{"id":83940,"date":"2026-01-22T16:16:48","date_gmt":"2026-01-22T16:16:48","guid":{"rendered":"https:\/\/discover.restek.com\/?p=83940"},"modified":"2026-06-05T22:58:27","modified_gmt":"2026-06-05T22:58:27","slug":"analysis-of-furan-and-alkylfurans-in-food-commodities-using-headspace-spme-arrow-and-gc-ms","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/posters-presentations\/gnot5355\/analysis-of-furan-and-alkylfurans-in-food-commodities-using-headspace-spme-arrow-and-gc-ms","title":{"rendered":"Analysis of Furan and Alkylfurans in Food Commodities Using Headspace SPME Arrow and GC-MS"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>Furan and alkylfurans are produced during heating of foodstuff as a result of the thermal degradation of compounds such as carbohydrates, ascorbic acid, and derivatives, as well as some lipids.<\/li>\n\n\n\n<li>The International Agency for Research of Cancer classified furan as a possible carcinogenic compound, and there is a general concern on the possible health risks associated with the occurrence of furans and alkylfurans in food.<\/li>\n\n\n\n<li>Methods reported for the analysis of these volatile organic compounds include static headspace (HS) and solid phase microextraction (SPME) in combination with GC-MS.<\/li>\n\n\n\n<li>The use of SPME for the analysis of these highly volatile analytes has demonstrated improved method sensitivity and higher S\/N for some of the alkylfurans. However, the fragility of traditional SPME fibers can be a concern.<\/li>\n\n\n\n<li>In this work, we present a HS-SPME-GC-MS method for the analysis of furans and alkylfurans in baby formula and coffee using a SPME arrow<\/li>\n<\/ul>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/discover.restek.com\/wp-content\/uploads\/poster-rafa-2022-analysis-of-furan-and-alkylfurans-in-food-commodities.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"Embed of poster-rafa-2022-analysis-of-furan-and-alkylfurans-in-food-commodities.\"><\/object><a id=\"wp-block-file--media-cfae558f-e73e-4d78-9d0e-0d164285ae6b\" href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/poster-rafa-2022-analysis-of-furan-and-alkylfurans-in-food-commodities.pdf\">poster-rafa-2022-analysis-of-furan-and-alkylfurans-in-food-commodities<\/a><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/poster-rafa-2022-analysis-of-furan-and-alkylfurans-in-food-commodities.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-cfae558f-e73e-4d78-9d0e-0d164285ae6b\">Download<\/a><\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/discover.restek.com\/wp-content\/uploads\/presentation-rafa-2022-analysis-of-furan-and-alkylfurans-in-food-commodities.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"Embed of presentation-rafa-2022-analysis-of-furan-and-alkylfurans-in-food-commodities.\"><\/object><a id=\"wp-block-file--media-11f5d488-6a42-43b3-b276-869f4ed13a01\" href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/presentation-rafa-2022-analysis-of-furan-and-alkylfurans-in-food-commodities.pdf\">presentation-rafa-2022-analysis-of-furan-and-alkylfurans-in-food-commodities<\/a><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/presentation-rafa-2022-analysis-of-furan-and-alkylfurans-in-food-commodities.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-11f5d488-6a42-43b3-b276-869f4ed13a01\">Download<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[12],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[603],"class_list":["post-83940","post","type-post","status-publish","format-standard","hentry","category-posters-presentations"],"acf":[],"taxonomy_info":{"category":[{"value":12,"label":"Posters &amp; Presentations"}]},"featured_image_src_large":false,"author_info":{"display_name":"Patrick Gallagher","author_link":"https:\/\/discover.restek.com\/fr\/author\/patrick-gallagherrestek-com\/"},"comment_info":0,"category_info":[{"term_id":12,"name":"Posters &amp; Presentations","slug":"posters-presentations","term_group":0,"term_taxonomy_id":12,"taxonomy":"category","description":"","parent":0,"count":118,"filter":"raw","cat_ID":12,"category_count":118,"category_description":"","cat_name":"Posters &amp; Presentations","category_nicename":"posters-presentations","category_parent":0}],"tag_info":false,"authors":[{"term_id":603,"user_id":0,"is_guest":1,"slug":"nathaly-reyes-garces-phd","display_name":"Nathaly Reyes-Garc\u00e9s, PhD","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Nathaly","last_name":"Reyes-Garc\u00e9s","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/83940","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=83940"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/83940\/revisions"}],"predecessor-version":[{"id":83965,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/83940\/revisions\/83965"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=83940"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=83940"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=83940"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=83940"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=83940"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=83940"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=83940"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=83940"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=83940"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}