{"id":76485,"date":"2022-08-29T00:00:00","date_gmt":"2022-08-29T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=76485"},"modified":"2026-01-28T19:24:14","modified_gmt":"2026-01-28T19:24:14","slug":"des-analyses-de-semi-volatils-plus-rapides-sans-sacrifier-les-separations-critiques-avec-le-logiciel-de-transfert-de-methodes-ezgc-et-une-colonne-rxi-svocms","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/blog-fr\/gnbl5538-fr\/des-analyses-de-semi-volatils-plus-rapides-sans-sacrifier-les-separations-critiques-avec-le-logiciel-de-transfert-de-methodes-ezgc-et-une-colonne-rxi-svocms","title":{"rendered":"Des analyses de semi-volatils plus rapides sans sacrifier les s\u00e9parations critiques avec le logiciel de transfert de m\u00e9thodes EZGC et une colonne Rxi-SVOCms"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Dans mon dernier article, je soulignais l\u2019importance de la s\u00e9paration <a href=\"https:\/\/discover.restek.com\/fr\/blog-fr\/gnbl5506-fr\/separation-amelioree-de-l-indeno123-cdpyrene-et-du-dibenzahanthracene-sur-la-nouvelle-colonne-rxi-svocms\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/fr\/blog-fr\/gnbl5506-fr\/separation-amelioree-de-l-indeno123-cdpyrene-et-du-dibenzahanthracene-sur-la-nouvelle-colonne-rxi-svocms\">indeno[123-cd]pyr\u00e8ne-dibenz[ah]anthrac\u00e8ne<\/a> et promettais de r\u00e9duire les les temps d\u2019analyse sans sacrifier les s\u00e9parations critiques. Plus important, il s\u2019agit de maintenir le m\u00eame profil d&#8217;\u00e9lution qu\u2019avec le cycle d\u2019origine de 16 minutes. Le logiciel de transfert de m\u00e9thodes EZGC est un outil pratique pour transf\u00e9rer les param\u00e8tres d\u2019acquisition d\u2019une colonne \u00e0 une autre, tout en pr\u00e9servant les temp\u00e9ratures d\u2019\u00e9lution des analytes et les temps de r\u00e9tention relatifs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c0 partir des param\u00e8tres du <a href=\"https:\/\/fr.restek.com\/chromatogram-detail\/GC_EV1604\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/fr.restek.com\/chromatogram-detail\/GC_EV1604\" rel=\"noreferrer noopener\">GC_EV1604<\/a>, le chromatogramme du m\u00e9lange 8270 MegaMix sur une colonne Rxi-SVOCms de 30 m x 0,25 mm x 0,25 \u00b5m (<a href=\"https:\/\/fr.restek.com\/p\/16623\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/fr.restek.com\/p\/16623\" rel=\"noreferrer noopener\">r\u00e9f. 16623<\/a>), le logiciel de transfert de m\u00e9thodes EZGC permet de g\u00e9n\u00e9rer les param\u00e8tres d\u2019acquisition pour une colonne Rxi-SVOCms de 20 m x 0,15 mm x 0,15 \u00b5m (<a href=\"https:\/\/fr.restek.com\/p\/46616\" data-type=\"link\" data-id=\"https:\/\/fr.restek.com\/p\/46616\" target=\"_blank\" rel=\"noopener\">r\u00e9f. 46616<\/a>). L&#8217;interface du <a href=\"https:\/\/ez.restek.com\/ezgc-mtfc\/fr\" target=\"_blank\" rel=\"noopener\">logiciel de transfert de m\u00e9thodes <em>EZ<\/em>GC<\/a> est repr\u00e9sent\u00e9e dans la Figure 1. Il est important de s\u00e9lectionner &#8220;Traduction&#8221; dans la section\u00a0<strong>R\u00e9sultats<\/strong> pour obtenir une traduction fid\u00e8le du contenu.<\/p>\n\n\n<style>.kb-image76485_f7fb0b-0b .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image76485_f7fb0b-0b size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"488\" height=\"849\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-01_fr.png\" alt=\"\" class=\"kb-img wp-image-78688\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-01_fr.png 488w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-01_fr-172x300.png 172w\" sizes=\"auto, (max-width: 488px) 100vw, 488px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Figure 1 &#8211; Passage d\u2019une colonne de 30 m x 0,25 mm x 0,25 \u00b5m \u00e0 une colonne de 20 m x 0,15 mm x 0,15 \u00b5m avec le logiciel de transfert de m\u00e9thodes EZGC.<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">R\u00e9duire un temps d\u2019analyse de 70% par rapport au temps initial, tout en maintenant le profil d&#8217;\u00e9lution, cela semble trop beau pour \u00eatre vrai. Pourtant, c\u2019est possible, car les efficacit\u00e9s respectives des colonnes de 30 m x 0,25 mm x 0,25 \u00b5m et de 20 m x 0,15 mm x 0,15 \u00b5m utilis\u00e9es sont tr\u00e8s similaires. Les deux colonnes pr\u00e9sentent plus de 130\u00a0000 plateaux th\u00e9oriques. Mais la th\u00e9orie se refl\u00e8te aussi dans les conditions analytiques r\u00e9elles. Les Figures 2 et 3 sont les chromatogrammes du m\u00e9lange 8270 MegaMix obtenus avec les colonnes Rxi-SVOCms de 30 m <a href=\"https:\/\/fr.restek.com\/p\/16623\" data-type=\"link\" data-id=\"https:\/\/fr.restek.com\/p\/16623\" target=\"_blank\" rel=\"noopener\">r\u00e9f. 16623<\/a> et 20 m <a href=\"https:\/\/fr.restek.com\/p\/46616\" data-type=\"link\" data-id=\"https:\/\/fr.restek.com\/p\/46616\" target=\"_blank\" rel=\"noopener\">r\u00e9f. 46616<\/a>, respectivement.<\/p>\n\n\n<style>.kb-image76485_d76f1d-d9 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image76485_d76f1d-d9 size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"583\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-03-1024x583.png\" alt=\"\" class=\"kb-img wp-image-78645\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-03-1024x583.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-03-300x171.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-03-768x437.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-03.png 1265w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Figure 2 &#8211; 8270 MegaMix sur colonne Rxi-SVOCms de 30 m x 0,25 mm x 0,25 \u00b5m<\/em><\/p>\n\n\n<style>.kb-image76485_bd1cc5-a6 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image76485_bd1cc5-a6 size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"590\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-04a-1024x590.png\" alt=\"\" class=\"kb-img wp-image-78639\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-04a-1024x590.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-04a-300x173.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-04a-768x443.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-04a.png 1259w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Figure 3 &#8211; 8270 MegaMix sur colonne Rxi-SVOCms de 20 m x 0,15 mm x 0,15 \u00b5m<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Encore plus impressionnant, le profil d&#8217;\u00e9lution et les s\u00e9parations critiques repr\u00e9sent\u00e9s dans la Figure 3 sont tr\u00e8s proches de ceux du mod\u00e9lisateur de chromatogpour respecter ces rampes de mani\u00e8re constante. Nous recommandons une injection &#8220;split&#8221; 20:1 avec les colonnes de DI \u2264 0,18 mm. Cela permet d\u2019obtenir des performances \u00e9quivalentes \u00e0 une injection &#8220;split&#8221; 10:1 sur une colonne de DI 0,25 mm avec le m\u00eame insert d&#8217;injection et les m\u00eames \u00e9talons.&nbsp;<span style=\"color: #ff0000;\">Un rapport de split doubl\u00e9 permet de diviser par 2 la contamination de la colonne, pouvant ainsi allonger la dur\u00e9e de vie de la colonne par rapport \u00e0 des colonnes comparables avec le m\u00eame nombre d&#8217;\u00e9chantillons analys\u00e9s.<\/span><\/p>\n\n\n<style>.kb-image76485_43dcfd-40 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image76485_43dcfd-40 size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"456\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-05-1024x456.png\" alt=\"\" class=\"kb-img wp-image-78633\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-05-1024x456.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-05-300x133.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-05-768x342.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-05.png 1142w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Figure 4 &#8211; Kit de calibration 8270 Annexe IX mod\u00e9lis\u00e9 pour une colonne Rxi-SVOCms\u00a0<a href=\"https:\/\/fr.restek.com\/p\/46616\" data-type=\"link\" data-id=\"https:\/\/fr.restek.com\/p\/46616\" target=\"_blank\" rel=\"noopener\">r\u00e9f. 46616<\/a> avec le mod\u00e9lisateur de chromatogramme Pro EZGC.<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En sacrifiant l\u00e9g\u00e8rement l&#8217;efficacit\u00e9 de la colonne (environ 15 000 plateaux), il est possible de passer \u00e0 une colonne Rxi-SVOCms de 20m x 0,18 mm x 0,18 \u00b5m\u00a0 (<a href=\"https:\/\/fr.restek.com\/p\/46602\" data-type=\"link\" data-id=\"https:\/\/fr.restek.com\/p\/46602\" target=\"_blank\" rel=\"noopener\">r\u00e9f. 46602<\/a>) \u00a0en utilisant le logiciel de transfert de m\u00e9thodes EZGC (Figure 5). Ainsi, le temps d&#8217;\u00e9lution du benzo[ghi]peryl\u00e8ne est diminu\u00e9 de 5,6 minutes par rapport \u00e0 la colonne Rxi-SVOCms de 30m (Figure 6). Le kit &#8220;Oven Accelerator&#8221; est quasi-certainement n\u00e9cessaire pour respecter ces mont\u00e9es en temp\u00e9rature plus rapides avec les GC Agilent 110v.<\/p>\n\n\n<style>.kb-image76485_640df5-2d .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image76485_640df5-2d size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"488\" height=\"849\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-01_fr.png\" alt=\"\" class=\"kb-img wp-image-78688\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-01_fr.png 488w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-01_fr-172x300.png 172w\" sizes=\"auto, (max-width: 488px) 100vw, 488px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Figure 5 &#8211; Passage d\u2019une colonne de 30 m x 0,25 mm x 0,25 \u00b5m \u00e0 20 m x 0,18 mm x 0,18 \u00b5m avec le logiciel de transfert de m\u00e9thodes EZGC.<\/em><\/p>\n\n\n<style>.kb-image76485_fb881d-88 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image76485_fb881d-88 size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"514\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-06-1024x514.png\" alt=\"\" class=\"kb-img wp-image-78621\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-06-1024x514.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-06-300x151.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-06-768x386.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-06.png 1282w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Figure 6 &#8211; Chromatogramme du 8270 MegaMix sur colonne Rxi-SVOCms de 20 m x 0,18 mm x 0,18 \u00b5m\u00a0(<a href=\"https:\/\/fr.restek.com\/p\/46602\" data-type=\"link\" data-id=\"https:\/\/fr.restek.com\/p\/46602\" target=\"_blank\" rel=\"noopener\">r\u00e9f. 46602<\/a>)<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">En associant le <a href=\"https:\/\/fr.restek.com\/p\/23849\" data-type=\"link\" data-id=\"https:\/\/fr.restek.com\/p\/23849\" target=\"_blank\" rel=\"noopener\">kit &#8220;Oven Accelerator&#8221;<\/a> \u00e0 un four 208v (ou version sup\u00e9rieure) \u00e0 mont\u00e9e en temp\u00e9rature rapide, il est possible de recourir \u00e0 des transferts de flux \u00e0 vitesse optimis\u00e9e pour des analyses de semi-volatils inf\u00e9rieures \u00e0 10 minutes, mais c\u2019est un sujet qui m\u00e9rite un article diff\u00e9rent.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Produits mentionn\u00e9s<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/16623\">                                R\u00e9f. 16623                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Colonne capillaire Rxi-SVOCms, L 30\u00a0m, DI 0.25 mm, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/16623\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23849\">                                R\u00e9f. 23849                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Kit \u00ab\u00a0Oven Accelerator\u00a0\u00bb, pour GC Agilent 5890, 6890, 7890 et 8890<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23849\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/46616\">                                R\u00e9f. 46616                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Colonne capillaire Rxi-SVOCms, L 20\u00a0m, DI 0.15\u00a0mm, 0.15 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/46616\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/46602\">                                R\u00e9f. 46602                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Colonne capillaire Rxi-SVOCms, L 20\u00a0m, DI 0.18\u00a0mm, 0.18 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/46602\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Pr&eacute;c&eacute;demment, j&#8217;ai termin&eacute; mon explication sur l&#8217;importance de l&#8217;ind&eacute;no[123-cd]pyr&egrave;ne-dibenz[ah]anthrac&egrave;ne en promettant de vous montrer comment r&eacute;duire de 5 minutes l&#8217;analyse sans sacrifier les s&eacute;parations critiques. Plus important encore, nous conservons le m&ecirc;me profil d&#8217;&eacute;lution que lors de l&#8217;analyse de 16 minutes. Le logiciel de transfert de m&eacute;thodes <em>EZ<\/em>GC est un outil pratique pour transf&eacute;rer les param&egrave;tres d&rsquo;acquisition d&rsquo;une colonne &agrave; une autre, tout en pr&eacute;servant les temp&eacute;ratures d&rsquo;&eacute;lution des analytes et les temps de r&eacute;tention relatifs.<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[791],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-76485","post","type-post","status-publish","format-standard","hentry","category-blog-fr"],"acf":[],"taxonomy_info":{"category":[{"value":791,"label":"Blog"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":791,"name":"Blog","slug":"blog-fr","term_group":0,"term_taxonomy_id":791,"taxonomy":"category","description":"","parent":0,"count":432,"filter":"raw","cat_ID":791,"category_count":432,"category_description":"","cat_name":"Blog","category_nicename":"blog-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/76485","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=76485"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/76485\/revisions"}],"predecessor-version":[{"id":85670,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/76485\/revisions\/85670"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=76485"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=76485"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=76485"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=76485"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=76485"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=76485"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=76485"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=76485"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=76485"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}