{"id":83994,"date":"2026-01-22T17:02:40","date_gmt":"2026-01-22T17:02:40","guid":{"rendered":"https:\/\/discover.restek.com\/?p=83994"},"modified":"2026-08-11T18:31:28","modified_gmt":"2026-08-11T18:31:28","slug":"consolidating-lc-ms-ms-method-conditions-for-the-analysis-of-alcohol-metabolites-barbiturates-and-drugs-of-abuse-2","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/posters-presentations\/gnot5358\/consolidating-lc-ms-ms-method-conditions-for-the-analysis-of-alcohol-metabolites-barbiturates-and-drugs-of-abuse-2","title":{"rendered":"Consolidating LC-MS\/MS Method Conditions for the Analysis of Alcohol Metabolites, Barbiturates, and Drugs of Abuse"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Efficiency is key when running multiple drug panels and any way to save time or streamline a process can help reduce costs. To help simplify the analysis of alcohol metabolites, barbiturates, and drugs of abuse, three different methods were developed for each analyte class using the same analytical column and mobile phase setup. A panel of 129 drug and drug metabolite isobars in positive mode, negative mode drug and drug metabolites, and alcohol metabolites were all analyzed using a Force Biphenyl 50 x 3 mm, 2.7 \u00b5m analytical column and 0.1% formic acid in water and 0.1% formic acid in methanol mobile phases. The Force Biphenyl phase has unique selectivity due to the pi-pi interactions for drugs and drug metabolites when compared to a routine C18 phase allowing for improved resolution of isobars. Urinary interferences that are particularly problematic in alcohol metabolite testing were resolved without the use of buffer or additional mobile phases helping to streamline analytical testing.<\/p>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/discover.restek.com\/wp-content\/uploads\/poster-soft-2022-consolidating-lcmsms-method-conditions-analysis-alcohol-metabolites-barbiturates-drugs-of-abuse.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"Embed of poster-soft-2022-consolidating-lcmsms-method-conditions-analysis-alcohol-metabolites-barbiturates--drugs-of-abuse.\"><\/object><a id=\"wp-block-file--media-c6912125-ff48-4a50-88d0-4e64cb68585c\" href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/poster-soft-2022-consolidating-lcmsms-method-conditions-analysis-alcohol-metabolites-barbiturates-drugs-of-abuse.pdf\">poster-soft-2022-consolidating-lcmsms-method-conditions-analysis-alcohol-metabolites-barbiturates&#8211;drugs-of-abuse<\/a><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/poster-soft-2022-consolidating-lcmsms-method-conditions-analysis-alcohol-metabolites-barbiturates-drugs-of-abuse.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-c6912125-ff48-4a50-88d0-4e64cb68585c\">Download<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Efficiency is key when running multiple drug panels and any way to save time or streamline a process can help reduce costs. To help simplify the analysis of alcohol metabolites, barbiturates, and drugs of abuse, three different methods were developed for each analyte class using the same analytical column and mobile phase setup. A panel&#8230;<\/p>\n","protected":false},"author":47,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[12],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[579],"class_list":["post-83994","post","type-post","status-publish","format-standard","hentry","category-posters-presentations"],"acf":[],"taxonomy_info":{"category":[{"value":12,"label":"Posters &amp; Presentations"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jamie L. York, PhD","author_link":"https:\/\/discover.restek.com\/fr\/author\/jamie-l-york-phd\/"},"comment_info":0,"category_info":[{"term_id":12,"name":"Posters &amp; Presentations","slug":"posters-presentations","term_group":0,"term_taxonomy_id":12,"taxonomy":"category","description":"","parent":0,"count":125,"filter":"raw","cat_ID":12,"category_count":125,"category_description":"","cat_name":"Posters &amp; Presentations","category_nicename":"posters-presentations","category_parent":0}],"tag_info":false,"authors":[{"term_id":579,"user_id":47,"is_guest":0,"slug":"jamie-l-york-phd","display_name":"Jamie L. York, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/york-jamie-1000x1000-1-e1765483005988.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/york-jamie-1000x1000-1-e1765483005988.jpg"},"author_category":"1","first_name":"Jamie","last_name":"York","user_url":"https:\/\/www.linkedin.com\/in\/jamielyork\/","job_title":"Principal Scientist, LC Solutions","description":"Jamie York is a principal scientist in the Applications Lab at Restek Corporation. She leads the development of innovative analytical methods tailored to the food, clinical, environmental, and cannabis markets. Jamie earned her PhD in chemistry from The University of Texas at Arlington, where she gained extensive expertise in a range of analytical techniques, including gas chromatography\u2013vacuum ultraviolet (GC\u2013VUV); gas chromatography\u2013mass spectrometry (GC\u2013MS); matrix-assisted laser desorption\/ionization (MALDI); and liquid chromatography\u2013 mass spectrometry (LC\u2013MS\/MS); with a research emphasis on food and environmental analysis. Today, her work focuses on complex method development and advanced sample preparation strategies to support the evolving needs of the scientific community."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/83994","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/47"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=83994"}],"version-history":[{"count":1,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/83994\/revisions"}],"predecessor-version":[{"id":83998,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/83994\/revisions\/83998"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=83994"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=83994"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=83994"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=83994"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=83994"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=83994"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=83994"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=83994"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=83994"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}