{"id":80225,"date":"2026-01-19T19:42:04","date_gmt":"2026-01-19T19:42:04","guid":{"rendered":"https:\/\/discover.restek.com\/?p=80225"},"modified":"2026-03-31T09:29:10","modified_gmt":"2026-03-31T09:29:10","slug":"optimisez-la-productivite-de-votre-laboratoire-grace-a-une-methode-etendue-pour-lanalyse-des-semi-volatils-a-letat-de-traces","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/articles-fr\/evfa5253-fr\/optimisez-la-productivite-de-votre-laboratoire-grace-a-une-methode-etendue-pour-lanalyse-des-semi-volatils-a-letat-de-traces","title":{"rendered":"Optimisez la productivit\u00e9 de votre laboratoire gr\u00e2ce \u00e0 une m\u00e9thode \u00e9tendue pour l\u2019analyse des semi-volatils \u00e0 l\u2019\u00e9tat de traces"},"content":{"rendered":"\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong><em>\u00c9l\u00e9ments cl\u00e9s<\/em><\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>La d\u00e9sactivation innovante TriMax offre un circuit d\u2019\u00e9chantillon robuste et hautement inerte pour 150 compos\u00e9s acides, basiques et neutres.<\/li>\n\n\n\n<li>Son inertie optimale offre une meilleure forme de pics pour une large gamme de compos\u00e9s semi-volatils, des m\u00e9thodes consolid\u00e9es et une sensibilit\u00e9 de l\u2019ordre du picogramme.<\/li>\n\n\n\n<li>Plus de flexibilit\u00e9&nbsp;: appliquez notre m\u00e9thode pour 150 compos\u00e9s semi-volatils ou optimisez les conditions pour votre propre liste d\u2019analytes en quelques secondes avec notre mod\u00e9lisateur de chromatogramme gratuit <em>EZ<\/em>GC.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/explore.restek.com\/RMX-contact-technical-service-fr\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"127\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE_FR-768x127-2.png\" alt=\"\" class=\"wp-image-83951\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE_FR-768x127-2.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE_FR-768x127-2-300x50.png 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/a><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/explore.restek.com\/RMX-contact-sales-fr\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"127\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-FR-768x127-1.png\" alt=\"\" class=\"wp-image-83957\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-FR-768x127-1.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-FR-768x127-1-300x50.png 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/a><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">L\u2019analyse des compos\u00e9s semi-volatils est une application importante pour les laboratoires d\u2019analyses environnementales du monde entier. En raison de la diversit\u00e9 de leur composition chimique et de leur r\u00e9activit\u00e9, ces compos\u00e9s semi-volatils sont souvent analys\u00e9s sur diff\u00e9rentes colonnes, ce qui signifie que des gains de productivit\u00e9 significatifs sont possibles en regroupant les m\u00e9thodes sur une seule colonne. Toutefois, la consolidation r\u00e9ussie des m\u00e9thodes repose sur l\u2019efficacit\u00e9 de la d\u00e9sactivation de la colonne GC&nbsp;; les d\u00e9sactivations classiques sont souvent performantes pour certaines classes de compos\u00e9s mais pas pour toutes. Restek a d\u00e9velopp\u00e9 la d\u00e9sactivation de nouvelle g\u00e9n\u00e9ration TriMax, qui est appliqu\u00e9e sur toutes les colonnes RMX. Elle s\u2019est r\u00e9v\u00e9l\u00e9e efficace pour une large gamme de compos\u00e9s et offre de meilleures performances que les colonnes concurrentes, m\u00eame celles proposant une d\u00e9sactivation Premium [1].<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Une \u00e9tude r\u00e9cente a montr\u00e9 que les colonnes RMX-5Sil MS produisaient des pics plus sym\u00e9triques pour une plus large gamme de classes de compos\u00e9s semi-volatils. Les exigences relatives \u00e0 la qualit\u00e9 des donn\u00e9es \u00e9taient donc respect\u00e9es pour un plus grand nombre de compos\u00e9s en termes de lin\u00e9arit\u00e9 et de taux de r\u00e9cup\u00e9ration [2]. La pr\u00e9sente application s\u2019appuie sur ce travail fondamental en optimisant les conditions analytiques et en \u00e9largissant la liste des compos\u00e9s-cibles \u00e0 150 compos\u00e9s semi-volatils couramment analys\u00e9s, y compris les \u00e9talons internes et les \u00e9talons de substitution (Figure&nbsp;1).La Figure&nbsp;2 montre que d\u2019excellents r\u00e9sultats ont \u00e9t\u00e9 obtenus &nbsp;\u00e0 des niveaux de traces (0,1 \u00e0 10 pg &#8220;on-column&#8221;) pour les &nbsp;compos\u00e9s semi-volatils de toutes les classes, notamment les compos\u00e9s r\u00e9actifs acides (pentachloroph\u00e9nol, 2,4-Dinitroph\u00e9nol) et basiques (pyridine, benzidine). Pour ces compos\u00e9s, la conformit\u00e9 du syst\u00e8me est souvent soumise \u00e0 des exigences de qualit\u00e9 des donn\u00e9es. En outre, la colonne RMX-5Sil MS a permis une s\u00e9paration efficace des hydrocarbures aromatiques polycycliques neutres difficiles \u00e0 s\u00e9parer (benzo[b] et [k]fluoroanth\u00e8ne).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cette m\u00e9thode d\u2019analyse d\u00e9velopp\u00e9e pour les compos\u00e9s semi-volatils \u00e0 l&#8217;\u00e9tat de traces montre l\u2019efficacit\u00e9 de la colonne RMX-5Sil MS pour une liste de 150 compos\u00e9s semi-volatils couramment analys\u00e9s (r\u00e9f. 31907). Les laboratoires peuvent aussi l\u2019adapter \u00e0 leurs besoins en utilisant notre mod\u00e9lisateur de chromatogramme Pro <em>EZ<\/em>GC. Cet outil de mod\u00e9lisation permet de&nbsp;g\u00e9n\u00e9rer instantan\u00e9ment des m\u00e9thodes optimis\u00e9es en fonction de leurs listes d\u2019analytes sp\u00e9cifiques et des dimensions de colonnes choisies.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-image80225_8ab586-44 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image80225_8ab586-44\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/www.restek.com\/c\/1484\" class=\"kb-advanced-image-link\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"177\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/RMX-Graphic-Ad-HTML-Block-with-Topaz-Liners_FR-1024x177.png\" alt=\"\" class=\"kb-img wp-image-91728\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-HTML-Block-with-Topaz-Liners_FR-1024x177.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-HTML-Block-with-Topaz-Liners_FR-300x52.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-HTML-Block-with-Topaz-Liners_FR-768x133.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-HTML-Block-with-Topaz-Liners_FR.png 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1 : <\/strong>M\u00e9thode \u00e9tendue pour l\u2019analyse de traces de 150 compos\u00e9s semi-volatils, \u00e9talons de substitution et \u00e9talons internes \u00e0 100\u00a0ppb (10 pg &#8220;On-Column&#8221;)<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1527.png\" alt=\"Semivolatiles on RMX-5Sil MS by GC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1527<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Mass 1<\/th><th style=\"text-align: center;width: 75px\">Product 1<\/th><th style=\"text-align: center;width: 75px\">Collision energy 1<\/th><th style=\"text-align: center;width: 75px\">Mass 2<\/th><th style=\"text-align: center;width: 75px\">Product 2<\/th><th style=\"text-align: center;width: 75px\">Collision energy 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Dioxane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/123-91-1\/1,4-Dioxane\" target=\"_blank\" rel=\"noopener\">1,4-Dioxane<\/a><\/td><td class=\"oth\">2.71<\/td><td class=\"oth\">10<\/td><td class=\"oth\">58<\/td><td class=\"oth\">28<\/td><td class=\"oth\">6<\/td><td class=\"oth\">88<\/td><td class=\"oth\">28<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosodimethylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62-75-9\/N-Nitrosodimethylamine\" target=\"_blank\" rel=\"noopener\">N-Nitrosodimethylamine<\/a><\/td><td class=\"oth\">3.02<\/td><td class=\"oth\">10<\/td><td class=\"oth\">74<\/td><td class=\"oth\">44<\/td><td class=\"oth\">6<\/td><td class=\"oth\">74<\/td><td class=\"oth\">42<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyridine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110-86-1\/Pyridine\" target=\"_blank\" rel=\"noopener\">Pyridine<\/a><\/td><td class=\"oth\">3.08<\/td><td class=\"oth\">10<\/td><td class=\"oth\">79<\/td><td class=\"oth\">52<\/td><td class=\"oth\">12<\/td><td class=\"oth\">52<\/td><td class=\"oth\">26<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethyl methacrylate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/97-63-2\/Ethyl methacrylate\" target=\"_blank\" rel=\"noopener\">Ethyl methacrylate<\/a><\/td><td class=\"oth\">3.51<\/td><td class=\"oth\">10<\/td><td class=\"oth\">69<\/td><td class=\"oth\">41<\/td><td class=\"oth\">6<\/td><td class=\"oth\">99<\/td><td class=\"oth\">43<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Picoline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/109-06-8\/2-Picoline\" target=\"_blank\" rel=\"noopener\">2-Picoline<\/a><\/td><td class=\"oth\">3.91<\/td><td class=\"oth\">10<\/td><td class=\"oth\">93<\/td><td class=\"oth\">66<\/td><td class=\"oth\">12<\/td><td class=\"oth\">93<\/td><td class=\"oth\">65<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosomethylethylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/10595-95-6\/N-Nitrosomethylethylamine\" target=\"_blank\" rel=\"noopener\">N-Nitrosomethylethylamine<\/a><\/td><td class=\"oth\">4<\/td><td class=\"oth\">10<\/td><td class=\"oth\">88<\/td><td class=\"oth\">71<\/td><td class=\"oth\">6<\/td><td class=\"oth\">88<\/td><td class=\"oth\">42<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl methanesulfonate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/66-27-3\/Methyl methanesulfonate\" target=\"_blank\" rel=\"noopener\">Methyl methanesulfonate<\/a><\/td><td class=\"oth\">4.39<\/td><td class=\"oth\">10<\/td><td class=\"oth\">80<\/td><td class=\"oth\">65<\/td><td class=\"oth\">8<\/td><td class=\"oth\">80<\/td><td class=\"oth\">48<\/td><td class=\"oth\">28<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\">Acrylamine<\/td><td class=\"oth\">4.44<\/td><td class=\"oth\">10<\/td><td class=\"oth\">71<\/td><td class=\"oth\">55<\/td><td class=\"oth\">6<\/td><td class=\"oth\">71<\/td><td class=\"oth\">44<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Fluorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/367-12-4\/2-Fluorophenol\" target=\"_blank\" rel=\"noopener\">2-Fluorophenol<\/a><\/td><td class=\"oth\">4.62<\/td><td class=\"oth\">10<\/td><td class=\"oth\">112<\/td><td class=\"oth\">92<\/td><td class=\"oth\">6<\/td><td class=\"oth\">92<\/td><td class=\"oth\">63<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosodiethylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/55-18-5\/N-Nitrosodiethylamine\" target=\"_blank\" rel=\"noopener\">N-Nitrosodiethylamine<\/a><\/td><td class=\"oth\">4.94<\/td><td class=\"oth\">10<\/td><td class=\"oth\">102<\/td><td class=\"oth\">85<\/td><td class=\"oth\">6<\/td><td class=\"oth\">102<\/td><td class=\"oth\">44<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethyl methanesulfonate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62-50-0\/Ethyl methanesulfonate\" target=\"_blank\" rel=\"noopener\">Ethyl methanesulfonate<\/a><\/td><td class=\"oth\">5.38<\/td><td class=\"oth\">10<\/td><td class=\"oth\">109<\/td><td class=\"oth\">45<\/td><td class=\"oth\">10<\/td><td class=\"oth\">109<\/td><td class=\"oth\">79<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzaldehyde\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-52-7\/Benzaldehyde\" target=\"_blank\" rel=\"noopener\">Benzaldehyde<\/a><\/td><td class=\"oth\">5.88<\/td><td class=\"oth\">10<\/td><td class=\"oth\">105<\/td><td class=\"oth\">77<\/td><td class=\"oth\">10<\/td><td class=\"oth\">105<\/td><td class=\"oth\">51<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenol-d6\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13127-88-3\/Phenol-d6\" target=\"_blank\" rel=\"noopener\">Phenol-d6<\/a><\/td><td class=\"oth\">6.02<\/td><td class=\"oth\">10<\/td><td class=\"oth\">99<\/td><td class=\"oth\">71<\/td><td class=\"oth\">8<\/td><td class=\"oth\">71<\/td><td class=\"oth\">42<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-95-2\/Phenol\" target=\"_blank\" rel=\"noopener\">Phenol<\/a><\/td><td class=\"oth\">6.04<\/td><td class=\"oth\">10<\/td><td class=\"oth\">94<\/td><td class=\"oth\">66<\/td><td class=\"oth\">10<\/td><td class=\"oth\">94<\/td><td class=\"oth\">39<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62-53-3\/Aniline\" target=\"_blank\" rel=\"noopener\">Aniline<\/a><\/td><td class=\"oth\">6.07<\/td><td class=\"oth\">10<\/td><td class=\"oth\">93<\/td><td class=\"oth\">66<\/td><td class=\"oth\">10<\/td><td class=\"oth\">93<\/td><td class=\"oth\">65<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachloroethane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-01-7\/Pentachloroethane\" target=\"_blank\" rel=\"noopener\">Pentachloroethane<\/a><\/td><td class=\"oth\">6.14<\/td><td class=\"oth\">10<\/td><td class=\"oth\">167<\/td><td class=\"oth\">132<\/td><td class=\"oth\">14<\/td><td class=\"oth\">167<\/td><td class=\"oth\">95<\/td><td class=\"oth\">32<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for bis-(2-Chloroethyl)ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111-44-4\/bis-(2-Chloroethyl)ether\" target=\"_blank\" rel=\"noopener\">bis-(2-Chloroethyl)ether<\/a><\/td><td class=\"oth\">6.18<\/td><td class=\"oth\">10<\/td><td class=\"oth\">93<\/td><td class=\"oth\">63<\/td><td class=\"oth\">6<\/td><td class=\"oth\">63<\/td><td class=\"oth\">27<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Chlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-57-8\/2-Chlorophenol\" target=\"_blank\" rel=\"noopener\">2-Chlorophenol<\/a><\/td><td class=\"oth\">6.25<\/td><td class=\"oth\">10<\/td><td class=\"oth\">128<\/td><td class=\"oth\">64<\/td><td class=\"oth\">14<\/td><td class=\"oth\">128<\/td><td class=\"oth\">63<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Decane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/124-18-5\/Decane\" target=\"_blank\" rel=\"noopener\">Decane<\/a><\/td><td class=\"oth\">6.4<\/td><td class=\"oth\">10<\/td><td class=\"oth\">85<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><td class=\"oth\">71<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,3-Dichlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/541-73-1\/1,3-Dichlorobenzene\" target=\"_blank\" rel=\"noopener\">1,3-Dichlorobenzene<\/a><\/td><td class=\"oth\">6.51<\/td><td class=\"oth\">10<\/td><td class=\"oth\">146<\/td><td class=\"oth\">111<\/td><td class=\"oth\">14<\/td><td class=\"oth\">146<\/td><td class=\"oth\">75<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Dichlorobenzene-d4\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3855-82-1\/1,4-Dichlorobenzene-d4\" target=\"_blank\" rel=\"noopener\">1,4-Dichlorobenzene-d4<\/a><\/td><td class=\"oth\">6.61<\/td><td class=\"oth\">10<\/td><td class=\"oth\">150<\/td><td class=\"oth\">115<\/td><td class=\"oth\">14<\/td><td class=\"oth\">150<\/td><td class=\"oth\">76<\/td><td class=\"oth\">38<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Dichlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-46-7\/1,4-Dichlorobenzene\" target=\"_blank\" rel=\"noopener\">1,4-Dichlorobenzene<\/a><\/td><td class=\"oth\">6.63<\/td><td class=\"oth\">10<\/td><td class=\"oth\">146<\/td><td class=\"oth\">111<\/td><td class=\"oth\">14<\/td><td class=\"oth\">146<\/td><td class=\"oth\">75<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzyl alcohol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-51-6\/Benzyl alcohol\" target=\"_blank\" rel=\"noopener\">Benzyl alcohol<\/a><\/td><td class=\"oth\">6.85<\/td><td class=\"oth\">10<\/td><td class=\"oth\">108<\/td><td class=\"oth\">79<\/td><td class=\"oth\">12<\/td><td class=\"oth\">108<\/td><td class=\"oth\">77<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,2-Dichlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-50-1\/1,2-Dichlorobenzene\" target=\"_blank\" rel=\"noopener\">1,2-Dichlorobenzene<\/a><\/td><td class=\"oth\">6.89<\/td><td class=\"oth\">10<\/td><td class=\"oth\">146<\/td><td class=\"oth\">111<\/td><td class=\"oth\">12<\/td><td class=\"oth\">111<\/td><td class=\"oth\">50<\/td><td class=\"oth\">36<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Indene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-13-6\/Indene\" target=\"_blank\" rel=\"noopener\">Indene<\/a><\/td><td class=\"oth\">7.05<\/td><td class=\"oth\">10<\/td><td class=\"oth\">115<\/td><td class=\"oth\">89<\/td><td class=\"oth\">16<\/td><td class=\"oth\">116<\/td><td class=\"oth\">89<\/td><td class=\"oth\">28<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Methylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-48-7\/2-Methylphenol\" target=\"_blank\" rel=\"noopener\">2-Methylphenol<\/a><\/td><td class=\"oth\">7.06<\/td><td class=\"oth\">10<\/td><td class=\"oth\">108<\/td><td class=\"oth\">80<\/td><td class=\"oth\">8<\/td><td class=\"oth\">108<\/td><td class=\"oth\">77<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,2&amp;apos;-oxybis(1-chloropropane)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-60-1\/2,2&amp;apos;-oxybis(1-chloropropane)\" target=\"_blank\" rel=\"noopener\">2,2&#8242;-oxybis(1-chloropropane)<\/a><\/td><td class=\"oth\">7.11<\/td><td class=\"oth\">10<\/td><td class=\"oth\">121<\/td><td class=\"oth\">45<\/td><td class=\"oth\">6<\/td><td class=\"oth\">77<\/td><td class=\"oth\">51<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosopyrrolidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/930-55-2\/N-Nitrosopyrrolidine\" target=\"_blank\" rel=\"noopener\">N-Nitrosopyrrolidine<\/a><\/td><td class=\"oth\">7.28<\/td><td class=\"oth\">10<\/td><td class=\"oth\">100<\/td><td class=\"oth\">43<\/td><td class=\"oth\">8<\/td><td class=\"oth\">100<\/td><td class=\"oth\">55<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">29.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetophenone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/98-86-2\/Acetophenone\" target=\"_blank\" rel=\"noopener\">Acetophenone<\/a><\/td><td class=\"oth\">7.31<\/td><td class=\"oth\">10<\/td><td class=\"oth\">105<\/td><td class=\"oth\">77<\/td><td class=\"oth\">12<\/td><td class=\"oth\">105<\/td><td class=\"oth\">51<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">30.<\/td><td class=\"cmpd\">3- and 4-Methylphenol<\/td><td class=\"oth\">7.33<\/td><td class=\"oth\">10<\/td><td class=\"oth\">70<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><td class=\"oth\">107<\/td><td class=\"oth\">77<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">31.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosomorpholine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59-89-2\/N-Nitrosomorpholine\" target=\"_blank\" rel=\"noopener\">N-Nitrosomorpholine<\/a><\/td><td class=\"oth\">7.331<\/td><td class=\"oth\">10<\/td><td class=\"oth\">116<\/td><td class=\"oth\">86<\/td><td class=\"oth\">6<\/td><td class=\"oth\">116<\/td><td class=\"oth\">56<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">32.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for o-Toluidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-53-4\/o-Toluidine\" target=\"_blank\" rel=\"noopener\">o-Toluidine<\/a><\/td><td class=\"oth\">7.37<\/td><td class=\"oth\">10<\/td><td class=\"oth\">106<\/td><td class=\"oth\">79<\/td><td class=\"oth\">8<\/td><td class=\"oth\">107<\/td><td class=\"oth\">77<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">33.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachloroethane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/67-72-1\/Hexachloroethane\" target=\"_blank\" rel=\"noopener\">Hexachloroethane<\/a><\/td><td class=\"oth\">7.49<\/td><td class=\"oth\">10<\/td><td class=\"oth\">201<\/td><td class=\"oth\">166<\/td><td class=\"oth\">12<\/td><td class=\"oth\">201<\/td><td class=\"oth\">131<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">34.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nitrobenzene-d5\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/4165-60-0\/Nitrobenzene-d5\" target=\"_blank\" rel=\"noopener\">Nitrobenzene-d5<\/a><\/td><td class=\"oth\">7.57<\/td><td class=\"oth\">10<\/td><td class=\"oth\">128<\/td><td class=\"oth\">82<\/td><td class=\"oth\">12<\/td><td class=\"oth\">82<\/td><td class=\"oth\">54<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">35.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/98-95-3\/Nitrobenzene\" target=\"_blank\" rel=\"noopener\">Nitrobenzene<\/a><\/td><td class=\"oth\">7.62<\/td><td class=\"oth\">10<\/td><td class=\"oth\">123<\/td><td class=\"oth\">77<\/td><td class=\"oth\">10<\/td><td class=\"oth\">123<\/td><td class=\"oth\">51<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">36.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosopiperidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-75-4\/N-Nitrosopiperidine\" target=\"_blank\" rel=\"noopener\">N-Nitrosopiperidine<\/a><\/td><td class=\"oth\">7.88<\/td><td class=\"oth\">10<\/td><td class=\"oth\">114<\/td><td class=\"oth\">84<\/td><td class=\"oth\">6<\/td><td class=\"oth\">114<\/td><td class=\"oth\">97<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">37.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isophorone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78-59-1\/Isophorone\" target=\"_blank\" rel=\"noopener\">Isophorone<\/a><\/td><td class=\"oth\">8.05<\/td><td class=\"oth\">10<\/td><td class=\"oth\">138<\/td><td class=\"oth\">82<\/td><td class=\"oth\">8<\/td><td class=\"oth\">82<\/td><td class=\"oth\">54<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">38.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Nitrophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88-75-5\/2-Nitrophenol\" target=\"_blank\" rel=\"noopener\">2-Nitrophenol<\/a><\/td><td class=\"oth\">8.19<\/td><td class=\"oth\">10<\/td><td class=\"oth\">139<\/td><td class=\"oth\">109<\/td><td class=\"oth\">8<\/td><td class=\"oth\">139<\/td><td class=\"oth\">81<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">39.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzoic acid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/65-85-0\/Benzoic acid\" target=\"_blank\" rel=\"noopener\">Benzoic acid<\/a><\/td><td class=\"oth\">8.31<\/td><td class=\"oth\">10<\/td><td class=\"oth\">122<\/td><td class=\"oth\">77<\/td><td class=\"oth\">20<\/td><td class=\"oth\">105<\/td><td class=\"oth\">77<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">40.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dimethylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/105-67-9\/2,4-Dimethylphenol\" target=\"_blank\" rel=\"noopener\">2,4-Dimethylphenol<\/a><\/td><td class=\"oth\">8.32<\/td><td class=\"oth\">10<\/td><td class=\"oth\">122<\/td><td class=\"oth\">107<\/td><td class=\"oth\">12<\/td><td class=\"oth\">122<\/td><td class=\"oth\">77<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">41.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for O,O,O-Triethyl phosphorothioate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/126-68-1\/O,O,O-Triethyl phosphorothioate\" target=\"_blank\" rel=\"noopener\">O,O,O-Triethyl phosphorothioate<\/a><\/td><td class=\"oth\">8.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">121<\/td><td class=\"oth\">65<\/td><td class=\"oth\">10<\/td><td class=\"oth\">198<\/td><td class=\"oth\">114<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">42.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bis(2-chloroethoxy)methane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111-91-1\/Bis(2-chloroethoxy)methane\" target=\"_blank\" rel=\"noopener\">Bis(2-chloroethoxy)methane<\/a><\/td><td class=\"oth\">8.5<\/td><td class=\"oth\">10<\/td><td class=\"oth\">63<\/td><td class=\"oth\">27<\/td><td class=\"oth\">12<\/td><td class=\"oth\">93<\/td><td class=\"oth\">63<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">43.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dichlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-83-2\/2,4-Dichlorophenol\" target=\"_blank\" rel=\"noopener\">2,4-Dichlorophenol<\/a><\/td><td class=\"oth\">8.64<\/td><td class=\"oth\">10<\/td><td class=\"oth\">98<\/td><td class=\"oth\">63<\/td><td class=\"oth\">8<\/td><td class=\"oth\">162<\/td><td class=\"oth\">98<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">44.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phentermine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/122-09-8\/Phentermine\" target=\"_blank\" rel=\"noopener\">Phentermine<\/a><\/td><td class=\"oth\">8.78<\/td><td class=\"oth\">10<\/td><td class=\"oth\">58<\/td><td class=\"oth\">42<\/td><td class=\"oth\">22<\/td><td class=\"oth\">134<\/td><td class=\"oth\">91<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">45.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,2,4-Trichlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-82-1\/1,2,4-Trichlorobenzene\" target=\"_blank\" rel=\"noopener\">1,2,4-Trichlorobenzene<\/a><\/td><td class=\"oth\">8.8<\/td><td class=\"oth\">10<\/td><td class=\"oth\">180<\/td><td class=\"oth\">145<\/td><td class=\"oth\">12<\/td><td class=\"oth\">180<\/td><td class=\"oth\">109<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">46.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Naphthalene-d8\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1146-65-2\/Naphthalene-d8\" target=\"_blank\" rel=\"noopener\">Naphthalene-d8<\/a><\/td><td class=\"oth\">8.89<\/td><td class=\"oth\">10<\/td><td class=\"oth\">136<\/td><td class=\"oth\">134<\/td><td class=\"oth\">14<\/td><td class=\"oth\">136<\/td><td class=\"oth\">84<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">47.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Naphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-20-3\/Naphthalene\" target=\"_blank\" rel=\"noopener\">Naphthalene<\/a><\/td><td class=\"oth\">8.92<\/td><td class=\"oth\">10<\/td><td class=\"oth\">128<\/td><td class=\"oth\">102<\/td><td class=\"oth\">16<\/td><td class=\"oth\">129<\/td><td class=\"oth\">103<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">48.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-Terpineol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/98-55-5\/\u03b1-Terpineol\" target=\"_blank\" rel=\"noopener\">\u03b1-Terpineol<\/a><\/td><td class=\"oth\">9<\/td><td class=\"oth\">10<\/td><td class=\"oth\">136<\/td><td class=\"oth\">121<\/td><td class=\"oth\">8<\/td><td class=\"oth\">136<\/td><td class=\"oth\">93<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">49.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Chloroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-47-8\/4-Chloroaniline\" target=\"_blank\" rel=\"noopener\">4-Chloroaniline<\/a><\/td><td class=\"oth\">9.06<\/td><td class=\"oth\">10<\/td><td class=\"oth\">127<\/td><td class=\"oth\">100<\/td><td class=\"oth\">10<\/td><td class=\"oth\">127<\/td><td class=\"oth\">65<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">50.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,6-Dichlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/87-65-0\/2,6-Dichlorophenol\" target=\"_blank\" rel=\"noopener\">2,6-Dichlorophenol<\/a><\/td><td class=\"oth\">9.07<\/td><td class=\"oth\">10<\/td><td class=\"oth\">162<\/td><td class=\"oth\">126<\/td><td class=\"oth\">8<\/td><td class=\"oth\">164<\/td><td class=\"oth\">63<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">51.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachloropropene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1888-71-7\/Hexachloropropene\" target=\"_blank\" rel=\"noopener\">Hexachloropropene<\/a><\/td><td class=\"oth\">9.12<\/td><td class=\"oth\">10<\/td><td class=\"oth\">213<\/td><td class=\"oth\">119<\/td><td class=\"oth\">18<\/td><td class=\"oth\">215<\/td><td class=\"oth\">119<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">52.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachlorobutadiene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/87-68-3\/Hexachlorobutadiene\" target=\"_blank\" rel=\"noopener\">Hexachlorobutadiene<\/a><\/td><td class=\"oth\">9.21<\/td><td class=\"oth\">10<\/td><td class=\"oth\">225<\/td><td class=\"oth\">190<\/td><td class=\"oth\">14<\/td><td class=\"oth\">260<\/td><td class=\"oth\">190<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">53.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Quinoline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-22-5\/Quinoline\" target=\"_blank\" rel=\"noopener\">Quinoline<\/a><\/td><td class=\"oth\">9.56<\/td><td class=\"oth\">10<\/td><td class=\"oth\">129<\/td><td class=\"oth\">102<\/td><td class=\"oth\">16<\/td><td class=\"oth\">129<\/td><td class=\"oth\">76<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">54.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Caprolactam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/105-60-2\/Caprolactam\" target=\"_blank\" rel=\"noopener\">Caprolactam<\/a><\/td><td class=\"oth\">9.65<\/td><td class=\"oth\">10<\/td><td class=\"oth\">113<\/td><td class=\"oth\">85<\/td><td class=\"oth\">6<\/td><td class=\"oth\">113<\/td><td class=\"oth\">56<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">55.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Phenylenediamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-50-3\/1,4-Phenylenediamine\" target=\"_blank\" rel=\"noopener\">1,4-Phenylenediamine<\/a><\/td><td class=\"oth\">9.73<\/td><td class=\"oth\">10<\/td><td class=\"oth\">108<\/td><td class=\"oth\">81<\/td><td class=\"oth\">10<\/td><td class=\"oth\">108<\/td><td class=\"oth\">80<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">56.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosodibutylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/924-16-3\/N-Nitrosodibutylamine\" target=\"_blank\" rel=\"noopener\">N-Nitrosodibutylamine<\/a><\/td><td class=\"oth\">9.76<\/td><td class=\"oth\">10<\/td><td class=\"oth\">116<\/td><td class=\"oth\">99<\/td><td class=\"oth\">6<\/td><td class=\"oth\">116<\/td><td class=\"oth\">74<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">57.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Chloro-3-methylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59-50-7\/4-Chloro-3-methylphenol\" target=\"_blank\" rel=\"noopener\">4-Chloro-3-methylphenol<\/a><\/td><td class=\"oth\">10.05<\/td><td class=\"oth\">10<\/td><td class=\"oth\">142<\/td><td class=\"oth\">107<\/td><td class=\"oth\">12<\/td><td class=\"oth\">142<\/td><td class=\"oth\">77<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">58.<\/td><td class=\"cmpd\">Isosafrole I<\/td><td class=\"oth\">10.14<\/td><td class=\"oth\">10<\/td><td class=\"oth\">131<\/td><td class=\"oth\">103<\/td><td class=\"oth\">8<\/td><td class=\"oth\">162<\/td><td class=\"oth\">104<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">59.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Methylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-57-6\/2-Methylnaphthalene\" target=\"_blank\" rel=\"noopener\">2-Methylnaphthalene<\/a><\/td><td class=\"oth\">10.27<\/td><td class=\"oth\">10<\/td><td class=\"oth\">141<\/td><td class=\"oth\">115<\/td><td class=\"oth\">16<\/td><td class=\"oth\">141<\/td><td class=\"oth\">89<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">60.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Methylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90-12-0\/1-Methylnaphthalene\" target=\"_blank\" rel=\"noopener\">1-Methylnaphthalene<\/a><\/td><td class=\"oth\">10.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">141<\/td><td class=\"oth\">115<\/td><td class=\"oth\">16<\/td><td class=\"oth\">141<\/td><td class=\"oth\">89<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">61.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,2,4,5-Tetrachlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-94-3\/1,2,4,5-Tetrachlorobenzene\" target=\"_blank\" rel=\"noopener\">1,2,4,5-Tetrachlorobenzene<\/a><\/td><td class=\"oth\">10.61<\/td><td class=\"oth\">10<\/td><td class=\"oth\">216<\/td><td class=\"oth\">181<\/td><td class=\"oth\">14<\/td><td class=\"oth\">216<\/td><td class=\"oth\">108<\/td><td class=\"oth\">36<\/td><\/tr>\n<tr><td class=\"num\">62.<\/td><td class=\"cmpd\">Hexachloropentadiene<\/td><td class=\"oth\">10.62<\/td><td class=\"oth\">10<\/td><td class=\"oth\">272<\/td><td class=\"oth\">237<\/td><td class=\"oth\">12<\/td><td class=\"oth\">237<\/td><td class=\"oth\">143<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">63.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,3-Dichloroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/608-27-5\/2,3-Dichloroaniline\" target=\"_blank\" rel=\"noopener\">2,3-Dichloroaniline<\/a><\/td><td class=\"oth\">10.83<\/td><td class=\"oth\">10<\/td><td class=\"oth\">161<\/td><td class=\"oth\">90<\/td><td class=\"oth\">16<\/td><td class=\"oth\">163<\/td><td class=\"oth\">90<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">64.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4,6-Trichlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88-06-2\/2,4,6-Trichlorophenol\" target=\"_blank\" rel=\"noopener\">2,4,6-Trichlorophenol<\/a><\/td><td class=\"oth\">10.85<\/td><td class=\"oth\">10<\/td><td class=\"oth\">132<\/td><td class=\"oth\">97<\/td><td class=\"oth\">10<\/td><td class=\"oth\">196<\/td><td class=\"oth\">97<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">65.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4,5-Trichlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-95-4\/2,4,5-Trichlorophenol\" target=\"_blank\" rel=\"noopener\">2,4,5-Trichlorophenol<\/a><\/td><td class=\"oth\">10.95<\/td><td class=\"oth\">10<\/td><td class=\"oth\">132<\/td><td class=\"oth\">97<\/td><td class=\"oth\">10<\/td><td class=\"oth\">196<\/td><td class=\"oth\">97<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">66.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Fluorobiphenyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/321-60-8\/2-Fluorobiphenyl\" target=\"_blank\" rel=\"noopener\">2-Fluorobiphenyl<\/a><\/td><td class=\"oth\">11.03<\/td><td class=\"oth\">10<\/td><td class=\"oth\">172<\/td><td class=\"oth\">171<\/td><td class=\"oth\">12<\/td><td class=\"oth\">172<\/td><td class=\"oth\">170<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">67.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Chloronaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-58-7\/2-Chloronaphthalene\" target=\"_blank\" rel=\"noopener\">2-Chloronaphthalene<\/a><\/td><td class=\"oth\">11.15<\/td><td class=\"oth\">10<\/td><td class=\"oth\">162<\/td><td class=\"oth\">127<\/td><td class=\"oth\">16<\/td><td class=\"oth\">162<\/td><td class=\"oth\">77<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">68.<\/td><td class=\"cmpd\">Isosafrole II<\/td><td class=\"oth\">11.17<\/td><td class=\"oth\">10<\/td><td class=\"oth\">131<\/td><td class=\"oth\">103<\/td><td class=\"oth\">10<\/td><td class=\"oth\">162<\/td><td class=\"oth\">104<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">69.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Safrole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/94-59-7\/Safrole\" target=\"_blank\" rel=\"noopener\">Safrole<\/a><\/td><td class=\"oth\">11.2<\/td><td class=\"oth\">10<\/td><td class=\"oth\">162<\/td><td class=\"oth\">127<\/td><td class=\"oth\">16<\/td><td class=\"oth\">131<\/td><td class=\"oth\">103<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">70.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Biphenyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92-52-4\/Biphenyl\" target=\"_blank\" rel=\"noopener\">Biphenyl<\/a><\/td><td class=\"oth\">11.21<\/td><td class=\"oth\">10<\/td><td class=\"oth\">154<\/td><td class=\"oth\">152<\/td><td class=\"oth\">22<\/td><td class=\"oth\">153<\/td><td class=\"oth\">126<\/td><td class=\"oth\">32<\/td><\/tr>\n<tr><td class=\"num\">71.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Chloronaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90-13-1\/1-Chloronaphthalene\" target=\"_blank\" rel=\"noopener\">1-Chloronaphthalene<\/a><\/td><td class=\"oth\">11.25<\/td><td class=\"oth\">10<\/td><td class=\"oth\">162<\/td><td class=\"oth\">127<\/td><td class=\"oth\">16<\/td><td class=\"oth\">127<\/td><td class=\"oth\">77<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">72.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for o-Nitroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88-74-4\/o-Nitroaniline\" target=\"_blank\" rel=\"noopener\">o-Nitroaniline<\/a><\/td><td class=\"oth\">11.43<\/td><td class=\"oth\">10<\/td><td class=\"oth\">138<\/td><td class=\"oth\">92<\/td><td class=\"oth\">12<\/td><td class=\"oth\">138<\/td><td class=\"oth\">65<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">73.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diphenyl ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/101-84-8\/Diphenyl ether\" target=\"_blank\" rel=\"noopener\">Diphenyl ether<\/a><\/td><td class=\"oth\">11.43<\/td><td class=\"oth\">10<\/td><td class=\"oth\">170<\/td><td class=\"oth\">142<\/td><td class=\"oth\">10<\/td><td class=\"oth\">141<\/td><td class=\"oth\">115<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">74.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Naphthoquinone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/130-15-4\/1,4-Naphthoquinone\" target=\"_blank\" rel=\"noopener\">1,4-Naphthoquinone<\/a><\/td><td class=\"oth\">11.57<\/td><td class=\"oth\">10<\/td><td class=\"oth\">158<\/td><td class=\"oth\">130<\/td><td class=\"oth\">8<\/td><td class=\"oth\">158<\/td><td class=\"oth\">102<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">75.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,2-Dinitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/528-29-0\/1,2-Dinitrobenzene\" target=\"_blank\" rel=\"noopener\">1,2-Dinitrobenzene<\/a><\/td><td class=\"oth\">11.86<\/td><td class=\"oth\">10<\/td><td class=\"oth\">122<\/td><td class=\"oth\">75<\/td><td class=\"oth\">12<\/td><td class=\"oth\">168<\/td><td class=\"oth\">75<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">76.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,3-Dinitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-65-0\/1,3-Dinitrobenzene\" target=\"_blank\" rel=\"noopener\">1,3-Dinitrobenzene<\/a><\/td><td class=\"oth\">11.87<\/td><td class=\"oth\">10<\/td><td class=\"oth\">168<\/td><td class=\"oth\">75<\/td><td class=\"oth\">20<\/td><td class=\"oth\">76<\/td><td class=\"oth\">50<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">77.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diphenyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/84-62-8\/Diphenyl phthalate\" target=\"_blank\" rel=\"noopener\">Diphenyl phthalate<\/a><\/td><td class=\"oth\">11.87<\/td><td class=\"oth\">10<\/td><td class=\"oth\">163<\/td><td class=\"oth\">133<\/td><td class=\"oth\">8<\/td><td class=\"oth\">163<\/td><td class=\"oth\">77<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">78.<\/td><td class=\"cmpd\">1,6-Dinitrotoluene<\/td><td class=\"oth\">11.95<\/td><td class=\"oth\">10<\/td><td class=\"oth\">165<\/td><td class=\"oth\">148<\/td><td class=\"oth\">8<\/td><td class=\"oth\">165<\/td><td class=\"oth\">63<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">79.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Dinitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-25-4\/1,4-Dinitrobenzene\" target=\"_blank\" rel=\"noopener\">1,4-Dinitrobenzene<\/a><\/td><td class=\"oth\">12.01<\/td><td class=\"oth\">10<\/td><td class=\"oth\">168<\/td><td class=\"oth\">51<\/td><td class=\"oth\">14<\/td><td class=\"oth\">76<\/td><td class=\"oth\">63<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">80.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/208-96-8\/Acenaphthylene\" target=\"_blank\" rel=\"noopener\">Acenaphthylene<\/a><\/td><td class=\"oth\">12.02<\/td><td class=\"oth\">10<\/td><td class=\"oth\">152<\/td><td class=\"oth\">126<\/td><td class=\"oth\">24<\/td><td class=\"oth\">152<\/td><td class=\"oth\">76<\/td><td class=\"oth\">36<\/td><\/tr>\n<tr><td class=\"num\">81.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3-Nitroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-09-2\/3-Nitroaniline\" target=\"_blank\" rel=\"noopener\">3-Nitroaniline<\/a><\/td><td class=\"oth\">12.25<\/td><td class=\"oth\">10<\/td><td class=\"oth\">92<\/td><td class=\"oth\">65<\/td><td class=\"oth\">8<\/td><td class=\"oth\">138<\/td><td class=\"oth\">65<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">82.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthene-d10\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/15067-26-2\/Acenaphthene-d10\" target=\"_blank\" rel=\"noopener\">Acenaphthene-d10<\/a><\/td><td class=\"oth\">12.32<\/td><td class=\"oth\">10<\/td><td class=\"oth\">164<\/td><td class=\"oth\">162<\/td><td class=\"oth\">14<\/td><td class=\"oth\">164<\/td><td class=\"oth\">160<\/td><td class=\"oth\">32<\/td><\/tr>\n<tr><td class=\"num\">83.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/83-32-9\/Acenaphthene\" target=\"_blank\" rel=\"noopener\">Acenaphthene<\/a><\/td><td class=\"oth\">12.37<\/td><td class=\"oth\">10<\/td><td class=\"oth\">153<\/td><td class=\"oth\">126<\/td><td class=\"oth\">36<\/td><td class=\"oth\">153<\/td><td class=\"oth\">77<\/td><td class=\"oth\">38<\/td><\/tr>\n<tr><td class=\"num\">84.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dinitrophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51-28-5\/2,4-Dinitrophenol\" target=\"_blank\" rel=\"noopener\">2,4-Dinitrophenol<\/a><\/td><td class=\"oth\">12.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">184<\/td><td class=\"oth\">154<\/td><td class=\"oth\">6<\/td><td class=\"oth\">184<\/td><td class=\"oth\">107<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">85.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Nitrophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-02-7\/4-Nitrophenol\" target=\"_blank\" rel=\"noopener\">4-Nitrophenol<\/a><\/td><td class=\"oth\">12.65<\/td><td class=\"oth\">10<\/td><td class=\"oth\">139<\/td><td class=\"oth\">109<\/td><td class=\"oth\">6<\/td><td class=\"oth\">139<\/td><td class=\"oth\">81<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">86.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/608-93-5\/Pentachlorobenzene\" target=\"_blank\" rel=\"noopener\">Pentachlorobenzene<\/a><\/td><td class=\"oth\">12.66<\/td><td class=\"oth\">10<\/td><td class=\"oth\">250<\/td><td class=\"oth\">215<\/td><td class=\"oth\">16<\/td><td class=\"oth\">250<\/td><td class=\"oth\">142<\/td><td class=\"oth\">38<\/td><\/tr>\n<tr><td class=\"num\">87.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenzofuran\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/132-64-9\/Dibenzofuran\" target=\"_blank\" rel=\"noopener\">Dibenzofuran<\/a><\/td><td class=\"oth\">12.73<\/td><td class=\"oth\">10<\/td><td class=\"oth\">168<\/td><td class=\"oth\">139<\/td><td class=\"oth\">22<\/td><td class=\"oth\">139<\/td><td class=\"oth\">63<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">88.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dinitrotoluene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/121-14-2\/2,4-Dinitrotoluene\" target=\"_blank\" rel=\"noopener\">2,4-Dinitrotoluene<\/a><\/td><td class=\"oth\">12.74<\/td><td class=\"oth\">10<\/td><td class=\"oth\">165<\/td><td class=\"oth\">119<\/td><td class=\"oth\">6<\/td><td class=\"oth\">165<\/td><td class=\"oth\">63<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">89.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Naphthylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/134-32-7\/1-Naphthylamine\" target=\"_blank\" rel=\"noopener\">1-Naphthylamine<\/a><\/td><td class=\"oth\">12.88<\/td><td class=\"oth\">10<\/td><td class=\"oth\">143<\/td><td class=\"oth\">116<\/td><td class=\"oth\">10<\/td><td class=\"oth\">143<\/td><td class=\"oth\">115<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">90.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,3,5,6-Tetrachlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/935-95-5\/2,3,5,6-Tetrachlorophenol\" target=\"_blank\" rel=\"noopener\">2,3,5,6-Tetrachlorophenol<\/a><\/td><td class=\"oth\">12.91<\/td><td class=\"oth\">10<\/td><td class=\"oth\">232<\/td><td class=\"oth\">168<\/td><td class=\"oth\">12<\/td><td class=\"oth\">234<\/td><td class=\"oth\">133<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">91.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,3,4,6-Tetrachlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/58-90-2\/2,3,4,6-Tetrachlorophenol\" target=\"_blank\" rel=\"noopener\">2,3,4,6-Tetrachlorophenol<\/a><\/td><td class=\"oth\">13<\/td><td class=\"oth\">10<\/td><td class=\"oth\">232<\/td><td class=\"oth\">168<\/td><td class=\"oth\">12<\/td><td class=\"oth\">234<\/td><td class=\"oth\">131<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">92.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Naphthylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-59-8\/2-Naphthylamine\" target=\"_blank\" rel=\"noopener\">2-Naphthylamine<\/a><\/td><td class=\"oth\">13.03<\/td><td class=\"oth\">10<\/td><td class=\"oth\">143<\/td><td class=\"oth\">116<\/td><td class=\"oth\">10<\/td><td class=\"oth\">143<\/td><td class=\"oth\">115<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">93.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diethyl Phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/84-66-2\/Diethyl Phthalate\" target=\"_blank\" rel=\"noopener\">Diethyl Phthalate<\/a><\/td><td class=\"oth\">13.3<\/td><td class=\"oth\">10<\/td><td class=\"oth\">177<\/td><td class=\"oth\">149<\/td><td class=\"oth\">8<\/td><td class=\"oth\">149<\/td><td class=\"oth\">65<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">94.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexadecane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/544-76-3\/Hexadecane\" target=\"_blank\" rel=\"noopener\">Hexadecane<\/a><\/td><td class=\"oth\">13.41<\/td><td class=\"oth\">10<\/td><td class=\"oth\">85<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><td class=\"oth\">99<\/td><td class=\"oth\">41<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">95.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluorene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/86-73-7\/Fluorene\" target=\"_blank\" rel=\"noopener\">Fluorene<\/a><\/td><td class=\"oth\">13.41<\/td><td class=\"oth\">10<\/td><td class=\"oth\">165<\/td><td class=\"oth\">139<\/td><td class=\"oth\">26<\/td><td class=\"oth\">167<\/td><td class=\"oth\">166<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">96.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Zinophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/297-97-2\/Zinophos\" target=\"_blank\" rel=\"noopener\">Zinophos<\/a><\/td><td class=\"oth\">13.45<\/td><td class=\"oth\">10<\/td><td class=\"oth\">143<\/td><td class=\"oth\">79<\/td><td class=\"oth\">10<\/td><td class=\"oth\">107<\/td><td class=\"oth\">52<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">97.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 5-Nitro-o-toluidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-55-8\/5-Nitro-o-toluidine\" target=\"_blank\" rel=\"noopener\">5-Nitro-o-toluidine<\/a><\/td><td class=\"oth\">13.45<\/td><td class=\"oth\">10<\/td><td class=\"oth\">152<\/td><td class=\"oth\">106<\/td><td class=\"oth\">10<\/td><td class=\"oth\">152<\/td><td class=\"oth\">77<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">98.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Nitroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-01-6\/4-Nitroaniline\" target=\"_blank\" rel=\"noopener\">4-Nitroaniline<\/a><\/td><td class=\"oth\">13.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">138<\/td><td class=\"oth\">108<\/td><td class=\"oth\">8<\/td><td class=\"oth\">138<\/td><td class=\"oth\">80<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">99.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Chlorophenyl phenyl ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7005-72-3\/4-Chlorophenyl phenyl ether\" target=\"_blank\" rel=\"noopener\">4-Chlorophenyl phenyl ether<\/a><\/td><td class=\"oth\">13.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">204<\/td><td class=\"oth\">77<\/td><td class=\"oth\">22<\/td><td class=\"oth\">141<\/td><td class=\"oth\">115<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">100.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4,6-Dinitro-2-methylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/534-52-1\/4,6-Dinitro-2-methylphenol\" target=\"_blank\" rel=\"noopener\">4,6-Dinitro-2-methylphenol<\/a><\/td><td class=\"oth\">13.54<\/td><td class=\"oth\">10<\/td><td class=\"oth\">198<\/td><td class=\"oth\">168<\/td><td class=\"oth\">6<\/td><td class=\"oth\">198<\/td><td class=\"oth\">121<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">101.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diphenylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/122-39-4\/Diphenylamine\" target=\"_blank\" rel=\"noopener\">Diphenylamine<\/a><\/td><td class=\"oth\">13.7<\/td><td class=\"oth\">10<\/td><td class=\"oth\">169<\/td><td class=\"oth\">66<\/td><td class=\"oth\">22<\/td><td class=\"oth\">169<\/td><td class=\"oth\">77<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">102.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Azobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/103-33-3\/Azobenzene\" target=\"_blank\" rel=\"noopener\">Azobenzene<\/a><\/td><td class=\"oth\">13.76<\/td><td class=\"oth\">10<\/td><td class=\"oth\">182<\/td><td class=\"oth\">105<\/td><td class=\"oth\">6<\/td><td class=\"oth\">182<\/td><td class=\"oth\">77<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">103.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4,6-Tribromophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/118-79-6\/2,4,6-Tribromophenol\" target=\"_blank\" rel=\"noopener\">2,4,6-Tribromophenol<\/a><\/td><td class=\"oth\">13.88<\/td><td class=\"oth\">10<\/td><td class=\"oth\">330<\/td><td class=\"oth\">222<\/td><td class=\"oth\">20<\/td><td class=\"oth\">332<\/td><td class=\"oth\">143<\/td><td class=\"oth\">34<\/td><\/tr>\n<tr><td class=\"num\">104.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Sulfotepp\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3689-24-5\/Sulfotepp\" target=\"_blank\" rel=\"noopener\">Sulfotepp<\/a><\/td><td class=\"oth\">14.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">202<\/td><td class=\"oth\">146<\/td><td class=\"oth\">10<\/td><td class=\"oth\">322<\/td><td class=\"oth\">146<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">105.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,3,5-Trinitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-35-4\/1,3,5-Trinitrobenzene\" target=\"_blank\" rel=\"noopener\">1,3,5-Trinitrobenzene<\/a><\/td><td class=\"oth\">14.23<\/td><td class=\"oth\">10<\/td><td class=\"oth\">213<\/td><td class=\"oth\">167<\/td><td class=\"oth\">8<\/td><td class=\"oth\">213<\/td><td class=\"oth\">74<\/td><td class=\"oth\">38<\/td><\/tr>\n<tr><td class=\"num\">106.<\/td><td class=\"cmpd\">Diallate 1<\/td><td class=\"oth\">14.31<\/td><td class=\"oth\">10<\/td><td class=\"oth\">86<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><td class=\"oth\">234<\/td><td class=\"oth\">150<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">107.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phorate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-02-2\/Phorate\" target=\"_blank\" rel=\"noopener\">Phorate<\/a><\/td><td class=\"oth\">14.32<\/td><td class=\"oth\">10<\/td><td class=\"oth\">75<\/td><td class=\"oth\">47<\/td><td class=\"oth\">8<\/td><td class=\"oth\">121<\/td><td class=\"oth\">47<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">108.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenacetin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62-44-2\/Phenacetin\" target=\"_blank\" rel=\"noopener\">Phenacetin<\/a><\/td><td class=\"oth\">14.35<\/td><td class=\"oth\">10<\/td><td class=\"oth\">179<\/td><td class=\"oth\">137<\/td><td class=\"oth\">8<\/td><td class=\"oth\">179<\/td><td class=\"oth\">109<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">109.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Bromophenyl phenyl ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/101-55-3\/4-Bromophenyl phenyl ether\" target=\"_blank\" rel=\"noopener\">4-Bromophenyl phenyl ether<\/a><\/td><td class=\"oth\">14.41<\/td><td class=\"oth\">10<\/td><td class=\"oth\">248<\/td><td class=\"oth\">141<\/td><td class=\"oth\">14<\/td><td class=\"oth\">141<\/td><td class=\"oth\">115<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">110.<\/td><td class=\"cmpd\">Diallate 2<\/td><td class=\"oth\">14.48<\/td><td class=\"oth\">10<\/td><td class=\"oth\">234<\/td><td class=\"oth\">150<\/td><td class=\"oth\">16<\/td><td class=\"oth\">86<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">111.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/118-74-1\/Hexachlorobenzene\" target=\"_blank\" rel=\"noopener\">Hexachlorobenzene<\/a><\/td><td class=\"oth\">14.5<\/td><td class=\"oth\">10<\/td><td class=\"oth\">284<\/td><td class=\"oth\">249<\/td><td class=\"oth\">14<\/td><td class=\"oth\">288<\/td><td class=\"oth\">216<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">112.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dimethoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60-51-5\/Dimethoate\" target=\"_blank\" rel=\"noopener\">Dimethoate<\/a><\/td><td class=\"oth\">14.6<\/td><td class=\"oth\">10<\/td><td class=\"oth\">93<\/td><td class=\"oth\">63<\/td><td class=\"oth\">8<\/td><td class=\"oth\">125<\/td><td class=\"oth\">47<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">113.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Atrazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1912-24-9\/Atrazine\" target=\"_blank\" rel=\"noopener\">Atrazine<\/a><\/td><td class=\"oth\">14.82<\/td><td class=\"oth\">10<\/td><td class=\"oth\">200<\/td><td class=\"oth\">122<\/td><td class=\"oth\">8<\/td><td class=\"oth\">215<\/td><td class=\"oth\">200<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">114.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/87-86-5\/Pentachlorophenol\" target=\"_blank\" rel=\"noopener\">Pentachlorophenol<\/a><\/td><td class=\"oth\">14.9<\/td><td class=\"oth\">10<\/td><td class=\"oth\">266<\/td><td class=\"oth\">167<\/td><td class=\"oth\">22<\/td><td class=\"oth\">270<\/td><td class=\"oth\">169<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">115.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Aminobiphenyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92-67-1\/4-Aminobiphenyl\" target=\"_blank\" rel=\"noopener\">4-Aminobiphenyl<\/a><\/td><td class=\"oth\">14.93<\/td><td class=\"oth\">10<\/td><td class=\"oth\">168<\/td><td class=\"oth\">141<\/td><td class=\"oth\">8<\/td><td class=\"oth\">168<\/td><td class=\"oth\">167<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">116.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachloronitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/82-68-8\/Pentachloronitrobenzene\" target=\"_blank\" rel=\"noopener\">Pentachloronitrobenzene<\/a><\/td><td class=\"oth\">14.93<\/td><td class=\"oth\">10<\/td><td class=\"oth\">295<\/td><td class=\"oth\">265<\/td><td class=\"oth\">8<\/td><td class=\"oth\">237<\/td><td class=\"oth\">143<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">117.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propyzamide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/23950-58-5\/Propyzamide\" target=\"_blank\" rel=\"noopener\">Propyzamide<\/a><\/td><td class=\"oth\">15.13<\/td><td class=\"oth\">10<\/td><td class=\"oth\">173<\/td><td class=\"oth\">145<\/td><td class=\"oth\">14<\/td><td class=\"oth\">254<\/td><td class=\"oth\">191<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">118.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenanthrene-d10\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1517-22-2\/Phenanthrene-d10\" target=\"_blank\" rel=\"noopener\">Phenanthrene-d10<\/a><\/td><td class=\"oth\">15.24<\/td><td class=\"oth\">10<\/td><td class=\"oth\">188<\/td><td class=\"oth\">160<\/td><td class=\"oth\">20<\/td><td class=\"oth\">184<\/td><td class=\"oth\">154<\/td><td class=\"oth\">32<\/td><\/tr>\n<tr><td class=\"num\">119.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Octadecane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/593-45-3\/Octadecane\" target=\"_blank\" rel=\"noopener\">Octadecane<\/a><\/td><td class=\"oth\">15.27<\/td><td class=\"oth\">10<\/td><td class=\"oth\">85<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><td class=\"oth\">99<\/td><td class=\"oth\">41<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">120.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenanthrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85-01-8\/Phenanthrene\" target=\"_blank\" rel=\"noopener\">Phenanthrene<\/a><\/td><td class=\"oth\">15.29<\/td><td class=\"oth\">10<\/td><td class=\"oth\">178<\/td><td class=\"oth\">152<\/td><td class=\"oth\">18<\/td><td class=\"oth\">178<\/td><td class=\"oth\">151<\/td><td class=\"oth\">32<\/td><\/tr>\n<tr><td class=\"num\">121.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dinoseb\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88-85-7\/Dinoseb\" target=\"_blank\" rel=\"noopener\">Dinoseb<\/a><\/td><td class=\"oth\">15.34<\/td><td class=\"oth\">10<\/td><td class=\"oth\">163<\/td><td class=\"oth\">116<\/td><td class=\"oth\">14<\/td><td class=\"oth\">240<\/td><td class=\"oth\">117<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">122.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Disulfoton\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-04-4\/Disulfoton\" target=\"_blank\" rel=\"noopener\">Disulfoton<\/a><\/td><td class=\"oth\">15.36<\/td><td class=\"oth\">10<\/td><td class=\"oth\">88<\/td><td class=\"oth\">60<\/td><td class=\"oth\">6<\/td><td class=\"oth\">97<\/td><td class=\"oth\">65<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">123.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-12-7\/Anthracene\" target=\"_blank\" rel=\"noopener\">Anthracene<\/a><\/td><td class=\"oth\">15.39<\/td><td class=\"oth\">10<\/td><td class=\"oth\">178<\/td><td class=\"oth\">152<\/td><td class=\"oth\">18<\/td><td class=\"oth\">178<\/td><td class=\"oth\">151<\/td><td class=\"oth\">32<\/td><\/tr>\n<tr><td class=\"num\">124.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carbazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/86-74-8\/Carbazole\" target=\"_blank\" rel=\"noopener\">Carbazole<\/a><\/td><td class=\"oth\">15.741<\/td><td class=\"oth\">10<\/td><td class=\"oth\">167<\/td><td class=\"oth\">166<\/td><td class=\"oth\">12<\/td><td class=\"oth\">167<\/td><td class=\"oth\">139<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">125.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl Parathion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-00-0\/Methyl Parathion\" target=\"_blank\" rel=\"noopener\">Methyl Parathion<\/a><\/td><td class=\"oth\">16.08<\/td><td class=\"oth\">10<\/td><td class=\"oth\">263<\/td><td class=\"oth\">109<\/td><td class=\"oth\">10<\/td><td class=\"oth\">263<\/td><td class=\"oth\">79<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">126.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for di-n-Butyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/84-74-2\/di-n-Butyl phthalate\" target=\"_blank\" rel=\"noopener\">di-n-Butyl phthalate<\/a><\/td><td class=\"oth\">16.58<\/td><td class=\"oth\">10<\/td><td class=\"oth\">149<\/td><td class=\"oth\">121<\/td><td class=\"oth\">12<\/td><td class=\"oth\">149<\/td><td class=\"oth\">65<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">127.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Nitroquinoline-N-oxide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-57-5\/4-Nitroquinoline-N-oxide\" target=\"_blank\" rel=\"noopener\">4-Nitroquinoline-N-oxide<\/a><\/td><td class=\"oth\">16.83<\/td><td class=\"oth\">10<\/td><td class=\"oth\">190<\/td><td class=\"oth\">160<\/td><td class=\"oth\">8<\/td><td class=\"oth\">101<\/td><td class=\"oth\">75<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">128.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethyl Parathion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-38-2\/Ethyl Parathion\" target=\"_blank\" rel=\"noopener\">Ethyl Parathion<\/a><\/td><td class=\"oth\">16.89<\/td><td class=\"oth\">10<\/td><td class=\"oth\">109<\/td><td class=\"oth\">81<\/td><td class=\"oth\">10<\/td><td class=\"oth\">291<\/td><td class=\"oth\">81<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">129.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methapyrilene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-80-5\/Methapyrilene\" target=\"_blank\" rel=\"noopener\">Methapyrilene<\/a><\/td><td class=\"oth\">17.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">97<\/td><td class=\"oth\">53<\/td><td class=\"oth\">16<\/td><td class=\"oth\">190<\/td><td class=\"oth\">97<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">130.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isodrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/465-73-6\/Isodrin\" target=\"_blank\" rel=\"noopener\">Isodrin<\/a><\/td><td class=\"oth\">17.36<\/td><td class=\"oth\">10<\/td><td class=\"oth\">261<\/td><td class=\"oth\">226<\/td><td class=\"oth\">16<\/td><td class=\"oth\">261<\/td><td class=\"oth\">191<\/td><td class=\"oth\">28<\/td><\/tr>\n<tr><td class=\"num\">131.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/206-44-0\/Fluoranthene\" target=\"_blank\" rel=\"noopener\">Fluoranthene<\/a><\/td><td class=\"oth\">17.65<\/td><td class=\"oth\">10<\/td><td class=\"oth\">202<\/td><td class=\"oth\">176<\/td><td class=\"oth\">26<\/td><td class=\"oth\">184<\/td><td class=\"oth\">156<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">132.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/206-44-0\/Fluoranthene\" target=\"_blank\" rel=\"noopener\">Fluoranthene<\/a><\/td><td class=\"oth\">17.65<\/td><td class=\"oth\">10<\/td><td class=\"oth\">202<\/td><td class=\"oth\">152<\/td><td class=\"oth\">30<\/td><td class=\"oth\">200<\/td><td class=\"oth\">174<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">133.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92-87-5\/Benzidine\" target=\"_blank\" rel=\"noopener\">Benzidine<\/a><\/td><td class=\"oth\">17.99<\/td><td class=\"oth\">10<\/td><td class=\"oth\">184<\/td><td class=\"oth\">166<\/td><td class=\"oth\">16<\/td><td class=\"oth\">200<\/td><td class=\"oth\">149<\/td><td class=\"oth\">34<\/td><\/tr>\n<tr><td class=\"num\">134.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/129-00-0\/Pyrene\" target=\"_blank\" rel=\"noopener\">Pyrene<\/a><\/td><td class=\"oth\">18.08<\/td><td class=\"oth\">10<\/td><td class=\"oth\">200<\/td><td class=\"oth\">150<\/td><td class=\"oth\">26<\/td><td class=\"oth\">212<\/td><td class=\"oth\">208<\/td><td class=\"oth\">36<\/td><\/tr>\n<tr><td class=\"num\">135.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for p-Terphenyl-d14\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1718-51-0\/p-Terphenyl-d14\" target=\"_blank\" rel=\"noopener\">p-Terphenyl-d14<\/a><\/td><td class=\"oth\">18.5<\/td><td class=\"oth\">10<\/td><td class=\"oth\">244<\/td><td class=\"oth\">242<\/td><td class=\"oth\">14<\/td><td class=\"oth\">244<\/td><td class=\"oth\">240<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">136.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aramite 1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/140-57-8\/Aramite 1\" target=\"_blank\" rel=\"noopener\">Aramite 1<\/a><\/td><td class=\"oth\">18.55<\/td><td class=\"oth\">10<\/td><td class=\"oth\">319<\/td><td class=\"oth\">185<\/td><td class=\"oth\">6<\/td><td class=\"oth\">175<\/td><td class=\"oth\">107<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">137.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aramite 2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/140-57-8\/Aramite 2\" target=\"_blank\" rel=\"noopener\">Aramite 2<\/a><\/td><td class=\"oth\">18.7<\/td><td class=\"oth\">10<\/td><td class=\"oth\">185<\/td><td class=\"oth\">63<\/td><td class=\"oth\">12<\/td><td class=\"oth\">319<\/td><td class=\"oth\">185<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">138.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for p-Dimethylaminoazobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60-11-7\/p-Dimethylaminoazobenzene\" target=\"_blank\" rel=\"noopener\">p-Dimethylaminoazobenzene<\/a><\/td><td class=\"oth\">18.79<\/td><td class=\"oth\">10<\/td><td class=\"oth\">225<\/td><td class=\"oth\">148<\/td><td class=\"oth\">6<\/td><td class=\"oth\">120<\/td><td class=\"oth\">77<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">139.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorobenzilate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/510-15-6\/Chlorobenzilate\" target=\"_blank\" rel=\"noopener\">Chlorobenzilate<\/a><\/td><td class=\"oth\">18.93<\/td><td class=\"oth\">10<\/td><td class=\"oth\">251<\/td><td class=\"oth\">139<\/td><td class=\"oth\">12<\/td><td class=\"oth\">251<\/td><td class=\"oth\">111<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">140.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Famphur\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52-85-7\/Famphur\" target=\"_blank\" rel=\"noopener\">Famphur<\/a><\/td><td class=\"oth\">19.4<\/td><td class=\"oth\">10<\/td><td class=\"oth\">218<\/td><td class=\"oth\">109<\/td><td class=\"oth\">14<\/td><td class=\"oth\">125<\/td><td class=\"oth\">79<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">141.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3,3&amp;apos;-Dimethylbenzidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/119-93-7\/3,3&amp;apos;-Dimethylbenzidine\" target=\"_blank\" rel=\"noopener\">3,3&#8242;-Dimethylbenzidine<\/a><\/td><td class=\"oth\">19.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">211<\/td><td class=\"oth\">196<\/td><td class=\"oth\">8<\/td><td class=\"oth\">211<\/td><td class=\"oth\">195<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">142.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Kepone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/143-50-0\/Kepone\" target=\"_blank\" rel=\"noopener\">Kepone<\/a><\/td><td class=\"oth\">19.47<\/td><td class=\"oth\">10<\/td><td class=\"oth\">272<\/td><td class=\"oth\">237<\/td><td class=\"oth\">12<\/td><td class=\"oth\">237<\/td><td class=\"oth\">143<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">143.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzyl butyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85-68-7\/Benzyl butyl phthalate\" target=\"_blank\" rel=\"noopener\">Benzyl butyl phthalate<\/a><\/td><td class=\"oth\">19.56<\/td><td class=\"oth\">10<\/td><td class=\"oth\">206<\/td><td class=\"oth\">149<\/td><td class=\"oth\">8<\/td><td class=\"oth\">149<\/td><td class=\"oth\">121<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">144.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bis(2-ethylhexyl) adipate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/103-23-1\/Bis(2-ethylhexyl) adipate\" target=\"_blank\" rel=\"noopener\">Bis(2-ethylhexyl) adipate<\/a><\/td><td class=\"oth\">19.81<\/td><td class=\"oth\">10<\/td><td class=\"oth\">129<\/td><td class=\"oth\">55<\/td><td class=\"oth\">14<\/td><td class=\"oth\">129<\/td><td class=\"oth\">83<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">145.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Acetylaminofluorene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53-96-3\/2-Acetylaminofluorene\" target=\"_blank\" rel=\"noopener\">2-Acetylaminofluorene<\/a><\/td><td class=\"oth\">19.93<\/td><td class=\"oth\">10<\/td><td class=\"oth\">223<\/td><td class=\"oth\">181<\/td><td class=\"oth\">10<\/td><td class=\"oth\">181<\/td><td class=\"oth\">152<\/td><td class=\"oth\">34<\/td><\/tr>\n<tr><td class=\"num\">146.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benz[a]anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-55-3\/Benz[a]anthracene\" target=\"_blank\" rel=\"noopener\">Benz[a]anthracene<\/a><\/td><td class=\"oth\">20.5<\/td><td class=\"oth\">10<\/td><td class=\"oth\">228<\/td><td class=\"oth\">202<\/td><td class=\"oth\">22<\/td><td class=\"oth\">226<\/td><td class=\"oth\">200<\/td><td class=\"oth\">28<\/td><\/tr>\n<tr><td class=\"num\">147.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chrysene-d12\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1719-03-5\/Chrysene-d12\" target=\"_blank\" rel=\"noopener\">Chrysene-d12<\/a><\/td><td class=\"oth\">20.51<\/td><td class=\"oth\">10<\/td><td class=\"oth\">240<\/td><td class=\"oth\">238<\/td><td class=\"oth\">14<\/td><td class=\"oth\">240<\/td><td class=\"oth\">236<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">148.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3,3&amp;apos;-Dichlorobenzidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-94-1\/3,3&amp;apos;-Dichlorobenzidine\" target=\"_blank\" rel=\"noopener\">3,3&#8242;-Dichlorobenzidine<\/a><\/td><td class=\"oth\">20.51<\/td><td class=\"oth\">10<\/td><td class=\"oth\">252<\/td><td class=\"oth\">181<\/td><td class=\"oth\">22<\/td><td class=\"oth\">252<\/td><td class=\"oth\">182<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">149.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4,4&amp;apos;-Methylenebis(2-chloroaniline)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/101-14-4\/4,4&amp;apos;-Methylenebis(2-chloroaniline)\" target=\"_blank\" rel=\"noopener\">4,4&#8242;-Methylenebis(2-chloroaniline)<\/a><\/td><td class=\"oth\">20.53<\/td><td class=\"oth\">10<\/td><td class=\"oth\">231<\/td><td class=\"oth\">195<\/td><td class=\"oth\">16<\/td><td class=\"oth\">266<\/td><td class=\"oth\">231<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">150.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chrysene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/218-01-9\/Chrysene\" target=\"_blank\" rel=\"noopener\">Chrysene<\/a><\/td><td class=\"oth\">20.56<\/td><td class=\"oth\">10<\/td><td class=\"oth\">228<\/td><td class=\"oth\">202<\/td><td class=\"oth\">22<\/td><td class=\"oth\">228<\/td><td class=\"oth\">201<\/td><td class=\"oth\">36<\/td><\/tr>\n<tr><td class=\"num\">151.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bis(2-ethylhexyl) phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/117-81-7\/Bis(2-ethylhexyl) phthalate\" target=\"_blank\" rel=\"noopener\">Bis(2-ethylhexyl) phthalate<\/a><\/td><td class=\"oth\">20.78<\/td><td class=\"oth\">10<\/td><td class=\"oth\">167<\/td><td class=\"oth\">149<\/td><td class=\"oth\">8<\/td><td class=\"oth\">149<\/td><td class=\"oth\">121<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">152.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 6-Methylchrysene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1705-85-7\/6-Methylchrysene\" target=\"_blank\" rel=\"noopener\">6-Methylchrysene<\/a><\/td><td class=\"oth\">21.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">242<\/td><td class=\"oth\">226<\/td><td class=\"oth\">28<\/td><td class=\"oth\">239<\/td><td class=\"oth\">213<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">153.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Di-n-octyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/117-84-0\/Di-n-octyl phthalate\" target=\"_blank\" rel=\"noopener\">Di-n-octyl phthalate<\/a><\/td><td class=\"oth\">22.08<\/td><td class=\"oth\">10<\/td><td class=\"oth\">149<\/td><td class=\"oth\">121<\/td><td class=\"oth\">12<\/td><td class=\"oth\">149<\/td><td class=\"oth\">93<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">154.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[b]fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/205-99-2\/Benzo[b]fluoranthene\" target=\"_blank\" rel=\"noopener\">Benzo[b]fluoranthene<\/a><\/td><td class=\"oth\">22.68<\/td><td class=\"oth\">10<\/td><td class=\"oth\">252<\/td><td class=\"oth\">226<\/td><td class=\"oth\">22<\/td><td class=\"oth\">250<\/td><td class=\"oth\">224<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">155.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 7,12-Dimethylbenz[a]anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57-97-6\/7,12-Dimethylbenz[a]anthracene\" target=\"_blank\" rel=\"noopener\">7,12-Dimethylbenz[a]anthracene<\/a><\/td><td class=\"oth\">22.69<\/td><td class=\"oth\">10<\/td><td class=\"oth\">256<\/td><td class=\"oth\">241<\/td><td class=\"oth\">12<\/td><td class=\"oth\">241<\/td><td class=\"oth\">226<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">156.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[k]fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/207-08-9\/Benzo[k]fluoranthene\" target=\"_blank\" rel=\"noopener\">Benzo[k]fluoranthene<\/a><\/td><td class=\"oth\">22.74<\/td><td class=\"oth\">10<\/td><td class=\"oth\">252<\/td><td class=\"oth\">226<\/td><td class=\"oth\">22<\/td><td class=\"oth\">250<\/td><td class=\"oth\">224<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">157.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[a]pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-32-8\/Benzo[a]pyrene\" target=\"_blank\" rel=\"noopener\">Benzo[a]pyrene<\/a><\/td><td class=\"oth\">23.41<\/td><td class=\"oth\">10<\/td><td class=\"oth\">252<\/td><td class=\"oth\">226<\/td><td class=\"oth\">22<\/td><td class=\"oth\">250<\/td><td class=\"oth\">224<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">158.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perylene-d12\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1520-96-3\/Perylene-d12\" target=\"_blank\" rel=\"noopener\">Perylene-d12<\/a><\/td><td class=\"oth\">23.55<\/td><td class=\"oth\">10<\/td><td class=\"oth\">264<\/td><td class=\"oth\">262<\/td><td class=\"oth\">20<\/td><td class=\"oth\">264<\/td><td class=\"oth\">260<\/td><td class=\"oth\">34<\/td><\/tr>\n<tr><td class=\"num\">159.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3-Methylcholanthrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-49-5\/3-Methylcholanthrene\" target=\"_blank\" rel=\"noopener\">3-Methylcholanthrene<\/a><\/td><td class=\"oth\">24.32<\/td><td class=\"oth\">10<\/td><td class=\"oth\">268<\/td><td class=\"oth\">253<\/td><td class=\"oth\">14<\/td><td class=\"oth\">252<\/td><td class=\"oth\">226<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">160.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenz(a,h)acridine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/226-36-8\/Dibenz(a,h)acridine\" target=\"_blank\" rel=\"noopener\">Dibenz(a,h)acridine<\/a><\/td><td class=\"oth\">25.8<\/td><td class=\"oth\">10<\/td><td class=\"oth\">279<\/td><td class=\"oth\">252<\/td><td class=\"oth\">34<\/td><td class=\"oth\">278<\/td><td class=\"oth\">250<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">161.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenz[a,j]acridine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/224-42-0\/Dibenz[a,j]acridine\" target=\"_blank\" rel=\"noopener\">Dibenz[a,j]acridine<\/a><\/td><td class=\"oth\">25.88<\/td><td class=\"oth\">10<\/td><td class=\"oth\">279<\/td><td class=\"oth\">277<\/td><td class=\"oth\">30<\/td><td class=\"oth\">278<\/td><td class=\"oth\">250<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">162.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Indeno[1,2,3-cd]pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/193-39-5\/Indeno[1,2,3-cd]pyrene\" target=\"_blank\" rel=\"noopener\">Indeno[1,2,3-cd]pyrene<\/a><\/td><td class=\"oth\">26.32<\/td><td class=\"oth\">10<\/td><td class=\"oth\">138<\/td><td class=\"oth\">125<\/td><td class=\"oth\">12<\/td><td class=\"oth\">276<\/td><td class=\"oth\">250<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">163.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenz[a,h]anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53-70-3\/Dibenz[a,h]anthracene\" target=\"_blank\" rel=\"noopener\">Dibenz[a,h]anthracene<\/a><\/td><td class=\"oth\">26.43<\/td><td class=\"oth\">10<\/td><td class=\"oth\">139<\/td><td class=\"oth\">126<\/td><td class=\"oth\">8<\/td><td class=\"oth\">139<\/td><td class=\"oth\">113<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">164.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[ghi]perylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/191-24-2\/Benzo[ghi]perylene\" target=\"_blank\" rel=\"noopener\">Benzo[ghi]perylene<\/a><\/td><td class=\"oth\">27.05<\/td><td class=\"oth\">10<\/td><td class=\"oth\">138<\/td><td class=\"oth\">125<\/td><td class=\"oth\">12<\/td><td class=\"oth\">138<\/td><td class=\"oth\">124<\/td><td class=\"oth\">28<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>RMX-5Sil MS, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/17323\" rel=\"noopener\">cat.# 17323<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>SVOC MegaMix 150 kit (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31907\" rel=\"noopener\">cat.# 31907<\/a>)<\/td><\/tr><tr><td><\/td><td>Revised SV internal standard mix (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31886\" rel=\"noopener\">cat.# 31886<\/a>)<\/td><\/tr><tr><td><\/td><td>Base neutral surrogate mix (4\/89 SOW) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31024\" rel=\"noopener\">cat.# 31024<\/a>)<\/td><\/tr><tr><td><\/td><td>Acid surrogate mix (4\/89 SOW) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31025\" rel=\"noopener\">cat.# 31025<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Dichloromethane<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>100 ppb <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 10:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 4.0 mm ID Precision liner w\/wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23267\" rel=\"noopener\">cat.# 23267<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Split Vent Flow Rate:<\/th><td>12 mL\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>40 &#176;C (hold 1 min) to 280 &#176;C at 12 &#176;C\/min to 310 &#176;C at 3 &#176;C\/min (hold 1 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.2 mL\/min @ 40 \u00b0C<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>SRM\/MRM<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>330 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Triple Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Collision Gas:<\/th><td>Ar <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>PFTBA <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Emission Current:<\/th><td>70 \u03bcA<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Thermo Scientific TSQ 8000 Triple Quadrupole GC-MS<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Standards were combined and diluted to a concentration of 100 ppb.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31907<\/li><li>31886<\/li><li>31024<\/li><li>31025<\/li><li>17323<\/li><li>23267<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>8270<\/li><li>8270e<\/li><li>RMX-library<\/li><li>environmental<\/li><li>semivolatile<\/li><li>semivolatiles-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1527.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2 :<\/strong> La grande inertie des colonnes RMX-5Sil MS aide \u00e0 respecter les exigences de qualit\u00e9 des donn\u00e9es pour une large gamme de compos\u00e9s semi-volatils difficiles \u00e0 des concentrations extr\u00eamement faibles.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1526.png\" alt=\"Select Semivolatiles at Low Levels on RMX-5Sil MS by GC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1526<\/p><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>RMX-5Sil MS, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/17323\" rel=\"noopener\">cat.# 17323<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>SVOC MegaMix 150 kit (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31907\" rel=\"noopener\">cat.# 31907<\/a>)<\/td><\/tr><tr><td><\/td><td>Revised SV internal standard mix (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31886\" rel=\"noopener\">cat.# 31886<\/a>)<\/td><\/tr><tr><td><\/td><td>Base neutral surrogate mix (4\/89 SOW) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31024\" rel=\"noopener\">cat.# 31024<\/a>)<\/td><\/tr><tr><td><\/td><td>Acid surrogate mix (4\/89 SOW) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31025\" rel=\"noopener\">cat.# 31025<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Dichloromethane<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>1, 10, 100 ppb <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 10:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 4.0 mm ID Precision liner w\/wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23267\" rel=\"noopener\">cat.# 23267<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Split Vent Flow Rate:<\/th><td>12 mL\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>40 &#176;C (hold 1 min) to 280 &#176;C at 12 &#176;C\/min to 310 &#176;C at 3 &#176;C\/min (hold 1 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.2 mL\/min @ 40 \u00b0C<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>SRM\/MRM<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>330 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Triple Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Collision Gas:<\/th><td>Ar <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>PFTBA <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Emission Current:<\/th><td>70 \u03bcA<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Thermo Scientific TSQ 8000 Triple Quadrupole GC-MS<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31907<\/li><li>31886<\/li><li>31024<\/li><li>31025<\/li><li>17323<\/li><li>23267<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>RMX-library<\/li><li>semivolatiles<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1526.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>R\u00e9f\u00e9rences<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>RMX GC columns brochure, GNBR4923-UNV, Restek Corporation, 2026. <a href=\"https:\/\/discover.restek.com\/articles\/gnbr4923\/rmx-gc-columns-unleash-your-performance\">https:\/\/discover.restek.com\/articles\/gnbr4923\/rmx-gc-columns-unleash-your-performance<\/a><\/li>\n\n\n\n<li>E. Pack, J. Hoisington, C. English, R. Dhandapani, and C. Myers, Comprehensive trace-level GC-MS\/MS semivolatiles method, Application note,&nbsp;EVAN4920-UNV, Restek Corporation, 2025. <a href=\"https:\/\/discover.restek.com\/fr\/notes-dapplication\/evan4920-fr\/methode-gc-ms-ms-complete-pour-l-analyse-des-composes-semi-volatils-a-l-etat-de-traces\">https:\/\/discover.restek.com\/en\/application-notes\/evan4920\/comprehensive-trace-level-gc-ms-ms-semivolatiles-method<\/a><\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full has-custom-border\"><a href=\"https:\/\/discover.restek.com\/fr\/articles-fr\/gnot3445-fr\/outils-en-ligne-ezgc\"><img loading=\"lazy\" decoding=\"async\" width=\"1340\" height=\"312\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block_FR.png\" alt=\"\" class=\"has-border-color wp-image-83966\" style=\"border-color:var(--global-palette9);border-top-left-radius:10px;border-top-right-radius:10px;border-bottom-left-radius:10px;border-bottom-right-radius:10px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block_FR.png 1340w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block_FR-300x70.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block_FR-1024x238.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block_FR-768x179.png 768w\" sizes=\"auto, (max-width: 1340px) 100vw, 1340px\" \/><\/a><\/figure>\n<\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-gallery aligncenter has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/discover.restek.com\/fr\/rmx\/\"><img loading=\"lazy\" decoding=\"async\" width=\"2040\" height=\"1976\" data-id=\"79859\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-FR.png\" alt=\"\" class=\"wp-image-79859\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-FR.png 2040w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-FR-300x291.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-FR-1024x992.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-FR-768x744.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-FR-1536x1488.png 1536w\" sizes=\"auto, (max-width: 2040px) 100vw, 2040px\" \/><\/a><\/figure>\n<\/figure>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Produits Mentionn\u00e9s<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/fr.restek.com\/p\/17323\">                                R\u00e9f. 17323                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Colonne capillaire GC RMX-5Sil MS, L 30 m, DI 0.25 mm, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/fr.restek.com\/p\/17323\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23267\">                                R\u00e9f. 23267                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Insert Topaz Precision, 4.0\u00a0mm x 6.3 x 78.5, pour GC Thermo TRACE 1300\/1310, 1600\/1610 avec injecteur SSL, avec laine de quartz, d\u00e9sactivation Premium, lot de 5<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23267\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">                                R\u00e9f. 28500                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">D\u00e9tecteur \u00e9lectronique de fuites de gaz Restek<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31907\">                                R\u00e9f. 31907                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Kit de solutions-\u00e9talons SVOC MegaMix 150, 1 ml\/ampoule ; 6 ampoules\/kit<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31907\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31025\">                                R\u00e9f. 31025                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Solution \u00e9talon de compos\u00e9s de substitution acides (4\/89 SOW), 2000 \u00b5g\/ml, m\u00e9thanol, ampoule de 1 ml<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31025\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31024\">                                R\u00e9f. 31024                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Solution \u00e9talon de compos\u00e9s de substitution basiques ou neutres (4\/89 SOW), 1000 \u00b5g\/ml, chlorure de m\u00e9thyl\u00e8ne, ampoule de 1 ml<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31024\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31886\">                                R\u00e9f. 31886                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">M\u00e9lange d\u2019\u00e9talons internes de SV r\u00e9vis\u00e9, 4000 \u00b5g\/ml, chlorure de m\u00e9thyl\u00e8ne, ampoule de 1\u00a0ml<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31886\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Optimisez la productivit\u00e9 de votre laboratoire gr\u00e2ce \u00e0 cette m\u00e9thode \u00e9tendue d&#8217;analyse des compos\u00e9s semi-volatils \u00e0 l&#8217;\u00e9tat de traces pour 150 analytes cibles. Tr\u00e8s efficaces, les colonnes RMX-5Sil MS vous aident \u00e0 r\u00e9pondre aux exigences de qualit\u00e9 jusqu&#8217;\u00e0 0,1 pg sur colonne pour une large gamme de compos\u00e9s semi-volatils difficiles \u00e0 analyser.<\/p>\n","protected":false},"author":34,"featured_media":62376,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[462],"tags":[2743],"industries-application":[2210,2208,2758,2213],"post-badge":[2759],"resource-type":[],"product-library":[2456,2444],"resource-technique":[2316,2362,2320],"ppma_author":[454,441,2657,452],"class_list":["post-80225","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-fr","tag-rmx-resources","industries-application-eau-potable-eaux-usees","industries-application-environnement","industries-application-semivolatiles","industries-application-sols-sediments-biote","post-badge-new","product-library-colonnes-gc","product-library-produits-pour-la-chromatographie-en-phase-gazeuse","resource-technique-chromatographie-en-phase-gazeuse-gc","resource-technique-ms-ms-fr","resource-technique-spectrometrie-de-masse-ms"],"acf":[],"taxonomy_info":{"category":[{"value":462,"label":"Articles"}],"post_tag":[{"value":2743,"label":"Ressources RMX"}],"industries-application":[{"value":2210,"label":"Eau potable et eaux us\u00e9es"},{"value":2208,"label":"Environnement"},{"value":2758,"label":"Semivolatiles"},{"value":2213,"label":"Sols, s\u00e9diments, biote"}],"post-badge":[{"value":2759,"label":"New"}],"product-library":[{"value":2456,"label":"Colonnes GC"},{"value":2444,"label":"Produits pour la chromatographie en phase gazeuse"}],"resource-technique":[{"value":2316,"label":"Chromatographie en phase gazeuse (GC)"},{"value":2362,"label":"MS\/MS"},{"value":2320,"label":"Spectrom\u00e9trie de masse (MS)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVFA5253-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Erica Pack, PhD","author_link":"https:\/\/discover.restek.com\/fr\/author\/erica-pack-phd\/"},"comment_info":0,"category_info":[{"term_id":462,"name":"Articles","slug":"articles-fr","term_group":0,"term_taxonomy_id":462,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":462,"category_count":510,"category_description":"","cat_name":"Articles","category_nicename":"articles-fr","category_parent":0}],"tag_info":[{"term_id":2743,"name":"Ressources RMX","slug":"rmx-resources","term_group":0,"term_taxonomy_id":2743,"taxonomy":"post_tag","description":"Explorez les ressources RMX","parent":0,"count":23,"filter":"raw"}],"authors":[{"term_id":454,"user_id":34,"is_guest":0,"slug":"erica-pack-phd","display_name":"Erica Pack, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg"},"author_category":"1","first_name":"Erica","last_name":"Pack","user_url":"https:\/\/www.linkedin.com\/in\/ericapack\/","job_title":"Senior Scientist, GC Applied","description":"Erica is an interdisciplinary GC applications and technologies scientist at Restek. She obtained her bachelor's degree in forensic biology from The Pennsylvania State University, and her doctorate from Virginia Tech in plant pathology, physiology, and weed science. Since joining Restek in 2021, she has worked with a wide variety of GC columns, including fused silica, MXT, PLOT, and packed columns as well as accessories, such as liners, valves, and methanizers."},{"term_id":441,"user_id":21,"is_guest":0,"slug":"chris-english","display_name":"Chris English","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-english-chris.png","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-english-chris.png"},"author_category":"1","first_name":"Chris","last_name":"English","user_url":"https:\/\/www.linkedin.com\/in\/chris-english-28214912\/","job_title":"Sr. R&D Manager","description":"Since 2004, Chris has managed a team of chemists in Restek's innovations laboratory who perform new product testing, method development, and applications work. Before taking the reins of our lab, he spent seven years as an environmental chemist and was critical to the development of Restek\u2019s current line of volatile GC columns. Prior to joining Restek, he operated a variety of gas chromatographic detectors conducting method development and sample analysis. Chris holds a BS in environmental science from Saint Michael's College."},{"term_id":2657,"user_id":70,"is_guest":0,"slug":"ramkumar-dhandapani-phd","display_name":"Ramkumar Dhandapani, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Dhandapani_Ramkumar_Profile.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Dhandapani_Ramkumar_Profile.jpg"},"author_category":"1","first_name":"Ramkumar","last_name":"Dhandapani","user_url":"https:\/\/www.linkedin.com\/in\/dr-ramkumar-dhandapani-b9012424\/?skipRedirect=true&enhance=null","job_title":"Director of Product Management","description":"Dr. Ramkumar Dhandapani\u00a0is a seasoned analytical chemist with over\u00a023 years of experience\u00a0in the chromatography industry and a Ph.D. in analytical chemistry. During his career, he has specialized in method development, validation, and the troubleshooting of chromatography methods. He has developed numerous regulatory-compliant methods across diverse sectors, including\u00a0environmental analysis, food quality and safety, pharmaceutical, fuels, and chemical industries. Currently, Dr. Dhandapani is the Director of Product Management at Restek, he is keen on innovation in chromatography and scaling breakthrough innovations\u00a0to market as commercial products."},{"term_id":452,"user_id":32,"is_guest":0,"slug":"colton-myers","display_name":"Colton Myers","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg"},"author_category":"1","first_name":"Colton","last_name":"Myers","user_url":"https:\/\/www.linkedin.com\/in\/myerscolton\/","job_title":"Product Manager - New Product Development","description":"Colton Myers is a Product Manager for GC columns at Restek Corporation with over 10 years of experience in research and development. He specializes in driving new GC column technologies from concept to market, combining deep technical expertise with a strong focus on innovation and commercialization. Colton holds a BS in chemistry from Juniata College and a Master of Management in Corporate Innovation and Entrepreneurship from Penn State University."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/80225","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/34"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=80225"}],"version-history":[{"count":40,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/80225\/revisions"}],"predecessor-version":[{"id":91754,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/80225\/revisions\/91754"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/62376"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=80225"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=80225"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=80225"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=80225"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=80225"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=80225"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=80225"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=80225"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=80225"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}