5ms UI<\/td><td>BP5MS<\/td><td>ZB-5plus<\/td><td>OPTIMA 5 MS<\/td><td>SPB-5<\/td><td>007-5MS<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1679\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-5Sil MS<\/strong><\/a><\/td><td>1,4-bis(dimethylsiloxy)<br>phenylene dimethyl<br>polysiloxane<\/td><td>G27, G36<\/td><td>DB-5msUI<\/td><td>BPX5<\/td><td>ZM-5MS plus<\/td><td>OPTIMA 5 MS Accent<\/td><td>SLB-5ms<\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1678\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-XLB<\/strong><\/a><\/td><td>proprietary phase<\/td><td><\/td><td>DB-XLB,<br>VF-Xms<\/td><td><\/td><td>MR1, ZB-XLB<\/td><td>OPTIMA XLB<\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1692\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-20<\/strong><\/a><\/td><td>diphenyl dimethyl<br>polysiloxane<\/td><td>G32<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>SPB-20<\/td><td>007-20<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1693\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-35<\/strong><\/a><\/td><td>diphenyl dimethyl<br>polysiloxane<\/td><td>G42<\/td><td>HP-35, DB-35<\/td><td><\/td><td>ZB-35<\/td><td><\/td><td>SPB-35<\/td><td>007-35<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1682\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-35Sil MS<\/strong><\/a><\/td><td>proprietary phase<\/td><td>G42<\/td><td>VF-35ms<\/td><td>BPX35, BPX608<\/td><td>MR2<\/td><td>OPTIMA 35 MS<\/td><td><\/td><td>007-35MS<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1695\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-50<\/strong><\/a><\/td><td>phenyl methyl<br>polysiloxane<\/td><td>G3<\/td><td>HP-50+<\/td><td><\/td><td><\/td><td><\/td><td>SPB-50<\/td><td>007-17<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1673\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-17<\/strong><\/a><\/td><td>diphenyl dimethyl<br>polysiloxane<\/td><td>G3<\/td><td>DB-17<\/td><td><\/td><td>ZB-50<\/td><td>OPTIMA 17<\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1686\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-17Sil MS<\/strong><\/a><\/td><td>proprietary phase<\/td><td>G3<\/td><td>DB-17ms<\/td><td>BPX50<\/td><td>ZB-50<\/td><td>OPTIMA 17 MS<\/td><td><\/td><td>007-17MS<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1696\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-65<\/strong><\/a><\/td><td>diphenyl dimethyl<br>polysiloxane<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>007-65HT<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1674\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-624Sil MS<\/strong><\/a><\/td><td>proprietary phase<\/td><td>G43<\/td><td>VF-624ms<\/td><td>BPX-Volatiles<\/td><td>ZB-624plus<\/td><td><\/td><td><\/td><td>007-502, 007-608, 007-624<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1677\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-1301Sil MS<\/strong><\/a><\/td><td>silarylene-based cyano<\/td><td>G43<\/td><td>VF-1301ms<\/td><td><\/td><td>ZB-624plus<\/td><td><\/td><td><\/td><td>007-502, 007-608, 007-624<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1687\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-LAO<\/strong><\/a><\/td><td>midpolarity Crossbond phase<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1680\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-SVOCms<\/strong><\/a><\/td><td>Proprietary 5% phenyl-type phase<\/td><td>G27, G36<\/td><td>DB-5ms, DB-5ms UI, DB-UI 8270D<\/td><td><\/td><td>ZB-Semivolatiles<\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1704\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-1301<\/strong><\/a><br><a href=\"https:\/\/www.restek.com\/c\/1703\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-624<\/strong><\/a><\/td><td>cyanopropylmethyl phenylmethyl<br>polysiloxane<\/td><td>G43<\/td><td>CP-Select 624 CB, DB-1301,<br>DB-624,<br>DB-624UI,<br>DB-Select 624UI<\/td><td>BP624<\/td><td>ZB-624<\/td><td>OPTIMA 1301, OPTIMA 624<\/td><td>SPB-624<\/td><td>007-1301, 007-502,<br>007-624<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1706\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-1701<\/strong><\/a><\/td><td>cyanopropylmethyl phenylmethyl<br>polysiloxane<\/td><td>G46<\/td><td>DB-1701P,<br>DB-1701,<br>VF-1701 Pesticides<\/td><td>BP10<\/td><td>ZB-1701,<br>ZB-1701P<\/td><td>OPTIMA 1701<\/td><td>Equity-1701<\/td><td>007-1701<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1698\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-200<\/strong><\/a><\/td><td>trifluoropropylmethyl polysiloxane<\/td><td>G6<\/td><td>DB-210,<br>DB-200<\/td><td><\/td><td><\/td><td>OPTIMA 210<\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1699\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-200MS<\/strong><\/a><\/td><td>trifluoropropylmethyl polysiloxane<br>(low bleed)<\/td><td>G6<\/td><td>VF-200ms<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1700\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-225<\/strong><\/a><\/td><td>cyanopropylmethyl phenylmethyl<br>polysiloxane<\/td><td>G7, G19<\/td><td>DB-225ms<\/td><td>BP225<\/td><td><\/td><td>OPTIMA 225<\/td><td>SPB-225<\/td><td>007-225<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1701\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-440<\/strong><\/a><\/td><td>proprietary phase<\/td><td><\/td><td colspan=\"6\"><strong>Restek Innovation<\/strong><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1707\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-2330<\/strong><\/a><\/td><td>biscyanopropyl cyanopropylphenyl<br>polysiloxane<\/td><td>G5, G8<\/td><td>VF-23ms<\/td><td>BPX70<\/td><td><\/td><td><\/td><td>SP-2330,<br>SP-2331,<br>SP-2380<\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1722\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-2560<\/strong><\/a><\/td><td>biscyanopropyl polysiloxane<\/td><td>G5<\/td><td><\/td><td><\/td><td>ZB-FAME<\/td><td><\/td><td>SP-2560<\/td><td>SLP-2560<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1690\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-5 Amine<\/strong><\/a><\/td><td>5% diphenyl 95% dimethyl polysiloxane<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>OPTIMA 5 Amine<\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1681\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rxi-PAH<\/strong><\/a><\/td><td>proprietary phase<\/td><td>G51<\/td><td colspan=\"6\"><strong>Restek Innovation<\/strong><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1721\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rtx-Wax<\/strong><\/a><\/td><td>polyethylene glycol<\/td><td>G16, G47<\/td><td>CP-Wax 52 CB, DB-Wax, DB-WAX UI<\/td><td>BP20<\/td><td>ZB-Wax<\/td><td>OPTIMA WAX<\/td><td><\/td><td>BRT-CW<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/p\/12497\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>FAMEWAX<\/strong><\/a><\/td><td>polyethylene glycol<\/td><td>G16<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>Omegawax<\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1725\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Stabilwax<\/strong><\/a><\/td><td>polyethylene glycol<\/td><td>G16, G47<\/td><td>HP-INNOWax<\/td><td><\/td><td>ZB-WAXplus<\/td><td><\/td><td>SUPELCOWAX 10<\/td><td>007-CW<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1726\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Stabilwax-DA<\/strong><\/a><\/td><td>polyethylene glycol modified for acids<\/td><td>G25, G35<\/td><td>CP-FFAP CB, CP-Wax 58 FFAP CB, DB-FFAP, HP-FFAP, VF-DA<\/td><td>BP21<\/td><td>ZB-FFAP<\/td><td>OPTIMA FFAP, OPTIMA FFAP Plus, PERMABOND FFAP<\/td><td>Nukol<\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1727\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Stabilwax-DB<\/strong><\/a><\/td><td>polyethylene glycol modified for bases<\/td><td><\/td><td>CAM, CP-Wax 51<\/td><td><\/td><td><\/td><td>FS-CW 20 M-AM<\/td><td>Carbowax Amine<\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1728\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Stabilwax-MS<\/strong><\/a><\/td><td>polyethylene glycol<\/td><td>G16, G47<\/td><td>VF-WAX MS<\/td><td><\/td><td><\/td><td><\/td><td>SUPELCOWAX 10<\/td><td>007-CW<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">MXT GC Columns<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th><strong>Restek<\/strong><\/th><th><strong>Phase<br>Description<\/strong><\/th><th><strong>USP<br>Nomenclature<\/strong><\/th><th><strong>Similar to Agilent<\/strong><\/th><th><strong>Similar to SGE<\/strong><\/th><th><strong>Similar to Phenomenex<\/strong><\/th><th><strong>Similar to Machery-Nagel<\/strong><\/th><th><strong>Similar to Supelco<\/strong><\/th><th><strong>Similar to Quadrex<\/strong><\/th><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1730\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-1<\/strong><\/a><\/td><td>dimethyl polysiloxane<\/td><td>G1, G2, G9, G38<\/td><td>DB-1, DB-PS1<\/td><td>BP1<\/td><td><\/td><td><\/td><td><\/td><td>UAC-1, UAC-1MS<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1731\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-1HT SimDist<\/strong><\/a><\/td><td>dimethyl polysiloxane<\/td><td>G1, G2, G9, G38<\/td><td>CP-SimDist<\/td><td><\/td><td>ZB-1XT SimDist<\/td><td><\/td><td><\/td><td>UAC-SIM<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1732\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-5<\/strong><\/a><\/td><td>diphenyl dimethyl polysiloxane<\/td><td>G27, G36<\/td><td>DB-PS5, VF-5ht UltiMetal<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>UAC-5, UAC-5MS<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1734\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-50<\/strong><\/a><\/td><td>phenyl methyl<br>polysiloxane<\/td><td>G3<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>UAC-17<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1735\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-65TG<\/strong><\/a><\/td><td>diphenyl dimethyl polysiloxane<\/td><td><\/td><td>CP-TAP-CB Ultimetal<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>UAC-65HT<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1739\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-1301<\/strong><\/a><\/td><td>cyanopropylmethyl phenylmethyl<br>polysiloxane<\/td><td>G43<\/td><td>DB-PS1301,<br>DB-PS624<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>UAC-624<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1740\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-1701<\/strong><\/a><\/td><td>cyanopropylmethyl phenylmethyl<br>polysiloxane<\/td><td>G46<\/td><td>DB-PS1701<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td>UAC-1701<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1736\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-200<\/strong><\/a><\/td><td>trifluoropropylmethyl polysiloxane<\/td><td>G6<\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1748\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-WAX<\/strong><\/a><\/td><td>polyethylene glycol<\/td><td>G16<\/td><td>CP-Wax 52 CB, DB-PSWAX<\/td><td><\/td><td>ZB-WAXplus<\/td><td><\/td><td><\/td><td>UAC-CW<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">PLOT GC Columns<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th><strong>Restek<br>(Phase Description)<\/strong><\/th><th><strong>USP<br>Nomenclature<\/strong><\/th><th><strong>Porous<br>Layer<\/strong><\/th><th><strong>Application<\/strong><\/th><th><strong>Similar to Agilent<br>(J&amp;W, Varian, Chrompack)<\/strong><\/th><th><strong>Similar to Supelco<\/strong><\/th><th><strong>Similar to Quadrex<\/strong><\/th><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1751\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-Alumina BOND\/Na<sub>2<\/sub>SO<sub>4<\/sub><\/strong><\/a><\/td><td><\/td><td>Aluminum oxide<\/td><td>C1-C5 hydrocarbons purity analysis of ethylene, propylene, butenes, and halocarbons<\/td><td>CP-Al<sub>2<\/sub>0<sub>3<\/sub>\/Na<sub>2<\/sub>SO<sub>4<\/sub>,GS-Alumina<\/td><td>Alumina-sulfate<\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1743\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-Alumina BOND\/Na<sub>2<\/sub>SO<sub>4<\/sub><\/strong><\/a><\/td><td><\/td><td>Aluminum oxide<\/td><td>C1-C5 hydrocarbons purity analysis of ethylene, propylene, butenes, and halocarbons<\/td><td>CP-Al<sub>2<\/sub>0<sub>3<\/sub>\/Na<sub>2<\/sub>SO<sub>4<\/sub><\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1749\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-Alumina BOND\/KCl<\/strong><\/a><\/td><td><\/td><td>Aluminum oxide<\/td><td>C1-C8 hydrocarbons; C1-C5 isomers purity analysis of ethylene, propylene, butene, and butadiene<\/td><td>GS-Alumina KCl,<br>HP PLOT Al<sub>2<\/sub>0<sub>3<\/sub>,<br>CP-Al<sub>2<\/sub>0<sub>3<\/sub>\/KCl<\/td><td>Alumina-chloride<\/td><td>&nbsp;<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/p\/19763\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-Alumina BOND\/CFC<\/strong><\/a><\/td><td><\/td><td>Aluminum oxide<\/td><td>Multi-halogenated alkanes, C1-C5 range chlorofluorocarbons (CFC)<\/td><td colspan=\"3\"><strong>Unique Product<\/strong><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1750\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-Alumina BOND\/MAPD<\/strong><\/a><\/td><td><\/td><td>Aluminum oxide<\/td><td>Trace analysis of methyl acetylene, propadiene, and acetylene<\/td><td>Select Al<sub>2<\/sub>0<sub>3<\/sub>&nbsp;MAPD<\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1742\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-Alumina BOND\/MAPD<\/strong><\/a><\/td><td><\/td><td>Aluminum oxide<\/td><td>Trace analysis of methyl acetylene, propadiene, and acetylene<\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1752\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-Msieve 5A<\/strong><\/a><\/td><td><\/td><td>Molecular sieve 5A<\/td><td>Permanent gas analysis (He, Ne, Ar, O<sub>2<\/sub>, N<sub>2<\/sub>, Xe, Rn, CH<sub>4<\/sub>, and CO)<\/td><td>CP-Molsieve 5A, HP-PLOT Molesieve<\/td><td>Molsieve 5A<\/td><td>PLT-5A<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1745\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-Msieve 5A<\/strong><\/a><\/td><td><\/td><td>Molecular sieve 5A<\/td><td>Permanent gas analysis (He, Ne, Ar, O<sub>2<\/sub>, N<sub>2<\/sub>, Xe, Rn, CH<sub>4<\/sub>, and CO)<\/td><td><\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1753\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-Q-BOND<\/strong><\/a><br>(nonpolar porous polymer)<\/td><td><\/td><td>100% Divinylbenzene<\/td><td>High retention for solvents, alcohols, polar volatiles, CO<sub>2<\/sub>, and ppm-level water in solvents<\/td><td>HP-PLOT Q, PoraBOND Q, PoraPLOT Q<\/td><td>Supel-Q-PLOT<\/td><td>PLT-Q<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1746\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>MXT-Q-BOND<\/strong><\/a> (nonpolar porous polymer)<\/td><td>G45<\/td><td>100% Divinylbenzene<\/td><td>High retention for solvents, alcohols, polar volatiles, CO<sub>2<\/sub>, and ppm-level water in solvents<\/td><td>PoraPLOT Q,<br>Ultimetal<\/td><td><\/td><td>PLT-Q&nbsp;<\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1754\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-QS-BOND<\/strong><\/a><br>[intermediate polarity porous polymer (polarity between Q-BOND and S-BOND)]<\/td><td><\/td><td>Intermediate polarity porous polymer<\/td><td>Neutral solvents, ketones, esters, and hydrocarbons; baseline separation of ethane, ethene, and acetylene<\/td><td>GS-Q<\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1755\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-S-BOND<\/strong><\/a><br>(intermediate polarity porous polymer)<\/td><td><\/td><td>DVB vinylpyridine polymer<\/td><td>Light gases in ethylene and propylene; ketones, esters, hydrocarbons<\/td><td>PoraPLOT S<\/td><td><\/td><td><\/td><\/tr><tr><td><a href=\"https:\/\/www.restek.com\/c\/1756\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-U-BOND<\/strong><\/a><br>(polar porous ploymer)<\/td><td>G45<\/td><td>DVB ethylene glycol-dimethylacrylate polymer<\/td><td>More retention for polar compounds; trace H<sub>2<\/sub>S, COS, and mercaptans in hydrocarbon streams<\/td><td>HP PLOT U,<br>PoraBOND U,<br>PoraPLOT U<\/td><td><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>If you\u2019re running other applications, use our <a href=\"https:\/\/ez.restek.com\/proezgc\" target=\"_blank\" rel=\"noopener\">Pro <em>EZ<\/em>GC Chromatogram Modeler<\/a> to find the best Restek GC column for your analyte list.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Columns by phase cross-reference chart for GC columns.<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[462],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-60180","post","type-post","status-publish","format-standard","hentry","category-articles-fr"],"acf":[],"taxonomy_info":{"category":[{"value":462,"label":"Articles"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":462,"name":"Articles","slug":"articles-fr","term_group":0,"term_taxonomy_id":462,"taxonomy":"category","description":"","parent":0,"count":459,"filter":"raw","cat_ID":462,"category_count":459,"category_description":"","cat_name":"Articles","category_nicename":"articles-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/60180","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=60180"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/60180\/revisions"}],"predecessor-version":[{"id":74213,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/60180\/revisions\/74213"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=60180"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=60180"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=60180"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=60180"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=60180"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=60180"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=60180"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=60180"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=60180"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}