{"id":98792,"date":"2026-07-20T15:14:48","date_gmt":"2026-07-20T15:14:48","guid":{"rendered":"https:\/\/discover.restek.com\/?p=98792"},"modified":"2026-08-25T14:04:50","modified_gmt":"2026-08-25T14:04:50","slug":"adapting-epa-525-2-and-8270-gc-methods-to-the-methylene-chloride-ban-using-the-rmx-5sil-ms-column","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/fr\/articles\/evbl5595\/adapting-epa-525-2-and-8270-gc-methods-to-the-methylene-chloride-ban-using-the-rmx-5sil-ms-column","title":{"rendered":"Adapting EPA 525.2 and 8270 GC Methods to the Methylene Chloride Ban Using the RMX-5Sil MS Column"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"2160\" height=\"450\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/feature-evbl5595.jpg\" alt=\"\" class=\"wp-image-100507\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/feature-evbl5595.jpg 2160w, https:\/\/discover.restek.com\/wp-content\/uploads\/feature-evbl5595-300x63.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/feature-evbl5595-1024x213.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/feature-evbl5595-768x160.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/feature-evbl5595-1536x320.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/feature-evbl5595-2048x427.jpg 2048w\" sizes=\"auto, (max-width: 2160px) 100vw, 2160px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>If your lab runs EPA 525.2 or EPA 8270, you&#8217;re likely already navigating the operational and compliance challenges that come with the near-total ban on methylene chloride (DCM) under the Toxic Substances Control Act. Both methods were developed with DCM as the primary extraction solvent, and direct substitution isn&#8217;t generally permitted within the existing method frameworks, so finding a workable path forward takes some thought. Restek&#8217;s Director of GC Product Management, Ramkumar Dhandapani, sat down with Eduardo Morales at Weck Laboratories, Inc., to talk through a practical approach to this transition.<\/em><\/p>\n\n\n\n<div class=\"wp-block-group has-theme-palette-7-background-color has-background\" style=\"border-top-left-radius:10px;border-top-right-radius:10px;border-bottom-left-radius:10px;border-bottom-right-radius:10px;min-height:0px;padding-top:0.4rem;padding-right:var(--wp--preset--spacing--30);padding-bottom:0.4rem;padding-left:var(--wp--preset--spacing--30)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-container-core-group-is-layout-eeeda704 wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-bottom is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<p class=\"has-text-align-right wp-block-paragraph\" style=\"font-size:20px\"><strong><em>&#8220;RMX-5Sil MS preserves performance when reduced DCM leaves less room for compromise.&#8221;<\/em><\/strong><\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-text-align-right has-text-color has-link-color wp-elements-f834d55d594e34ec18136d36f7a7e0c1 wp-block-paragraph\" style=\"color:#a71a32\"><strong>Ramkumar Dandapani, PhD<br><\/strong>Director of Product Management<br>Restek Corporation<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"402\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-01.png\" alt=\"\" class=\"wp-image-99991\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-01.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-01-300x157.png 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-bottom is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:25%\">\n<p class=\"has-text-align-left wp-block-paragraph\" style=\"font-size:20px\"><strong><em>&#8220;As DCM use decreases, RMX-5Sil MS helps maintain the sensitivity and resolution labs depend on.&#8221;<\/em><\/strong><\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-fe23e7305d18232c6c7685d0ecf7e48e wp-block-paragraph\" style=\"color:#0a2773\"><strong>Eduardo Morales<br><\/strong>Environmental Scientist<br>Weck Laboratories, Inc.<\/p>\n<\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group\" style=\"border-left-color:#888780;border-left-width:4px;padding-left:var(--wp--preset--spacing--40)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-container-core-group-is-layout-ca1f2c93 wp-block-group-is-layout-constrained\">\n<p class=\"has-text-color has-link-color wp-elements-47c33aa56385ca0395ca8682d8fe5618 wp-block-paragraph\" style=\"color:#a71a32\"><strong>Ramkumar: <em>To start, what approach did you and Restek take to evaluate a path through this transition?<\/em><\/strong><\/p>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-275cbf8e3777ec293aa8393804c905af wp-block-paragraph\" style=\"color:#0a2773\"><strong>Eduardo: <\/strong>Working with Restek&#8217;s applications team, we evaluated the RMX-5Sil MS column (<a href=\"https:\/\/www.restek.com\/p\/17323\" target=\"_blank\" rel=\"noopener\">cat.# 17323<\/a>) under both EPA 525.2 (GC\/MS) and EPA 8270 (GC-MS\/MS) conditions to see how well it supports one of the most practical adaptation strategies available: <strong>reducing solvent and sample volumes proportionally to limit DCM use while staying within established method parameters.<\/strong><\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group\" style=\"border-left-color:#888780;border-left-width:4px;padding-left:var(--wp--preset--spacing--40)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-container-core-group-is-layout-ca1f2c93 wp-block-group-is-layout-constrained\">\n<p class=\"has-text-color has-link-color wp-elements-ffe1849a52a60b020466b3d94b50d07f wp-block-paragraph\" style=\"color:#a71a32\"><strong>Ramkumar: <em>Why has methylene chloride been so difficult to replace in these methods?<\/em><\/strong><\/p>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-eb4aa996b38e4fd87bcf48e543c5e05a wp-block-paragraph\" style=\"color:#0a2773\"><strong>Eduardo: <\/strong>Methylene chloride became the default extraction solvent for semivolatile methods because it genuinely performs well across a broad range of compound classes\u2014PAHs, phenols, pesticides, phthalates, nitroaromatics. EPA 525.2 and 8270 were both built around <strong>fixed solvent-to-sample ratios that assume routine DCM use<\/strong>, which is a significant part of what makes adapting these methods so challenging.<\/p>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-41642e58504f9897708ba5668fa8578d wp-block-paragraph\" style=\"color:#0a2773\">The health hazards associated with DCM are well established: <strong>central nervous system depression, acute inhalation toxicity, potential carcinogenicity, and organ toxicity with repeated exposure.<\/strong> The TSCA restrictions reflect those concerns, and they&#8217;ve added real compliance, documentation, and operational costs on top of the analytical challenge. Because direct solvent substitution isn&#8217;t permitted under these methods, <strong>reducing DCM volume\u2014while maintaining the required phase ratio by scaling sample volume accordingly\u2014is the most feasible option for most labs.<\/strong><\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group\" style=\"border-left-color:#888780;border-left-width:4px;padding-left:var(--wp--preset--spacing--40)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-container-core-group-is-layout-ca1f2c93 wp-block-group-is-layout-constrained\">\n<p class=\"has-text-color has-link-color wp-elements-ad32307e15d7a4b84a7c6aa6896b1308 wp-block-paragraph\" style=\"color:#a71a32\"><strong>Ramkumar: <em>What&#8217;s the analytical trade-off when a lab reduces solvent volume that way?<\/em><\/strong><\/p>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-c46de641dfef8071e5a4d3939435d489 wp-block-paragraph\" style=\"color:#0a2773\"><strong>Eduardo: <\/strong>That proportional reduction in sample and solvent volume comes with a direct analytical consequence: <strong>less total analyte mass reaching the detector.<\/strong> For methods that are already operating at trace levels, this places <strong>greater demands on chromatographic sensitivity, peak shape, and column inertness.<\/strong> The column, in other words, has to work harder to compensate for what&#8217;s been lost in the extraction step. This is the core challenge the RMX-5Sil MS was evaluated against.<\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group\" style=\"border-left-color:#888780;border-left-width:4px;padding-left:var(--wp--preset--spacing--40)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-container-core-group-is-layout-ca1f2c93 wp-block-group-is-layout-constrained\">\n<p class=\"has-text-color has-link-color wp-elements-0599da3e83e9a99228f4bb2123dfba65 wp-block-paragraph\" style=\"color:#a71a32\"><strong>Ramkumar: <em>Walk me through what you actually tested.<\/em><\/strong><\/p>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-27a08f6c171843ba05d1a94abe90e315 wp-block-paragraph\" style=\"color:#0a2773\"><strong>Eduardo: <\/strong>Working with Restek&#8217;s applications team, we ran <strong>approximately 90 analytes across both methods<\/strong>, covering PAHs, pesticides, phenols, phthalates, and nitroaromatics.<\/p>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-c9d508fc3a624b400c2c6dc534aaab1d wp-block-paragraph\" style=\"color:#0a2773\">The column under evaluation, the RMX-5Sil MS (<a href=\"https:\/\/www.restek.com\/p\/17323\" target=\"_blank\" rel=\"noopener\">cat.# 17323<\/a>), is part of Restek&#8217;s RMX GC column family and incorporates <strong>TriMax deactivation technology<\/strong>, a three-dimensional bonding and cross-linking approach engineered for <strong>enhanced inertness across acids, bases, and neutral compounds with low thermal bleed.<\/strong> Those characteristics make it particularly well suited to the demands of reduced-volume extractions, where sensitivity and inertness have less margin for compromise. The Topaz 4 mm Precision inlet liner with wool (<a href=\"https:\/\/www.restek.com\/p\/23305\" target=\"_blank\" rel=\"noopener\">cat.# 23305<\/a>) was used throughout to complement the column&#8217;s inertness for active compound classes.<\/p>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-1b0cd773837eb7d7c060013cbca32053 wp-block-paragraph\" style=\"color:#0a2773\">EPA Method 525.2 was run on a single quadrupole GC\/MS platform, where we focused on <strong>long-term robustness, baseline stability, and column durability<\/strong> over extended injection sequences. EPA Method 8270 was run on a triple quadrupole GC-MS\/MS platform, where the emphasis was on <strong>sensitivity, low-level performance, and resolution of critical semivolatile analytes.<\/strong><\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group\" style=\"border-left-color:#888780;border-left-width:4px;padding-left:var(--wp--preset--spacing--40)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-container-core-group-is-layout-ca1f2c93 wp-block-group-is-layout-constrained\">\n<p class=\"has-text-color has-link-color wp-elements-4c1efc424f573a6d427ec994b5c434aa wp-block-paragraph\" style=\"color:#a71a32\"><strong>Ramkumar: <em>What did you find regarding baseline stability under EPA 525.2?<\/em><\/strong><\/p>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-f3881028dd0a5403216eb3be1794f11e wp-block-paragraph\" style=\"color:#0a2773\"><strong>Eduardo: <\/strong>EPA 525.2 and 8270 both require elevated final oven temperatures to fully elute late-eluting PAHs and other semivolatiles, and column bleed at those temperatures is a real concern. Elevated bleed raises the baseline, degrades signal-to-noise ratios, and contributes to ion source contamination over time.<\/p>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-a86beb632a83fa52b4b4138f65f23a46 wp-block-paragraph\" style=\"color:#0a2773\">The RMX-5Sil MS showed <strong>significantly lower thermal bleed<\/strong> compared to the traditional 5-type MS column under EPA 525.2 GC\/MS conditions. The cleaner baselines translated directly into <strong>improved signal-to-noise ratios at elevated temperatures<\/strong>, which matters even more when reduced extraction volumes are already limiting the analyte mass available for detection.<\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"425\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-02-1024x425.jpg\" alt=\"\" class=\"has-border-color wp-image-99965\" style=\"border-color:#cccccc;border-width:1px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-02-1024x425.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-02-300x124.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-02-768x319.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-02.jpg 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><em>Comparison of chromatograms highlighting reduced thermal bleed and cleaner baselines observed with the RMX-5Sil MS column versus a traditional column.<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group\" style=\"border-left-color:#888780;border-left-width:4px;padding-left:var(--wp--preset--spacing--40)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-container-core-group-is-layout-ca1f2c93 wp-block-group-is-layout-constrained\">\n<p class=\"has-text-color has-link-color wp-elements-7a9abf75c60561ac9ec81c7942bd8d28 wp-block-paragraph\" style=\"color:#a71a32\"><strong>Ramkumar: <em>And what about resolution of critical analyte pairs under EPA 8270?<\/em><\/strong><\/p>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-32112382e9aad36fbf5c7e466c0691c1 wp-block-paragraph\" style=\"color:#0a2773\"><strong>Eduardo: <\/strong>Reliable separation of isomeric compounds is a fundamental requirement for EPA semivolatile methods, and separation of benzo(b)fluoranthene and benzo(k)fluoranthene is one of the most closely watched performance indicators in EPA 8270 workflows. It&#8217;s often one of the first things to degrade as a column ages.<\/p>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-ff2afc15d3721a0bef0814b98d5679f2 wp-block-paragraph\" style=\"color:#0a2773\">Under EPA 8270 GC-MS\/MS conditions, the RMX-5Sil MS provided <strong>improved and sustained resolution <\/strong>of benzo(b)fluoranthene and benzo(k)fluoranthene<strong>, including after extended use.<\/strong> Resolution of indeno[1,2,3-cd]pyrene and dibenzo[a,h]anthracene was similarly improved along with additional critical analyte pairs across the 8270 target compound list. Beyond baseline stability, the RMX-5Sil MS also delivered meaningful improvements in peak resolution under EPA 8270 GC-MS\/MS conditions. Sustained resolution over hundreds of injections means <strong>fewer column changes, fewer recalibrations, and less downtime<\/strong>\u2014all of which matter when labs are already managing the added complexity of a DCM transition.<\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"425\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-03-1024x425.jpg\" alt=\"\" class=\"wp-image-99960\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-03-1024x425.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-03-300x124.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-03-768x319.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-03.jpg 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><em>Resolution comparison of benzo(b)fluoranthene and benzo(k)fluoranthene using the RMX-5Sil MS column and a traditional column, including performance after extended use.<\/em><\/figcaption><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"459\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-04-1024x459.jpg\" alt=\"\" class=\"wp-image-99961\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-04-1024x459.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-04-300x134.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-04-768x344.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-04.jpg 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Chromatographic resolution on the RMX-5Sil MS (left) vs. a traditional GC\/MS column (right): the critical indeno[1,2,3-cd]pyrene\/dibenzo[a,h]anthracene pair (top) and dimethoate at 0.05 ppm (bottom). <strong>The RMX-5Sil MS delivers cleaner peak shape and better resolution at trace levels.<\/strong><\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group\" style=\"border-left-color:#888780;border-left-width:4px;padding-left:var(--wp--preset--spacing--40)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-container-core-group-is-layout-ca1f2c93 wp-block-group-is-layout-constrained\">\n<p class=\"has-text-color has-link-color wp-elements-dbf7bdb6761aba9823b73add4353426a wp-block-paragraph\" style=\"color:#a71a32\"><strong>Ramkumar: <em>How did the column perform on sensitivity and linearity at trace levels?<\/em><\/strong><\/p>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-410574e759302825cb0c600d51e912a6 wp-block-paragraph\" style=\"color:#0a2773\"><strong>Eduardo: <\/strong>Under EPA 8270 GC-MS\/MS conditions, where reduced extraction volumes make sensitivity most critical, the RMX-5Sil MS delivered <strong>narrower peak widths and more consistent peak shape<\/strong>, which contributed to improved signal-to-noise ratios at low concentrations. Low-level calibration standards at 10 ppb and below produced <strong>consistent responses with minimal background interference<\/strong>, and calibration curves demonstrated <strong>good linearity across the working range.<\/strong><\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"425\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-05-1024x425.jpg\" alt=\"\" class=\"wp-image-99962\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-05-1024x425.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-05-300x124.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-05-768x319.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-05.jpg 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><em>Calibration curves and representative chromatograms demonstrating improved sensitivity and linearity at low concentrations using the RMX-5Sil MS column.<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group\" style=\"border-left-color:#888780;border-left-width:4px;padding-left:var(--wp--preset--spacing--40)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-container-core-group-is-layout-ca1f2c93 wp-block-group-is-layout-constrained\">\n<p class=\"has-text-color has-link-color wp-elements-a99eb0a8c46dce64529fa07de9623697 wp-block-paragraph\" style=\"color:#a71a32\"><strong>Ramkumar: <em>Does that performance hold up over time and across a large sample set?<\/em><\/strong><\/p>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-506a25993768712e4398c141e22ec33e wp-block-paragraph\" style=\"color:#0a2773\"><strong>Eduardo: <\/strong>Routine drinking water analysis under EPA 525.2 requires consistent performance across extended injection sequences, and column drift or loss of inertness translates directly into downtime and recalibration. This is especially relevant when labs are already managing the operational complexity of scaling down extraction volumes. Any instability in the chromatographic system compounds an already demanding transition.<\/p>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-8c8cf5650d68b461d3a869244e83d348 wp-block-paragraph\" style=\"color:#0a2773\">Recovery data at low- and mid-level concentrations remained consistent over extended use with the RMX-5Sil MS column. The chromatograms below show the column maintaining reliable sensitivity at concentrations well below standard method levels\u2014<strong>20x lower at 50 ppb and 100x lower at 10 ppb<\/strong>\u2014across an extended sequence of injections.<\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"425\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-06-1024x425.jpg\" alt=\"\" class=\"wp-image-99963\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-06-1024x425.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-06-300x124.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-06-768x319.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-06.jpg 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><em>EPA 8270 GC-MS\/MS chromatograms acquired at 50 ppb and 10 ppb using the RMX-5Sil MS column, demonstrating reliable sensitivity at concentrations 20x and 100x below standard method levels.<\/em><\/figcaption><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"448\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-07-1024x448.jpg\" alt=\"\" class=\"wp-image-99964\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-07-1024x448.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-07-300x131.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-07-768x336.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-blog-evbl5595-07.jpg 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><em>PAH recovery data tracked over a 12-month period across more than 200 injections and 1000 environmental samples, demonstrating consistent RMX-5Sil MS column performance and minimal signal drift over extended use.<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group\" style=\"border-left-color:#888780;border-left-width:4px;padding-left:var(--wp--preset--spacing--40)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-container-core-group-is-layout-ca1f2c93 wp-block-group-is-layout-constrained\">\n<p class=\"has-text-color has-link-color wp-elements-43ec026abde9b112d7c7e48f9515cf4c wp-block-paragraph\" style=\"color:#a71a32\"><strong>Ramkumar: <em>To close, what&#8217;s your overall takeaway for labs navigating this transition?<\/em><\/strong><\/p>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-33025478821ee190387e7280344cd77f wp-block-paragraph\" style=\"color:#0a2773\"><strong>Eduardo: <\/strong>Reducing methylene chloride and sample volumes is currently <strong>the most practical approach for laboratories adapting EPA 525.2 and 8270 to the TSCA restrictions.<\/strong> It avoids method redevelopment while bringing DCM use into compliance. The trade-off is reduced analyte mass, and that places real demands on the chromatographic system.<\/p>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-965f1dba8a4f468a47753a4c776d461f wp-block-paragraph\" style=\"color:#0a2773\">In this work with Restek, the RMX-5Sil MS column demonstrated <strong>low bleed, sustained resolution; trace-level sensitivity; and long-term robustness<\/strong> across both platforms with GC-MS\/MS conditions under EPA 8270 highlighting particularly strong gains in sensitivity and critical analyte resolution at low concentrations. I recommend <strong>evaluating your column and inlet liner setup early in this transition.<\/strong> Chromatographic performance is often the limiting factor when extraction volumes are scaled down, and it&#8217;s one of the more straightforward variables to address.<\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:5px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><em>For foundational performance data on the RMX-5Sil MS under optimized EPA 8270E GC-MS\/MS conditions, see Restek&#8217;s <\/em><a href=\"https:\/\/discover.restek.com\/application-notes\/evan4919\/comprehensive-trace-level-gc-ms-ms-semivolatiles-method-epa-method-8270e\"><em>Trace-Level Semivolatiles application note<\/em><\/a><em>.<\/em><\/p>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Produits mentionn\u00e9s<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/fr.restek.com\/p\/17323\">                                R\u00e9f. 17323                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Colonne capillaire GC RMX-5Sil MS, L 30 m, DI 0.25 mm, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/fr.restek.com\/p\/17323\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23305\">                                R\u00e9f. 23305                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Insert Topaz Precision, 4.0\u00a0mm x 6.3 x 78.5, pour GC Agilent, avec laine de quartz, d\u00e9sactivation Premium, lot de 5<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23305\">Voir le produit<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        ","protected":false},"excerpt":{"rendered":"<p>The near-total ban on methylene chloride under TSCA has created real operational challenges for labs running EPA 525.2 and 8270. Here&#8217;s how the RMX-5Sil MS column helps maintain trace-level performance when extraction volumes are scaled down.<\/p>\n","protected":false},"author":11,"featured_media":99990,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[7],"tags":[],"industries-application":[2163,2161],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2294,2301,2302],"ppma_author":[414],"class_list":["post-98792","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles","industries-application-drinking-water-wastewater-testing","industries-application-environmental","resource-technique-gas-chromatography-gc","resource-technique-mass-spectrometry-ms","resource-technique-ms-ms"],"acf":[],"taxonomy_info":{"category":[{"value":7,"label":"Articles"}],"industries-application":[{"value":2163,"label":"Drinking Water &amp; Wastewater Testing"},{"value":2161,"label":"Environmental"}],"resource-technique":[{"value":2294,"label":"Gas Chromatography (GC)"},{"value":2301,"label":"Mass Spectrometry (MS)"},{"value":2302,"label":"MS\/MS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-blog-evbl5595.jpg",768,402,false],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/fr\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":492,"filter":"raw","cat_ID":7,"category_count":492,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/98792","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/comments?post=98792"}],"version-history":[{"count":47,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/98792\/revisions"}],"predecessor-version":[{"id":103573,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/posts\/98792\/revisions\/103573"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media\/99990"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/media?parent=98792"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/categories?post=98792"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/tags?post=98792"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/industries-application?post=98792"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/post-badge?post=98792"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-type?post=98792"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/product-library?post=98792"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/resource-technique?post=98792"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/fr\/wp-json\/wp\/v2\/ppma_author?post=98792"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}