{"id":75773,"date":"2023-09-11T21:19:00","date_gmt":"2023-09-11T21:19:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=75773"},"modified":"2026-08-11T16:57:49","modified_gmt":"2026-08-11T16:57:49","slug":"is-xylazine-just-the-beginning-two-more-veterinary-drugs-found-in-illicit-drug-supply","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/blogs-ja\/is-xylazine-just-the-beginning-two-more-veterinary-drugs-found-in-illicit-drug-supply\/","title":{"rendered":"Is Xylazine Just the Beginning? \u2014Two More Veterinary Drugs Found in Illicit Drug Supply"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">In my previous post, I wrote a blog about the veterinary tranquilizer xylazine and the dangers it poses as a toxic adulterant in the illicit drug market (<a href=\"https:\/\/discover.restek.com\/gnbl4875\/why-is-everyone-talking-about-xylazine\/\" data-type=\"post\" data-id=\"51865\">Why is Everyone Talking About Xylazine?<\/a>). In the time since, two more veterinary drugs\u2014phenylbutazone and medetomidine\u2014have also been identified in illicit drug materials. While these substances have not yet proliferated the illicit drug supply as xylazine has, we could see them continue to increase in popularity in a similar manner.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Phenylbutazone is a non-steroidal anti-inflammatory drug (NSAID) that has analgesic and anti-inflammatory properties commonly used for the short-term treatment of pain and fevers in animals<sup>1<\/sup>. It was originally used in humans to treat rheumatoid arthritis and gout but is no longer approved for any human use after harmful side effects were discovered<sup>1<\/sup>. Adverse effects of phenylbutazone use can range from dizziness, headaches, and nausea to gastrointestinal bleeding, liver and kidney damage, and blood disorders which can lead to death<sup>2<\/sup>. Medetomidine is a drug also used for veterinary purposes, primarily as an anesthetic. Medetomidine is a racemic mixture of dexmedetomidine and levomedetomidine, with dexmedetomidine being the active component.<sup>3<\/sup>&nbsp;The effects of medetomidine in humans are not well studied.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong>\u00a0Phenylbutazone<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image75773_328c8e-fa .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image75773_328c8e-fa\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"273\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-is-xylazine-just-the-beginning-01.png\" alt=\"\" class=\"kb-img wp-image-75792\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-is-xylazine-just-the-beginning-01.png 500w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-is-xylazine-just-the-beginning-01-300x164.png 300w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong>\u00a0Medetomidine<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image75773_e1352d-f8 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image75773_e1352d-f8\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"273\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-is-xylazine-just-the-beginning-02.png\" alt=\"\" class=\"kb-img wp-image-75786\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-is-xylazine-just-the-beginning-02.png 500w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-is-xylazine-just-the-beginning-02-300x164.png 300w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\">Phenylbutazone and medetomidine have been detected alongside a number of illicit drugs, including heroin, fentanyl, xylazine, acetyl fentanyl, para-fluorofentanyl, diphenhydramine, and other adulterants<sup>2,3<\/sup>. Much like I discussed in my xylazine blog, incorporating these two compounds into laboratory testing scopes is going to be a growing need. In the xylazine blog, we looked at adding the compound to an already developed, high-throughput drugs of abuse assay as a method of testing for xylazine. With phenylbutazone and medetomidine, I wanted to develop a new, rapid LC-MS\/MS method that included these two analytes and the other drugs they are commonly found with.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To start developing a new method, normally I would head into the lab and start experimenting with columns, mobile phases, and gradients until I had a working chromatography method. Instead of this, I decided to use Restek\u2019s Pro EZLC Chromatogram Modeler (<a href=\"https:\/\/discover.restek.com\/articles\/GNOT3446\/pro-ezlc-online-tools\/\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/articles\/GNOT3446\/pro-ezlc-online-tools\/\">Pro EZLC Online Tools<\/a>) to do all the hard work for me. Pro EZLC is a virtual liquid chromatography modeler that can be used to develop and optimize LC methods without any hands-on time in the lab. I selected my compound list, made some changes based on the column I was using, and optimized the chromatography gradient until I was satisfied with the separation. Pro EZLC produced the method shown below.\u00a0<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong>\u00a0LC-MS\/MS Method Generated by Pro EZLC Chromatogram Modeler<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image75773_bae85c-e8 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image75773_bae85c-e8\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"954\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-is-xylazine-just-the-beginning-03-954x1024.png\" alt=\"\" class=\"kb-img wp-image-75780\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-is-xylazine-just-the-beginning-03-954x1024.png 954w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-is-xylazine-just-the-beginning-03-280x300.png 280w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-is-xylazine-just-the-beginning-03-768x824.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-is-xylazine-just-the-beginning-03.png 1000w\" sizes=\"auto, (max-width: 954px) 100vw, 954px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\">Using the method EZLC supplied me with, I ran a sample containing all the analytes on an LC-MS\/MS. The following chromatogram was generated.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4:<\/strong>\u00a0Chromatogram Generated Using Pro EZLC Chromatogram Modeler Method on LC-MS\/MS System<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image75773_bed354-2e .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image75773_bed354-2e\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"346\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-is-xylazine-just-the-beginning-04.png\" alt=\"\" class=\"kb-img wp-image-75774\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-is-xylazine-just-the-beginning-04.png 1000w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-is-xylazine-just-the-beginning-04-300x104.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-is-xylazine-just-the-beginning-04-768x266.png 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><strong>Table 1:<\/strong>&nbsp;Experimental Analyte Retention Times<\/p>\n\n\n<figure class=\"wp-block-table\">\n<table style=\"border-style: none;\">\n<tbody>\n<tr style=\"text-align: center;\">\n<td><strong>Peak #<\/strong><\/td>\n<td><strong>Analyte<\/strong><\/td>\n<td><strong>T<sub>R<\/sub>\u00a0(min)<\/strong><\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1; text-align: center;\">\n<td>1<\/td>\n<td>Xylazine<\/td>\n<td>0.94<\/td>\n<\/tr>\n<tr style=\"text-align: center;\">\n<td>2<\/td>\n<td>Heroin<\/td>\n<td>1.09<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1; text-align: center;\">\n<td>3<\/td>\n<td>Medetomidine<\/td>\n<td>1.29<\/td>\n<\/tr>\n<tr style=\"text-align: center;\">\n<td>4<\/td>\n<td>Acetyl fentanyl<\/td>\n<td>1.61<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1; text-align: center;\">\n<td>5<\/td>\n<td>Diphenhydramine<\/td>\n<td>1.72<\/td>\n<\/tr>\n<tr style=\"text-align: center;\">\n<td>6<\/td>\n<td><em>para<\/em>-Fluorofentanyl<\/td>\n<td>1.87<\/td>\n<\/tr>\n<tr style=\"background-color: #ecf0f1; text-align: center;\">\n<td>7<\/td>\n<td>Fentanyl<\/td>\n<td>1.94<\/td>\n<\/tr>\n<tr style=\"text-align: center;\">\n<td>8<\/td>\n<td>Phenylbutazone<\/td>\n<td>3. 46<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<p class=\"wp-block-paragraph\">The experimental results match up very well with what EZLC predicted, with an average difference in retention time of 6.7 seconds between the observed and expected values. This method which analyzes for newly trending toxic adulterants and common drugs of abuse demonstrates how Pro EZLC can be used to develop methods in a fraction of the time it would usually require. Pro EZLC is an especially valuable tool when working with compounds like medetomidine and phenylbutazone, which may not be routinely tested for by many laboratories at this point.&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">References<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Lees, Peter, and Pierre-Louis Toutain. \u201cPharmacokinetics, Pharmacodynamics, Metabolism, Toxicology and Residues of Phenylbutazone in Humans and Horses.\u201d&nbsp;<em>Veterinary Journal<\/em>, vol. 196, no. 3, Elsevier BV, June 2013, pp. 294\u2013303. https:\/\/doi.org\/10.1016\/j.tvjl.2013.04.019.<\/li>\n\n\n\n<li>Shuda, Sarah A., M. S., et al. \u201cPhenylbutazone: A Toxic Adulterant Found in Illicit Street Drugs.\u201d&nbsp;<em>The Center for Forensic Science Research and Education<\/em>, Mar. 2023.<\/li>\n\n\n\n<li>\u201cAnnouncement of an Emerging Compound: Medetomidine.\u201d&nbsp;<em>National Forensic Laboratory Information<\/em>&nbsp;System, 2023.<\/li>\n<\/ol>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>In my previous post, I wrote a blog about the veterinary tranquilizer xylazine and the dangers it poses as a toxic adulterant in the illicit drug market (Why is Everyone Talking About Xylazine?). In the time since, two more veterinary drugs\u2014phenylbutazone and medetomidine\u2014have also been identified in illicit drug materials. While these substances have not&#8230;<\/p>\n","protected":false},"author":13,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[432],"class_list":["post-75773","post","type-post","status-publish","format-standard","hentry","category-blogs-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}]},"featured_image_src_large":false,"author_info":{"display_name":"Haley Berkland, MS","author_link":"https:\/\/discover.restek.com\/fr\/author\/haley-berkland-ms\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":432,"user_id":13,"is_guest":0,"slug":"haley-berkland-ms","display_name":"Haley Berkland, MS","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg"},"author_category":"1","first_name":"Haley","last_name":"Berkland","user_url":"https:\/\/www.linkedin.com\/in\/haley-berkland-60b66517b\/","job_title":"LC Applications Scientist","description":"Haley is an LC applications scientist at Restek. She attended Duquesne University, receiving her bachelor's degree in biochemistry and a master's degree in forensic science and law. As a graduate student, she performed research on the detection of drugs of abuse in vitreous humor by LC-MS\/MS. Before joining Restek in 2023, Haley spent four years working as a forensic toxicologist. While in this role, she performed analysis of postmortem toxicology casework, identification of seized drug evidence, and development\/validation of new assays by LC-MS\/MS, GC-MS, and GC-FID."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/75773","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=75773"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/75773\/revisions"}],"predecessor-version":[{"id":83504,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/75773\/revisions\/83504"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=75773"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=75773"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=75773"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=75773"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=75773"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=75773"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=75773"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=75773"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=75773"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}